Table of Contents
Toggle1. System Introduction
The KITOZER fiber splicing accessories system is a full-link fiber splicing solution specially designed for modern data centers, cloud computing centers, enterprise computer rooms and communication hubs. It covers the complete workflow including fiber preprocessing, splicing, protection and link management. Adopting high-precision and highly reliable components, the system features low splicing loss, superior stability and long service life. It supports high-speed optical transmission from 10G to 800G, serving as the core foundation for building high-performance and high-availability optical communication networks.
Compliant with international standards (IEC, TIA/EIA) and domestic telecommunication specifications, the system is compatible with single-mode, multi-mode, ribbon fibers and various cable structures such as stranded loose tube, central loose tube, slotted core and ribbon cables. It can be flexibly deployed in computer rooms of all scales, including new cabling projects, renovation and upgrade of existing rooms, and fiber link maintenance.

2. System Composition
The KITOZER fiber splicing accessories system consists of five core modules that work collaboratively to realize full-process management of fiber splicing.
| Module Name | Core Components | Function Description |
|---|---|---|
| Splicing Equipment Module | Fiber fusion splicer, fiber cleaver, electrode rods | Achieve precise fiber alignment and splicing, deliver stable arc heating, and ensure splicing loss below 0.05dB |
| Splicing Consumables Module | Heat shrink sleeves, splice trays, fiber protection tubes | Protect splice points, provide space for fiber coiling and storage, and enhance mechanical strength of splices |
| Fiber Termination Module | Fiber termination boxes, ODF units, adapters | Connect fibers with equipment ports, and realize fiber fixation, splicing, distribution and wiring management |
| Fiber Preprocessing Tools | Fiber strippers, cleaning tools, fiber clamps | Remove fiber coating and clean fiber surface to guarantee qualified end face quality |
| Testing & Maintenance Module | Optical power meter, visual fault locator, OTDR accessories | Verify splicing quality, check integrity of fiber links and locate fault points |
3. System Classification
3.1 Classification by Splicing Type
| Category | Application Scenarios | Core Components | Features |
|---|---|---|---|
| Single Fiber Splicing System | Conventional computer room cabling, FTTH access, branch links | Single-core fusion splicer, single-core splice tray | Splice one fiber at a time with high precision and low loss (≤0.02dB); widely used in general scenarios |
| Ribbon Fiber Splicing System | High-density data centers, backbone networks, large-scale computer rooms | Ribbon fusion splicer, ribbon splice tray | Splice 4 to 12 fibers at once with high efficiency; cut working time by over 50% for mass splicing |
| Drop Cable Splicing System | Building cabling, indoor computer rooms, FTTH home access | Special drop cable splicer, drop cable clamps | Compatible with figure-8 drop cables; 3-in-1 clamp fits various drop cable specifications |
| Special Fiber Splicing System | High-speed links in data centers, scientific research institutions | Polarization-maintaining fiber splicer, special fiber clamps | Adapt to polarization-maintaining fibers and photonic crystal fibers to meet high-precision transmission requirements |

3.2 Classification by Computer Room Scale
- Small Computer Room Splicing System (≤200 cores) Applicable to enterprise branch computer rooms and edge computing nodes. Equipped with basic splicing tools and compact termination boxes for high cost performance.
- Medium Computer Room Splicing System (200-1000 cores) Applicable to medium-sized data centers and enterprise headquarters computer rooms. Configured with high-efficiency splicing devices and high-density ODF units, supporting modular expansion.
- Large Computer Room Splicing System (≥1000 cores) Applicable to cloud computing centers and hyperscale data centers. Equipped with ribbon splicing equipment, high-density ODF racks and intelligent management systems, supporting 400G/800G high-speed optical transmission.
3.3 Classification by Deployment Mode
- Rack-mounted Splicing System Fits standard 19-inch cabinets. ODF units and splice trays are rack-installed to save space and facilitate centralized management.
- Wall-mounted Splicing System Ideal for space-limited computer rooms. Termination boxes and splicing devices are wall-mounted to make full use of wall space flexibly.
- Portable Splicing System Designed for on-site maintenance and emergency repair. Comes with portable splicers and tool kits for rapid field splicing.

4. System Configuration List (KITOZER)
4.1 Splicing Equipment
| Product Name | Model | Specification | Quantity | Purpose |
|---|---|---|---|---|
| Fiber Fusion Splicer | KT-8600 | 6-motor drive, 480x magnification, 8s splicing time, 18s heating time | 1 Set | Core device for precise fiber alignment and splicing |
| Fiber Cleaver | KT-320 | High-precision blade, cutting angle ≤0.5°, service life ≥40,000 cuts | 1 Piece | Fabricate smooth fiber end faces |
| Electrode Rod | KT-ELC20 | Tungsten steel material, compatible with KT-8600 | 2 Pairs | Generate electric arc as heat source for splicing |
| 3-in-1 Fiber Clamp | KT-CLAMP3 | Compatible with φ0.25mm/φ0.9mm/φ3.0mm fibers | 2 Pieces | Fix fibers of different sizes to ensure splicing accuracy |
4.2 Splicing Consumables
| Product Name | Model | Specification | Quantity | Purpose |
|---|---|---|---|---|
| Fiber Heat Shrink Sleeve | KT-TS06 | 60mm/80mm/100mm, low shrinkage rate | 100 Pcs | Protect splice points and improve mechanical strength |
| Splice Tray | KT-SP12 | 12-core, compatible with FC/SC/LC/ST adapters | 10 Pcs | For fiber splicing, coiling, storage and hierarchical management |
| Fiber Protection Tube | KT-PT10 | φ10mm, corrugated structure, bending radius ≥45mm | 20 Meters | Prevent fibers from mechanical damage |
| Fiber Cleaning Wipes | KT-CL01 | Lint-free, 99.9% cleaning efficiency | 5 Packs | Remove oil and dust from fiber end faces |
4.3 Termination & Management Products
| Product Name | Model | Specification | Quantity | Purpose |
|---|---|---|---|---|
| Fiber Termination Box | KT-OTB24 | 24-port, rack/wall mount, IP65 protection | 2 Pcs | Fiber fixation, splicing and distribution for indoor and outdoor environments |
| ODF Unit | KT-ODF48 | 48-port, 19-inch rack mount, high density | 1 Pc | Manage main fiber links in large data centers |
| LC/SC Adapter | KT-AD-LC / KT-AD-SC | Single-mode/Multi-mode, insertion loss ≤0.2dB | 50 Pcs | Connect fibers with equipment ports, support hot swapping |
| Fiber Patch Cord | KT-JUMP-LC | LC-LC, OS2 single-mode / OM4 multi-mode | 20 Pcs | Transmit optical signals between devices for high-speed networks |
4.4 Preprocessing & Testing Tools
| Product Name | Model | Specification | Quantity | Purpose |
|---|---|---|---|---|
| Fiber Stripper | KT-ST03 | 3-section design, for 250μm/900μm coating | 1 Pc | Strip fiber coating completely |
| Fiber Cleaning Pen | KT-CP01 | Replaceable cleaning head, 99% dust removal rate | 2 Pcs | Clean connector end faces to optimize transmission performance |
| Visual Fault Locator | KT-RL30 | 30mW, visible distance ≥5km | 1 Pc | Detect fiber breaks and verify link connectivity |
| Optical Power Meter | KT-PM50 | Wavelength: 850/1300/1310/1550nm | 1 Pc | Measure optical power and evaluate splicing loss |

5. System Schematic Diagrams
5.1 Fiber Splicing Workflow
Optical Cable → Stripping → Fixing → Coating Removal → Cleaning → Cleaving → Splicing → Heat Shrink Protection → Fiber Coiling → Termination → Testing → Link Completion
│ │ │ │ │ │ │ │ │
└──Cable Preprocessing──┘ └─End Face Preparation─┘ └─Splicing & Protection─┘ └─Fiber Management & Testing─┘
5.3 Splicing Loss Control Principle
The KITOZER system realizes low-loss splicing via the following technologies:
- Precise alignment with 4-motor control: Dual X/Y axis adjustment, core offset < 0.5μm
- Stable arc control: Closed-loop feedback system, arc intensity deviation < ±5%
- High-definition imaging: 480x magnification for real-time splicing monitoring
- Intelligent algorithm: Automatically identify fiber types and match optimal parameters
- Uniform heating: Constant temperature ensures bubble-free shrinkage of heat sleeves
6. Technical Parameters
6.1 Core Splicing Device (KT-8600 Fiber Fusion Splicer)
| Category | Item | Technical Index |
|---|---|---|
| Splicing Performance | Average Splicing Loss | SM: ≤0.02dB; MM: ≤0.01dB; Ribbon Fiber: ≤0.03dB per core |
| Splicing Time | SM: 8s; MM: 6s; Ribbon: 12s | |
| Heating Time | 18s (for standard heat shrink sleeves) | |
| Return Loss | ≥60dB | |
| Mechanical Performance | Tensile Strength of Splice | ≥1.8N (Standard: 1.5N) |
| Electrode Service Life | ≥3,000 splices | |
| Battery Capacity | Rechargeable lithium battery, ≥200 continuous splices & heating cycles | |
| Environmental Adaptability | Operating Temperature | -10℃ ~ +50℃ |
| Storage Temperature | -40℃ ~ +80℃ | |
| Humidity | 0~95% (Non-condensing) | |
| Vibration Resistance | Compliant with IEC 60068-2-6 |
6.2 Splicing Consumables (KT-TS06 Heat Shrink Sleeve)
| Parameter | Index | Test Standard |
|---|---|---|
| Inner Diameter | 2.0mm / 3.0mm | IEC 60794-1 |
| Wall Thickness | 0.4mm | IEC 60794-1 |
| Shrink Ratio | 2:1 | IEC 60794-1 |
| Shrink Temperature | 120℃ ~ 140℃ | IEC 60794-1 |
| Dielectric Strength | ≥15kV/mm | IEC 60243 |
| Tensile Strength | ≥12MPa | IEC 60811-1-1 |
| Thermal Aging Resistance | No crack after 168h at 120℃ | IEC 60811-3-1 |
6.3 Termination Component (KT-ODF48 Unit)
| Parameter | Index | Description |
|---|---|---|
| Port Density | 48 ports (LC duplex) | Fits standard 19-inch cabinet |
| Insertion Loss | ≤0.2dB | Compliant with TIA/EIA-568 |
| Return Loss | ≥50dB (SM) / ≥30dB (MM) | Compliant with TIA/EIA-568 |
| Dielectric Strength | ≥3kV DC / 1min, no breakdown | GB/T 14733.10 |
| Insulation Resistance | ≥1000MΩ @ 500V DC | GB/T 14733.10 |
| Mechanical Durability | ≥1000 mating cycles | GB/T 14733.10 |
| Operating Temperature | -40℃ ~ +85℃ | Adapt to varying computer room temperatures |
7. Application Scope
7.1 Data Centers & Cloud Computing Centers
- Support 400G/800G high-speed optical transmission for AI computing clusters and distributed storage systems
- High-density ODF units improve cabinet utilization and reduce PUE
- Realize splicing for main and branch links to support massive data interaction
7.2 Enterprise & Government Computer Rooms
- Provide optical connections between server clusters and network devices to ensure business continuity
- Compatible with new and old equipment for smooth room renovation and upgrade
- Connect branch rooms with headquarters to build enterprise-level optical networks
7.3 Telecom Operator Rooms
- Splicing for core nodes of backbone and metropolitan area networks for long-distance & large-capacity transmission
- Serve convergence nodes of 5G core and access networks to meet high-bandwidth demands
- Support Data Center Interconnection (DCI) for cross-regional data synchronization and backup
7.4 Special Industry Applications
- Finance: Low-latency links to guarantee real-time trading systems
- Medical: High-reliability connections for telemedicine and medical image transmission
- Energy: Industrial-grade protection for harsh environments in power and petroleum industries
- Education & Research: Support special fiber splicing for scientific experiments
8. Product Advantages
8.1 Technical Advantages
- Ultra-low splicing loss: Average loss ≤0.02dB, much better than the industry standard of 0.05dB, extending transmission distance
- High-precision alignment: 6-motor drive, alignment accuracy up to 0.1μm for stable splicing quality
- Intelligent algorithm: Auto-identify fiber types and match optimal parameters to lower operation difficulty
- Fast processing: 8s for single-mode splicing and 18s for heating, boosting construction efficiency by over 50%
8.2 Reliability Advantages
- Industrial protection: Splicer with IP52 rating for complex computer room environments
- Long service life: Electrodes for ≥3,000 splices, cleavers for ≥40,000 cuts to cut maintenance costs
- Multiple protection: Over-current, over-voltage and over-temperature protection to avoid device damage
- Wide compatibility: Support all mainstream fiber types and cable structures
8.3 Management Advantages
- Modular design: Standardized components for easy replacement and upgrade
- Hierarchical layout: Clear fiber routing via splice trays and ODF units for simple maintenance
