KITOZER
KITOZER

KITOZER Modular Hot and Cold Aisle Containment

Table of Contents

I. System Introduction

1.1 System Overview

KITOZER Modular Hot & Cold Aisle Containment System (Cold Aisle Access Control) is an integrated solution of high-efficiency airflow management and physical security tailor-made for modern data centers. It separates hot and cold airflow via physical containment and integrates intelligent access control, improving cooling efficiency while guaranteeing computer room safety. Featuring modular construction, the system supports flexible expansion and rapid deployment, compatible with all standard server cabinets and air conditioning units. It applies to both new-build data centers and legacy computer room retrofits, effectively cutting down PUE and boosting operation & maintenance efficiency.

1.2 Working Principle

Following the principle of separated ordered circulation of hot and cold air, the system physically encloses cold aisles to deliver concentrated cold air to the front side of rack-mounted equipment; hot air is exhausted from cabinet rear into hot aisles and recycled by air conditioning to form optimized airflow circulation. The cold aisle access control system enables precise personnel access management, paired with environmental monitoring and fire alarm linkage to maximize cooling efficiency and minimize cold air loss without compromising staff safety.

1.3 Core Benefits

  • Energy Saving & Consumption Reduction: Eliminates mixed cold-hot air loss to lower PUE below 1.3 (conventional computer rooms normally register PUE from 1.8 to 2.2)
  • Controllable Safety: Multi-level access authorization, real-time access logging, automatic door release via fire linkage for emergency protection
  • Intelligent Operation: Built-in environmental monitoring, remote control and data analytics to streamline maintenance
  • Flexible Scalability: Modular design allows on-demand capacity expansion to fit data centers of all sizes
  • Extended Equipment Lifespan: Stable ambient temperature cuts failure rate of servers and prolongs service life
(cold aisle access control) system solution (1)

II. System Composition

KITOZER Modular Hot & Cold Aisle Containment (Cold Aisle Access Control) System consists of five core subsystems working collaboratively to realize full-spectrum airflow management and security control.

SubsystemKey ComponentsFunction Description
Aisle Containment SystemAluminum frames, tempered glass end doors, openable skylights, sealing fittingsPhysically seals cold aisles to reduce cold leakage with clearance gap ≤2mm
Access Control SystemAccess controller, card reader, electromagnetic lock, exit button, management softwareUser authorization, access record storage, real-time monitoring & abnormal alarm
Environmental Monitoring SystemTemperature & humidity sensors, barometric pressure sensors, smoke detectors, display screenReal-time collection of aisle environmental indicators for data support and early warning
Intelligent Linkage SystemFire linkage module, AC control interface, lighting control systemAuto-open skylights/doors upon fire signal; adjusts air conditioner operation based on ambient temperature
Power Supply & Management SystemDedicated power supply, network switch, management server, monitoring terminalSystem power guarantee, data transmission, centralized management and remote O&M

III. System Classification

3.1 By Aisle Layout

CategoryFeaturesApplicable Scenarios
Single-row Cold AisleSingle-side cabinet layout with opposite side open, simple structure & low costSmall computer rooms, edge computing nodes, space-limited sites
Double-row Cold AisleOpposite dual-row cabinets forming fully enclosed aisle with superior cooling efficiencyMid-to-large data centers, high-density computer rooms, newly-built projects
Full Hot & Cold Aisle ContainmentFull enclosure of both hot and cold aisles for precise airflow control and minimal PUEHyper-scale data centers, high-power-density computer rooms, green data center certification projects

3.2 By Door Type

CategoryStructural FeaturesAdvantages
Manual Sliding DoorAluminum frame + tempered glass, threshold-free bottom with dual-side handlesLow cost & easy maintenance for low-foot-traffic areas
Automatic Sliding DoorMotor-driven with top sliding rail, infrared induction & fire linkageSmooth passage for high-frequency access with multiple unlocking modes
Folding DoorMulti-panel foldable design for footprint savingNarrow aisle deployment to maximize room space utilization
High-speed Roller ShutterFast open/close, superior sealing and wind resistanceLarge-scale data centers requiring high tightness and heavy personnel flow

