The KITOZER computer room shielding door system is core electromagnetic protection equipment specially designed for data centers, classified computer rooms, precision equipment rooms and other scenarios. Adopting the Faraday cage shielding principle, integrated with automatic control and mobile intelligent management technologies, it builds a full-band electromagnetic isolation barrier.
The system can effectively block electromagnetic signal leakage and external interference within the 10kHz–18GHz frequency band, prevent mobile phone signal penetration, electromagnetic eavesdropping on data, and equipment signal crosstalk. It ensures stable operation of servers, switches and other equipment inside computer rooms, while meeting classified information security and Electromagnetic Compatibility (EMC) requirements. As a key movable component of the computer room shielding system, the KITOZER shielding door addresses the pain points of traditional shielding doors including poor sealing, high high-frequency leakage and insufficient intelligence. It integrates automatic opening/closing, mobile remote control, access control linkage, status monitoring and other functions, compatible with low, medium and high protection grades, and is widely applied in computer room scenarios of finance, government, military, communications and other industries.

Computer Room Shielding Door
2. System Composition
The KITOZER computer room shielding door system consists of seven major parts: door body structure, shielding sealing assembly, automatic drive system, mobile intelligent control system, access recognition module, grounding system and emergency safety device. All modules work together to realize integrated shielding, automation and intelligent management:
- Door Body Structure: Integral box-type welding with cold-rolled steel plate / galvanized steel plate, including door frame, door leaf and reinforcing ribs to guarantee structural strength and electrical continuity.
- Shielding Sealing Assembly: Core components include beryllium bronze finger springs, conductive rubber strips and knife-edge sealing structure, realizing full-perimeter conductive sealing of door gaps to avoid electromagnetic leakage.
- Automatic Drive System: Composed of motor, transmission mechanism, controller and track (adaptable to sliding / swing types), driving automatic door opening and closing with buffer and anti-pinch functions.
- Mobile Intelligent Control System: Integrated with WiFi / Bluetooth modules, remote control APP and status feedback unit, supporting mobile remote door operation, permission management and fault alarm push notifications.
- Access Recognition Module: Optional fingerprint, password, card swiping and face recognition, linked with automatic door to enable automatic door opening after identity verification.
- Grounding System: Special grounding copper busbar and flexible copper braided wire connect the door body to the equipotential equalizing network of the computer room, with grounding resistance ≤1Ω to rapidly discharge static electricity and induced current.
- Emergency Safety Device: Emergency unlocking handle, power-off manual opening mechanism and fire linkage interface to ensure safe personnel evacuation in emergencies.

CAD Drawing of Computer Room Shielding Door
3. System Classification
3.1 Classification by Shielding Effectiveness (Core Protection Grade)
- Basic Low-Grade (Class C): 10kHz–1GHz ≥55dB, 1GHz–18GHz ≥45dB. Applicable to small enterprise general computer rooms and non-classified office weak current rooms.
- Enhanced Medium-Grade (Class B): 10kHz–1GHz ≥65dB, 1GHz–18GHz ≥55dB. Applicable to commercial data centers, non-classified government computer rooms and communication base station machine rooms.
- High-Performance High-Grade (Class A): 10kHz–18GHz ≥75dB, high-frequency band (1GHz–18GHz) ≥70dB. Applicable to classified computer rooms, core financial data centers, military command machine rooms and precision laboratories.
3.2 Classification by Opening Mode
- Swing Type: Single / double leaf, hinged, suitable for door openings ≤1.5m in width, featuring simple structure and convenient maintenance.
- Sliding Type: Single / double sliding, track-driven, suitable for door openings 1.5–3m in width, space-saving and stable in operation.
- Interlocked Double Door Type: Two shielding doors linked and interlocked to prevent electromagnetic leakage when a single door is open, for high-confidentiality scenarios.
3.3 Classification by Control Mode

Production Workshop of Lai’an Intelligence
- Automatic Induction Type: Infrared / microwave induction, automatic door opening on approach, suitable for high-frequency passage scenarios.
- Mobile Intelligent Type: Mobile APP remote control, Bluetooth short-range door operation and hierarchical permission management, suitable for remote operation and maintenance scenarios.
- Access Control Linked Type: Automatic opening/closing after fingerprint / card swiping / face recognition, linked with security systems, suitable for high-safety management scenarios.
4. System Schematic Logic
Mobile APP → Wireless communication module (WiFi/Bluetooth) → Automatic door controller → Drive motor → Door opening & closing
↓
Access recognition module (Fingerprint/Card Swipe) → Signal verification → Controller → Linked opening & closing
↓
Shielding sealing assembly (Spring strips/Conductive rubber strips) → Conductive sealing of door gaps → Electromagnetic shielding
↓
Grounding system (Copper busbar/Braided wire) → Equipotential connection → Static electricity discharge
↓
Emergency device → Power-off / Fire signal → Manual unlocking / Automatic door opening
Note: The core of the schematic diagram reflects the signal and control logic integrating mobile control, automatic drive, shielding sealing, grounding protection and emergency linkage. All modules adopt electrical isolation and closed-loop signals to guarantee stable shielding performance and intelligent control simultaneously.
5. System Configuration List (Low / Medium / High Grades, Brand: KITOZER)
5.1 Basic Low-Grade Configuration List

On-site Installation of Shielding Door
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Swing Shielding Door Body | KT-PB600 | 1.2mm cold-rolled steel door frame, 1.0mm steel door leaf, size 900×2100mm, integral welding | 1 | Set | KITOZER | Basic protection, dual manual & automatic modes |
| 2 | Shielding Sealing Assembly | KT-MF55 | 2 rows of beryllium bronze spring strips, 5×5mm conductive rubber strips, compression 0.5mm | 1 | Set | KITOZER | For Class C shielding, door gap ≤0.5mm |
| 3 | Automatic Drive Motor | KT-DJ150 | 220VAC, 150W, 15r/min, torque 20N·m, noise ≤55dB | 1 | Unit | KITOZER | Special for swing doors, anti-pinch function |
| 4 | Automatic Door Controller | KT-CON01 | Supports infrared induction / button control, delay closing 0–10s adjustable, overload protection | 1 | Unit | KITOZER | Basic automatic control |
| 5 | Mobile Control Module | KT-WF01 | WiFi connection, APP remote door operation, status feedback, 10 user permissions | 1 | Set | KITOZER | APP: KITOZER Shielding Door Control |
| 6 | Access Card Reader | KT-RF01 | RFID card reading, 13.56MHz frequency, reading distance 5–10cm | 1 | Unit | KITOZER | Basic identity verification |
| 7 | Grounding Copper Busbar | KT-TP20 | 20×4mm pure copper busbar, length 1.5m, grounding resistance ≤4Ω | 1 | Piece | KITOZER | Connect door body to computer room grounding grid |
| 8 | Emergency Unlocking Handle | KT-YJ01 | Mechanical manual unlocking, usable under power failure, fire linkage interface | 1 | Piece | KITOZER | For emergency evacuation |
5.2 Enhanced Medium-Grade Configuration List
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Sliding Shielding Door Body | KT-PY700 | 1.5mm galvanized steel door frame, 1.2mm steel door leaf, size 1200×2100mm, box welding with reinforcing ribs | 1 | Set | KITOZER | Class B protection, sliding opening/closing |
| 2 | Shielding Sealing Assembly | KT-MF65 | 3 rows of beryllium bronze spring strips, 8×8mm conductive rubber strips, copper-plated knife edge, compression 0.8mm | 1 | Set | KITOZER | Full-perimeter sealing for Class B shielding |
| 3 | Automatic Drive Motor | KT-DJ250 | 220VAC, 250W, 20r/min, torque 35N·m, buffer start-stop, noise ≤50dB | 1 | Unit | KITOZER | Special for sliding doors, silent operation |
| 4 | Automatic Door Controller | KT-CON02 | Supports induction / access / mobile control, delay closing 0–30s adjustable, fault self-diagnosis | 1 | Unit | KITOZER | Intelligent linkage control |
| 5 | Mobile Control Module | KT-WF02 | Dual WiFi + Bluetooth connection, APP remote control + Bluetooth short-range operation, 50 user permissions, abnormal alarm push | 1 | Set | KITOZER | Multi-device management supported |
| 6 | Fingerprint Access Control All-in-One Machine | KT-FP02 | Fingerprint recognition rate ≥99% + password + card swiping, living body detection, anti-pry alarm | 1 | Unit | KITOZER | Multi-dimensional identity verification |
| 7 | Complete Grounding System Kit | KT-TP30+KT-BZ | 30×5mm pure copper busbar (2m) + 4 multi-strand copper braided wires, grounding resistance ≤2Ω | 1 | Set | KITOZER | Equipotential connection, anti-corrosion |
| 8 | Emergency Safety Device Set | KT-YJ02 | Dual electric & manual unlocking, automatic door opening on fire linkage, emergency lighting (90min endurance) | 1 | Set | KITOZER | High-safety emergency guarantee |
| 9 | Status Monitoring Sensor | KT-CG01 | Door magnetic status monitoring, opening/closing records, abnormal opening alarm | 1 | Piece | KITOZER | Real-time operation status monitoring |
5.3 High-Performance High-Grade Configuration List
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Interlocked Double Shielding Door Body | KT-HS750 | 2.0mm copper-plated steel door frame, 1.5mm steel door leaf, interlocked double doors, single leaf size 1000×2100mm, full welding + sealed cabin design | 2 | Set | KITOZER | Class A protection, interlock anti-leakage |
| 2 | Shielding Sealing Assembly | KT-MF75 | 4 rows of beryllium bronze spring strips, double-layer conductive rubber strips, stainless steel knife edge, compression 1.0mm, no attenuation after 30,000 opening/closing cycles | 2 | Set | KITOZER | Full-band sealing for Class A shielding |
| 3 | Automatic Drive Motor | KT-DJ400 | 220VAC, 400W, 25r/min, torque 50N·m, variable frequency speed regulation, silent ≤45dB, overheat protection | 2 | Unit | KITOZER | Synchronous drive for double doors |
| 4 | Intelligent Linked Controller | KT-CON03 | PLC control, supports mobile / access / fire / security linkage, delay closing 0–60s adjustable, 1-year data storage | 1 | Unit | KITOZER | System hub for intelligent coordination |
| 5 | Mobile Intelligent Control Module | KT-WF03 | Triple 5G+WiFi+Bluetooth connection, APP remote control + video monitoring + hierarchical permissions (Administrator / Operator), SMS + APP dual abnormal alarm push | 1 | Set | KITOZER | Remote operation & maintenance + safety monitoring |
| 6 | Face Recognition Access All-in-One Machine | KT-RL03 | Face recognition accuracy ≥99.5% + fingerprint + password + card swiping + remote authorization, living body detection, anti-pry / anti-coercion alarm | 2 | Unit | KITOZER | Dual-door identity verification, high security |
| 7 | Special Grounding System | KT-TP40+KT-BZ-G | 40×6mm pure copper busbar (3m) + 8 high-flexibility copper braided wires + grounding monitor, grounding resistance ≤1Ω | 1 | Set | KITOZER | Class A classified information grounding standard |
| 8 | Emergency Safety Kit | KT-YJ03 | Automatic unlocking on power failure + mechanical emergency handle + forced door opening on fire linkage + emergency lighting (190min endurance) + escape indicators | 1 | Set | KITOZER | Military-grade emergency guarantee |
| 9 | Full-Status Monitoring System | KT-CG02 | Door magnetic + temperature + humidity + leakage monitoring, real-time data upload, abnormal early warning, remote diagnosis | 1 | Set | KITOZER | Full life cycle monitoring |
| 10 | Shielding Effectiveness Detection Interface | KT-JC01 | Reserved spectrum analyzer detection interface, encrypted detection points at door gaps / lock cores / hinges | 1 | Set | KITOZER | For acceptance and regular inspection |
6. Full Product Technical Parameters
6.1 Shielding Door Body Technical Parameters

Structure Drawing of Shielding Door
- Basic Low-Grade (KT-PB600): Cold-rolled steel material, door frame thickness 1.2mm, door leaf thickness 1.0mm, size 900×2100mm, shielding effectiveness 10kHz–1GHz≥55dB, 1GHz–18GHz≥45dB, swing opening mode, integral box-type welding structure.
- Enhanced Medium-Grade (KT-PY700): Galvanized steel material, door frame thickness 1.5mm, door leaf thickness 1.2mm, size 1200×2100mm, shielding effectiveness 10kHz–1GHz≥65dB, 1GHz–18GHz≥55dB, sliding opening mode, box welding with reinforcing ribs.
- High-Performance High-Grade (KT-HS750): Copper-plated steel material, door frame thickness 2.0mm, door leaf thickness 1.5mm, single leaf size 1000×2100mm, shielding effectiveness 10kHz–18GHz≥75dB, interlocked double door opening mode, full welding + sealed cabin structure.