- Traceability: Splicing data can be stored and exported for quality tracking and troubleshooting
- Space saving: High-density design improves cabinet utilization
8.4 Cost Advantages
- High efficiency: Automatic splicing and heating reduce labor hours and construction costs
- Low loss: Minimize the use of optical amplifiers and cut network investment
- Long lifespan: Service life over 10 years to reduce replacement frequency
- Easy maintenance: Modular structure and clear labels save maintenance time and cost
9. Bid Control Parameters
9.1 Core Equipment Parameters
| Product Name | Control Item | Requirement |
|---|---|---|
| Fiber Fusion Splicer | Splicing Loss | SM ≤0.02dB, MM ≤0.01dB, Ribbon ≤0.03dB per core |
| Alignment Mode | 6-motor drive, X/Y dual-axis adjustment, core offset < 0.5μm | |
| Imaging System | 480x magnification, dual-camera real-time monitoring | |
| Splicing Time | SM ≤8s, MM ≤6s, Ribbon ≤12s | |
| Electrode Life | ≥3,000 splices | |
| Fiber Cleaver | Cutting Angle | ≤0.5° |
| Blade Life | ≥40,000 cuts | |
| Compatible Fibers | 250μm/900μm/3.0mm / drop cables |
9.2 Splicing Consumables Parameters
| Product Name | Control Item | Requirement |
|---|---|---|
| Heat Shrink Sleeve | Shrink Temperature | 120℃~140℃, uniform shrinkage without bubbles |
| Mechanical Strength | Tensile strength of protected splice ≥1.8N | |
| Compatibility | Fit single-mode, multi-mode and ribbon fibers | |
| Splice Tray | Fiber Capacity | 12/24 cores, support FC/SC/LC/ST adapters |
| Bending Radius | ≥45mm, complying with fiber minimum bending radius standard | |
| Insulation Resistance | ≥1000MΩ @ 500V DC |
9.3 Overall System Requirements
- Compatibility: Support SM (OS1/OS2), MM (OM1~OM5) and 4-12 core ribbon fibers
- Environment: Operating temperature -10℃~+50℃, humidity 0~95% (non-condensing)
- Certification: CE, FCC, RoHS certified and compliant with telecommunication standards
- Warranty: Minimum 3-year overall warranty, 5-year technical support for splicers
- After-sales: 24-hour response, on-site service within 48 hours and spare device support
10. Solutions
10.1 Solution for Small Computer Rooms (≤200 Cores)
Application: Enterprise branch rooms, small data centers, edge computing nodes
Features:
- Adopt KT-8600 single-core splicer and KT-320 cleaver for general splicing work
- Equip 12-core splice trays and 24-port termination boxes for basic link management
- Portable design for mobile construction and maintenance
- Cost-effective for budget-limited projects
Implementation Steps:
- Site planning: Confirm cable routes and working space
- Cable laying: Follow specifications to ensure bending radius ≥45mm
- Splicing construction: Operate with standard workflow
- Termination: Fix and distribute fibers via KT-OTB24
- Acceptance test: Use optical power meter and visual fault locator to verify link quality
10.2 Solution for Medium Computer Rooms (200-1000 Cores)
Application: Enterprise headquarters rooms, medium data centers, cloud computing nodes
Features:
- Combine KT-8600 single-core and KT-8800 ribbon splicers to improve efficiency
- Deploy 48-port ODF units and 24-core splice trays for high-density management
- Modular structure supports smooth expansion
- Hierarchical layout for clear routing and easy maintenance
Implementation Steps:
- BIM routing design to cut redundant cables by 30%
- Main link: Use ribbon splicer for 12-core simultaneous splicing
- Branch link: Use single-core splicer to guarantee quality
- Centralized management via KT-ODF48
- Data storage for link quality tracking
10.3 Solution for Large Data Centers (≥1000 Cores)
Application: Hyperscale data centers, cloud computing centers, internet enterprise rooms
Features:
- KT-9000 multi-core splicer for 16-core simultaneous splicing and high efficiency
- 1152-core high-density ODF racks for 400G/800G transmission
- Compatible with MPO pre-terminated system for rapid deployment