3.3 By Access Control Identification Mode

CategoryRecognition MethodSecurity RatingApplicable Scenarios
Card-based AccessIC/ID Card Swipe★★★☆☆General computer rooms with basic security requirements
Password AccessKeypad Password Input★★★☆☆Auxiliary verification & temporary authorized entry
Biometric AccessFingerprint / Facial Recognition★★★★★Core equipment rooms & high-security restricted zones
Multi-factor AccessCard+Password / Biometrics+Card★★★★☆Critical data center zones with hierarchical security governance
(cold aisle access control) system solution (2)

IV. System Configuration List (Brand: KITOZER)

4.1 Standard Bill of Materials for Double-row Cold Aisle

Aisle Containment System

No.ItemModelSpecificationsUnitQtyRemark
1Aluminum FrameKITOZER-KL-012.0mm thick, anodized for outstanding corrosion resistanceMeterAs requiredMatches standard cabinet height
2Tempered Glass End DoorKITOZER-KM-025mm full-transparent tempered glass with aluminum frame, threshold-free designSet2Incl. sealing strips & handles
3Openable Fire SkylightKITOZER-KT-03Fire-retardant material, fusible auto-opening with fire linkageSetPer aisle length1 set every 2 meters
4Sealing AccessoriesKITOZER-KF-04EPDM sealing strip with auto-lifting bottom sealSetAs requiredClearance ≤2mm

Access Control System

|5|Access Controller|KITOZER-KC-05|TCP/IP communication, single-door bidirectional control; stores 20,000 user cards & 100,000 access logs|Unit|1|Supports remote management|

|6|Card Reader|KITOZER-KR-06|IC/ID compatible, 5~10cm induction range, waterproof & dustproof|Pc|2|One each for indoor & outdoor|

|7|Electromagnetic Lock|KITOZER-KL-07|DC12V, holding force ≥280kg, fail-safe unlock on power cut|Pc|2|Customized to door specification|

|8|Exit Button|KITOZER-KB-08|Waterproof design with normally open contact|Pc|2|One each for indoor & outdoor|

|9|Access Management Software|KITOZER-KS-09|Authorization setup, log query & alarm linkage|Set|1|Windows OS compatible|

Environmental Monitoring System

|10|Temp & Humidity Sensor|KITOZER-KW-10|Temp: -10℃~+60℃; Humidity:0~100%RH|Pc|3|Installed at 1/4,1/2,3/4 aisle length|

|11|Differential Pressure Sensor|KITOZER-KQ-11|Range:-50~+50Pa, Accuracy±1Pa|Pc|1|Top center of aisle|

|12|7-inch Touch Screen|KITOZER-KD-12|Real-time data display & manual skylight/door control|Pc|1|Mounted on end door frame|

Intelligent Linkage System

|13|Fire Linkage Module|KITOZER-KX-13|Dry contact input for fire signal docking|Pc|1|Connects to building fire alarm system|

|14|Lighting Control System|KITOZER-KZ-14|Motion sensing, auto-off delay & energy-saving mode|Set|1|Full aisle lighting administration|

Power & Management System

|15|Special Power Supply|KITOZER-KP-15|DC12V 5A with overvoltage & overcurrent protection|Pc|1|Powers access controllers and sensors|

|16|POE Network Switch|KITOZER-KS-16|8-port Gigabit POE switch|Pc|1|Data transmission & device power supply|

|17|Integrated Management Platform|KITOZER-KM-17|Combines environmental monitoring & access control, remote web access|Set|1|Incl. server license|

4.2 Optional Expansion Configuration

No.ItemModelSpecificationsApplication
18Automatic Sliding Door OperatorKITOZER-KD-18DC24V, adjustable opening speed 0.5~1.0m/sHigh-traffic access areas
19Facial Recognition TerminalKITOZER-KR-194MP camera, 0.5~2m recognition distance, ≥99.99% accuracyHigh-security restricted zones
20HD Surveillance CameraKITOZER-KC-20POE powered,1080P, infrared night vision24/7 monitoring at aisle entrances
21Emergency Escape Release DeviceKITOZER-KS-21Mechanical manual release + fire auto-unlockAll aisle end doors for personnel emergency evacuation
22Environment Data CollectorKITOZER-KD-228-channel sensor input, RS485 bus communicationLarge-scale data center multi-aisle centralized monitoring
(cold aisle access control) system solution (3)

