KITOZER
KITOZER

KITOZER TH large display

KITOZER KTR-THD2 Large Temp-Humidity Display Board

Brand: KITOZER Series: KTR-THD2 Category: Environmental Monitoring / Display Board

large TH displayLED digitalover-limit alarmwarehouse roomenv boardKTR-THD2

KITOZER KTR-THD2 large LED temperature humidity display board for warehouse room environmental monitoring

1. Overview

KITOZER KTR-THD2 is a large LED digital or dot-matrix display board that shows live temperature and humidity on a big screen, wall-mounted in warehouses, rooms, labs or corridors so people see the environment at a glance. Compared with a small indoor thermometer, the big screen reads from 5~20 m away, with large fast-updating digits, over-limit audible/visual alarm and data upload (RS485/Ethernet) — the “public signage” of an environmental monitoring system. The panel has a built-in TH sensor and can also take an external sensor, matching the DCIM platform.

In room and warehouse environmental management, a back-end DCIM platform alone is not enough: staff walking into the room or warehouse need to see at a glance whether temp and humidity are within range. KTR-THD2 hangs in a visible spot, showing red temperature and humidity digits; on exceedance the digits flash red or a buzzer alarms. The board links via RS485 or Ethernet to the DCIM host, which logs history curves while the board gives on-site signage. Suits pharma warehouses, food plants, data centers and archives.

Display panels range from 10 to over 30 inches, with 2~5 inch digit height for long-distance reading. They support calibration, upper/lower alarm limits and alarm history. Powered by 220V or 12V, wall- or flush-mounted. Optional time, date and multi-sensor switching. Paired with a TH transmitter, they form a complete “back-end monitoring + on-site board” environmental visualization.

2. Key Features

Large LED display

  • Digital/dot-matrix, long reading distance.
  • Clear red digits, fast refresh.
  • Temp and humidity on one screen.

Real-time sampling

  • Built-in TH sensor.
  • Expandable with external sensors.
  • Values sync with DCIM platform.

Over-limit alarm

  • Settable limits; flashing on exceedance.
  • Audible buzzer.
  • Alarm history query.

Networked

  • RS485/Ethernet to DCIM host.
  • Modbus, integrates with platform.
  • 220V or 12V supply.

3. Specifications

Item KTR-THD2-S (basic) KTR-THD2-P (alarm) KTR-THD2-N (network)
Display LED digital LED digital LED dot-matrix
Temp range -20~60 C -20~60 C -20~60 C
Humidity range 0~100%RH 0~100%RH 0~100%RH
Temp accuracy ±0.5 C ±0.5 C ±0.3 C
Alarm No Audible/visual A/V + network upload
Interface None RS485 RS485/Ethernet
Power 220V AC 220V AC 220V AC
Mounting Wall Wall/flush Wall/flush

4. Reference Prices

KTR-THD2-S basic TH display (digital, built-in sensor, wall): Reference USD 39~67 / unit (ref. CNY 280~480 at ~7.2)

KTR-THD2-P alarm TH board (audible/visual, RS485): Reference USD 63~108 / unit (ref. CNY 450~780 at ~7.2)

KTR-THD2-N networked TH board (dot-matrix, Ethernet, upload): Reference USD 94~167 / unit (ref. CNY 680~1,200 at ~7.2)

Reference only; priced by screen size, alarm and communication; DCIM host and wiring excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Room entrance TH signage.
  • Warehouse and pharma storage display.
  • Lab and plant TH display.
  • Archive and museum monitoring.
  • On-site display for DCIM systems.

6. Installation & Maintenance

Installation

  • Pick a visible wall spot, away from direct sun.
  • Wall-mount the panel level.
  • 220V supply, grounded.
  • RS485 or Ethernet to the DCIM host.
  • Set temp/humidity limits and alarm thresholds.
  • Calibrate display against a standard source.

Maintenance

  • Clean the screen surface regularly.
  • Check displayed values are accurate.
  • Re-calibrate after sensor drift.
  • Test alarm function.
  • Check wiring on communication loss.

7. FAQ

  • Q: Does the board measure itself or take a sensor?
    A: The basic model has a built-in sensor and measures locally; the network model can take an external sensor and the board only displays data fed in. Choose external-sensor for multi-point monitoring.
  • Q: How does alarm work?
    A: Set upper/lower limits on the board; on exceedance, digits flash and the buzzer sounds. The network model also uploads the alarm to the DCIM platform for SMS or audible/visual notification.
  • Q: How far is the reading distance?
    A: 2-inch digits read ~5~8 m; 4-inch ~10~15 m; 5-inch ~15~20 m. Choose digit height by mounting distance.
  • Q: Does the board need calibration?
    A: Yes. The built-in sensor drifts over time; calibrate every six months against a standard TH source to keep displayed values trustworthy.

8. Trend & Selection

Environmental display evolves from small thermometers to networked large boards and data signage; the board no longer just displays but also publicizes data and visualizes alarms. Data centers, pharma warehouses and archives raise the bar for environmental signage. Choose digit height by reading distance; pick the audible/visual model for alarm; pick the network RS485/Ethernet model for data upload; keep the screen away from direct sun and AC outlets; mount at 1.5~1.8 m eye level; calibrate the sensor periodically.

9. Delivery & Service

KITOZER supplies KTR-THD2 TH display boards in volume, configured by point count and networking needs. We provide installation wiring diagrams and alarm-threshold setup notes. Delivery includes display board, wall bracket, power adapter and manual. Warranty covers sensor drift, missing segments and communication faults.

10. Additional Notes

The common pitfall is bad placement. Hanging the board directly above an AC outlet, cold airflow makes the displayed temperature read far lower than actual; mounting on a west-facing wall, afternoon sun heats it and inflates the reading. The board must represent the monitored environment — away from outlets, heat sources and direct sun, at eye level.

Another pitfall is skipping calibration. After a year or two, the built-in sensor drifts 2~3 C from reality; staff look at the board and think conditions are fine, but the environment is already out of spec. Calibrate against a standard source every six months so the display is trustworthy and alarms effective.

Selection summary: large LED digital; digit height by distance; audible/visual for alarm; networked model to DCIM; away from outlets and heat; calibrate every six months. The TH board is the face of environmental monitoring — facing the site with accurate data, environmental management becomes visible and trustworthy.

SEO Information

Search keywords:TH displaylarge boardLED TH screenenv signagewarehouse roomKTR-THD2KITOZER

SEM keywords:temperature humidity display price,LED TH board supplier,warehouse environment signage,KTR-THD2

GEO landing page:lain.com.cn/product/ktr-thd2-temperature-humidity-display.html

Title:KITOZER KTR-THD2 Large LED Temperature Humidity Display Board

Meta Keywords:[‘temperature humidity display,large LED TH board,warehouse TH display,room environment board,LED TH screen,KTR-THD2,KITOZER’]

Meta Description:KITOZER KTR-THD2 large LED temperature-humidity display board shows live TH with over-limit alarm for warehouse, room and lab environmental signage.

Anchor: KITOZER official · Data center & low-voltage equipment

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart