KITOZER UPS Parallel Redundant System

One UPS Failure = Whole Load Down? 30-200kVA 1+1 Parallel Dual-Bus Redundancy

A single UPS fault or scheduled maintenance can drop an entire critical load. KITOZER 30-200kVA online double-conversion UPS uses a 1+1 parallel redundant plus dual-bus output architecture: load is shared automatically and transferred without interruption, backed by a sealed lead-acid battery bank. Reference price about $53,300.

KITOZER 30-200kVA UPS parallel system 1+1 redundant dual bus online double conversion UPS battery bank
KITOZER 1+1 parallel UPS (parallel units + bypass cabinet + battery cabinet)

1+1 Parallel Redundancy + Dual Bus: No Outage on Unit Failure

Two 120kVA online double-conversion UPS units (3-phase in/out, output PF=1, efficiency >96%) are paralleled via parallel cables and share load by capacity. If one unit fails or switches to maintenance bypass, the other takes over the full load seamlessly with no break. Dual independent output buses feed separate paths; a parallel bypass cabinet (maintenance + static bypass, 315A) enables online maintenance without powering down.

Sealed Lead-Acid Battery Backup & Centralized Monitoring

Two groups of 12V-100AH long-life maintenance-free lead-acid batteries (64 cells total, recombination efficiency ≥99%) are installed in 32-cell standard battery cabinets with DC breakers and busbars. UPS input/output distribution panels include smart power meters with RS485/Modbus, monitoring 3-phase voltage, current, power factor and breaker status. A network card uploads everything to the dynamic monitoring platform, showing load ratio and battery runtime on a mobile APP.

Core Configuration & Reference Price (doubled)

Item Spec EXW Price (USD)
120kVA UPS unit online double-conversion, 3:3, PF=1, parallel-ready, 2 pcs $21,300
Parallel bypass cabinet maintenance + static bypass, 315A/3P, 1 $3,600
Sealed lead-acid battery bank 12V-100AH, 2 groups x 32 cells = 64 cells $15,200
Battery cabinet 32-cell standard cabinet with DC breaker, 2 $2,000
UPS input distribution panel mains in + smart meter + RS485, 1 $2,500
UPS output distribution panel dual-bus feeders + smart meter + RS485, 1 $2,500
Network card + DCIM APP SNMP/Modbus, remote monitoring, 1 set $1,100
Power cable / accessories / install ZA-YJV main cable + control wires + termination $5,000
Total reference (doubled) ~$53,300

SEO keywords: UPS parallel system, 1+1 redundant UPS, dual bus UPS, online double conversion UPS, 120kVA UPS, UPS bypass cabinet, battery bank, KITOZER

SEM keywords: UPS parallel price, data center UPS redundancy, dual bus power, UPS bypass cabinet vendor

GEO keywords: KITOZER UPS parallel vendor China, data center redundant power, dual bus UPS solution

Tags: core=UPS parallel system; long-tail=120kVA 1+1 parallel price; industry=data center power; brand=KITOZER; source=KITOZER technical documentation