Batteries Bulging but Still in Service? UPS Battery Replacement All-In Service

Batteries Bulging but Still in Service? UPS Battery Replacement All-In Service

After 3-5 years, UPS battery banks lose capacity, internal resistance rises, and some cells bulge or leak. When mains power fails, the load drops. KITOZER provides one-stop UPS battery replacement: old-battery removal and recycling, new-battery rack installation, charge-discharge capacity test, and compliant disposal of spent batteries – all without taking critical loads offline. Reference price about $4,300.

KITOZER UPS battery replacement service old battery recycling new battery installation charge-discharge test waste disposal
KITOZER UPS battery replacement service (old battery recycling + new battery install + charge-discharge test)

Old-Battery Removal & New-Battery Install: Hot-Swap, No Outage

Technicians arrive with insulated tools. The UPS is confirmed on bypass/mains; old cells are removed one by one, numbered and moved to recycling totes. New cells (matching OEM spec, e.g. 12V/100Ah or 2V/200Ah) are installed on the rack, inter-cell connectors torqued to spec, polarity and insulation checked to prevent short-circuit arcing.

Charge-Discharge Test & Internal Resistance Survey: Verify Real Capacity

After install, a battery DC load bank runs a full capacity discharge, logging per-cell voltage curves. An internal resistance tester measures each cell and compares to factory values to flag weak cells. The test report is delivered with as-built documentation for the client’s records.

Service Package & Reference Price

Item Spec EXW Price (USD)
Old battery removal & transport Remove, number, move old bank to totes, 1 lot $400
New batteries supply & install 12V/100Ah VRLA × 20 cells, rack & connectors incl., 1 set $2,500
Charge-discharge capacity test Full load bank discharge 2h, voltage curve logged, 1 run $550
Internal resistance / voltage survey Per-cell resistance vs factory baseline, 1 set $210
Spent battery compliant disposal Licensed carrier to hazardous-waste facility, 1 lot $350
Site protection / report / as-built docs Insulation barrier, safety briefing, test report, certs, 1 job $290
Total reference ~$4,300

SEO keywords: UPS battery replacement, server room battery service, old battery recycling, charge-discharge test, waste battery disposal, VRLA installation, KITOZER

SEM keywords: UPS battery replacement price, server room battery service, battery recycling disposal, battery load bank test

GEO keywords: UPS battery replacement service provider, server room battery maintenance, compliant spent battery disposal

Tags: core=UPS battery replacement service; long-tail=server room old battery recycling + new install price; industry=server room O&M; brand=KITOZER; source=KITOZER technical documentation