The KITOZER Modular Cold & Hot Aisle System (Aisle Fire Linkage Accessories) is an integrated intelligent airflow management and fire safety solution designed exclusively for critical infrastructures such as data centers and server rooms. By physically isolating cold and hot airflows combined with intelligent fire linkage control, the system achieves dual goals: maximizing cooling efficiency and optimizing fire safety. It provides a stable, secure and high-efficiency operating environment for IT equipment, reduces energy costs, and improves the overall PUE of the data center.
Core Values:
• 100% physical isolation of cold and hot airflows to eliminate air short-circuiting, raising cooling utilization to over 90%
• Seamless linkage with fire protection systems for automatic response in case of fire, safeguarding personnel and equipment
• Modular design enabling fast deployment and flexible expansion to fit data centers of all sizes
• Intelligent monitoring and remote management for real-time aisle status visibility and improved O&M efficiency
1.2 System Working Principle
The system adopts a dual mechanism of cold‑hot separation + intelligent linkage:
- Airflow Management: Racks are arranged face‑to‑face to form cold aisles and back‑to‑back to form hot aisles. Enclosed spaces are constructed with ceiling panels, side panels and end doors. Cold air is delivered into the cold aisle via raised floors or in‑row air conditioners, passes through rack perforated doors to absorb heat from IT equipment, and is exhausted into hot aisles for recycling by air conditioners, forming a high‑efficiency airflow cycle.
- Fire Linkage: When fire detectors (smoke/heat) detect anomalies, signals are sent to the fire linkage controller, which automatically triggers the following actions: ◦ Cut off non‑essential power supplies in the aisle ◦ Open fire‑fighting skylights (automatically open to 290° within 10 seconds) to ensure smooth entry of fire‑fighting gas ◦ Shut down ventilation equipment to prevent fire spread ◦ Activate audible and visual alarms to notify evacuation ◦ Link with gas fire suppression systems for precise agent discharge

II. System Composition
The KITOZER Modular Cold & Hot Aisle System (Aisle Fire Linkage Accessories) consists of the following core components:
| System Module | Main Components | Function Description |
|---|---|---|
| Basic Frame System | Aluminum alloy/steel aisle frames, columns, beams | Supports aisle structure; provides mounting base; load capacity ≥250kg/m² |
| Airflow Containment System | Aisle ceiling panels, side panels, end doors (manual/auto sliding) | Physically isolates cold/hot air; air leakage rate ≤2% |
| Fire Linkage Accessories | Fire‑resistant transparent skylights (UL94 V0 polycarbonate), magnetic locks, linkage controllers | Automatically open skylights in fire events; cooperate with gas fire suppression systems |
| Intelligent Monitoring System | Temperature & humidity sensors, smoke detectors, door contacts, audible‑visual alarms | Real‑time aisle environment monitoring; automatic alarm for anomalies |
| Control System | Aisle control module, fire linkage interface, remote management software | Local and remote control; seamless connection with fire systems |
| Auxiliary System | LED lighting, emergency lighting, cable management trays, grounding devices | Provides illumination, cable management and safety grounding |
III. System Classification
3.1 By Aisle Type
| Category | Features | Applicable Scenarios |
|---|---|---|
| Cold Aisle Containment System | Encloses cold aisle for centralized cold air management; high cooling utilization | Standard data centers, high‑density rooms pursuing PUE optimization |
| Hot Aisle Containment System | Encloses hot aisle for centralized hot air exhaust; improves AC efficiency | Legacy room retrofits, side‑supply AC scenarios |
| Dual Containment System (Cold + Hot) | Encloses both aisles for maximum airflow efficiency | Ultra‑high‑density data centers, large cloud computing centers |
3.2 By Fire Linkage Mode
| Category | Linkage Mechanism | Trigger Condition | Response Time |
|---|---|---|---|
| Electric Fire Linkage System | DC24V signal trigger; magnetic lock de‑energizes; skylight opens automatically | Fire alarm signal, temperature ≥58°C | ≤10 seconds |
| Thermal Fuse Linkage System | FuseLink automatic melting; skylight opens by gravity | Temperature ≥58°C (independent of power) | ≤5 seconds |
| Dual‑Trigger Fire Linkage System | Electric + thermal fuse dual trigger for extreme reliability | Fire signal OR over‑temperature | ≤3 seconds |
3.3 By Deployment Scale
| Category | Aisle Length | Number of Racks | Applicable Scenarios |
|---|---|---|---|
| Small Aisle System | ≤4m | 2–4 racks | Edge computing nodes, small server rooms |
| Medium Aisle System | 4–10m | 4–10 racks | Enterprise data centers, branch server rooms |
| Large Aisle System | >10m | >10 racks | Cloud computing centers, hyperscale data centers |

IV. System Configuration List (Brand: KITOZER)
4.1 Basic Frame Components
| Product Name | Model | Specifications | Quantity | Notes |
|---|---|---|---|---|
| Aisle Column | KT‑ZL‑120 | Height 2200/2400/2600mm; aluminum alloy | Calculated by aisle length | Load ≥500kg per column |
| Aisle Beam | KT‑HL‑80 | Length 600/800/1000mm; steel with powder coating | Calculated by aisle length | Fits standard rack spacing |
| Connecting Bracket | KT‑JJ‑01 | Aluminum alloy with matching bolts | By frame quantity | Reinforces frame connection |
4.2 Airflow Containment Components
| Product Name | Model | Specifications | Quantity | Notes |
|---|---|---|---|---|
| Aisle Ceiling Panel | KT‑DB‑30 | 3mm polycarbonate sheet, UL94 V0 | Calculated by aisle area | Light transmittance ≥85%; UV‑resistant |
| Manual Sliding End Door | KT‑DM‑01 | 1200×2200mm; tempered glass + aluminum frame | 2 doors/aisle | Threshold‑free for easy equipment access |
| Automatic Sliding End Door | KT‑DM‑02 | 1200×2200mm; tempered glass + aluminum frame; motor‑driven | 2 doors/aisle | Card/induction opening; anti‑pinch function |
| Aisle Side Panel | KT‑CB‑01 | Aluminum alloy; height 2200mm | Calculated by aisle length | Removable for maintenance |
4.3 Fire Linkage Accessories (Core Components)
| Product Name | Model | Specifications | Quantity | Notes |
|---|---|---|---|---|
| Fire‑Resistant Transparent Skylight | KT‑XC‑30 | 3mm fire‑retardant polycarbonate, UL94 V0 | Calculated by aisle area | Opens to 290° within 10s; load ≥250kg/m² |
| Magnetic Lock | KT‑CL‑24 | DC24V; holding force ≥200kg | 1 per skylight | Fire linkage control; power‑off release |
| Linkage Controller | KT‑LD‑01 | 8‑channel I/O; DC24V power supply | 1 per aisle | Connects to fire system; dry contact support |
| Smoke Detector | KT‑YW‑01 | Photoelectric; sensitivity 0.05–0.15%obs/m | 1 per 10㎡ | Links with linkage controller |
| Heat Detector | KT‑WG‑01 | Temp range ‑10~80°C; response at 58°C | 1 per 10㎡ | Dual protection against false alarms |
| Audible‑Visual Alarm | KT‑SG‑01 | Volume ≥85dB; flash frequency 1–2Hz | 1 per aisle | Audible‑visual alert in fire event |
4.4 Intelligent Monitoring & Control System
| Product Name | Model | Specifications | Quantity | Notes |
|---|---|---|---|---|
| Aisle Control Module | KT‑KZ‑01 | Integrates temp/humidity monitoring, door status, skylight control | 1 per aisle | Local control and display |
| Fire Linkage Interface | KT‑JK‑01 | Standard RS485; Modbus protocol | 1 per aisle | Connects to third‑party fire systems |
| Remote Management Software | KT‑RM‑01 | Web access; real‑time monitoring and control | 1 set per project | Centralized multi‑aisle management; historical data query |
| Door Contact Switch | KT‑MC‑01 | Normally open/closed optional | 2 per aisle | Monitors end door status; anomaly alarm |
4.5 Auxiliary Components
| Product Name | Model | Specifications | Quantity | Notes |
|---|---|---|---|---|
| LED Lighting | KT‑ZM‑01 | DC24V; 13W; 90cm length | Calculated by aisle length | Energy‑saving; lifespan ≥50000 hours |
| Emergency Lighting | KT‑YJ‑01 | DC12V; built‑in battery; ≥90 minutes duration | 2 per aisle | Auto‑activates on power failure |
| Cable Management Tray | KT‑XL‑01 | Width 150mm; height 100mm | Calculated by aisle length | Separation of strong/weak current; supports 10G/400G |
| Grounding Device | KT‑JD‑01 | Copper; grounding resistance ≤1Ω | 4 per aisle | Ensures personnel and equipment safety |

V. System Schematic Diagrams
5.1 Airflow Cycle Diagram
[Raised Floor/In‑Row AC] → [Cold Air] → [Enclosed Cold Aisle] → [Rack Perforated Door] → [IT Equipment (Heat Absorption)] → [Hot Aisle] → [AC Return Air] → [AC Treatment] → [Cold Air]
5.2 Fire Linkage Control Diagram
[Fire Detector (Smoke/Heat)] → [Fire Controller] → [Linkage Signal] → [KT‑LD‑01 Linkage Controller] → [Action Execution]
├─ Cut non‑essential power
├─ Magnetic lock de‑energized → Fire skylight open (within 10s)
├─ Shut down ventilation equipment
├─ Activate audible‑visual alarm
└─ Link gas fire suppression system
5.3 System Topology Diagram
[Data Center Monitoring Center] ↔ [KT‑RM‑01 Remote Management Software] ↔ [KT‑LD‑01 Linkage Controller] ↔ [Sensors/Actuators]
↓
[Fire Control System] ↔ [Linkage Interface]
VI. Product Technical Specifications
6.1 Basic Frame Specifications
| Item | Technical Index | Test Standard |
|---|---|---|
| Frame Material | Aluminum alloy 6063‑T5 / high‑grade steel | GB/T 5237.1‑2017 |
| Surface Treatment | Anodizing / electrostatic powder coating | GB/T 18593‑2010 |
| Load Capacity | ≥250kg/m² | GB 28007‑2011 |
| Dimensional Accuracy | ±1mm | GB/T 1804‑2000 |
| Service Life | ≥15 years | Industry standard |
6.2 Airflow Containment Components Specifications
| Item | Technical Index | Test Standard |
|---|---|---|
| Air Leakage Rate | ≤2% | GB/T 1236‑2017 |
| Light Transmittance | ≥85% (ceiling/skylight) | GB/T 2680‑1994 |
| End Door Opening | Manual/auto sliding; opening force ≤50N | GB 28007‑2011 |
| Fire Rating | Ceiling/skylight UL94 V0 | UL 94 |
| Weather Resistance | UV‑resistant; lifespan ≥10 years | GB/T 16422.2‑2014 |
6.3 Fire Linkage Accessories Core Specifications
| Item | Technical Index | Test Standard |
|---|---|---|
| Skylight Opening Time | ≤10 seconds | GB 50116‑2013 |
| Skylight Opening Angle | 290° | Enterprise Standard |
| Magnetic Lock Voltage | DC24V; power ≤5W | GB/T 156‑2017 |
| Detector Response Time | ≤3 seconds | GB 4715‑2005 |
| Linkage Controller Interface | Dry contact; supports Modbus | GB/T 19582‑2008 |
| Operating Temperature | ‑10°C~+55°C | GB/T 2423.1‑2008 |
| Relative Humidity | 10%~90% (non‑condensing) | GB/T 2423.3‑2006 |
6.4 Intelligent Monitoring System Specifications
| Item | Technical Index | Test Standard |
|---|---|---|
| Temp Monitoring Range | ‑10°C~+80°C; accuracy ±0.5°C | GB/T 15479‑1995 |
| Humidity Monitoring Range | 0%~100%RH; accuracy ±3%RH | GB/T 15481‑2017 |
| Communication | RS485, Ethernet | GB/T 19582‑2008 |
| Data Refresh Rate | ≤1 second | Enterprise Standard |
| Alarm Mode | Audible‑visual; remote notification | GB 4717‑2005 |

VII. Application Scope
The KITOZER Modular Cold & Hot Aisle System (Aisle Fire Linkage Accessories) is suitable for:
7.1 Data Center Sector
• New large‑scale data centers and cloud computing centers
• Upgrade and retrofitting of existing data centers to improve cooling efficiency
• High‑density server rooms resolving local hotspots
• Edge computing nodes and small server rooms
• Financial, telecom, Internet and other mission‑critical data centers
7.2 Other Fields
• Telecommunication rooms and core equipment rooms
• Industrial automation control centers
• Medical imaging storage centers and scientific computing centers
• Military command centers and aerospace control centers
• Precision instrument laboratories sensitive to temperature

VIII. Product Advantages
8.1 Performance Advantages
- High Efficiency & Energy Saving: Isolates cold/hot airflows; cooling utilization >90%; reduces PUE below 1.3
- Precise Temperature Control: Aisle temperature stable at 18–22°C; zone temperature difference ≤1°C; no local hotspots (≤24°C)
- Fast Response: Fire linkage response ≤10 seconds for timely fire handling
- High Reliability: Key components use UL94 V0 fire‑retardant materials for extreme safety
8.2 Design Advantages
- Modular Design: Factory‑prefabricated components; on‑site fast assembly; deployment time reduced by 50%
- Flexible Expansion: Adjustable aisle length/width to fit various room sizes
- User‑Friendly: Threshold‑free doors for equipment access; removable side panels for easy maintenance
- Aesthetic Design: Transparent ceiling and glass doors enhance room appearance
8.3 Safety Advantages
- Dual Fire Protection: Electric + thermal fuse dual trigger; works even under power failure
- Personnel Safety: Emergency lighting, grounding, anti‑pinch doors for full protection
- Equipment Safety: Links with clean gas fire suppression; no damage to electronics
- Compliance: Meets GB 50174‑2017 Code for Design of Data Centers, GB 50016‑2014 Code of Design on Building Fire Protection and Prevention, etc.
8.4 O&M Advantages
- Intelligent Monitoring: Real‑time status; automatic anomaly alarm; remote management
- Easy Maintenance: Modular components for quick replacement; lower maintenance cost
- Historical Data Analysis: Logs temp, humidity, alarms for O&M optimization
- Remote Diagnosis: Remote fault troubleshooting reduces on‑site visits

IX. Bid‑Winning Parameters
9.1 Core Technical Parameters (Key Bid Points)
- Aisle frame: Aluminum alloy 6063‑T5; load ≥250kg/m²; compliant with GB/T 5237.1‑2017
- Fire skylight: 3mm fire‑retardant polycarbonate; UL94 V0; opens to 290° within 10s; compliant with UL 94
- Linkage response time: ≤10 seconds (including skylight opening, power cut, etc.)
- Air leakage rate: Overall aisle leakage ≤2%; compliant with GB/T 1236‑2017
- Temperature control accuracy: Aisle temp 18–22°C; zone difference ≤1°C; compliant with GB 50174‑2017
- Communication protocol: Supports Modbus; seamless third‑party monitoring integration; compliant with GB/T 19582‑2008
- Fire rating: Key components ≥ UL94 V0; compliant with UL 94
- Service life: Core components ≥10 years; meets industry standards
9.2 Commercial Parameters (Key Bid Points)
- Brand Qualification: KITOZER original factory production; provide brand authorization
- Certification: ISO9001 quality system, ISO14001 environmental certification required
- After‑Sales: ≥5‑year warranty; 24‑hour response; 48‑hour on‑site service
- References: ≥3 successful similar projects with user testimonials
- Technical Support: One‑stop service including design, installation guidance, commissioning and training
X. Customized Solutions
10.1 New Data Center Solution
- Demand Analysis: Design aisle layout based on room size, rack count and power density
- Solution Design: Cold aisle containment + fire linkage with in‑row AC for precise cooling
- Product Configuration: Full KITOZER modular aisle + fire linkage + intelligent monitoring
- Implementation Steps: ◦ Room planning and design ◦ Frame installation → Containment installation → Fire linkage installation → Monitoring installation ◦ System commissioning → Fire linkage test → User training
- Expected Outcome: PUE <1.3; cooling efficiency +30%; highest fire safety level
10.2 Existing Data Center Retrofit Solution
