Table of Contents
ToggleKITOZER KTR-SD3 Photoelectric Smoke Detector / Center Smoke Alarm Sensor
Brand: KITOZER Series: KTR-SD3 Category: Environmental Monitoring / Smoke Detection
smoke detectorphotoelectricsmoke alarmcenter environmentrelay outputKTR-SD3
1. Overview
KITOZER KTR-SD3 is a photoelectric smoke detector ceiling-mounted below the center ceiling for early smoke detection. It uses optical scattering: a chamber holds an IR emitter and receiver; normally the receiver sees nothing, but when smoke enters, particles scatter IR onto the receiver, and once light reaches a threshold it alarms. Photoelectric detectors are sensitive to smoldering, early smoke – earlier than heat detectors – suiting electrical fire risks that smoke before they flame in a center.
KTR-SD3 is a round ceiling probe with an indicator (green normal, flashing red alarm) and relay (NO/NC) output to the center’s environmental monitoring platform or alarm panel. It does not directly trigger sprinklers – centers use gas suppression; instead it uploads the smoke signal to trigger sounder/beacon, notify staff and optionally start exhaust. It is usually paired with heat detectors, gas suppression and access control in the center’s environment-and-fire linkage scheme.
In center environmental monitoring, a smoke detector is standard early warning. A tens-of-m2 center places units evenly under the ceiling by protected area. KTR-SD3 is tiered by output (relay/bus) and built-in sounder, matching different monitoring panels and fire systems. Small, cheap and simple to fit, it is the first fire eye of the center – the earlier smoke is caught, the smaller the loss.
2. Key Features
Photoelectric scatter
- IR scattering detects smoke.
- Sensitive to smolder/early smoke.
- Alarms earlier than heat.
- Chamber shields against ambient light.
Relay output
- Selectable NO/NC relay.
- Links to monitoring / alarm panel.
- Normal/alarm indication.
- Triggers sounder and exhaust.
Ceiling mount
- Round ceiling unit, discreet.
- Simple base snap-fit.
- Status LED.
- Built-in sounder option.
Center fit
- Placed by protected area.
- Pairs with heat and gas suppression.
- No sprinkler in the room.
- Early warning, low loss.
3. Specifications
| 项目 | KTR-SD3(开关量) | KTR-SD3-B(总线) | KTR-SD3-S(带蜂鸣) |
|---|---|---|---|
| 探测原理 | 光电散射 | 光电散射 | 光电散射 |
| 报警输出 | 继电器常开/常闭 | 总线寻址 | 继电器+蜂鸣 |
| 工作电压 | DC12~24V | 总线供电 | DC12~24V |
| 静态电流 | ≤0.1mA | 总线 | ≤0.2mA |
| 报警电流 | ≤50mA | 总线 | ≤80mA |
| 指示灯 | 绿/红 | 绿/红 | 绿/红+蜂鸣 |
| 安装方式 | 吸顶 | 吸顶 | 吸顶 |
| 保护面积 | ≤60m2 | ≤60m2 | ≤60m2 |
4. Reference Prices
KTR-SD3 relay smoke detector (NO/NC, ceiling). Reference USD 8~15 / pc (ref. CNY 60~110 at ~7.2)
KTR-SD3-B bus detector (addressable to fire panel). Reference USD 13~22 / pc (ref. CNY 90~160 at ~7.2)
KTR-SD3-S sounder detector (audio-visual). Reference USD 11~19 / pc (ref. CNY 80~140 at ~7.2)
Reference only; by output and quantity; monitoring panel, wiring and fire linkage install excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Early smoke alarm below center ceiling.
- Power room / battery room monitoring.
- Archive and storage fire warning.
- Front-end probe for monitoring.
- Smoke detection in gas-suppressed zones.
6. Installation & Maintenance
Installation
- Mount centrally on the ceiling, away from vents.
- Place by <=60 m2 protection area, compliant spacing.
- Wire DC12~24V and relay to the monitoring panel.
- Snap the base; twist the probe in.
- Avoid AC drafts and EMI.
- Test with a smoke gun after install.
Maintenance
- Function-test quarterly with a smoke gun.
- Dust the chamber; dust blocks or false-alarms.
- Check the indicator.
- Frequent false alarms: check dust, grease, humidity.
- Replace damaged probes.
7. FAQ
- Q: Photoelectric or ionization?
A: Photoelectric suits smolder smoke, has no radioactive source, and dominates centers/offices; ionization senses fast flaming better but is radioactive. Pick photoelectric for centers. - Q: How many per center?
A: About 60 m2 each, evenly under ceiling; add points under beams and in corners. Larger centers run units in parallel to the panel. - Q: Will it spray water on alarm?
A: No. Centers use gas suppression; smoke only uploads for sounder and exhaust linkage. Water sprinklers would ruin gear – centers forbid them. - Q: Why so many false alarms?
A: Usually dust, grease, humidity or insects in the chamber. Clean it; mount away from kitchens, bathrooms and direct airflow.
8. Trend & Selection
Center environmental monitoring has moved from ‘temperature only’ to ‘smoke-heat-power-water full coverage’, with smoke detectors as standard front ends. Relay-to-monitoring remains mainstream; addressable bus models grow in large linked fire projects. Choose output (relay/bus) by system, sounder by site, and design linkage with gas suppression and the monitoring platform.
9. Delivery & Service
KITOZER supplies photoelectric smoke detectors in volume, sized by room area and placement plan. Delivery includes probe, base, mounting and manual; relay models include wiring notes and pair with the monitoring panel.
10. Additional Notes
The common issue is not ‘no alarm’ but ‘installed and never tested’. Years without a smoke-gun test mean a dust-choked probe may fail when real smoke arrives. Test quarterly – minutes buy years of peace.
Another trap is mounting right under an AC vent: airflow blows smoke away and delays detection. Avoid vents and beam-shaded corners.
Selection summary: centers choose photoelectric; relay to monitoring; place by 60 m2; avoid vents and grease; test with smoke quarterly; check dust on false alarms. The smoke detector is the earliest nose of center fire safety – a little more sensitivity saves a lot of loss.
SEO Information
Search keywords:smoke detectorphotoelectricsmoke alarmcenter environmentrelay outputKTR-SD3KTR-SD3KITOZER
SEM keywords:KTR-SD3 price, smoke detector supplier, KITOZER
GEO landing page:lain.com.cn/product/ktr-sd3-photoelectric-smoke-detector.html
Title:KITOZER KTR-SD3 Photoelectric Smoke Detector / Center Smoke Alarm Sensor
Meta Keywords:smoke detector, photoelectric, smoke alarm, center environment, relay output, KTR-SD3, KTR-SD3, KITOZER
Meta Description:KITOZER KTR-SD3 Photoelectric Smoke Detector / Center Smoke Alarm Sensor – KITOZER professional data center & low-voltage equipment.
Anchor: KITOZER official · Data center & low-voltage equipment