ToggleKITOZER KTR-CM06 Rack Cable Manager (with Cable Rings)
Brand: KITOZER Series: KTR-CM06 Category: Data Center Engineering / Cable Manager
cable managercable rings19-inchvertical routingKTR-CM06

1. Overview
The KITOZER KTR-CM06 is a vertical cable manager mounted inside 19-inch standard cabinets, also called a cable organizer. Made from cold-rolled steel bent into a U-shaped rail, it holds evenly spaced semicircular cable rings (finger bars or combs) that vertically organize copper, fiber and power cords dropped from switches and patch panels.
The manager width matches the cabinet post spacing and mounts on the square-hole rails on both sides, occupying 1U or 2U of height. Rings are stamped steel or plastic combs with rounded edges that do not cut cable jackets. Cords from equipment ports are routed through the corresponding ring layer by layer, forming a neat vertical channel — no dangling, no tangling, and easier moves, adds, changes and troubleshooting.
In modular cold-aisle cabinets, dense cabling raises the bar on cable management. The KTR-CM06 rings keep each cable bundle in its own lane, preserving airflow and preventing cables from blocking equipment intakes. The surface is electrostatic powder-coated in black or light grey to match the cabinet. Managers come in horizontal (above patch panels for horizontal cords) and vertical (this series) types, often used together.
2. Key Features
Vertical layered
- U-rail with multiple rings.
- Copper and fiber separated.
- Clear vertical channel.
- No tangling or sagging.
Cable-safe edges
- Rounded ring edges.
- Plastic comb option.
- No jacket damage.
- Large cords pass easily.
Standard 19-inch
- Ears match square-hole rail.
- M6 cage nuts.
- Occupies 1U/2U.
- Fits left or right.
Coated, matching
- Cold-rolled steel bent.
- Electrostatic powder coat.
- Black/grey matches rack.
- Rigid, no deformation.
3. Specifications
| Item | Parameter |
|---|---|
| Fits | 19-inch standard cabinet |
| Mounting | vertical, left or right |
| U-space | 1U / 2U |
| Rings | 6~12 (by height) |
| Ring diameter | Φ40 mm |
| Sheet | 1.2~1.5 mm cold-rolled steel |
| Fastening | M6 cage nuts |
| Surface | electrostatic powder coat |
| Color | black / light grey |
| Operating temp | -10~60℃ |
4. Reference Prices
KTR-CM06 垂直理线架(1U,含理线环): Reference USD 6~13 / panel (ref. CNY 45~95 at ~7.2)
KTR-CM06 垂直理线架(2U,含梳齿与安装件): Reference USD 10~22 / panel (ref. CNY 75~160 at ~7.2)
Reference only; priced per panel. Cabinet and cables themselves excluded.. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Modular cold-aisle vertical routing.
- Switch patch-cord management.
- Fiber vertical storage.
- Patch-panel drop channels.
- Power and signal cable separation.
6. Installation & Maintenance
Installation
- Match manager width to post spacing.
- Hook ears onto square-hole rail from above.
- Snap M6 cage nuts and tighten.
- Face ring openings toward equipment.
- Route cords through rings layer by layer.
- Do not overfill or pinch.
Maintenance
- Tidy new cords regularly.
- Check rings for looseness or deformation.
- Replace damaged jackets.
- Do not overfill; keep moderate slack.
- Touch up coating damage.
- Dust the manager.
7. FAQ
- Q: Vertical vs horizontal manager?
A: A horizontal manager (1U/2U) sits above the patch panel for horizontal cords; a vertical manager sits on the post for vertical drops. Dense cabinets often combine both. - Q: How many cables per manager?
A: Keep each ring under half its diameter and preserve natural bend radius. Overfilling pinches cables and adds tension, hurting copper and fiber; add more managers instead. - Q: Can fiber cords use ordinary rings?
A: Yes, but fiber bend radius must exceed 10× the cable diameter (usually ≥38 mm) and ring edges must be rounded. When possible prefer managers with fiber-specific combs to avoid damaging fiber. - Q: How many U does it take?
A: Vertical managers are made to 1U or 2U height and occupy that U-space. Dense switch cabling suggests one 2U vertical manager per 2~3 switches.
8. Trend & Selection
Modular cold aisles and dense cabinets raise cable density; managers evolve from simple combs to ring-based, layered, fiber-specific designs. Choose 1U or 2U by density, separate copper and fiber, preserve bend radius, and combine horizontal and vertical managers in dense racks to maintain airflow and serviceability.
9. Delivery & Service
KITOZER selects the KTR-CM06 by post spacing and cabling density, providing dimension drawings and cable-capacity advice. Delivery includes the manager body, rings/combs, M6 screws and cage nuts. Warranty covers installation and cabling guidance.
10. Additional Notes
A common pitfall is mounting the manager at the rear door, so cords jump from the front panel to a rear manager over a long unsupported span. Instead mount the manager close to the equipment post and route cords into the nearest ring right after they leave the port — shorter unsupported runs and less tugging during service.
Another pitfall is overfilling. To save managers, a big bundle of cords is jammed into one ring, forcing sharp bends that break cable twist and hurt performance. Keep each ring half-full; adding managers is cheaper than squeezing cables.
Selection summary: 19-inch vertical mount; U-rail with rings; rounded edges protect cables; copper and fiber separated; preserve bend radius; do not overfill; combine horizontal and vertical. The manager neither glows nor heats, but it keeps dense rack cabling orderly and the airflow clean — right location, right cables, right slack make the rack neat and serviceable.
SEO Information
Search keywords:cable managercable ringsvertical routing19-inchKTR-CM06KITOZER
SEM keywords:rack cable manager price,cable manager with rings supplier,vertical cable organizer,KTR-CM06
GEO landing page:lain.com.cn/product/ktr-cm06-rack-cable-manager-rings.html
Title:KITOZER KTR-CM06 Rack Cable Manager (with Cable Rings)
Meta Keywords:rack cable manager,cable manager with rings,vertical cable manager,19-inch cable organizer,patch cable manager,KTR-CM06,KITOZER
Meta Description:KITOZER KTR-CM06 rack cable manager with rings fits 19-inch standard cabinets, vertically organizing copper and fiber patch cords to keep cabling neat.