KITOZER
KITOZER

Tower UPS Solution for Server Rooms (Brand: KITOZER)

I. System Introduction

1.1 System Overview

Tower UPS is an independently floor-standing uninterruptible power supply system, designed to deliver high-quality and non-stop power protection for server rooms, data centers and critical equipment. Adopting online double-conversion topology, KITOZER Tower UPS realizes seamless switching between mains power and battery power (0ms) via core modules including rectifier, inverter, energy storage and static bypass. It supplies pure, stable and continuous power to IT devices, precision instruments and control systems, and effectively isolates power grid anomalies such as voltage fluctuation, harmonic interference, transient voltage and power outage.

1.2 Working Principle

The core operating process of KITOZER Tower UPS is as follows:

  1. Normal Mains Mode: Utility AC power is converted into DC power by the rectifier. Part of the DC power maintains float charging of the battery bank, while the rest is inverted into pure sine-wave AC power to supply loads.
  2. Battery Discharge Mode: Once mains power fails, the battery bank immediately feeds power to loads through the inverter. The switching time is less than 2ms, ensuring imperceptible power change for connected devices.
  3. Bypass Mode: The system automatically switches to static bypass when the UPS malfunctions or overloads, so loads are powered directly by mains to sustain normal operation.
  4. Maintenance Bypass: Manual switch to maintenance bypass is supported to facilitate UPS servicing without cutting power to loads.

1.3 System Features

  • Fully digital control: Equipped with DSP digital signal processor for precise control and intelligent management.
  • Wide input voltage range: Adaptable to harsh power grid conditions, reducing frequent battery discharge and extending battery service life.
  • High efficiency & energy saving: Efficiency reaches up to 95% under mains mode, and over 98% under ECO mode.
  • Intelligent monitoring: Built-in LCD display, remote monitoring, fault early warning and automatic protection functions.
  • Flexible expansion: Battery bank expansion is available to meet different backup runtime requirements.
modular ups solution for server rooms 1 (7)

II. System Composition

The KITOZER Tower UPS system consists of the following core components to build a comprehensive power guarantee system:

Component NameFunction DescriptionCore Technical Features
UPS Main UnitCore of the system, realizes power conversion and uninterrupted power supplyOnline double-conversion topology, full DSP digital control, IGBT power devices
Battery BankEnergy storage unit, provides power when mains failsVRLA lead-acid batteries or lithium batteries; hot-swap expansion supported
Battery CabinetMounting and protection device for battery bankDesigned with ventilation, heat dissipation, fire prevention and short-circuit protection
Input & Output Power DistributionPower distribution and protectionCircuit breakers, surge protectors and contactors; provides overcurrent, short circuit and surge protection
Monitoring SystemReal-time monitoring and remote managementSupports RS232/RS485, SNMP and Modbus protocols; Web/SNMP monitoring available
Environment MonitoringMonitors server room temperature, humidity, smoke and access controlLinked with UPS system to issue early warnings for environmental anomalies
Cables & Connection AccessoriesPower transmission and signal connectionFlame-retardant cables and aviation connectors for safe and reliable connection
modular ups solution for server rooms 1 (1)

III. System Classification

3.1 Classification by Power Rating

Power LevelApplication ScenariosTypical Models
Low Power (1–10kVA)Small server rooms, server cabinets, network devicesKITOZER KT1K–KT10K Series
Medium Power (10–40kVA)Medium-sized data centers, enterprise server rooms, precision laboratoriesKITOZER KT10K–KT40K Series
High Power (40–200kVA)Large data centers, cloud computing centers, industrial control systemsKITOZER KT40K–KT200K Series

3.2 Classification by Circuit Topology

  1. High-Frequency Tower UPS
    • No output transformer; compact size, light weight and high efficiency (above 95%).
    • Ideal for space-limited server rooms with stable loads.
    • The full KITOZER series adopts high-frequency design for energy conservation and environmental friendliness.
  2. Power-Frequency Tower UPS
    • Built-in output isolation transformer with strong anti-impact capability and high reliability.
    • Suitable for industrial environments and scenarios with high proportion of inductive and non-linear loads.
    • Power-frequency models are optional for KITOZER KT series.

3.3 Classification by Phase

Phase TypeInput & OutputApplication Scenarios
Single-Phase Input / Single-Phase Output220VACLow-power UPS (1–10kVA), office server rooms, small network devices
Three-Phase Input / Single-Phase Output380VAC input, 220VAC outputMedium-power UPS (10–20kVA), server clusters, precision instruments
Three-Phase Input / Three-Phase Output380VACHigh-power UPS (above 20kVA), data centers, industrial control systems
high frequency ups solution for server rooms (2)

IV. System Configuration List (KITOZER)

4.1 Standard Configuration (10kVA Example)

No.Device NameModelSpecificationsQtyRemarks
1Tower UPS Main UnitKITOZER KT10K10kVA/8kW, online double-conversion, 380V input, 220V output1 UnitWith LCD display and RS485 communication port
2Valve-Regulated Lead-Acid BatteryKITOZER KTB1210012V/100Ah, maintenance-free16 CellsApprox. 30-minute backup runtime
3Battery CabinetKITOZER KTC1619-inch standard cabinet, holds 16pcs 12V batteries1 SetEquipped with battery cables and ventilation system
4Input Distribution CabinetKITOZER KTP-100A100A input circuit breaker, surge protection module1 UnitMatches 10kVA UPS
5Output Distribution CabinetKITOZER KTP-80A80A output circuit breaker, 4 output circuits, overload protection1 UnitMatches 10kVA UPS
6Monitoring ModuleKITOZER KTM-01Supports RS232/RS485 and SNMP protocols1 SetWith monitoring software for remote management
7Connecting CablesKITOZER KTC-350+125Copper core, flame-retardant, 350mm²+125mm²1 SetFor input and output connection
8Installation AccessoriesKITOZER KTA-01Brackets, screws and user manual1 SetComplete installation fittings

4.2 Optional Configuration

No.Device NameModelFunctionApplication Scenarios
1Lithium Battery BankKITOZER KTL1210012V/100Ah lithium battery, long cycle lifeScenarios requiring long backup runtime and frequent discharge
2Environment Monitoring UnitKITOZER KTE-01Monitors temperature, humidity, smoke and access statusServer room environment monitoring and linked alarm
3Remote Management CardKITOZER KTR-01Supports Web/SNMP remote monitoringUnattended server rooms and centralized management
4Parallel ModuleKITOZER KTP-02Enables parallel operation of multiple UPS unitsHigh-reliability requirements, N+1 redundant design
5Battery Inspection TesterKITOZER KTB-01Real-time status monitoring for each single batteryLong battery strings requiring refined management

V. System Schematic Diagram

Mains Input (380V/220V) ────┐
│
Input Circuit Breaker
│
Surge Protection Module
│
Input Filter
│
┌───────────────────────────┴───────────────────────────┐
│ KITOZER Tower UPS Main Unit │
│ ┌─────────┐ ┌─────────┐ ┌─────────────┐ │
│ │ Rectifier│─────▶│ Inverter│─────▶│ Output Filter│ │
│ └─────────┘ └─────────┘ └─────────────┘ │
│ │ ▲ │
│ │ │ │
│ ▼ │ │
│ ┌─────────┐ ┌─────────┐ ┌─────────────┐ │
│ │ Charger │─────▶│Battery │─────▶│Static Bypass │ │
│ └─────────┘ └─────────┘ └─────────────┘ │
│ ▲ ▲ │
│ │ │ │
│ Battery Cabinet Maintenance Bypass Switch │
└───────────────────────────┬───────────────────────────┘
│
Output Circuit Breaker
│
Load Distribution Cabinet
│
┌──────────┬──────────┬──────────┬──────────┐
│Server Racks│Network Devices│Storage Devices│Precision Instruments│
└──────────┴──────────┴──────────┴──────────┘

5.1 Operating Modes

  1. Normal Mode: Mains → Rectifier → Inverter → Load; the battery is float-charged simultaneously.
  2. Battery Discharge Mode: Battery → Inverter → Load; automatic switchover within 2ms when mains fails.
  3. Bypass Mode: Mains → Static Bypass → Load; activated automatically upon UPS fault or overload.
  4. Maintenance Mode: Mains → Maintenance Bypass → Load; manual switchover for UPS maintenance.
  5. Parallel Operation Mode: Multiple UPS units connected via parallel modules for load sharing and redundant backup.
ups input and output power distribution cabinet solution for server rooms (6)

VI. Product Technical Parameters (KITOZER KT Series)

6.1 Basic Parameters

ParameterKT1K–KT10K (Single-Phase)KT10K–KT40K (Three-Phase)KT40K–KT200K (Three-Phase)
UPS TypeTower, Online Double-ConversionTower, Online Double-ConversionTower, Online Double-Conversion
Rated Capacity1–10kVA10–40kVA40–200kVA
Rated Power0.8–8kW8–32kW32–160kW
Input Voltage220VAC±25%380VAC±20%380VAC±15%
Input Frequency50Hz±10%50Hz±5%50Hz±3%
Input Power Factor≥0.98≥0.98≥0.99
Input Current THD≤5%≤3%≤2%
Output Voltage220VAC±1%380VAC±1%380VAC±0.5%
Output Frequency50Hz±0.1%50Hz±0.05%50Hz±0.01%
Output WaveformSine wave, THD<2% (Linear Load)Sine wave, THD<2% (Linear Load)Sine wave, THD<1% (Linear Load)
Switching Time0ms (Double-Conversion)0ms (Double-Conversion)0ms (Double-Conversion)
Efficiency (Mains Mode)≥93%≥94%≥95%
Efficiency (ECO Mode)≥97%≥98%≥98.5%
Overload Capability125% load for 10 mins, 150% load for 1 min125% load for 10 mins, 150% load for 1 min125% load for 10 mins, 150% load for 1 min
Battery TypeVRLA Lead-Acid / Lithium BatteryVRLA Lead-Acid / Lithium BatteryVRLA Lead-Acid / Lithium Battery
Backup RuntimeStandard 5–15 mins, expandableStandard 10–30 mins, expandableStandard 15–60 mins, expandable
Communication PortsRS232/RS485, SNMP optionalRS232/RS485, SNMPRS232/RS485, SNMP, Modbus
DisplayLCD, Chinese InterfaceLCD, Chinese InterfaceColor LCD Touch Screen, Chinese Interface
Dimensions (W×D×H)450×600×800mm600×800×1000mm800×1000×1200mm
Weight50–150kg150–300kg300–800kg
Operating Environment0–40℃, 20%–90% RH (Non-condensing)0–40℃, 20%–90% RH (Non-condensing)0–40℃, 20%–90% RH (Non-condensing)
Noise<55dB @ 1m<60dB @ 1m<65dB @ 1m

6.2 Protection Parameters

Protection TypeProtection StandardProtection Action
Overvoltage ProtectionOutput >115% rated voltageSwitch to bypass and trigger alarm
Undervoltage ProtectionOutput <85% rated voltageSwitch to bypass and trigger alarm
Overload Protection105%–125% load: 10 mins125%–150% load: 1 min>150% load: 0.5 secAlarm first, then switch to bypass
Short Circuit ProtectionOutput short circuitImmediately cut off output and alarm
Overtemperature ProtectionInternal temp. >85℃Derate operation; shut down if temperature keeps rising
Battery Overcharge ProtectionBattery voltage >13.8V per cellStop charging and alarm
Battery Overdischarge ProtectionBattery voltage <10.5V per cellCut off output and alarm
Surge ProtectionCompliant with IEC 61000-4-5Discharge surge current to protect devices

VII. Application Scope

KITOZER Tower UPS provides reliable power protection for critical equipment in the following scenarios:

7.1 Data Centers & Server Rooms

  • Enterprise data centers: Servers, storage devices, network switches and other core IT equipment
  • Cloud computing centers: Large-scale server clusters requiring high reliability and availability
  • Edge computing nodes: Distributed small server rooms with independent power demand
  • Financial institution server rooms: Core business systems of banks, securities and insurance industries requiring zero-interruption power supply

7.2 Government & Public Sectors

  • Government cloud platforms: E-government systems to ensure continuous public services
  • Medical institutions: Operating room devices, ICU monitoring systems and medical imaging equipment
  • Education & Research: University laboratories, research equipment and supercomputers
  • Energy industry: Power dispatching centers, substation automation systems and new energy monitoring platforms

7.3 Industry & Manufacturing

  • Automated production lines: PLC systems, robots and precision processing equipment
  • Petrochemical industry: DCS and Safety Instrumented Systems (SIS)
  • Semiconductor manufacturing: Cleanroom control and wafer processing equipment
  • Automotive manufacturing: Body welding, painting and assembly line control systems

7.4 Commerce & Service Industry

  • Hotel chains: Hotel management, guest room control and security monitoring systems
  • Shopping malls: POS systems, central air conditioning and security systems
  • Radio & Television: Broadcasting, transmitting and editing room equipment
  • Transportation: Dispatching systems and security inspection devices at airports, railway stations and metro stations

VIII. Product Advantages

8.1 Performance Advantages

  1. Zero-interruption power supply: Online double-conversion design with 0ms switching time for transparent power changeover.
  2. Pure power output: Voltage stability ±1%, frequency stability ±0.1%, THD<2%, ideal for precision devices.
  3. Wide input range: Tolerates severe grid fluctuations, reduces battery discharge frequency and extends service life.
  4. High efficiency & energy saving: Up to 95% efficiency in mains mode and over 98% in ECO mode to cut operational costs.

8.2 Reliability Advantages

  1. Full digital control: DSP chip ensures precise control and self-diagnosis to improve system reliability.
  2. Redundant key components: Redundant design for power modules and fans eliminates single points of failure.
  3. Intelligent battery management: Supports charge-discharge management, temperature compensation and overcharge/overdischarge protection.
  4. Comprehensive protection: Full-range safeguards against overvoltage, undervoltage, overload, short circuit and overtemperature.

8.3 Management Advantages

  1. Intelligent monitoring: LCD displays real-time operating data; remote monitoring and fault warning available.
  2. Multiple communication ports: RS232/RS485, SNMP, Modbus for connection with DCIM systems.
  3. Remote operation: Web access and mobile APP monitoring support unattended O&M.
  4. Event recording & analysis: Historical data storage for fault tracing and performance evaluation.

8.4 Deployment Advantages

  1. Floor-standing installation: No cabinet required, flexible for various server room layouts.
  2. Easy installation: Modular structure shortens deployment cycle.
  3. Convenient maintenance: Front access design for easy component replacement.
  4. Flexible expansion: Battery bank expandable to meet different backup runtime demands.

