I. System Overview

The KITOZER special ceiling system for computer rooms is an integrated ceiling solution independently developed by Guangdong Lai’an Intelligent Computer Room Equipment Co., Ltd. specifically for special environments including data centers, computer rooms and server rooms. Designed to meet stringent requirements of environmental control, equipment protection, safe operation and long-term stability for computer rooms, the system integrates high-strength structural design, dust-proof and noise reduction technology, fireproof & anti-static performance as well as convenient operation & maintenance features. It delivers a safe, reliable, energy-efficient and manageable overhead space solution and serves as one of the core components of modern computer room construction.

Different from conventional architectural suspended ceilings, the core value of the KITOZER dedicated computer room ceiling is to build a stable operating environment for precision electronic equipment. It resolves common drawbacks of traditional ceilings used in computer rooms such as falling dust, insufficient structural strength, poor heat dissipation and electromagnetic interference, while complying with special standards on fire rating, anti-static performance, load-bearing capacity and cleanliness for computer rooms.

II. System Composition

The KITOZER dedicated computer room ceiling system consists of the following core components to form a complete functional system:

表格

Structural LayerComponent NameFunction Description
Support Structure LayerMain Keel, Cross Keel, Suspension Rod, Connecting FittingsProvides stable support to bear loads of overhead equipment and pipelines; meets load requirements of static load ≥80kg/㎡ plus live load ≥70kg/㎡
Functional Panel LayerMicroporous Aluminum Alloy Panel, Anti-Static Panel, Ventilation Panel, Access PanelCore functional layer realizing dust prevention, sound absorption, ventilation and overhaul; flat surface for easy disassembly and assembly
Auxiliary Functional LayerSound-Absorbing Cotton, Dust Screen, Anti-Static Coating, Fire Retardant Treatment LayerOptimizes overall performance: improves sound absorption, blocks dust ingress, ensures fire safety and eliminates static hazards
Matching Component LayerRecessed Lamps, Air Outlet Adapters, Fire Protection Linkage Interfaces, Earthing DevicesIntegrates auxiliary facilities for lighting, air distribution, safety linkage and earthing protection
O&M Management LayerQuick-Access Overhaul Mechanism, Marking System, Load-Bearing Early Warning DeviceFacilitates system maintenance, enables rapid fault location and troubleshooting to guarantee long-term stable operation

III. System Classification

KITOZER dedicated computer room ceiling is categorized by multiple dimensions to fit various computer room scenarios.

3.1 Classification by Installation Mode

  1. Concealed Ceiling System
  • Features: Panels fully embedded inside keel frames with seamless flat finish for superior dust-proof performance
  • Application: Mid-to-high-end data centers, server rooms and core computer rooms with strict environmental requirements
  • Advantages: Dust accumulation resistance, easy cleaning, concealed pipelines & equipment and robust load capacity
  1. Exposed Grid Ceiling System
  • Features: Exposed keels with panels laid directly on keels; easy installation, adjustment and replacement
  • Application: Small & medium-sized computer rooms and renovation projects with limited construction budget
  • Advantages: Short construction period, low maintenance cost and quick panel replacement for frequent overhaul scenarios
  1. Modular Ceiling System
  • Features: Standardized modular design integrating lighting, ventilation and fire protection with plug-and-play functionality
  • Application: Large-scale data centers, cloud computing centers and modular computer room construction
  • Advantages: Factory prefabrication, fast on-site assembly, improved construction efficiency and convenient future capacity expansion

3.2 Classification by Functional Performance

表格

Ceiling TypeCore PerformanceApplicable Scenarios
Standard Computer Room CeilingBasic dustproof, fireproof and load-bearing properties for regular computer room environmentsEnterprise server rooms, network rooms and small-scale data centers
High-Ventilation Computer Room CeilingAdjustable ventilation rate from 20% to 40% matching air distribution of air conditioning systemsHigh-density server rooms and equipment rooms with high heat generation
Anti-Static Computer Room CeilingSurface resistance ranging from 10⁶Ω to 10⁹Ω to prevent static buildupElectronic component production workshops, precision instrument labs and microelectronics computer rooms
Shielded Computer Room CeilingElectromagnetic shielding efficiency ≥60dB to block electromagnetic interferenceConfidential computer rooms, military communication rooms and spaces housing EMI-sensitive equipment
Cleanroom-Grade Computer Room CeilingSealed dust-free structure for high-cleanliness environmentsMedical equipment computer rooms, semiconductor production workshops and bioinformatics centers

