Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32
KITOZER
KITOZER

KITOZER Power Distribution Switching System

Table of Contents

1. System Overview

The KITOZER power distribution switching system is a core power supporting system integrating electric energy distribution, safety protection, intelligent monitoring and remote control. As a critical connecting device between power transmission and power consumption sides, it undertakes core functions including rational electric energy allocation, load regulation, rapid fault breaking and energy consumption monitoring.

Complying strictly with national and industrial standards such as GB 7251, GB/T 19964 and DL/T 404, the system covers full scenarios including high voltage (10–35kV), low voltage (400V), new energy grid connection and precision power distribution. It meets power demand across multiple sectors: industrial plants, commercial buildings, data centers, photovoltaic/wind power stations, rail transit and municipal engineering.

Breaking the single on-off mode of traditional switches, the system integrates Internet of Things (IoT), intelligent sensing and communication technologies to support dual local/remote monitoring. It collects real-time operational data including voltage, current, power, temperature & humidity and switch status, and delivers functions such as fault early warning, remote closing/opening, energy consumption statistics & analysis, and harmonic governance. It features five core strengths: high safety, high reliability, strong compatibility, easy maintenance and customizable design. Customized development can be carried out according to load power, power supply grade and environmental conditions (high/low temperature, humidity, salt spray, dust) to ensure safe, stable, efficient and intelligent operation of power systems.

2. System Composition

The KITOZER power distribution switching system consists of four modules: primary core equipment, secondary control & protection equipment, auxiliary supporting equipment, and intelligent monitoring & communication equipment. All modules work collaboratively to form a complete electric energy distribution and protection chain.

2.1 Primary Core Equipment (Core for Power On-Off & Protection)

  • High voltage switches: Vacuum circuit breakers, load break switches, disconnectors, earthing switches, fuse combination units
  • Low voltage switches: Air circuit breakers (ACB), moulded case circuit breakers (MCCB), miniature circuit breakers (MCB), automatic transfer switches (ATS), disconnectors, fuse-switch disconnectors
  • Supporting components: Current transformers, voltage transformers, zinc oxide surge arresters, main busbars, branch busbars, cable connectors

2.2 Secondary Control & Protection Equipment (Control & Protection Hub)

  • Microcomputer protection devices, intelligent trip units, relays, contactors, fuses, control push buttons, indicator lights, transfer switches
  • Measuring instruments: Multi-function power meters, ammeters, voltmeters, power meters, energy meters

2.3 Auxiliary Supporting Equipment (Safety & Installation Support)

  • Cabinets: High voltage switchgears (KYN28, HXGN), low voltage power distribution cabinets (GGD, MNS, GCS), distribution boxes, control cabinets
  • Accessories: Insulating supports, earthing bars, terminal blocks, trunking, cooling fans, dust screens, door locks, sealing strips

2.4 Intelligent Monitoring & Communication Equipment (Digital Operation & Maintenance Core)

  • Intelligent monitoring modules: Temperature & humidity sensors, smoke detectors, water immersion sensors, vibration sensors
  • Communication devices: RS485 communication modules, Ethernet modules, wireless transmission modules (4G/5G/Wi-Fi)
  • Management platforms: Local touch screens, remote monitoring platforms, mobile APPs for data visualization and remote control

3. System Classification

The KITOZER power distribution switching system is classified by five dimensions: voltage grade, installation scenario, functional characteristics, rated current and operation mode, enabling precise adaptation to diverse scenarios.

3.1 Classification by Voltage Grade

  • High voltage power distribution switching system (10kV/35kV): Applicable to power substations, industrial & mining enterprises, photovoltaic and wind power stations for high voltage power transmission and distribution. Core components include vacuum circuit breakers, load break switches and disconnectors, featuring high insulation and high breaking capacity.
  • Low voltage power distribution switching system (AC400V/690V): Applicable to industrial plants, commercial buildings, data centers and civil buildings for terminal power distribution. Core components include air circuit breakers, moulded case circuit breakers and miniature circuit breakers, featuring compact structure, intelligent functions and easy operation.

3.2 Classification by Installation Scenario

  • Indoor type: For power distribution rooms, machine rooms and control rooms. Protection grade IP20–IP40, compact structure with excellent heat dissipation.
  • Outdoor type: For municipal power lines, photovoltaic power stations, ports and mining areas. Protection grade IP54–IP65, with rainproof, dustproof, salt spray resistant, anti-aging and wide temperature resistance properties.
  • Cabinet-mounted type: For installation inside power distribution cabinets, control cabinets and distribution boxes. Modular design for easy integration and maintenance.

3.3 Classification by Functional Characteristics

  • Basic protection type: Equipped with overload, short-circuit and earth fault protection. Simple structure and cost-effective, suitable for non-critical loads such as general lighting and sockets.
  • Intelligent monitoring type: Integrated power monitoring, temperature & humidity monitoring, switch status monitoring and communication functions, supporting remote monitoring and fault early warning. Ideal for data centers, precision equipment and critical loads.
  • Dual power automatic transfer type: Supports automatic switching between dual mains power or mains + diesel generator, with switching time ≤0.5s to ensure zero power interruption. Designed for high-reliability scenarios including data centers, hospitals and financial institutions.
  • New energy grid-connected type: Adapted to grid connection of photovoltaic, wind power and energy storage systems, with anti-reflux, harmonic governance, overvoltage and overcurrent protection to support multi-source integrated power distribution.

3.4 Classification by Rated Current

  • Low current type (≤63A): Miniature circuit breakers and small disconnectors, for terminal lighting, sockets and small equipment power supply.
  • Medium current type (63A–1600A): Moulded case circuit breakers and load break switches, for floor power distribution, workshop branch circuits and medium & small equipment power supply.
  • High current type (≥1600A): Air circuit breakers and high voltage vacuum circuit breakers, for power distribution room incoming lines, main busbars and large industrial & mining enterprises.

3.5 Classification by Operation Mode

  • Manual operation type: Manual closing and opening, simple structure and low cost, for scenarios with low operation frequency and no remote control demand.
  • Electric operation type: Electric closing and opening, supporting remote and automatic control, for scenarios with high operation frequency and automated remote operation & maintenance requirements.
  • Intelligent operation type: Integrated intelligent control modules for automatic switching, fault linkage and remote programming, for intelligent power distribution and unattended scenarios.

4. System Schematic Diagrams

4.1 Low Voltage Power Distribution Switching System Schematic (AC400V)

Primary Circuit Principle

Mains power / new energy source → incoming disconnector → air circuit breaker (main switch with overload/short-circuit/earth fault protection) → main busbar → moulded case circuit breakers (branch switches) → miniature circuit breakers for sub-circuits → loads (lighting, sockets, motors, precision equipment).

For dual power scenarios: Dual mains power → ATS automatic transfer switch → air circuit breaker → main busbar → branch switches → loads.

Secondary Circuit Principle

Control power supply → control push buttons / transfer switches → relay / contactor coils → circuit breaker closing & opening coils → circuit breaker auxiliary contacts → indicator lights (closed/open/fault) → microcomputer protection device (collects current & voltage signals to trigger tripping upon faults).

Intelligent Monitoring Principle

Current / voltage transformers → multi-function power meter → RS485 / Ethernet communication module → local touch screen / remote monitoring platform; temperature & humidity / smoke / water immersion sensors → monitoring module → communication module → platform, enabling data collection, display, early warning and remote control.

4.2 High Voltage Power Distribution Switching System Schematic (10kV)

Primary Circuit Principle

High voltage power supply → incoming disconnector → vacuum circuit breaker (main switch with instantaneous overcurrent / overcurrent / earth fault protection) → main busbar → current transformers → voltage transformers → zinc oxide surge arresters → outgoing disconnector → cables → loads / transformers.

Secondary Circuit Principle

Control power supply → microcomputer protection device → circuit breaker closing & opening coils → circuit breaker auxiliary contacts → indicator lights / alarm devices. The protection device collects transformer signals and trips the circuit breaker rapidly upon faults (short-circuit, overload, earth fault), while uploading fault signals to the monitoring platform.