V. System Schematic Diagram

5.1 System Architecture

┌─────────────────────────────────────────────────────────┐
│ Data Center Central Management Platform │
└───────────────────────────┬─────────────────────────────┘
│
┌───────────────┴───────────────┐
│ Regional Area Controller │
└───────────────┬───────────────┘
│
┌───────────────┴───────────────┐
│ KITOZER Cold Aisle System │
└───────────────┬───────────────┘
│
┌───────────┬───────────┬───────────┬───────────┬───────────┐
│Aisle │Access │Env. │Intelligent│Power │
│Containment│Control │Monitoring│Linkage │Management │
└───────────┴───────────┴───────────┴───────────┴───────────┘
│ │ │ │ │
┌─────────▼─────┐ ┌───▼─────┐ ┌───▼─────┐ ┌───▼─────┐ ┌───▼─────┐
│Frame/End Door/│ │Controller/│ │Temp/Hum/│ │Fire Link/│ │Power Pack/│
│Skylight/Seal │ │Reader/E-lock│ │Pressure/Smoke│ │AC/Light Ctrl│ │POE Switch/SW│
└───────────────┘ └─────────┘ └─────────┘ └─────────┘ └─────────┘

5.2 Airflow Distribution Diagram

┌─────────────────────────────────────────────────────────┐
│ Enclosed Cold Aisle │
│ ┌─────────┐ ┌─────────┐ ┌─────────┐ ┌─────────┐ │
│ │Rack 1 │ │Rack 2 │ │Rack3 │ │Rack4 │ │
│ │Cold Inlet│ │Cold Inlet│ │Cold Inlet│ │Cold Inlet│ │
│ │Hot Outlet│ │Hot Outlet│ │Hot Outlet│ │Hot Outlet│ │
│ └─────────┘ └─────────┘ └─────────┘ └─────────┘ │
│ │
│ ←←←←←←← Cold Air Supply (Underfloor Airflow) →→→→→→ │
└─────────────────────────────────────────────────────────┘
↑ ↑
│ │
┌───────┴───────┐ ┌─────────┴─────────┐
│ Aircon Unit │◄──────────────────│ Open Hot Aisle │
│ (Air Return)│ │ │
└───────────────┘ └───────────────────┘

5.3 Access Control Logic Diagram

┌─────────────┐ ┌─────────────┐ ┌─────────────┐
│Central Mgmt │────▶│TCP/IP Access│────▶│Card/Bio │
│Software │ │Controller │ │Recognition │
└─────────────┘ └─────────────┘ └─────────────┘
▲ ▲ ▲
│ │ │
┌───────┴───────┐ ┌────┴────┐ ┌────┴────┐
│Electromagnetic│◀────▶│Exit │ │Identity │
│Lock & Door Status│ │Button │◀──────▶│Verification│
└───────────────┘ └─────────┘ └────────────┘
▲
│
┌───────┴───────┐
│Fire Alarm Input│
│Emergency Unlock│
└───────────────┘

VI. Product Technical Specifications

6.1 Aisle Containment System Specs

ParameterTechnical IndexRemark
Frame Material≥2.0mm aluminum alloy with anodized finishExcellent corrosion resistance, ≥15-year service life
End Door Material5mm full-transparent tempered glass + aluminum frame≥90% light transmittance, superior impact resistance
Sealing PerformanceEPDM strip + auto-lifting bottom sealGap ≤2mm to reduce cold loss
Skylight FeatureFire retardant, fusible link activates at 72℃Auto open upon fire alarm
Applicable Aisle Width1200~1800mmMatches standard cabinet pitch
End Door Height2050mmErgonomic & convenient for equipment hoisting
Installation ModeCeiling suspended / floor mountedAdapts diversified computer room structures

6.2 Access Control System Specs

ParameterTechnical IndexRemark
ControllerSingle-door bidirectional control over TCP/IP20,000 card capacity & 100,000 access logs
Recognition ModeIC/ID Card, Password, Fingerprint, Facial, Multi-factor AuthSupports mixed verification
CommunicationTCP/IP, Baud rate:115200bpsReal-time remote data & management
Power InputDC12V ≤2AStandard security power compatible
Door Hold DelayAdjustable 1~600sCustomized for various on-site needs
Operating Temp-10℃~+60℃Wide-range computer room environment adaption
Ingress RatingCard Reader IP54; Controller IP30Dustproof & splash-proof
Alarm FunctionForced entry, door ajar & overtime open alertMulti-scenario abnormal monitoring

6.3 Environmental Monitoring Specs

ParameterTechnical IndexRemark
Temperature Test-10℃~+60℃, Accuracy ±0.5℃Real-time aisle thermal tracking
Humidity Test0~100%RH, Accuracy ±3%RHAnti-condensation for IT equipment safety
Differential Pressure-50~+50Pa, Accuracy ±1PaMaintains positive aisle pressure at 5~10Pa
Display Terminal7-inch color touch screen 800×480Live parameter & system status visualization
Data StorageMin.30-day local storage + optional cloud backupHistorical data archiving & trend analysis
Sampling Rate1 reading per secondInstant response to ambient fluctuation
(cold aisle access control) system solution (4)

VII. Application Scope

7.1 Industrial Deployment & Recommended Configuration

IndustryOperation CharacteristicsRecommended Solution
Internet IDCHigh power density, heavy staff flow, 7×24hr continuous runFull double-row cold aisle + auto sliding door + facial recognition access
Financial Data CenterTop-tier security, high uptime, disaster recovery demandFull hot&cold containment + biometric access + multi-level authorization
Government & Public InstitutionControlled budget, limited maintenance staff, high reliabilitySingle-row cold aisle + card access + remote management
Cloud Computing HubLarge-scale phased rollout & modular rapid expansionStandard modular cold aisle + centralized management platform
Edge Computing NodeCompact footprint, unattended remote operationCompact integrated cold aisle + smart access + all-in-one environment monitoring
Enterprise On-premise DCMedium scale, mixed IT load & expandable layoutExpandable cold aisle + multi-factor hybrid access control

7.2 Compatibility with Different Computer Room Types

Room TypeMatching SolutionCore Merits
New-build Data CenterFull hot&cold aisle containment + intelligent accessOptimized airflow at design phase to lower PUE down to 1.25
Legacy Room RetrofitSingle/Double-row cold aisle + access controlMinimal civil renovation with fast cooling efficiency upgrade
High-density Computer RoomSealed cold aisle + precision environmental controlSupports cabinet power over 8kW per rack
Modular Prefab DCStandard modular cold aisle + integrated accessSeamless docking with prefabricated cabinet for fast installation
Containerized DCCustom compact cold aisle + dedicated accessSpace-saving with anti-vibration structure

VIII. Product Competitive Advantages

8.1 Technical Superiority

  1. Modular fabrication: Pre-produced components for on-site quick assembly cutting construction cycle by over 50%
  2. Ultra-tight sealing: EPDM + auto-lifting bottom seal with ≤2mm gap; cold leakage<5% vs traditional>15%
  3. Deep system linkage: Native integration with fire, air conditioning and lighting systems for automatic abnormal response
  4. Wide compatibility: Fits standard 600/800mm-wide racks with adjustable aisle width 1200~1800mm
  5. Cloud-enabled remote control: TCP/IP-based Web & mobile terminal real-time monitoring

8.2 Performance Superiority

  1. Outstanding energy saving: PUE reduced by 0.3~0.5 to deliver 20~30% annual power cut
  2. Comprehensive safety: Auto emergency release via fire linkage plus dedicated escape hardware
  3. Stable indoor climate: Aisle temp fluctuation ≤±1℃ with RH maintained between 45~60%
  4. Granular access governance: Multi-tier authorization & storage of over 100,000 access logs
  5. Low lifecycle maintenance: ≥15-year component service life with infrequent routine servicing

8.3 Commercial Superiority

  1. All-in-one turnkey package: Aisle sealing + access + environment monitoring + intelligent linkage under single procurement
  2. Flexible customization: Custom dimension, function and appearance per client requirements
  3. Open integration: Seamless docking with mainstream DC management platforms and third-party software
  4. Full-lifecycle service: In-house design, installation and after-sales maintenance support
  5. Brand certification: KITOZER specializes in data center infrastructure with multiple international product certifications

