Table of Contents
ToggleI. System Introduction
1.1 Technical Background
Driven by high-density IT equipment deployment and surging computing power demand in modern data centers, conventional open computer rooms suffer severe drawbacks including hot-cold air mixing, poor cooling efficiency and excessively high PUE. KITOZER Modular Hot & Cold Aisle Containment System with cold aisle skylights precisely separates hot and cold airflow via physical partitioning to build an efficient and stable airflow layout, serving as core infrastructure for energy-saving green data center construction and intelligent O&M.
1.2 System Definition
KITOZER Modular Cold Aisle Skylight Containment is a hermetic airflow management solution built on modular design philosophy. Cabinets are arranged back-to-back to form fully enclosed cold aisles equipped with dedicated top skylight assemblies. Paired with in-row or under-floor air supply CRAC units, cold air is directionally delivered to IT equipment air intake while hot exhaust is discharged from cabinet rear into hot aisles, eliminating cross-mixing of hot and cold air and drastically boosting cooling efficiency and energy utilization rate.
1.3 Core Values
- Energy Conservation: Cold air utilization improved by 35%~45%, PUE reduced below 1.2
- Precise Temperature Control: Cold aisle temperature stabilized at 18~22℃ with intra-aisle temperature gap ≤1℃ to eliminate hotspots
- Intelligent Linkage: Seamless integration with fire alarm and BMS environmental monitoring for full computer room safety guarantee
- Flexible Scaling: Modular structure enables phased capacity expansion alongside business growth to lower upfront CAPEX
- Fast Deployment: Factory prefabricated components for on-site assembly, cutting construction cycle by over 50%

II. System Composition
KITOZER Cold Aisle Skylight System consists of ten core subsystems to realize integrated airflow regulation and ambient control.
| System Module | Core Components | Function Description |
|---|---|---|
| Base Frame System | Rack support frame, aisle upright posts, cross beams, connecting fittings | Forms main aisle bearing structure; load capacity ≥800kg/㎡, seismic resistance up to Grade 8~9 |
| Cold Aisle Skylight System | Flat-top skylight, turnover skylight, fixed skylight, fire linkage actuator | Top enclosure & automatic emergency opening; air leakage rate<0.5%, fully compliant with fire codes |
| Aisle Door System | Single/double leaf door, automatic door closer, magnetic/pneumatic lock, EPDM sealing strip | End-of-row air sealing with triple protection: normally closed + auto-close + buffered tight seal; air tightness ≥98% |
| LED Lighting System | Recessed LED lamp, human-body motion sensor switch, backup power module | Uniform illumination ≥300Lux, auto on/off by motion detection, ≥90min emergency lighting upon power failure |
| Environmental Monitoring System | Temp & humidity sensor, smoke detector, differential pressure transducer | Real-time ambient data acquisition; temp accuracy ±0.5℃, RH accuracy ±3%RH |
| Intelligent Control System | Main controller, linkage interface module, remote management software | Auto skylight regulation, fire interlock, status monitoring & remote O&M |
| Full Sealing System | Top weather strip, door sealing gasket, cabinet side baffle, cable grommet | Omni-directional sealing to avoid cold leakage and guarantee precise airflow route |
| Leveling Support System | Height-adjustable foot pad, horizontal regulator, anti-vibration cushion | Compensates uneven floor with ±50mm adjustment range for level & stable aisle installation |
