1. Overview

KITOZER KTR-OS48 is a high-efficiency oil separator with automatic drain, used in data center chiller plants and refrigeration loops. Compressor discharge carries atomized lubricant; without separation, oil films the inner walls of condenser and evaporator tubes, lowering heat transfer, and returns to the expansion valve, upsetting oil balance. KTR-OS48 uses three stages—expansion for lower velocity, baffle impingement, and a wire-mesh cartridge—to capture droplets into a bottom sump.

Automatic drain means a float-type automatic return valve on the sump: when oil rises, the float lifts and high-pressure oil flows back to the crankcase by pressure difference; when level drops, the float closes and blocks high-pressure vapor from entering the return line. No manual operation, no solenoid power—oil return keeps working even on power loss, which matters for always-on data center chillers.

Compared with simple filter separators, KTR-OS48 combines baffle gravity separation with cartridge fine separation: low initial pressure drop and high efficiency, compatible with R22, R134a, R410A and R32. Top outlet has a pressure tap; side sight glass shows oil level; bottom has a drain valve. It sits between discharge line and condenser, in series with receiver and drier-filter.

2. Key Features

Three-stage separation

  • Expansion lowers velocity for gravity settling.
  • Baffles impinge large droplets.
  • Stainless mesh cartridge captures micron mist.

Float automatic return

  • Mechanical float valve opens/closes without power.
  • High level returns oil; low level closes.
  • Keeps working on power loss.

Monitoring & maintenance

  • Sight glass shows return flow.
  • Top pressure tap for discharge pressure.
  • Bottom drain for sludge.
  • Replaceable cartridge, cleanable vessel.

Pressure & materials

  • Seamless steel vessel rated 3.0 MPa.
  • Stainless mesh, refrigerant-resistant seals.
  • Flange or thread ports for easy install.

3. Specifications

Item KTR-OS48-05 KTR-OS48-10 KTR-OS48-20
Gas flow (m³/h) ~500 ~1000 ~2000
Port size DN25 thread DN40 flange DN65 flange
Separation baffle+mesh baffle+mesh baffle+cartridge
Working pressure (MPa) 3.0 3.0 3.0
Working temp (℃) -20~120 -20~120 -20~120
Oil return float auto float auto float+solenoid
Sight glass yes yes yes
Mounting vertical vertical vertical

4. Reference Prices

KTR-OS48-05 small (DN25, float return, sight glass): Reference USD 250~444 / unit (ref. CNY 1,800~3,200 at ~7.2)

KTR-OS48-10 medium (DN40 flange, mesh cartridge, gauge): Reference USD 500~944 / unit (ref. CNY 3,600~6,800 at ~7.2)

KTR-OS48-20 large (DN65 flange, solenoid return, spare cartridge): Reference USD 1,083~1,875 / unit (ref. CNY 7,800~13,500 at ~7.2)

Reference only; by gas flow, port size, return type and refrigerant. Piping and installation excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Discharge-side separation for water chillers.
  • Oil-loop protection for screw/piston compressors.
  • VRF and modular outdoor units.
  • Heat pumps and precision AC loops.
  • Retrofits where old separator lowers efficiency.

6. Installation & Maintenance

Installation

  • Place between discharge line and condenser.
  • Mount vertical; follow flow arrow.
  • Weld with vessel cooling to protect seals.
  • Connect return line to crankcase.
  • Orient sight glass for viewing.
  • Fit pressure tap to control system.
  • Pressure-test, evacuate, charge and run.

Maintenance

  • Watch sight glass for continuous return.
  • Check float valve if return stops.
  • Track cartridge dp annually; change when high.
  • Drain oil and sludge regularly.
  • Inspect welds and flanges for oil leaks.

7. FAQ

  • Q: Float auto vs solenoid return?
    A: Float works mechanically without power; solenoid needs supply and control logic. Choose float for unmanned rooms; combine both for critical plants.
  • Q: How to size?
    A: By rated compressor discharge volume (referenced to suction state) with 1.2x headroom; match discharge pipe diameter; confirm seal compatibility with refrigerant.
  • Q: Cartridge life?
    A: By pressure differential; check when discharge pressure rises or sight glass return fades. Generally replace every 2 years with compressor service.
  • Q: Insulate the return line?
    A: Yes. High-pressure oil and small vapor fraction would frost and condense; insulate to prevent flash-gas disrupting return.

8. Trend & Selection

Data center chillers move toward high efficiency and always-on operation, pushing separators from simple filters to float-auto-return plus cartridge structures that cut manual intervention. Size by discharge volume with 1.2x headroom, match pipe diameter, choose float return for unmanned rooms, confirm refrigerant seal compatibility, insulate the return line, and change cartridges by dp.

9. Delivery & Service

KITOZER sizes separators by compressor model, discharge volume, port size, refrigerant and layout, configuring vessel size, return method and cartridge. We provide a piping drawing and pressure rating sheet. Delivery includes vessel, float valve, sight glass, pressure tap, spare cartridge and flange bolts. Warranty covers installation guidance and leak re-check.

10. Additional Notes

The common pitfall is sizing by pipe diameter rather than discharge volume. Pipe is DN40 so a DN40 separator is picked, but full-load discharge exceeds capacity and velocity stays too high, carrying droplets over. Look up compressor discharge volume, reference to suction state, and add 20% headroom.

Another pitfall: an undersized or overlong return line. High resistance keeps oil in the sump while the sight glass shows a high level. Keep the return line at least DN10, short, and avoid upward risers that form liquid columns.

Selection summary: size by discharge volume with headroom; mount vertically along the flow arrow; float return suits unmanned rooms; insulate and keep the return line short and fat; change cartridges by dp; pressure-test and watch the sight glass. The separator guards the oil loop, and auto return keeps the chiller running.

SEO Information

Search keywords:oil separatorautomatic drainfloat returnchiller plantKTR-OS48KITOZER

SEM keywords:high efficiency oil separator price,automatic drain oil separator supplier,chiller oil separator sizing,KTR-OS48

GEO landing page:lain.com.cn/product/ktr-os48-high-efficiency-oil-separator-automatic-drain.html

Title:KITOZER KTR-OS48 High-Efficiency Oil Separator with Automatic Drain / Refrigeration Loop Protection

Meta Keywords:high efficiency oil separator,automatic drain oil separator,chiller oil separator,float return,KTR-OS48,KITOZER

Meta Description:KITOZER KTR-OS48 high-efficiency oil separator with automatic float drain captures discharge oil in data center chillers and refrigeration loops.

Anchor: KITOZER official · Data center & low-voltage equipment

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart