KITOZER
KITOZER

KITOZER Electromagnetic Shielding Filter Solution

Table of Contents

1. System Overview

KITOZER’s shielding connector, shielding sealing strip and ventilation waveguide window solution forms an integrated protection system covering full-scenario Electromagnetic Interference (EMI) shielding and Electromagnetic Compatibility (EMC). It integrates nine core components: shielding connectors, shielding sealing strips, ventilation waveguide windows, power filters, signal filters, logic grounding filters, network filters, telephone filters and waveguides.

Centered on the design philosophy of blocking leakage via gap sealing, balancing ventilation and shielding, isolating interfaces through filtering, and purifying protection via grounding, the system blocks electromagnetic wave leakage and external interference across a wide frequency band while guaranteeing equipment heat dissipation & ventilation, power/signal transmission and mechanical sealing. Its shielding efficiency covers 30MHz–18GHz, with graded shielding performance ranging from 30dB to 120dB @1GHz.

Widely applied in high-reliability scenarios including military shelters, classified computer rooms, data centers, precision medical equipment, rail transit and industrial control, it serves as the core guarantee for electromagnetic information security and stable equipment operation.

image

Power Filter Module

2. System Composition

The system consists of nine core functional components plus auxiliary accessories, forming a closed-loop full-link protection workflow: sealing shielding → ventilation shielding → interface shielding → power filtering → signal filtering → grounding protection.

  • Shielding Sealing Strips: Conductive rubber strips, metal wire mesh wrapped strips, beryllium copper spring strips. Used for conductive sealing and gap leakage blocking at cabinet doors, cabin seams and panel joints.
  • Shielding Connectors: RF/signal/network/telephone shielding connectors, adapters and flange joints. Realize electromagnetic sealing, signal isolation and leakage blocking at interfaces.
  • Ventilation Waveguide Windows (Including Waveguides): Aluminum/steel honeycomb waveguide cores, frames and conductive gaskets. Utilize waveguide cut-off characteristics to cut off electromagnetic waves while enabling ventilation and heat dissipation; waveguides support high-frequency signal transmission and electromagnetic isolation.
  • Power Filters: Single-phase/three-phase/DC/broadband power filters. Eliminate common-mode, differential-mode interference, high-frequency clutter and pulse noise on power lines.
  • Signal Filters: RF/analog/digital signal filters. Suppress high-frequency clutter, harmonics and signal leakage on signal cables.
  • Network Filters: Dedicated RJ45 Ethernet filters. Filter crosstalk, high-frequency interference and information leakage of Ethernet signals.
  • Telephone Filters: Audio/telephone line dedicated filters. Suppress low-frequency clutter, surge and electromagnetic interference on telephone lines.
  • Logic Grounding Filters: Low-impedance grounding assemblies and grounding filter modules. Eliminate ground potential interference to ensure pure grounding and equipment safety.
  • Auxiliary Accessories: Conductive gaskets, conductive silicone grease, shielding cables, grounding copper bars, mounting fasteners and three-proof coatings, used to strengthen sealing, electrical conductivity and protection performance.
image

Multi-type Filter Modules

3. System Classification

Classified from four dimensions: protection grade, performance tier, functional module and application scenario, covering low/medium/high tier demands to meet stringent requirements of diverse scenarios.

3.1 Classification by Performance Tier (Core Grading)

  • Basic Tier (Low Grade): Shielding efficiency 30–60dB @1GHz, frequency coverage 30MHz–1GHz. Suitable for civil cabinets, ordinary computer rooms, office equipment and home appliances; economical configuration to satisfy basic EMC demands.
  • Standard Tier (Medium Grade): Shielding efficiency 60–90dB @1GHz, frequency coverage 30MHz–6GHz. Applied in industrial control, medical equipment, communication base stations, rail transit and data center cabinets; general high-reliability configuration balancing performance and cost.
  • Military Tier (High Grade): Shielding efficiency 90–120dB @1GHz, frequency coverage 30MHz–18GHz. Designed for military shelters, command centers, classified computer rooms, aerospace and high-precision laboratories; full-band high-shielding configuration complying with military standards such as GJB 151B.
image

Production Workshop

3.2 Classification by Functional Module

  • Sealing & Shielding Category: Shielding sealing strips, sealed shielding connectors, conductive gaskets. Resolve gap leakage and guarantee electrical continuity.
  • Ventilation & Shielding Category: Ventilation waveguide windows, ventilation waveguides. Balance heat dissipation, ventilation and electromagnetic shielding to block leakage at air vents.
  • Filter Protection Category: Power filters, signal filters, network filters, telephone filters, logic grounding filters. Suppress line interference and purify power, signal and grounding systems.
  • Interface Connection Category: RF shielding connectors, network/telephone shielding connectors, transition waveguides. Ensure electromagnetic isolation of interfaces and prevent signal leakage & external interference intrusion.

3.3 Classification by Application Scenario

  • Civilian / Ordinary Computer Room Dedicated: Basic-tier shielding sealing strips, simple ventilation waveguide windows, economical power/signal filters for low-cost basic protection.
  • Industrial / Medical / Communication Dedicated: Full series of standard-tier products with medium-high shielding, industrial-grade filtering, temperature & vibration resistance and IP54+ protection rating.
  • Military / Aerospace / Classified Dedicated: Full series of military-grade products with wideband high shielding, extreme environment adaptability, three-proof performance (salt spray/mold/sand dust) and 20G vibration resistance.
  • Data Center / Cabinet Dedicated: Standard-tier ventilation waveguide windows plus military-grade sealing strips & filters, supporting high-density heat dissipation, high shielding and pure signal transmission.

4. System Schematic Principle

External Electromagnetic Interference (30MHz–18GHz)

↓

Shielded Enclosure (All gaps sealed by shielding strips to block gap leakage)

↓

Air Vents → Ventilation Waveguide Window (Honeycomb cut-off structure attenuates electromagnetic waves by 30–120dB while maintaining ventilation)

↓

Power Input → Power Filter (Multi-stage LC filtering eliminates common-mode/differential-mode interference, insertion loss 30–90dB) → Equipment Power Terminal

↓

Network/Telephone/Signal Input → Network/Telephone/Signal Filter (Targeted filtering suppresses high-frequency clutter & crosstalk) → Shielding Connector (Electromagnetic sealing, contact resistance ≤1mΩ) → Equipment Interface

↓

Logic Ground / Protective Ground → Logic Grounding Filter (Low-impedance filtering, grounding impedance ≤1mΩ to purify ground potential) → Grounding Copper Bar → Earth

↓

High-Frequency RF Signals → Waveguide (Electromagnetically isolated transmission, shielding efficiency 70–120dB) → RF Equipment

Principle Explanation

The system adopts a four-layer protection architecture: multiple shielding + multi-stage filtering + grounding purification + ventilation cut-off.

  1. Shielding sealing strips block electromagnetic leakage at all gaps;
  2. Ventilation waveguide windows leverage waveguide cut-off characteristics to attenuate electromagnetic waves while maintaining ≥70% ventilation rate;
  3. Power/signal/network/telephone filters precisely eliminate interference on different types of lines;
  4. Logic grounding filters purify ground potential;
  5. Shielding connectors and waveguides deliver electromagnetic isolation for interfaces and high-frequency links.

The full-link design eliminates dead zones for electromagnetic interference and leakage suppression, achieving dual objectives of EMC compliance and information security.

image

Filter Installation on Cabinet

5. System Configuration List (Low/Medium/High Grade, Brand: KITOZER)

image

Internal Structure of Shielding Filter

5.1 Basic Tier Configuration List (30–60dB Shielding @1GHz)

表格

No.Product NameModelTechnical ParametersQtyUnitBrandRemarks
1Shielding Sealing StripKITOZER-SR-B1Rubber core + tin-plated phosphor bronze wire mesh; cross-section 10×5mm; shielding efficiency 30–40dB@1GHz; temperature range -20℃~80℃; compression rate 25%–40%; flame retardant UL94-HBOn-demandMeterKITOZERCabinet door & ordinary panel sealing
2Ventilation Waveguide WindowKITOZER-WV-B1Aluminum honeycomb + cold-rolled steel plate; 200×200mm; honeycomb aperture 6mm; waveguide length 20mm; shielding efficiency 40–50dB@1GHz; ventilation ≥80%; IP40 protectionOn-demandPieceKITOZERCabinet heat dissipation vents, ordinary computer room ventilation
3Basic WaveguideKITOZER-WG-B1Galvanized steel pipe; inner diameter 20mm; length 500mm; shielding efficiency 30–40dB@1GHz; frequency DC–1GHzOn-demandPieceKITOZERLow-frequency signal transmission, basic shielding
4Single-Phase Power FilterKITOZER-PF-B1Rated voltage 220V AC; rated current 10A; filter band 150kHz–30MHz; insertion loss ≥30dB@1MHz; leakage current ≤3.5mA; single-stage LC circuitOn-demandPieceKITOZERCivil equipment, ordinary cabinet power supply
5Signal Shielding ConnectorKITOZER-CON-B1RJ45/DB9 shielding connector; nickel-plated zinc alloy; contact resistance ≤5mΩ; shielding efficiency 30–40dB@1GHz; DC–1GHzOn-demandPieceKITOZEROrdinary signal interfaces, office equipment
6Basic Logic Grounding FilterKITOZER-GF-B1Grounding impedance ≤10mΩ; filter band DC–10MHz; rated current 20A; tin-plated copperOn-demandPieceKITOZEROrdinary computer rooms, non-classified equipment grounding
7Basic Network FilterKITOZER-NF-B1RJ45 interface; filter band 1MHz–100MHz; insertion loss ≥30dB@10MHz; isolation ≥40dB; 100Mbps compatibleOn-demandPieceKITOZEROrdinary office network, civil cabinet Ethernet ports
8Basic Telephone FilterKITOZER-TF-B1RJ11 interface; filter band DC–100kHz; insertion loss ≥20dB@50kHz; rated voltage 250V AC; 1 channelOn-demandPieceKITOZEROrdinary telephone lines, office equipment

5.2 Standard Tier Configuration List (60–90dB Shielding @1GHz)

表格

No.Product NameModelTechnical ParametersQtyUnitBrandRemarks
1Shielding Sealing StripKITOZER-SR-M1Silicone rubber core + silver-plated copper wire mesh; cross-section 12×6mm; shielding efficiency 60–70dB@1GHz; temperature -40℃~120℃; compression 25%–40%; UL94-V0 flame retardant; salt spray resistance ≥1000hOn-demandMeterKITOZERIndustrial cabinets, medical equipment, communication base stations
2Ventilation Waveguide WindowKITOZER-WV-M1Anodized aluminum honeycomb + stainless steel frame; 300×300mm; aperture 4mm; waveguide length 25mm; shielding efficiency 70–80dB@1GHz; ventilation ≥75%; IP54; DC–6GHzOn-demandPieceKITOZERIndustrial control, medical rooms, rail transit
3Standard WaveguideKITOZER-WG-M16061-T6 aluminum alloy; inner diameter 15mm; length 1000mm; shielding efficiency 70–80dB@1GHz; DC–10GHz; customizable elbows, anodizedOn-demandPieceKITOZERHigh-frequency signal transmission, industrial shielding, communication equipment
4Three-Phase Power FilterKITOZER-PF-M1Rated voltage 380V AC; rated current 30A; filter band 150kHz–100MHz; insertion loss ≥60dB@1MHz; leakage current ≤1mA; common-mode/differential-mode dual filtering; -40℃~85℃ wide temperatureOn-demandPieceKITOZERIndustrial equipment, medical devices, communication base stations
5RF Shielding ConnectorKITOZER-CON-M1SMA/N type; gold-plated beryllium copper; contact resistance ≤2mΩ; shielding efficiency 70–80dB@1GHz; DC–6GHz; IP54 waterproofOn-demandPieceKITOZERRF equipment, communication base stations, precision instruments
6Digital Signal FilterKITOZER-SF-M1RJ45/DB9; 1MHz–1GHz; insertion loss ≥50dB@100MHz; isolation ≥60dB; shielded RJ45, Gigabit compatibleOn-demandPieceKITOZERIndustrial Ethernet, data centers, medical equipment
7Enhanced Logic Grounding FilterKITOZER-GF-M1Grounding impedance ≤5mΩ; DC–100MHz; rated current 50A; silver-plated red copper; industrial grade; -40℃~120℃On-demandPieceKITOZERIndustrial computer rooms, precision equipment, rail transit
8Industrial Network FilterKITOZER-NF-M1RJ45; 1MHz–1GHz; insertion loss ≥50dB@100MHz; isolation ≥60dB; Gigabit/10G compatible, industrial gradeOn-demandPieceKITOZERIndustrial Ethernet, data center server ports
9Industrial Telephone FilterKITOZER-TF-M1RJ11; DC–1MHz; insertion loss ≥40dB@100kHz; 250V AC; 2 channels, lightning protection, industrial gradeOn-demandPieceKITOZERIndustrial telephones, fire alarm, intercom systems

5.3 Military Tier Configuration List (90–120dB Shielding @1GHz)

表格

No.Product NameModelTechnical ParametersQtyUnitBrandRemarks
1Shielding Sealing StripKITOZER-SR-H1Fluororubber core + Monel alloy wire mesh; cross-section 15×8mm; shielding efficiency 90–100dB@1GHz; -60℃~150℃; compression 25%–40%; salt spray ≥5000h; military flame retardantOn-demandMeterKITOZERMilitary shelters, command centers, classified computer rooms
2Ventilation Waveguide WindowKITOZER-WV-H1Silver-plated aluminum honeycomb + titanium alloy frame; 400×400mm; aperture 3mm; waveguide length 30mm; shielding efficiency 100–120dB@1GHz; 30MHz–18GHz; ventilation ≥70%; IP65; military grade, 20G vibration resistanceOn-demandPieceKITOZERMilitary shelters, aerospace, classified computer rooms
3Military-Grade WaveguideKITOZER-WG-H1Silver-plated titanium alloy; inner diameter 12mm; customizable length (1000mm standard); shielding efficiency 100–120dB@1GHz; DC–18GHz; 20G vibration resistance, customizable elbows of any angleOn-demandPieceKITOZERMilitary RF systems, aerospace, high-frequency shielding systems
4Broadband Power FilterKITOZER-PF-H1Wide voltage 220/380V AC; rated current 50A; filter band 150kHz–1GHz; insertion loss ≥90dB@1MHz; leakage current ≤0.1mA; multi-stage LC circuit, anti-pulse interference, three-proofOn-demandPieceKITOZERMilitary equipment, command centers, high-precision medical devices
5High-Isolation Shielding ConnectorKITOZER-CON-H1Military RF/signal connector; 5μm gold-plated beryllium copper alloy; contact resistance ≤1mΩ; shielding efficiency 100–110dB@1GHz; DC–18GHz; three-proof, IP67 waterproofOn-demandPieceKITOZERMilitary communication, aerospace, classified equipment
6Broadband Signal FilterKITOZER-SF-H1Military RF/analog signal filter; 1MHz–18GHz; insertion loss ≥80dB@100MHz; isolation ≥90dB; temperature stability ±0.5ppm/℃, three-proof military gradeOn-demandPieceKITOZERMilitary electronics, aerospace, precision test equipment
7Military Logic Grounding FilterKITOZER-GF-H1Grounding impedance ≤1mΩ; DC–1GHz; rated current 100A; rhodium-plated oxygen-free copper; military grade; -55℃~125℃, three-proofOn-demandPieceKITOZERMilitary computer rooms, command centers, classified systems
8Military Network FilterKITOZER-NF-H1Shielded RJ45; 1MHz–18GHz; insertion loss ≥80dB@100MHz; isolation ≥90dB; 10G compatible, three-proof military grade, anti-interferenceOn-demandPieceKITOZERMilitary networks, classified data transmission, command systems
9Military Telephone FilterKITOZER-TF-H1Shielded RJ11; DC–10MHz; insertion loss ≥60dB@1MHz; 300V AC; 4 channels, lightning & surge protection, three-proof military gradeOn-demandPieceKITOZERMilitary communication, classified telephones, command dispatch systems
10Military Conductive GasketKITOZER-GP-H1Beryllium copper elastic gasket; cross-section 0.8×1.6mm; compression 25%–40%; contact resistance ≤0.5mΩ; shielding efficiency 90–100dB@1GHz; three-proof military gradeOn-demandPieceKITOZEREnhanced sealing for waveguide windows, connectors and panel joints

6. Full Product Technical Specifications

image

Filter Wiring Installation

6.1 Shielding Sealing Strips

  • Basic Tier (KITOZER-SR-B1): Rubber core + tin-plated phosphor bronze wire mesh; cross-section 10×5mm; shielding efficiency 30–40dB@1GHz; -20℃~80℃; compression 25%–40%; UL94-HB flame retardant; contact resistance ≤8mΩ.
  • Standard Tier (KITOZER-SR-M1): Silicone rubber core + silver-plated copper wire mesh; cross-section 12×6mm; shielding efficiency 60–70dB@1GHz; -40℃~120℃; compression 25%–40%; UL94-V0 flame retardant; salt spray ≥1000h; contact resistance ≤3mΩ.
  • Military Tier (KITOZER-SR-H1): Fluororubber core + Monel alloy wire mesh; cross-section 15×8mm; shielding efficiency 90–100dB@1GHz; -60℃~150℃; compression 25%–40%; salt spray ≥5000h; military flame retardant; contact resistance ≤1mΩ.

6.2 Ventilation Waveguide Windows

  • Basic Tier (KITOZER-WV-B1): Aluminum honeycomb + cold-rolled steel plate; 200×200mm; aperture 6mm; waveguide length 20mm; shielding efficiency 40–50dB@1GHz; ventilation ≥80%; IP40; DC–1GHz.
  • Standard Tier (KITOZER-WV-M1): Anodized aluminum honeycomb + stainless steel frame; 300×300mm; aperture 4mm; waveguide length 25mm; shielding efficiency 70–80dB@1GHz; ventilation ≥75%; IP54; DC–6GHz.
  • Military Tier (KITOZER-WV-H1): Silver-plated aluminum honeycomb + titanium alloy frame; 400×400mm; aperture 3mm; waveguide length 30mm; shielding efficiency 100–120dB@1GHz; 30MHz–18GHz; ventilation ≥70%; IP65; 20G vibration resistance, military grade.

6.3 Waveguides

image

Control Console Equipped with Filters

  • Basic Tier (KITOZER-WG-B1): Galvanized steel pipe; inner diameter 20mm; length 500mm; shielding efficiency 30–40dB@1GHz; DC–1GHz, galvanized surface.
  • Standard Tier (KITOZER-WG-M1): 6061-T6 aluminum alloy; inner diameter 15mm; length 1000mm; shielding efficiency 70–80dB@1GHz; DC–10GHz; anodized, customizable elbows.
  • Military Tier (KITOZER-WG-H1): Silver-plated titanium alloy; inner diameter 12mm; customizable length (1000mm standard); shielding efficiency 100–120dB@1GHz; DC–18GHz; 20G vibration resistance, customizable elbows of any angle, military grade.

6.4 Power Filters

  • Basic Tier (KITOZER-PF-B1): 220V AC, 10A; filter band 150kHz–30MHz; insertion loss ≥30dB@1MHz; leakage current ≤3.5mA; single-stage LC; operating temperature 0℃~50℃.
  • Standard Tier (KITOZER-PF-M1): 380V AC, 30A; filter band 150kHz–100MHz; insertion loss ≥60dB@1MHz; leakage current ≤1mA; common-mode/differential-mode dual filtering; -40℃~85℃ wide temperature.
  • Military Tier (KITOZER-PF-H1): Wide voltage 220/380V AC, 50A; filter band 150kHz–1GHz; insertion loss ≥90dB@1MHz; leakage current ≤0.1mA; multi-stage LC circuit, anti-pulse interference, three-proof; -55℃~125℃ operating temperature.

6.5 Shielding Connectors

  • Basic Tier (KITOZER-CON-B1): RJ45/DB9; nickel-plated zinc alloy; contact resistance ≤5mΩ; shielding efficiency 30–40dB@1GHz; DC–1GHz; IP40.
  • Standard Tier (KITOZER-CON-M1): SMA/N type; gold-plated beryllium copper; contact resistance ≤2mΩ; shielding efficiency 70–80dB@1GHz; DC–6GHz; IP54 waterproof.
  • Military Tier (KITOZER-CON-H1): Military RF/signal connector; 5μm gold-plated beryllium copper alloy; contact resistance ≤1mΩ; shielding efficiency 100–110dB@1GHz; DC–18GHz; three-proof treatment, IP67 waterproof.

6.6 Signal Filters

  • Standard Tier (KITOZER-SF-M1): RJ45/DB9; 1MHz–1GHz; insertion loss ≥50dB@100MHz; isolation ≥60dB; shielded RJ45, Gigabit compatible, industrial grade.
  • Military Tier (KITOZER-SF-H1): Military RF/analog signal filter; 1MHz–18GHz; insertion loss ≥80dB@100MHz; isolation ≥90dB; temperature stability ±0.5ppm/℃, three-proof military grade.

6.7 Logic Grounding Filters

image

Filter Cabinet Installation Lineup

  • Basic Tier (KITOZER-GF-B1): Grounding impedance ≤10mΩ; DC–10MHz; rated current 20A; tin-plated copper; operating temperature 0℃~50℃.
  • Standard Tier (KITOZER-GF-M1): Grounding impedance ≤5mΩ; DC–100MHz; rated current 50A; silver-plated red copper, industrial grade; -40℃~120℃.
  • Military Tier (KITOZER-GF-H1): Grounding impedance ≤1mΩ; DC–1GHz; rated current 100A; rhodium-plated oxygen-free copper, military grade; -55℃~125℃, three-proof.

6.8 Network Filters

  • Basic Tier (KITOZER-NF-B1): RJ45; 1MHz–100MHz; insertion loss ≥30dB@10MHz; isolation ≥40dB; 100Mbps compatible, civil grade.
  • Standard Tier (KITOZER-NF-M1): RJ45; 1MHz–1GHz; insertion loss ≥50dB@100MHz; isolation ≥60dB; Gigabit/10G compatible, industrial grade.
  • Military Tier (KITOZER-NF-H1): Shielded RJ45; 1MHz–18GHz; insertion loss ≥80dB@100MHz; isolation ≥90dB; 10G compatible, three-proof military grade, anti-interference.

6.9 Telephone Filters

  • Basic Tier (KITOZER-TF-B1): RJ11; DC–100kHz; insertion loss ≥20dB@50kHz; 250V AC; 1 channel, civil grade.
  • Standard Tier (KITOZER-TF-M1): RJ11; DC–1MHz; insertion loss ≥40dB@100kHz; 250V AC; 2 channels, lightning protection, industrial grade.
  • Military Tier (KITOZER-TF-H1): Shielded RJ11; DC–10MHz; insertion loss ≥60dB@1MHz; 300V AC; 4 channels, lightning & surge protection, three-proof military grade.

6.10 Military Conductive Gasket

  • KITOZER-GP-H1: Beryllium copper elastic material; cross-section 0.8×1.6mm; compression 25%–40%; contact resistance ≤0.5mΩ; shielding efficiency ≥90dB@1GHz; three-proof military grade.
image

Batch Filter Products

7.1 Shielding Sealing Strips

  • Basic Tier: Civil cabinets, ordinary computer rooms, office equipment, home appliance shell gap sealing, indoor power distribution cabinets.
  • Standard Tier: Industrial control cabinets, medical equipment housings, communication base station cabinets, rail transit equipment cabin doors, data center cabinet door seams.
  • Military Tier: Military shelter door seams, shielding room joints of command centers, classified computer room cabin sealing, aerospace equipment housings, high-precision laboratory shielding enclosures.

7.2 Ventilation Waveguide Windows

  • Basic Tier: Heat dissipation vents of ordinary cabinets, civil computer room ventilation, office equipment cooling holes, home electronic device air vents.
  • Standard Tier: Industrial control cabinet heat dissipation, medical equipment cooling, communication base station ventilation, on-board rail transit equipment heat dissipation, top/side ventilation of data center cabinets.
  • Military Tier: Military shelter ventilation, aerospace equipment heat dissipation, classified computer room air exchange, high-precision laboratory cooling, shipboard/airborne electronic equipment heat dissipation.

7.3 Waveguides

  • Basic Tier: Low-frequency signal transmission, basic shielding cabinets, civil equipment electromagnetic isolation, indoor low-frequency RF circuits.
  • Standard Tier: Industrial high-frequency equipment, communication base stations, precision instruments, rail transit high-frequency signal transmission, data center high-frequency links.
  • Military Tier: Military RF systems, aerospace high-frequency equipment, classified high-frequency communication, high-precision test systems, satellite communication equipment.

7.4 Power Filters

  • Basic Tier: Home appliances, office equipment, ordinary cabinet power supply, consumer electronics, small civil devices.
  • Standard Tier: Industrial equipment, medical devices, communication base stations, rail transit, data center PDU power supply, industrial automation equipment.
  • Military Tier: Military equipment, command centers, high-precision medical devices, classified systems, aerospace equipment, military power supply systems.

7.5 Shielding Connectors

  • Basic Tier: Standard computer RJ45/DB9 ports, office equipment signal interfaces, civil cabinet connectors, consumer electronic device ports.
  • Standard Tier: Industrial network equipment, communication base station RF interfaces, medical equipment signal ports, precision instrument connectors, data center server Ethernet ports.
  • Military Tier: Military communication equipment, aerospace RF interfaces, classified equipment signal ports, high-frequency test instrument connectors, military command system interfaces.

7.6 Signal Filters

  • Standard Tier: Industrial Ethernet, data center server signals, medical equipment analog signals, precision instrument signals, industrial automation control signals.
  • Military Tier: Military electronic equipment, aerospace RF signals, classified system communication signals, high-frequency test equipment signals, military radar & communication system signals.

7.7 Logic Grounding Filters

  • Basic Tier: Ordinary computer rooms, non-classified equipment, civil cabinet grounding, indoor power distribution cabinet grounding, small civil device grounding.
  • Standard Tier: Industrial computer rooms, precision equipment, rail transit, medical devices, data center room grounding, industrial automation equipment grounding.
  • Military Tier: Military computer rooms, command centers, classified systems, high-precision laboratories, aerospace equipment, military command system grounding.

7.8 Network Filters

  • Basic Tier: Ordinary office networks, civil cabinet Ethernet ports, home routers/switches, small civil network devices.
  • Standard Tier: Industrial Ethernet, data center server ports, industrial automation networks, medical equipment networks, communication base station network devices.
  • Military Tier: Military networks, classified data transmission, command system networks, aerospace network equipment, military communication networks.

7.9 Telephone Filters

  • Basic Tier: Ordinary office telephones, civil telephone lines, landline phones, small civil intercom equipment.
  • Standard Tier: Industrial telephones, fire alarm systems, intercom doorbells, medical equipment telephone lines, communication base station telephone devices.
  • Military Tier: Military communication, classified telephones, command dispatch systems, aerospace communication equipment, military intercom systems.

8. Core Product Advantages

8.1 Core Functional Features

  1. Wideband High Shielding Performance: Basic tier 30–60dB, standard tier 60–90dB, military tier 90–120dB @1GHz; full frequency coverage 30MHz–18GHz to block electromagnetic leakage and interference, meeting EMC and information security standards.
  2. High-Efficiency Filter Purification: Power/signal/network/telephone filters adopt multi-stage LC/cavity shielded packaging structure, with maximum insertion loss up to 90dB, accurately eliminating common-mode, differential-mode, high-frequency clutter, crosstalk and surge interference to purify power, signal and grounding systems.
  3. Reliable Durable Sealing: Shielding strips adopt elastic cores wrapped with metal wire mesh, compression rate 25%–40%, contact resistance as low as 0.5mΩ, temperature range -60℃~150℃, maintaining stable sealing performance long-term and blocking gap leakage.
  4. Balanced Ventilation & Heat Dissipation: Honeycomb cut-off structure of waveguide windows delivers ventilation rate ≥70%, resolving the conflict between shielding and heat dissipation to avoid equipment overheating shutdown.
  5. Extreme Environment Adaptability: Military-grade products support temperature range -60℃~150℃, 20G vibration resistance, salt spray resistance ≥5000h, passing three-proof certification (salt spray/mold/sand dust), suitable for field, vehicle-mounted, airborne and shipboard harsh scenarios.
  6. Safe Isolated Interfaces: Gold/silver-plated shielding connectors with contact resistance as low as 1mΩ, high shielding efficiency, blocking electromagnetic leakage and interference intrusion at interfaces to guarantee secure signal transmission.

8.2 Full-Range Customization Capacity

  • Size Customization: Custom cross-section/length of sealing strips, dimensions/honeycomb aperture of waveguide windows, inner diameter/length/elbow angle of waveguides, interface type/pin definition of shielding connectors, fully tailored to client demands.
  • Material Customization: Custom rubber/silicone rubber/fluororubber cores, tin/silver/gold plating/Monel wire mesh, aluminum/titanium alloy/stainless steel/Monel alloy according to temperature resistance, corrosion resistance and three-proof requirements.
  • Performance Customization: Adjustable shielding efficiency (30–120dB), filter frequency band, temperature resistance range, vibration resistance grade (max 20G) and protection rating (IP40–IP67).
  • Interface Customization: Custom RJ45/DB9/SMA/N/military standard connectors; network/telephone filters compatible with all types of interfaces to match special equipment connection requirements.

8.3 OEM & ODM Processing Service

We provide full-series OEM/ODM manufacturing services. Mass production can be delivered per client drawings, samples and technical specifications, supporting small-batch trial production and large-volume delivery with strict quality control and short lead times. Processing coverage includes shielding sealing strips, ventilation waveguide windows, waveguides, power/signal/network/telephone/grounding filters and shielding connectors, offering one-stop processing solutions.

8.4 Confidentiality Guarantee

Sign military-grade non-disclosure agreements to strictly protect client drawings, technical parameters and customized solutions. Military-level confidentiality management prevents leakage of client information and design schemes to safeguard intellectual property and project security.

8.5 Spot Supply

Conventional basic & standard tier models are in stock for same-day delivery to rapidly respond to client demands. Military-grade products can be scheduled for production within 7–15 days to shorten project cycles for urgent projects.