5. Complete System Configuration List (KITOZER Brand, Divided into Basic, Medium & High-End Grades)

5.1 Basic Low-End Type (General Lighting / Civil Buildings / Non-Critical Loads)

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1Miniature Circuit Breaker (MCB)KIT-MCB-63/1PRated voltage AC230V, rated current 6–63A, breaking capacity 6kA, C/D trip curve, IP20As requiredSetKITOZERLighting & socket circuits
2Miniature Circuit Breaker (MCB)KIT-MCB-63/2PRated voltage AC400V, rated current 6–63A, breaking capacity 6kA, C/D trip curve, IP20As requiredSetKITOZERSingle-phase equipment circuits
3DisconnectorKIT-IS-100/3PRated voltage AC400V, rated current 100A, insulation voltage 1000V, IP30, manual operation1SetKITOZERMain isolating switch
4Low Voltage Distribution BoxKIT-DB-400/200/500Dimension 400×200×500mm, cold-rolled steel plate, plastic spraying, IP30, indoor installation1SetKITOZERIndoor surface mounting
5Copper BusbarKIT-BUS-400ATinned pure copper, rated current 400A, voltage resistance 1kVAs requiredMeterKITOZERMain & branch busbars
6Terminal BlockKIT-TB-2.5-16Suitable for 2.5–16mm² cables, flame-retardant insulation, copper materialAs requiredPieceKITOZERCable connection

5.2 Medium-End Intelligent Type (Industrial Plants / Commercial Buildings / General Critical Loads)

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1Moulded Case Circuit Breaker (MCCB)KIT-MCCB-250/3PRated voltage AC400V/690V, rated current 100–250A, breaking capacity 25kA, thermal-magnetic trip, IP30As requiredSetKITOZERWorkshop branch & floor main switches
2Moulded Case Circuit Breaker (MCCB)KIT-MCCB-400/3PRated voltage AC400V/690V, rated current 250–400A, breaking capacity 35kA, thermal-magnetic trip, IP30As requiredSetKITOZERPower distribution room branch switches
3Automatic Transfer Switch (ATS)KIT-ATS-250/3PRated voltage AC400V, rated current 250A, switching time ≤0.5s, auto/manual switching, IP301SetKITOZERDual mains power switching
4Intelligent Multi-Function Power MeterKIT-PM-96Measures voltage, current, power, energy, power factor, frequency; 0.5S accuracy class, RS485 communication, MODBUS protocol1SetKITOZEREnergy consumption monitoring
5Low Voltage Power Distribution Cabinet (GGD)KIT-GGD-800/600/2200Dimension 800×600×2200mm, cold-rolled steel plate, plastic spraying, IP30, indoor installation with cooling fan1SetKITOZERMain cabinet for power distribution room
6Current TransformerKIT-CT-300/5Rated voltage AC400V, ratio 300/5A, 0.5S accuracy class, voltage resistance 2kVAs requiredSetKITOZERCurrent sampling
7Temperature & Humidity SensorKIT-TH-100Temperature range -20℃~60℃, humidity 0–100% RH, accuracy ±0.5℃/±3% RH, RS485 communication1SetKITOZERCabinet internal monitoring
8Remote Communication ModuleKIT-COM-RS485RS485 to Ethernet, supports MODBUS-TCP, DC24V power supply1SetKITOZERData upload

5.3 High-End Intelligent Redundant Type (Data Centers / Photovoltaic Power Stations / High Voltage Scenarios / Core Critical Loads)

