Table of Contents
ToggleI. System Introduction
The KITOZER Modular Single-Row Cold Aisle Containment System is a high-efficiency airflow management solution specially designed for small and medium-sized data centers and computer rooms. Adopting a linear single-row cabinet layout, it forms an independent cold air zone through enclosed cold aisle containment. Cooperated with in-row precision air conditioners for proximal cooling, it completely isolates cold and hot airflow, eliminates local hotspots, significantly improves cooling efficiency, and reduces the PUE value to the range of 1.3-1.5. Featuring a modular design concept, the system supports rapid deployment (installation completed within several hours) and flexible expansion, making it ideal for space-limited scenarios with 6-12 cabinets, such as government and enterprise branch computer rooms, primary and secondary school campus computer rooms, hospital outpatient computer rooms, and medium-sized enterprise headquarters IT computer rooms.
Core Working Principle
Cold air is delivered to the enclosed cold aisle via in-row precision air conditioners or raised floors. The cold air enters IT equipment through cabinet mesh doors and absorbs heat, then the heated hot air is exhausted from the rear of cabinets to the open hot aisle, and finally recycled and processed by the air conditioner return air outlet to form a precise airflow circulation. The cold air utilization rate is increased to over 90%.
II. System Composition
| System Module | Core Components | Function Description |
|---|---|---|
| Cold Aisle Containment System | Aisle end doors (sliding/ double doors), aisle top plates, sealing rubber strips, partition columns | Form a fully physical enclosed space to prevent cold and hot air mixing, with cold air leakage rate <5% |
| Cabinet System | Standard server cabinets, mesh doors, blanking panels, cable organizers | Provide installation space for IT equipment, optimize airflow paths and eliminate airflow short circuits |
| Cooling System | In-row precision air conditioners, temperature sensors, airflow distributors | Realize proximal cooling, precisely control cold aisle temperature at 18-22℃ with temperature difference ≤±1℃ |
| Power Supply & Distribution System | Precision distribution cabinets, UPS modules, PDU, battery packs | Provide stable and reliable power supply, support N+1 redundant configuration to ensure continuous system operation |
| Monitoring & Management System | Temperature and humidity sensors, smoke detectors, access control system, intelligent management platform | Real-time monitoring of aisle environment, automatic alarm for abnormalities, and support remote monitoring and management |
| Auxiliary System | Emergency lighting, fire linkage devices, ventilation system | Guarantee personnel safety, comply with computer room fire protection specifications, and automatically activate ventilation in emergencies |

III. System Classification
1. Classification by Sealing Degree
| Type | Structural Features | Applicable Scenarios | Energy Efficiency Ratio |
|---|---|---|---|
| Fully Enclosed Single-Row Cold Aisle | Full sealing with end doors, top plates and side plates for complete cold and hot air isolation | High-density cabinets (single cabinet power density ≤5kW) with high cooling efficiency requirements | ★★★★★ |
| Semi-Enclosed Single-Row Cold Aisle | End doors and top plates sealed, side plates open | Medium and low-density cabinets, balancing heat dissipation and maintenance convenience | ★★★★☆ |
| Simplified Enclosed Single-Row Cold Aisle | Only end doors sealed, top plates optional | Scenarios with limited budget and general cooling efficiency requirements | ★★★☆☆ |
2. Classification by Cooling Mode
| Type | Cooling Equipment | Advantages | Applicable Environment |
|---|---|---|---|
| Air-Cooled Single-Row Cold Aisle | Air-cooled in-row air conditioner | Simple installation, no water pipe required, suitable for waterless computer rooms | Ordinary computer rooms without centralized water cooling system |
| Water-Cooled Single-Row Cold Aisle | Water-cooled in-row air conditioner + CDU | High cooling efficiency, lower PUE (1.2-1.3) | High-density computer rooms with centralized water cooling system |
| Free-Cooling Fluorine Pump Type | Fluorine pump in-row air conditioner | Utilize natural cold sources, energy saving rate over 30% | Cool climate areas with low annual average temperature |
3. Classification by Scale
| Scale | Number of Cabinets | Load Power | Aisle Length | Applicable Scenarios |
|---|---|---|---|---|
| Small-Scale Single-Row Cold Aisle | 3-6 units | 10-25kW | 3-6m | Small enterprises, branch computer rooms |
| Medium-Scale Single-Row Cold Aisle | 6-12 units | 25-50kW | 6-12m | Medium-sized enterprises, government departments, hospitals |
| Large-Scale Single-Row Cold Aisle | 12-24 units | 50-100kW | 12-24m | Large enterprises, data center edge nodes |
IV. Standard System Configuration List (Brand: KITOZER)
| No. | Product Name | Model | Brand | Quantity | Technical Specifications |
|---|---|---|---|---|---|
| I. Cold Aisle Containment Components | |||||
| 1 | Aisle End Door | KT-CD-1200 | KITOZER | 2 Sets | 1200mm width, frameless explosion-proof tempered glass, aluminum alloy frame, sliding design with door lock |
| 2 | Aisle Top Plate | KT-CT-1200 | KITOZER | By Meter | 1200mm width, composite metal material, light transmittance 85%, Class A fire rating, load capacity ≥100kg/㎡ |
| 3 | Sealing Rubber Strip | KT-CS-01 | KITOZER | Custom Quantity | High temperature resistance (-30℃~80℃), waterproof, anti-aging, excellent sealing performance |
| 4 | Partition Column | KT-CP-2000 | KITOZER | Custom Quantity | 2000mm height, 1.5mm cold-rolled steel plate, electrostatic spraying surface, seamless connection with cabinets |
| II. Cabinet System | |||||
| 5 | Standard Server Cabinet | KT-RACK-600 | KITOZER | 6-12 Units | 2000×600×1100mm, seven-fold profile main frame, 2.0mm SPCC steel plate, mesh door opening rate ≥75% |
| 6 | Blanking Panel | KT-BP-01 | KITOZER | Custom Quantity | Cabinet-matched, 1.0mm cold-rolled steel plate, for sealing unused U positions |
| 7 | Cable Organizer | KT-WM-01 | KITOZER | 1 Pcs Per Cabinet | 19-inch standard installation, metal material, supporting horizontal and vertical cable management |
| III. Cooling System | |||||
| 8 | In-Row Precision Air Conditioner | KT-CA-20 | KITOZER | 1-2 Units | 20kW cooling capacity, frequency conversion control, precise temperature and humidity control, hot-swappable design |
| 9 | Temperature Sensor | KT-TS-01 | KITOZER | 2-4 Pcs | Measuring range: -10℃~50℃, accuracy ±0.5℃, RS485 communication |
| IV. Power Supply & Distribution System | |||||
| 10 | Precision Distribution Cabinet | KT-PD-630 | KITOZER | 1 Set | 630A input, multiple 16A/32A outputs, remote monitoring support, overload and short circuit protection |
| 11 | UPS Module | KT-UPS-20 | KITOZER | 1+1 Sets | 20kW power module, modular hot-swappable design, efficiency ≥95% |
| 12 | PDU | KT-PDU-16 | KITOZER | 1 Pcs Per Cabinet | 16A input, 10-channel 10A output, lightning protection and overload protection |
| 13 | Battery Pack | KT-BAT-12 | KITOZER | Custom Quantity | 12V/100Ah maintenance-free lead-acid battery, supporting 1-8 hours long delay configuration |
| V. Monitoring & Management System | |||||
| 14 | Intelligent Management Platform | KT-MP-01 | KITOZER | 1 Set | Web access supported, real-time monitoring of temperature, humidity, power parameters and alarm information |
| 15 | Temperature & Humidity Sensor | KT-TH-01 | KITOZER | 2 Pcs | Temperature: 0-50℃, Humidity: 20%-90%RH, humidity accuracy ±2%RH |
| 16 | Smoke Detector | KT-SD-01 | KITOZER | 1 Pcs | Photoelectric type, sensitivity 0.65-1.5dB/m, fire linkage supported |
| 17 | Access Control System | KT-AC-01 | KITOZER | 1 Set | Card + password verification, remote door opening and record query supported |
| VI. Auxiliary System | |||||
| 18 | Emergency Lighting | KT-EL-01 | KITOZER | 2 Pcs | LED light source, auto start after power failure, continuous lighting ≥90 minutes |
| 19 | Fire Linkage Device | KT-FA-01 | KITOZER | 1 Set | Linked with aisle doors, automatically open end doors to release pressure in case of fire |
| 20 | Ventilation System | KT-VS-01 | KITOZER | 1 Set | Forced ventilation in emergencies to ensure personnel safety |

V. System Schematic & Airflow Principle
Airflow Flow Chart
In-row Air Conditioner → Enclosed Cold Aisle (Cold Pool) → Cabinet Mesh Door → IT Equipment Heat Absorption → Cabinet Rear Door → Open Hot Aisle → Air Conditioner Return Air Inlet → Cooling & Recirculation
Airflow Operation Description
1. The in-row air conditioner delivers cold air to the enclosed cold aisle to form an independent cold pool with stable cold air concentration.
2. Cold air uniformly enters IT equipment through cabinet mesh doors to take away operating heat.
3. The heated hot air is discharged from the cabinet rear to the open hot aisle area.
4. Hot air rises naturally and is recovered by the air conditioner return air inlet, then cooled and recycled to the cold aisle.
5. A high-efficiency closed-loop airflow circulation is formed without cold and hot air mixing, increasing cooling efficiency by over 30%.
VI. Core Technical Parameters
1. Cold Aisle Containment System Parameters
| Parameter Item | Technical Index | Remark |
|---|---|---|
| Aisle Width | Standard 1200mm, customizable 800-1800mm | Adapt to 1-2 anti-static floor widths |
| Aisle Height | 2000-2400mm | Adapt to standard cabinet height |
| End Door Material | ≥8mm frameless explosion-proof tempered glass + aluminum alloy frame | Light transmittance ≥90%, high impact resistance |
| Top Plate Material | Composite metal plate with anti-static coating | Class A fire rating, load capacity ≥100kg/㎡ |
| Sealing Performance | Cold air leakage rate <5%, excellent air tightness | Comply with GB 50174 Data Center Design Specification |
| Fire Rating | Overall Class A fire protection | Meet computer room fire protection requirements |
| Installation Method | Modular splicing, no welding required | Fast installation, detachable and expandable |
2. Cabinet System Parameters
| Parameter Item | Technical Index | Remark |
|---|---|---|
| Size Specification | Standard 2000×600×1100mm, customizable | Optional 800mm width, 950-1200mm depth |
| Material | Seven-fold profile main frame, 2.0mm SPCC cold-rolled steel plate | High structural strength, load capacity ≥1000kg |
| Mesh Door | Opening rate ≥75% | Optimize airflow path and reduce wind resistance |
| Protection Grade | IP20 | Dustproof, ensure equipment safety |
| Color | Black/Grey (customizable) | Electrostatic spraying, anti-corrosion and durable |
| Cabinet Combination | Unlimited cabinet combination supported | Modular combination for variable length requirements |
3. Cooling System Parameters
| Parameter Item | Technical Index | Remark |
|---|---|---|
| In-row Air Conditioner Cooling Capacity | 10-30kW (standard), N+1 redundancy supported | Adapt to variable load requirements |
| Temperature Control Accuracy | 18-22℃ (adjustable), temperature difference ≤±1℃ | Comply with ANSI/TIA-942 standard |
| Humidity Control Accuracy | 45%-60%RH, fluctuation ≤±3% | Prevent equipment condensation and ensure stable operation |
| Air Supply Mode | Horizontal air supply, proximal cooling | Short cold air delivery distance and high efficiency |
| Fan Type | EC variable frequency fan | Energy saving ≥30%, low noise ≤60dB |
| Communication Interface | RS485, Modbus protocol supported | Access to intelligent management platform for remote monitoring |
4. Monitoring & Management System Parameters
| Parameter Item | Technical Index | Remark |
|---|---|---|
| Monitoring Parameters | Temperature, humidity, smoke, access status, air conditioner operating parameters | Full coverage of key environmental indicators |
| Temperature Measuring Range & Accuracy | -10℃~50℃, accuracy ±0.5℃ | Real-time monitoring of cold aisle temperature changes |
| Humidity Measuring Range & Accuracy | 20%-90%RH, accuracy ±2%RH | Prevent equipment failure caused by abnormal humidity |
| Alarm Mode | Sound & light alarm, SMS alarm, email alarm | Multi-channel reminder for timely abnormality handling |
| Management Platform | Web access supported, Chinese & English bilingual interface | Remote monitoring, historical data query and report generation |
| Data Storage | Historical data storage ≥1 year | Meet data analysis and audit requirements |

VII. Application Scope
1. Industry Applications
- Government Institutions: Regional government cloud computer rooms, sub-district office computer rooms, police station computer rooms