6.2 Shielding Sealing Assembly Technical Parameters

Installation Effect of Shielding Door
- Basic Low-Grade (KT-MF55): 2 rows of beryllium bronze spring strips, 5×5mm conductive rubber strips, compression 0.5mm, door gap ≤0.5mm, service life ≥10,000 cycles.
- Enhanced Medium-Grade (KT-MF65): 3 rows of beryllium bronze spring strips, 8×8mm conductive rubber strips, copper-plated knife edge, compression 0.8mm, door gap ≤0.3mm, service life ≥20,000 cycles.
- High-Performance High-Grade (KT-MF75): 4 rows of beryllium bronze spring strips, double-layer conductive rubber strips, stainless steel knife edge, compression 1.0mm, door gap ≤0.2mm, service life ≥30,000 cycles, full-band leakage-free sealing.
6.3 Automatic Drive Motor Technical Parameters
- Basic Low-Grade (KT-DJ150): 220VAC, power 150W, speed 15r/min, torque 20N·m, noise ≤55dB, protection grade IP44.
- Enhanced Medium-Grade (KT-DJ250): 220VAC, power 250W, speed 20r/min, torque 35N·m, buffer start-stop, noise ≤50dB, protection grade IP54.
- High-Performance High-Grade (KT-DJ400): 220VAC, power 400W, speed 25r/min, torque 50N·m, variable frequency speed regulation, noise ≤45dB, protection grade IP65, overheat / overload protection.
6.4 Mobile Intelligent Control Module Technical Parameters
- Basic Low-Grade (KT-WF01): WiFi connection, unlimited control distance (network), 10 user permissions, functions: remote door operation + status feedback.
- Enhanced Medium-Grade (KT-WF02): WiFi + Bluetooth dual connection, Bluetooth control distance ≤10m, 50 user permissions, functions: remote control + Bluetooth operation + abnormal alarm push.
- High-Performance High-Grade (KT-WF03): 5G+WiFi+Bluetooth triple connection, Bluetooth control distance ≤15m, hierarchical user permissions (Administrator / Operator), functions: remote control + video monitoring + SMS/APP dual alarm + remote authorization.
6.5 Access Recognition Equipment Technical Parameters
- RFID Card Reader (KT-RF01): Frequency 13.56MHz, reading distance 5–10cm, response time ≤0.5s.
- Fingerprint Access All-in-One Machine (KT-FP02): Fingerprint recognition rate ≥99%, response time ≤0.8s, storage capacity for 1,000 fingerprints, anti-pry alarm.
- Face Recognition Access All-in-One Machine (KT-RL03): Recognition accuracy ≥99.5%, response time ≤0.3s, storage capacity for 5,000 face templates, living body detection, anti-coercion alarm.
6.6 Grounding System Technical Parameters

Lai’an Intelligent Command Platform
- Basic Low-Grade: 20×4mm pure copper busbar, length 1.5m, grounding resistance ≤4Ω.
- Enhanced Medium-Grade: 30×5mm pure copper busbar (2m) + 4 copper braided wires, grounding resistance ≤2Ω.
- High-Performance High-Grade: 40×6mm pure copper busbar (3m) + 8 high-flexibility copper braided wires + grounding monitor, grounding resistance ≤1Ω.
7. Product Application Scope
7.1 Basic Low-Grade Application Scope
- Small enterprise general office computer rooms, non-classified department weak current rooms.
- Community supporting building machine rooms, small monitoring centers, general laboratories.
- Scenarios with limited budget and basic electromagnetic protection demands, to prevent mobile phone signal penetration and minor interference.
7.2 Enhanced Medium-Grade Application Scope
- Commercial data centers, cloud computing machine rooms, enterprise core business computer rooms.
- Non-classified government machine rooms, educational institution machine rooms, communication base station machine rooms.
- Bank branch computer rooms, industrial automatic control rooms, precision instrument laboratories.
- Scenarios requiring suppression of equipment signal crosstalk, stable data transmission and mobile intelligent management.
7.3 High-Performance High-Grade Application Scope

Shielding Door Engineering Case 1
- Class A/B classified computer rooms, military command centers, core classified government premises.
- Head office financial data centers, securities trading machine rooms, insurance core business machine rooms.
- 5G/6G core communication machine rooms, satellite ground stations, Electromagnetic Compatibility (EMC) laboratories.
- Scenarios requiring full-band electromagnetic isolation, prevention of electromagnetic eavesdropping on data, high-safety management and remote operation & maintenance.
8. Product Advantages
8.1 Core Functional Features
- Outstanding Shielding Performance: Adopt combined knife-edge + multi-row beryllium bronze spring strip sealing structure with continuous full-perimeter conductivity. Shielding effectiveness ≥55dB (low grade), ≥65dB (medium grade), ≥75dB (high grade), effectively blocking mobile phone signals, electromagnetic interference and data leakage.
- Automatic & Intelligent Control: Integrated automatic drive + mobile APP remote control + access linkage, supporting multiple opening modes including induction / card swiping / fingerprint / face recognition. Mobile anytime & anywhere management, suitable for unattended scenarios.
- High-Reliability Structural Design: Integrally welded door body with thickened steel plates and reinforcing ribs, anti-deformation and impact-resistant; sealing components have a service life of 10,000–30,000 cycles with no obvious attenuation of shielding performance after long-term use.
- Comprehensive Safety Protection: Equipped with anti-pinch, buffer start-stop, emergency unlocking and fire linkage functions; manual opening under power failure to guarantee personnel safety. Standardized grounding system rapidly discharges static electricity to avoid secondary interference.
- Low Noise & Energy Saving: Variable frequency / buffer motor design, operating noise ≤45–55dB, low power consumption; standby sleep mode for energy conservation.
8.2 Customization Services

Shielding Door Engineering Case 2
- Size Customization: Custom single / double leaf, swing / sliding / interlocked door bodies according to door opening dimensions, maximum width up to 3m.
- Function Customization: Custom mobile control interface, access permission hierarchy, linkage logic (fire / security / lighting) and shielding effectiveness grade.
- Material Customization: Optional cold-rolled steel plate, galvanized steel plate, copper-plated steel plate and stainless steel plate, adapting to special demands of anti-corrosion, rust-proof and non-magnetic environments.
- Appearance Customization: Custom surface spraying color, logo engraving and shielding glass observation windows to match the overall decoration style of computer rooms.
8.3 Production & Supply Chain Advantages
- OEM/ODM Processing Service: Support OEM/ODM processing, provide complete technical solutions and production support with customer brand labeling.
- Confidentiality Agreement Guarantee: Sign strict confidentiality agreements to protect customer technical parameters, customized schemes and project information against leakage.
- Spot Supply: Regular low/medium-grade models in stock for delivery within 72 hours; customized high-grade models delivered in 15–20 days to meet project schedules.
- Full-Series Technical Support: Full-process technical support from design, production, installation to commissioning; free provision of installation drawings, technical training and remote guidance.
9. Tender Control Parameters (★ Marked)
9.1 Shielding Door Body Tender Control Parameters
★ Shielding Effectiveness: Low grade 10kHz–1GHz≥55dB, 1GHz–18GHz≥45dB; Medium grade 10kHz–1GHz≥65dB, 1GHz–18GHz≥55dB; High grade 10kHz–18GHz≥75dB.
★ Door Body Structure: Integral box-type welding, splicing riveting prohibited; electrical continuity between door frame and leaf required.
★ Material Thickness: Low grade door frame ≥1.2mm, door leaf ≥1.0mm; Medium grade door frame ≥1.5mm, door leaf ≥1.2mm; High grade door frame ≥2.0mm, door leaf ≥1.5mm.
★ Opening Mode: Swing / sliding / interlocked double door supported; interlocked doors must feature dual-door linkage interlock function.
9.2 Shielding Sealing Assembly Tender Control Parameters
★ Sealing Structure: Combined knife-edge + beryllium bronze finger spring strips; ≥2 rows (low grade), ≥3 rows (medium grade), ≥4 rows (high grade).
★ Compression: Sealing component compression ≥0.5mm (low grade), ≥0.8mm (medium grade), ≥1.0mm (high grade); door gap ≤0.5mm (low grade), ≤0.3mm (medium grade), ≤0.2mm (high grade).
★ Service Life: ≥10,000 cycles (low grade), ≥20,000 cycles (medium grade), ≥30,000 cycles (high grade), no obvious attenuation of shielding performance.
9.3 Automatic Drive System Tender Control Parameters
★ Motor Power: Low grade ≥150W, medium grade ≥250W, high grade ≥400W; protection grade ≥IP44 (low grade), ≥IP54 (medium grade), ≥IP65 (high grade).
★ Operating Noise: ≤55dB (low grade), ≤50dB (medium grade), ≤45dB (high grade); buffer start-stop and anti-pinch functions mandatory.
★ Control Functions: Adjustable delay closing (0–10s low grade, 0–30s medium grade, 0–60s high grade), overload / overheat protection and fault self-diagnosis.
9.4 Mobile Intelligent Control System Tender Control Parameters
★ Connection Mode: Low grade WiFi only; medium grade WiFi + Bluetooth; high grade 5G+WiFi+Bluetooth; mobile APP remote control supported.
★ Permission Management: ≥10 users (low grade), ≥50 users (medium grade), hierarchical permissions (Administrator / Operator) (high grade), abnormal alarm push supported.
★ Response Time: Remote control response ≤1s, Bluetooth control response ≤0.5s, real-time status feedback synchronization.
9.5 Grounding System Tender Control Parameters
★ Grounding Resistance: Low grade ≤4Ω, medium grade ≤2Ω, high grade ≤1Ω; special grounding copper busbar connects door body to computer room equipotential equalizing network.
★ Grounding Material: Pure copper busbar + multi-strand copper braided wire, cross-section ≥20×4mm (low grade), ≥30×5mm (medium grade), ≥40×6mm (high grade).
10. Complete Product Solutions
10.1 Small Enterprise Computer Room Shielding Solution (Low Grade)
- Pain Points: Limited budget, basic electromagnetic protection, prevention of mobile phone signal interference, simple access management.
- Solution: Adopt KITOZER low-grade swing shielding door (KT-PB600), matched with WiFi mobile control module, RFID card reader, basic sealing assembly and grounding system.
- Effect: Shielding effectiveness ≥55dB, blocking mobile phone signal penetration and external electromagnetic interference affecting equipment operation; mobile APP remote door operation and card access management realize basic safety control; convenient installation and low cost for rapid deployment of small machine rooms.
10.2 Commercial Data Center Shielding Solution (Medium Grade)
- Pain Points: Dense equipment, severe signal crosstalk, unstable data transmission, demand for intelligent management and remote operation & maintenance.
- Solution: Adopt KITOZER medium-grade sliding shielding door (KT-PY700), matched with WiFi+Bluetooth mobile control module, fingerprint access all-in-one machine, enhanced sealing assembly, grounding system and status monitoring sensor.
- Effect: Shielding effectiveness ≥65dB, effectively suppressing equipment signal crosstalk and high-frequency harmonic interference to guarantee stable data transmission; mobile remote + Bluetooth short-range control, fingerprint identity verification, real-time status monitoring and timely abnormal alarm push; silent operation with buffer start-stop, suitable for high-frequency passage scenarios to improve operation & maintenance efficiency.
10.3 Classified / Core Financial Computer Room Shielding Solution (High Grade)
- Pain Points: Prevent leakage of classified data, full-band electromagnetic isolation, high-safety management, remote operation & maintenance and emergency guarantee.
- Solution: Adopt KITOZER high-grade interlocked double shielding door (KT-HS750), matched with 5G+WiFi+Bluetooth mobile control module, face recognition access all-in-one machine, high-performance sealing assembly, special grounding system, full-status monitoring system and emergency safety kit.
- Effect: Shielding effectiveness ≥75dB, full-band blocking of electromagnetic signals to eliminate risks of electromagnetic eavesdropping on classified data; interlocked double door design eliminates leakage blind spots; face recognition + remote authorization and hierarchical permission management, full-status monitoring and abnormal early warning; fire linkage and emergency lighting guarantee safe personnel evacuation, applicable to high-confidentiality & high-safety scenarios including military, finance and government.
11. Product Application Cases
11.1 Small Internet Company Computer Room Project (Low Grade)
- Project Overview: 50㎡ computer room with 20 servers, non-classified office machine room, limited budget, demand to prevent mobile phone signal interference.
- Product Configuration: 1 set of KITOZER low-grade swing shielding door (KT-PB600), WiFi mobile control module, RFID card reader, basic sealing and grounding system.
- Project Effect: Detected shielding effectiveness ≥58dB, mobile phone signals cannot penetrate the computer room, stable equipment operation without signal interference; mobile APP remote door operation enables all-time administrator management without on-site duty; 3-day installation cycle with controllable cost, meeting basic protection demands.
11.2 Commercial Bank Branch Data Center Project (Medium Grade)
- Project Overview: 200㎡ computer room with 100 servers, core business machine room, demand to guarantee stable data transmission and intelligent operation & maintenance.
