Table of Contents
ToggleI. System Introduction
1.1 System Overview
The KITOZER Auxiliary Materials System for Server Room Decoration is a professional auxiliary solution designed exclusively for precision electronic equipment environments such as data centers, server rooms and network rooms. It mainly includes edge banding, sealant, gaskets and supporting auxiliary materials, aiming to solve the four core issues of sealing, protection, decoration and insulation in server room decoration. It meets the special requirements of cleanliness, temperature & humidity control, electromagnetic shielding and fire resistance in server rooms. Adopting a modular design, it adapts to various decoration scenarios from walls, floors to ceilings, and from cabinet installation to pipeline penetration, providing all-round professional auxiliary support to ensure a stable and reliable overall environment, extend equipment service life and reduce operation & maintenance costs.
1.2 Design Philosophy
Centered on “Precision Protection, Safety & Reliability”, the system follows these principles:
- Complies with GB 50174-2017 Code for Design of Data Centers
- Compatible with all server room decoration materials (color steel plate, anti-static floor, aluminum alloy keel, etc.)
- Multi-functional: fireproof, moisture-proof, mildew-proof, dust-proof and anti-static
- Easy construction, improved installation efficiency and reduced labor cost
- Eco-friendly, RoHS-compliant, safe for on-site personnel
1.3 System Value
| Value Dimension | Specific Performance |
|---|---|
| Environment Protection | Isolates dust, moisture and harmful gases; maintains constant temperature & humidity |
| Equipment Protection | Reduces vibration and EMI; prevents short circuit and corrosion; extends service life |
| Energy Saving | Optimizes sealing; reduces air mixing; cuts HVAC energy consumption by 15%–20% |
| Safety Enhancement | Flame-retardant materials delay fire spread; provides extra evacuation time |
| O&M Convenience | Modular design for easy maintenance and expansion; lowers upkeep cost |
II. System Composition
2.1 Core Components
| Component Category | Main Products | Function Description |
|---|---|---|
| Edge Banding Series | PVC edge banding, ABS edge banding, metal edge banding | Edge protection, decoration, moisture & stain resistance; for color steel plate, anti-static floor, ceiling panel |
| Sealant Series | Neutral silicone sealant, fireproof sealant, conductive sealant | Gap filling, waterproof sealing, fire resistance, EMI shielding; for walls, floors, cabinets, pipelines |
| Gasket Series | Silicone foam gasket, EPDM gasket, PU foam gasket | Cabinet & door/window sealing, gap filling; dust-proof, waterproof, sound insulation |
| Supporting Auxiliary Materials | Tape, fasteners, cleaning supplies, tools | Auxiliary installation, surface treatment, improved quality & efficiency |
2.2 System Architecture
KITOZER Server Room Auxiliary Materials System
├── Edge Banding Module (Wall/Floor/Ceiling)
│ ├── Standard Edge Banding
│ ├── Fireproof Edge Banding
│ ├── Anti-Static Edge Banding
│ └── Special-Shaped Edge Banding
├── Sealant Module (General/Special)
│ ├── General-Purpose Sealant
│ ├── Fireproof Sealant
│ ├── Conductive Sealant
│ └── Weather-Resistant Sealant
├── Gasket Module (Cabinet/Door/Pipeline)
│ ├── Cabinet Special Gasket
│ ├── Door & Window Gasket
│ ├── Pipeline Penetration Seal
│ └── Shock-Absorbing Buffer Strip
└── Supporting Auxiliary Module
├── Double-Sided Tape
├── Fixing Buckle
├── Cleaning Solvent
└── Special Construction Tools

III. System Classification
3.1 By Function
| Category | Representative Products | Application Scenarios | Core Features |
|---|---|---|---|
| Sealing & Protection | Sealant, Gasket | Wall gaps, door frames, cabinet installation, pipeline penetration | IP65 dust & waterproof; temp range -40℃~150℃; elasticity recovery ≥80% |
| Edge Treatment | Edge Banding, Trim Strip | Color steel plate joint, anti-static floor edge, ceiling closing | Flame retardant V-0; Taber abrasion ≤10mg; anti-aging ≥10 years |
| Function Enhancement | Conductive sealant, Anti-static edge banding | EMI-shielded room, ESD area | Surface resistance 10⁶–10⁹Ω; shielding effectiveness ≥60dB |
| Auxiliary Installation | Tape, Fasteners, Tools | Auxiliary mounting, positioning, cleaning | High-strength bonding; corrosion-resistant; easy construction |
3.2 By Material
| Material Type | Representative Products | Performance | Application Environment |
|---|---|---|---|
| Organic Polymer | PVC edge banding, Silicone sealant | High flexibility, easy processing, chemical resistance | General server rooms, non-extreme temperature zones |
| Inorganic Material | Fireproof sealant, Metal edge banding | Excellent fireproof, high temperature resistance, high strength | Class A fireproof rooms, high-temperature areas |
| Composite Material | Composite foam gasket, Modified sealant | Balanced performance, complex environment adaptation | Precision rooms, multi-factor environments |
| Elastomer | EPDM gasket, Silicone sealant | High elasticity, strong resilience, anti-aging | Vibration areas, frequent opening/closing parts |
3.3 By Application Area
| Application Area | Recommended Product Combination | Core Function |
|---|---|---|
| Wall System | Color steel plate edge banding + Neutral silicone sealant + Corner trim | Seals wall gaps, decorates edges, prevents dust accumulation |
| Floor System | Anti-static floor edge banding + Conductive sealant + Floor trim | Anti-static, moisture-proof, wear-resistant, smooth transition |
| Ceiling System | Ceiling edge banding + Fireproof sealant + Hanger fastener | Fireproof, sound insulation, decoration, auxiliary fixing |
| Cabinet Zone | Cabinet gasket + Conductive sealant + Cabinet foot pad | Dust-proof, shockproof, EMI shielding, noise reduction |
| Pipeline System | Pipeline sealant + Penetration seal + Fixing buckle | Seals pipeline holes, prevents air mixing, fixes pipelines |

IV. System Configuration List (Brand: KITOZER)
4.1 Edge Banding Series
| No. | Product Name | Model | Specification | Material | Qty | Application |
|---|---|---|---|---|---|---|
| 1 | Server Room Special PVC Edge Banding | KT-FB-PVC-01 | 20mm×1.0mm | Eco PVC + Flame Retardant | As required | Color steel plate wall, ceiling edge |
| 2 | Anti-Static Edge Banding | KT-FB-AS-02 | 25mm×1.2mm | PVC + Carbon + Anti-Static Agent | As required | Anti-static floor, ESD area |
| 3 | Metal Trim Strip | KT-FB-MT-03 | 30mm×0.8mm | 304 Stainless Steel | As required | Wall-floor transition, doorway trim |
| 4 | Special-Shaped Edge Banding | KT-FB-SP-04 | Custom | PVC/Aluminum Alloy | As required | Special-shaped plates, irregular edges |
| 5 | Fireproof Edge Banding | KT-FB-FR-05 | 20mm×1.0mm | Flame-Retardant PVC + Fiberglass | As required | Class A fireproof rooms, fire passages |
4.2 Sealant Series
| No. | Product Name | Model | Specification | Material | Qty | Application |
|---|---|---|---|---|---|---|
| 6 | Neutral Silicone Sealant | KT-SJ-SN-01 | 310ml/pc | Neutral Silicone + Crosslinking Agent | As required | General gap sealing, waterproof & dust-proof |
| 7 | Fireproof Sealant | KT-SJ-FR-02 | 310ml/pc | Inorganic Filler + Silicone Matrix | As required | Firewall, fire compartment sealing |
| 8 | Conductive Sealant | KT-SJ-CN-03 | 310ml/pc | Silicone + Conductive Filler | As required | EMI-shielded room, grounding parts |
| 9 | High-Temperature Sealant | KT-SJ-HT-04 | 310ml/pc | Modified Silicone + High-Temp Filler | As required | High-temperature equipment, ventilation duct |
| 10 | Mildew-Proof Sealant | KT-SJ-MF-05 | 310ml/pc | Silicone + Mildew inhibitor | As required | Humid areas, condensation-prone parts |
4.3 Gasket Series
| No. | Product Name | Model | Specification | Material | Qty | Application |
|---|---|---|---|---|---|---|
| 11 | Cabinet Special Gasket | KT-ST-JG-01 | Custom Length | Closed-Cell EPDM Foam | As required | Cabinet frame, equipment box |
| 12 | Door & Window Gasket | KT-ST-MC-02 | Custom Length | Silicone Foam | As required | Server room door, observation window |
| 13 | Pipeline Penetration Seal | KT-ST-GX-03 | Fit Pipe Diameter | Composite Foam | As required | Cable & pipe wall penetration |
| 14 | Shock-Absorbing Buffer Strip | KT-ST-FZ-04 | 20mm×10mm | Rubber Elastomer | As required | Equipment installation, vibration isolation |
4.4 Supporting Auxiliary Series
| No. | Product Name | Model | Specification | Material | Qty | Application |
|---|---|---|---|---|---|---|
| 15 | Double-Sided Tape | KT-AC-DS-01 | 50mm×50m | Acrylic + PET | As required | Temporary fixing & positioning |
| 16 | Fixing Buckle | KT-AC-FK-02 | Fit Edge Banding | Galvanized Steel | As required | Edge banding fixing, anti-falling |
| 17 | Cleaning Solvent | KT-AC-QJ-03 | 500ml/bottle | Eco Cleaner | As required | Surface cleaning, bonding improvement |
| 18 | Special Tool Kit | KT-AC-GJ-04 | Caulking gun, roller, scraper | Metal + Engineering Plastic | 1 set/team | Auxiliary installation, efficiency improvement |

V. System Schematic Diagram
5.1 System Architecture Diagram
┌─────────────────────────────────────────────┐
│ KITOZER Server Room Auxiliary System │
│ ┌───────────┐ ┌───────────┐ ┌───────────┐ │
│ │Edge Banding│ │ Sealant │ │ Gasket │ │
│ └─────┬─────┘ └─────┬─────┘ └─────┬─────┘ │
│ │ │ │ │
│ ┌─────▼─────┐ ┌─────▼─────┐ ┌─────▼─────┐ │
│ │Edge Treatmt│ │Gap Sealing│ │Elas. Protec│ │
│ └─────┬─────┘ └─────┬─────┘ └─────┬─────┘ │
│ │ │ │ │
│ ┌─────▼───────────────▼───────────────▼─────┐ │
│ Supporting Auxiliary Module │
│ └─────┬───────────────┬───────────────┬─────┘ │
└────────┼───────────────┼───────────────┼────────┘
│ │ │
┌────────▼─────┐ ┌─────▼─────┐ ┌─────▼─────┐
│ Wall Deco Sys│ │Floor Deco Sys│ │Ceiling Deco Sys│
└─────────────┘ └─────────────┘ └─────────────┘
│ │ │
┌────────▼─────┐ ┌─────▼─────┐ ┌─────▼─────┐
│Cabinet Area │ │Pipeline Area│ │Door/Window Area│
└─────────────┘ └─────────────┘ └─────────────┘
5.2 Typical Application Node Schematic
5.2.1 Color Steel Plate Wall Sealing
┌─────────────┐ ┌─────────────┐
│ Color Steel A│ │ Color Steel B│
│ ┌─────────┐│ │┌─────────┐ │
│ │Edge Band││ ││Edge Band│ │
│ │KT-FB-PVC││ ││KT-FB-PVC│ │
│ └────┬────┘│ │└────┬────┘ │
│ └─────┼──────┼─────┘ │
│ │ │ │
│ ┌─────▼──────▼─────┐ │
│ │ Sealant │ │
│ │ KT-SJ-SN-01 │ │
│ └─────────────────┘ │
└─────────────────────────────────┘
5.2.2 Cabinet Sealing
┌─────────────────────────────┐
│ Cabinet Frame │
│ ┌─────────────────────┐ │
│ │ Gasket │ │
│ │ KT-ST-JG-01 │ │
│ └─────────────────────┘ │
│ ┌─────────────────────┐ │
│ │ Conductive Sealant │ │
│ │ KT-SJ-CN-03 │ │
│ └─────────────────────┘ │
└─────────────────────────────┘
│
▼
┌─────────────────────────────┐
│ Cabinet Door │
└─────────────────────────────┘

VI. Product Technical Parameters
6.1 Edge Banding Series
| Model | Material | Size (W×T) | Fire Rating | Surface Resistance | Temp Range | Taber Abrasion | Anti-Aging |
|---|---|---|---|---|---|---|---|
| KT-FB-PVC-01 | Eco PVC + FR | 20mm×1.0mm | V-0 | ≥10¹²Ω | -20℃~80℃ | ≤10mg | ≥10y |
| KT-FB-AS-02 | PVC + Carbon + AS | 25mm×1.2mm | V-0 | 10⁶–10⁹Ω | -20℃~80℃ | ≤8mg | ≥10y |
| KT-FB-MT-03 | 304 Stainless Steel | 30mm×0.8mm | Class A | Conductor | -50℃~200℃ | Extreme | ≥20y |
| KT-FB-SP-04 | PVC/Al Alloy | Custom | By material | By material | By material | By material | By material |
| KT-FB-FR-05 | FR PVC + Fiberglass | 20mm×1.0mm | Class A | ≥10¹²Ω | -20℃~100℃ | ≤12mg | ≥15y |
6.2 Sealant Series
| Model | Type | Color | Tack-Free Time | Curing Time | Tensile Strength | Elongation | Temp Range | Bonding Substrate |
|---|---|---|---|---|---|---|---|---|
| KT-SJ-SN-01 | Neutral Silicone | Clear/White/Black | ≤30min | 24h | ≥0.6MPa | ≥300% | -40℃~150℃ | Metal, Plastic, Glass |
| KT-SJ-FR-02 | Fireproof Silicone | Gray | ≤45min | 48h | ≥0.8MPa | ≥200% | -40℃~200℃ | Concrete, Metal, Stone |
| KT-SJ-CN-03 | Conductive Silicone | Black | ≤30min | 24h | ≥0.5MPa | ≥250% | -40℃~150℃ | Metal, Conductive Plastic |
| KT-SJ-HT-04 | High-Temp Silicone | Clear/Red | ≤45min | 48h | ≥0.7MPa | ≥200% | -40℃~250℃ | Metal, Ceramic, Glass |
| KT-SJ-MF-05 | Mildew-Proof Silicone | White/Clear | ≤30min | 24h | ≥0.6MPa | ≥300% | -40℃~150℃ | Wood, Plastic, Metal |
6.3 Gasket Series
| Model | Material | Shape | Density | Hardness | Compression Set | Waterproof | Application |
|---|---|---|---|---|---|---|---|
| KT-ST-JG-01 | Closed-Cell EPDM | Rect/Round | 0.3g/cm³ | 30±5 Shore A | ≤15% | IP65 | Cabinet Frame |
| KT-ST-MC-02 | Silicone Foam | Special | 0.25g/cm³ | 25±5 Shore A | ≤10% | IP66 | Door & Window |
| KT-ST-GX-03 | Composite Foam | Ring | 0.4g/cm³ | 35±5 Shore A | ≤20% | IP65 | Pipeline Penetration |
| KT-ST-FZ-04 | Rubber Elastomer | Strip | 0.9g/cm³ | 40±5 Shore A | ≤12% | IP54 | Shock Absorption |
VII. Application Scope
7.1 Server Room Type Adaptation
| Room Type | Recommended Product Combination | Core Demand |
|---|---|---|
| Data Center | Fireproof edge banding + Fireproof sealant + Conductive gasket | Class A fireproof, EMI shielding, IP65 |
| Network Room | PVC edge banding + Neutral sealant + Standard gasket | General protection, decoration, cost-effective |
| Server Room | Anti-static edge banding + Conductive sealant + Shockproof gasket | Anti-static, EMI shielding, anti-vibration |
| Edge Computing Room | Composite edge banding + Weather-resistant sealant | Multi-environment adaptation, easy installation |
| Military-Grade Room | Metal edge banding + Fireproof sealant | High strength, reliability, long life |
7.2 Application Scenarios
- New server room decoration: full-system coverage from base construction to equipment installation
- Server room renovation: gap & edge reinforcement to improve overall performance
- Capacity expansion: transition between new & existing areas to maintain environment consistency
- Precision equipment periphery: sealing around servers, network devices, UPS
- Special environment: high-altitude, high-temperature, high-humidity, salt-spread rooms
- Clean room: pharmaceutical, semiconductor; dust-grade auxiliary support

VIII. Product Advantages
8.1 Core Advantages
| Advantage Category | Performance | Technical Support |
|---|---|---|
| Professional Adaptation | Designed for server rooms; complies with GB 50174-2017 | Optimized formula, customized parameters |
| Comprehensive Protection | Fireproof, moisture-proof, mildew-proof, dust-proof, anti-static, EMI shielding | Multi-material combination, functional complement |
| Long Service Life | ≥10 years under normal use; reduces replacement | Anti-aging formula, premium raw materials |
| Easy Construction | Modular, self-adhesive, fast curing; efficiency +50% | Prefabricated production, special tools |
| Eco-Friendly | RoHS-compliant; no formaldehyde/heavy metal; VOC ≤50g/L | Green formula, strict QC |
| Cost-Effective | Total cost -30%; low maintenance | High value, long life, low failure rate |
8.2 Comparison with Ordinary Decoration Auxiliary Materials
| Item | KITOZER Server Room Special | Ordinary Decoration Auxiliary | Advantage |
|---|---|---|---|
| Fire Rating | Up to Class A | Usually B or lower | Delays fire spread |
| Temp Range | -40℃~150℃ | -10℃~60℃ | Adapts to HVAC temperature swings |
| Elastic Recovery | ≥80% | ≤50% | Durable sealing, no deformation |
| Eco Standard | RoHS, GB 18583 | General standard | Safe for personnel |
| Compatibility | Tailored for server room materials | General-purpose | Strong bonding, no falling |
| Function | Multi-functional (fireproof, anti-static, shielding) | Single decoration | Meets special needs |
IX. Bid Evaluation Parameters
9.1 Edge Banding Series
| Index | Bid Requirement | Standard |
|---|---|---|
| Fire Performance | V-0, LOI ≥28% | GB/T 8627-2007 |
| Dimensional Accuracy | Thickness ±0.1mm, Width ±0.2mm | GB/T 18145-2014 |
| Wear Resistance | Taber weight loss ≤10mg | ISO 9352:2012 |
| Anti-Aging | UV 500h: no crack, no discoloration | GB/T 16422.3-2014 |
| Eco Index | Formaldehyde ≤0.05mg/m³, VOC ≤50g/L | GB 18583-2008 |
| Anti-Static | Surface resistance 10⁶–10⁹Ω (AS type) | GB/T 1410-2006 |
9.2 Sealant Series
| Index | Bid Requirement | Standard |
|---|---|---|
| Physical Property | Tensile ≥0.6MPa, Elongation ≥300% | GB/T 14683-2017 |
| Curing Property | Tack-free ≤30min, full cure ≤24h | GB/T 13477.5-2017 |
| Weather Resistance | UV 1000h: no crack, no chalking | GB/T 16777-2008 |
| Bonding Strength | To color steel plate/aluminum ≥0.8MPa | GB/T 13477.8-2017 |
| Fire Performance | Class A per GB 23864-2009 | GB 23864-2009 |
| Conductivity | Volume resistivity ≤10³Ω·cm (conductive type) | GB/T 1410-2006 |
9.3 Gasket Series
| Index | Bid Requirement | Standard |
|---|---|---|
| Sealing | IP65 or above | GB/T 4208-2017 |
| Elasticity | Compression set ≤15% (70℃×22h) | GB/T 7759-2015 |
| Temp Resistance | -40℃~150℃, no crack/deformation | GB/T 1690-2010 |
| Anti-Aging | Heat aging 70℃×168h: retention ≥80% | GB/T 3512-2014 |
| Material | Halogen-free, RoHS-compliant | IEC 62321-2008 |
| Dimensional Accuracy | Section ±0.1mm, Length ±0.5% | GB/T 3098.1-2010 |