| Fire Linkage System | FuseLink thermal fusible unit, DC24V electric actuator, fire signal dry contact | Full skylight auto-opening within 10s on fire alarm; compliant with NFPA & GB50174 |
| Auxiliary O&M System | Maintenance access panel, observation window, cable trough, earthing assembly | Facilitates routine inspection, cable routing and safe equipment grounding |

III. System Classification
3.1 By Structural Layout
| Category | Structural Features | Applicable Scenarios |
|---|---|---|
| Flat-top Cold Aisle Skylight | Skylight stands 350~450mm above cabinet top with flat surface, fits standard cabinet layout | New-build data centers & standardized modular computer rooms requiring aesthetics & universal compatibility |
| Ceiling-through Skylight | Skylight top flush-mounted with ceiling to maximize vertical space | Low-ceiling legacy room retrofits needing concealed installation |
| Low-profile Compact Skylight | Overall height ≤270mm for space-saving compact setup | Ultra-high-density racks & space-limited edge computing nodes |
3.2 By Skylight Opening Type
| Skylight Type | Opening Mode | Technical Features | Application |
|---|---|---|---|
| Fixed Skylight | Non-openable | Fully sealed, leakage<0.3%, simple robust construction | Non-critical fire zones & small-budget small computer rooms |
| Turnover Hinged Skylight | Electric / manual tilting | Opening angle ≥90°, clear internal height ≥2000mm for easy equipment servicing | Mainstream data centers balancing tight sealing & maintainability |
| Horizontal Sliding Skylight | Motor-driven horizontal slide | Zero protruding structure after opening to save overhead space | Low-ceiling computer rooms demanding maximum working clearance |
| Multifunctional Integrated Skylight | Composite all-in-one design | Integrated lighting, environmental sensing and fire linkage | Intelligent green data centers preferring compact integrated solution |
3.3 By Project Scale
| Scale | Qty of Cabinets | Total Aisle Length | System Characteristics |
|---|---|---|---|
| Small-size System | 3~8 racks | ≤4m | Single independent unit with simplified configuration & ultra-fast installation |
| Mid-size System | 9~24 racks | 4~12m | Multi-module cascaded layout with partition control and redundant design |
| Large-size System | ≥25 racks | >12m | Modular expandable cluster management supporting docking with DCIM platform |
IV. Bill of Materials (Brand: KITOZER)
| No. | Item | Model | Brand | Unit | Qty | Specification & Function |
|---|
Part 1: Core Cold Aisle Skylight Assembly
1|Flat Turnover Skylight|KT-CTS-1300|KITOZER|Set|Per project|1300×600×350mm; 1.5mm cold rolled steel frame, 3mm UL94-V0 fireproof polycarbonate panel|
2|Skylight Mount Bracket|KT-CTS-BK-01|KITOZER|Set|Per project|Matched for 1300mm width skylight, load ≥250kg/㎡, anti-seismic structure|
3|DC Electric Actuator|KT-CTS-MT-24|KITOZER|Pc|Per project|DC24V, thrust ≥500N, full stroke ≤10s, dedicated fire interlock port|
4|FuseLink Thermal Fusible Unit|KT-CTS-FL-100|KITOZER|Pc|Per project|Auto fuse at 100℃, response ≤3s with redundant backup design|
Part 2: Aisle Frame Components
5|Aisle Upright Post|KT-CTF-CL-2200|KITOZER|Pc|Per project|2200mm height,1.5mm cold rolled steel, single post load ≥1000kg, ±50mm height adjustable|
6|Cross Beam|KT-CTF-BM-1300|KITOZER|Pc|Per project|1300mm length, customized for dual-row 600mm-wide cabinet arrangement|
7|Side Enclosure Panel|KT-CTF-SP-2200|KITOZER|Pc|Per project|2200×600mm flame retardant sheet, light transmittance ≥90%|
Part3: Aisle Door Assembly
8|Single Leaf Access Door|KT-CTD-SD-1300|KITOZER|Leaf|2|1300×2200mm; tempered glass + aluminum frame with full EPDM perimeter gasket|
