KITOZER
KITOZER

KITOZER Row-Based Air Conditioning Solution for Computer Rooms

1. System Overview

The KITOZER row-based air conditioning system is a high-efficiency cooling solution tailor-made for modern data centers and computer rooms. Adopting row-level cooling concept, the air conditioning units are installed side by side with server cabinets to implement close-range cooling, thoroughly eliminating the efficiency bottlenecks of traditional computer room air conditioners featuring long-distance air supply and cold-hot air mixing.

Equipped with core characteristics including high sensible heat ratio, large air volume, precise temperature control and intelligent linkage, the system meets diverse cooling requirements from small and medium-sized computer rooms to large cloud computing data centers. It is particularly applicable to high-density server deployment scenarios, effectively reducing PUE and improving the overall energy efficiency of computer rooms.

Delivering cold air horizontally to the air inlet side of cabinets and immediately absorbing hot air exhausted from the rear of cabinets, the system forms a closed cold and hot air passage circulation. It significantly boosts cooling efficiency, reduces energy waste, and serves as critical infrastructure for green and low-carbon operation of data centers.

2. System Composition

The KITOZER row-based air conditioning system consists of the following core components:

System ComponentMain CompositionFunction Description
Core Refrigeration UnitDC inverter scroll compressor, high-efficiency evaporator, condenser, electronic expansion valveCompletes the full refrigeration cycle of refrigerant compression, condensation, expansion and evaporation to deliver stable cooling capacity output
Air Handling UnitEC energy-saving fan, medium-efficiency filter, humidifier, electric heaterRealizes air volume adjustment, air purification, humidity control and auxiliary heating to stabilize computer room environmental parameters
Intelligent Control UnitColor touchscreen controller, temperature and humidity sensors, pressure sensors, communication modulePrecisely controls temperature and humidity (±0.5℃/±5%RH), supports remote monitoring and intelligent linkage, and provides fault early warning and diagnosis functions
Auxiliary SystemRefrigeration pipelines, thermal insulation layer, drainage system, power distribution unitEnsures stable system operation, prevents condensate leakage, and provides safe and reliable power supply
Monitoring & Management PlatformCentral monitoring software, data acquisition gateway, mobile APPEnables centralized management of multiple units, energy consumption analysis, remote control and report generation, and supports docking with data center management systems

3. System Classification

3.1 Classification by Refrigeration Mode

TypeCore FeaturesApplicable Scenarios
Air-Cooled Direct Expansion TypeBuilt-in refrigeration system; outdoor and indoor units connected via copper tubes with simple installation; no dedicated chilled water system requiredSmall and medium-sized computer rooms, sites without centralized refrigeration systems, computer room renovation projects
Water/Chilled Water-Cooled TypeAdopts external chilled water system as cold source with high energy efficiency ratio, suitable for high cooling capacity demandsLarge-scale data centers, high-density computer rooms, projects with strict PUE requirements
Pump-Assisted Free Cooling TypeIntegrates fluorine pump energy-saving technology; switches to free cooling mode in low-temperature environments to greatly reduce energy consumptionData centers in cold climate regions pursuing low PUE throughout the year
Dual-Cold-Source TypeEquipped with both direct expansion and chilled water refrigeration modes for mutual backup with ultra-high reliabilityMission-critical business data centers in finance, telecommunications and other industries, Class A computer rooms
computer room in row air conditioning solution (8)

3.2 Classification by Air Supply Mode

1. Front Air Supply & Rear Air Return Type: Standard configuration. Cold air is delivered from the front of the unit and hot air is sucked from the rear, applicable to computer rooms with closed cold and hot aisle layout.

2. Bottom Air Supply & Top Air Return Type: Cold air is delivered from the unit bottom and hot air is sucked from the top, suitable for special computer room layouts and raised floor environments.

3. Dual-Side Air Supply Type: Delivers air to cabinets on both sides simultaneously, applicable to large computer room aisles and high-density cabinet deployment scenarios.

3.3 Classification by Capacity Specification

• Small Row-Based Air Conditioner: Cooling capacity of 12-25kW, applicable to small and medium-sized computer rooms and edge computing nodes

• Medium Row-Based Air Conditioner: Cooling capacity of 30-45kW, applicable to standard data center computer rooms and cloud computing nodes

• Large Row-Based Air Conditioner: Cooling capacity of 50-65kW, applicable to high-density server clusters and AI computing power centers

4. System Configuration List (Brand: KITOZER)

4.1 Basic Configuration List (Air-Cooled Direct Expansion Type, 25kW)

No.Equipment NameModelQuantitySpecification & Parameters
1Row-Based Air Conditioner Indoor UnitKITOZER-KR-251 SetCooling capacity: 25kW, sensible heat ratio ≥0.97, air volume: 8000m³/h, 2 EC fans, 380V/3P/50Hz
2Row-Based Air Conditioner Outdoor UnitKITOZER-KR-25-O1 SetMatched with indoor unit cooling capacity, air-cooled condenser, IP54 protection grade, 380V/3P/50Hz
3Intelligent ControllerKITOZER-CC-011 SetColor touch screen, RS485 communication supported, Modbus protocol, temperature & humidity control accuracy: ±0.5℃/±5%RH
4Medium-Efficiency FilterKITOZER-F-022 PcsG4 filtration efficiency, matched air volume, washable and reusable
5HumidifierKITOZER-H-031 PcElectrode humidification, humidification capacity: 3kg/h, automatic sewage discharge function
6Electric HeaterKITOZER-EH-021 PcHeating power: 3kW, graded control, dry-burning protection
7Refrigeration Pipeline KitKITOZER-PK-251 SetIncluding copper tubes, thermal insulation layers, valves, joints, etc., adapted to 25kW units
8Installation AccessoriesKITOZER-MT-011 SetIncluding fixed brackets, shock-absorbing pads, cable trays, etc.
9Monitoring ModuleKITOZER-SM-011 PcSupports remote monitoring, data acquisition and fault early warning

4.2 Enhanced Configuration List (Chilled Water Type, 45kW)

No.Equipment NameModelQuantitySpecification & Parameters
1Row-Based Air Conditioner Indoor UnitKITOZER-KW-451 SetCooling capacity: 45kW, sensible heat ratio ≥0.97, air volume: 10000m³/h, dual EC fan system
2Chilled Water Interface ModuleKITOZER-WM-011 SetIncluding electric two-way valve, filter, pressure gauge, temperature sensor
3Intelligent ControllerKITOZER-CC-021 PcSupports chilled water flow control and linkage with chilled water system, equipped with color touch screen
4Medium-Efficiency FilterKITOZER-F-042 PcsG4 filtration efficiency, high-air-volume design, washable and reusable
5HumidifierKITOZER-H-051 PcElectrode humidification, humidification capacity: 5kg/h, automatic water level control
6Electric HeaterKITOZER-EH-031 PcHeating power: 6kW, multi-stage control, overheating protection
7Installation AccessoriesKITOZER-MT-021 SetIncluding heavy-duty brackets, shock absorption system, cable management components
8Advanced Monitoring ModuleKITOZER-SM-021 PcSupports energy consumption analysis, fault diagnosis and remote upgrade, Modbus TCP protocol
9Redundant Power ModuleKITOZER-PS-011 PcDual power input, automatic switching, ensuring uninterrupted system operation

4.3 Optional Accessories List

Accessory NameModelFunction Description
Fluorine Pump Energy-Saving ModuleKITOZER-FP-01Switches to free cooling mode in low-temperature environments, achieving 30%-40% energy saving
Air Distribution Optimization KitKITOZER-AF-01Customized air duct design improves cooling efficiency and reduces temperature difference between cabinets
High-Efficiency Upgrade PackageKITOZER-EE-01Upgrades to DC inverter fans and compressors to improve system energy efficiency ratio
Water Leakage Detection SystemKITOZER-LD-01Real-time condensate leakage monitoring with sound-light alarm and automatic shutdown protection
Remote Operation & Maintenance Service PackageKITOZER-RM-01Provides 7×24-hour remote monitoring and operation & maintenance support
computer room in row air conditioning solution (7)

5. System Schematic Diagram & Working Principle

5.1 Schematic Diagram of Air-Cooled Direct Expansion Row-Based Air Conditioning System

[Outdoor Environment] → [Condenser] → [Electronic Expansion Valve] → [Evaporator] → [Compressor] → [Condenser]

↑ ↓ ↓ ↓ ↓ ↑

[Fan] ← [Hot Air Intake] ← [Server Cabinet] ← [Cold Air Supply] ← [Fan] ← [Evaporator]

Working Principle

1. The compressor compresses low-temperature and low-pressure refrigerant gas into high-temperature and high-pressure gas.

2. The high-temperature and high-pressure gas enters the outdoor condenser and is cooled into high-pressure liquid by the fan.

3. The high-pressure liquid is throttled and depressurized by the electronic expansion valve to form low-temperature and low-pressure gas-liquid mixture.

4. The low-temperature and low-pressure refrigerant enters the indoor evaporator, absorbs heat from the hot air in the computer room, and evaporates into gas.

5. The evaporator fan delivers cooled cold air to cabinets and sucks hot air for cooling circulation simultaneously.

6. The gaseous refrigerant re-enters the compressor to complete one refrigeration cycle.

5.2 Schematic Diagram of Chilled Water Row-Based Air Conditioning System

[Chilled Water System] → [Electric Two-Way Valve] → [Water-Side Heat Exchanger] → [Return Water] → [Chilled Water System]

↑ ↓ ↓ ↓ ↑

[Fan] ← [Hot Air Intake] ← [Server Cabinet] ← [Cold Air Supply] ← [Fan] ← [Air-Side Heat Exchanger]

Working Principle

1. Chilled water flows from the external chilled water system into the water-side heat exchanger.

2. The indoor fan sucks hot air from the computer room, which undergoes heat exchange via the air-side heat exchanger and is cooled into cold air.

3. The cold air is delivered to cabinets to cool down servers.

4. The heated water after heat exchange returns to the chilled water system for re-cooling.

5. The electric two-way valve automatically adjusts chilled water flow according to computer room temperature to maintain stable indoor temperature.

5.3 Schematic Diagram of Intelligent Control System

[Temperature & Humidity Sensor] → [Data Acquisition Module] → [Intelligent Controller] → [Actuator] → [Air Conditioning Equipment]

↑ ↑ ↑ ↑ ↓

[Pressure Sensor] → [Flow Sensor] → [Communication Module] → [Remote Monitoring Platform] → [Fault Alarm]

Control Logic

1. Various sensors collect real-time computer room environmental parameters and equipment operating status.

2. The data acquisition module converts sensor signals into digital signals and transmits them to the intelligent controller.

3. The intelligent controller sends control instructions to actuators based on preset temperature and humidity parameters and control strategies.

4. Actuators adjust the operating status of compressors, fans, humidifiers, heaters and other equipment.

5. The communication module uploads operating data to the remote monitoring platform and receives remote control instructions simultaneously.

6. The system triggers fault alarms immediately and activates corresponding protective measures in case of abnormalities.

computer room in row air conditioning solution (6)

6. Product Technical Parameters

6.1 Air-Cooled Direct Expansion Row-Based Air Conditioner (KITOZER-KR Series)

Parameter ItemKR-25KR-45KR-65
Cooling Capacity25kW45kW65kW
Sensible Heat Ratio≥0.97≥0.97≥0.97
Air Volume8000m³/h10000m³/h12000m³/h
Compressor TypeDC Inverter Scroll CompressorDual DC Inverter Scroll CompressorsTriple DC Inverter Scroll Compressors
Fan Type2× EC Energy-Saving Fans3× EC Energy-Saving Fans4× EC Energy-Saving Fans
Temperature Control Accuracy±0.5℃±0.5℃±0.5℃
Humidity Control Accuracy±5%RH±5%RH±5%RH
Humidification Capacity3kg/h5kg/h8kg/h
Heating Power3kW6kW9kW
Power Specification380V/3P/50Hz380V/3P/50Hz380V/3P/50Hz
Noise Level≤55dB≤58dB≤60dB
Dimension (W×D×H)600×1200×2000mm600×1200×2200mm600×1200×2400mm
Weight350kg480kg620kg

6.2 Chilled Water Row-Based Air Conditioner (KITOZER-KW Series)

Parameter ItemKW-25KW-45KW-65
Cooling Capacity25kW45kW65kW
Sensible Heat Ratio≥0.97≥0.97≥0.97
Air Volume8000m³/h10000m³/h12000m³/h
Water-Side Heat ExchangerHigh-Efficiency Plate Heat ExchangerHigh-Efficiency Plate Heat ExchangerHigh-Efficiency Shell & Tube Heat Exchanger
Chilled Water Temperature12-18℃12-18℃12-18℃
Water Flow Rate4.2m³/h7.5m³/h10.8m³/h
Fan Type2× EC Energy-Saving Fans3× EC Energy-Saving Fans4× EC Energy-Saving Fans
Temperature Control Accuracy±0.5℃±0.5℃±0.5℃
Humidity Control Accuracy±5%RH±5%RH±5%RH
Humidification Capacity3kg/h5kg/h8kg/h
Heating Power3kW6kW9kW
Power Specification380V/3P/50Hz380V/3P/50Hz380V/3P/50Hz
Noise Level≤54dB≤57dB≤59dB
Dimension (W×D×H)600×1200×2000mm600×1200×2200mm600×1200×2400mm
Weight320kg450kg580kg

6.3 Intelligent Control System Technical Parameters

Parameter ItemTechnical Specification
Control ModeMicroprocessor intelligent control, supporting automatic/manual/remote control modes
Communication InterfaceRS485, Modbus RTU/TCP, SNMP protocol supported
Data StorageBuilt-in memory, storing over 1 year of operating data
Display Interface7-inch color touch screen, 800×480 resolution
Control AccuracyTemperature: ±0.5℃, Humidity: ±5%RH
Protection FunctionsOvervoltage, undervoltage, overcurrent, overheating, phase loss and water leakage protection
Linkage FunctionsSupports linkage with UPS, computer room monitoring system and fire protection system
Remote ManagementSupports remote access and control via web browser and mobile APP
computer room in row air conditioning solution (5)

7. Product Application Scope

7.1 Data Center Field

• Cloud Computing Data Centers: Large-scale cloud computing centers and supercomputing centers, supporting high-density server deployment and PUE reduction

• Financial Data Centers: Core computer rooms of banks, securities, insurance and other financial institutions requiring high reliability and precise temperature control

• Telecommunications Data Centers: Core computer rooms and edge computing nodes of communication operators, meeting 7×24-hour uninterrupted operation requirements

• Enterprise Data Centers: Private cloud and hybrid cloud data centers of large enterprises, supporting rapid business expansion

7.2 Computer Room & IT Infrastructure Field

• IDC Hosting Computer Rooms: Third-party data center hosting services, meeting customized cooling needs of different customers

• AI Computing Power Centers: AI training and inference computer rooms, supporting high-density GPU deployment and solving high heat generation problems

• Edge Computing Nodes: 5G base station computer rooms and IoT data collection centers, meeting miniaturized and high-efficiency cooling requirements

• Modular Data Centers: Micro-module computer rooms and container data centers, supporting rapid deployment and flexible expansion

7.3 Special Application Scenarios

• Medical Data Centers: Hospital HIS and PACS system computer rooms requiring high reliability and air cleanliness

• Scientific Research Computing Centers: Supercomputer rooms of universities and research institutes, meeting high-precision computing environment requirements

• Industrial Control Computer Rooms: Intelligent manufacturing and industrial internet control centers, adapting to harsh industrial environment requirements

• Military Command Centers: Military communication and command & control system computer rooms, meeting high security and anti-interference requirements

computer room in row air conditioning solution (4)

8. Product Advantages

8.1 High Energy Efficiency & Low PUE

• Close-Range Cooling: Installed side by side with cabinets, reducing air supply distance by 80%, minimizing cold loss and increasing cooling efficiency by over 30%

• High Sensible Heat Ratio Design: Sensible heat ratio ≥0.97, optimized for high sensible heat load characteristics of computer rooms to avoid latent heat waste

• EC Energy-Saving Fans: Over 40% energy saving compared with traditional fans, with stepless speed regulation to match variable load demands

• Inverter Technology Application: Three-way linkage regulation of DC inverter compressor, electronic expansion valve and EC fan, improving partial load energy efficiency ratio by 50%

• Free Cooling Compatibility: Pump-assisted free cooling models switch to free cooling mode in low-temperature environments, saving over 38% energy

8.2 Precise Temperature Control & Stable Equipment Operation

• Temperature control accuracy of ±0.5℃ and humidity control accuracy of ±5%RH, ensuring servers operate in the optimal environmental parameter range

• Horizontal air supply design ensures uniform cabinet inlet air temperature with inter-cabinet temperature difference <2℃, eliminating local hot spots

• Rapid response capability: The system adjusts output within 1 minute under load changes to adapt to dynamic server load fluctuations

• Full-time stable operation: Compliant with ASHRAE A3 high-temperature environment, stably operating at 35℃ inlet air temperature

8.3 Intelligent Management & Simplified O&M

• Intelligent control system: 7-inch color touch screen with one-click operation and fault diagnosis functions

• Remote monitoring: Supports web and APP remote access for real-time monitoring of computer room environment and equipment status