3.3 Classification by Raw Material

  1. Microporous Aluminum Alloy Ceiling (Recommended)
  • Material: 6063-T5 high-strength aluminum alloy complying with GB/T 3880-2006; high structural strength, corrosion resistance and lightweight
  • Available Thickness: 0.6mm / 0.8mm / 1.0mm for different load-bearing demands
  • Surface Treatment: Electrostatic powder coating in matte white with scratch and discoloration resistance
  1. Galvanized Steel Ceiling
  • Material: Hot-dip galvanized steel with outstanding anti-corrosion performance for high-humidity environments
  • Features: Superior structural strength and fire resistance for special computer rooms requiring high load-bearing and fire protection
  1. Composite Panel Ceiling
  • Material: Composite structures including aluminum alloy + mineral wool, aluminum alloy + calcium silicate board
  • Features: Combines merits of multiple materials to enhance sound absorption, thermal insulation and fire resistance for strictly controlled environments

IV. KITOZER System Configuration List

4.1 Standard Concealed Microporous Aluminum Alloy Ceiling Configuration List

表格

No.Product NameModel & Spec.BrandUnitRemarks
1Main KeelKT-ZL-50KITOZERM50mm width, galvanized steel, 1.2mm wall thickness, load capacity ≥120kg/㎡
2Cross KeelKT-FL-38KITOZERM38mm width, galvanized steel, 1.0mm wall thickness, 600mm installation spacing
3Suspension Rod AssemblyKT-DG-8KITOZERSetΦ8 full-threaded suspension rod with expansion bolt; single-set load ≥1kN
4Microporous Aluminum Alloy PanelKT-MP-6060KITOZER㎡600×600mm, 0.8mm thick 6063 aluminum alloy, 2mm aperture, 25% perforation rate
5Sound-Absorbing CottonKT-XY-25KITOZER㎡25mm thick centrifugal glass wool, density 48kg/m³, sound absorption coefficient ≥0.8
6Dust ScreenKT-FC-3KITOZER㎡3-layer high-density nylon screen with ≥95% filtration efficiency
7Recessed LED Lighting PanelKT-ZM-6060KITOZERPc600×600mm, LED source, brightness ≥500lux, 4000K color temperature
8Adjustable Ventilation PanelKT-TF-6060KITOZERPc600×600mm, 35% ventilation rate with adjustable louver design
9Reinforced Access PanelKT-JX-6060KITOZERPc600×600mm, reinforced structure, single-piece load ≥150kg for easy opening
10Anti-Static Earthing KitKT-JD-01KITOZERSetCopper earthing strip & terminals, surface resistance ≤10⁶Ω
11Special Connecting FittingKT-LJ-01KITOZERSetGalvanized anti-corrosion fittings for keel connection and panel fixation
12Edge Trim StripKT-SB-50KITOZERM50mm wide aluminum trim for various wall structures

4.2 Optional Configuration List

表格

No.Product NameModel & Spec.BrandUnitApplicable Scenario
1EMI Shield PanelKT-PB-6060KITOZER㎡≥60dB shielding efficiency for confidential & EMI-sensitive computer rooms
2Heavy-Duty Reinforced Main KeelKT-ZL-75KITOZERM75mm width, 1.5mm wall thickness, ≥200kg/㎡ load for heavy equipment mounting
3Double-Layer Dust Prevention SystemKT-FC-5KITOZER㎡5-layer composite dust screen with ≥99% filtration for high-cleanliness computer rooms
4Intelligent Lighting Control SystemKT-ZMK-01KITOZERSetHuman body & light sensor control, ≥60% energy saving for unattended computer rooms
5Temperature & Humidity SensorKT-WD-01KITOZERPcCeiling-mounted real-time environmental monitoring for precision computer rooms

V. System Schematic Diagrams

5.1 Structural Schematic of KITOZER Special Ceiling System

Building Floor → Expansion Bolt → Φ8 Full-Thread Suspension Rod (KT-DG-8) → Main Keel KT-ZL-50 (1200mm spacing) → Cross Keel KT-FL-38 (600mm spacing) → Connection Fittings → Microporous Aluminum Panel KT-MP-6060; Sound-absorbing Cotton KT-XY-25 & Dust Screen KT-FC-3 attached to panel rear side; Matching Recessed Light Panel / Ventilation Panel / Access Panel + Earthing System KT-JD-01 → Indoor Computer Room Space

5.2 Air Distribution Principle Diagram

KITOZER ceiling adopts top-supply bottom-return or bottom-supply top-return airflow layout to realize efficient heat dissipation via ventilated and microporous panels:

  1. Cold aisle airflow path: Conditioned cold air → Ventilation Panels → Cold Aisle → Server Air Inlet → Server Air Outlet → Hot Aisle → Return Air Grille → Air Conditioning Unit
  2. Hot aisle airflow path: Hot exhaust air from servers → Hot Aisle → Ceiling plenum return layer → AC return inlet → Refrigeration cycle for recycled cold air supply

Combination of ventilated and microporous panels ensures even airflow distribution, eliminates local hotspots, improves air conditioner efficiency and delivers 20%~30% energy saving.

VI. Core Technical Specifications

6.1 Key Product Technical Parameters (KITOZER)

表格

Product NameCore Technical IndexImplemented Standard
Microporous Aluminum Panel KT-MP-6060Material:6063-T5 Al Alloy; Thickness:0.8mm; Size:600×600mm; Aperture:2mm; Perforation rate:25%; Matte electrostatic powder coating; Flatness≤1.5mm/㎡; Class A fire rating; Tensile strength≥180MPa; Bending strength≥150MPaGB/T 3880-2006, GB 8624-2012, GB 50222-2017
Main Keel KT-ZL-50Hot-dip galvanized steel; 50×20×1.2mm; Zinc coating≥12μm; Load≥120kg/㎡; Straightness deviation≤2mm per 3mGB/T 11253-2007, GB 50009-2012
Sound-Absorbing Cotton KT-XY-25Centrifugal glass wool; 25mm thickness, density 48kg/m³; Average sound absorption ≥0.8 (125~4000Hz); Class A non-combustible; Formaldehyde emission ≤0.05mg/m³GB/T 17795-2019, GB 8624-2012
Ventilation Panel KT-TF-606035% ventilation rate, adjustable 0~90° louver; Aluminum alloy; Max matching airflow 1500m³/h per panel; IP54 tightness when fully closedGB/T 14295-2018
Anti-Static Earthing System KT-JD-01Earthing resistance ≤1Ω; Surface resistance 10⁶~10⁹Ω; Pure copper grounding strip ≥25mm² cross-sectionGB 50174-2017, GB 50057-2010

6.2 Overall System Performance Index

  1. Structural Performance
  • Total Load Bearing: Static load ≥80kg/㎡ + live load ≥70kg/㎡ to support overhead equipment and dense pipeline layout
  • Deflection Control: ≤L/250 (L=keel span) to avoid permanent deformation during long-term operation
  • Service Life: ≥20 years for extended maintenance cycle and reduced lifecycle cost
  1. Environmental Performance
  • Fire Resistance: Class A non-combustible material complying with GB 8624-2012
  • Anti-Static Property: Surface resistance 10⁶~10⁹Ω to eliminate static accumulation and discharge risks
  • Dust Prevention: 3-layer high-density dust screen with ≥95% filtration efficiency to block airborne dust
  • Noise Reduction: Average sound absorption ≥0.8 to reduce indoor noise by 10~15dB and improve working environment
  1. Installation Performance
  • Installation Precision: Surface flatness ≤1.5mm/㎡, joint height difference ≤0.5mm
  • Construction Speed: Max 200㎡ finished per working day to shorten project schedule
  • Easy Maintenance: Single operator detaches one panel within 30 seconds without specialized tools for rapid overhaul

VII. Application Scope

KITOZER dedicated ceiling is applicable for all computer rooms requiring strict environmental control:

7.1 Data Center Projects

Large-scale cloud computing data centers, financial IDC, internet data centers, enterprise private cloud, edge computing data centers, modular & containerized data centers and high-density server rooms

7.2 Conventional Computer Rooms

Government agency computer rooms, military command center equipment rooms, research institute computing labs, core computer rooms for banking, securities & insurance sectors, telecom operator network rooms, power dispatching centers, traffic control hubs and medical imaging centers

7.3 Specialized Environment Computer Rooms

EMI shielded confidential computer rooms, military-grade IT rooms, high-cleanliness microelectronics & semiconductor testing workshops, high-humidity / high-temperature / vibration-prone special industrial computer rooms

7.4 Other Application Fields

Equipment rooms for network devices, server hosting & data backup centers, monitoring & security command centers, precision instrument laboratories, automatic industrial control and IoT data collection centers

VIII. Core Product Advantages vs Conventional Ceiling Products

8.1 Superior Structural Strength

  • Oversized load design exceeding standard ceiling requirements to support heavy overhead equipment and dense wiring layout
  • Anti-deformation construction using high-grade 6063 aluminum alloy and thickened galvanized keels with strict deflection control
  • Earthquake resistance up to Grade 8 suitable for construction in seismic-prone regions

8.2 Optimized Environmental Control

  • Full Class A non-combustible construction meeting top-tier fire safety specifications for IT facilities
  • Triple dustproof structure combining microporous panel, high-efficiency filter screen and sealed edge treatment to stop dust fall
  • High-efficiency sound absorption via 25mm glass wool + perforated panel cutting ambient noise significantly
  • Integrated anti-static coating with regulated surface resistance to prevent static damage to precision electronics

8.3 Optimized Operation & Maintenance

  • Tool-free quick-release panel design cutting overhaul time drastically
  • Fully standardized interchangeable modular components lowering spare part inventory cost
  • Position marking system for fast hidden pipeline and equipment location
  • Reserved expansion ports for later installation of sensors and monitoring devices

8.4 Lifecycle Economic Benefits

  • 20+ year service life, 2~3 times longer than ordinary ceiling materials to lower replacement cost
  • Optimized air distribution reduces air-conditioner power consumption by 20%~30% for sustained energy saving
  • Low routine maintenance requirement cutting long-term labor expenditure
  • Premium specialized ceiling solution improves overall asset value of the whole computer room

8.5 Comprehensive Safety Performance

  • Integrated copper earthing network with total system grounding resistance ≤1Ω eliminating static discharge hazards
  • Anti-drop locking structure preventing accidental panel falling to protect on-site staff safety
  • Reserved fire linkage interface enabling automatic smoke exhaust opening triggered by fire alarm system

IX. Tender Specification Parameters for Bid Customization

9.1 Core Mandatory Technical Specifications

  1. Panel Requirements
  • Raw material strictly 6063-T5 high-strength aluminum alloy complying with GB/T 3880-2006
  • Minimum thickness ≥0.8mm; tensile strength ≥180MPa, bending strength ≥150MPa
  • Standard size 600×600mm; surface flatness ≤1.5mm/㎡, edge verticality tolerance ≤0.5mm
  • Fixed 2mm aperture & 25% perforation rate with triple-layer dust filter ≥95% filtration efficiency
  1. Keel System Requirements
  • Main keel: minimum 50mm width with ≥1.2mm hot-dip galvanized steel wall; load ≥120kg/㎡
  • Cross keel: minimum 38mm width with ≥1.0mm steel wall; fixed 600mm installation spacing
  • Φ8 full-thread suspension rod with single-set bearing ≥1kN; zinc coating ≥12μm passing ≥1000-hour salt spray anti-corrosion test
  1. System Overall Performance
  • Full system Class A non-combustible per GB 8624-2012
  • Anti-static surface resistance 10⁶~10⁹Ω, system grounding resistance ≤1Ω complying with GB 50009
  • Static ≥80kg/㎡ + live ≥70kg/㎡ load capacity
  • Average sound absorption coefficient ≥0.8 within 125~4000Hz frequency band
  • Installation flatness ≤1.5mm/㎡, panel joint gap difference ≤0.5mm
  1. Brand & After-Sales Service Terms
  • Products exclusively manufactured by KITOZER (Kaituozhe) / Guangdong Lai’an Intelligent Computer Room Equipment Co., Ltd.
  • Minimum 10-year product warranty with lifetime maintenance service
  • Valid ISO9001 Quality Management & ISO14001 Environmental Management System certifications
  • Full technical guidance & 24-hour responsive after-sales support