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1Air Circuit Breaker (ACB)KIT-ACB-630/3PRated voltage AC400V/690V, rated current 400–630A, breaking capacity 50kA, intelligent trip unit with communication, IP401SetKITOZERMain switch for data centers
2Air Circuit Breaker (ACB)KIT-ACB-1250/3PRated voltage AC400V/690V, rated current 800–1250A, breaking capacity 80kA, intelligent trip unit with communication, IP401SetKITOZERIncoming switch for photovoltaic power stations
3High Voltage Vacuum Circuit BreakerKIT-VCB-12/630Rated voltage 12kV, rated current 630A, short-circuit breaking capacity 20kA, mechanical life ≥10,000 times, IP4X1SetKITOZERCore component of 10kV high voltage cabinet
4Microcomputer Protection DeviceKIT-PRO-100Overcurrent / instantaneous overcurrent / earth / overvoltage / undervoltage protection, fault recording, RS485/Ethernet communication, DC220V power supply1SetKITOZERProtection for high & low voltage systems
5Low Voltage Precision Power Distribution CabinetKIT-LT-AC-1250Dimension 1000×800×2200mm, cold-rolled steel plate, plastic spraying, IP40, precision monitoring, dual busbar design1SetKITOZERRow cabinet for data centers
6High Voltage Switchgear (KYN28)KIT-KYN28-12Dimension 800×1500×2200mm, metal-clad withdrawable type, IP4X, five-proof interlock, 10kV system1SetKITOZER10kV power distribution room
7Zinc Oxide Surge ArresterKIT-YH5WZ-17/45Rated voltage 17kV, residual voltage ≤45kV, discharge current 40kA, lightning overvoltage protection2SetKITOZERHigh voltage cabinet / incoming cabinet
8Intelligent Remote Monitoring PlatformKIT-SC-2000Data visualization, remote switching operation, fault early warning, energy consumption analysis, multi-terminal compatibility (WEB/APP)1SetKITOZERCore for system operation & maintenance
9Surge Protection Device (SPD)KIT-SPD-40/3P+NRated voltage AC400V, maximum discharge current 40kA, protection level ≤1.5kV, lightning protection1SetKITOZERPower supply lightning protection

6. Full Product Technical Parameters

6.1 Low Voltage Miniature Circuit Breaker (KIT-MCB Series)

  • Rated voltage: AC230V/400V
  • Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
  • Breaking capacity: 6kA (standard), 10kA (high breaking capacity)
  • Trip curves: Curve C (5–10In, lighting & general loads), Curve D (10–16In, motors & inductive loads)
  • Pole types: 1P, 2P, 3P, 4P
  • Protection grade: IP20
  • Mechanical life: ≥10,000 operations
  • Electrical life: ≥8,000 operations
  • Operating environment: Temperature -5℃~40℃, humidity ≤95% RH (non-condensing)

6.2 Low Voltage Moulded Case Circuit Breaker (KIT-MCCB Series)

  • Rated voltage: AC400V/690V
  • Rated current: 100A, 160A, 200A, 250A, 400A, 630A
  • Breaking capacity: 25kA (standard), 35kA (medium-high breaking capacity), 50kA (high breaking capacity)
  • Trip modes: Thermal-magnetic trip (overload + short-circuit), intelligent trip (adjustable + communication)
  • Pole types: 3P, 4P
  • Protection grade: IP30
  • Mechanical life: ≥8,000 operations
  • Electrical life: ≥5,000 operations
  • Operating environment: Temperature -5℃~40℃, humidity ≤95% RH (non-condensing)

6.3 Low Voltage Air Circuit Breaker (KIT-ACB Series)

  • Rated voltage: AC400V/690V
  • Rated current: 400A, 630A, 800A, 1000A, 1250A, 1600A
  • Breaking capacity: 50kA (standard), 80kA (high breaking capacity), 100kA (ultra-high breaking capacity)
  • Trip mode: Intelligent electronic trip (overload, short-circuit, earth fault, phase loss, unbalance protection, remotely adjustable)
  • Pole types: 3P, 4P
  • Protection grade: IP40
  • Mechanical life: ≥10,000 operations
  • Electrical life: ≥6,000 operations
  • Communication functions: Supports MODBUS-RTU/TCP, Profinet
  • Operating environment: Temperature -10℃~50℃, humidity ≤95% RH (non-condensing)

