ToggleKITOZER KTR-BAT120V 12V120Ah Deep-Cycle VRLA Battery / UPS Backup Power
Brand: KITOZER Series: KTR-BAT120V Category: Power Distribution / VRLA Battery
12V120AhVRLAdeep cycleUPS backupKTR-BAT120V

1. Overview
KITOZER KTR-BAT120V is a 12V120Ah deep-cycle VRLA (valve-regulated lead-acid) battery used as the DC energy storage unit in UPS, energy storage and data center backup systems. On mains failure, the battery bank supplies DC through the UPS inverter to keep servers, network gear and cooling running, buying time for generator startup or orderly shutdown. 12V120Ah is a common size in data center UPS banks, stacked to a 192V or 240V DC bus and matched to the UPS rating.
VRLA uses AGM (absorbent glass mat) separators; electrolyte is held in the mat and doesn’t flow, so the battery is sealed and maintenance-free with no watering in normal use. A relief valve opens on abnormal internal pressure and stays closed in service; hydrogen and oxygen recombine into water with low water loss. Deep-cycle means the battery can discharge deeply without significant life loss, suiting frequent or deep-discharge energy storage—unlike shallow-cycle starter batteries (car batteries), deep-cycle plates are thicker and tougher.
The case is flame-retardant ABS with tin-plated copper terminals for good conduction and corrosion resistance. Built-in handles aid transport, and a bottom flange fixes it in a rack or cabinet. Ships charged, ready to install. It matches UPS charging modules: float charge ~2.25~2.30V/cell (25℃), equalize ~2.35~2.40V/cell. Bank capacity and cell count are sized by UPS backup time—longer backup needs more capacity or parallel strings.
2. Key Features
Deep-cycle long life
- AGM mat, immobilized electrolyte.
- Deep-cycle design tolerates deep discharge.
- Design float life 5~8 years (25℃).
Sealed maintenance-free
- Valve-regulated seal, no watering.
- Relief valve vents; low water loss.
- Mounts in any orientation (except inverted).
Structure & safety
- Flame-retardant ABS, tinned copper terminals.
- Handles and bottom flange for fixing.
- Charged from factory.
Charging & compatibility
- Float 13.5~13.8V (25℃).
- Equalize 14.1~14.4V (25℃).
- Compatible with mainstream UPS chargers.
3. Specifications
| Item | KTR-BAT120V | KTR-BAT120V-2 | KTR-BAT120V-G |
|---|---|---|---|
| Rated voltage | 12V | 12V | 12V |
| Rated capacity (20hr) | 120Ah | 120Ah | 120Ah |
| End voltage | 10.5V | 10.5V | 10.5V |
| Float (25℃) | 13.5~13.8V | 13.5~13.8V | 13.5~13.8V |
| Equalize (25℃) | 14.1~14.4V | 14.1~14.4V | 14.1~14.4V |
| Design life (25℃) | 5~8 yr | 8~10 yr | 10~12 yr |
| Terminal | M8 copper | M8 copper | M8 copper |
| Weight | ~34kg | ~36kg | ~38kg |
4. Reference Prices
KTR-BAT120V standard deep-cycle VRLA (12V120Ah, 5~8 yr): Reference USD 94~160 / unit (ref. CNY 680~1,150 at ~7.2)
KTR-BAT120V-2 long-life VRLA (12V120Ah, 8~10 yr): Reference USD 128~219 / unit (ref. CNY 920~1,580 at ~7.2)
KTR-BAT120V-G premium deep-cycle (12V120Ah, 10~12 yr): Reference USD 178~303 / unit (ref. CNY 1,280~2,180 at ~7.2)
Reference only; by life grade and quantity. Rack, inter-cell links and freight excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Data center UPS DC battery banks.
- Industrial UPS and energy storage backup.
- Telecom sites and room backup power.
- Solar PV deep-cycle storage.
- Bridge power before generator start.
6. Installation & Maintenance
Installation
- Keep the battery room at 20~25℃.
- Fix rack/cabinet; lay cells by layer.
- Series-connect, watch polarity.
- Torque links to spec.
- Measure string voltage; confirm no reverse.
- Connect UPS DC bus; equalize then float.
- Record each cell’s open-circuit voltage.
Maintenance
- Quarterly read each cell voltage and internal resistance.
- Check links for looseness or heat.
- Keep the room ventilated and temperature-controlled.
- Equalize or replace lagging cells.
- Run a verification discharge once a year.
7. FAQ
- Q: How many cells?
A: By the UPS DC bus: a 192V system uses 16 x 12V in series, 240V uses 20; parallel strings sized by backup time. - Q: Why temperature-control the room?
- Q: What about swelling?
A: Swelling means gas generation, water loss or overcharge—replace immediately to avoid leakage or rupture, and check the UPS charge voltage.- Q: Disposal of old cells?
A: Lead-acid is hazardous waste; never dump it. Use a licensed recycler to avoid acid and heavy-metal pollution. - Q: What about swelling?
8. Trend & Selection
Backup power is moving from pure VRLA to VRLA plus lithium, but VRLA remains mainstream for maturity, safety and cost. Choose series count by DC bus voltage, capacity and parallel strings by backup time, life grade by room temperature and life requirement, pick long-life for critical systems, monitor internal resistance and voltage regularly, and keep the room at 20~25℃ with ventilation.
9. Delivery & Service
KITOZER selects batteries by UPS bus voltage, backup time, load power and room conditions, configuring series count, parallel strings and life grade. We provide a capacity calculation sheet and layout. Delivery includes cells, inter-cell links, terminal bolts and manual. Warranty covers installation guidance and verification-discharge support.
10. Additional Notes
The common pitfall is sizing by UPS nameplate kVA without checking backup time: a 10kVA UPS with one 12V120Ah string only lasts ~15 min at full load when 30 min was required. Compute required Ah as load W x hours / (inverter efficiency x depth of discharge), then choose parallel strings.
Another pitfall is mixing old and new cells: a high-resistance old cell becomes the weak link in series, overcharging first and over-discharging last. Keep the same batch, model and life grade; when replacing a lagging cell, match the batch.
Selection summary: series count by bus voltage; capacity/parallel by backup time; control 20~25℃; same batch per string; monitor resistance and voltage; swap on swelling; recycle old cells. The battery is the heart of the UPS—size and grade it right and it holds the line on mains failure.
SEO Information
Search keywords:12V120AhVRLAdeep cycleUPS batterybackup powerKTR-BAT120VKITOZER
SEM keywords:12V120Ah battery price,VRLA deep cycle supplier,UPS backup battery,KTR-BAT120V
GEO landing page:lain.com.cn/product/ktr-bat120v-12v120ah-deep-cycle-vrla-battery.html
Title:KITOZER KTR-BAT120V 12V120Ah Deep-Cycle VRLA Battery / UPS Backup Power
Meta Keywords:12V120Ah battery,VRLA battery,deep cycle battery,UPS battery,sealed lead acid battery,backup power battery,KTR-BAT120V,KITOZER
Meta Description:KITOZER KTR-BAT120V 12V120Ah deep-cycle VRLA sealed lead-acid battery for UPS, energy storage and data center backup systems.
Anchor: KITOZER official · Data center & low-voltage equipment
Contact Us
KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com