KITOZER SC duplex UPC OM4

KITOZER KTR-SCUPC5 SC Duplex UPC OM4 Fiber Adapter (Coupler)

Brand: KITOZER Series: KTR-SCUPC5 Category: Data Center Engineering / Fiber Adapter

SC duplexUPCOM4ceramic sleeveKTR-SCUPC5

KITOZER KTR-SCUPC5 SC duplex UPC OM4 fiber optic adapter coupler blue

1. Overview

The KITOZER KTR-SCUPC5 is an SC duplex UPC OM4 fiber adapter, also called a fiber coupler or flange, used to mate SC plugs on patch panels, fiber termination boxes and patch cords. A blue housing identifies the UPC (physical contact) polish, and a precision ceramic sleeve aligns the two ferrules for low-loss optical continuity.

OM4 is a 300/550 m multimode fiber standard suited to 10 GbE and even 40G/100G SR4 short-reach links. The UPC end face is spherically polished with tight control of curvature radius and ferrule eccentricity, giving low insertion loss and high return loss — ideal for high-speed Ethernet, storage area networks and data center backbones. The duplex body integrates transmit (Tx) and receive (Rx) channels side by side, so one plug completes the bidirectional link.

The adapter housing is PC engineering plastic, UL94 V-0 flame-retardant, with standard SC push-pull latches that lock after mating to prevent loosening. It is panel-mountable (with flange) or stackable, fitting generic SC patch panels. Each adapter is insertion-loss sampled at the factory with test data attached.

2. Key Features

UPC low loss

  • Blue housing marks UPC.
  • Spherical polish, controlled curvature.
  • Low insertion, high return loss.
  • Suits high-speed short-reach links.

OM4 multimode

  • Mates OM4 fiber.
  • Backward compatible with OM3/OM1.
  • 10G and above short reach.
  • Bandwidth for 40G/100G SR4.

Ceramic alignment

  • Zirconia ceramic sleeve.
  • High ferrule concentricity.
  • Consistent re-mating.
  • Long wear life.

Latch and housing

  • SC push-pull latch locks.
  • UL94 V-0 flame-retardant plastic.
  • Panel-flange mountable.
  • Duplex Tx/Rx in one body.

3. Specifications

Item Parameter
Adapter type SC duplex UPC
Fiber type OM4 multimode (OM3/OM1 compatible)
Polish UPC spherical
Insertion loss ≤0.3 dB
Return loss ≥50 dB
Mating cycles ≥1000
Sleeve material zirconia ceramic
Housing PC, UL94 V-0
Operating temp -20~70℃
Mounting panel flange / stackable

4. Reference Prices

KTR-SCUPC5 SC双工UPC OM4适配器(单只): Reference USD 1~2 / pc (ref. CNY 8~18 at ~7.2)

KTR-SCUPC5 25只装(含检测报告): Reference USD 25~53 / box (ref. CNY 180~380 at ~7.2)

Reference only; priced per pc. Patch cords and patch panel itself excluded.. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Data center fiber patch panels.
  • Low-voltage room fiber boxes.
  • 10G switch optical ports.
  • SAN storage networks.
  • Building structured cabling fiber links.

6. Installation & Maintenance

Installation

  • Confirm UPC (blue); do not mix with APC (green).
  • Panel hole per SC standard.
  • Press adapter into flange until latched.
  • Insert patch cord until it clicks.
  • Clean end face with a cleaner pen before/after.
  • Keep dust caps on when unused.

Maintenance

  • Clean end face periodically with a cleaner pen.
  • Check latch tightness.
  • Replace if face is contaminated or scratched.
  • Do not mix UPC and APC adapters.
  • Sample-test link optical power.
  • Replace lost dust caps promptly.

7. FAQ

  • Q: UPC vs APC?
    A: UPC is spherical polish (blue), return loss ≥50 dB, common in multimode and single-mode data links. APC is 8-degree angled polish (green), return loss ≥60 dB, common in PON/cable TV. The end shapes differ — do not mix, or the faces will scratch and loss will rise.
  • Q: Can an OM4 adapter take OM3 fiber?
    A: Yes. The OM4 adapter is backward-compatible with OM3 and OM1 multimode. The adapter itself does not set the fiber grade; the link bandwidth is limited by the lowest-grade fiber in the chain.
  • Q: Is 0.3 dB insertion loss good?
    A: 0.3 dB is a good multimode SC adapter level; typical industrial products sit at 0.2~0.5 dB. For dense data center cabling choose ≤0.3 dB to control total link loss.
  • Q: Do adapters need periodic replacement?
    A: The ceramic sleeve lasts about 1000 mating cycles; normal room cabling needs no replacement for years. Replace only if the face is scratched, the latch is loose, or loss rises abnormally.

8. Trend & Selection

As data centers move to 40G/100G/400G, dense OM4/OM5 short-reach links raise the bar on insertion loss and re-mating consistency. Confirm the polish type (UPC blue / APC green) and fiber grade (OM4); for dense cabling prefer ceramic-sleeve, low-loss products, and manage end-face colors uniformly to avoid mixing.

9. Delivery & Service

KITOZER selects the KTR-SCUPC5 by panel port count and fiber grade, providing sampled insertion-loss data and flame-rating certificates. Each adapter ships in an individual dust bag, 25 per box, with a test report. Warranty covers end-face cleaning and link-loss test guidance.

10. Additional Notes

A common pitfall is mixing UPC and APC. Many installers look only at the SC shape and plug a blue UPC cord into a green APC adapter; the angled face then collides with the spherical face, scratching the ferrule after a few mates and spiking loss. Manage cabling by color: blue for UPC, green for APC, and label each panel port.

Another pitfall is a dirty end face. Dust inside the sleeve rubs onto the ferrule face on every mate, raising insertion loss or breaking the link. Use a cleaner pen before every plug, and keep dust caps on when unused.

Selection summary: SC duplex UPC blue; OM4 multimode compatible with OM3; ceramic sleeve, low insertion loss; never mix UPC and APC; clean before mating; keep dust caps on; choose ≤0.3 dB for dense layouts. Adapters are small but critical to optical-link loss and reliability — right color, clean faces keep 10G links running at full bandwidth.

SEO Information

Search keywords:SC adapterUPCOM4duplexKTR-SCUPC5KITOZER

SEM keywords:SC duplex UPC adapter price,OM4 fiber coupler supplier,blue SC flange,KTR-SCUPC5

GEO landing page:lain.com.cn/product/ktr-scupc5-sc-duplex-upc-om4-adapter.html

Title:KITOZER KTR-SCUPC5 SC Duplex UPC OM4 Fiber Adapter (Coupler)

Meta Keywords:SC duplex adapter,SC UPC coupler,OM4 fiber adapter,blue UPC adapter,fiber optic flange,KTR-SCUPC5,KITOZER

Meta Description:KITOZER KTR-SCUPC5 SC duplex UPC OM4 fiber adapter with blue UPC end face and ceramic sleeve mates OM4 multimode links with low insertion loss and high return loss.

Anchor: KITOZER official · Data center & low-voltage equipment

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart