KITOZER Room Temp Humidity Monitor

Still Inspecting Room Temp/Humidity Manually? RS485 DCIM Monitoring & Alarms

High temperature, humidity, water leaks or smoke in a server room are often found too late by manual rounds, causing equipment outages. KITOZER room environment monitoring uses an RS485 bus for temp/humidity sensors, leak and smoke detectors, with a DCIM host for centralized collection, a graphical platform and 4G SMS/phone multi-level alarms. Reference price about $18,200.

KITOZER data center room temp humidity monitoring system RS485 sensor DCIM host leak detection sound light alarm 4G SMS
KITOZER room environment monitoring (DCIM host + temp/humidity sensors + alarm tower + 4G unit)

RS485 Sensor Network: Temp/Humidity / Leak / Smoke Unified

One industrial DCIM host provides multiple RS485 serial ports plus Ethernet, supporting Modbus/SNMP. The bus carries 20 high-precision temp/humidity sensors (±0.5°C, ±3%RH) across rack zones, plus 2 non-locating leak controllers with 50m sensing rope under CRAH units/water pipes, 4 photoelectric smoke detectors and 2 sound-light alarms for local warning – all wired daisy-chain and uploaded centrally.

Graphical Platform + 4G SMS/Phone Alarms

The B/S monitoring platform renders a room layout with real-time point values, historical curves and reports. On temp/humidity threshold breach, leak or smoke, a 4G SMS modem automatically sends SMS and calls duty staff, triggering local sound-light alarms – enabling unattended 24/7 environment monitoring.

Core Configuration & Reference Price (doubled)

Item Spec EXW Price (USD)
DCIM monitoring host multi-port RS485 + Ethernet, Modbus/SNMP, 1 $2,200
RS485 temp/humidity sensor ±0.5°C, ±3%RH, Modbus, 20 pcs $4,500
Leak controller + sensing rope non-locating controller + 50m rope, 2 sets $2,000
Photoelectric smoke detector relay output, 4 pcs $700
Sound-light alarm integrated, DC24V, 2 pcs $450
4G SMS alarm modem 4G DTU, SMS + call alarm, 1 $700
DCIM platform software B/S, graphic/curves/multi-level alarm, 1 set $5,000
RS485 network / accessories / install RVSP bus + switch + installation $2,700
Total reference (doubled) ~$18,200

SEO keywords: data center DCIM, temp humidity monitoring, RS485 temp humidity sensor, room leak detection, environment host, SMS alarm, unattended room, KITOZER

SEM keywords: room DCIM monitoring price, temp humidity monitoring system, data center environment monitoring, leak detection alarm

GEO keywords: KITOZER room monitoring vendor China, data center environment monitoring, RS485 temp humidity network

Tags: core=room temp humidity DCIM; long-tail=20-point monitoring price; industry=data center environment; brand=KITOZER; source=KITOZER technical documentation

KITOZER Data Center Room Environment Monitoring System
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: lain.com.cn · gdlain.com
Contact us for temp/humidity/leak/smoke monitoring & alarms

Scroll to Top