Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32
KITOZER
KITOZER

Anti-Static Raised Access Floor System | KITOZER

Engineering verification notice: Panel thickness, load class, electrical resistance, fire rating, humidity range, grounding, installation method and compliance standards are project-specific. Final values require an approved data sheet and formal quotation.

Table of Contents

I. System Introduction

1.1 System Overview

The dedicated anti-static raised access floor system for computer rooms is a professional flooring solution designed for data centers, computer server rooms and other electronic information premises. Centered on three core capabilities including anti-static protection, overhead cabling and load-bearing support, it builds a safe operating environment for precision electronic equipment to avoid damages caused by electrostatic discharge (ESD). Meanwhile, it creates concealed installation space for strong/weak current cables, air conditioning ventilation ducts and fire protection pipelines to realize tidy layout and convenient maintenance of computer rooms.

Manufactured with modular design, KITOZER anti-static raised floor system features high load capacity, permanent anti-static property, Class A fire resistance, moisture proofing, abrasion and corrosion resistance, complying with national standards including GB 50174-2017 Code for Design of Data Center and GB/T 36340-2018 General Specification for Anti-Static Raised Access Floor. It serves as essential infrastructure for modern computer room construction.

1.2 Core Functions

  1. Static Electricity Prevention: Static charges are rapidly diverted to earth via conductive network; surface resistance is controlled between 10⁶~10⁹Ω for static dissipative type or 10⁴~10⁶Ω for conductive type to eliminate ESD risks to electronic devices.
  2. Overhead Cabling: Adjustable overhead clearance ranging from 150mm to 600mm facilitates cable laying, management and flexible layout modification of computer rooms.
  3. Load Bearing: Concentrated point load ≥1000kg and uniformly distributed load ≥1200kg/m² to support heavy-duty equipment such as server cabinets and precision air conditioners.
  4. Environmental Adaptability: Class A fire rating, waterproof & damp-proof, acid and alkali resistant to fit constant temperature & humidity working conditions of computer rooms.
  5. Easy Maintenance: Modular structure allows single-panel quick removal for overhaul of underfloor pipelines and embedded facilities.

II. System Composition

KITOZER anti-static raised floor system consists of five core components working synergistically for full-system performance:

表格

Component CategoryKey PartsFunction Description
Floor PanelAll-steel faceplate, core filler, anti-static veneer, conductive edge stripLoad bearing, static prevention, abrasion resistance and decoration; standard specification 600×600mm
Support SystemAdjustable pedestal, stringer beam, base plateStable structural support, adjustable overhead height and grid frame formation
Conductive SystemEarthing copper strip, conductive rubber strip, earthing terminal, protective resistance boxForm continuous conductive path to drain static to ground; overall earthing resistance ≤4Ω
Auxiliary FittingsVentilation floor, ramp trim, edge closing strip, screws & fastenersMeet special functional requirements, optimize installation and ensure site safety
Installation ToolsLaser level, resistance tester, rubber mallet, measuring tapeGuarantee installation precision and qualified anti-static performance

2.1 Detailed Introduction of Core Components

2.1.1 Floor Panel Structure

  1. Base Layer: 0.8~1.2mm cold-rolled steel sheets for top and bottom panels, welded into closed cavity frame for structural rigidity.
  2. Filling Layer: Foamed cement or calcium sulfate core for high compression resistance; calcium sulfate variant delivers superior moisture resistance.
  3. Anti-static Layer: HPL high-pressure laminate or PVC anti-static veneer with evenly dispersed conductive particles for long-lasting static dissipation.
  4. Conductive Edge Strip: Conductive rubber trim fitted on panel edges to ensure electrical continuity between adjacent floor panels and complete conductive network formation.

2.1.2 Support System Structure

  1. Adjustable Pedestal: Hot-dip galvanized all-steel structure with adjustable height 150~600mm, single-piece bearing capacity ≥1000kg.
  2. Stringer Beam: Galvanized steel material linking pedestals to build 600×600mm grid with inherent electrical conductivity.
  3. Base Plate: Thickened steel base to expand ground contact area, prevent pedestal sinking and adapt to various base floor conditions.

2.1.3 Working Principle of Conductive System

Static charges follow the discharging path: Floor Panel → Conductive Edge Strip → Stringer Beam → Pedestal → Earthing Copper Strip → Earthing Terminal → Building Earthing Grid → Earth. A minimum of one earthing terminal is arranged per 100㎡; grounding wire adopts multi-strand copper cable with cross-sectional area ≥4mm² fitted with 1MΩ±10% current-limiting resistor to avoid surge current damage.

III. System Classification

3.1 By Structural Type

表格

CategoryFeaturesApplicable Scenarios
Raised Access TypeHeight adjustable, detachable, maximum underfloor cabling space, easy maintenanceData centers, server rooms and large-scale computer rooms requiring frequent underfloor inspection
Direct-laid TypeDirect installation on base floor without underfloor cavity, quick constructionSmall computer rooms, monitoring control rooms and office spaces with low cabling demand

3.2 By Base Material

表格

CategoryStructureCore AdvantagesApplication Scenarios
All-Steel Anti-Static Floor (KITOZER Flagship)Double steel sheet + foamed cement/calcium sulfate fillingHigh load capacity, Class A fireproof, waterproof & damp-proof, service life ≥20 yearsLarge data centers, financial computer rooms, IDC premises
Aluminum Alloy Anti-Static FloorAluminum panel + honeycomb/foam coreLightweight, superior corrosion resistance and heat dissipationCleanrooms, laboratories and precision instrument workshops
Calcium Sulfate Anti-Static FloorCalcium sulfate core wrapped with galvanized steel sheetEco-friendly, stable dimensional tolerance and sound insulationOffice computer rooms and medium & small-sized data centers
Composite Anti-Static FloorComposite substrate with coated conductive layerCost-effective and easy installationOrdinary computer rooms and monitoring centers

3.3 By Anti-Static Performance

表格

CategorySurface Resistance RangeApplicable AmbienceApplication Characteristics
Static Dissipative Type10⁶~10⁹ΩMedium-high humidity (40%~60%RH)Mainstream choice for standard computer rooms balancing static protection and operational safety
Conductive Type10⁴~10⁶ΩLow humidity (<40%RH)Electronics manufacturing workshops and flammable & explosive working areas
Insulating Type>10¹²ΩSpecial insulation required sitesRarely used for regular computer rooms with customized design only

3.4 By Functional Characteristics

  1. Standard Type: Basic anti-static performance for conventional computer room deployment
  2. Ventilated Type: Opening ratio 5%~35% matching HVAC system to facilitate server heat dissipation
  3. Heavy-Duty Type: Single-point load ≥1500kg for areas deploying large server cabinets and UPS equipment
  4. Purified Type: Smooth dust-proof and antibacterial surface for clean computer rooms and medical equipment chambers

IV. KITOZER System Configuration List

4.1 Standard Configuration List for 600×600mm All-Steel Anti-Static Raised Floor

表格

No.Product NameModelSpecificationUnitRemarks
1All-Steel Anti-Static Floor PanelKITOZER-KG600600×600×35mm, all-steel + foamed cement core, HPL anti-static veneerPieceSurface resistance 10⁶~10⁹Ω, Class A fire rating
2Adjustable PedestalKITOZER-ZJ150Adjustable height 150~300mm, galvanized all steel, load ≥1000kgPieceComplete with base and height adjusting nut
3Stringer BeamKITOZER-HL600600mm length galvanized steel with stable conductivityPieceConnect pedestals to form grid framework
4Conductive Rubber StripKITOZER-JD0110mm width ×3mm thickness conductive rubberMeterInstalled at contact points between panels and beams
5Earthing Copper StripKITOZER-TD0420mm width ×0.2mm thickness pure copperMeterCross-section ≥4mm², overall earthing resistance ≤4Ω
6Earthing TerminalKITOZER-DZ01Copper fitting with built-in 1MΩ protective resistance boxPieceMinimum 1 terminal per 100㎡ floor area
7Ventilation FloorKITOZER-TF25600×600mm all-steel, 25% opening ratioPieceInstalled at air supply zones of air conditioning system
8Transition Ramp TrimKITOZER-XP600600mm length aluminum alloyPieceInstall at room entrance for equipment trolley access
9Wall Edge Closing StripKITOZER-SB01Aluminum alloy matched to floor elevationMeterGap treatment between floor and surrounding walls
10Installation AccessoriesKITOZER-AZ01Screws, buckles and gasketsSetFull set of auxiliary installation hardware

4.2 Customized Optional Configuration

表格

Custom CategoryOptional ProductsApplicable Scenarios
Height CustomizationKITOZER-ZJ300 (300~600mm adjustable height)Rooms requiring deep underfloor space for dense pipeline layout
Material UpgradeKITOZER-KS600 (Calcium Sulfate Core)Projects requiring superior environmental protection and dimensional stability
Functional UpgradeKITOZER-TF10/TF40 (10%/40% open area ventilation panel)High-density server areas with intensive heat dissipation demand
Surface Finish UpgradeKITOZER-KP600 (PVC Anti-static Veneer)Facilities requiring easy daily cleaning and high abrasion resistance

V. System Schematic Diagrams

5.1 Working Principle of Anti-Static Floor System

Electronics Equipment → Static Generation → Floor Anti-static Surface → Conductive Edge Strip → Stringer Beam → Pedestal → Earthing Copper Strip → Earthing Terminal → 1MΩ Protective Resistor Box → Building Earthing Grid → Earth

Auxiliary Supporting Functions:

Air Conditioning Unit → Cold Air → Perforated Vent Floor → Underfloor Plenum → Bottom Air Intake of IT Equipment → Heat Dissipation → Air Return

Cables → Concealed Underfloor Layout → Centralized Cable Management → Convenient Future Maintenance

5.2 Structural Installation Diagram

plaintext

┌─────────────────────────────────────┐
│ Floor Panel (600×600mm)            │
├─────────────────────────────────────┤
│ Conductive Rubber Strip             │
├─────────────────────────────────────┤
│ Stringer Beam (Grid Frame)          │
├─────────────────────────────────────┤
│ Adjustable Pedestal (150~600mm H)   │
├─────────────────────────────────────┤
│ Base Plate                          │
├─────────────────────────────────────┤
│ Leveled Base Concrete Floor         │
└─────────────────────────────────────┘

Side Elevation View:

plaintext

┌───────┐     ┌───────┐     ┌───────┐
│ Floor │─────│ Beam  │─────│ Floor │
└───┬───┘     └───┬───┘     └───┬───┘
    │             │             │
┌───┴───┐     ┌───┴───┐     ┌───┴───┐
│ Pedestal│───│Pedestal│───│Pedestal│
└───┬───┘     └───┬───┘     └───┬───┘
    │             │             │
┌───┴───┐     ┌───┴───┐     ┌───┴───┐
│ Base  │     │ Base  │     │ Base  │
└───┬───┘     └───┬───┘     └───┬───┘
    └─────────────┴─────────────┴── Base Floor

5.3 Conductive Network Connection Layout

Each floor panel forms electrical continuity with surrounding stringer beams via conductive edge strips; all beams connect through pedestals to centralized earthing copper strips to build an uninterrupted conductive network for uniform and rapid static electricity discharging without insulation breakpoints.

VI. KITOZER Technical Specifications

6.1 Core Technical Parameter Sheet

表格

Technical IndexKITOZER-KG600 All-Steel FloorKITOZER-KS600 Calcium Sulfate FloorApplicable Standard
Dimension600×600×35mm600×600×32mmGB/T 36340-2018
Surface Resistance10⁶~10⁹Ω(Dissipative)10⁶~10⁹Ω(Dissipative)GB/T 1410-2006
System Resistance10⁵~10⁹Ω10⁵~10⁹ΩGB/T 36340-2018
Concentrated Load≥1000kg per single point≥800kg per single pointSJ/T 10796-2021
Uniform Distributed Load≥1200kg/m²≥1000kg/m²SJ/T 10796-2021
Max Deflection Under Load≤2.0mm≤1.5mmSJ/T 10796-2021
Fire RatingClass A Non-combustibleClass A Non-combustibleGB 8624-2012
Steel ThicknessTop 0.8mm / Bottom 0.6mmTop 0.8mm / Bottom 0.6mmEnterprise Standard
Core FillerFoamed CementCalcium SulfateEnterprise Standard
Surface FinishHPL or PVC Anti-static LaminateHPL Anti-static LaminateEnterprise Standard
Operating Temperature-15℃~60℃-15℃~60℃Enterprise Standard
Humidity Adaptability10%~90%RH (Non-condensing)10%~90%RH (Non-condensing)Enterprise Standard
Design Service Life≥20 Years≥25 YearsEnterprise Standard

6.2 Support System Technical Parameters

表格

ComponentSpecificationApplicable Standard
Adjustable PedestalHeight 150~600mm, single load ≥1000kg, galvanized coating ≥8μmGB/T 13912-2020
Stringer Beam25×25mm cross-section, wall thickness 1.2mm, zinc coat ≥8μmGB/T 13912-2020
Earthing Copper Strip20mm width ×0.2mm thickness, copper purity ≥99.9%GB/T 5231-2021
Earthing TerminalCopper fitting, contact resistance ≤0.1ΩGB/T 13140-2021

6.3 Special Functional Parameters

表格

Function TypeTechnical DataApplicable Sites
Ventilated Floor5%~40% opening ratio, airflow ≥120m³/h per panelAir supply plenum for computer room HVAC
Anti-static PerformanceStatic electrification voltage<50V, charge decay time<0.5sHigh-density electronic equipment layout areas
Abrasion Resistance≥6000 cycles for HPL; ≥4000 cycles for PVC veneerHigh foot-traffic working zones
Environmental ProtectionFormaldehyde emission ≤0.08mg/m³ (Superior to E0 Grade)Computer rooms adjacent to office premises

VII. Application Scope

7.1 Core Application Fields

  1. Data Center & IDC Room: Cloud computing hub, carrier-grade IDC and financial data center requiring heavy load bearing and strict anti-static protection
  2. Enterprise Computer Room: In-house server, network and storage equipment room for stable IT operation guarantee
  3. Telecommunication Equipment Room: Telecom core equipment room and 5G central station to eliminate static interference on signal transmission
  4. Precision Instrument Lab: Semiconductor manufacturing workshop and metrology laboratory for delicate instrument protection against ESD damage
  5. Medical Equipment Chamber: CT/MRI diagnostic room and operating purification zone to secure precise operation of medical electronic devices

7.2 Extended Application Scenarios

表格

Application SceneKey RequirementRecommended Product
Industrial Control CenterAnti-static and anti-interference for harsh industrial environmentKITOZER-KG600 All-Steel Floor
Radio & TV Broadcasting CenterAnti-static, sound insulation and shock absorptionKITOZER-KS600 Calcium Sulfate Floor
Power Dispatching CenterHigh load capacity, fire & moisture resistanceKITOZER-KG600 All-Steel Floor
Military Command CenterAnti-static and anti-electromagnetic interferenceKITOZER-KG600 + Optional Shielding Layer
Clean Production WorkshopDustproof, anti-static and chemical resistanceKITOZER Aluminum Alloy Floor

7.3 Unsuitable Working Conditions

  1. Permanently waterlogged environments (custom waterproof treatment required separately)
  2. Severe strong chemical corrosion sites (special anti-corrosion coating customization needed)
  3. Extreme ambient temperature over 60℃ or below -15℃ (custom temperature-resistant products available on request)

VIII. KITOZER Brand Competitive Advantages

8.1 Core Technical Superiority

  1. Stable Static Control: Imported conductive raw materials maintain steady surface resistance 10⁶~10⁹Ω irrespective of ambient humidity; static discharge time<0.1s exceeding national regulatory criteria.
  2. Outstanding Load Capacity: All-steel construction delivers single-point concentrated load ≥1000kg and uniform load ≥1200kg/m² to bear heavy server racks without long-term deformation.
  3. Fire Safety Assurance: Class A non-combustible core material certified per GB 8624-2012 to inhibit fire spreading and improve computer room safety.
  4. Extended Service Life: Hot-dip galvanized all-steel components resist rust and abrasion with minimum 20-year service lifespan above industry average level.

8.2 Integrated System Advantages

  1. Modular Standardization: Uniform 600×600mm panel size for rapid installation, removal and component replacement cutting later maintenance cost.
  2. Flexible Height Adjustment: 150~600mm adjustable pedestal adapting diversified underfloor cabling and layout design demands.
  3. Complete Conductive Network: Continuous full-path grounding with overall earthing resistance ≤4Ω ensuring reliable static dissipation.
  4. Diversified Customization: Optional ventilation, heavy-duty and purification specifications to satisfy customized project requirements.

8.3 After-Sales & Service Superiority

  1. Free Professional Layout Design: Technical team provides tailor-made floor layout scheme based on room dimension and equipment distribution.
  2. Standardized Professional Installation: Certified construction team with laser leveling tools; full anti-static performance inspection upon project completion.
  3. Comprehensive Warranty: 5-year product warranty plus lifetime technical maintenance with 24-hour customer service response.
  4. Custom Production Capability: Non-standard size, elevation and functional floor customization per unique client specifications.

IX. Bid Tender Specification Parameters (For Tender Document Formulation)

9.1 Core Bid Technical Specifications

  1. Basic Requirements
  • Standard dimension: 600×600mm; thickness ≥35mm for all-steel floor, ≥32mm for calcium sulfate floor
  • Brand Qualification: KITOZER with original manufacturer authorization document submission required
  • Compliance Certification: Conform to GB 50174-2017, GB/T 36340-2018, SJ/T 10796-2021 and relevant domestic standards
  1. Anti-static Index
  • Surface resistance range:10⁶~10⁹Ω (static dissipative type, tested per GB/T 1410-2006)
  • Whole system resistance:10⁵~10⁹Ω per GB/T 36340-2018 testing standard
  • Static electrification voltage<50V, charge decay time<0.5s
  1. Mechanical Performance
  • Concentrated load ≥1000kg with post-test deflection ≤2.0mm
  • Uniform distributed load ≥1200kg/m² without permanent deformation after load testing
  • Abrasion resistance:≥6000 wear cycles for HPL, ≥4000 cycles for PVC veneer
  1. Safety Index
  • Fire performance: Class A non-combustible complying with GB 8624-2012
  • Environmental index: Formaldehyde release ≤0.08mg/m³ superior to E0 standard GB 18580-2017
  • Anti-corrosion: Pass 48-hour salt spray test without obvious surface corrosion

9.2 Supporting System Bid Specifications

  1. Pedestal: Hot galvanized all steel, adjustable height 150~600mm, single load ≥1000kg, zinc coating ≥8μm thickness
  2. Stringer Beam: Galvanized steel, cross-section ≥25×25mm, wall thickness ≥1.2mm with qualified electrical conductivity
  3. Grounding System
  • Copper earthing strip: Cross-sectional area ≥4mm², copper conductivity ≥99.9%
  • Earthing terminal: Copper component with contact resistance ≤0.1Ω, minimum one terminal every 100㎡ floor space
  • Protective resistance box equipped with 1MΩ±10% fixed current-limiting resistor to prevent surge current hazards

9.3 Acceptance Inspection Criteria

  1. Installation Precision: Floor flatness tolerance ≤2.0mm per 2m measuring span, panel gap ≤0.5mm
  2. Anti-static Test: Minimum five random testing points with all measured values complying with specified resistance range via professional resistance tester
  3. Load Sampling Test: Test under 1.2 times rated load without permanent deformation
  4. Earthing Test: Total system earthing resistance ≤4Ω verified by professional earth resistance tester

X. Targeted Project Solutions

10.1 Large-Scale Data Center Solution

10.1.1 Project Overview

High-load, stable anti-static and easy-maintenance raised floor solution designed for dense server deployment and large-volume underfloor cabling layout.

10.1.2 Core Configuration

  • Floor Type: KITOZER-KG600 35mm thick all-steel anti-static floor
  • Support Height: 300~400mm adjustable pedestal for abundant underfloor pipeline space
  • Special Fitting: 25% open-area ventilation floor installed 1 piece per 4㎡ for even air distribution
  • Grounding Layout: Denser copper earthing strips with one terminal per 50㎡ for accelerated static discharging

10.1.3 Construction Key Points

  1. Base Floor Treatment: Leveling and moisture-proof treatment to control base flatness ≤2.0mm/2m
  2. Pedestal Positioning: Laser level guided installation to guarantee consistent horizontal elevation
  3. Beam Installation: Form standard 600×600mm rigid grid framework with level alignment
  4. Floor Laying: Panel installation starting from room center toward surrounding walls with rubber hammer fitting for uniform joint gap
  5. Grounding Connection: Complete electrical continuity inspection with final earthing resistance ≤4Ω acceptance requirement

10.2 Medium & Small-Sized Computer Room Solution

10.2.1 Project Overview

Cost-optimized easy-installation floor solution satisfying regular anti-static and basic cabling demand for SME server premises.

10.2.2 Core Configuration

  • Floor Selection: KITOZER-KS600 32mm calcium sulfate anti-static floor
  • Pedestal Height:150~200mm adjustable for basic underfloor wiring space
  • Auxiliary Parts: Standard panels plus partial 10% opening ventilation floor matching small-capacity air conditioning
  • Grounding Layout: Standard specification with one earthing terminal per 100㎡ floor space

10.2.3 Construction Highlights

  1. Simplified Base Treatment: Basic ground leveling only; calcium sulfate floor’s inherent moisture resistance eliminates extra waterproof construction
  2. Fast Modular Installation: 50% higher construction efficiency compared to traditional floor products
  3. Convenient Later Maintenance: Single-panel quick detachment for underfloor pipeline overhaul

10.3 Special Environment Customized Solutions

10.3.3 Cleanroom Computer Room

  • Floor Option: KITOZER aluminum alloy anti-static floor with seamless gap sealing preventing underfloor dust accumulation

10.3.4 Heavy-Duty Equipment Room

  • Floor Option: Custom thickened 40mm KITOZER-KG600 all-steel heavy-duty floor
  • Reinforced Support: Denser pedestal layout with four supports per single floor panel and pedestal spacing ≤300mm for ultra-high load capacity

XI. Practical Engineering Application Cases

11.1 Case 1: South China Cloud Computing Data Center

11.1.1 Project Profile

  • Scale: 1200㎡ computer room accommodating over 1000 server units
  • Demand: High load capacity, reliable anti-static performance, efficient ventilation and easy daily maintenance
  • Solution: KITOZER-KG600 all-steel floor system with 350mm elevation and 25% opening ventilation panels

11.1.2 Operational Outcome

  1. Load Performance: Actual single-point bearing up to 1200kg fully compatible with heavy server cabinet deployment
  2. Static Protection: Stable surface resistance 10⁷~10⁸Ω with static dissipation<0.1s completely eliminating ESD equipment failures
  3. HVAC Optimization: Uniform underfloor air supply stabilizes indoor temperature at 22±1℃ reducing overall air-conditioning power consumption by 15%
  4. Easy Maintenance: Single panel removal within 2 minutes greatly improving pipeline troubleshooting efficiency

11.2 Case 2: Head Office Financial Data Center of Domestic Bank

11.2.1 Project Profile

  • Scale:800㎡ core financial data room for core business server and storage equipment deployment
  • Demand: High safety standard, long-term stability, long service life complying with financial industry construction specifications
  • Solution: KITOZER-KG600 all-steel floor with 400mm overhead clearance, Class A fireproof and E0-level environmental protection

11.2.2 Project Effect

  1. Safety Performance: Class A non-combustible certification passed strict financial industry acceptance inspection
  2. Stable Operation: Five-year fault-free running with unchanged anti-static parameters and zero static-caused equipment faults
  3. Regulatory Compliance: Fully meets Grade A standard of GB 50174-2017 Data Center Design Code and passed official bank acceptance check
  4. Cost Saving: ≥20-year design service life reduces long-term facility renovation investment

11.3 Case 3: Hospital MRI Medical Equipment Room

11.3.1 Project Profile

  • Scale:150㎡ diagnostic room equipped with MRI and CT precision medical devices
  • Demand: Anti-static, low-noise, chemical-resistant flooring adapting medical disinfection environment
  • Solution: KITOZER-KS600 calcium sulfate anti-static floor with 200mm pedestal height and HPL surface veneer

11.3.2 Application Result

  1. Static Control: Steady 10⁶~10⁸Ω surface resistance prevents static interference impacting medical scanning precision
  2. Noise Reduction: Calcium sulfate core’s sound-absorbing property cuts indoor equipment running noise by 20%
  3. Eco-friendly Property: Formaldehyde emission below E0 standard satisfying strict hospital environmental requirements
  4. Chemical Resistance: HPL veneer withstands regular medical disinfectant wiping without surface damage

XII. Search Keywords & SEO Tags

12.1 Core Search Keywords

Computer room anti-static floor, KITOZER anti-static raised floor, data center raised access floor, all-steel anti-static floor, overhead computer room floor, anti-static flooring system, GB 50174 compliant anti-static floor, anti-static floor bidding specification

12.2 SEO Optimized Long-Tail Keywords

Computer room anti-static floor construction solution, KITOZER brand floor technical datasheet, all-steel raised floor installation guide, data center floor type selection, underfloor grounding system design, anti-static performance testing standard, engineering application case of raised access floor

12.3 Hashtags

#ComputerRoomDecoration #AntiStaticFloor #KITOZER #DataCenter #ITRoomSolution #AllSteelRaisedFloor #OverheadFloor #ESDProtection #RoomDesign #GB50174