Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32
KITOZER
KITOZER

KITOZER Computer Room Grounding Copper Foil

1. System Introduction

1.1 System Overview

The KITOZER computer room grounding copper foil system is an integrated lightning and static protection grounding solution specially designed for precision electronic equipment environments such as data centers, computer rooms, and communication base stations. Adopting high-purity electrolytic copper foil as the core conductive material, it builds an efficient, stable and low-impedance grounding network through scientific grid layout and equipotential bonding technology. The system realizes rapid discharge of lightning surges and effective dissipation of static charges, fully ensuring the operational safety of IT equipment.

1.2 Design Concepts & Principles

Compliant with national standards including GB 50174-2017 Code for Design of Data Centers and GB 50343-2012 Technical Code for Lightning Protection of Building Electronic Information Systems, the system adheres to the following design principles:

  • Combined Grounding: Working grounding, protective grounding, lightning protection grounding and anti-static grounding share one set of grounding devices, with grounding resistance ≤1Ω (Class A computer room) / ≤2Ω (Class B computer room).
  • Equipotential Bonding: Adopt M-type or S-type equipotential bonding to ensure potential balance of all metal components in the computer room and eliminate potential differences.
  • Low-Impedance Path: Copper foil grid design provides the shortest discharge path for lightning current and static charges, reducing grounding resistance and voltage drop.
  • Long-term Stability: High-corrosion-resistance pure copper material ensures long-term stable operation of the grounding system with a service life of ≥30 years.
data center surge protection solution (2)

1.3 System Functional Features

  1. Lightning Protection: Rapidly discharges lightning surge current, limits overvoltage at equipment terminals, and protects electronic devices from lightning damage.
  2. Static Electricity Prevention: Continuously dissipates human body static electricity and static charges generated by equipment operation to avoid electrostatic breakdown of electronic components.
  3. Electromagnetic Shielding: The copper foil grid forms a Faraday cage effect, effectively shielding external electromagnetic interference and improving equipment operation stability.
  4. Potential Equalization: Eliminates potential differences between different equipment and prevents equipment damage caused by ground potential counterattack.
  5. Signal Interference Suppression: Reduces ground loop interference and ensures the quality of communication and data transmission.

2. System Composition

System ModuleCore ComponentsFunction Description
Grounding Copper Foil NetworkKITOZER electrolytic copper foil (multiple specifications)Core conductor, forms grid-shaped grounding paths and undertakes main current discharge tasks
Equipotential Connection TerminalCopper equipotential connector, grounding busbarConnects copper foil and equipment grounding terminals to realize equipotential bonding
Grounding Lead-out DeviceCopper grounding lead-out wire, grounding terminal plateConnects the copper foil network to building grounding bodies or independent grounding electrodes
Fixing & Insulating AccessoriesConductive adhesive, copper foil tape, insulating fixing clipsEnsure reliable connection, firm fixation and insulation safety of copper foil
Anti-corrosion Protection ComponentsTinned copper connectors, anti-corrosion coating, sealantPrevents oxidation and corrosion of copper foil connections and extends service life
Testing & Monitoring DevicesGrounding resistance tester, equipotential test pointsUsed for system installation commissioning and daily maintenance detection
data center surge protection solution (4)

3. System Classification

3.1 Classification by Copper Foil Material

CategoryMaterial CharacteristicsApplicable Scenarios
Pure Copper Foil System≥99.99% purity electrolytic copper, conductivity ≥58MS/m, good flexibilityHigh-precision computer rooms, Class A data centers, scenarios with ultra-high conductivity requirements
Tinned Copper Foil SystemPure copper base with tin plating on surface, enhanced anti-corrosion performanceComputer rooms in humid and coastal areas, scenarios requiring long-term operational stability
Composite Copper Foil SystemComposite structure of copper foil + insulating back adhesive + conductive adhesive, convenient constructionRenovation projects, rapid deployment scenarios, computer rooms with high installation efficiency requirements

3.2 Classification by Grid Structure

CategoryStructural CharacteristicsApplicable Scenarios
M-type Grid SystemCopper foil crosses vertically and horizontally to form grids of 500mm×500mm ~ 2000mm×2000mmLarge-area computer rooms and open layouts, suitable for S-type equipotential bonding
S-type Single-point SystemRadial copper foil layout centered on grounding busbarSmall computer rooms and centralized cabinet layouts, suitable for single-point grounding
Ring + Grid Composite SystemCombination of peripheral ring copper foil and internal grid copper foilKey computer rooms and high-security-level scenarios with dual grounding guarantee

3.3 Classification by Application Scenario

  1. Data Center Dedicated Type: Designed for large-scale data centers, copper foil thickness ≥0.2mm, grid spacing ≤1m×1m, meeting Class A computer room standards.
  2. Communication Computer Room Type: Suitable for communication base stations and switching rooms, copper foil width ≥80mm, focusing on lightning and static protection for communication equipment.
  3. Industrial Control Computer Room Type: Strong anti-interference capability, combined copper foil and shielding layer, applicable to industrial automation control centers.
  4. Medical Equipment Computer Room Type: Low-impedance design with grounding resistance ≤0.5Ω, meeting high-precision operation requirements of medical equipment.
  5. Renovation & Upgrade Type: Ultra-thin copper foil (thickness ≤0.1mm), suitable for existing computer room renovation without large-scale construction.

4. System Configuration List (Brand: KITOZER)

4.1 Standard Configuration List (100㎡ Computer Room)

No.Product NameSpecification ModelQuantityUnitRemarks
1High-purity Electrolytic Copper FoilKT-CF-100-0.2 (100mm×0.2mm)400MeterPurity ≥99.99%, conductivity ≥58MS/m
2Copper Foil Conductive AdhesiveKT-CA-5020PieceVolume resistivity ≤0.01Ω·cm, curing time ≤24h
3Equipotential BusbarKT-BUS-50×5 (50mm×5mm red copper)4MeterFor equipotential connection around the computer room
4Cabinet Grounding TerminalKT-GT-1630PieceCompatible with 16mm² grounding wire, tinned copper
5Grounding Lead-out WireKT-GL-35 (35mm² stranded copper wire)10MeterConnects copper foil network and building grounding body
6Copper Foil Fixing ClipKT-FC-100200PieceInsulating material, fixed at spacing ≤500mm
7Tinned Copper ConnectorKT-CJ-10050PieceFor copper foil cross connection with anti-corrosion treatment
8Insulating SealantKT-IS-5010PieceSeals and moisture-proofs copper foil connections
9Equipotential Test PointKT-TP-018PieceConvenient for system detection with nameplate
10Construction Tool SetKT-TK-011SetIncluding copper foil cutting, crimping and testing tools

4.2 Custom Configuration Options

Customized configurations are available according to computer room scale, equipment density and safety level:

  1. Copper Foil Specification Customization: Width 50mm~300mm, thickness 0.05mm~0.5mm to meet different current carrying requirements.
  2. Grid Spacing Adjustment: Standard spacing 1m×1m, customizable 0.5m×0.5m (high-density equipment area) or 2m×2m (open area).
  3. Special Environment Accessories: High-temperature resistant copper foil (-50℃~150℃), waterproof copper foil, flame-retardant copper foil, etc.
  4. Intelligent Monitoring Upgrade: Optional online grounding resistance monitoring module to monitor grounding system status in real time.
data center surge protection solution (6)

5. System Schematic Diagram

5.1 System Architecture Schematic

Plain Text
┌─────────────────────────────────────────┐
│        Computer Room Building Grounding Body / Grounding Electrode        │
└───────────────────┬─────────────────────┘
                    │
        ┌───────────▼───────────┐
        │     Grounding Lead-out Terminal Board     │
        └───────────┬───────────┘
                    │
        ┌───────────▼───────────┐
        │   Peripheral Main Copper Foil (300mm Width)   │
        └───────────┬───────────┘
                    │
┌───────────────────┴───────────────────┐
│  Grid Copper Foil Network (100mm Width, 1m×1m Spacing)  │
└───────────┬───────────────────┬───────┘
            │                   │
    ┌───────▼───────┐     ┌─────▼─────┐
    │ Cabinet Grounding Terminal │     │ Equipment Grounding Terminal │
    └───────┬───────┘     └─────┬─────┘
            │                   │
    ┌───────▼───────┐     ┌─────▼─────┐
    │ Server / Switch │     │ Precision Instrument │
    └───────────────┘     └───────────┘

