1. Overview

The KITOZER KTR-WS3 is an electrode water leak sensor that detects pooled water or leakage at the probe location. Two metal electrodes sit at the probe base: when dry, resistance between them is very high and the sensor reports no water; when water covers the electrodes, conductivity drops resistance sharply and the sensor detects water, sending a relay (switch) alarm to the environmental monitoring host or module.

Electrode sensors are simple and direct, suited to fixed-point water detection such as below CRAH units, near pipe joints, under raised floors, or in power-room cable trenches. The KTR-WS3 probe has two electrode pins on a base fixed to the floor or near pipes, with a cable to the monitoring module. Unlike a locating leak rope (which pinpoints the leak), an electrode sensor only judges whether water exists at the probe point — a point detector.

In data center environmental monitoring, water sensors are essential: if a unit condenses, a pipe bursts or water pools under the floor, a timely alarm notifies operations to avoid flooding equipment and short circuits. The KTR-WS3 joins temperature/humidity and smoke sensors on the monitoring platform for real-time leak alarms and interlocking.

2. Key Features

Electrode detection

  • Dual-electrode water sensing, simple principle.
  • High resistance dry, conductive on water.
  • Fast response, direct yes/no water.

Relay output

  • Dry-contact relay switch.
  • Connects to env monitoring modules/host.
  • NO/NC configurable.

Fixed-point detection

  • Suits below AC, near pipes.
  • Under-floor, cable-trench points.
  • Point water alarm.

Compact durable

  • Small probe, flexible install.
  • Corrosion-resistant electrodes.
  • Low power, long standby.

3. Specifications

Item Parameter
Detection electrode (dual pin)
Output relay switch (dry contact)
Contact rating 30V DC / 1A
Contact form NO/NC selectable
Power supply 12~24V DC
Current ≤20mA
Response time ≤1 s
Electrode material stainless/nickel-plated
Operating temp (℃) 0~60
Cable length 1.5 m standard (extendable)

4. Reference Prices

KTR-WS3 electrode water sensor (probe, 1.5m cable, relay): Reference USD 6~12 / piece (ref. CNY 45~85 at ~7.2)

KTR-WS3 multi-point kit (5 probes + acquisition module): Reference USD 44~78 / kit (ref. CNY 320~560 at ~7.2)

Reference only; priced per piece/kit. Monitoring host excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Condense/leak detection below CRAH.
  • Under-floor water alarms.
  • Near pipe joints and valves.
  • Power-room cable-trench pooling.
  • Water points in env monitoring.

6. Installation & Maintenance

Installation

  • Pick low points likely to leak.
  • Fix probe base to floor/wall.
  • Face electrodes toward possible pooling.
  • Wire to module switch input.
  • Set NO/NC and alarm threshold.
  • Test with a drop of water.

Maintenance

  • Wipe electrodes to remove scale/dirt.
  • Check cable joints for looseness.
  • Quarterly drop test.
  • Replace badly corroded probes.
  • Confirm alarm reaches the duty platform.

7. FAQ

  • Q: Electrode vs leak rope?
    A: Electrode is cheap and simple for fixed yes/no water; a locating rope pinpoints leaks along piping. Several key points with electrodes are enough.
  • Q: Does scale affect sensing?
    A: Scale lowers conductivity and may falsely read dry; clean electrodes regularly, replace when scaled badly.
  • Q: Detect oil or other liquids?
    A: Electrodes rely on conductivity; oil does not conduct and will not trigger. It is for water only, not oil.
  • Q: False alarms?
    A: Check if electrodes are bridged by moisture or the cable is wet; in dry spaces false alarms usually come from dirty electrodes or cable leakage. Clean electrodes and waterproof the wire.

8. Trend & Selection

Environmental monitoring moves from single alarms to networked multi-point and leak location; electrode probes remain the reliable point detector, complemented by locating ropes. Place probes at leak-risk points, confirm relay output matches the module, set NO/NC, add extra probes at critical points, clean electrodes regularly, and verify with drop tests.

9. Delivery & Service

KITOZER selects electrode sensors and multi-point kits by CRAH, pipe and trench layout, configuring probe count and acquisition module. We provide a point layout and wiring notes. Delivery includes probe, cable, mounting base and terminals. Warranty covers commissioning and drop-test guidance.

10. Additional Notes

The common pitfall is wrong placement. Mounted high and dry, a real leak never reaches the electrodes and the sensor never alarms. Install at the lowest point where water gathers or directly below the AC unit.

Another pitfall is never cleaning electrodes. Scale and dust cover the pins, causing either a slight conduction false alarm when dry, or no detection when real water arrives. Clean electrodes quarterly and run a drop test.

Selection summary: electrode point detection is cheap and reliable; relay output to env modules; mount at pooling low points; match NO/NC to the module; clean electrodes regularly; verify with a drop test. The water probe is the room’s water sentry — right location and clean electrodes alarm on the first leak.

SEO Information

Search keywords:water leak sensorelectrodeleak detectionenvironmental monitoringrelayKTR-WS3KITOZER

SEM keywords:electrode water leak sensor price,leak detection probe supplier,KTR-WS3

GEO landing page:lain.com.cn/product/ktr-ws3-electrode-water-leak-sensor.html

Title:KITOZER KTR-WS3 Electrode Water Leak Sensor / Detection Probe

Meta Keywords:electrode water leak sensor,water leak detection probe,water leak detector,data center leak sensor,electrode leak switch,KTR-WS3,KITOZER

Meta Description:KITOZER KTR-WS3 electrode water leak sensor detects pooled water at the probe for data center and power room leak alarms, relay output.

Anchor: KITOZER official · Data center & low-voltage equipment

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart