Table of Contents
Toggle1. System Introduction
1.1 Product Definition
PDU (Power Distribution Unit) is a high-performance power distribution device specially designed for server cabinet environments. As the core hub for terminal power supply in data centers, it connects UPS and mains power to IT equipment to realize safe power distribution, intelligent management and real-time monitoring. Tailored for high-density, high-reliability and intelligent management demands of modern data centers, the KITOZER PDU product line delivers a full set of solutions ranging from basic power distribution to intelligent control, ensuring 7×24-hour stable operation of IT equipment.
1.2 Core Values
- Power Safety Guarantee: Multiple protection mechanisms prevent electrical risks such as overload and short circuit, and eliminate potential fire hazards in computer rooms.
- Resource Optimization & Management: Accurately measure power consumption of each circuit and visualize energy usage to reduce operating costs.
- Upgraded Intelligent O&M: Support remote monitoring and control to cut manual inspection workload and improve management efficiency.
- Enhanced System Reliability: Adopt redundant design and support hot swapping to guarantee continuity of mission-critical services.
- Maximized Space Utilization: 1U standard rack-mounted structure with high-density ports, compatible with all types of server cabinets.

2. System Composition
The KITOZER PDU power distribution system consists of the following core components, forming a complete power supply, distribution and management chain:
| Component | Core Function | Technical Features |
|---|---|---|
| Input Module | Connect UPS or mains power and carry total current | Industrial connectors, 32A/63A high current capacity, anti-misinsertion design |
| Main Control Unit | Core management component for data processing and command execution | Industrial MCU, compatible with multiple communication protocols, fast processing speed |
| Power Distribution Protection Module | Overload, short circuit and surge protection | Magnetic hydraulic circuit breaker with fast response; Lightning protection level ≥20kA, compliant with IEC standards |
| Output Socket Array | Supply stable power to IT equipment | Standard C13/C19 sockets with anti-drop design and hot-swap support |
| Monitoring & Sensing Unit | Real-time collection of electrical parameters | High-precision current transformer, error ≤±0.5%; support voltage, current, power and energy as well as temperature monitoring |
| Display & Interaction Module | Local status display and operation | LCD/LED screen for real-time parameter display and key-based setting |
| Communication Expansion Module | Remote management interface | Support RJ45, WiFi, RS485; compatible with SNMP and Modbus protocols |
| Management Software Platform | Centralized monitoring and data analysis | Visual interface for unified management of multiple devices; historical data storage for more than 1 year |

3. System Classification
KITOZER PDU products are classified by function level, installation method and power phase to meet diverse application requirements.
3.1 Classification by Function Level
| Category | Model Prefix | Core Functions | Applicable Scenarios |
| —- | —- | —- |
| Basic PDU | KT-B | Basic power distribution + LED indicator, no monitoring function | Small computer rooms, non-critical services, budget-limited projects |
| Metering PDU | KT-M | Total current and voltage & power metering, local display | Small and medium-sized computer rooms requiring energy statistics without remote management |
| Switched PDU | KT-S | Independent circuit switch control, remote & local operation | Medium computer rooms needing remote device restart and branch management |
| Intelligent PDU | KT-I | Full parameter monitoring, remote control, alarm and energy analysis | Large data centers, cloud computing centers, core business systems |
| Modular PDU | KT-X | Expandable functional modules for on-demand configuration | Customized demands, high-density computer rooms, flexible expansion scenarios |
3.2 Classification by Installation Method
- 1U Horizontal Type: Standard 19-inch rack mount with 1U height, installed at the top or middle of cabinets.
- 0U Vertical Type: Mounted on cabinet uprights without occupying rack units, ideal for high-density equipment cabinets.
- Wall-mounted Type: Suitable for non-standard cabinets and special installation environments.
3.3 Classification by Power Phase
- Single-phase PDU: 220V input, applicable to ordinary servers and network devices.
- Three-phase PDU: 380V input, applicable to large servers, blade servers and high-density computing equipment.

4. System Configuration List (Brand: KITOZER)
4.1 Basic PDU Configuration List
| No. | Product Name | Model | Specification | Quantity |
| —- | —- | —- | —- |
| 1 | Basic PDU | KT-B16-8C13 | 1U, 16A, 8 × C13 sockets, LED indicator, 1.8m power cord | 1 |
| 2 | Input Power Cord | KT-CORD-16A | 16A industrial plug, 3×2.5mm², length: 1.8m | 1 |
| 3 | Installation Accessories | KT-MOUNT-KIT | 19-inch standard mounting rails and screw kit | 1 |
| 4 | User Manual | KT-MANUAL-B | Operation guide for basic PDU | 1 |
4.2 Intelligent PDU Configuration List
| No. | Product Name | Model | Specification | Quantity |
| —- | —- | —- | —- |
| 1 | Intelligent PDU Main Unit | KT-I32-16C13-4C19 | 1U, 32A, 16 × C13 + 4 × C19 sockets, LCD display, SNMP supported | 1 |
| 2 | Input Power Cord | KT-CORD-32A | 32A industrial plug, 5×4mm², length: 2.0m | 1 |
| 3 | Communication Module | KT-COM-RJ45 | RJ45 Ethernet port, support SNMP v3 & Modbus TCP | 1 |
| 4 | Environment Sensor | KT-SENSOR-TH | Temperature & humidity sensor; Range: -10℃ ~ 60℃, 0% ~ 95%RH | 1 |
| 5 | Installation Accessories | KT-MOUNT-KIT-PRO | 19-inch rails, cable manager and fixing screws | 1 |
| 6 | Management Software | KT-MANAGER-SE | Standalone intelligent PDU management software, compatible with Windows & Linux | 1 |
| 7 | User Manual | KT-MANUAL-I | Operation & maintenance guide for intelligent PDU | 1 |
4.3 Three-phase Intelligent PDU Configuration List
| No. | Product Name | Model | Specification | Quantity |
| —- | —- | —- | —- |
| 1 | Three-phase Intelligent PDU Main Unit | KT-I3P63-42 | 3-phase 380V, 63A, 42 outputs (30 × C13 + 12 × C19), 6 magnetic hydraulic circuit breakers | 1 |
| 2 | Input Power Cord | KT-CORD-3P63A | 3-phase 63A industrial plug, 5×10mm², length: 2.5m | 1 |
| 3 | Communication Expansion Module | KT-COM-WIFI | WiFi + RJ45 dual ports, cloud platform access supported | 1 |
| 4 | Environment Monitoring Kit | KT-SENSOR-KIT | Temperature, humidity, smoke and water leakage sensors for all-round monitoring | 1 |
| 5 | Installation Kit | KT-MOUNT-3P | Special bracket for three-phase PDU, load capacity ≥50kg | 1 |
| 6 | Management Platform | KT-MANAGER-ENTERPRISE | Enterprise-level multi-device management platform, manage over 1000 PDUs | 1 |
| 7 | Technical Documents | KT-DOC-3P | Complete documents for installation, configuration and maintenance of three-phase PDU | 1 |

5. System Schematic Diagram
5.1 Block Diagram of Basic PDU
Mains / UPS Input → Industrial Connector → Main Circuit Breaker → Busbar → Branch Protection → Output Socket Array → LED Indicator
5.2 Block Diagram of Intelligent PDU
Mains / UPS Input → Industrial Connector → Main Circuit Breaker → Busbar → Branch Protection → Output Socket Array → Monitoring & Sensing Unit → Main Control Unit → Display & Interaction Module
↓
Communication Expansion Module → Remote Management Platform / Mobile Terminal
↓
Alarm Output → Audible & Visual Alarm / SMS / Email Notification
5.3 Wiring Diagram of Three-phase PDU
380V Three-phase Input → Three-phase Industrial Plug → Three-phase Main Circuit Breaker → Phase A/B/C Busbar → 6 Branch Magnetic Hydraulic Circuit Breakers (2 per phase) → Each Circuit: 5 × C13 + 2 × C19 Sockets → Load Devices

6. Product Technical Parameters
6.1 General Technical Parameters
| Parameter Category | Technical Index | Remarks |
|---|---|---|
| Input Voltage | Single-phase: 220V AC ±10%; Three-phase: 380V AC ±10% | Wide voltage tolerance for various power supply environments |
| Rated Current | Single-phase: 16A / 32A; Three-phase: 32A / 63A | Meet power demands of different loads |
| Output Sockets | Standard C13/C19, 8~42 sockets optional | Compatible with servers, switches and other IT devices |
| Protection Functions | Overload, short circuit and surge protection (≥20kA) | Magnetic hydraulic circuit breaker, response time ≤5ms |
| Insulation Resistance | ≥100MΩ (500V DC) | Ensure electrical safety |
| Dielectric Strength | 2500V AC, no breakdown within 1 minute | Compliant with IEC 60950 |
| Operating Temperature | -10℃ ~ +40℃ | Adapt to computer room environment |
| Storage Temperature | -20℃ ~ +60℃ | Suitable for transportation and storage |
| Relative Humidity | 10% ~ 90% (Non-condensing) | Adapt to climates of different regions |
| Protection Class | IP20 | Prevent fingers from touching live parts |
| Installation Method | 1U Horizontal / 0U Vertical / Wall-mounted | Flexible for various cabinets |
6.2 Special Parameters for Intelligent PDU
| Parameter Category | Technical Index | Remarks |
|---|---|---|
| Monitoring Accuracy | Voltage: ±0.5%; Current: ±0.5%; Power: ±1.0% | High precision for energy audit |
| Communication Interface | RJ45 / WiFi / RS485 | Adapt to multiple network environments |
| Communication Protocol | SNMP v3, Modbus TCP/RTU, HTTP/HTTPS | Compatible with mainstream management platforms |
| Data Storage | Local storage for over 10,000 records; Data retention for over 10 years after power failure | Prevent data loss |
| Remote Control | Single / multi-circuit switch, sequential power on & off | Avoid inrush current caused by simultaneous startup |
| Alarm Mode | Audible & visual alarm, SMS, Email, SNMP Trap | Multi-channel timely fault notification |
| User Management | Multi-level authority & operation log recording | Meet network security assessment and audit requirements |

7. Product Application Scope
KITOZER PDU power distribution units are widely applied in the following scenarios:
7.1 Data Center Scenarios
- Large IDC computer rooms with high-density server clusters requiring intelligent monitoring and remote management
- Cloud computing centers needing accurate energy metering and dynamic load management for virtualized environments
- Edge computing nodes with distributed deployment requiring remote operation and maintenance as well as fault early warning
7.2 Enterprise IT Scenarios
- Enterprise core computer rooms with critical services requiring high reliability and redundant design
- R&D and test centers with frequently replaced devices requiring flexible power distribution and safety protection
- Disaster recovery centers with active-active & multi-active architectures requiring remote switching and status synchronization
7.3 Special Industry Scenarios
- Financial institutions: Data centers of banks and securities companies requiring compliance audit and high security
- Government agencies: Government cloud platforms requiring hierarchical control and data encryption
- Healthcare industry: Medical equipment rooms requiring stable power supply and electromagnetic compatibility
- Military industry: Command and control systems requiring anti-interference and military-grade protection
- Education & research: University data centers requiring cost control and energy analysis

8. Product Advantages
8.1 Full Product Line for Diversified Demands
KITOZER delivers a complete range of PDUs including basic, intelligent, single-phase and three-phase models, covering demands from small computer rooms to large data centers, and supporting customized configuration.
8.2 Multiple Safeguards for Power Security
- Magnetic Hydraulic Circuit Breaker: 5 times faster response than traditional air switches for more accurate overload protection.
- Three-level Lightning Protection: Differential mode + common mode protection, surge suppression capacity ≥20kA, compliant with IEC 61000-4-5.
- Flame-retardant Housing: V0 grade flame-retardant material to stop fire spread.
- Anti-misinsertion Design: Industrial connectors to avoid electrical faults caused by wrong connection.
8.3 Intelligent Management to Improve O&M Efficiency
- Remote Monitoring: Check load status of each circuit via Web or APP without on-site inspection.
- Remote Control: Switch or restart devices remotely to quickly troubleshoot and reduce downtime.
- Energy Analysis: Accurately measure power consumption of each device and generate reports for energy optimization.
- Alarm Mechanism: Multi-channel alarms (audible & visual, SMS, Email, SNMP Trap) for timely response to abnormalities.
8.4 Industrial-grade Quality for Long-term Stable Operation
- Integrated Copper Busbar: Contact resistance ≤5mΩ to reduce heat generation and improve conductivity.
- Industrial Components: MTBF ≥100,000 hours, supporting 7×24-hour continuous operation.
- Strict Testing: 100% factory inspection including aging test, voltage withstand test and EMC test.
- IP20 Protection: Prevent dust and foreign matter from entering and protect internal circuits.
8.5 Flexible Installation to Optimize Space Utilization
- 1U / 0U Installation: Adapt to various cabinets and maximize rack space utilization.
- Modular Design: Configurable functional modules for post-expansion.
- Cable Management Optimization: Built-in cable grooves to tidy wiring and beautify computer rooms.

9. Bidding Parameters
9.1 Bidding Parameters for Basic PDU
- Brand: KITOZER, Model: KT-B Series
- Installation: 1U horizontal mounting, compatible with 19-inch standard cabinets
- Input: 220V AC, 16A / 32A optional, industrial anti-misinsertion connector
- Output: Standard C13 sockets, 8/10/12 sockets optional with anti-drop design
- Protection: Overload & short circuit protection, magnetic hydraulic circuit breaker, response time ≤5ms
- Indicator: LED lamp for power status display
- Housing: V0 grade flame-retardant aluminum alloy with good heat dissipation and light weight
- Certification: CE, FCC, RoHS, compliant with IEC 60950-1
9.2 Bidding Parameters for Intelligent PDU
- Brand: KITOZER, Model: KT-I Series
- Installation: 1U horizontal mounting, 0U vertical mounting optional
- Input: 220V AC / 380V AC, 16A / 32A / 63A optional, industrial connector
- Output: Mixed C13 & C19 sockets (16~42 optional), independent switch for each circuit
- Monitoring: Support voltage, current, power, energy, temperature and humidity monitoring; accuracy ≥±0.5%
- Control: Remote single/multi-circuit switch and sequential power on/off, task scheduling supported
- Interface: RJ45 + WiFi dual ports, support SNMP v3, Modbus TCP/RTU
- Display: LCD screen for real-time parameter display and key operation
- Alarm: Audible & visual alarm, SMS, Email and SNMP Trap multi-channel alarm
- Certification: CE, FCC, RoHS, ISO9001, compliant with Class A data center standards
9.3 Bidding Parameters for Three-phase PDU
- Brand: KITOZER, Model: KT-I3P Series
- Input: 380V AC three-phase five-wire system, 32A / 63A optional, industrial connector
- Output: 6 independent protection circuits, 5×C13 + 2×C19 per circuit, total 42 sockets
- Protection: 6 magnetic hydraulic circuit breakers with independent protection for each circuit, response time ≤5ms
- Monitoring: Three-phase voltage, current, power and energy monitoring, accuracy ≥±0.5%; three-phase balance analysis supported
- Communication: Cloud platform access, unified management for over 1000 PDUs
- Redundancy: Dual power input and automatic switching to ensure power continuity
- EMC: Compliant with EN 55022 Class A, strong anti-interference capability
10. Product Solutions
10.1 Solution for Small Enterprise Computer Rooms
Applicable Scenarios: 20~50 servers, non-critical services, limited budget
Solution Configuration: Combine KT-B basic PDU and KT-M metering PDU
- Deploy KT-M metering PDU for core switches and database servers to realize energy monitoring
- Adopt KT-B basic PDU for ordinary devices to provide basic power distribution and protection Advantages: Cost-effective, meet basic safety requirements and support future upgrade to intelligent PDU
10.2 Solution for Medium Enterprise Core Computer Rooms
Applicable Scenarios: 50~200 servers, 7×24-hour core business systems
Solution Configuration: Deploy KT-I intelligent PDU, 2 units per cabinet for A+B redundant power supply
- Equip with KT-MANAGER-SE local management software for centralized monitoring
- Connect key devices to separate PDUs with dual power supplies for power continuity Advantages: Remote management, rapid fault location, visualized energy consumption and improved O&M efficiency
10.3 Solution for Large Data Centers & Cloud Computing Centers
Applicable Scenarios: More than 200 servers, high-density computing power
Solution Configuration: Deploy KT-I3P three-phase intelligent PDU for 380V high-voltage high-density load; adopt KT-MANAGER-ENTERPRISE enterprise management platform
