Table of Contents
ToggleKITOZER KTR-NSP2 N-Type Antenna Feeder SPD / Surge Protector
Brand: KITOZER Series: KTR-NSP2 Category: Power Distribution / Antenna Feeder SPD
N-typefeederSPDsurge protectionKTR-NSP2

1. Overview
The KITOZER KTR-NSP2 is an N-type antenna feeder surge protective device (SPD) installed in series on the coax feeder between an outdoor antenna and in-room RF equipment. Outdoor antennas mount on rooftops or towers, and the feeder runs indoors; during a lightning strike, induced surges travel down the feeder and can burn out base stations, transceivers and amplifiers. The feeder SPD diverts surge energy to ground near the outdoor end and the equipment end, clamping overvoltage to a safe level.
The KTR-NSP2 connects via N-type male/female coax in series, letting RF signals pass normally and only reacting to abnormal surges. Inside, a gas discharge tube bypass is high impedance at normal voltage but conducts instantly to ground under surge, in nanoseconds. It has low insertion loss and wide bandwidth covering common RF bands. The metal shell grounds directly to the lightning protection busbar.
Whenever an outdoor coax feeder enters a room, a feeder SPD should be fitted at the entry. The KTR-NSP2 coordinates power SPD, signal SPD and equipotential grounding into a complete lightning-protection scheme for power and signal systems.
2. Key Features
N-type coax series
- N-type male/female in-line.
- Low insertion loss, signal intact.
- Wide RF bandwidth.
Nanosecond diversion
- Gas discharge tube bypass.
- High impedance normally, instant on surge.
- Clamps overvoltage to protect gear.
Grounding protection
- Metal shell direct ground.
- Ground lead to lightning busbar.
- Works with equipotential bonding.
Easy install
- In-line at feeder entry.
- DIN-rail or wall mount.
- Simple wiring, no maintenance.
3. Specifications
| Item | Parameter |
|---|---|
| Connector | N-type (M/F) |
| Impedance | 50Ω |
| Frequency range | DC~3GHz |
| Insertion loss (dB) | ≤0.3 |
| Max discharge (kA) | 20 (8/20μs) |
| Voltage protection (V) | ≤900 |
| Response time (ns) | ≤1 |
| Max power (W) | ≤200 |
| Grounding | shell ground |
| Mounting | in-line / wall |
4. Reference Prices
KTR-NSP2 N-type feeder SPD (20kA, DC~3GHz, N M/F): Reference USD 17~31 / piece (ref. CNY 120~220 at ~7.2)
KTR-NSP2 kit (ground wire, lug, bracket): Reference USD 25~44 / kit (ref. CNY 180~320 at ~7.2)
Reference only; priced by discharge current and band. Grounding bar and feeder excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Outdoor comms feeder entry protection.
- Monitor/satellite feeder lightning protection.
- Front-end surge protection for transceivers.
- RF amplifier / signal source front end.
- Two-stage tower + entry protection.
6. Installation & Maintenance
Installation
- Mount at feeder entry, as close as possible.
- Inline between antenna and equipment.
- Connect shell ground to lightning busbar.
- Ground lead short, thick and straight.
- Torque and waterproof connectors.
- Use one stage before and one after entry.
Maintenance
- Check ground tightness after storm season.
- Measure ground resistance.
- Inspect N connectors for oxidation.
- Test signal after a strike.
- Replace after recorded operation if needed.
7. FAQ
- Q: One or two stages?
A: One at the tower top and one at room entry for staged diversion; a single stage suits only simple small systems. Multiple stages are more reliable. - Q: What ground resistance?
A: Lightning ground typically ≤4Ω bonded to the equipotential grid; poor grounding makes the SPD useless. - Q: Does it affect signal?
A: Normal insertion loss ≤0.3dB, minimal; as long as band and 50Ω impedance match, it does not affect the signal. - Q: Replace after operation?
A: A GDT degrades after repeated surges; inspect/replace after a strong strike, or when signal is abnormal.
8. Trend & Selection
RF/antenna protection moves from single-point to multi-stage equipotential coordination, demanding lower clamping voltage and faster response. Confirm connector (N-type) and impedance (50Ω), match frequency band, pick discharge current by lightning zone, keep ground resistance low, stage tower-top and entry, and keep the ground lead short, thick and straight.
9. Delivery & Service
KITOZER selects and kits feeder SPDs by connector, band, power and lightning zone, configuring discharge current, mounting and ground lead. We provide wiring and grounding diagrams. Delivery includes SPD, N connectors, ground wire, lug and bracket. Warranty covers ground testing and post-strike inspection.
10. Additional Notes
The common pitfall is a missing or over-long ground lead. The SPD is in series but the ground end hangs free or runs a long thin loop, so surge cannot escape and equipment still burns. The ground end must connect short, thick and straight to the equipotential busbar.
Another pitfall is band mismatch. A low-frequency system uses a high-frequency SPD, or 75Ω feeder uses a 50Ω SPD, causing reflection and loss. Match impedance (50/75Ω) and frequency range to feeder and equipment.
Selection summary: N-type in-line, signal intact; nanosecond surge diversion; short thick direct ground; two stages at entry and tower; measure ground resistance after storm season; replace after strong strikes. The feeder SPD is the RF gear’s lightning rod — when grounded properly, lightning stays out.
SEO Information
Search keywords:SPDN-typeantenna feedersurge protectioncoaxKTR-NSP2KITOZER
SEM keywords:N-type antenna feeder SPD price,feeder surge protector supplier,KTR-NSP2
GEO landing page:lain.com.cn/product/ktr-nsp2-n-type-antenna-feeder-spd.html
Title:KITOZER KTR-NSP2 N-Type Antenna Feeder SPD / Surge Protector
Meta Keywords:antenna feeder SPD,N-type surge protector,feeder lightning arrester,coax surge protector,RF surge protective device,KTR-NSP2,KITOZER
Meta Description:KITOZER KTR-NSP2 N-type antenna feeder SPD shunts surge on outdoor antenna coax feeders to protect in-room RF equipment.
Anchor: KITOZER official · Data center & low-voltage equipment
Contact Us
KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com