X. Product Solutions
10.1 New Server Room Full-System Solution
10.1.1 Wall System
Solution: KITOZER Color Steel Plate Wall Sealing & Protection
- Clean edges with KT-AC-QJ-03
- Apply KT-FB-PVC-01 edge banding at joints
- Fill gaps with KT-SJ-SN-01 (IP65)
- Corner closing with KT-FB-SP-04
- Fireproof sealing with KT-SJ-FR-02 at intersections Effect: 100% gap sealing; Class A fireproof; dust accumulation reduced by 90%
10.1.2 Floor System
Solution: KITOZER Anti-Static Floor Edge Treatment
- Clean base floor
- Edge banding with KT-FB-AS-02 (10⁶–10⁹Ω)
- Gap filling with KT-SJ-CN-03 for ESD continuity
- Transition with KT-FB-MT-03 Effect: Stable anti-static; flat & sealed; less dust & static
10.1.3 Cabinet Zone
Solution: KITOZER Cabinet Sealing & Protection
- Clean cabinet frame with KT-AC-QJ-03
- Install KT-ST-JG-01 gasket (IP65)
- Seal with KT-SJ-CN-03 (shielding ≥60dB)
- Shock absorption with KT-ST-FZ-04
- Cable hole sealing with KT-ST-GX-03 Effect: Cleanliness improved; failure rate -20%; energy consumption -15%~20%
10.2 Server Room Renovation Solution
Solution: KITOZER Server Room Gap Sealing Enhancement
- Inspect and mark gaps
- Clean old sealant & dust with KT-AC-QJ-03
- Fill wide gaps with KT-ST-GX-03; narrow gaps with KT-SJ-SN-01
- Edge decoration with KT-FB-PVC-01
- Fire compartment sealing with KT-SJ-FR-02 Effect: Sealing improved; energy -10%~15%; equipment life +15%; maintenance -20%
XI. Application Cases
Case 1: Large Cloud Data Center (New Construction)
- Scale: 1000㎡, 300 cabinets
- Products: Edge banding (PVC/fireproof/special), sealant (neutral/fireproof/conductive), gasket (cabinet/pipeline), cleaner, tool kits Effect: IP65 sealing; dust ≤0.5mg/m³; Class A fireproof; HVAC energy -18%; construction period -15 days; Uptime Tier III certified
Case 2: Financial Institution Data Center (Renovation)
- Background: 5-year-old room with aging sealing & dust accumulation
- Products: Neutral/fireproof sealant, cabinet/pipeline gasket, cleaner, tools Effect: Sealing from 60% to 100%; dust -85%; failure rate -25%; maintenance -30%; energy -12%; 7-day renovation without shutdown
Case 3: Research Institute Supercomputing Center
- Requirement: High anti-static & EMI shielding
- Products: Anti-static/metal edge banding, conductive/neutral sealant, cabinet/shock gasket, cleaner, tools Effect: Surface resistance 10⁶–10⁹Ω; shielding 65dB; temp fluctuation ±0.5℃; national lab accreditation; industry benchmark
XII. Search Keywords, SEO & Tags
12.1 Core Search Keywords
Server room decoration auxiliary materials, server room special edge banding, server room sealant, KITOZER server room auxiliary materials, data center auxiliary materials, server room sealing solution, server room fireproof edge banding, server room anti-static sealant, color steel plate edge banding, cabinet gasket
12.2 SEO Keywords
- Core: Server room decoration auxiliary materials, server room edge banding, server room sealant
- Long-tail: Data center edge banding, server room fireproof sealant, KITOZER auxiliary solution
- Functional: Fireproof auxiliary, anti-static auxiliary, EMI shielding auxiliary
- Application: Color steel plate auxiliary, anti-static floor edge banding, cabinet sealing
12.3 Tags
#ServerRoomDecoration #AuxiliaryMaterials #EdgeBanding #Sealant #KITOZER #DataCenter #ServerRoom #Fireproof #AntiStatic #EMIShielding #SealingSolution #RoomRenovation #PrecisionRoom