- Equip with environment monitoring kits for full monitoring of cabinet micro-environment
- Adopt dual power input + STS static transfer switch for zero power interruption Advantages: Support high-density computing, intelligent load balancing, refined energy management and compliance with green data center standards
10.4 Customized Solution
For special industries (finance, medical treatment, military) and personalized demands:
- Custom special interfaces (e.g. IEC 60309 industrial connectors)
- Custom functions such as sequential power on/off and remote firmware upgrade
- Adapt to high temperature, high humidity and strong electromagnetic interference environments
- Develop exclusive management platforms to meet industry compliance requirements
11. Application Cases
11.1 Case 1: Cloud Computing Data Center of an Internet Company
Project Profile: New cloud computing data center with over 1000 cabinets, high-density computing power, requiring 7×24-hour operation and energy control
Solution:
- Deploy KT-I3P three-phase intelligent PDUs for all cabinets (380V/63A input, 42 outputs)
- Adopt KT-MANAGER-ENTERPRISE platform to manage more than 1000 PDUs uniformly
- Configure 2 PDUs per cabinet for A+B redundant power supply
- Equip with environment monitoring kits for real-time monitoring of temperature, humidity, smoke and water leakage
Implementation Effect:
- Power availability increased to 99.999%, annual downtime ≤5.25 minutes
- Energy consumption reduced by 12% via refined management
- O&M efficiency improved by 60%; 80% of faults solved remotely
- Visualized energy data supports green data center certification
11.2 Case 2: Disaster Recovery Center of a Bank
Project Profile: Bank disaster recovery center requiring zero data loss, zero power interruption and full compliance with financial regulations
Solution:
- Deploy KT-I intelligent PDUs with dual power input and STS static transfer switch
- Configure independent communication modules for each PDU to realize dual link redundancy
- Adopt hierarchical authority management; operation logs stored permanently to meet audit requirements
- Equip surge protection module with lightning protection level ≥20kA
Implementation Effect:
- Pass the financial technology safety assessment of the central bank
- Achieve zero power interruption and ensure the disaster recovery system is always available
- Comply with Class 3 Cybersecurity Protection Level; all operations traceable
- On-site inspection workload reduced by 90% via remote O&M
11.3 Case 3: University Data Center
Project Profile: University data center with limited budget, requiring high cost performance and expandability
Solution: Mixed deployment of KT-B basic PDUs and KT-M metering PDUs
- Use KT-M metering PDUs for database servers and core switches to monitor energy consumption
- Use KT-B basic PDUs for common devices to control costs
- Reserve upgrade interfaces for smooth migration to intelligent PDUs in the future
Implementation Effect:
- Overall cost cut by 30% while meeting basic safety standards
- Energy statistics data supports energy-saving renovation
- Good expandability to protect early investment
- Simple operation, suitable for university IT teams
12. Search Keywords, SEO & Tags
12.1 Search Keywords
- KITOZER PDU Power Distribution Unit
- Server Cabinet PDU Solution
- Intelligent PDU Remote Management System
- Three-phase High-density PDU Power Supply
- Data Center Power Distribution Solution
- Cabinet PDU Redundant Design
- PDU Energy Monitoring System
- Computer Room Power Safety Solution
12.2 SEO Optimization
- Title: KITOZER Cabinet PDU Power Distribution Unit Solution – Intelligent Management | Safe Power Distribution | Energy Optimization
- Meta Description: KITOZER PDU provides a full range of solutions from basic power distribution to intelligent control. It supports remote monitoring, energy analysis and multiple safety protections, and is applicable to data centers and enterprise computer rooms to ensure 7×24-hour stable operation of IT equipment.
- Core Keywords: KITOZER PDU, Cabinet PDU, Intelligent PDU, Power Distribution Unit, Data Center Power Management
12.3 Tags
#KITOZER #PDU #Computer Room Power #Intelligent Power Distribution #Data Center #Power Management #Energy Monitoring #Safety Protection #Redundant Design #Remote O&M #Green Data Center