- Product Configuration: 1 set of KITOZER medium-grade sliding shielding door (KT-PY700), WiFi+Bluetooth mobile control module, fingerprint access all-in-one machine, enhanced sealing assembly, grounding system and status monitoring sensor.
- Project Effect: Detected shielding effectiveness ≥68dB, effectively suppressing equipment signal crosstalk and reducing data transmission error rate to zero; mobile remote control + fingerprint access allow operation & maintenance staff to operate doors remotely and check status, with timely push of abnormal alarms; silent operation without jams under high-frequency passage, improving operation & maintenance efficiency and ensuring continuous stable banking business.
11.3 Military Unit Classified Command Machine Room Project (High Grade)
- Project Overview: 150㎡ Class A classified machine room, demand for full-band electromagnetic isolation, high-safety management and emergency guarantee.
- Product Configuration: 2 sets of KITOZER high-grade interlocked double shielding door (KT-HS750), 5G+WiFi+Bluetooth mobile control module, face recognition access all-in-one machine, high-performance sealing assembly, special grounding system, full-status monitoring system and emergency safety kit.
- Project Effect: Detected shielding effectiveness ≥78dB, full-band leakage-free with zero risk of electromagnetic leakage of classified data; interlocked double doors eliminate leakage blind spots, face recognition + remote authorization realize high-safety management; real-time early warning via full-status monitoring and automatic door opening on fire linkage ensure personnel safety; passed military-grade acceptance and stable operation for 3 years without faults, winning high customer recognition.
12. Product Faults & Maintenance
12.1 Common Faults & Troubleshooting Methods
- Fault 1: Door cannot open/close automatically
- Troubleshooting: Check power supply, motor overload, controller failure, mobile/access signal status.
- Solution: Restore power, restart motor/controller, inspect signal connections, replace faulty components.
- Fault 2: Degraded shielding effectiveness, mobile phone signals penetrate the door
- Troubleshooting: Check deformed / fallen spring strips, aged conductive rubber strips, excessive door gap, poor grounding connection.
- Solution: Replace deformed spring strips / aged rubber strips, adjust door gap, re-connect grounding system.
- Fault 3: Mobile remote control fails
- Troubleshooting: Check network connection, APP version, offline module, expired user permissions.
- Solution: Restore network, update APP, restart control module, re-authorize user access.
- Fault 4: Access recognition failure
- Troubleshooting: Dirty identification equipment, expired fingerprint/face templates, faulty card reader.
- Solution: Clean equipment, re-enter identity information, replace card reader.
- Fault 5: Excessive operating noise
- Troubleshooting: Loose motor, worn transmission components, foreign objects on tracks.
- Solution: Fasten motor, replace worn components, clean foreign objects on tracks.
12.2 Maintenance Specifications
- Daily Maintenance: Inspect door body for deformation, intact sealing components, normal mobile control & access functions, abnormal operating noise.
- Weekly Maintenance: Clean spring strips and conductive rubber strips to remove dust and oil; check door gap clearance and fasten connecting bolts; test effective emergency unlocking function.
- Monthly Maintenance: Inspect motor and transmission components, add lubricating oil; test grounding resistance compliance; calibrate parameters of mobile control module and access equipment.
- Quarterly Maintenance: Detect shielding effectiveness with spectrum analyzer to ensure compliance; replace aged sealing components; fully test fire linkage and emergency lighting functions.
- Annual Maintenance: Disassemble and inspect door welding joints for cracks and reinforcing ribs for deformation; replace severely worn transmission components; full-system debugging and performance calibration, issue maintenance report.
13. Factory Strength & After-Sales Service
13.1 Factory Strength
- Production Scale: 10,000㎡ modern production base, 5 dedicated shielding door production lines, annual output of 10,000 sets to meet mass order demands.
- Technical Team: 20 core R&D engineers with over 10 years of shielding door research experience, mastering core technologies of electromagnetic shielding, automatic control and intelligent management, holding multiple patents.
- Production Equipment: Imported numerical cutting machines, laser welding machines, precision bending machines, shielding effectiveness testers and other advanced equipment for high production precision and stable product quality.
- Quality System: Certified by ISO9001 Quality Management System, ISO14001 Environmental Management System and Military Product Quality System, strictly complying with GB/T 30071-2013 and GJB5792A-2021 standards.
- Supply Chain Advantages: Core components (motors, spring strips, control modules) adopt imported / top domestic brands, stable supply chain to guarantee product quality and delivery cycle.