- Status Assessment: Analyze current airflow, cooling efficiency and fire system
- Solution Design: Partial cold aisle containment + fire linkage upgrade with minimal disruption
- Product Configuration: Aisle components matching existing racks + fire linkage + monitoring
- Implementation Steps: ◦ Zone‑by‑zone retrofit without business interruption ◦ Night construction to reduce impact ◦ Post‑retrofit testing for stable operation
- Expected Outcome: Cooling efficiency +20%; PUE reduced by 0.2–0.3; intelligent fire linkage
10.3 High‑Density Server Room Solution (≥8kW/rack)
- Demand Analysis: Resolve local hotspots for high‑power density rooms
- Solution Design: Dual cold/hot aisle containment + in‑row AC + intelligent fire linkage for maximum cooling
- Product Configuration: Reinforced frame + high‑efficiency containment + dual‑trigger fire linkage + high‑precision monitoring
- Implementation Steps: ◦ Pre‑simulation airflow analysis to optimize layout ◦ Custom component production for high‑density racks ◦ Installation and commissioning with focus on fire linkage
- Expected Outcome: Aisle temp stable at 20±1°C; no hotspots; fire response ≤5 seconds
XI. Application Cases
11.1 Case 1: Cloud Computing Center of a Large Internet Enterprise
• Project Profile: 1000 racks; 6kW/rack; new data center
• Solution: KITOZER cold aisle containment + fire linkage + intelligent monitoring with in‑row AC
• Results:
◦ PUE reduced from 1.8 to 1.28; annual electricity cost saving ~RMB 8 million
◦ Fire linkage response ≤8 seconds; passed fire inspection
◦ Stable operation for 2 years with zero failures
• User Comment: “The KITOZER system not only improves cooling efficiency but also provides all‑around fire safety for our data center.”
11.2 Case 2: Data Center Retrofit for a Financial Institution
• Project Profile: 500 racks; 4kW/rack; existing data center upgrade
• Solution: Partial cold aisle containment + fire linkage upgrade with minimal business impact
• Results:
◦ Cooling efficiency +25%; PUE from 1.6 to 1.35
◦ Zero business disruption during retrofit
◦ Fire system upgraded to intelligent linkage; meets latest codes
• User Comment: “The retrofit perfectly solves our pain points, improving efficiency and safety without business interruption.”
11.3 Case 3: Supercomputing Center of a Research Institute
• Project Profile: 200 racks; 10kW/rack; high‑density room
• Solution: Dual cold/hot aisle containment + dual‑trigger fire linkage + high‑precision monitoring
• Results:
◦ Aisle temp stable at 20±0.5°C; no local hotspots
◦ Fire linkage response ≤5 seconds; dual‑trigger ensures safety
◦ Cooling efficiency +35%; meets supercomputing requirements
• User Comment: “KITOZER provides a stable environment for our supercomputing equipment with full fire safety protection.”
XII. Search Keywords, SEO & Tags
12.1 Core Search Keywords
• Modular Cold & Hot Aisle
• Aisle Fire Linkage Accessories
• KITOZER Cold & Hot Aisle
• Data Center Cold Aisle
• Server Room Fire Linkage System
• Cold & Hot Aisle Containment System
• Intelligent Cold & Hot Aisle
• Data Center PUE Optimization
• Fire Skylight Linkage System
• Modular Server Room Solution
12.2 SEO Keywords
• Modular Cold & Hot Aisle System Solution
• Data Center Cold & Hot Aisle Fire Linkage Accessories
• KITOZER Cold Aisle Fire Linkage System
• New Data Center Cold Aisle Design
• Existing Data Center Cold Aisle Retrofit
• High‑Density Room Cold & Hot Aisle Solution
• Data Center Fire Linkage Control System
• Cold Aisle Containment Working Principle
• Cold & Hot Aisle System Technical Specifications
• Data Center Airflow Management Solution
12.3 Tags
#ModularColdHotAisle #FireLinkageAccessories #KITOZER #DataCenter #ServerRoom #ColdAisleContainment #HotAisleContainment #FireSkylight #IntelligentMonitoring #PUEOptimization #AirflowManagement #FireSafety #DataCenterSolution #ServerRoomRetrofit