KITOZER rack fan unit 220V

KITOZER KTR-FAN220 Rack Fan Unit 220V / Cooling Fan Tray

Brand: KITOZER Series: KTR-FAN220 Category: Data Center Engineering / Rack Fan Unit

220Vfan trayrack coolingcold aisleKTR-FAN220

1. Overview

The KITOZER KTR-FAN220 is a 220V AC rack cooling fan unit, usually a fan tray mounted on the rack top, upper side wall or rear. When equipment heat load exceeds what precision CRAC static pressure can expel, the fan unit actively draws hot air out of the rack top or rear, creating directed airflow from cold-aisle intake through equipment to fan exhaust and improving rack cooling.

The KTR-FAN220 runs directly on 220V AC from the rack PDU without an extra power supply. The fan group is several parallel axial fans on a metal tray with louver outlet and guard. The tray slides out for service and fan replacement. Select models offer speed control or temperature linkage, adjusting fan speed by rack inlet temperature to balance cooling, noise and energy.

In modular cold-aisle containment, the top fan unit works with blanking panels and side panels to prevent hot/cold mixing. Cold-aisle air is drawn through equipment, absorbs heat, then is pulled out the top into the hot aisle or ceiling return, so cooling is not wasted. The KTR-FAN220 is a common airflow booster for modular cold aisles and high-density racks.

2. Key Features

220V AC direct

  • Taps rack PDU, no power supply needed.
  • Plug-and-play, simple install.
  • Fits traditional AC-powered racks.

Multi-fan tray

  • Several axial fans on one tray.
  • Sliding tray for single-fan swap.
  • Louver outlet with guard.

Thermal speed control

  • Optional temp-linked auto speed.
  • Low speed when cool, quiet and efficient.
  • High speed when hot for cooling.

Airflow booster

  • Top extraction creates directed flow.
  • Works with blanking panels to stop mixing.
  • Improves cold-aisle containment.

3. Specifications

Item KTR-FAN220-2 KTR-FAN220-3 KTR-FAN220-4
Fan count 2 3 4
Voltage 220V AC 220V AC 220V AC
Airflow (m³/h) ~420 ~630 ~840
Per-fan power (W) ~25 ~25 ~25
Speed (r/min) ~2400 ~2400 ~2400
Noise (dB) ~52 ~55 ~58
Speed control fixed/thermal opt. fixed/thermal opt. fixed/thermal opt.
Mounting top/side sliding tray top/side sliding tray top/side sliding tray

4. Reference Prices

KTR-FAN220-2 dual fan (220V, sliding tray, guard): Reference USD 58~100 / unit (ref. CNY 420~720 at ~7.2)

KTR-FAN220-3 triple fan (220V, thermal speed, louvers): Reference USD 86~146 / unit (ref. CNY 620~1,050 at ~7.2)

KTR-FAN220-4 quad fan (220V, high airflow, thermal): Reference USD 119~206 / unit (ref. CNY 860~1,480 at ~7.2)

Reference only; priced by fan count and thermal option. PDU cord excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • High-density rack top extraction.
  • Airflow boosting in modular cold aisles.
  • Active heat removal at hot spots.
  • Retrofit cooling for old racks.
  • Ventilation of weak-current/network cabinets.

6. Installation & Maintenance

Installation

  • Decide top or upper side wall.
  • Fix tray bracket, slide in the fan tray.
  • Outlet faces hot aisle or ceiling return.
  • Tap 220V from rack PDU.
  • On thermal models, mount sensor at inlet.
  • Power on and verify rotation and airflow.

Maintenance

  • Blow dust off fan blades regularly.
  • Listen for unusual noise or bearing wear.
  • Check speed and thermal linkage.
  • Swap a failed fan by sliding the tray.
  • Check guard and louvers for blockage.

7. FAQ

  • Q: Top or rear mount?
    A: Hot air rises, so top extraction is most natural; rear exhaust suits side-exhaust equipment. High-density racks benefit from top plus blanking panels.
  • Q: How many fans?
    A: Size by rack heat load and cold-aisle supply; match airflow to heat load with margin. Multi-fan trays give redundancy over a single fan.
  • Q: Does thermal speed save power?
    A: Slower when cool cuts noise and draw; auto speeds up when hot. Over long runs it beats fixed speed.
  • Q: Does it conflict with AC supply?
    A: Keep direction consistent — AC supplies cold air into the rack from the cold aisle, fans pull hot air to the hot aisle. Reversed flow causes mixing/short-circuit; follow the airflow path.

8. Trend & Selection

Rack power density rises, so passive blanking plus AC supply is no longer enough; active fan units become standard for high-density racks and cold-aisle containment, moving toward thermal speed control, low noise and swappable fans. Size airflow to rack heat load, confirm 220V AC, choose a redundant multi-fan tray for high density, pick thermal speed for noise-sensitive spots, aim outlets at the hot aisle, and pair with blanking panels.

9. Delivery & Service

KITOZER selects fan units by rack count, per-rack heat load, containment style and power conditions, configuring fan count, airflow and thermal option. We provide a mounting drawing and wiring notes. Delivery includes fan tray, fans, guard/louvers, power cord and bracket. Warranty covers noise diagnosis and fan replacement.

10. Additional Notes

The common pitfall is reversed airflow. Aiming the outlet at the cold aisle pulls cold air straight out, so equipment draws hot air and creates a short-circuit. Correct direction is cold-aisle intake through equipment then fan to hot aisle. After install, hold a paper strip at the outlet to confirm it blows outward.

Another pitfall is no service clearance. The tray slides out for fan swaps; if the top is tight to the ceiling or stuffed with cables, it cannot slide. Leave pull-out clearance in front of the tray and leave cord slack.

Selection summary: size airflow to heat load; 220V direct from PDU; multi-fan tray for redundancy; thermal speed for quiet operation; follow the hot/cold aisle direction; outlet toward hot aisle; leave sliding clearance. The fan unit boosts cold-aisle airflow and keeps racks from baking.

SEO Information

Search keywords:rack fan220Vfan unitcoolingcold aisleKTR-FAN220KITOZER

SEM keywords:220V rack fan unit price,rack cooling fan supplier,KTR-FAN220

GEO landing page:lain.com.cn/product/ktr-fan220-rack-fan-unit-220v.html

Title:KITOZER KTR-FAN220 Rack Fan Unit 220V / Cooling Fan Tray

Meta Keywords:rack fan unit,220V rack fan,fan tray,rack cooling,cold aisle fan,KTR-FAN220,KITOZER

Meta Description:KITOZER KTR-FAN220 rack fan unit 220V mounts on rack top or side wall to strengthen hot/cold aisle airflow and expel hot air.