13.2 After-Sales Service
- Warranty Commitment: Free 3-year warranty for full product series; free repair and component replacement for non-artificial faults within warranty period; lifetime maintenance with only component cost charged after warranty expiry.
- Installation Service: Professional on-site installation, commissioning and training team; free provision of installation drawings and technical disclosure to guarantee installation quality.
- Technical Support: 7×24-hour technical hotline for remote fault diagnosis and troubleshooting guidance; free technical training covering daily operation, maintenance and simple fault handling.
- Rapid Response: 1-hour response upon fault report, remote resolution within 4 hours; on-site service within 24 hours nationwide for on-site handling demands.
- Customization Service: Free software upgrade and parameter optimization within warranty period; free customized functional schemes and technical support per customer demands.
14. Conclusion
With outstanding shielding performance, intelligent automatic control, high-reliability structural design and comprehensive safety protection, the KITOZER computer room shielding door system accurately matches low, medium and high protection grade computer room demands, providing full-scenario shielding solutions from basic electromagnetic protection to classified data security. Integrated with mobile intelligent management technology, it realizes remote operation & maintenance and efficient management, solving the pain points of insufficient intelligence and inconvenient operation & maintenance of traditional shielding doors. Strict quality control, professional technical teams and complete after-sales service guarantee long-term stable product operation, providing solid support for computer room equipment safety, data confidentiality and electromagnetic compatibility. In the future, KITOZER will continue technological innovation, continuously optimize product performance and functions, deepen the field of computer room electromagnetic protection, supply high-quality shielding door products and solutions for more industry customers, and support the safe and stable development of digital infrastructure.
15. SEO Keywords & Tag System
15.1 Core Keywords
- Core Primary Keywords: Computer Room Shielding Door, Electromagnetic Shielding Door, Automatic Shielding Door
- High-Conversion Long-Tail Keywords: Mobile Controlled Computer Room Shielding Door, Classified Computer Room Shielding Door, Data Center Shielding Door, Swing / Sliding Shielding Door, KITOZER Shielding Door
- Industry Traffic Keywords: Computer Room Electromagnetic Protection, Electromagnetic Shielding Solution, Computer Room Shielding Engineering, Shielding Door Manufacturer, Intelligent Shielding Door
- Brand Exclusive Keywords: KITOZER Computer Room Shielding Door, KITOZER Electromagnetic Shielding Door, KITOZER Automatic Shielding Door
- Dropdown / Related Search Keywords: Computer Room Shielding Door Price, Computer Room Shielding Door Specification, Computer Room Shielding Door Installation, Shielding Door Shielding Effectiveness, Shielding Door Brand
15.2 SEO Optimization Tag System
- Core Page Optimization Tag: Computer Room Shielding Door_Electromagnetic Shielding Door_Automatic Shielding Door_KITOZER Shielding Door
- Title Tag: KITOZER Computer Room Shielding Door | Automatic Electromagnetic Shielding Door | Mobile Controlled Classified Computer Room Shielding Door Solution
- Meta Keywords Tag: Computer Room shielding door, electromagnetic shielding door, automatic shielding door, mobile controlled shielding door, classified computer room shielding door, data center shielding door, KITOZER shielding door
- Meta Description Tag: KITOZER provides professional computer room shielding doors, electromagnetic shielding doors and automatic shielding doors with mobile remote control. Optional low/medium/high protection grades for classified computer rooms, data centers and enterprise machine rooms, shielding effectiveness 55–75dB, direct supply from manufacturer, 3-year warranty.
- H1 Tag: KITOZER Computer Room Shielding Door Solution (Automatic + Mobile Control)
- H2 Tags: System Overview, System Composition, System Classification, System Configuration List, Technical Parameters, Application Scope, Product Advantages, Tender Control Parameters, Solutions, Application Cases, Faults & Maintenance, Factory Strength & After-Sales Service
- Internal Link Anchor Text Tags
- Core Anchor Text: Computer Room Shielding Door, Electromagnetic Shielding Door, Automatic Shielding Door
- Long-Tail Anchor Text: Mobile Controlled Computer Room Shielding Door, Classified Computer Room Shielding Door, Data Center Shielding Door, KITOZER Shielding Door
- Related Anchor Text: Computer Room Electromagnetic Protection, Shielding Door Manufacturer, Intelligent Shielding Door, Computer Room Shielding Engineering