5.2 Equipotential Bonding Schematic

Plain Text
Copper Foil Grid ────┬─── Conductive Adhesive Connection ────┬─── Equipotential Busbar ────┬─── Grounding Lead-out Wire ──── Building Grounding Body
                     │                                   │                                   │
                     ├─── Cabinet Grounding ──────────────┤                                   │
                     │                                   │                                   │
                     ├─── Raised Floor Bracket ───────────┤                                   │
                     │                                   │                                   │
                     └─── Metal Cable Trunking ───────────┘                                   │
                                                                                             │
                                                                                             └─── Other Grounding Devices (UPS, Air Conditioner)

5.3 Copper Foil Cross Connection Schematic

Plain Text
┌─────────────┐        ┌─────────────┐
│ Horizontal Copper Foil    │        │ Vertical Copper Foil    │
│ (100mm Width)   │        │ (100mm Width)   │
└───────┬─────┘        └─────┬───────┘
        │                     │
        └─────────┬─────────┘
                  │
        ┌─────────▼─────────┐
        │ Tinned Copper Connector + Conductive Adhesive  │
        │ (Cross Point Processing)       │
        └───────────────────┘

6. Product Technical Parameters

6.1 Core Parameters of KITOZER Grounding Copper Foil

Parameter ItemTechnical IndexTest Standard
Material Purity≥99.99% electrolytic copperGB/T 5231-2021
Thickness Specification0.05mm/0.1mm/0.2mm/0.3mm/0.5mm, tolerance ±0.02mm—
Width Specification50mm/80mm/100mm/150mm/200mm/300mm, tolerance ±0.5mm—
Conductivity≥58MS/mGB/T 3048.2-2023
Sheet Resistance≤0.015Ω/□ (0.2mm thickness)ASTM D257
Tensile Strength≥200N/mm²GB/T 228.1-2021
Elongation≥30%GB/T 228.1-2021
Temperature Resistance Range-50℃~150℃, no embrittlement or cracking—
Corrosion ResistanceSalt spray test ≥1000 hoursGB/T 10125-2021
Insulation PerformanceBack insulating layer breakdown voltage ≥10kVGB/T 1408.1-2016

6.2 Supporting Component Technical Parameters

Component NameKey ParametersPerformance Index
Conductive AdhesiveVolume Resistivity≤0.01Ω·cm, no flowing after curing
Equipotential ConnectorContact Resistance≤0.001Ω, plugging life ≥1000 times
Grounding BusbarMaterial / SizePure copper, thickness ≥5mm, width ≥50mm
Tinned Copper ConnectorTin Plating Thickness≥5μm, consistent conductivity with pure copper
Copper Foil Fixing ClipInsulation Resistance / Flame RetardancyInsulation resistance ≥10¹⁰Ω, V0 flame retardant grade
Grounding Lead-out WireConductor Cross-sectional Area16mm²/25mm²/35mm², stranded copper core
data center surge protection solution (8)

7. Product Application Scope

7.1 Core Application Scenarios

  1. Data Center Computer Rooms: Class A/B/C data centers, cloud computing centers, server cluster computer rooms.
  2. Communication Computer Rooms: Telecommunication rooms, mobile base stations, unicom rooms, radio and television transmitting rooms.
  3. Financial Institution Computer Rooms: Bank data centers, securities trading system rooms, insurance core business rooms.
  4. Government & Enterprise Computer Rooms: Government cloud rooms, enterprise private clouds, industrial control rooms.
  5. Medical Equipment Computer Rooms: Hospital imaging centers, precision medical equipment control rooms, laboratories.

7.2 Special Application Environments

  1. High Static Risk Areas: Electronic production workshops, semiconductor clean rooms, precision instrument laboratories.
  2. Strong Electromagnetic Interference Environments: Radar stations, satellite ground stations, power dispatching centers.
  3. Humid / Corrosive Environments: Coastal computer rooms, underground computer rooms, chemical enterprise computer rooms.
  4. Renovation & Upgrade Projects: Old computer room grounding system renovation, new equipment grounding expansion.
  5. Mobile Computer Rooms: Container data centers, modular computer rooms, temporary computer rooms.
data center surge protection solution (9)

8. Product Advantages

8.1 Performance Advantages

  1. Ultra-low Impedance: High-purity copper foil material with grounding resistance ≤0.5Ω, far exceeding national standard requirements.
  2. Fast Current Discharge: Large copper foil surface area enables lightning current discharge speed 3-5 times faster than traditional flat steel.
  3. Potential Equalization: Grid design ensures indoor potential difference ≤0.1V, effectively preventing ground potential counterattack.
  4. Electromagnetic Shielding: Copper foil grid forms a Faraday cage with shielding efficiency ≥60dB (10kHz~1GHz).
  5. Strong Weather Resistance: Stable operation in -50℃~150℃ temperature range, adapting to various extreme environments.

8.2 Construction & O&M Advantages

  1. Lightweight Design: Copper foil thickness only 0.2mm, lighter than traditional copper bars/flat steel, reducing building load-bearing requirements.
  2. Convenient Construction: Good flexibility for bending and laying, adapting to complex ground conditions, improving construction efficiency by 50%.
  3. Space Saving: Ultra-thin design occupies no floor height, especially suitable for low-floor-height computer rooms.
  4. Simple Maintenance: Welding-free connection technology facilitates later expansion and maintenance, reducing O&M costs.
  5. Environmental Safety: No heavy metal pollution, RoHS compliant and recyclable.

8.3 Economic Advantages

  1. High Cost Performance: 30% lower cost and 20% higher performance compared with copper bar solutions.
  2. Long Service Life: ≥30-year service life, reducing replacement frequency and maintenance costs.
  3. Energy Saving Effect: Low-impedance characteristic reduces power loss and saves long-term electricity costs.
  4. Risk Reduction: Reduces equipment damage risks and losses caused by data loss and business interruption.

9. Bid-winning Control Parameters

9.1 Core Bid Control Indicators

  1. Material Requirement: Grounding copper foil must adopt ≥99.99% purity electrolytic copper, complying with GB/T 5231-2021 standard.
  2. Size Specification: Thickness ≥0.2mm, width ≥100mm, sheet resistance ≤0.015Ω/□.
  3. Conductivity: ≥58MS/m, complying with IEC international standards.
  4. Equipotential Bonding: Copper foil cross connections must adopt tinned copper connectors + conductive adhesive treatment with contact resistance ≤0.001Ω.
  5. Grounding Resistance: Combined grounding system resistance ≤1Ω (Class A) / ≤2Ω (Class B), complying with GB 50174-2017.
  6. Service Life: ≥30 years, no corrosion after 1000-hour salt spray test.
  7. Construction Technology: Welding-free construction supported, copper foil fixed at spacing ≤500mm with insulation protection.
  8. Brand Requirement: Original KITOZER products with manufacturer authorization and quality test reports.

9.2 Technical Response Key Points

  1. Provide complete grounding system design scheme, including copper foil grid layout drawing, equipotential connection drawing and grounding resistance calculation document.
  2. Provide third-party product test reports covering key indicators such as material purity, conductivity and sheet resistance.
  3. Provide construction organization design scheme including construction process, quality control measures and safety guarantee plan.
  4. Provide after-sales service commitment including 2-year warranty, lifelong maintenance and regular inspection services.
  5. Provide successful cases of similar projects with user evaluation and acceptance reports.

10. Product Solution

10.1 Solution Design Process

  1. Demand Analysis: Clarify computer room type, equipment quantity, safety level, geological conditions and other basic information.
  2. On-site Investigation: Measure computer room area, ground condition, existing grounding system and soil resistivity.
  3. Scheme Design: Design copper foil grid layout, equipotential bonding mode and grounding lead-out scheme based on investigation results.
  4. Simulation Calculation: Use professional software to calculate key indicators including grounding resistance, lightning current distribution and potential difference.
  5. Scheme Optimization: Adjust copper foil specifications, grid spacing and connection modes according to calculation results to meet standard requirements.
  6. Construction Design: Formulate detailed construction drawings, material lists, construction processes and quality control standards.

10.2 Standard Construction Steps

  1. Ground Pre-treatment: Clean and repair the ground to ensure flat and dry surface.
  2. Layout & Positioning: Mark copper foil laying lines and confirm grid crossing points and connection points per design drawings.
  3. Copper Foil Laying: Lay copper foil along the lines to ensure flatness without folds or damage.
  4. Cross Connection: Connect copper foil crossing points with tinned copper connectors and conductive adhesive for reliable contact.
  5. Equipotential Bonding: Install equipotential busbars and connect copper foil with cabinet and equipment grounding terminals.
  6. Grounding Lead-out: Connect the copper foil network to building grounding bodies or independent grounding electrodes via grounding lead-out wires.
  7. Insulation Treatment: Insulate non-connecting parts of copper foil to prevent short circuit and electric shock risks.
  8. Testing & Acceptance: Test grounding resistance and equipotential bonding effect to meet design requirements.
  9. Marking & Recording: Mark key system parts, record test data and form acceptance reports.

10.3 Quality Control Key Points

  1. Material Inspection: All copper foil and accessories must have original KITOZER marks and quality certificates.
  2. Connection Quality: Connection contact resistance ≤0.001Ω, tested by micro-ohmmeter.
  3. Laying Specification: Flat copper foil without folds, fixed spacing ≤500mm with firm connections.
  4. Grounding Resistance: Combined grounding system resistance ≤1Ω, independent grounding system ≤4Ω.
  5. Equipotential Test: Potential difference between any two points in the computer room ≤0.1V to ensure equipotential effect.
  6. Insulation Performance: Insulation resistance between copper foil and non-grounded metal parts ≥10⁶Ω to prevent electric leakage.

10.4 Operation & Maintenance Management Solution

  1. Regular Detection: Conduct at least one comprehensive inspection annually to test grounding resistance and equipotential bonding effect.
  2. Daily Inspection: Regularly check copper foil for damage and connection points for looseness and corrosion.
  3. Maintenance Recording: Establish complete maintenance files to record test data, maintenance contents and replaced parts.
  4. Fault Handling: Timely troubleshoot abnormal grounding resistance rise and loose connections.
  5. Expansion Management: Expand the grounding system per original standards for new equipment to ensure system integrity.

11. Product Application Cases

11.1 Case 1: XX Bank Head Office Data Center (Class A Computer Room)

Project Overview: Building area 5000㎡, accommodating more than 2000 servers, designed grounding resistance ≤0.5Ω.

Solution: Adopt KITOZER 0.2mm×150mm pure copper foil with 0.8m×0.8m grid spacing and M-type equipotential bonding.

Implementation Effect:

  • Measured grounding resistance: 0.38Ω, far better than design requirements.
  • Lightning current discharge time: ≤1μs, compliant with GB 50343-2012 standard.
  • Maximum indoor potential difference ≤0.08V, effectively preventing ground potential counterattack.
  • 3-year stable operation without any equipment damage caused by lightning or static electricity.

11.2 Case 2: XX Telecom 5G Core Network Computer Room

Project Overview: Modular computer room with 800㎡ area in strong electromagnetic interference environment.

Solution: Adopt KITOZER 0.3mm×200mm tinned copper foil with ring + grid composite structure for integrated shielding and grounding.

Implementation Effect:

  • Electromagnetic shielding efficiency ≥70dB (10kHz~1GHz), effectively reducing external interference.
  • Grounding resistance 0.42Ω, meeting high requirements of communication computer rooms.
  • No corrosion on copper foil surface after salt spray test with excellent durability.
  • Welding-free connection design facilitates later equipment expansion and maintenance.

11.3 Case 3: XX Hospital Imaging Center Computer Room

Project Overview: Underground computer room in humid environment, precision medical equipment sensitive to static electricity and electromagnetic interference.

Solution: Adopt KITOZER 0.2mm×100mm composite copper foil (with insulating back adhesive) and M-type grid design, grounding resistance ≤0.5Ω.

Implementation Effect:

  • Static voltage ≤50V during human-equipment contact, zero equipment damage cases caused by static electricity.
  • Effectively shields electromagnetic interference from MRI, CT and other equipment to ensure normal operation of other devices.
  • Waterproof composite copper foil design prevents moisture damage during long-term operation.
  • Zero safety accidents after 2-year stable system operation.

12. SEO Keywords & Tags

12.1 Search Keywords

Computer room grounding copper foil, KITOZER grounding copper foil, computer room lightning protection grounding, data center grounding system, equipotential bonding, anti-static grounding, lightning protection grounding solution, copper foil grounding grid, computer room grounding renovation, Class A computer room grounding standard

12.2 SEO Optimization Tags

  • Main Tags: Computer Room Grounding Copper Foil, KITOZER, Lightning Protection Grounding, Data Center
  • Secondary Tags: Equipotential Bonding, Static Prevention, Grounding System, Copper Foil Grounding Grid, Computer Room Renovation
  • Technical Tags: GB 50174-2017, GB 50343-2012, Grounding Resistance, Lightning Current Discharge
  • Application Tags: Data Center Room, Communication Room, Financial Room, Medical Room, Modular Room
  • Advantage Tags: Low Impedance, Fast Discharge, Potential Equalization, Electromagnetic Shielding, Convenient Construction