- Intelligent platform for real-time quality and status monitoring
Implementation Steps:
- Full-link planning for main, branch and equipment links
- High-density splicing for ribbon cables and MPO links
- Combine pre-terminated cables with field splicing to shorten construction period
- Three-level management: Main ODF + Zone ODF + Equipment ODF
- Full OTDR testing to control splicing loss ≤0.02dB
10.4 Solution for Computer Room Renovation & Upgrade
Application: Old room renovation, network upgrade, fiber link expansion
Features:
- Compatible with existing cables and devices for smooth migration
- Portable tool kit suitable for narrow working spaces
- Support live splicing to minimize service interruption
- Optimize routing to improve space utilization
Implementation Steps:
- Condition assessment and renovation plan formulation
- Zonal construction to avoid full-service outage
- Live splicing with service interruption limited within 30 minutes
- Interconnect new and old devices via KT-AD series adapters
- Comprehensive testing after renovation
11. Project Cases
11.1 Case 1: Hyperscale Data Center in Guangzhou
Background: A cloud computing provider’s data center with 10,000 cabinets, deployed with 400G high-speed optical network, total splicing capacity of 50,000 cores.
Solution:
- KT-9000 multi-core splicer (16 cores at a time), efficiency increased by 60%
- 1152-core high-density ODF racks, space utilization improved by 30%
- Hierarchical splicing for ribbon main cables and single-mode branch cables
- Splicing loss controlled below 0.01dB to meet 400G transmission requirements
Effect:
- Construction period shortened by 40%, project completed 15 days in advance
- Link stability greatly improved, failure rate reduced by 90%
- PUE decreased by 0.05; compatible with future 800G upgrade
11.2 Case 2: Financial Institution Room Renovation in Shenzhen
Background: Upgrade from 10G to 100G network, add 200 servers, total 1,200 cores. Service interruption required ≤2 hours.
Solution:
- KT-8600 splicer and portable tools for live splicing
- 48-port ODF units for integrated management of new and old links
- Phased splicing and fast switching, single-phase work ≤10 minutes
- Splicing data storage for traceability
Effect:
- Actual service interruption: 1.5 hours
- Average splicing loss: 0.015dB, fully supporting 100G network
- Zero data loss during migration; maintenance efficiency increased by 50%
11.3 Case 3: 5G Core Network Room of Operator in Beijing
Background: 5G core network construction with 2,000 fiber cores, requiring high efficiency and stability.
Solution:
- KT-8800 ribbon splicer (12 cores at a time), efficiency increased by 50%
- 288-core ODF units for centralized scheduling
- Real-time splicing monitoring and remote data upload
Effect:
- Daily splicing capacity up to 320 cores, first-pass success rate 99.7%
- Stable operation of 5G core network supporting millions of users
- Maintenance cost reduced by 40%, fault response time shortened by 50%
12. Keywords & Tags
12.1 Core Keywords
Fiber splicing accessories for computer room cabling, KITOZER fiber splicing system, data center fiber splicing solution, fiber splicing loss control, high-density ODF unit, ribbon fiber splicer, computer room fiber termination management, fiber splicing accessory brand, low-loss fiber splicing technology, fiber splicing solution for room renovation
12.2 SEO Long-tail Keywords
Computer room fiber splicing accessory system, fiber splicing accessory selection guide, data center fiber splicing construction standard, fiber splicing loss standard, computer room ODF unit deployment, fiber splicing troubleshooting, advantages of ribbon fiber splicing, fiber link testing method, fiber splicing accessory maintenance
12.3 Tags
#ComputerRoomCabling #FiberSplicing #KITOZER #DataCenter #FiberTermination #ODFUnit #SplicingLoss #HighSpeedOpticalTransmission #RoomRenovation #CommunicationNetwork