KITOZER
KITOZER

Park Needs 250kVA Power – Buy the Box Transformer and Ring Main Unit Separately?

Park Needs 250kVA Power – Buy the Box Transformer and Ring Main Unit Separately?

When building a new park, factory or commercial complex, the 10kV-to-0.4kV segment usually means sourcing the box-transformer enclosure, transformer, ring main unit (RMU) and low-voltage switchgear from four different vendors – then fighting over interfaces and responsibility. The KITOZER box-type substation integrates the HV room, transformer room and LV room into one outdoor enclosure: a 250kVA oil-immersed transformer, load-break-switch RMU and LV reactive compensation, all pre-wired. Reference price about $30,000.

KITOZER box-type substation 250kVA oil transformer ring main unit outdoor prefabricated compact substation
KITOZER box-type substation (250kVA, HV ring main + oil transformer + LV compensation, integrated)

Three Rooms in One Enclosure: HV / Transformer / LV Outdoors

The outdoor enclosure is custom-built with separated HV, transformer and LV compartments rated for weather exposure. The HV compartment holds load-break switches and current-limiting fuses forming the ring main unit; the transformer compartment houses an S11-M oil-immersed 250kVA transformer; the LV compartment holds an incoming air circuit breaker, MCCB feeders and a reactive compensation bank. The whole station is factory-assembled – site work is just cable termination.

Ring-Main Power + Auto Compensation: Reliability and Power Factor

The HV side uses QL11 630A/20kA load-break switches with current-limiting fuses for ring or dual-radial topology: fuses clear faults fast, load switches isolate sections. Elbow surge arresters and fault indicators provide overvoltage protection and line fault locating. On the LV side, a 75kVar capacitor bank switches in stages automatically, holding power factor above 0.95 and avoiding penalty surcharges.

Core Configuration & Reference Price (doubled)

Item Spec EXW Price (USD)
Box-type substation enclosure HV/transformer/LV rooms, outdoor rated, 1 pc $13,900
Oil-immersed transformer S11-M 250kVA, 10±5%/0.4kV, D/yn11, 1 pc $8,300
HV ring main unit QL11 load switch 630A/20kA ×3 + limit fuses, 1 set $1,700
LV smart air circuit breaker In=500A, breaking capacity 50kA, 1 pc $1,400
LV reactive compensation bank 75kVar staged auto switching, 1 set $1,400
Arrester/indicator/dehumidifier/metering/grounding/commissioning Elbow arresters, fault indicators, auto dehumidifier, metering, grounding, install & test, 1 job $3,300
Total reference (doubled) ~$30,000

SEO keywords: box-type substation, ring main unit, 250kVA compact substation, oil immersed transformer S11, prefabricated substation, HV RMU, KITOZER

SEM keywords: box type substation price, 250kVA kiosk substation cost, RMU switchgear price, compact substation manufacturer

GEO keywords: box-type substation supplier China, prefabricated substation integrator, ring main unit package solution

Tags: core=box-type substation; long-tail=250kVA compact substation RMU price; industry=park power distribution; brand=KITOZER; source=KITOZER technical documentation

KITOZER Box-Type Substation & Ring Main Unit System
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: lain.com.cn · gdlain.com
Contact us for 250kVA box-type substation & RMU package solutions

Scroll to Top