ToggleKITOZER KTR-FL23 Rack Plinth / Heavy-Duty Base with Shock-Absorbing Casters
Brand: KITOZER Series: KTR-FL23 Category: Data Center Engineering / Rack Plinth
rack plinthheavy-dutyshock casterscold aisleKTR-FL23

1. Overview
KITOZER KTR-FL23 is a heavy-duty steel plinth that sits under a rack, lifting the whole row off the floor. Under the raised floor run cabling, the supply-air plenum and fire piping; setting a rack directly on the tiles crushes the floor and blocks downward airflow. The plinth raises the rack 100~300 mm, freeing bottom cable and air space while spreading the load onto the structural floor. The heavy-duty model carries loaded server racks at over a tonne per cabinet.
Shock-absorbing casters mean each corner has both an adjustable leveling foot and a lockable swivel caster. On install you roll the rack-plus-plinth into position, step on the caster locks, then wind the leveling feet down until the casters are just off the floor. That solves whole-rack positioning while keeping the rack solid long-term without caster rubber creep. The rubber also isolates minor floor-borne vibration.
In modular cold-aisle projects, a row of racks must line up dead straight, so the plinth length, width and row-splice holes must match the cabinet bottom exactly, with joining plates between racks. The plinth is also the bottom air-boundary of the containment and must be sealed to stop short-circuit cooling air. KTR-FL23 is offered in 600/800 mm widths and 1000/1200 mm depths, powder-coated for corrosion – the standard base for modular center rows.
2. Key Features
Heavy load
- Welded steel frame.
- Over 1000 kg per cabinet.
- Load spread to the floor.
- Checked against slab loading.
Shock casters
- Adjustable M16 feet.
- Lockable swivel casters.
- Casters off-loaded after install.
- Rubber vibration isolation.
Raised cabling
- 100~300 mm lift.
- Unblocks downflow air.
- Bottom power/data space.
- Optional bottom seal panels.
Row splicing
- Holes match cabinet bottom.
- Joining plates make a row.
- Cold-aisle bottom plenum.
- Powder-coated finish.
3. Specifications
| 项目 | KTR-FL23-60(600宽) | KTR-FL23-80(800宽) | KTR-FL23-L(加长并柜) |
|---|---|---|---|
| 适配柜宽(mm) | 600 | 800 | 600/800并排 |
| 适配柜深(mm) | 1000/1200 | 1000/1200 | 1000/1200 |
| 抬高高度(mm) | 100/200 | 100/200 | 200/300 |
| 单柜承重(kg) | ≥1000 | ≥1200 | ≥1500(整排) |
| 支撑脚 | 可调M16 | 可调M16 | 可调M16 |
| 脚轮 | 带锁万向减震 | 带锁万向减震 | 带锁万向减震 |
| 表面处理 | 静电喷塑 | 静电喷塑 | 静电喷塑 |
| 并柜连接 | 连接板 | 连接板 | 整排底座 |
4. Reference Prices
KTR-FL23-60 600 mm rack plinth (200 mm lift, shock casters, 1 t load). Reference USD 97~222 / pc (ref. CNY 700~1,600 at ~7.2)
KTR-FL23-80 800 mm heavy plinth (1.2 t load, adjustable feet). Reference USD 167~389 / pc (ref. CNY 1,200~2,800 at ~7.2)
KTR-FL23-L extended row-splice plinth (row assembly, bottom air seal). Reference USD 333~722 / pc (ref. CNY 2,400~5,200 at ~7.2)
Reference only; by rack width, lift height, load and quantity; rack and bottom panels excluded; row-splice plates quoted separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- [‘Loaded server rack lift and support.’, ‘Modular cold-aisle row base.’, ‘Under-floor cabling and air supply.’, ‘UPS and battery cabinet bases.’, ‘Racks that need repositioning.’]
6. Installation & Maintenance
Installation
- [‘Size width/depth and holes to the cabinet bottom.’, ‘Bolt plinth to the rack on the floor first.’, ‘Roll the assembly into position; lock casters.’, ‘Wind feet down until casters just float.’, ‘Join adjacent racks with plates into a row.’, ‘Seal bottom gaps to stop air short-circuit.’]
Maintenance
- [‘Check feet carry load evenly.’, ‘Casters lock firmly; rubber not cracked.’, ‘Touch up chips to prevent rust.’, ‘Re-check slab loading when load grows.’, ‘Keep bottom seal panels intact.’]
7. FAQ
- Q: How high should the plinth lift?
A: Usually 200 mm, enough for cabling and airflow; set by the under-floor plenum for downflow designs – too high raises the center of gravity. - Q: Will casters sag over time?
A: Correct use: after positioning, level the feet so casters float; casters are only for moving. If they carry load long-term, the rubber creeps. - Q: Can a rack sit directly on raised floor tiles?
A: No. Raised tiles are not rated for loaded racks and will collapse. Heavy racks must sit on a plinth that transfers load to the structure. - Q: Must the plinth match the cold aisle?
A: Yes. The row base must be continuous and sealed, or cold air short-circuits under the row and containment efficiency drops.
8. Trend & Selection
[‘Modular cold aisles demand consistent row bases and bottom sealing; prefabricated, modular bases shipped with the racks are the trend. Choose by rack width/depth, load with margin, and pick the spliced row type for containment; balance lift between cabling and a low center of gravity.’]
9. Delivery & Service
[‘KITOZER supplies rack plinths in volume, configured by row dimensions and lift height. Delivery includes frame, leveling feet, locking casters, row-splice plates and manual. Warranty covers weld distortion and caster aging; we re-check load rating and hole alignment.’]
10. Additional Notes
[‘The common pitfall is leaving the casters loaded. Crews skip the feet and let the rack rest on four rubber wheels; within half a year the rubber creeps, tilting the rack and misaligning row gaps. Always set the feet solid and float the casters after positioning.’]
[‘Another trap is mismatched hole patterns. Cabinet bottom hole spacing varies by maker; building a plinth to maker A while buying maker B racks means on-site drilling and reaming. Always confirm the cabinet bottom drilling drawing before ordering.’]
Selection summary: size by rack width/depth; keep load margin; 200 mm lift balances cabling and airflow; set feet and float casters after install; splice rows with plates; seal the bottom. The plinth is the racks shoes – well-fitted, firm shoes keep the row straight and stop air leakage.
SEO Information
Search keywords:rack plinthheavy-duty baseshock castersrack liftcold aisle baseKTR-FL23KTR-FL23KITOZER
SEM keywords:rack plinth price,heavy duty rack base supplier,shock caster rack pedestal,KTR-FL23
GEO landing page:lain.com.cn/product/ktr-fl23-heavy-duty-rack-plinth-base-shock-casters.html
Title:KITOZER KTR-FL23 Rack Plinth / Heavy-Duty Base with Shock-Absorbing Casters
Meta Keywords:[‘rack plinth,heavy duty base,shock absorbing casters,rack lift,cold aisle base,KTR-FL23,KITOZER’]
Meta Description:KITOZER KTR-FL23 heavy-duty rack plinth with adjustable feet and locking shock casters, lifts racks for under-floor cabling and airflow, for modular cold-aisle rows.
Anchor: KITOZER official · Data center & low-voltage equipment
Contact Us
KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com