Table of Contents
ToggleI. System Introduction
1.1 System Overview
The lead-acid battery system for server rooms serves as the core energy storage unit to guarantee uninterrupted power supply for data centers, telecommunication rooms and all types of critical IT facilities. As the energy reserve core of UPS (Uninterruptible Power Supply) systems, it instantly delivers stable DC power once utility power fails or malfunctions, ensuring continuous operation of loads and preventing data loss and business downtime. Renowned for outstanding performance and reliability, KITOZER lead-acid batteries are the ideal choice for server room UPS systems and widely deployed across various critical infrastructure sectors.
1.2 System Working Principle
The KITOZER lead-acid battery system operates based on a three-phase cycle: Charging – Energy Storage – Discharging.
- Normal utility power: The UPS rectifier converts AC power into DC power, which supplies power to the inverter and maintains the battery bank via float charging to keep batteries fully charged.
- Abnormal utility power: The battery bank immediately discharges power to loads through the inverter. The switching time is less than 4ms with zero interruption to keep equipment running.
- Utility power recovery: The system automatically switches back to mains mode and resumes float charging for the battery bank to get ready for future power outages.

1.3 Core System Values
| Core Value | Detailed Description |
|---|---|
| Zero-interruption Protection | Millisecond-level switching response prevents unexpected power cuts for critical devices and secures data. |
| Stable Power Supply | Output voltage fluctuation is controlled within ±1%, delivering pure power for sensitive IT equipment. |
| Wide Environmental Adaptability | Designed for a wide temperature range of -10℃ ~ 45℃, adaptable to various server room conditions. |
| Long Service Life | Designed float life reaches 10 to 15 years at 25℃, cutting total lifecycle costs. |
| High Safety & Reliability | Adopts valve-regulated sealed technology with zero risk of electrolyte leakage and built-in multi-protection mechanisms. |
II. System Composition
The KITOZER lead-acid battery system consists of the following core components that work jointly to ensure stable operation.
| Component Name | Function Description |
|---|---|
| Lead-Acid Battery Bank | Core energy storage unit composed of multiple single batteries connected in series to provide required DC voltage and capacity. |
| Battery Management System (BMS) | Real-time monitoring of voltage, current, temperature, internal resistance and other parameters of each cell; enables intelligent charge-discharge management and fault early warning. |
| Battery Connection Assemblies | Including busbars, connecting cables and insulators to ensure reliable connection and safe isolation of the battery bank. |
| Battery Cabinet / Rack | Provides physical support, protection and heat dissipation. Designed with insulation, fire resistance and ventilation to fit server room layouts. |
| Battery Protection Devices | Including fuses, circuit breakers and surge protectors to prevent overcurrent, short circuit, overvoltage and other faults. |
| Ventilation & Heat Dissipation System | Maintains proper operating temperature for batteries to extend service life and improve system stability. |
| Monitoring & Communication Interfaces | Supports RS485, Modbus and other protocols for seamless connection with UPS hosts and server room environment monitoring systems. |

III. System Classification
3.1 Classification by Battery Type
| Category | Technical Features | Application Scenarios |
|---|---|---|
| Valve-Regulated Lead-Acid Battery (VRLA) | Low-liquid design, internal oxygen cycle, maintenance-free sealing, no acid mist emission and high safety. | General server rooms, small & medium data centers, telecommunication base stations. |
| Gel Lead-Acid Battery | Gel electrolyte, good thermal stability, excellent deep cycle performance and strong vibration resistance. | Server rooms in extreme environments, long-term unattended sites. |
| Flooded Lead-Acid Battery | Traditional design requiring regular maintenance with low cost for specific applications. | Large data centers, scenarios with frequent charge and discharge cycles. |
3.2 Classification by Installation Method
| Category | Features | Application Scenarios |
|---|---|---|
| Vertical Installation | Single-cell standalone installation with large floor space occupancy; suitable for spacious rooms. | Large data centers, dedicated battery rooms. |
| Rack-Mounted Installation | Standard 3U/6U rack design, space-saving and easy for centralized management. | Small & medium server rooms, integrated cabinet systems. |
| Containerized Installation | Integrated inside standard containers for outdoor deployment and modular expansion. | Edge data centers, temporary server rooms. |
3.3 Classification by Capacity Level
| Capacity Level | Typical Applications |
|---|---|
| Small Capacity (≤100Ah) | Desktop UPS, small network rooms, edge computing nodes. |
| Medium Capacity (100Ah–500Ah) | Small & medium data centers, enterprise server rooms, telecommunication rooms. |
| Large Capacity (≥500Ah) | Large data centers, cloud computing centers, supercomputer centers. |

IV. System Configuration List (KITOZER)
4.1 Standard Configuration by Power Rating
4.1.1 Supporting System for 10kVA UPS
| No. | Device Name | Model | Brand | Qty | Unit | Remarks |
|---|---|---|---|---|---|---|
| 1 | Valve-Regulated Sealed Lead-Acid Battery | NP12-100 | KITOZER | 8 | Cells | 12V/100Ah, 10-year float life @ 25℃ |
| 2 | Battery Monitoring & Management Module | K-BMS-16 | KITOZER | 1 | Set | Supports 16-cell monitoring, RS485 communication |
| 3 | Battery Connecting Cable | KC-16-500 | KITOZER | 1 | Set | 16mm² copper core, 500mm length |
| 4 | Battery Busbar | KB-1000 | KITOZER | 1 | Set | Matches 100Ah battery bank |
| 5 | Battery Cabinet | KBC-8 | KITOZER | 1 | Set | Holds 8 cells, with ventilation & heat dissipation |
| 6 | Battery Protection Device | KBP-63 | KITOZER | 1 | Set | 63A circuit breaker + surge protection |
| 7 | Temperature Sensor | KT-100 | KITOZER | 2 | Pcs | Monitors battery bank temperature |
| 8 | Communication Module | KCM-485 | KITOZER | 1 | Pc | Modbus protocol, UPS communication interface |
4.1.2 Supporting System for 20kVA UPS
| No. | Device Name | Model | Brand | Qty | Unit | Remarks |
|---|---|---|---|---|---|---|
| 1 | Valve-Regulated Sealed Lead-Acid Battery | NP12-150 | KITOZER | 16 | Cells | 12V/150Ah, 12-year float life @ 25℃ |
| 2 | Battery Monitoring & Management Module | K-BMS-32 | KITOZER | 1 | Set | Supports 32-cell monitoring, LCD display |
| 3 | Battery Connecting Cable | KC-25-600 | KITOZER | 1 | Set | 25mm² copper core, 600mm length |
| 4 | Battery Busbar | KB-1500 | KITOZER | 2 | Sets | Matches 150Ah battery bank |
| 5 | Battery Cabinet | KBC-16 | KITOZER | 2 | Sets | 8 cells per cabinet, intelligent heat dissipation |
| 6 | Battery Protection Device | KBP-100 | KITOZER | 1 | Set | 100A circuit breaker + multi-level surge protection |
| 7 | Temperature Sensor | KT-100 | KITOZER | 4 | Pcs | Distributed temperature monitoring |
| 8 | Communication Module | KCM-485 | KITOZER | 1 | Pc | Modbus protocol, remote monitoring supported |
| 9 | Insulation Monitoring Device | KIM-200 | KITOZER | 1 | Set | Real-time insulation status monitoring |
4.1.3 Supporting System for 50kVA UPS
| No. | Device Name | Model | Brand | Qty | Unit | Remarks |
|---|---|---|---|---|---|---|
| 1 | Valve-Regulated Sealed Lead-Acid Battery | NP2-1000 | KITOZER | 48 | Cells | 2V/1000Ah, 15-year float life @ 25℃ |
| 2 | Battery Monitoring & Management System | K-BMS-64 | KITOZER | 1 | Set | Supports 64-cell monitoring, Web management interface |
| 3 | Battery Connecting Cable | KC-50-800 | KITOZER | 1 | Set | 50mm² copper core, 800mm length |
| 4 | Battery Busbar | KB-2000 | KITOZER | 4 | Sets | Matches 1000Ah battery bank |
| 5 | Battery Rack | KBF-48 | KITOZER | 1 | Set | Holds 48 cells, with ventilation system |
| 6 | Battery Protection Device | KBP-250 | KITOZER | 1 | Set | 250A circuit breaker, intelligent protection |
| 7 | Temperature Sensor | KT-200 | KITOZER | 8 | Pcs | High-precision temperature monitoring |
| 8 | Communication Gateway | KCG-100 | KITOZER | 1 | Set | Multi-protocol conversion supported |
| 9 | Insulation Monitoring Device | KIM-500 | KITOZER | 1 | Set | Multi-channel insulation monitoring |
| 10 | Fire Linkage Module | KFM-100 | KITOZER | 1 | Pc | Linked with server room fire protection system |

V. System Schematic Diagram
5.1 Block Diagram of KITOZER Lead-Acid Battery System
Utility Input → UPS Rectifier ─┬→ Inverter → Load Devices
                 │
                 └→ KITOZER Lead-Acid Battery Bank (Float Charging)
                       ↑
                       │
               Battery Management System (BMS)
                       ↑
                       │
               Environment Monitoring System (Remote Monitoring)
5.2 Detailed Working Process
- Normal Mode: Utility power is converted into DC power by the rectifier. One branch supplies the inverter for stable AC output, while the other float-charges the KITOZER battery bank. BMS monitors battery status in real time.
- Power Failure Mode: BMS detects mains abnormality and triggers immediate battery discharge. Power is delivered to loads via the inverter with seamless switching.
- Fault Protection Mode: BMS automatically cuts off the battery circuit when low voltage, over temperature or short circuit occurs, protecting the battery bank and UPS equipment.
- Remote Monitoring Mode: BMS uploads battery data to the environment monitoring system via communication interfaces for remote monitoring, alarm and data analysis.

VI. Product Technical Parameters
6.1 Parameters of KITOZER Valve-Regulated Sealed Lead-Acid Batteries
| Parameter Category | Parameter Name | NP12 Series (12V) | NP2 Series (2V) |
|---|---|---|---|
| Basic Parameters | Rated Voltage | 12V | 2V |
| Rated Capacity | 7Ah/17Ah/24Ah/38Ah/65Ah/100Ah/150Ah | 200Ah/500Ah/1000Ah/2000Ah/3000Ah | |
| Battery Type | Valve-Regulated Sealed Lead-Acid (VRLA) | Valve-Regulated Sealed Lead-Acid (VRLA) | |
| Plate Type | Lead-Calcium Multi-Alloy Plate | Lead-Calcium Multi-Alloy Plate | |
| Electrolyte Type | Low-liquid / Gel | Low-liquid / Gel | |
| Electrical Performance | Float Charging Voltage | 13.5–13.8V (@25℃) | 2.23–2.27V (@25℃) |
| Equalizing Charging Voltage | 14.4–14.7V (@25℃) | 2.35–2.40V (@25℃) | |
| Max. Charging Current | 0.25C10 | 0.25C10 | |
| Max. Discharging Current | 3C10 (5 seconds) | 3C10 (5 seconds) | |
| Internal Resistance | ≤8mΩ (100Ah) | ≤0.5mΩ (1000Ah) | |
| Environmental Adaptability | Operating Temperature Range | -10℃ ~ 45℃ | -10℃ ~ 45℃ |
| Optimal Operating Temperature | 25℃ | 25℃ | |
| Relative Humidity | ≤90% (@20℃) | ≤90% (@20℃) | |
| Altitude | ≤1000m | ≤1000m | |
| Lifespan Parameters | Designed Float Life | 10–12 years (@25℃) | 12–15 years (@25℃) |
| Cycle Life | ≥1000 cycles (80% DOD) | ≥1200 cycles (80% DOD) | |
| Safety Parameters | Safety Valve Opening Pressure | 10–35kPa | 10–35kPa |
| Explosion-Proof Rating | IP21 | IP21 | |
| Flame Retardant Rating | UL94 V-0 | UL94 V-0 | |
| Physical Parameters | Dimensions (mm) | Varies by capacity | Varies by capacity |
| Weight (kg) | Varies by capacity | Varies by capacity | |
| Terminal Type | Bolt / Tab | Bolt |
6.2 Parameters of KITOZER Battery Management System (BMS)
| Parameter Name | Technical Specifications |
|---|---|
| Monitoring Channels | 16/32/64 channels, expandable |
| Monitored Items | Voltage, current, temperature, internal resistance, SOC, SOH |
| Measurement Accuracy | Voltage: ±0.5%FS; Temperature: ±1℃; Current: ±1%FS |
| Communication Interfaces | RS485 (Modbus RTU), Ethernet (Modbus TCP/IP) |
| Operating Voltage | DC12V / 24V |
| Operating Temperature | -20℃ ~ 60℃ |
| Protection Rating | IP30 |
| Alarm Modes | Audible & visual alarm, dry contact output, remote alarm |
| Data Storage | Supports historical data storage and export for analysis |

VII. Application Scope
7.1 Core Application Fields
| Application Field | Specific Scenarios | Application Value |
|---|---|---|
| Data Center | Large cloud data centers, financial data centers, enterprise data centers | Ensures continuous operation of server clusters and storage devices, prevents data loss. |
| Telecommunication Rooms | Telecom operator rooms, 5G base stations, core network rooms | Guarantees uninterrupted operation of communication equipment and stable network. |
| Industrial Control | Automated production lines, DCS systems, PLC control centers | Avoids production downtime and maintains continuous industrial processes. |
| Medical Equipment | Operating room devices, ICU monitoring systems, medical imaging equipment | Keeps life-support devices running to save lives. |
| Financial Institutions | Bank data centers, ATM systems, payment clearing systems | Prevents financial transaction interruptions and secures capital. |
| Government Agencies | Government cloud platforms, emergency command centers, confidential rooms | Ensures continuous government services and national security. |
| Energy Industry | Substations, power plant DCS systems, new energy monitoring centers | Maintains stable power system operation and prevents grid accidents. |
7.2 Applicable UPS Types
KITOZER lead-acid battery systems are compatible with all mainstream UPS topologies:
- Online UPS: Adopts double-conversion technology to deliver the highest level of power protection for scenarios requiring strict power quality.
- Line-Interactive UPS: Features voltage regulation to reduce battery cycling frequency, suitable for general server rooms.
- Standby UPS: Simple structure and low cost, applied to scenarios with low requirements on power continuity.

VIII. Product Advantages
8.1 Core Competitive Strengths
| Advantage Category | Detailed Description |
|---|---|
| High Reliability | Lead-calcium multi-alloy plates are adopted; cycle life reaches 1000–1200 cycles and float life is 10–15 years @ 25℃. |
| Excellent Performance | High-power discharge capability meets instantaneous high power demand of data centers for smooth equipment switching. |
| Safety & Environmental Protection | Valve-regulated sealed design eliminates electrolyte leakage and acid mist emission, fully complying with environmental standards. |
| Low Maintenance | Maintenance-free design with no need for distilled water refilling, cutting O&M costs and fitting long-term unattended sites. |
| Strong Environmental Adaptability | Wide operating temperature range (-10℃ ~ 45℃); retains over 80% capacity even at low temperatures. |
| Intelligent Management | Matched BMS monitors battery status in real time, gives early fault warnings and extends service life. |
| High Compatibility | Compatible with mainstream UPS brands and supports parallel expansion to meet various power demands. |
| Cost-Effective | Low total lifecycle cost with short return on investment cycle. |
8.2 Comparison with Other Energy Storage Technologies
| Comparison Item | KITOZER Lead-Acid Battery | Lithium Battery |
|---|---|---|
| Reliability | Extremely high, mature technology with low failure rate | High, requiring sophisticated management systems |
| Safety | No thermal runaway risk, high safety | Potential thermal runaway risk, strict management required |
| Environmental Adaptability | Wide temperature range (-10℃ ~ 45℃), good low-temperature performance | Poor low-temperature performance with severe capacity attenuation |
| Maintenance Cost | Maintenance-free, low cost | Requires professional maintenance, high cost |
| Cycle Life | 1000–1200 cycles (80% DOD) | 2000–3000 cycles (80% DOD) |
| Float Life | 10–15 years (@25℃) | 5–8 years |
| Initial Investment | Low | High |
| Recycling Value | High, mature recycling system | Low, high recycling cost |

IX. Bid Control Parameters
9.1 Core Bid Parameters for Batteries
| Control Item | Technical Requirements |
|---|---|
| Brand Requirement | Must be KITOZER brand; original manufacturer authorization certificate is required. |
| Product Type | Valve-Regulated Sealed Lead-Acid Battery (VRLA); open-type batteries are prohibited. |
| Capacity Tolerance | Capacity deviation ≤ ±3% based on matching UPS power. |
| Lifespan Requirement | Designed float life ≥ 10 years @ 25℃; cycle life ≥ 1000 cycles (80% DOD). |
| Safety Standard | Complies with GB/T 19638.2; certified by UL and CE. |
| Temperature Adaptability | Operating range: -10℃ ~ 45℃; capacity ≥ 80% rated capacity at 0℃. |
| Discharge Performance | 10-hour rate discharge capacity ≥ rated capacity; 30-minute rate discharge capacity ≥ 85% rated capacity. |
| Internal Resistance | Internal resistance of new batteries shall not exceed specified value; resistance deviation within the whole bank ≤ 5%. |
| Sealing Performance | Pass air tightness test with no electrolyte leakage. |
| Environmental Requirement | Complies with RoHS directive, no excessive heavy metals. |
9.2 Bid Parameters for Battery Management System
| Control Item | Technical Requirements |
|---|---|
| Monitoring Functions | Must support voltage, current, temperature, internal resistance, SOC and SOH monitoring. |
| Communication | Supports RS485 (Modbus RTU) and Ethernet (Modbus TCP/IP). |
| Alarm Functions | Equipped with audible & visual alarm, dry contact output and remote alarm. |
| Data Storage | Supports historical data storage and export; storage period ≥ 1 year. |
| Expandability | Supports battery bank expansion and adapts to different capacity systems. |
| Compatibility | Compatible with mainstream UPS brands and connectable to environment monitoring systems. |
9.3 Bid Parameters for System Integration
| Control Item | Technical Requirements |
|---|---|
| Connection | Copper connecting components; cables comply with national standards; connection resistance within specified range. |
| Protection | Equipped with overload, short circuit, overvoltage and overtemperature protection devices. |
| Installation | Battery cabinets/racks feature ventilation, heat dissipation, insulation and fireproof design. |
| Testing | Complete factory test reports including capacity, internal resistance and safety tests shall be provided. |
| Warranty | Minimum 3-year warranty; free replacement for faulty batteries within warranty period. |
| Service | Professional installation guidance and regular maintenance services; 24-hour technical support. |
X. Product Solutions
10.1 High-Reliability Solution for Data Centers
10.1.1 Solution Overview
To meet the ultra-high requirements on power reliability and stability of large data centers, this integrated solution combines KITOZER lead-acid batteries, online UPS and intelligent BMS to ensure 7×24 non-stop operation.
10.1.2 Solution Architecture
Dual Utility Input → ATS Switch → Redundant Online UPS → Power Distribution System → Server Cluster
                 ↑
                 │
                 └→ Dual Parallel KITOZER Battery Banks → BMS → Environment Monitoring Center
10.1.3 Solution Features
- Redundant architecture: Dual mains, dual UPS and dual battery banks eliminate single points of failure.
- Intelligent management: BMS monitors every single cell and gives early warnings of potential faults.
- Fast response: Battery instant discharge with switching time less than 2ms for imperceptible switching.
- Remote monitoring: Web-based remote management, real-time status view and automatic analysis reports.
- Hot swap: Batteries can be replaced without system shutdown during maintenance.
- Fire linkage: Automatically cuts off battery circuits once fire is detected for safety.
10.2 Cost-Effective Solution for Small & Medium Server Rooms
10.2.1 Solution Overview
Tailored for small & medium enterprise rooms and branch offices, this cost-efficient solution adopts KITOZER lead-acid batteries plus line-interactive UPS to guarantee basic power reliability while cutting investment costs.
10.2.2 Solution Architecture
Utility Input → Line-Interactive UPS → Load Devices
           ↑
           │
           └→ KITOZER Battery Bank → Basic BMS Monitoring Module
10.2.3 Solution Features
- Cost optimization: Line-interactive UPS with voltage regulation reduces battery cycling and extends service life.
- Compact layout: Standard rack-mounted batteries save room space.
- Basic monitoring: Simplified BMS monitors key parameters to ensure basic safety.
- Rapid deployment: Standard configuration for easy installation and shorter project cycle.
- Easy maintenance: Maintenance-free design lowers O&M costs for small and medium enterprises.
10.3 Integrated Solution for Edge Computing Nodes
10.3.1 Solution Overview
For outdoor or space-limited scenarios such as 5G base stations and edge computing nodes, this solution applies KITOZER gel lead-acid batteries and integrated UPS with high reliability and environmental adaptability.
10.3.2 Solution Features
- Extreme environment adaptability: Gel batteries work stably from -20℃ to 60℃.
- Integrated design: UPS and batteries are integrated into standard cabinets for space saving and easy deployment.
- Remote management: 4G/5G remote monitoring fits unattended sites.
- Low power consumption: Optimized charge-discharge strategy reduces energy use and extends battery life.
- High protection rating: IP54 protection for harsh outdoor environments.
XI. Application Cases
11.1 Case 1: Financial Data Center Project in Guangzhou
11.1.1 Project Background
This financial data center carries core banking systems and payment clearing services, requiring 99.9999% power availability. Any power cut will lead to huge economic losses and reputation risks.
11.1.2 Solution
Adopted KITOZER NP2-1000 2V/1000Ah VRLA batteries, two sets of 48-cell battery banks (total capacity 96000Ah) matched with K-BMS-64. Combined with two 200kVA online UPS to form a redundant power system.
11.1.3 Implementation Results
- Realized zero-interruption power supply and ensured 7×24 continuous financial services.
- BMS gave early warnings for 3 potential faults and prevented battery bank failure.
- Batteries operate stably with capacity retention above 95%; actual service life has reached 8 years, exceeding expectation.
- Obtained safety certification from the central bank and became a benchmark case in the financial industry.
11.2 Case 2: 5G Core Telecommunication Room Project in Shenzhen
11.2.1 Project Background
This 5G core room undertakes regional 5G network coverage. Continuous power supply for base station controllers and transmission equipment is required to keep network unblocked.
11.2.2 Solution
Adopted KITOZER NP12-150 12V/150Ah VRLA batteries, two sets of 16-cell banks equipped with K-BMS-32, forming a power system with two 100kVA online UPS.
11.2.3 Implementation Results
- Successfully coped with 3 utility power outages and kept communication equipment running nonstop.
- Remote monitoring via BMS; staff check battery status anytime via mobile APP.
- Batteries work stably under room temperature up to 35℃ with capacity retention over 90%.
- O&M costs reduced by 60%; battery replacement cycle extended to 8 years, highly recognized by the operator.
11.3 Case 3: Hospital ICU Project in Beijing
11.3.1 Project Background
The ICU is equipped with a large number of life-support devices including ventilators, ECG monitors and infusion pumps. Any power interruption will threaten patients’ lives, requiring extremely high power reliability.
11.3.2 Solution
Adopted KITOZER NP12-65 12V/65Ah VRLA batteries, two sets of 8-cell banks matched with K-BMS-16 and two 20kVA online UPS to build a redundant power system for ICU devices.
11.3.3 Implementation Results
- Maintained normal operation during 5 grid fluctuations and 2 long-duration power cuts, protecting patients’ lives.
- Precise battery monitoring by BMS keeps the battery bank in optimal condition all the time.
- Maintenance-free design eases hospital O&M pressure; passed health authority safety certification.
- Became a typical application case of UPS battery systems in the medical industry and promoted in multiple hospitals.
XII. SEO Keywords & Tags
12.1 Search Keywords
Server room lead-acid battery, KITOZER battery, UPS lead-acid battery, server room uninterruptible power supply, data center battery system, valve-regulated sealed lead-acid battery, battery management system, BMS system, server room battery solution, telecommunication room battery, lead-acid battery technical parameters, server room battery configuration list, lead-acid battery application cases, KITOZER brand battery, server room battery bid parameters
12.2 SEO Optimization Guidelines
- Core keyword layout: Distribute core keywords such as server room lead-acid battery and KITOZER battery reasonably across the full text to improve search engine ranking.
- Long-tail keywords: Adopt long-tail keywords including data center lead-acid battery solution and small & medium server room battery configuration to cover more search scenarios.
- Content structure: Use clear heading levels and lists for better crawling and understanding by search engines.
- Technical parameter enrichment: List detailed product parameters to enhance professionalism and search relevance.
- Authentic cases: Provide real application cases to improve content credibility and user stickiness.
12.3 Tags
#ServerRoomLeadAcidBattery #KITOZER #UPSBattery #DataCenter #TelecommunicationRoom #ValveRegulatedLeadAcidBattery #BMSSystem #UninterruptiblePowerSupply #BatterySolution #ServerRoomConstruction #LeadAcidBatteryTechnology #BatteryConfigurationList #BidParameters #ApplicationCases