8.6 Leading Industry Technical Indicators

  • Maximum military-grade shielding efficiency: 120dB @1GHz, full band 30MHz–18GHz (top-tier in the industry)
  • Operating temperature range: -60℃~150℃, adaptable to extreme cold and high-temperature environments
  • Minimum contact resistance: 0.5mΩ, excellent electrical conductivity to ensure continuous shielding
  • Maximum insertion loss: 90dB, thorough interference suppression
  • Maximum protection rating: IP67, dustproof and waterproof for harsh environments
  • Military vibration resistance: 20G, applicable to vehicle/airborne/shipboard scenarios
  • Minimum ventilation rate: ≥70%, perfect balance between shielding and heat dissipation

9. Bid Control Technical Parameters (Marked with *)

9.1 Shielding Sealing Strips

  • *Shielding efficiency: Basic ≥30dB, Standard ≥60dB, Military ≥90dB @1GHz
  • *Material: Basic – rubber core + tin-plated phosphor bronze mesh; Standard – silicone core + silver-plated copper mesh; Military – fluororubber core + Monel alloy mesh
  • *Temperature range: Basic -20℃~80℃; Standard -40℃~120℃; Military -60℃~150℃
  • *Compression rate: 25%–40% (key bid control parameter)
  • *Contact resistance: Basic ≤8mΩ; Standard ≤3mΩ; Military ≤1mΩ
  • *Flame retardant grade: Standard UL94-V0; Military military flame retardant standard

9.2 Ventilation Waveguide Windows

  • *Shielding efficiency: Basic ≥40dB; Standard ≥70dB; Military ≥100dB @1GHz
  • *Frequency range: Military 30MHz–18GHz (key bid control parameter)
  • *Honeycomb aperture: Basic ≤6mm; Standard ≤4mm; Military ≤3mm
  • *Waveguide length: Basic ≥20mm; Standard ≥25mm; Military ≥30mm
  • *Ventilation rate: ≥70% (key bid control parameter)
  • *Protection rating: Standard IP54; Military IP65
  • *Vibration resistance: Military ≥20G

9.3 Waveguides

  • *Shielding efficiency: Basic ≥30dB; Standard ≥70dB; Military ≥100dB @1GHz
  • *Frequency range: Standard DC–10GHz; Military DC–18GHz
  • *Material: Standard 6061-T6 aluminum alloy; Military silver-plated titanium alloy
  • *Inner diameter tolerance: ±0.5mm (key bid control parameter)

9.4 Power Filters

  • *Insertion loss: Basic ≥30dB; Standard ≥60dB; Military ≥90dB @1MHz (key bid control parameter)
  • *Filter band: Basic 150kHz–30MHz; Standard 150kHz–100MHz; Military 150kHz–1GHz
  • *Leakage current: Basic ≤3.5mA; Standard ≤1mA; Military ≤0.1mA (critical for medical & military applications)
  • *Rated voltage: Military supports wide voltage 220/380V AC
  • *Operating temperature: Military -55℃~125℃

9.5 Shielding Connectors

  • *Shielding efficiency: Basic ≥30dB; Standard ≥70dB; Military ≥100dB @1GHz
  • *Contact resistance: Basic ≤5mΩ; Standard ≤2mΩ; Military ≤1mΩ (key bid control parameter)
  • *Frequency range: Standard DC–6GHz; Military DC–18GHz
  • *Plating layer: Standard gold plating; Military 5μm thick gold plating + three-proof treatment
  • *Protection rating: Military IP67

9.6 Signal Filters

  • *Insertion loss: Standard ≥50dB; Military ≥80dB @100MHz (key bid control parameter)
  • *Isolation degree: Standard ≥60dB; Military ≥90dB
  • *Filter band: Standard 1MHz–1GHz; Military 1MHz–18GHz

9.7 Logic Grounding Filters

  • *Grounding impedance: Basic ≤10mΩ; Standard ≤5mΩ; Military ≤1mΩ (key bid control parameter)
  • *Rated current: Basic 20A; Standard 50A; Military 100A

9.8 Network Filters

  • *Insertion loss: Basic ≥30dB; Standard ≥50dB; Military ≥80dB @100MHz
  • *Isolation degree: Basic ≥40dB; Standard ≥60dB; Military ≥90dB
  • *Transmission rate compatibility: Standard Gigabit/10G; Military 10G + military anti-interference performance

9.9 Telephone Filters

  • *Insertion loss: Basic ≥20dB; Standard ≥40dB; Military ≥60dB @1MHz
  • *Channel quantity: Military ≥4 channels (key bid control parameter)

9.10 Military Conductive Gaskets

  • Contact resistance ≤0.5mΩ
  • Shielding efficiency ≥90dB @1GHz

10. Full-Scenario Product Solutions

10.1 Civilian / Ordinary Computer Room Solution (Basic Tier Configuration)

Demand

Low-cost basic electromagnetic protection, heat dissipation & ventilation, standard power/signal filtering and gap sealing.

Configuration

KITOZER-SR-B1 shielding strips (cabinet door & panel sealing) + KITOZER-WV-B1 ventilation waveguide windows (cabinet heat vents) + KITOZER-WG-B1 waveguides (low-frequency signals) + KITOZER-PF-B1 power filters (power input) + KITOZER-CON-B1 shielding connectors (signal ports) + KITOZER-GF-B1 logic grounding filters (grounding) + KITOZER-NF-B1 network filters (Ethernet ports) + KITOZER-TF-B1 telephone filters (telephone lines).

Effect

30–60dB shielding efficiency, eliminates basic power/signal interference, blocks leakage at gaps and air vents, meets EMC compliance and stable operation requirements for civil computer rooms.

10.2 Industrial / Medical / Communication Solution (Standard Tier Configuration)

Demand

Medium-high shielding, industrial-grade filtering, reliable sealing, balanced heat dissipation, temperature & vibration resistance, IP54+ protection, anti-vibration interference.

Configuration

KITOZER-SR-M1 shielding strips (equipment cabin doors & seams) + KITOZER-WV-M1 ventilation waveguide windows (equipment heat dissipation) + KITOZER-WG-M1 waveguides (high-frequency signals) + KITOZER-PF-M1 three-phase power filters (industrial power supply) + KITOZER-CON-M1 RF shielding connectors (communication ports) + KITOZER-SF-M1 signal filters (network/analog signals) + KITOZER-GF-M1 enhanced logic grounding filters (industrial grounding) + KITOZER-NF-M1 industrial network filters (industrial Ethernet) + KITOZER-TF-M1 industrial telephone filters (industrial telephones).

Effect

60–90dB shielding efficiency, full-band elimination of industrial interference, sealing temperature resistance -40℃~120℃, IP54 protection, 10G vibration resistance, meeting high-reliability EMC compliance and long-term stable operation demands for industrial, medical and communication scenarios.

10.3 Military / Aerospace / Classified Solution (Military Tier Configuration)

Demand

Military-grade high shielding, wideband filtering, extreme environment adaptability, three-proof performance (salt spray/mold/sand dust), 20G vibration resistance, classified information security, anti-pulse interference.

Configuration

KITOZER-SR-H1 shielding strips (shelter & classified computer room sealing) + KITOZER-WV-H1 ventilation waveguide windows (military equipment heat dissipation) + KITOZER-WG-H1 military waveguides (military high-frequency signals) + KITOZER-PF-H1 broadband power filters (military power supply) + KITOZER-CON-H1 high-isolation shielding connectors (military RF/signal ports) + KITOZER-SF-H1 broadband signal filters (classified communication signals) + KITOZER-GF-H1 military logic grounding filters (military grounding) + KITOZER-NF-H1 military network filters (military networks) + KITOZER-TF-H1 military telephone filters (classified telephones) + KITOZER-GP-H1 conductive gaskets (enhanced gap sealing).

Effect

90–120dB shielding efficiency (30MHz–18GHz), insertion loss ≥90dB, temperature range -60℃~150℃, 20G vibration resistance, passed GJB 151B military EMC certification, guaranteeing information security and stable equipment operation under extreme environments for military, aerospace and classified scenarios.

10.4 Data Center / Cabinet Integrated Solution (Standard + Military Tier Hybrid)

Demand

High-density heat dissipation, high shielding, power/signal/network filtering, cabinet sealing, pure grounding, prevention of signal crosstalk and information leakage.

Configuration

Standard-tier ventilation waveguide windows (cabinet heat dissipation, ventilation ≥75%) + military-grade shielding strips (cabinet door seams, shielding ≥90dB) + standard-tier power filters (rack PDU power supply, eliminate power interference) + military-grade signal/network filters (server signals & Ethernet ports, shielding ≥90dB) + standard-tier shielding connectors (network ports) + military-grade logic grounding filters (computer room grounding, grounding impedance ≤1mΩ).

Effect

70–100dB shielding efficiency, ventilation ≥75%, eliminates power/signal/network interference, blocks leakage at gaps and air vents, prevents signal crosstalk and data leakage between cabinets, ensuring stable operation of servers and network equipment.

10.5 Rail Transit On-Board Equipment Solution (Standard Tier Configuration)

Demand

Vibration resistance, temperature resistance (-40℃~120℃), shielding external electromagnetic interference, preventing on-board equipment signal leakage, 10G vibration resistance, IP54 protection.

Configuration

KITOZER-SR-M1 shielding strips (equipment cabin doors) + KITOZER-WV-M1 ventilation waveguide windows (equipment heat dissipation) + KITOZER-PF-M1 power filters (on-board power supply) + KITOZER-CON-M1 shielding connectors (signal ports) + KITOZER-GF-M1 logic grounding filters (on-board grounding) + KITOZER-NF-M1 network filters (on-board networks).

Effect

Passed vibration test (10G) and high-low temperature test (-40℃~120℃), measured shielding efficiency 70–80dB @1GHz; on-board communication operates stably without disconnection, interference or signal leakage during high-speed train operation.

11. Application Cases

11.1 Military Command Shelter Electromagnetic Shielding Project (Military Tier)

Project Background

A military land command shelter complying with GJB 151B military EMC standards, requiring shielding efficiency ≥100dB @1GHz, adapting to extreme field environments (-55℃~125℃, salt spray, sand dust, rain), to guarantee secure and stable communication of command systems.

Product Configuration

KITOZER-SR-H1 shielding strips (full sealing of shelter doors & seams) + KITOZER-WV-H1 ventilation waveguide windows (top & side heat dissipation) + KITOZER-WG-H1 waveguides (RF signal transmission) + KITOZER-PF-H1 broadband power filters (220V military power supply) + KITOZER-CON-H1 high-isolation shielding connectors (RF/network ports) + KITOZER-SF-H1 broadband signal filters (communication signals) + KITOZER-GF-H1 military logic grounding filters (shelter grounding) + KITOZER-NF-H1 military network filters (command networks) + KITOZER-TF-H1 military telephone filters (command telephones) + KITOZER-GP-H1 conductive gaskets (enhanced gap sealing).

Project Outcome

Measured shielding efficiency 105–115dB @1GHz, no full-band (30MHz–18GHz) leakage; passed GJB 151B certification; no corrosion after 5000h salt spray test, no loosening under 20G vibration; command systems maintain stable communication without electromagnetic interference or information leakage in field environments, receiving high recognition from military clients.

11.2 MRI Shielding Project of Grade A Tertiary Hospital (Standard Tier)

Project Background

3.0T MRI room of a top-tier hospital, requiring shielding of external electromagnetic interference to avoid image artifacts, while blocking internal RF signal leakage; shielding efficiency ≥70dB @1GHz, leakage current ≤1mA to guarantee medical equipment safety and clear imaging.

Product Configuration

KITOZER-SR-M1 shielding strips (room doors & wall seams) + KITOZER-WV-M1 ventilation waveguide windows (room heat dissipation) + KITOZER-PF-M1 three-phase power filters (380V medical power supply) + KITOZER-CON-M1 RF shielding connectors (equipment ports) + KITOZER-SF-M1 signal filters (MRI signals) + KITOZER-GF-M1 logic grounding filters (room grounding) + KITOZER-NF-M1 industrial network filters (medical networks).

Project Outcome

Measured shielding efficiency 75–85dB @1GHz, external electromagnetic interference attenuated by ≥80dB, clear MRI images without artifacts; leakage current 0.8mA, complying with medical equipment safety standards; stable room temperature, long-term fault-free equipment operation, meeting high-precision medical demands.

11.3 Large-Scale Data Center Cabinet Electromagnetic Protection Project (Standard + Military Hybrid)

Project Background

1,200 server cabinets for a large internet data center, requiring shielding of inter-cabinet electromagnetic interference, prevention of signal crosstalk and data leakage, and high-density heat dissipation; shielding efficiency ≥60dB @1GHz, ventilation rate ≥75%.

Product Configuration

KITOZER-SR-H1 shielding strips (cabinet door seams) + KITOZER-WV-M1 ventilation waveguide windows (top & side cabinet heat dissipation) + KITOZER-PF-M1 power filters (cabinet PDU power supply) + KITOZER-CON-M1 shielding connectors (server Ethernet ports) + KITOZER-SF-H1 broadband signal filters (server signals) + KITOZER-GF-H1 military logic grounding filters (computer room grounding) + KITOZER-NF-H1 military network filters (cabinet networks).

Project Outcome

Measured shielding efficiency 70–90dB @1GHz, inter-cabinet interference attenuated by ≥70% without signal crosstalk; ventilation ≥78%, cabinet temperature stabilized at 22–26℃; servers operate stably without shutdown or data leakage, boosting overall data center operational efficiency by 15%.

11.4 High-Speed Rail On-Board Communication Equipment Shielding Project (Standard Tier)

Project Background

Fuxing bullet train on-board communication equipment, requiring vibration & temperature resistance, shielding external electromagnetic interference to guarantee stable communication during operation; shielding efficiency ≥60dB @1GHz, 10G vibration resistance, temperature range -40℃~120℃.

Product Configuration

KITOZER-SR-M1 shielding strips (equipment cabin doors) + KITOZER-WV-M1 ventilation waveguide windows (equipment heat dissipation) + KITOZER-PF-M1 power filters (on-board 220V power supply) + KITOZER-CON-M1 shielding connectors (communication ports) + KITOZER-GF-M1 logic grounding filters (on-board grounding) + KITOZER-NF-M1 network filters (on-board networks).

Project Outcome

Passed 10G vibration and -40℃~120℃ high-low temperature tests, measured shielding efficiency 70–80dB @1GHz; stable on-board communication without disconnection, interference or signal leakage during 350km/h high-speed operation, guaranteeing train operation safety and passenger communication experience.

11.5 Classified Conference Room Electromagnetic Shielding Project (Military Tier)

Project Background

Government classified conference room requiring prevention of electromagnetic leakage (anti-eavesdropping of conference content), shielding efficiency ≥100dB @1GHz complying with classified information security standards, while maintaining ventilation and normal equipment operation.

Product Configuration

KITOZER-SR-H1 shielding strips (room doors & wall seams) + KITOZER-WV-H1 ventilation waveguide windows (air vents) + KITOZER-PF-H1 broadband power filters (power input) + KITOZER-CON-H1 high-isolation shielding connectors (equipment ports) + KITOZER-SF-H1 broadband signal filters (audio & video signals) + KITOZER-GF-H1 military logic grounding filters (room grounding) + KITOZER-NF-H1 military network filters (conference networks) + KITOZER-TF-H1 military telephone filters (conference telephones) + KITOZER-GP-H1 conductive gaskets (enhanced gap sealing).

Project Outcome

Measured shielding efficiency 100–110dB @1GHz, no full-band electromagnetic leakage, passed classified information security inspection; smooth ventilation and comfortable room temperature; stable audio & video equipment operation without interference, ensuring absolute security of classified conference information.

12. Product Faults & Maintenance Specifications

12.1 Common Faults & Troubleshooting

12.1.1 Shielding Sealing Strips

  1. Fault 1: Poor sealing, excessive electromagnetic leakage
    • Inspection causes: Aging/hardened/deformed strips, insufficient compression, oil/dust on contact surfaces, loose installation
    • Solution: Replace matching strips, adjust compression to 25%–40%, clean surfaces with anhydrous alcohol, apply conductive silicone grease, fasten installation buckles
  2. Fault 2: Cracked or fallen strips
    • Inspection causes: Material aging, over-stretching during installation, external pulling, acid/alkali solvent corrosion, over-temperature
    • Solution: Replace temperature/corrosion-resistant grade strips, standardize installation (max stretch ≤5%), isolate corrosive substances, apply three-proof coating, control ambient temperature
  3. Fault 3: Excessive contact resistance, reduced shielding efficiency
    • Inspection causes: Oxidized wire mesh, worn plating, unclean contact surfaces, insufficient compression
    • Solution: Clean contact surfaces, apply conductive silicone grease, replace gold/silver-plated strips, adjust compression ratio

12.1.2 Ventilation Waveguide Windows

  1. Fault 1: Declined shielding efficiency, excessive leakage
    • Inspection causes: Honeycomb clogged with dust, deformed frame, aged conductive gaskets, loose installation, worn honeycomb plating
    • Solution: Blow honeycomb dust with compressed air (≤0.5MPa), straighten frames, replace conductive gaskets, fasten mounting screws evenly (spacing ≤20mm), re-plate silver/gold
  2. Fault 2: Insufficient ventilation, equipment overheating
    • Inspection causes: Severe honeycomb blockage, overlong waveguide length, improper installation position, faulty fans
    • Solution: Thoroughly clean honeycomb, switch to shorter waveguide windows, adjust installation position for smooth air intake/exhaust, repair or replace fans
  3. Fault 3: Rusty/corroded frames
    • Inspection causes: Humid/salt spray environment, damaged protective coating
    • Solution: Polish and remove rust, re-spray three-proof coating, improve room ventilation, install moisture-proof covers

12.1.3 Waveguides

  1. Fault 1: Electromagnetic leakage, reduced shielding efficiency
    • Inspection causes: Loose connectors, deformed pipe walls, worn plating, poor sealing, unclean flange contact surfaces
    • Solution: Fasten connectors, straighten pipe walls, re-plate silver/gold, add conductive gaskets for sealing, clean flanges and apply conductive silicone grease
  2. Fault 2: High signal transmission loss, weak signals
    • Inspection causes: Dust/oil inside pipe, poor connector contact, mismatched model, excessive length
    • Solution: Clean inner walls with anhydrous alcohol, fasten connectors, switch to frequency-matched waveguides, shorten transmission length
  3. Fault 3: Cracked/deformed elbows
    • Inspection causes: Insufficient vibration resistance, external impact, material fatigue
    • Solution: Replace military vibration-resistant grade waveguides, install protective brackets, avoid physical impact

12.1.4 Power Filters

  1. Fault 1: Poor filtering effect, severe equipment interference
    • Inspection causes: Aging filters, insufficient rated current, poor grounding, wrong wiring, damaged internal components
    • Solution: Replace matching filters, switch to higher-current models, check grounding (impedance ≤5mΩ), rewire (distinguish live/neutral/ground), repair internal components
  2. Fault 2: Overheating, burnout or circuit tripping
    • Inspection causes: Overload (excessive current), short circuit, over-temperature environment, poor heat dissipation, broken internal components
    • Solution: Replace current-matching filters, troubleshoot line short circuits, improve ventilation cooling, lower ambient temperature, replace burnt filters
  3. Fault 3: Excessive leakage current, residual current device tripping
    • Inspection causes: Aging filters, damaged insulation, humid environment, poor grounding
    • Solution: Replace filters, repair insulation layers, improve moisture-proof treatment, optimize grounding system

12.1.5 Shielding Connectors

  1. Fault 1: Signal leakage, excessive interference
    • Inspection causes: Loose connectors, worn plating, excessive contact resistance, ungrounded shielding layer, unclean contact surfaces
    • Solution: Fasten connectors, replace gold/silver-plated connectors, clean contact surfaces and apply conductive silicone grease, ensure reliable grounding of shielding layers
  2. Fault 2: Signal interruption, unstable contact
    • Inspection causes: Deformed pins, aged fatigued internal shrapnel, violent plugging/unplugging, loose internal wiring
    • Solution: Straighten pins, replace connectors, standardize plugging operations, re-solder internal wiring
  3. Fault 3: Rust/corrosion, failed waterproof performance
    • Inspection causes: Humid/salt spray environment, insufficient protection rating, aged sealing rings
    • Solution: Polish and remove rust, switch to IP67 waterproof grade connectors, replace aged sealing rings, install moisture-proof covers

12.1.6 Signal / Network / Telephone Filters

  1. Fault 1: Excessive signal attenuation, abnormal transmission, slow network speed
    • Inspection causes: Mismatched filter model, aging, wrong wiring, damaged internal components
    • Solution: Replace filters matching frequency/transmission rate, install new filters, rewire, repair internal components
  2. Fault 2: Weak interference suppression, noisy signals
    • Inspection causes: Poor grounding, incomplete shielding, improper filter installation position, close proximity to high-power interference sources
    • Solution: Optimize grounding, complete interface shielding, install filters close to signal sources, keep distance from high-power interference equipment
  3. Fault 3: Disconnected network/telephone ports, no response
    • Inspection causes: Damaged ports, broken internal circuits, overload, electrostatic breakdown
    • Solution: Replace filters, rewire, troubleshoot overload causes, add anti-static protection

12.1.7 Logic Grounding Filters

  1. Fault 1: Excessive grounding resistance, severe ground potential interference, equipment crash
    • Inspection causes: Aging filters, overlong grounding cables, poor contact, corrosion, rusty grounding electrodes
    • Solution: Replace filters, shorten grounding cables (≤5m), clean contact surfaces, replace corroded parts, polish and re-connect grounding electrodes
  2. Fault 2: Broken grounding circuit, equipment electric leakage, safety hazards
    • Inspection causes: Internal open circuit, loose installation, external damage, burnout under overload
    • Solution: Replace filters, fasten mounting hardware, troubleshoot line faults, switch to higher-current models

12.2 Graded Maintenance Standards

12.2.1 Monthly Routine Maintenance (All Tiers)

  • Shielding strips: Visual inspection for aging/deformation/cracks, wipe dust & oil with soft cloth, check uniform sealing gaps
  • Ventilation waveguide windows: Blow honeycomb dust with compressed air, inspect frame/gasket integrity, fasten loose screws
  • Waveguides: Check connector tightness, visually inspect pipe/elbow deformation, clean outer walls
  • All filters (power/signal/network/telephone/grounding): Visual inspection for overheating/burnout/deformation, tightness of wiring terminals, grounding status, abnormal odors
  • Shielding connectors: Check connector tightness, plating integrity, no rust, smooth plugging & unplugging

12.2.2 Quarterly Maintenance (Standard & Military Tiers Only)

  • Shielding strips: Measure compression rate (25%–40%), test contact resistance with multimeter; replace severely aged (hardened/cracked) strips immediately
  • Ventilation waveguide windows: Spot-check shielding efficiency, clear stubborn blockages, replace aged conductive gaskets, straighten deformed frames
  • Waveguides: Test shielding efficiency, clean inner walls, fasten connectors and apply conductive silicone grease, inspect vibration resistance of elbows
  • Filters: Test insertion loss, grounding impedance and leakage current; replace products exceeding parameter standards, tighten wiring terminals
  • Shielding connectors: Measure contact resistance, clean contact surfaces and apply conductive silicone grease, replace connectors with severely worn plating

12.2.3 Annual Full Maintenance (Military Grade Only)

  • Full-series products: Comprehensive testing of shielding efficiency, electrical parameters and mechanical performance, issue official test reports
  • Shielding strips: Dismantle all strips for inspection; replace all aged/corroded/deformed products, re-install and adjust compression ratio
  • Ventilation waveguide windows: Disassemble and clean honeycomb cores, re-plate silver/gold, replace all conductive gaskets, re-install and seal
  • Filters: Complete aging testing and internal component inspection, replace aging components and calibrate parameters
  • Shielding connectors: Full disassembly, cleaning, re-gold plating, replace aged shrapnel, re-assemble and test
  • Grounding system: Full inspection of grounding resistance, grounding electrode status and circuit integrity, optimize grounding layout

12.2.4 Maintenance Taboos

  1. Do not scratch shielding strips, waveguide honeycomb cores or connector plating with sharp tools
  2. Do not clean products with strong acid/alkaline detergents; only anhydrous alcohol or neutral cleaners are permitted
  3. Do not violently plug/unplug connectors, over-stretch strips or impact waveguide elbows
  4. Do not deploy products without protection in long-term humid, salt spray or corrosive environments; regular three-proof treatment is required

13. Factory Strength & After-Sales Service

13.1 Factory Strength (KITOZER Brand)

  • Brand Positioning: KITOZER is a professional brand specializing in electromagnetic shielding and EMC filters, integrating R&D, production and sales of shielding connectors, sealing strips, ventilation waveguides and full-series filters, serving military, medical, data center, industrial control, rail transit and other industries.
  • Production Base: 20,000 ㎡ modern manufacturing base located in Guangzhou, Guangdong Province, equipped with automated production lines, precision processing equipment and a shielding efficiency testing laboratory covering 30MHz–18GHz, with annual output of 5 million sets of shielding & filtering products.
  • Technical Team: Core technical team with over 20 years of electromagnetic shielding industry experience, participating in drafting multiple national and military standards, holding 30 invention patents and 50 utility model patents, mastering core technologies of wideband shielding, high-efficiency filtering and durable sealing.
  • Quality Certifications: ISO9001 Quality Management System, ISO14001 Environmental Management System, ISO45001 Occupational Health & Safety Management System, military three-certificate qualification, GJB 151B certification; products comply with national standard GB/T 37429-2019 and military standard GJB 151B.
  • Supply Chain: Military-grade raw material supply chain; core materials (Monel alloy, titanium alloy, oxygen-free copper, fluororubber) sourced from top domestic and international brands to guarantee product quality from the source.
  • Customization Capacity: Full-process customized services including scheme design, structural optimization, material selection, sample trial production and mass manufacturing; drawings delivered within 7 days, samples within 15 days, mass production within 30 days to meet personalized client demands.

13.2 After-Sales Service (Unified Standard for All Tiers, Upgraded for Military Grade)

13.2.1 Pre-Sales Service

  1. Free technical consultation: 7×24 professional technical team online to answer questions on product selection, technical parameters and scheme design
  2. Free customized scheme design: Personalized shielding & filtering solutions tailored to client scenarios (civil/industrial/military), shielding demands and equipment parameters, complete with drawings and technical quotations
  3. Free sample testing: Supply free samples for client on-site testing of shielding efficiency and filtering performance; mass order confirmed only after satisfactory testing results
  4. On-site survey: Free on-site electromagnetic environment survey for large-scale projects (classified computer rooms, military shelters, data centers) to optimize scheme design

13.2.2 In-Sales Service

  1. Transparent production progress: Real-time production progress updates with photos/videos for client supervision
  2. Full-process quality control: 100% inspection of shielding efficiency, electrical parameters and mechanical performance before delivery, complete factory test reports provided
  3. Professional packaging & logistics: Military-grade shockproof & moisture-proof packaging, cooperating with SF Express & Deppon Logistics with full cargo insurance to ensure intact delivery
  4. Free installation guidance: Remote or on-site professional technical guidance, complete installation drawings & videos to standardize installation operations

13.2.3 After-Sales Core Guarantee

  1. Warranty Period: Basic tier 1 year, standard tier 2 years, military tier 3 years; free repair, free spare part replacement and free on-site service for large projects within warranty
  2. Response Speed: 7×24 after-sales hotline, response within 1 hour, solution issued within 4 hours, on-site service within 24 hours nationwide; military projects on-site support within 4 hours
  3. Lifetime Maintenance: Cost-only maintenance after warranty expiration, regular follow-up visits with maintenance reminders and upgrade transformation services
  4. Free Technical Training: Free on-site or online training on product installation, operation and maintenance for clients to realize independent operation
  5. Quality Commitment: Free replacement of new products for non-artificial quality damage within warranty, unconditional return & exchange for quality defects with round-trip freight borne by our company
  6. Exclusive Military Service: Dedicated one-on-one technical team for military projects with full-cycle tracking, regular on-site inspections and customized military-grade maintenance plans to guarantee stable operation under extreme environments

14. Conclusion

KITOZER’s shielding connector, sealing strip and ventilation waveguide solution forms a full-scenario electromagnetic shielding & filtering system covering civil basic protection up to military classified security, with core strengths of full product coverage, graded performance matching, wideband high shielding, high-efficiency filtering, durable sealing, extreme environment adaptability and customized services.

Nine core products work collaboratively to block electromagnetic interference and information leakage from six dimensions: gap sealing, ventilation shielding, interface isolation, power purification, signal filtering and grounding protection, helping all industries achieve three core objectives: EMC compliance, stable equipment operation and information security protection.

Backed by 20 years of technical accumulation, modern manufacturing base, military-grade quality control and full-cycle premium after-sales service, KITOZER products have been widely deployed in military, aerospace, medical, data center, rail transit and industrial control sectors, winning consistent recognition and high praise from clients. Moving forward, KITOZER will continue to deepen the electromagnetic shielding & EMC filtering industry, pursue technological innovation, quality upgrading and service optimization, and provide more premium, efficient and reliable electromagnetic shielding & filtering solutions for global clients, acting as the core guardian of electromagnetic information security and stable equipment operation.

15. SEO & Tag System

15.1 Core Keyword System

  1. Primary Core Keywords: shielding connector, shielding sealing strip, ventilation waveguide window, electromagnetic shielding solution, EMC filtering system
  2. High-Conversion Long-Tail Keywords: military-grade shielding connector, industrial shielding sealing strip, computer room ventilation waveguide window, classified computer room shielding solution, data center electromagnetic shielding system, power filter manufacturer, customized signal filter
  3. Industry Traffic Keywords: electromagnetic shielding material, EMI filter, shielding room construction, cabinet shielding solution, EMC compatibility solution, waveguide manufacturer, logic grounding filter
  4. Brand Exclusive Keywords: KITOZER shielding connector, KITOZER sealing strip, KITOZER ventilation waveguide, KITOZER filter, KITOZER electromagnetic shielding solution
  5. Drop-Down & Related Search Keywords: shielding connector specifications, shielding sealing strip price, ventilation waveguide window shielding efficiency, electromagnetic shielding solution manufacturer, EMC filtering system configuration, military shielding filter, network & telephone filter

15.2 SEO Optimization Tag System

  1. Core Page Optimization Tag: shielding connector_shielding sealing strip_ventilation waveguide window_electromagnetic shielding solution_KITOZER
  2. Title Tag: KITOZER Shielding Connector / Sealing Strip / Ventilation Waveguide Solution_Military/Industrial/Computer Room Electromagnetic Shielding Filter System
  3. Meta Keywords: shielding connector, shielding sealing strip, ventilation waveguide window, electromagnetic shielding solution, EMC filtering system, KITOZER, power filter, signal filter, waveguide, classified computer room shielding
  4. Meta Description: KITOZER provides full-series shielding connectors, shielding sealing strips, ventilation waveguide windows and power/signal/network/telephone/grounding filters with graded low/medium/high configurations and military-grade shielding efficiency, customized electromagnetic shielding solutions applicable to military, medical, data center and industrial control scenarios.
  5. H1 Tag: KITOZER Shielding Connector / Sealing Strip / Ventilation Waveguide Solution (Full-Series Electromagnetic Shielding Filter Products)
  6. H2 Tags: System Overview, System Composition, System Classification, System Schematic Principle, System Configuration List, Full Product Technical Specifications, Full Product Application Scope, Core Product Advantages, Bid Control Technical Parameters, Full-Scenario Product Solutions, Application Cases, Product Faults & Maintenance Specifications, Factory Strength & After-Sales Service, Conclusion
  7. Internal Link Anchor Text Tags
    • Core Anchors: shielding connector, shielding sealing strip, ventilation waveguide window, electromagnetic shielding solution
    • Long-Tail Anchors: military-grade shielding connector, industrial shielding sealing strip, computer room ventilation waveguide window, classified computer room shielding solution
    • Related Anchors: power filter, signal filter, waveguide, logic grounding filter, network filter, telephone filter
Shopping Cart