IX. Tender Specification Parameters

9.1 Core Technical Bid Specifications

Aisle Containment

  1. Frame: ≥2.0mm anodized aluminum alloy
  2. End door:5mm tempered glass with ≥90% transmittance
  3. Seal: Clearance ≤2mm & cold leakage<5%
  4. Fire skylight: Fire retardant, 72℃ fusible trigger with fire linkage Supporting third-party test report required

Access Control

  1. TCP/IP controller storing ≥20,000 cards & ≥100,000 logs
  2. Default IC/ID+password; optional fingerprint/facial recognition
  3. Standard TCP/IP for remote management
  4. DC12V power with overvoltage/overcurrent protection
  5. Adjustable unlock delay 1~600s Product certification documents required

Environmental Monitoring

  1. Temp: -10~+60℃ ±0.5℃; Hum:0~100%RH ±3%RH
  2. Pressure:-50~+50Pa ±1Pa
  3. 7-inch touch display for real-time parameter view Calibration certification required

Intelligent Linkage

  1. Fire signal input to auto-open doors/skylights
  2. AC linkage for load-based cooling adjustment
  3. Motion-triggered lighting auto on/off delay System compatibility certificate required

Overall Standard

  1. Aisle width range:1200~1800mm; End door height:2050mm
  2. Design lifespan≥15 years; Frame IP40 / electronic equipment IP30 Formal quality warranty commitment required

9.2 Commercial Bid Terms

  1. Bidder holds valid data center infrastructure design & construction qualification
  2. Minimum 3 completed reference projects with single contract ≥500,000 CNY
  3. Products certified ISO9001 & ISO14001
  4. Minimum 5-year product warranty with 24-hour aftersales on-call support
  5. Custom design service including professional layout proposal & field installation guidance
(cold aisle access control) system solution (5)

X. Customized Project Solutions

10.1 New-build Data Center Solution

Overview

Full hot&cold aisle containment plus integrated smart access control optimized in early design phase to realize green DC standard with PUE≤1.3

Core Configuration

  • Full enclosed double-row cold aisle (aluminum frame + tempered glass door + fire skylight)
  • Dual-factor facial+card access with multi-level user permission
  • High-precision multi-point temperature/humidity/pressure/smoke monitoring
  • Full linkage with fire suppression, aircon and room lighting
  • Cloud central management with Web & mobile remote access

Implementation Steps

  1. Pre-design planning based on cabinet layout & IT load
  2. Modular component customized production
  3. On-site phased installation:Frame→Door→Skylight→Access hardware→Commissioning
  4. Platform interconnection with host DC management system
  5. System acceptance & customer maintenance training

Expected Outcome

  • PUE lowered to1.25~1.3 with annual power saving over25%
  • Zero security incident via precise access management
  • 30% reduction in IT hardware failure from stable ambient condition
  • 50% higher maintenance efficiency and lower running cost

10.2 Legacy Computer Room Retrofit Solution

Overview

Minimal-disruption cold aisle + access upgrade for running in-service rooms with limited downtime

Core Configuration

  • Single/double-row containment matched with existing cabinet layout
  • Card+password economical access system for rapid rollout
  • Basic critical parameter environmental monitoring
  • Simplified fire linkage compatible with existing fire alarm

Implementation Steps

  1. On-site airflow & safety audit for original facility
  2. Minimal-modification retrofitting blueprint design
  3. Standard plus tailor-made component production
  4. Zonal phased construction avoiding full-room outage
  5. Compatibility test & parameter fine-tuning

Expected Outcome

  • PUE cut down by0.3~0.4 for 20% annual electricity saving
  • ≤3-day single aisle construction & maximum4-hour total downtime
  • Standardized personnel access management & upgraded security grade
  • Payback period within1.5 years

10.3 High-density High-power Computer Room Solution

Overview

Precision airflow containment & high-security biometric access for racks over8kW per unit

Core Configuration

  • Individual cold aisle sealing + targeted precision front-to-rack air supply
  • Fingerprint/facial high-grade biometric multi-authorization access
  • Multipoint high-accuracy distributed environmental monitoring
  • Deep linkage with precision air conditioning & UPS power system