IX. Bid Specification Parameters

9.1 Core Technical Parameters (★ Mandatory Items)

Bid ItemTechnical RequirementRemarks
★ UPS TypeTower type, online double-conversion topology; high-frequency model (no output transformer) or power-frequency model (with output transformer)Product manual required for verification
★ Rated CapacityNo less than [XX]kVA/[XX]kWFill according to project demands
★ Input Voltage Range380VAC±20% (Three-Phase) / 220VAC±25% (Single-Phase)Test report required
★ Output Voltage Stability±1% (Steady load), ±3% (Dynamic load)Test report required
★ Switching Time0ms (Double-conversion mode); bypass switching time <2msTechnical white paper required
★ Efficiency≥94% in mains mode, ≥97% in ECO modeThird-party test report required
★ Output THD≤2% for linear loads, ≤5% for non-linear loadsTest report required
★ Overload Capability125% load for 10 minutes, 150% load for 1 minuteTechnical datasheet required
★ Battery ManagementEquipped with battery temperature compensation, overcharge/overdischarge protection and cell inspection functionFunction description required
★ Communication PortsAt least RS485 and SNMP ports; Web monitoring supportedPort list required
★ Protection FunctionsMultiple protections including overvoltage, undervoltage, overload, short circuit, overtemperature and surge protectionProtection list required
★ CertificationsCE, UL, ISO9001, ISO14001Copies of certificates required

9.2 Commercial Bid Requirements

Bid ItemRequirementRemarks
Brand QualificationBidder brand has more than [XX] years of UPS manufacturing experience; business license and project references requiredRelevant documents required
After-sales Service[XX] years warranty; on-site response within [XX] hours and arrival within [XX] hoursAfter-sales commitment letter required
Local ServiceLocal service center and spare parts warehouse available at project locationAddress and contact information required
TrainingFree technical training covering installation, commissioning and maintenanceTraining plan required

X. Product Solutions

10.1 Solution for Small & Medium Enterprise Server Rooms (10kVA)

Solution Overview

KITOZER KT10K Tower UPS (1+0 configuration) is recommended for small and medium enterprise server rooms with 30-minute backup runtime, meeting the demands of core business systems.

Configuration

  • UPS Main Unit: KITOZER KT10K (10kVA/8kW), online double-conversion
  • Battery Bank: 16pcs KITOZER KTB12100 (12V/100Ah), 30-minute backup
  • Battery Cabinet: KITOZER KTC16, 19-inch standard cabinet
  • Power Distribution: KITOZER KTP series distribution cabinets with surge protection
  • Monitoring System: KITOZER KTM-01 monitoring module for remote management

Features

  • Cost-effective, matching SME budget with reliable power guarantee.
  • Fast deployment: Installation completed within 1–2 days.
  • Intelligent remote monitoring reduces O&M workload.
  • Expandable batteries or parallel UPS for business growth.

10.2 Solution for Large Data Centers (100kVA)

Solution Overview

KITOZER KT100K Tower UPS with 3+1 N+1 redundant configuration and 60-minute backup runtime is adopted for large data centers, complying with Tier III standards.

Configuration

  • UPS Main Unit: 4pcs KITOZER KT100K (100kVA/80kW), 3+1 redundancy
  • Battery Bank: 4 groups × 40pcs KITOZER KTB12200 (12V/200Ah)
  • Battery Cabinet: 4pcs KITOZER KTC40 standard cabinets
  • Power Distribution: KITOZER KTP series cabinets supporting parallel operation
  • Monitoring System: KITOZER KTM-02 advanced monitoring module, connected to DCIM
  • Environment Monitoring: KITOZER KTE-01 for temperature, humidity and smoke detection

Features

  • N+1 redundancy eliminates single points of failure, meets Tier III requirements.
  • Parallel operation realizes automatic load sharing and high system efficiency.
  • Full monitoring for predictive maintenance.
  • High efficiency lowers PUE and complies with green data center standards.

10.3 Solution for Industrial Control Systems (50kVA)

Solution Overview

KITOZER KT50K power-frequency Tower UPS is selected for industrial control systems. With built-in isolation transformer, it delivers strong anti-interference capability for harsh industrial environments.

Configuration

  • UPS Main Unit: KITOZER KT50K power-frequency model (50kVA/40kW) with output isolation transformer
  • Battery Bank: 32pcs KITOZER KTB12150 (12V/150Ah), 45-minute backup
  • Battery Cabinet: 2pcs KITOZER KTC32, IP54 protection class
  • Power Distribution: Industrial-grade KITOZER KTP cabinets with EMI/RFI filters
  • Monitoring System: KITOZER KTM-01, Modbus protocol for SCADA connection

Features

  • Output isolation transformer effectively isolates grid interference.
  • Wide temperature adaptability (-10℃~50℃) and high protection grade.
  • Compatible with inductive loads such as motors and inverters.
  • Seamless connection with SCADA for industrial automatic management.

XI. Application Cases

11.1 Case 1: Data Center Renovation Project of XX Bank

Project Background

The existing UPS system of XX Bank’s data center was aging and needed upgrading to ensure continuous operation of core trading and credit systems.

Solution

  • 3pcs KITOZER KT80K Tower UPS with 2+1 redundant configuration
  • KITOZER KTB12200 battery banks for 60-minute backup runtime
  • Connected to DCIM system for remote monitoring and management
  • Deployed environment monitoring system for real-time temperature, humidity and smoke detection

Project Effects

  • Stable operation for 2 years with zero faults, ensuring uninterrupted core business.
  • System efficiency increased by 15%, saving about 800,000 RMB on electricity annually.
  • Remote monitoring cuts on-site inspection workload by 70%.
  • Complies with Level 3 Information Security Protection standards for banking systems.

11.2 Case 2: Automotive Production Line Automation Project of XX Automobile Manufacturer

Project Background

A new body welding production line required reliable power for PLC systems, robots and testing equipment to avoid shutdown caused by voltage fluctuations.

Solution

  • 2pcs KITOZER KT50K power-frequency Tower UPS with 1+1 redundant configuration
  • KITOZER KTB12150 battery banks for 45-minute backup runtime
  • Installed KITOZER KTE-01 environment monitoring unit
  • Connected to factory SCADA system for linkage with production line controls

Project Effects

  • Production line operates stably without power-related shutdowns.
  • Effectively isolates grid harmonics and transients, extending equipment service life.
  • Equipment maintenance cost reduced by 30% and production efficiency improved.
  • Fully meets high-reliability requirements of automotive automated production lines.

11.3 Case 3: Power Guarantee Project for ICU Wards of XX Hospital

Project Background

The newly built ICU ward required zero-interruption power for ventilators, patient monitors and infusion pumps to protect patients’ lives.

Solution

  • 2pcs KITOZER KT20K Tower UPS with 1+1 redundant configuration
  • KITOZER KTB12100 battery banks for 30-minute backup runtime
  • KITOZER KTM-01 monitoring module with remote alarm function
  • Linked with hospital emergency power system for automatic generator switchover

Project Effects

  • 24-hour uninterrupted power supply for ICU critical devices.
  • Zero switching interruption prevents medical accidents caused by power cuts.
  • Remote monitoring enables timely fault handling and faster response.
  • Complies with medical industry power supply specifications.

XII. Keywords, SEO & Tags

12.1 Search Keywords

Server room tower UPS solution, KITOZER tower UPS, online double-conversion UPS, data center UPS system, uninterruptible power supply solution, tower UPS configuration list, UPS system schematic, UPS bid parameters, green data center UPS, industrial UPS solution

12.2 SEO Optimization

  • Title: Tower UPS Solution for Server Rooms (KITOZER) – Complete Technical Solution
  • Description: KITOZER tower UPS solution including system introduction, composition, classification, configuration, schematic, parameters and application cases, providing reliable power protection for server rooms.
  • Core Keywords: Server room UPS, tower UPS, KITOZER, uninterruptible power supply, data center power supply

12.3 Tags

#ServerRoomUPS #TowerUPS #KITOZER #UninterruptiblePowerSupply #DataCenter #PowerProtection #UPSSolution #BidParameters #GreenDataCenter #IndustrialUPS

Shopping Cart