Table of Contents
ToggleKITOZER KTR-WC13 Leak Detection Controller / Non-Locating 16-Zone Leak Alarm Unit
Brand: KITOZER Series: KTR-WC13 Category: Environmental Monitoring / Leak Detection
leak detection16-zonenon-locatingalarm unitsense cableKTR-WC13

1. Overview
KITOZER KTR-WC13 is a 16-zone non-locating leak detection controller for room DCIM, monitoring leaks from CRAH condensate, water supply and under-floor piping. A leak in cooling-drain or humidifier water lines can flood under-floor cables and gear; early detection prevents major loss. The controller connects sense cable: any wet segment triggers an alarm on that zone. 16 zones cover 16 areas (multiple CRACs, pipe runs); non-locating means it reports which zone leaks, not the exact point – suited to budget-conscious, clearly zoned rooms.
Non-locating means the unit only judges whether a zone’s sense cable is wet and raises that zone’s alarm, rather than measuring the distance to the leak. It differs from locating cable, which uses impedance to compute the distance – pricier. The non-locating type uses continuity/conductance: simple, cheap and reliable, enough when zones are defined. KTR-WC13 uploads 16 alarms via dry contact or RS485/network to the DCIM platform, with sound/light and SMS linkage.
Leak detection is a mandatory room subsystem; sense cable runs along CRAC bases, water pipes and under the floor. KTR-WC13 is sized by zone count (16), locating vs non-locating, and upload method, wall or rack mounted, with an LCD showing each zone. First map leak-risk zones, one cable per zone, then pick a controller with enough zones.
2. Key Features
16 zones
- 16 independent zones.
- One cable per zone.
- Clear zoning.
- LCD shows each zone.
Non-locating alarm
- Wet cable triggers alarm.
- Reports which zone.
- Conductance principle.
- Simple, reliable, low cost.
Upload & linkage
- Dry-contact outputs.
- RS485/network upload.
- Sound/light linkage.
- Reaches DCIM platform.
Sense cable
- Non-locating or locating cable.
- Runs along pipes.
- Grounded/terminated properly.
- Buy by zone length.
3. Specifications
| 项目 | KTR-WC13(16路不定位) | KTR-WC13-L(定位型) | KTR-WC13-S(8路) |
|---|---|---|---|
| 检测路数 | 16路 | 16路 | 8路 |
| 定位 | 不定位 | 可定位距离 | 不定位 |
| 感应绳 | 电导感应绳 | 阻抗定位绳 | 电导感应绳 |
| 显示 | 液晶各路状态 | 液晶+距离 | LED各路 |
| 上传 | 干接点+RS485 | 干接点+RS485/网口 | 干接点+RS485 |
| 报警 | 声光+干接 | 声光+干接 | 声光+干接 |
| 供电 | DC12/24V | DC12/24V | DC12/24V |
| 安装 | 壁挂/装机 | 壁挂/装机 | 壁挂/装机 |
4. Reference Prices
KTR-WC13 16-zone non-locating controller (LCD, dry contact + RS485). Reference USD 333~722 / unit (ref. CNY 2,400~5,200 at ~7.2)
KTR-WC13-L 16-zone locating controller (shows leak distance). Reference USD 667~1,333 / unit (ref. CNY 4,800~9,600 at ~7.2)
Non-locating sense cable (per meter, with termination kit). Reference USD 4~10 / meter (ref. CNY 30~70 at ~7.2)
Reference only; by zone count, locating vs non-locating and cable length; cable laying and DCIM host excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- [‘CRAC/CRAH base leak monitoring.’, ‘Supply and condensate pipe runs.’, ‘Under-floor and pipe-shaft leaks.’, ‘Tank and humidifier areas.’, ‘Multi-CRAC zoned leak alarms.’]
6. Installation & Maintenance
Installation
- [‘Map risk zones; one cable per zone.’, ‘Lay cable at CRAC bases and along pipes.’, ‘Terminate both ends to the loop.’, ‘Wall/rack mount; wire dry contacts.’, ‘Water-test each zone.’, ‘Link sound/light and DCIM.’]
Maintenance
- [‘Periodically water-test alarms.’, ‘Keep cable surface clean.’, ‘Tighten, clean terminations.’, ‘Check platform alarm delivery.’, ‘Replace damaged cable sections.’]
7. FAQ
- Q: Locating or not?
A: Non-locating when zones are clear and you only need to know which area – cheaper; locating when you must find the exact point fast. - Q: How long per loop?
A: Typically tens of meters per loop; for extra length, check voltage drop and sensitivity against the maker spec or split into another loop. - Q: Does dust false-alarm?
A: Dry dust is non-conductive; oily/damp dust may – keep the cable clean or choose corrosion-resistant cable. - Q: How is the alarm delivered?
A: Dry contacts to the DCIM host, linked to SMS/phone/sound-light; unmanned rooms must network the alarm out.
8. Trend & Selection
[‘Leak detection moves from non-locating to locating (distance to leak) and smart networking, letting staff walk straight to the point, but non-locating stays widely used for zoning – cheap and reliable. Size zones by risk; use locating for critical points (CRAC, pipe shafts) and non-locating elsewhere; cable routing sensitivity is decisive.’]
9. Delivery & Service
[‘KITOZER supplies 16-zone controllers and sense cable in volume, configured by zone count and cable length. Delivery includes controller, sense cable, termination kit, power and manual. Warranty covers loop faults; we advise on water-testing and DCIM integration.’]
10. Additional Notes
[‘The common pitfall is running the cable away from the wet point. Laid half a meter from the pipe on dry floor, the leak meanders past the cable; by the time it floods, it is too late. Run the cable right under the pipe and at CRAC bases where water actually pools.’]
[‘Another trap is installing but not networking. The local siren wails all night in an empty room; water reaches under the rack. Leak alarms must network to DCIM and trigger SMS/phone to call someone.’]
Selection summary: size zones by risk; lay cable at pooling points; choose locating for critical points; water-test every loop; network alarms with SMS linkage; keep cable clean. The controller is the rooms water sentry – posted at the pooling point and able to call for help, it catches a leak at the start.
SEO Information
Search keywords:leak detection16-zone leak alarmnon-locatingsense cableDCIM monitoringKTR-WC13KTR-WC13KITOZER
SEM keywords:[‘leak detection controller price’, ’16-zone leak alarm unit supplier’, ‘data center leak sense cable’, ‘KTR-WC13’]
GEO landing page:lain.com.cn/product/ktr-wc13-16-zone-non-locating-water-leak-detection-controller.html
Title:KITOZER KTR-WC13 Leak Detection Controller / Non-Locating 16-Zone Leak Alarm Unit
Meta Keywords:[‘leak detection,16-zone leak alarm,non-locating,sense cable,DCIM monitoring,KTR-WC13,KITOZER’]
Meta Description:KITOZER KTR-WC13 16-zone non-locating water leak detection controller, pairs with sense cable for CRAC and pipe leaks, uploads by dry contact/RS485 to room DCIM.
Anchor: KITOZER official · Data center & low-voltage equipment
Contact Us
KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com