1. System Introduction

The KITOZER intelligent liquid cooling cabinet is a high-efficiency heat dissipation infrastructure tailored for new-generation data centers, AI computing clusters and edge computing nodes. Adopting a modular design concept, it integrates advanced liquid cooling technology, intelligent monitoring system and redundant guarantee mechanism. It supports ultra-high power density heat dissipation of 10kW~100kW per cabinet with a PUE as low as below 1.10, delivering a green, efficient and stable cooling solution for high-density computing scenarios.

Guided by four core design principles of precision heat dissipation, intelligent control, high efficiency & energy saving, safety & reliability, the system applies multiple liquid cooling technologies including cold plate, immersion and spray cooling to directly act on heat sources. It greatly improves heat dissipation efficiency and reduces overall energy consumption of data centers. Meanwhile, it supports rapid deployment and flexible expansion, fully adapting to full-scenario application requirements from micro edge computer rooms to large-scale intelligent computing centers.

2. System Composition

The KITOZER intelligent liquid cooling cabinet system adopts a three-layer architecture, forming a complete heat dissipation link from heat source to cold source. All components work collaboratively to ensure stable and efficient system operation.

LevelCore ComponentsFunction Description
Cabinet LevelIntelligent liquid cooling cabinet main bodyLiquid cooling manifold distribution unitQuick connectors & flexible pipelinesLiquid leakage detection systemIntelligent PDUCabinet monitoring moduleCarry server equipment, realize coolant distribution and recovery inside the cabinet, real-time monitor cabinet temperature, pressure, leakage and other parameters, and provide safe power supply and remote management capabilities.
Computer Room LevelCoolant Distribution Unit (CDU)Plate heat exchangerCirculating pump setFiltration systemLiquid replenishment deviceComputer room monitoring platformSupply stable coolant circulation for multiple cabinets, realize heat transfer through secondary side heat exchange, and achieve precise flow & temperature control and automatic fault switching.
Cold Source LevelDry cooler / Cooling towerChiller (optional)Backup cold source systemProvide primary cold source to dissipate heat to the environment, support automatic switching between natural cooling and mechanical refrigeration to maximize energy-saving benefits.
intelligent liquid cooled cabinet solution (8)

2.1 Cabinet Main Structure

  • Standard 19-inch rack, supporting 42U/48U installation space and compatible with mainstream server equipment
  • High-strength steel structure with load capacity ≥1500kg and IP54 protection level
  • Modular design supporting rapid switching of cold plate, immersion and spray liquid cooling solutions
  • Integrated cable management system, supporting multiple wiring methods including top-in top-out and bottom-in bottom-out

2.2 Liquid Cooling Distribution System

  • 304 stainless steel manifold with design pressure of 1.0MPa, corrosion resistance and long service life
  • Custom self-sealing quick connectors with zero leakage during plugging and unplugging, supporting online server replacement
  • Food-grade flexible pipelines with low flow resistance, adapting to complex wiring environments inside cabinets
  • Flow regulating valves support independent flow control for single server to meet differentiated heat dissipation requirements

2.3 Intelligent Monitoring System

  • Distributed sensor network, real-time collection of temperature (accuracy ±0.5℃), pressure (accuracy ±0.01MPa), flow and other parameters
  • Edge computing gateway supports local data processing and edge decision-making with response time ≤1 second
  • Compatible with multiple communication protocols such as SNMP, Modbus and TCP/IP for seamless access to third-party management platforms
  • Intelligent alarm mechanism with multi-level alarm and automatic fault isolation to ensure system operation safety
intelligent liquid cooled cabinet solution (7)

3. System Classification

KITOZER intelligent liquid cooling cabinets are classified by heat dissipation technology, deployment scale and application scenarios to meet diversified user requirements.

3.1 Classification by Heat Dissipation Technology

Technology TypeCore FeaturesApplication ScenariosHeat Dissipation CapacityPUE Range
Cold Plate Liquid Cooling CabinetIndirect contact heat dissipation. Cold plates are attached to high-heat devices such as CPU/GPU without changing the original server structure, featuring strong compatibilityExisting computer room renovation, general computing scenarios, edge computing nodes10kW~40kW per cabinet1.15~1.25
Immersion Liquid Cooling CabinetDirect contact heat dissipation. Servers are fully immersed in insulating coolant with extremely high heat dissipation efficiency and low noiseAI training clusters, supercomputing centers, high-density computing scenarios40kW~100kW per cabinet1.05~1.10
Spray Liquid Cooling CabinetDirectional coolant spraying on chip surfaces, balancing heat dissipation efficiency and maintenance convenienceHigh-performance computing, database clusters, mixed load scenarios30kW~80kW per cabinet1.10~1.20
intelligent liquid cooled cabinet solution (6)

3.2 Classification by Deployment Scale

  1. Single Cabinet Independent System: Integrated CDU functions without external cooling equipment, featuring flexible deployment and plug-and-play, suitable for micro data centers and edge computing nodes.
  2. Multi-cabinet Cluster System: Adopts distributed CDU design to provide centralized cooling for multiple cabinets, with redundant design and high reliability for small and medium-sized data centers.
  3. Large Modular System: Compliant with OCP open standards, supporting rapid cabinet-level expansion and adapting to large-scale intelligent computing centers with single cabinet power density over 100kW.

3.3 Classification by Application Scenario

  • Edge Liquid Cooling Cabinet: Compact design, supporting wide-temperature operation (-40℃~55℃), applicable to 5G base stations, industrial edge computing and outdoor computer rooms.
  • AI Training Dedicated Cabinet: Optimized for GPU clusters, supporting multi-card parallel heat dissipation, compatible with high-performance computing cards such as NVIDIA H100/A100 and AMD MI250.
  • High-density Storage Cabinet: Optimized airflow and liquid flow design, adapting to high-density storage servers, reducing vibration impact and extending hard disk service life.
  • Liquid Cooling Container: Integrated prefabricated design with on-site rapid deployment within 7 days, suitable for emergency computer rooms, temporary computing capacity expansion and remote area data centers.
intelligent liquid cooled cabinet solution (5)

4. System Configuration List (Brand: KITOZER)

4.1 Standard Configuration List of Cold Plate Liquid Cooling Cabinet

No.Equipment NameModelSpecification ParametersQuantityRemarks
1Intelligent Liquid Cooling CabinetKITOZER-LC-CP42U42U, 600W×1200D×2200Hmm, load capacity 1500kg1 SetIncluding front/rear doors, side panels, top & bottom panels
2Cabinet Liquid Cooling ManifoldKITOZER-MF-300304 stainless steel, 1-in 12-out, flow rate 300L/min, working pressure 1.0MPa1 SetIncluding liquid inlet/return main pipelines
3Cold Plate AssemblyKITOZER-CP-200Copper-aluminum composite material, compatible with 2U/4U servers, heat exchange area ≥0.8m²On-demandIncluding mounting bracket and thermal conductive medium
4Quick ConnectorKITOZER-QD-10Self-sealing, bore diameter 10mm, plugging life ≥5000 timesOn-demand2 pcs per server (inlet & return)
5Flexible PipelineKITOZER-HOSE-10Food-grade PE material, inner diameter 10mm, pressure resistance 1.6MPaOn-demandCustomizable length
6Liquid Leakage Detection SystemKITOZER-LD-88-channel, detection accuracy 0.1ml, response time ≤2s1 SetIncluding sensors and alarm module
7Intelligent PDUKITOZER-PDU-32A32A input, 16-channel output, supporting remote monitoring and switch control2 SetsRedundant configuration
8Cabinet Monitoring ModuleKITOZER-IM-200Supports temperature/humidity/pressure/flow/access control/video monitoring1 SetEquipped with 7-inch touch screen
9Cable Management SystemKITOZER-CM-42UAdapted to 42U cabinets, supporting separate management of power and signal cables1 SetIncluding cable organizers and trunking
10Safety Protection KitKITOZER-SP-01Including fire extinguisher, emergency lighting, protective gloves1 SetStandard safety configuration

4.2 CDU Centralized Cooling Unit Configuration List

No.Equipment NameModelSpecification ParametersQuantityRemarks
1Coolant Distribution Unit (CDU)KITOZER-CDU-120Dual-pump redundancy, maximum flow 120m³/h, temperature control accuracy ±1℃1 SetIncluding control system and touch screen
2Plate Heat ExchangerKITOZER-HE-100Heat exchange area 100m², heat exchange efficiency ≥95%1 Set316L stainless steel material
3Circulating Pump SetKITOZER-PUMP-50Flow 50m³/h, head 30m, variable frequency control2 SetsMaster-standby automatic switching, fault self-switching supported
4Precision Filtration SystemKITOZER-FILTER-200Filtration accuracy 10μm, automatic backwashing, differential pressure alarm1 SetIncluding front and rear pressure gauges
5Liquid Replenishment DeviceKITOZER-FILL-5050L capacity, automatic liquid replenishment, low liquid level alarm1 SetIncluding liquid level sensor
6Electrical Control CabinetKITOZER-EC-60Equipped with PLC, frequency converter, relay and other control components1 SetSupports remote communication
7Monitoring SoftwareKITOZER-MON-3.0Supports Web/mobile terminal access, real-time monitoring and data analysis1 SetFree lifelong software upgrade service

4.3 Cold Source System Configuration List

No.Equipment NameModelSpecification ParametersQuantityRemarks
1Dry CoolerKITOZER-DC-200Heat exchange capacity 200kW, supporting natural cooling1 SetIncluding fan and spray system
2Backup ChillerKITOZER-CH-150Cooling capacity 150kW, energy efficiency ratio ≥4.21 SetOptional configuration for extreme working condition guarantee
3Pipeline SystemKITOZER-PIP-01Seamless steel pipe, pressure resistance 1.6MPa, thermal insulation treatment1 SetIncluding valves, flanges and brackets
4Automatic Control SystemKITOZER-ACS-01Supports intelligent switching between natural cooling and mechanical refrigeration1 SetIncluding temperature and pressure sensors
intelligent liquid cooled cabinet solution (4)

5. System Schematic Diagram

5.1 Working Principle of Cold Plate Liquid Cooling System

Plain Text
Server Heat Source (CPU/GPU) → Cold Plate (Copper-aluminum Composite) → Flexible Pipeline → Cabinet Manifold →
CDU (Circulating Pump → Plate Heat Exchanger → Filtration System) → Dry Cooler/Cooling Tower → Environment
  â†‘                                 |
  |                                 â†“
  â””─────────────────────────────────┘
        (Secondary Coolant Circulation Path)

System Working Process:

  1. The cold plate is closely attached to high-heat components such as server CPU/GPU through thermal conductive medium to absorb heat.
  2. The heated coolant flows into the cabinet manifold through flexible pipelines, converges and is transported to the CDU.
  3. The CDU delivers the coolant to the plate heat exchanger via circulating pumps for heat exchange with the primary cold source.
  4. The cooled coolant returns to the cabinet manifold and is redistributed to each cold plate to form a closed-loop circulation.
  5. The primary cold source dissipates heat to the environment through dry coolers or cooling towers to complete the heat dissipation process.
  6. The whole link realizes real-time monitoring of temperature, pressure, flow and other parameters to ensure stable system operation.

5.2 Working Principle of Immersion Liquid Cooling System

Plain Text
Server (Fully Immersed in Insulating Coolant) → Coolant (Heat Absorption) → Cabinet Internal Circulating Pump →
External Heat Exchanger → Dry Cooler/Cooling Tower → Environment
  â†‘                              |
  |                              â†“
  â””──────────────────────────────┘
        (Coolant Circulation Path)

System Features:

  • Servers are fully immersed in 3M Novec or customized insulating coolant, with heat dissipation efficiency over 30% higher than cold plate cooling.
  • Adopts single-phase/two-phase immersion technology; the two-phase system achieves a PUE as low as 1.05 with remarkable energy-saving effect.
  • Integrated circulating pump and heat exchanger inside the cabinet support independent single-cabinet operation or connection to centralized CDU systems.
intelligent liquid cooled cabinet solution (3)

6. Product Technical Parameters

6.1 Technical Parameters of Cold Plate Liquid Cooling Cabinet

Parameter CategoryDetailed Specifications
Physical ParametersDimension: 600W×1200D×2200Hmm (42U)Weight: 200kg (excluding equipment)Material: High-quality SPCC steel with electrostatic spray surface treatmentProtection Level: IP54
Heat Dissipation PerformanceSingle cabinet heat dissipation capacity: 10kW~40kWCoolant inlet temperature: 20℃~35℃Coolant outlet temperature: ≤45℃Temperature control accuracy: ±1℃
Liquid Circuit SystemWorking pressure: 0.3~0.8MPaMaximum flow rate: 300L/minManifold interface: 12~24 channels (optional)Quick connector: bore diameter 10mm, plugging force <50N
Electrical ParametersInput voltage: 380V/220V AC, 50HzPDU output: 16-channel C13/C19 interfacesMonitoring module power consumption: ≤50WLiquid leakage detection sensitivity: 0.1ml
Environmental ParametersOperating temperature: -10℃~40℃Relative humidity: 10%~90% (non-condensing)Altitude: ≤2000mSeismic grade: Earthquake resistance intensity of grade 8
Intelligent FeaturesSupport remote monitoring and managementAutomatic fault alarm and positioningMulti-protocol access (Modbus/TCP/IP, SNMP)Mobile APP real-time monitoring supported

6.2 Technical Parameters of CDU Centralized Cooling Unit

Parameter CategoryDetailed Specifications
Physical ParametersDimension: 800W×1200D×2000HmmWeight: 500kg (with liquid)Installation method: Floor-standing / cabinet type
Performance ParametersMaximum liquid supply capacity: 120m³/hTemperature control range: 15℃~35℃Temperature control accuracy: ±0.5℃Pressure control accuracy: ±0.02MPa
Pump Set ConfigurationDual-pump redundant design with automatic master-standby switchingVariable frequency control, flow adjustment range: 30%~100%Pump efficiency: ≥80%
Heat Exchange SystemPlate heat exchanger, heat exchange area: 100m²Heat exchange efficiency: ≥95%Material: 316L stainless steel
Monitoring System7-inch color touch screen, local/remote control supportedReal-time monitoring parameters: inlet/outlet temperature & pressure, flow, liquid level, energy consumptionSupport fault diagnosis and automatic protection functions
intelligent liquid cooled cabinet solution (2)

7. Product Application Scope

With the advantages of high heat dissipation efficiency, low energy consumption and flexible deployment, KITOZER intelligent liquid cooling cabinets are widely applied in the following scenarios:

7.1 Data Center Field

  • Large-scale Intelligent Computing Centers: Adapt to ultra-high power density AI training clusters of 40kW~100kW per cabinet with PUE as low as 1.05, greatly reducing operating costs.
  • Edge Data Centers: Compact design supports wide-temperature operation, suitable for 5G base stations and industrial internet edge nodes.
  • High-density Computer Room Renovation: No large-scale infrastructure transformation is required. The single cabinet power of traditional computer rooms can be increased from 5kW to over 40kW, extending the service life of computer rooms.

7.2 Industry-specific Scenarios

IndustryTypical ApplicationsCore Values
Financial IndustryHigh-frequency trading systems, core database clustersEnsure stable system operation, reduce computer room energy consumption and meet green financial requirements
Internet IndustryShort video AI processing, cloud computing data centersSupport rapid capacity expansion, adapt to sudden traffic, reduce PUE and enhance market competitiveness
Scientific Research FieldSupercomputers, meteorological & ocean simulation platformsMeet ultra-high power density heat dissipation requirements and support long-term stable operation
Manufacturing IndustryIndustrial internet platforms, intelligent manufacturing data centersAdapt to complex factory environments and support integrated edge computing and centralized management
Medical IndustryMedical image processing, gene sequencing platformsGuarantee high-precision computing, reduce equipment noise and improve working environment
Energy IndustrySmart grid dispatching systems, new energy monitoring platformsAdapt to remote deployment, support natural cooling and reduce operation and maintenance costs

7.3 Special Application Scenarios

  • Liquid Cooling Container Data Center: Factory prefabricated with on-site rapid deployment within 7 days, suitable for emergency disaster relief, temporary computing capacity expansion and remote data center construction.
  • Vehicle/ship-mounted Data Center: Anti-vibration design supports wide-temperature operation, adapting to mobile computing scenarios.
  • Military/Aerospace Industry: High-reliability design adapts to extreme environments and meets military computing and data storage requirements.
intelligent liquid cooled cabinet solution (1)

8. Product Advantages

8.1 High-efficiency Heat Dissipation & Extreme Energy Saving

  • 50%+ Higher Heat Dissipation Efficiency: Compared with traditional air cooling, liquid cooling improves heat dissipation efficiency by more than 50%, increasing single cabinet power density from 5kW to over 40kW.
  • Ultra-low PUE: Immersion liquid cooling system PUE reaches 1.05, and cold plate liquid cooling system PUE ranges from 1.15 to 1.25, saving 30%-50% energy compared with traditional air-cooled computer rooms.
  • High Natural Cooling Utilization: Support wide temperature range operation of 15℃~35℃, greatly extending natural cooling time and further reducing energy consumption.

8.2 Intelligent Management & Convenient O&M

  • Full-link Monitoring: Real-time monitoring of more than 20 parameters including temperature, pressure, flow and leakage to pre-warn potential faults.
  • Remote Intelligent Management: Support Web/mobile remote monitoring and control to realize unattended operation and reduce O&M costs.
  • Automatic Fault Processing: Support automatic fault isolation and master-standby switching, achieving system availability of 99.999%.
  • Intelligent Energy Consumption Analysis: Built-in AI algorithm optimizes operating parameters to achieve the best balance between energy consumption and heat dissipation efficiency.

8.3 Safety & Stable Operation

  • Multi-level Safety Protection: Multiple safety mechanisms including liquid leakage detection, overpressure protection, overheating protection and power-off protection ensure equipment and personnel safety.
  • Redundant Design: CDU adopts dual-pump, dual-heat exchanger and dual-power redundant configuration to avoid system shutdown caused by single-point failure.
  • Insulating Coolant: The immersion system adopts 3M Novec and other insulating coolants, which are non-conductive and non-flammable to ensure server safety.
  • Fire & Explosion Proof: The whole system adopts flame-retardant materials, complying with UL94 V-0 fire protection standard.

8.4 Flexible Deployment & Strong Adaptability

  • Modular Design: Support rapid switching of cold plate, immersion and spray liquid cooling solutions to adapt to different application scenarios.
  • Rapid Deployment: Factory prefabrication reduces on-site installation time by 70%, supporting small-scale data center deployment within 7 days.
  • Seamless Expansion: Support cabinet-level expansion, enabling smooth scaling from single cabinet to thousands of cabinets.
  • Standard Equipment Compatibility: Adapt to mainstream servers, switches and other IT equipment without customized modification.

9. Bid-winning Control Parameters

9.1 Core Technical Parameter Requirements

  1. Heat Dissipation Capacity: Single cabinet heat dissipation capacity ≥40kW, maximum single cabinet power density ≥60kW.
  2. PUE Value: Cold plate liquid cooling system PUE ≤1.20, immersion liquid cooling system PUE ≤1.10.
  3. Temperature Control: Coolant outlet temperature control accuracy ≤±1℃, supporting wide range adjustment of 15℃~35℃.
  4. Liquid Leakage Detection: The system is equipped with distributed liquid leakage detection function with detection sensitivity ≤0.1ml and response time ≤2 seconds.
  5. Redundant Design: CDU adopts dual-pump and dual-heat exchanger redundant configuration with automatic fault switching and switching time ≤5 seconds.
  6. Quick Connector: Adopt self-sealing quick connectors with plugging life ≥5000 times and zero liquid leakage during plugging and unplugging.
  7. Material Requirements: Key liquid circuit components (manifold, heat exchanger) adopt 304/316L stainless steel with design pressure ≥1.0MPa.
  8. Monitoring Capability: Support real-time monitoring of more than 20 parameters such as temperature, pressure, flow, liquid level and energy consumption, with remote management function.

9.2 Qualification & Certification Requirements

  1. Possess ISO9001 quality management system certification, ISO14001 environmental management system certification and ISO45001 occupational health and safety management system certification.
  2. The liquid cooling system has international certifications such as CE, UL and ETL, complying with IEC61935 standards.
  3. The liquid leakage detection system is equipped with third-party test reports with detection accuracy meeting industry standards.
  4. The product has passed national data center energy-saving product certification with PUE reaching the national first-class energy efficiency standard.

9.3 Service & Guarantee Requirements

  1. Provide a warranty period of no less than 5 years, and the warranty period for core components (CDU, pump set, heat exchanger) is no less than 3 years.
  2. Provide 7×24-hour technical support with fault response time ≤2 hours and on-site service time ≤24 hours.
  3. Provide one-stop services including system design, installation, commissioning and training.
  4. Provide lifelong free software upgrade services to ensure long-term stable system operation.

10. Product Solution

10.1 Solution Design Process

The KITOZER intelligent liquid cooling cabinet solution follows a five-step process of demand analysis → solution design → product selection → deployment implementation → operation and maintenance service to ensure accurate matching with user requirements.

  1. Demand Analysis: Evaluate core requirements such as user IT equipment power density, deployment scale, computer room conditions and energy-saving goals.
  2. Solution Design: Select cold plate/immersion/spray liquid cooling technical routes according to requirements, and design cabinet layout, pipeline routing and CDU configuration.
  3. Product Selection: Select matching liquid cooling cabinets, CDU, cold sources and other products based on the design scheme to ensure system compatibility and reliability.
  4. Deployment Implementation: Adopt factory prefabrication + on-site rapid installation mode, with professional teams completing system commissioning and acceptance.
  5. Operation & Maintenance Service: Provide remote monitoring platform and regular maintenance services to ensure long-term stable system operation.

10.2 Typical Scenario Solutions

10.2.1 AI Intelligent Computing Center Solution

Solution Overview: Adopt immersion liquid cooling cabinet + distributed CDU + natural cooling system to adapt to 40kW~100kW per cabinet AI training clusters with PUE as low as 1.05.

Core Configuration:

  • KITOZER-LC-IM48U immersion liquid cooling cabinet, supporting 48U installation space and single cabinet heat dissipation capacity of 60kW
  • KITOZER-CDU-200 distributed CDU, providing centralized cooling for 10 cabinets
  • 3M Novec 7300 insulating coolant, non-conductive and non-flammable, adapting to high-density heat dissipation requirements of AI servers
  • Intelligent monitoring platform, optimizing coolant flow and temperature via AI algorithm to maximize energy-saving effect

Implementation Effect:

  • Single cabinet power density increased to 8 times that of traditional air cooling, and computer room space utilization increased by 60%
  • PUE reduced from 1.8 (traditional air cooling) to 1.05, with annual power saving rate over 40%
  • Server failure rate reduced by 50% and service life extended by 3 years
  • Noise reduced below 60dB, improving computer room working environment

10.2.2 Edge Data Center Solution

Solution Overview: Adopt cold plate liquid cooling cabinet + integrated CDU + dry cooler system to adapt to 10kW~20kW per cabinet edge computing nodes and support wide-temperature operation.

Core Configuration:

  • KITOZER-LC-CP42U cold plate liquid cooling cabinet, compact size 600W×1000D×2000Hmm
  • KITOZER-CDU-50 integrated CDU with built-in pump set, heat exchanger and control system, no external cold source required
  • High-efficiency dry cooler supporting operation at -40℃~55℃ to maximize natural cooling utilization
  • Edge computing gateway supporting local data processing and remote management for edge computing scenarios

Implementation Effect:

  • Deployable in non-standard environments such as warehouses and workshops without professional computer rooms
  • Deployment time shortened to within 7 days to quickly respond to edge computing requirements
  • Support wide-temperature operation, reducing computer room construction costs by over 60%
  • Remote monitoring and management reduce manpower investment in operation and maintenance

10.2.3 Traditional Computer Room Renovation Solution

Solution Overview: Adopt cold plate liquid cooling cabinet + centralized CDU + existing cold source reuse to increase single cabinet power from 5kW to 40kW without changing computer room structure.

Core Configuration:

  • KITOZER-LC-CP42U cold plate liquid cooling cabinet compatible with existing 19-inch servers
  • KITOZER-CDU-120 centralized CDU, reusing existing chillers as cold sources
  • Quick connectors and flexible pipelines support online server replacement without business interruption
  • Liquid leakage detection system ensures computer room safety and prevents equipment damage from liquid leakage

Implementation Effect:

  • No large-scale computer room infrastructure transformation required, reducing renovation costs by 70%
  • Single cabinet power density increased to 40kW to meet new IT equipment deployment requirements
  • PUE reduced from 1.8 to 1.2 with annual power saving rate of 33%
  • Support online capacity expansion without affecting existing business operation

11. Product Application Cases

11.1 Case 1: AI Training Center of A Leading Internet Company

Project Background: The user built a new AI training center with 100 NVIDIA H100 GPU servers deployed, achieving single cabinet power density of 60kW, which cannot be met by traditional air cooling heat dissipation.

Solution: Adopt KITOZER immersion liquid cooling cabinet + distributed CDU + natural cooling system with target PUE of 1.08.

