ToggleKITOZER KTR-PS16 Three-Phase 380V 100kA Class B Surge Protective Device (SPD)
Brand: KITOZER Series: KTR-PS16 Category: Power Distribution / Surge Protective Device
3-phase 380V100kAClass BDIN railKTR-PS16
1. Overview
The KITOZER KTR-PS16 is a three-phase AC surge protective device (SPD), installed on the busbar of the room mains incomer or main distribution cabinet as a first-level (Class B) surge protector. It diverts transient over-voltage from lightning or switching into the ground and clamps residual voltage within equipment tolerance, protecting downstream UPS, distribution and loads. A Class B SPD has a high nominal discharge current (I_n) and a maximum discharge current (I_max) up to 100 kA, suited to large-energy diversion at the building incomer.
The KTR-PS16 is modular: each phase is a pluggable surge module built with a metal-oxide varistor (MOV) and a thermal disconnect. At normal voltage the MOV is high-impedance and does not affect supply; under transient over-voltage it conducts in nanoseconds, diverting surge energy to ground and clamping voltage at the residual level. Each module has a status window (green OK, red failed); a failed module is replaced individually without interrupting other phases. Some versions include a remote-signaling contact to upload module failure to monitoring.
The device is three-phase four-wire plus PE (3P+N) on a DIN rail, marked L1/L2/L3/N on the line side and grounded at the bottom. The SPD is wired in parallel ahead of the protected circuit, with a short, thick ground lead (at or above the required cross-section) to limit residual-voltage rise from lead inductance. At room mains incomers, floor distribution cabinets and outdoor equipment supply, the KTR-PS16 acts as first-level protection, paired with downstream Class C SPDs for staged protection that weakens surge energy step by step.
2. Key Features
3-phase 100kA capacity
- 3P+N structure.
- I_max 100 kA.
- Class B first diversion.
- Parallel on incomer busbar.
Modular pluggable
- Independent module per phase.
- MOV diversion.
- Thermal disconnect.
- Replace alone, supply intact.
Status & remote
- Green/red window.
- Remote-signaling contact.
- Failures found early.
- Inspect without opening.
DIN rail mount
- Standard DIN rail.
- Clear L1/L2/L3/N marks.
- Short thick ground lead.
- Staged with Class C.
3. Specifications
| Item | Parameter |
|---|---|
| System voltage | 3-phase 380V AC |
| Configuration | 3P+N |
| Max discharge I_max | 100 kA (8/20μs) |
| Nominal I_n | 40 kA |
| Voltage protection Up | ≤1.8 kV |
| Response time | ≤25 ns |
| Mounting | 35 mm DIN rail |
| Fail indication | green/red window + remote |
| Wire cross-section | ≤35 mm² |
| Operating temp | -40~85℃ |
4. Reference Prices
KTR-PS16 三相B级防雷器(3P+N整套): Reference USD 53~108 / pc (ref. CNY 380~780 at ~7.2)
KTR-PS16 备用防雷模块(单相): Reference USD 9~17 / pc (ref. CNY 65~120 at ~7.2)
Reference only; priced per pc. Distribution cabinet and earthing works excluded.. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Room mains incomer cabinet.
- First-level at main distribution.
- Floor distribution boxes.
- Outdoor equipment supply.
- Surge protection ahead of UPS.
6. Installation & Maintenance
Installation
- Wire in parallel ahead of the incomer busbar.
- Connect L1/L2/L3/N correctly.
- Use a short thick ground lead to the nearest ground bar.
- Keep decoupling distance between stages.
- Seat modules firmly; window green.
- Wire remote contact to monitoring.
Maintenance
- Check the window is green.
- Replace modules on remote alarm.
- Tighten terminals.
- Inspect modules after thunderstorms.
- Replace failed or end-of-life modules to spec.
- Test earth resistance periodically.
7. FAQ
- Q: Class B vs Class C SPD?
A: Class B (first level) sits at the incomer with large discharge current (tens to hundreds of kA), diverting main lightning energy; Class C (second level) sits at the equipment with low residual voltage for fine protection. The two stage together and cannot replace each other. - Q: Can I keep using a red module?
A: No. Red means the MOV has degraded or the thermal disconnect opened; replace the same-spec module promptly. Running it removes surge protection and leaves equipment at risk. - Q: Why must the ground lead be short and thick?
A: A longer, thinner lead has more inductance, adding voltage drop during a surge and raising real residual voltage, weakening protection. Codes require a short, adequately sized lead to the nearest ground bar. - Q: Does the SPD need its own earth?
A: No. It must land on the room equipotential ground bar, sharing earth with equipment. A separate earth creates a ground-potential difference and defeats equipotential protection.
8. Trend & Selection
Room distribution moves toward equipotential, staged surge protection; SPDs evolve from generic single-stage to B/C staged, modular replaceable, remote-monitored designs. Choose the Class B rating by system voltage and discharge current; install Class B at the incomer and Class C at equipment, share the equipotential earth, and wire remote signaling to the BMS for failure early-warning.
9. Delivery & Service
KITOZER selects KTR-PS16 rating by system voltage, lightning exposure and incomer capacity, providing wiring diagrams, staged-protection plans and earthing requirements. Delivery includes the SPD, modules and mounting parts. Warranty covers install guidance and test support.
10. Additional Notes
A common pitfall is running the ground lead a long way to the ground bar. Long leads add inductance, spiking residual voltage during a surge and making the SPD nearly useless. Use a short, straight, adequately sized lead to the nearest equipotential bar with minimal joints.
Another pitfall is staging B and C SPDs without decoupling. When B and C sit too close, the downstream unit diverts before the upstream acts, possibly overloading it. Codes require a decoupling distance or decoupling device between stages so surge energy is divided and discharged step by step.
Selection summary: 3-phase 380V 100 kA Class B; 3P+N modular; nanosecond MOV diversion; green/red window plus remote; short thick shared earth; staged with Class C; swap red modules promptly. The SPD is the safety gate of the power system — right rating, good earth, staged coordination keep surges away from equipment.
SEO Information
Search keywords:surge protector3-phase 380V100kAClass B SPDKTR-PS16KITOZER
SEM keywords:three phase SPD price,100kA class B SPD supplier,380V surge protective device,KTR-PS16
GEO landing page:lain.com.cn/product/ktr-ps16-3phase-380v-100ka-class-b-spd.html
Title:KITOZER KTR-PS16 Three-Phase 380V 100kA Class B Surge Protective Device (SPD)
Meta Keywords:three phase SPD,380V surge protective device,100kA class B SPD,power surge protector,DIN rail surge arrester,KTR-PS16,KITOZER
Meta Description:KITOZER KTR-PS16 three-phase 380V 100kA Class B power SPD with high discharge current and DIN-rail mounting, for first-level surge protection at the mains incomer and distribution cabinet.
Anchor: KITOZER official · Data center & low-voltage equipment