9|Adjustable Door Closer|KT-CTD-CL-01|KITOZER|Pc|4|Speed adjustable, 15° buffer angle, holding torque ≥5N·m|
10|Magnetic Door Catch|KT-CTD-MS-01|KITOZER|Pc|4|Magnetic pull ≥80N to maintain tight door closure and reduce cold leakage|
Part4: Intelligent Control Unit
11|Central Aisle Controller|KT-CTC-H-01|KITOZER|Unit|1|Supports 8-channel skylight output & 4-channel fire signal input, RS485 Modbus communication|
12|Temp & Humidity Sensor|KT-CTC-TH-01|KITOZER|Pc|2|Range:-10~60℃(±0.5℃);0~100%RH(±3%RH)|
13|Photoelectric Smoke Detector|KT-CTC-SD-01|KITOZER|Pc|2|Sensitivity:0.05~0.15%obs/m, alarm response ≤5s|
Part5: Lighting & Auxiliary Parts
14|Recessed LED Linear Lamp|KT-CTL-LED-1200|KITOZER|Set|Per project|1200mm, SMD3030,6500K, Ra≥80,18W|
15|PIR Motion Sensor|KT-CTL-IS-01|KITOZER|Pc|2|Detection range 3~5m, auto-off delay adjustable:1~30min|
16|EPDM Sealing Strip|KT-CTS-ST-01|KITOZER|Meter|Per project|Temp resistance:-40~120℃, compression rebound ≥70%|
17|Earthing Assembly|KT-CTA-GD-01|KITOZER|Set|4|Ground resistance ≤4Ω for frame & cabinet equipotential bonding|

V. System Principle Diagrams
5.1 Airflow Distribution Schematic
┌─────────────────────────────────────────────┐
│ Computer Room Ceiling │
│ ┌─────────────────────────────────────┐ │
│ │ KITOZER Cold Aisle Skylight │ │
│ │ ┌──┐ ┌──┐ ┌──┐ ┌──┐ │ │ Hot Aisle
│ │ │SKY││SKY││SKY││SKY│ │ │ ↑
│ │ └──┘ └──┘ └──┘ └──┘ │ │ │
│ └─────────────────────────────────────┘ │ │
│ │ │
│ ┌─────────────────────────────────────┐ │ │
│ │┌─┐┌─┐┌─┐┌─┐┌─┐┌─┐ │ │ │
│ ││IT││IT││IT││IT││IT││IT│Equipment │ │ │
│ │└─┘└─┘└─┘└─┘└─┘└─┘ │ │ │
│ │ ┌─────────────────────────────┐ │ │ │
│ │ │Raised Floor / Air Plenum │ │ │ │
│ │ └─────────────────────────────┘ │ │ │
│ └─────────────────────────────────────┘ │ │
│ │ │
│ ┌─────────────────────────────────────┐ │ │
│ │ In-row CRAC Unit │ │ │
│ └─────────────────────────────────────┘ │ │
└─────────────────────────────────────────────┘ │
Cold Air Supply →→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→┘
Airflow Description
- Cold air is blown into cold aisle bottom via underfloor or in-row air-conditioning system
- Stable laminar cold air uniformly feeds front intake of all IT servers inside sealed aisle
- Hot exhaust after heat absorption is discharged from cabinet rear into open hot aisle
- Hot air rises to ceiling and is sucked back by CRAC return air inlet for re-cooling to form closed circulation
- Skylights stay fully closed under normal operation to guarantee precise airflow routing; auto open on fire for smoke exhaust & fire suppression gas diffusion
5.2 Control Logic Diagram
┌─────────────┐ ┌─────────────┐ ┌─────────────┐
│Fire Alarm Host│ │BMS Monitoring│ │Remote Cloud │
└──────┬──────┘ └──────┬──────┘ └──────┬──────┘
│ │ │
▼ ▼ ▼
┌─────────────────────────────────────────────────────┐
│ KITOZER Central Controller │
└───────┬──────────┬────────────┬─────────────────────┘
│ │ │
▼ ▼ ▼
┌────────┐ ┌─────────┐ ┌────────────┐
│Skylight│ │Lighting │ │Env Monitor │
│Actuator│ │Driver │ │Module │
└───┬────┘ └───┬────┘ └────┬───────┘
│ │ │
▼ ▼ ▼
┌────────┐ ┌────────┐ ┌────────────┐
│Aisle │ │LED Lamp│ │Temp/Hum/Smoke│
│Skylight│ │System │ │Detectors │
└────────┘ └────────┘ └────────────┘
Control Logic
- Normal status: Controller receives real-time ambient data and keeps all skylights tightly closed for cold sealing
- Fire linkage: Triggered by fire panel signal or FuseLink thermal melting, all skylights synchronously open within 10s
- Manual override: Local cabinet & remote software manual control reserved for maintenance access