• Energy consumption analysis: Precisely counts energy consumption data and provides energy-saving suggestions to facilitate green computer room construction

• Fault early warning mechanism: Predicts potential faults in advance to reduce downtime risks and improve system availability

• Modular design: Componentized structure enables convenient maintenance without full-unit shutdown for part replacement

8.4 High Reliability & Business Continuity

• Redundant design: Supports N+1 and 2N redundant configurations to avoid single-point failures affecting the overall system

• Multiple protection functions: Comprehensive protection against overvoltage, undervoltage, overcurrent, overheating, phase loss and water leakage to extend equipment service life

• Wide voltage adaptability: Tolerates 380V±15% voltage fluctuations, suitable for complex power grid environments

• IP54 protection grade: Outdoor units with IP54 protection grade adapt to harsh weather conditions

• Long service life design: Key components service life ≥80,000 hours, MTBF (Mean Time Between Failures) ≥100,000 hours

8.5 Flexible Adaptability & Diverse Demand Support

• Multiple refrigeration modes: Optional air-cooled, water-cooled, pump-assisted free cooling and dual-cold-source solutions

• Flexible air supply modes: Front-supply rear-return, bottom-supply top-return and dual-side air supply adapt to various computer room layouts

• Full capacity coverage: 12-65kW full-series products meeting demands from edge computing to large-scale data centers

• Rapid deployment: Standardized design cuts installation time by 50% and reduces business impact

• Seamless expansion: Supports parallel operation of multiple units to adapt to increasing cooling demands with business growth

computer room in row air conditioning solution (3)

9. Bid Parameter Specifications for Bidding

9.1 Basic Performance Requirements

1. Cooling capacity: ≥45kW (specify as required), sensible heat ratio ≥0.97, full-load operation available at 35℃ inlet air temperature

2. Air volume: ≥10000m³/h, equipped with EC energy-saving fans with stepless speed regulation and fan efficiency ≥85%

3. Temperature control accuracy: Return air temperature control accuracy ±0.5℃, supply air temperature range: 14℃-27℃

4. Humidity control accuracy: Relative humidity control range: 30%-70%RH, control accuracy ±5%RH, no condensation

5. Noise level: ≤58dB (measured 1 meter away from the unit), compliant with computer room noise standards

9.2 Core Component Technical Requirements

1. Compressor: DC inverter scroll compressor (Copeland or equivalent well-known brand) with overload and overheating protection functions

2. Expansion Valve: Electronic expansion valve supporting precise flow control with response time ≤1 second

3. Fan: EC centrifugal fan with IP54 protection grade and 0-100% continuous wind speed regulation

4. Controller: 7-inch or larger color touch screen with Chinese interface, data storage and export functions

5. Filter: G4 medium-efficiency filter, washable and reusable with replacement cycle ≥6 months

9.3 Intelligent Control & Management Requirements

1. Communication Interface: Equipped with RS485 interface, supporting Modbus RTU/TCP protocol, optional SNMP module

2. Monitoring Function: Real-time monitoring of temperature, humidity, pressure, flow, energy consumption and other parameters with trend analysis function

3. Linkage Function: Supports linkage with UPS, fire protection system and access control system for integrated management

4. Remote Management: Supports remote access via web browser and mobile APP for remote control and fault diagnosis

5. Fault Early Warning: Fault prediction function with 72-hour advance warning of potential faults to reduce downtime risks

9.4 Reliability & Safety Requirements

1. Protection Grade: Indoor unit ≥IP20, outdoor unit ≥IP54

2. Protection Functions: Comprehensive protection against overvoltage, undervoltage, overcurrent, overheating, phase loss, water cut-off and water leakage

3. Redundant Design: Supports N+1 redundant configuration; single-unit failure does not affect overall system operation

4. Power Adaptability: Voltage adaptation range 380V±15%, frequency 50Hz±2%, lightning protection function equipped

5. Environmental Protection Requirements: Adopts R410A environmentally friendly refrigerant, compliant with EU RoHS and WEEE directives

9.5 After-Sales Service Requirements

1. Warranty Period: ≥3-year full-unit warranty, ≥5-year warranty for core components (compressors, controllers)

2. Service Response: 7×24-hour technical support, 4-hour response and 24-hour on-site arrival (first-tier cities)

3. Spare Parts Guarantee: Domestic spare parts center available; common spare parts delivered within 48 hours, special spare parts within 72 hours

4. O&M Training: Free system operation and maintenance training to ensure users master basic O&M skills

5. Regular Inspection: 2 free annual inspections within the warranty period to ensure stable system operation

10. Customized Solutions

10.1 Small & Medium-Sized Computer Room Solution (100-300㎡)

Solution Overview

Adopts air-cooled direct expansion row-based air conditioning system with N+1 redundant configuration and intelligent monitoring platform, balancing economy and reliability to meet cooling demands of small and medium-sized computer rooms.