Deployment Scale: 100 sets of KITOZER-LC-IM48U immersion liquid cooling cabinets, 10 sets of KITOZER-CDU-200 distributed CDU, 5 sets of dry cooler systems.

Implementation Effect:

  • Single cabinet heat dissipation capacity reaches 60kW, fully meeting GPU server heat dissipation requirements
  • PUE stably maintained at 1.07, saving 4468 MWh of electricity annually, equivalent to the annual power consumption of 1500 households
  • Server failure rate reduced by 50% and maintenance costs decreased by 30%
  • Computer room space utilization increased by 60%, supporting rapid subsequent capacity expansion

11.2 Case 2: Core Database Center of A Financial Institution

Project Background: The user’s core database center faced capacity expansion bottlenecks. Traditional air cooling only supports 5kW single cabinet power, failing to meet the deployment requirements of new database clusters.

Solution: Adopt KITOZER cold plate liquid cooling cabinet + centralized CDU + existing cold source reuse to increase single cabinet power to 20kW without changing computer room structure.

Deployment Scale: 50 sets of KITOZER-LC-CP42U cold plate liquid cooling cabinets, 5 sets of KITOZER-CDU-120 centralized CDU, reusing existing chillers.

Implementation Effect:

  • Completed deployment within 30 days without transforming the computer room and affecting core business operation
  • Single cabinet power density increased to 20kW to support new database cluster deployment
  • PUE reduced from 1.7 to 1.2 with annual power saving rate of 29%
  • The liquid leakage detection system ensures core data security with zero safety accidents

11.3 Case 3: Industrial Internet Edge Node Project

Project Background: The user deployed industrial internet edge nodes in the factory, requiring 10 edge computing servers to be deployed in workshop environments without professional computer room conditions.

Solution: Adopt KITOZER cold plate liquid cooling cabinet + integrated CDU + dry cooler system to support wide-temperature environment operation.

Deployment Scale: 10 sets of KITOZER-LC-CP42U cold plate liquid cooling cabinets, 1 set of KITOZER-CDU-50 integrated CDU, 1 set of high-efficiency dry cooler.

Implementation Effect:

  • Successfully deployed in workshop environments without professional computer rooms, reducing construction costs by 80%
  • Support operation at -10℃~45℃, adapting to complex factory environments
  • Deployment completed in only 5 days to quickly respond to industrial internet construction requirements
  • Remote monitoring and management reduce manpower investment and operational costs

12. Search Keywords, SEO & Tags

12.1 Core Search Keywords

Intelligent liquid cooling cabinet, KITOZER liquid cooling cabinet, cold plate liquid cooling cabinet, immersion liquid cooling cabinet, spray liquid cooling cabinet, liquid cooling CDU, data center liquid cooling solution, AI computing center liquid cooling, edge data center liquid cooling, high-density computer room liquid cooling renovation, green data center solution, low PUE liquid cooling system, liquid cooling cabinet bid-winning parameters, liquid cooling cabinet application cases

12.2 SEO Optimization Guidelines

  1. Title Optimization: Include core keyword “KITOZER Intelligent Liquid Cooling Cabinet Solution” to highlight brand and core value.
  2. Content Optimization: Control core keyword density at 2%~5% and naturally integrate keywords into each chapter.
  3. Image Optimization: Add alt tags with core keywords for system schematic diagrams and product images.
  4. Structure Optimization: Adopt clear chapter structure and H3 heading tags to improve search engine readability.
  5. Link Optimization: Internal links point to relevant product pages, and external links cite authoritative industry reports and standards.

12.3 Tag Classification

Tag TypeTag Content
Product TypeIntelligent Liquid Cooling Cabinet, Liquid Cooling CDU, Cold Plate Liquid Cooling, Immersion Liquid Cooling, Spray Liquid Cooling
Application ScenarioAI Intelligent Computing Center, Edge Data Center, High-density Computer Room, Traditional Computer Room Renovation, Financial Data Center, Internet Data Center
Core AdvantagesLow PUE, High-efficiency Heat Dissipation, Intelligent Monitoring, Safety & Reliability, Rapid Deployment, Flexible Expansion
Technical FeaturesModular Design, Redundant Configuration, Natural Cooling, Liquid Leakage Detection, Remote Management
Industry StandardsISO9001, ISO14001, CE Certification, UL Certification, National First-class Energy Efficiency