- Education Industry: Primary and secondary school campus computer rooms, university laboratory computer rooms, vocational college training centers
- Medical Industry: Hospital outpatient computer rooms, community health service center computer rooms, medical imaging centers
- Enterprise Users: Medium-sized enterprise headquarters IT computer rooms, branch computer rooms, R&D center test computer rooms
- Financial Industry: Bank outlet computer rooms, securities business department computer rooms, insurance branch computer rooms
- Energy Industry: Substation control rooms, new energy enterprise data acquisition computer rooms
- Internet Industry: Edge computing nodes, small IDC computer rooms, e-commerce enterprise data centers
2. Applicable Scenario Characteristics
- Number of cabinets: 6-12 units (standard configuration), expandable to 24 units
- Single cabinet power density: ≤5kW (suitable for ordinary servers and storage devices)
- Computer room space: Area ≤100㎡, clear height ≥2.8m
- Deployment cycle: Fast online launch (≤1 week), supporting later capacity expansion
- Energy efficiency requirement: PUE ≤1.5, compliant with green data center standards

VIII. Core Product Advantages
1. High Energy Saving & Low PUE
- Significant PUE reduction: Complete cold and hot air isolation improves cooling efficiency by 30%, reducing PUE to 1.3-1.5 with annual power savings of tens of thousands of yuan
- Improved cold air utilization: Enclosed design increases cold air utilization rate from traditional 60% to over 90%, reducing cooling equipment configuration demand
- Intelligent frequency conversion control: EC fans of in-row air conditioners automatically adjust speed according to load to further reduce energy consumption
2. Rapid Deployment & Flexible Expansion
- Modular design: All components are factory prefabricated, only on-site splicing required, shortening deployment cycle from weeks to hours
- Plug-and-play: Pre-integrated power supply, cooling and monitoring systems, ready for operation after power-on
- Seamless expansion: Support on-demand capacity expansion from 3 to 24 cabinets to protect initial investment
3. Precise Temperature Control & High Reliability
- Zero local hotspots: Enclosed cold aisle + proximal cooling ensures uniform aisle temperature with deviation ≤±1℃, eliminating hotspots (≤24℃)
- Redundant configuration: Support N+1 cooling and UPS redundancy to ensure continuous system operation with MTBF ≥100,000 hours
- Intelligent monitoring: Real-time environmental parameter monitoring and automatic abnormality alarm reduce downtime risk by 70% with early fault warning
4. Low Cost & Easy Maintenance
- Low initial investment: Save over 30% of space and equipment cost compared with double-row cold aisle systems
- Low operating cost: 30%+ energy saving, 50% reduction in maintenance labor cost, and extended equipment service life
- Convenient maintenance: Quick-opening aisle end doors, front and rear cabinet maintainability without entering the cold aisle
- Noise reduction: Enclosed structure effectively reduces equipment operating noise and improves on-site working environment
5. Safety & Compliance
- Fire safety: All materials adopt Class A fireproof grade, equipped with fire linkage devices, complying with GB 50174-2017 standards
- Personnel safety: Equipped with emergency lighting and emergency passage design to ensure maintenance personnel safety
- Environmental compliance: High energy efficiency conforms to national green data center policies and supports enterprise carbon emission reduction goals

IX. Bid Winning Core Parameters
1. Core Technical Requirements
- The system shall adopt single-row linear cabinet layout and fully enclosed cold aisle design with cold air leakage rate <5%, complying with GB 50174 Data Center Design Specification
- Standard cold aisle width is 1200mm, customizable 800-1800mm, adapting to 1-2 anti-static floor widths
- Cabinets shall adopt seven-fold profile main frame and 2.0mm SPCC cold-rolled steel plate, with mesh door opening rate ≥75% and load capacity ≥1000kg