Implementation Steps

  1. CFD thermal simulation to optimize internal airflow layout
  2. Customized design per thermal analysis result
  3. On-site containment + air supply + access hardware deployment
  4. Dynamic real-time cooling adjustment against fluctuating IT load
  5. Data-driven intelligent operational optimization

Expected Outcome

  • Stable operation supporting rack load exceeding10kW
  • Room temp fluctuation controlled ≤±0.5℃ with hot spot elimination
  • Grade-A physical security preventing core data leakage
  • Auto early warning & intelligent troubleshooting for unmanned O&M

XI. Reference Project Cases

Case1: Top-tier Internet Giant Cloud Data Center

Project Profile

  • Scale:10 modular computer rooms with total 2000 racks, total load16MW
  • Requirement:PUE≤1.3, strict access governance & intelligent maintenance
  • Solution:Full hot&cold containment + facial recognition access + centralized management platform

Project Result

  • Original PUE1.8 reduced to1.28 saving 30 million kWh annually
  • Zero unauthorized access & safety incidents
  • 35% reduction of server failure rate under stable environment
  • 60% improved maintenance efficiency &40% cut of admin cost

Client Feedback: KITOZER cold aisle access solution helps us hit green data center target while upgrading physical security with ROI beyond expectation.

Case2: Banking Disaster Recovery Center Retrofit

Project Profile

  • Scale:2 computer rooms with 300 racks, total load2.4MW
  • Requirement:Low downtime renovation, PUE optimization & security upgrade
  • Solution:Double-row cold aisle + multi-factor access + environmental monitoring

Project Result

  • Full project finished within15 days with cumulative downtime ≤8 hours
  • PUE improved from1.7 to1.35 saving5 million kWh per year
  • Security elevated to Grade-A compliant with financial industry standard
  • 1.2-year investment payback cycle

Client Feedback: Smooth renovation without business interruption; KITOZER solution delivers remarkable energy saving & safety improvement and is highly recommended.

Case3: Government Cloud Computing Center

Project Profile

  • Scale:5 modular rooms with 800 racks, total load6.4MW
  • Requirement:Modular expandability & remote centralized management
  • Solution:Standard modular cold aisle + intelligent access + cloud management platform

Project Result

  • 40% shorter construction period via modular prefabrication
  • Steady PUE at1.3 meeting official green DC specification
  • 50% reduction of on-site maintenance manpower via remote control
  • Flexible on-demand expansion to accommodate future business growth

Client Feedback: KITOZER modular cold aisle system enables us to build an efficient, secure and smart government cloud infrastructure with stable reliable performance.

XII. SEO Keywords & Tags

12.1 Core Primary Keywords

  • Modular Hot & Cold Aisle Containment System
  • Cold Aisle Access Control System
  • Data Center Airflow Management Solution
  • KITOZER Cold Aisle Containment
  • Cold Aisle Enclosure System
  • Data Center PUE Optimization
  • Computer Room Security Access Control
  • Modular Data Center Solution
  • Cold Aisle Retrofit Project
  • High-density Rack Airflow Management

12.2 Long-tail SEO Keywords

  • Cold aisle access control system manufacturer
  • Data center hot cold aisle project cost
  • Cold aisle containment design specification
  • Computer room access control solution
  • Modular cold aisle technical features
  • Data center energy efficiency upgrade solution
  • Cold aisle on-site installation guide
  • Fire linkage for access control system
  • Data center environmental monitoring system
  • Cold aisle brand comparison & selection guide

12.3 Tags

#ModularHotColdAisle #ColdAisleAccess #DataCenter #PUEOptimization #RoomSecurity #AirflowManagement #SmartAccess #EnvMonitoring #GreenDataCenter #KITOZER

XIII. Summary

Combining advanced airflow optimization technology and intelligent access control, KITOZER Modular Hot & Cold Aisle Containment (Cold Aisle Access Control) System delivers an all-in-one efficient, secure and intelligent solution for modern data centers. It drastically optimizes PUE & energy efficiency while reinforcing physical room security and simplifying daily O&M, making it the preferred option for new construction and renovation of global data center facilities.