Core Configuration

• 3 sets of KITOZER-KR-25 row-based air conditioners (2 working + 1 standby)

• 1 set of KITOZER intelligent monitoring platform

• 1 set of cold & hot aisle closure system

• 1 set of redundant power distribution unit

Solution Advantages

• Low investment cost and short deployment cycle, suitable for small and medium-sized enterprises with limited budgets

• Air-cooled direct expansion design requires no dedicated chilled water system with simple maintenance

• N+1 redundant configuration ensures business continuity and avoids single-point failures

• Intelligent monitoring platform enables remote management and reduces O&M costs

10.2 Large-Scale Data Center Solution (500-2000㎡)

Solution Overview

Adopts chilled water row-based air conditioning system with 2N redundant configuration, equipped with fluorine pump free cooling energy-saving module and intelligent management platform, meeting high-density, high-reliability and low-PUE cooling requirements of large-scale data centers.

Core Configuration

• 10 sets of KITOZER-KW-45 row-based air conditioners (5 working + 5 standby)

• 10 sets of KITOZER fluorine pump free cooling energy-saving modules

• 1 set of KITOZER intelligent management platform

• 1 set of precision power distribution system

• 5 sets of closed cold aisle systems

Solution Advantages

• Chilled water design features high energy efficiency ratio, suitable for high cooling capacity demands, reducing PUE below 1.2

• Fluorine pump free cooling technology fully utilizes natural cold sources with over 38% energy saving

• 2N redundant configuration meets Class A computer room standards and ensures zero business interruption

• Intelligent management platform realizes energy consumption analysis, fault early warning and remote O&M to improve management efficiency

10.3 Modular Data Center Solution

Solution Overview

Integrates integrated row-based air conditioning modules with cabinets, UPS, power distribution and monitoring systems to form a complete micro-module data center solution, supporting rapid deployment and flexible expansion.

Core Configuration

• KITOZER integrated row-based air conditioning module (integrated refrigeration, control and monitoring functions)

• Standard 19-inch 42U server cabinets

• Rack-mounted UPS and battery pack

• Intelligent Power Distribution Unit (PDU)

• Environmental monitoring system

Solution Advantages

• Integrated design with factory prefabrication cuts on-site installation time by 80%

• Plug-and-play and rapid deployment meets rapid business launch demands

• Flexible on-demand expansion avoids resource waste

• High integration reduces computer room floor area and improves space utilization

10.4 AI Computing Power Center Solution

Solution Overview

Tailored for high-density GPU-deployed AI computer rooms, this solution adopts dual-side air supply row-based air conditioning system with high-temperature cooling technology and intelligent air distribution management system to solve high heat generation problems and ensure stable AI computing operation.

Core Configuration

• KITOZER 65kW dual-side air supply row-based air conditioner units

• High-temperature cooling module (supporting 35℃ inlet air temperature)

• Intelligent air distribution management system

• Micro-environment monitoring system (cabinet-level temperature & humidity monitoring)

• Redundant power system

Solution Advantages

• Dual-side air supply meets high air volume demands of GPU cabinets with inter-cabinet temperature difference <2℃

• High-temperature cooling technology adapts to ASHRAE A3 environment and improves chilled water system energy efficiency

• Micro-environment monitoring tracks real-time temperature status of each cabinet for precise cooling capacity adjustment

• Redundant design ensures uninterrupted AI training tasks and improves computing efficiency

11. Application Cases

11.1 Case 1: Cloud Computing Data Center Project

Project Background

A leading domestic cloud computing service provider built a new large-scale data center with 5,000 servers planned for deployment, single cabinet power density of 8kW, required PUE <1.3 and 7×24-hour uninterrupted operation.

Adopted Solution

Adopted KITOZER-KW-45 chilled water row-based air conditioning system with 60 units (50 working + 10 standby), equipped with fluorine pump free cooling energy-saving modules and intelligent management platform, adopting closed cold aisle design.