- The cooling system adopts in-row precision air conditioners for proximal cooling, with temperature control range 18-22℃ (temperature difference ≤±1℃) and humidity control range 45%-60%RH
- System PUE ≤1.5, cold air utilization rate ≥90%, energy saving efficiency ≥30% compared with traditional computer rooms
- The monitoring system shall support real-time monitoring of temperature, humidity, smoke, access and air conditioner parameters, with multi-channel alarm functions (sound & light, SMS, email)
2. Key Component Technical Standards
| Component Name | Bid Winning Requirements | Testing Standard |
|---|---|---|
| Cold Aisle End Door | ≥8mm frameless explosion-proof tempered glass, aluminum alloy frame, light transmittance ≥90% | GB 15763.2-2005 |
| Cold Aisle Top Plate | Composite metal plate, Class A fire rating, load capacity ≥100kg/㎡ | GB 8624-2012 |
| Server Cabinet | 2000×600×1100mm, 2.0mm SPCC cold-rolled steel plate, IP20 protection grade | GB 2887-2011 |
| In-Row Air Conditioner | Cooling capacity ≥20kW, EC variable frequency fan, noise ≤60dB, Modbus protocol supported | GB/T 19413-2010 |
| UPS Module | Power ≥20kW, modular hot-swappable design, efficiency ≥95% | GB/T 14715-2017 |
| Monitoring Platform | Web access supported, historical data storage ≥1 year, Chinese & English bilingual interface | GB/T 2887-2011 |
3. Construction & Acceptance Standards
- Adopt modular splicing installation without welding, installation cycle ≤3 days for 12-cabinet configuration
- Complete air tightness test after cold aisle sealing, cold air leakage rate <5% to meet design requirements
- Conduct temperature field test after stable system operation, no local hotspots (≤24℃) and temperature difference ≤±1℃ in the cold aisle
- Provide complete test reports including PUE value, cold air utilization rate and temperature uniformity during acceptance
- Provide ≥3-year warranty, 7×24-hour technical support, fault response time ≤4 hours, problem solving time ≤24 hours
X. Customized Solution Packages
1. Standard 6-Cabinet Solution
Applicable Scenarios: Small enterprise computer rooms, branch computer rooms, campus computer rooms
Core Configuration:
- Cold aisle containment system: 6m length, 1200mm width, including 2 sets of end doors, 6 top plates, 5 partition columns
- Cabinet system: 6 sets of standard server cabinets (2000×600×1100mm), equipped with blanking panels and cable organizers
- Cooling system: 1 set of 20kW in-row precision air conditioner, 2 temperature sensors
- Power supply & distribution system: 1 precision distribution cabinet, 1+1 sets of 20kW UPS modules, 6 PDUs, 1 battery pack set
- Monitoring system: 1 set of intelligent management platform, 2 temperature & humidity sensors, 1 smoke detector, 1 access control system
- Auxiliary system: 2 emergency lights, 1 fire linkage device, 1 ventilation system set
Features: Rapid deployment (≤1 day), PUE ≤1.5, suitable for load ≤25kW scenarios
2. Extended 12-Cabinet Solution
Applicable Scenarios: Medium-sized enterprise computer rooms, government department computer rooms, hospital computer rooms
Core Configuration:
- Cold aisle containment system: 12m length, 1200mm width, including 2 sets of end doors, 12 top plates, 11 partition columns
- Cabinet system: 12 sets of standard server cabinets, equipped with blanking panels and cable organizers
- Cooling system: 2 sets of 20kW in-row precision air conditioners (N+1 redundancy), 4 temperature sensors
- Power supply & distribution system: 1 precision distribution cabinet, 2+1 sets of 20kW UPS modules, 12 PDUs, 2 battery pack sets
- Monitoring system: 1 set of intelligent management platform, 4 temperature & humidity sensors, 2 smoke detectors, 1 access control system
- Auxiliary system: 4 emergency lights, 1 fire linkage device, 1 ventilation system set
Features: High reliability, PUE ≤1.4, suitable for load ≤50kW scenarios, support later expansion to 24 cabinets
3. Customized Special Solutions
- High-Density Configuration: Support single cabinet power density 5-8kW, equipped with high-efficiency in-row air conditioners and reinforced cold aisle sealing
- Waterless Computer Room Configuration: Adopt air-cooled in-row air conditioners without water pipes, suitable for anhydrous environments
- Low-Noise Configuration: Adopt low-noise in-row air conditioners (≤55dB), suitable for computer rooms near office areas
- Long-Delay Power Supply Configuration: UPS battery pack supports 4-8 hours power delay to ensure continuous operation of key businesses

XI. Typical Application Cases
Case 1: Campus Computer Room Renovation Project of Municipal Education Bureau
Project Background: The original open-layout computer room suffered from severe local hotspots (32℃) and high energy consumption with PUE up to 2.1.
Solution: Adopt KITOZER 6-cabinet standard single-row cold aisle system, equipped with 20kW in-row air conditioner and 1+1 UPS redundancy configuration.
Implementation Effect:
- Cold aisle temperature stabilized at 20±1℃ with zero local hotspots
- PUE reduced to 1.4, annual power saving of about 30,000 CNY
- Completed deployment within 1 day without affecting teaching operations
- Intelligent remote monitoring reduces maintenance manpower by 50%
Case 2: New Outpatient Computer Room Project of Grade A Hospital
Project Background: The new outpatient building required a IT computer room with rapid deployment, high reliability and low energy consumption.
Solution: Adopt KITOZER 12-cabinet extended single-row cold aisle system with 2 sets of 20kW N+1 redundant in-row air conditioners.
Implementation Effect:
- Zero system failure record after 1-year stable operation, ensuring continuous operation of medical systems
- PUE reaches 1.35, meeting green hospital construction standards
- Enclosed cold aisle reduces computer room noise and improves working environment
- Support later expansion to 24 cabinets to meet growing business demands
Case 3: Enterprise Branch Standardized Computer Room Project
Project Background: The enterprise needed to build standardized computer rooms for multiple national branches with rapid delivery and low cost.
Solution: Adopt KITOZER 6-cabinet standard modular single-row cold aisle system with factory prefabricated components.
Implementation Effect:
- Unified national standard, single-site deployment cycle ≤3 days, construction cost reduced by 30%
- Centralized remote management reduces on-site IT maintenance staffing
- All site PUE ≤1.5, achieving group energy saving and emission reduction goals
- Rapidly respond to business expansion and support on-demand capacity expansion

XII. SEO Keywords & Tags
Core Search Keywords
Modular cold and hot aisle, single-row cold aisle, data center cold aisle, computer room cold and hot aisle, KITOZER cold aisle, small and medium-sized data center solution, cold aisle containment system, in-row air conditioner cooling, low PUE computer room solution, rapid deployment computer room system
SEO Optimization Description
1. Core keyword density: The core keyword “modular single-row cold aisle containment system” appears more than 10 times throughout the text, and related keywords such as “cold aisle containment system” and “in-row air conditioner” appear more than 5 times.
2. Title optimization: The main title contains core keywords, and subtitles clarify product features and advantages.
3. Content structure: Adopt clear H1-H3 title hierarchy, with tables and lists to enhance readability.
4. Technical parameters: Detailed technical indicators improve professionalism and search relevance.
5. Application cases: Real scenario cases enhance user trust and content credibility.
Product Tags
#ModularColdAisle #SingleRowColdAisle #DataCenter #ComputerRoomConstruction #ColdAisleContainment #InRowAirConditioner #LowPUE #KITOZER #RapidDeployment #IntelligentMonitoring