X. Detailed Bid Tender Specifications

10.1 Compulsory Bid Requirements

  1. Bidder must provide original KITOZER manufacturer authorization certificate and formal after-sales commitment letter
  2. Ceiling system must obtain Class A fire resistance certification issued by national authorized fire testing institute
  3. Aluminum panel 6063-T5 with ≥0.8mm thickness with official material inspection report submitted
  4. System total load capacity static ≥80kg/㎡ + live ≥70kg/㎡ supported by third-party test certificate
  5. Anti-static performance (10⁶~10⁹Ω surface resistance, ≤1Ω grounding resistance) verified via authorized inspection document

10.2 Detailed Technical Bid Specifications

表格

Technical IndexBid RequirementReference Test Standard
Panel Dimension600×600mm, ≥0.8mm thickness, flatness≤1.5mm/㎡GB/T 3880-2006
Keel SizeMain keel ≥50×20×1.2mm; cross keel≥38×15×1.0mmGB/T 11253-2007
Panel Perforation20%~30% adjustable perforation rate, uniform 2mm round holesIndustrial Specification
Dust Filter Performance≥95% filtration via triple-layer composite screenGB/T 14295-2018
Sound AbsorptionAverage absorption ≥0.8 from 125Hz~4000HzGB/T 17795-2019
Fire GradeFull system Class A non-combustibleGB 8624-2012
Design Lifespan≥20 years with durability test reportEnterprise Standard
Seismic RatingGrade 8 earthquake resistance with authorized test certificateGB 50011-2010

10.3 Commercial & Service Bid Clauses

  1. Minimum 10-year free product warranty covering free spare part replacement within warranty period plus lifetime paid maintenance
  2. Professional in-house installation team providing on-site installation training & technical guidance
  3. Full set of technical documents including installation, operation and maintenance manuals supplied upon delivery
  4. Bidder to provide at least five completed similar project contracts and client acceptance documents as project references
  5. 24-hour remote technical support with on-site troubleshooting within 48 hours upon service request

XI. Customized Project Solutions

11.1 High-Density Data Center Ceiling Solution

Project Focus: High heat dissipation, heavy load capacity and intelligent environmental control for dense server deployment

Core Configuration: High-perforation ventilation panels (30% open area) + reinforced heavy-duty keel (≥150kg/㎡ load), auto-adjust intelligent ventilation control, double-layer high-efficiency ≥99% dust filtration system

Project Outcome: Uniform airflow eliminates hotspots, 25% higher AC efficiency; robust structure supports dense equipment & cabling layout; intelligent control delivers up to 30% power saving and extends server service life

11.2 Confidential EMI-Shielded Computer Room Solution

Project Focus: Full-spectrum electromagnetic shielding, anti-static and fire protection for classified information storage rooms

Core Configuration: ≥60dB EMI shielding panels + integrated shielded keel + full-range copper earthing network, conductive connecting fittings and full Class A fireproof sealed construction

Project Outcome: Effectively blocks external electromagnetic leakage & interference complying with national classified information security B-level standard; eliminates static leakage risks to protect confidential data security

11.3 Fast-Track Modular Computer Room Solution

Project Focus: Shortened construction schedule with prefabricated modular design for standardized modular data center construction

Core Configuration: Factory preassembled integrated modules embedding lighting, ventilation and fire protection interfaces with quick snap-fit installation without complex fixed fittings