Implementation Effects

• Computer room PUE reduced to 1.25, saving approximately 8 million RMB in annual electricity costs

• Cabinet inlet air temperature controlled at 24±1℃ with temperature difference <2℃, ensuring stable server operation

• Fluorine pump free cooling system operates in winter and transition seasons with 38% energy saving rate

• Intelligent management platform realizes remote monitoring and fault early warning, reducing O&M manpower by 50%

11.2 Case 2: Core Computer Room Renovation Project for Financial Institution

Project Background

A large state-owned bank’s original computer room adopted traditional room-level air conditioners, suffering from local hot spots and high server failure rates. The bank planned to renovate to row-based air conditioning system without affecting ongoing business and improve operational reliability.

Adopted Solution

Adopted KITOZER-KR-25 air-cooled direct expansion row-based air conditioning system with 12 units (10 working + 2 standby), implemented in phased online renovation to avoid business interruption.

Implementation Effects

• Local hot spot problems completely eliminated, computer room temperature uniformity improved by 90%

• Server failure rate reduced by 60%, ensuring stable financial business operation

• Zero business interruption during renovation, highly recognized by the client

• Cooling efficiency improved by 30%, saving approximately 1.2 million RMB in annual electricity costs

11.3 Case 3: AI Computing Power Center Project

Project Background

An artificial intelligence technology company built an AI training computer room with 200 GPU servers deployed and single cabinet power density of 15kW. Traditional air conditioners failed to meet high heat dissipation demands.

Adopted Solution

Adopted KITOZER 65kW dual-side air supply row-based air conditioning system with 20 units (16 working + 4 standby), equipped with high-temperature cooling modules and cabinet-level micro-environment monitoring system.

Implementation Effects

• Successfully solved GPU high heat generation problems, computer room temperature stabilized at 26℃ with stable server operation

• Supports full-load operation of GPU clusters with 20% improved computing efficiency

• System redundant design ensures uninterrupted AI training tasks

• Intelligent monitoring system tracks real-time temperature of each cabinet for precise cooling capacity adjustment

11.4 Case 4: Modular Data Center Project

Project Background

A telecommunications operator built 5G edge computing nodes with containerized modular data centers, requiring rapid deployment, outdoor environment adaptability and remote management support.

Adopted Solution

Adopted KITOZER integrated row-based air conditioning modules (integrated refrigeration, control and monitoring functions), configuring 10 micro-modules with 4 server cabinets and 2 row-based air conditioners per module.

Implementation Effects

• Container data center completed production and deployment within 30 days and put into operation rapidly

• Row-based air conditioning system with IP54 protection grade adapts to outdoor environments and operates stably

• Intelligent management platform supports remote monitoring and O&M without on-site duty

• System PUE <1.35, meeting green data center standards

12. Search Keywords, SEO & Tags

12.1 Search Keywords

• Computer Room Row-Based Air Conditioning Solution

• KITOZER Row-Based Air Conditioner

• Data Center Row-Level Cooling System

• High-Density Computer Room Air Conditioning Solution

• Low-PUE Row-Based Air Conditioner

• Air-Cooled Direct Expansion Row-Based Air Conditioner

• Chilled Water Row-Based Air Conditioner

• Pump-Assisted Free Cooling Row-Based Air Conditioner

• Intelligent Row-Based Air Conditioning System

• Modular Data Center Air Conditioner

12.2 SEO Optimization Content

1. Title Optimization: KITOZER Row-Based Air Conditioning Solution for Computer Rooms | Data Center Cooling System | PUE Reduction Solution

2. Meta Description: KITOZER row-based air conditioning solution is tailor-made for data centers, adopting row-level cooling technology to reduce PUE, deliver precise temperature control and intelligent management, suitable for various high-density computer room scenarios.

3. Keyword Layout: Reasonably distribute keywords in titles, abstracts, subheadings and body content with a density of 2%-3%.

4. Content Optimization: Provide detailed technical parameters, application cases and customized solutions to enhance content value and readability.

5. Link Optimization: Internal links point to relevant product and solution pages; external links link to authoritative industry websites and standard specifications.

12.3 Tags

#RowBasedAirConditioner #DataCenterCooling #KITOZER #PUEReduction #IntelligentAirConditioner #HighDensityComputerRoom #AirCooledDirectExpansion #ChilledWaterAirConditioner #PumpFreeCooling #ModularDataCenter

Shopping Cart