- Real-time feedback: Skylight position & environmental data uploaded continuously to BMS and remote management platform

VI. Technical Specifications
6.1 Core Skylight Technical Data
| Parameter | Specifications | Remarks |
|---|---|---|
| Standard Dimension | 1300×600×350mm; matched for 600mm standard cabinet; applicable aisle width:1200~1350mm | Custom dimension available per project |
| Construction Material | Frame:1.5mm bent & welded cold rolled steel; Panel:3mm UL94-V0 PC fireproof sheet; Seal:EPDM weather-resistant rubber | Class A fire resistance, UV resistant, service life≥10 years |
| Performance Index | Air leakage<0.5%; Load ≥250kg/㎡; Opening angle≥90%; Full stroke≤10s | Compliant with GB50174 & NFPA standards |
| Electrical Parameter | Rated DC24V; Power consumption ≤20W/unit; Dry contact/DC24V dual fire input | Compatible with mainstream fire alarm systems |
| Ambient Tolerance | -10~60℃,10~90%RH(non-condensing); Seismic Grade 8~9 | Third-party anti-seismic certification available |
| Certification | UL94-V0, CE, ISO9001 | Domestic & international safety approval |
6.2 Frame & Door / Auxiliary Specs
| Item | Technical Index | Note |
|---|---|---|
| Aisle Frame | Post height:2200~2600mm; Beam length:1300mm; 1.5mm steel; single post load≥1000kg, ±50mm adjustable | Field leveling adaption |
| Access Door | 1300×2200mm;5mm laminated tempered glass + aluminum frame; full EPDM surrounding seal | Light transmittance≥90%, meets GB15763.2-2005 |
| LED Lighting | SMD3030,6500K,≥300Lux,Ra≥80,PIR auto-control | ≥80% energy saving vs fixed lighting |
| Environmental Sensors | Temp:-20~80℃(±0.5℃);RH:0~100%RH(±3%RH);Smoke:0.05~0.15%obs/m | Over-limit threshold alarm function |

VII. Application Scope
KITOZER Cold Aisle Skylight System is widely deployed across all types of IDC & enterprise computer rooms with outstanding advantages in below sectors:
7.1 Data Center Industry
- New-build large-scale IDC: Build certified green DC with PUE<1.2 via optimized airflow containment
- Legacy room renovation: Minimal civil reconstruction to boost cooling efficiency and cut OPEX
- Prefabricated micro-module DC: Matches modular prefab cabinet for rapid on-site rollout & flexible expansion
- Edge computing hub: Compact footprint design for space & power restricted edge scenarios
7.2 Industrial Vertical Application
| Industry | Operating Features | Project Benefits |
|---|---|---|
| Financial Data Center | 24/7 non-stop running, ultra-high reliability | Precise thermal stabilization + fire interlock for zero downtime |
| Internet Cloud IDC | High rack power density & variable computing load | Modular scalable design to follow business expansion & reduce power cost |
| Government & SOE | Strict industry compliance & long-term stable operation | Full GB50174 compliant with optimized whole lifecycle cost |
| Healthcare IT Room | Mission-critical data & zero data loss requirement | Dual redundant design with fire safety protection |
| Telecom Operator | Distributed multi-site deployment & centralized O&M | Cloud remote monitoring to cut on-site maintenance expense |
7.3 Special Scenarios
- High-altitude computer room: Barometric pressure adaptive design for stable airflow
- High ambient-temperature site: Reinforced insulation & sealing to lock target cold aisle temperature
- High-density AI/Supercomputing room: Effective hotspot elimination under extreme high rack power
- Low-noise sensitive zone: Optimized airflow layout to lower CRAC running noise

VIII. Core Product Advantages
###8.1 Energy Saving Advantage
- Cold air utilization improved by 35~45% via complete hot-cold isolation to eliminate waste cooling loss
- PUE reduced from traditional 1.8~2.0 down below 1.2 with annual massive electricity saving
- Lower air conditioner running load to extend CRAC lifespan and reduce maintenance expenditure
###8.2 Intelligent & Safe Advantage
- Triple fire protection: FuseLink thermal fuse + DC24V electric actuator + fire dry contact; full opening within10s
- Full-spectrum real-time monitoring: Temp/RH/smoke/skylight status with early risk pre-alarm
- Mobile APP+PC remote management to slash manual inspection workload
- Multi-level user access permission to avoid erroneous system operation
###8.3 Flexible Expandability
- Modular unit based on 2-cabinet standard; add/remove modules without interrupting existing operation
- Prefabricated factory production for on-site splicing, shorten construction over 50%
- Universal compatibility with mainstream cabinets, air-conditioner and BMS to protect existing asset investment
- Reserved expansion interface for future functional upgrade and system extension
###8.4 Reliable Quality Advantage
- Heavy-duty frame ≥800kg/㎡ bearing, Grade8~9 anti-seismic with third-party certification
- Full Class A flame retardant material complying with GB & UL fire standards
- Core component service life≥10 years to reduce spare part replacement cost
- IP54 ingress protection against dust & moisture for harsh computer room environment

IX. Tender Specification Parameters
###9.1 Core Technical Bid Specifications
- Cold Aisle Skylight System
- Modular turnover skylight, single module dimension ≥1300×600×350mm
- Frame ≥1.5mm cold rolled steel; panel ≥3mm UL94-V0 fireproof polycarbonate sheet
- Total air leakage<0.5%; door full EPDM sealing with air tightness≥98%
- Dual fire trigger:100℃ FuseLink fuse + DC24V fire signal; auto open within10s, tilt≥90°
- Bearing ≥250kg/㎡ to support maintenance staff standing operation
- Control System Requirements
- Local manual / auto + remote three control modes available
- Dual fire input: dry contact & DC24V for universal fire alarm docking
- Built-in temp/humidity/smoke detection: Temp ±0.5℃, RH ±3%RH
- RS485 Modbus communication for seamless BMS integration
- Backup power keeps controller working ≥30min after main power cut to secure fire function
- Safety & Environmental Standard
- Full Class A fireproof material with UL94-V0 certification
- RoHS compliant non-toxic raw material
- Pass Grade8~9 seismic third-party testing
- Overall protection rating ≥IP54
###9.2 Commercial & Aftersales Terms
- Manufacturer certified with ISO9001 & ISO14001
- Minimum 5-year product warranty + lifetime paid maintenance service
- Professional installation team for field erection, commissioning and customer training
- Complete document package: system schematic, installation & O&M manual
- Technical support response within 2 working hours; field service within 48 hours upon fault report
X. Customized Project Solutions
###10.1 Project Design Flow
| Phase | Work Content | Deliverables |
|---|---|---|
| Requirement Survey | Room dimension, cabinet quantity, rack power density, AC & fire specification | Requirement Specification Document |
| Solution Design | Aisle layout, skylight type, control & sealing scheme | Design drawing + 3D renderings |
| Product Selection | Skylight/Frame/Control/Auxiliary BOM | Detailed quotation & configuration list |
| Construction Draft | Mounting position, wiring layout | Construction drawing & installation guide |
| On-site Execution | Frame assembly, skylight fitting & system joint debugging | Acceptance report |
| User Training | Operation, daily maintenance & troubleshooting | Training record & O&M handbook |
###10.2 Typical Scenario Solutions
####10.2.1 New-build Large IDC
- Adopt flat turnover skylight for dual-row cabinet, standard 1300mm aisle width
- Intelligent control connected with DCIM platform for centralized monitoring
- Full Class A fireproof material complying with GB50174-2017
- Design cold aisle:18~22℃, intra-row temp gap ≤1℃, final PUE<1.2 Result: Cold efficiency up 45%, annual power saving over 21 million kWh; space utilization +30%; remote O&M cuts labor cost>60%
####10.2.2 Legacy Computer Room Retrofit
- Low-profile compact skylight without modifying original building structure
- Matches existing CRAC equipment to save air conditioner replacement investment
- Independent controller docking with original fire system; phased construction to avoid service interruption Result: Cooling efficiency+35%,PUE down from1.8 to below1.4; full renovation within 2 weeks; payback period ≤1.5Y, long-term OPEX reduced>40%
####10.2.3 Prefabricated Micro-module DC
- Integrated design matched with prefab cabinet; full factory pre-assembly
- All-in-one embedded lighting, sensing & fire linkage, N+X redundant design
- Reserved expansion port for future capacity growth Result: Project cycle cut70% from months to weeks; MTTR shortened within30min; flexible incremental investment to avoid overcapacity waste
XI. Project Reference Cases
###Case1: Top Internet Giant South China Cloud Data Center
- Profile:10 micro-modules,240 cabinets, total load 12MW, rack power up to20kW/rack; original PUE=1.8 with severe hotspot issue
- Solution:KITOZER flat turnover cold aisle skylight + in-row CRAC full air separation
- Outcome:PUE dropped to1.18, annual saving18 million kWh (≈CNY12.6M electricity cost); aisle temp stabilized at20±1℃, server failure rate -60%; fire linkage response ≤8s, passed GB & NFPA certification; field inspection cost down70% via remote smart O&M
###Case2: Provincial Government Cloud Retrofit Project
- Profile:Original80 racks expanded to120 racks, rack density up to15kW/rack; old room low cooling efficiency & hotspots
- Solution:Low-profile compact KITOZER skylight installed in two construction phases compatible with existing AC
- Outcome:15-day construction without government service suspension; cooling+38%,PUE from1.7→1.35,annual save6.5 million kWh; inlet temp uniformity up90%, payback=1.2Y,OPEX-42%
###Case3: Financial Disaster Recovery DC
- Profile:60 racks with 2N redundant architecture requiring 99.999% uptime & strict financial compliance
- Solution:Integrated multifunctional skylight with embedded lighting/sensing/fire linkage + dual redundant control
- Outcome:System reliability reaches 99.999% meeting finance standard; cold utilization+42%,PUE=1.22,annual save8 million kWh; fire response ≤6s with twice risk pre-warning; fault pinpoint within10s,MTTR<20min
XII. SEO Keywords & Tags
###12.1 Core Primary Keywords
- Modular Hot Cold Aisle Containment System
- Cold Aisle Skylight
- KITOZER Cold Aisle Solution
- Data Center Cold Aisle Containment
- Hermetic Cold Aisle Airflow Management
- Green DC PUE Optimization
- Cold Aisle Fire Interlock System
- Modular Data Center Retrofit
###12.2 Long-tail SEO Keywords
- Cold aisle skylight manufacturer & supplier
- Cold aisle system quotation & price
- Data center cold aisle design specification
- Legacy computer room cold aisle retrofit plan
- Cold aisle installation standard & technical parameter
- Cold aisle project application case & advantage
- Cold aisle working principle
###12.3 Hashtags
#KITOZERColdAisle #ModularAisleContainment #ColdAisleSkylight #DataCenterEnergySaving #AirflowManagement #GreenDataCenter #PUEOptimization #FireInterlock #IntelligentO&M #ComputerRoomRetrofit