Project Outcome: On-site construction duration cut by over 50% (from 30 days down to around 10 days); standardized design enables easy future expansion and low-cost routine maintenance with unified neat appearance

11.4 Legacy Computer Room Renovation Solution

Project Focus: Minimal structural modification during on-site upgrade for aged ceiling with poor load, dust and anti-static performance; zero or minimum downtime for in-service computer rooms

Core Configuration: Lightweight retrofit ceiling compatible with original building structure without concrete reinforcement; phased partial installation to avoid full-room shutdown; upgraded dustproof, anti-static and acoustic features

Project Outcome: Continuous normal IT operation during staged renovation; upgraded indoor environment extends server lifespan with over 20% energy efficiency improvement and high investment return rate

XII. Real-World Application Cases

12.1 Case 1: South China Cloud Computing Data Center (Guangzhou)

  • Overview: Total ceiling area 15,000㎡, ceiling height 4.2m; high-density server layout with intensive heat output and heavy overhead load requirement
  • Adopted Product: KITOZER high-ventilation ceiling system (KT-MP-6060 + KT-TF-6060)
  • Project Result: 30% adjustable ventilation rate satisfies intensive heat dissipation; full load specification meets design requirement; total construction finished in 28 days (15 days faster than traditional ceiling); finished surface flatness controlled within 1.2mm below standard threshold

12.2 Case 2: Guangdong Provincial Government Cloud Confidential Data Center

  • Overview: Total ceiling area 3,000㎡, ceiling height 3.5m; high confidential level requiring strict EMI shielding and anti-static construction
  • Adopted Product: KITOZER EMI shielding dedicated ceiling (KT-PB-6060 + KT-JD-01 full earthing set)
  • Project Result: Actual shielding efficiency reaches 65dB complying with national Class B confidential specification; anti-static index fully compliant with GB 50174-2017 and passed official national confidentiality authority acceptance test

12.3 Case3: China Merchants Bank Disaster Backup Data Center (Shenzhen)

  • Overview: Total ceiling area 5,000㎡, ceiling height 4.0m; 24/7 uninterrupted financial core operation requiring convenient regular equipment maintenance
  • Adopted Product: KITOZER easy-overhaul dedicated ceiling with reinforced access panels (KT-MP-6060+KT-JX-6060)
  • Project Result: 50% faster field maintenance via quick-release panels; high load-bearing structure fits redundant backup equipment layout; zero ceiling failure recorded over 10-year continuous operation ensuring stable financial service continuity

12.4 Case4: The First Affiliated Hospital of Sun Yat-sen University Medical Imaging Center

  • Overview: Total ceiling area 1,200㎡, ceiling height 3.2m; high cleanliness requirement for precision medical diagnostic imaging equipment
  • Adopted Product: KITOZER high-cleanliness ceiling with five-layer ultra-fine dust screen (KT-MP-6060+KT-FC-5)
  • Project Result: 99.9% ultra-high dust filtration prevents fine dust damaging precision medical devices; low-noise construction improves diagnostic working environment; system fully passes medical EMC compatibility testing for radiology equipment

XIII. SEO Keywords & Tags

13.1 Core Search Keywords

KITOZER dedicated computer room ceiling, computer room suspended ceiling system, data center ceiling solution, microporous aluminum computer room ceiling, Guangdong Lai’an intelligent computer room equipment, anti-static computer room ceiling, fireproof IT room ceiling, modular data center ceiling, EMI shield ceiling for confidential room, high airflow ceiling for high-density server room, tender specification for computer room ceiling

13.2 SEO Optimized Phrases

Dedicated computer room ceiling solution, KITOZER IT room ceiling, data center overhead ceiling design, computer room ceiling construction specification, ceiling technical standard for data center, ceiling product advantage & application cases, tender parameter of IT room ceiling, ceiling supplier for computer room project

13.3 Hashtags

#KITOZERComputerRoomCeiling #DataCenterCeiling #AntiStaticITCeiling #FireproofServerRoomCeiling #ModularDataCenterConstruction #EMIShieldCeiling #GuangdongLaiAnEquipment #ComputerRoomRenovationSolution

Shopping Cart