KITOZER
KITOZER

Fans at Full Blast and Still Overheating? Rack Liquid Cooling and CDU Are the Answer

Fans at Full Blast and Still Overheating? Rack Liquid Cooling and CDU Are the Answer

As per-rack power density keeps climbing, air cooling hits alarm temperatures, fans scream at full speed and hot spots still persist. The KITOZER liquid-cooling rack and CDU (coolant distribution unit) pairs a 45U SGCC liquid-cooling rack with a 65kW rack-mount CDU, leak-free UQD quick-disconnect couplings, and full leak/water/temp/humidity monitoring to pull heat out with liquid. Reference price about $31,500.

KITOZER liquid cooling rack CDU coolant distribution unit 65kW UQD quick disconnect leak detection 45U
KITOZER liquid-cooling rack + 65kW CDU (UQD quick couplings + leak monitoring)

45U Liquid-Cooling Rack: SGCC Cabinet + PDU + Monitoring

The liquid-cooling rack is built from SGCC galvanized steel at 2000×600/800×1200 mm, 45U capacity, 1400 kg static / 800 kg dynamic load, with built-in PDU and rack monitoring. The door uses a smart lock supporting card, face, remote and mechanical unlock; a 10-inch touchscreen locally shows CDU status, water leak and door state.

65kW CDU + UQD Quick Disconnect + Leak Detection

The 19-inch 4U rack-mount CDU delivers 65kW cooling at 20-150 LPM, compatible with deionized water / glycol / propylene glycol, about 70 kg, with RJ45 uplink to the monitoring platform. The UQD-D04ZRS2B02 double-blocking quick coupling handles 1.6 MPa and 1000 mate/de-mate cycles without drips. The leak sensor triggers at >=0.5 mL within 0.5 s, backed by drain-pan water sensors, in-rack temp/humidity sensors and door interlock switches – alarms in seconds.

Core Configuration & Reference Price (doubled)

Item Spec EXW Price (USD)
Liquid-cooling rack KZ-LC2000-600 2000x600x1200mm, 45U, SGCC, PDU+monitoring, 1 pc $7,800
Liquid-cooling rack KZ-LC2000-800 2000x800x1200mm, 45U, SGCC, PDU+monitoring, 1 pc $8,400
Liquid-cooling CDU KZ-CDU-65kW 65kW, 20-150LPM, 19-inch 4U, RJ45, 1 pc $12,600
UQD double-blocking quick coupling 1.6 MPa, -55~+125C, 1000 cycles, 4 pcs $400
Leak/water/temp-humidity/door switch set Leak sensor + drain-pan water + temp/humidity + door interlock, 2 sets $1,100
Smart door lock + 10″ touchscreen Card/face/remote/mechanical unlock, 10″ touch HMI, 1 set $1,200
Total reference (doubled) ~$31,500

SEO keywords: liquid cooling rack, CDU coolant distribution unit, 65kW CDU, UQD quick disconnect, leak detection, 45U liquid-cooling rack, data center liquid cooling, KITOZER

SEM keywords: liquid cooling rack price, CDU coolant distribution unit cost, rack-mount CDU, UQD quick coupling

GEO keywords: liquid cooling rack manufacturer China, data center liquid cooling solution, CDU supplier

Tags: core=liquid cooling rack & CDU; long-tail=65kW CDU coolant distribution unit price; industry=data center / high-density compute; brand=KITOZER; source=KITOZER technical documentation

KITOZER Liquid Cooling Rack & CDU
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: lain.com.cn · gdlain.com
Contact us for 45U liquid-cooling racks, 65kW CDUs, UQD couplings & leak monitoring