6.4 Automatic Transfer Switch (KIT-ATS Series)

  • Rated voltage: AC400V
  • Rated current: 100A, 250A, 400A, 630A, 1250A
  • Switching time: ≤0.5s (mains to mains), ≤1s (mains to diesel generator)
  • Switching modes: Automatic (mains priority), manual
  • Protection functions: Overvoltage, undervoltage, phase loss, undervoltage loss protection
  • Pole types: 3P, 4P
  • Protection grade: IP30
  • Mechanical life: ≥5,000 operations
  • Operating environment: Temperature -5℃~40℃, humidity ≤95% RH (non-condensing)

6.5 High Voltage Vacuum Circuit Breaker (KIT-VCB Series, 10kV)

  • Rated voltage: 12kV
  • Rated current: 630A, 1250A, 1600A
  • Rated frequency: 50Hz
  • Short-circuit breaking current: 20kA, 25kA, 31.5kA
  • Rated short-circuit making current (peak): 50kA, 63kA, 80kA
  • Mechanical life: ≥10,000 operations
  • Protection grade: IP4X
  • Operation modes: Electric / manual
  • Operating environment: Temperature -10℃~40℃, altitude ≤2000m, humidity ≤95% RH (non-condensing)

6.6 Microcomputer Protection Device (KIT-PRO Series)

  • Applicable voltage: AC400V (low voltage), 10kV/35kV (high voltage)
  • Protection functions: Overcurrent, instantaneous overcurrent, earth fault, overvoltage, undervoltage, phase loss, unbalance, overheating protection
  • Measurement accuracy: Current / voltage 0.5S class, power 0.5 class
  • Communication interfaces: RS485 (MODBUS-RTU), Ethernet (MODBUS-TCP)
  • Power supply: DC220V/AC220V
  • Fault recording: ≥100 records with time stamps
  • Operating environment: Temperature -20℃~60℃, humidity ≤95% RH (non-condensing)

6.7 Intelligent Multi-Function Power Meter (KIT-PM-96)

  • Measurable parameters: Voltage, current, active power, reactive power, apparent power, power factor, frequency, active energy, reactive energy
  • Accuracy class: Voltage / current 0.5S class, power 0.5 class, energy 0.5S class
  • Communication interface: RS485, MODBUS-RTU protocol
  • Display mode: LED/LCD
  • Power supply: AC/DC85–265V
  • Operating environment: Temperature -10℃~50℃, humidity ≤95% RH (non-condensing)

7. Full Product Application Scope

7.1 Low Voltage Miniature Circuit Breaker (KIT-MCB Series)

  • Civil buildings: Lighting and socket circuits for residences, apartments and villas
  • Commercial premises: Office lighting and small equipment power supply for shopping malls, hotels and office buildings
  • Industrial scenarios: Workshop lighting, small motors, instruments and control circuits
  • Others: Installation inside distribution boxes and control cabinets

7.2 Low Voltage Moulded Case Circuit Breaker (KIT-MCCB Series)

  • Industrial plants: Workshop branch power distribution, medium & small motor (15–110kW) power supply, machine tool equipment
  • Commercial buildings: Floor main power distribution, central air conditioning, elevators, water pumps and other large equipment power supply
  • Municipal engineering: Street lighting power distribution, small pump stations, community power distribution rooms
  • Data centers: Branch circuits of row cabinets, front-stage protection for cabinet PDUs

7.3 Low Voltage Air Circuit Breaker (KIT-ACB Series)

  • Data centers: Main incoming lines of machine rooms, front ends of UPS, main switches of precision power distribution cabinets
  • Large industrial & mining enterprises: Factory main power distribution rooms, main busbars, large motors (≥160kW) power supply
  • Photovoltaic / wind power stations: Inverter output terminals, main switches of grid-connected cabinets, power distribution for energy storage systems
  • Commercial complexes: Main power distribution for shopping malls, hotels and office buildings, emergency power switching

7.4 Automatic Transfer Switch (KIT-ATS Series)

  • High-reliability scenarios: Data centers, hospital operating rooms, ICUs, financial institution machine rooms
  • Emergency power supply scenarios: Fire water pumps, smoke exhaust fans, emergency lighting, elevators
  • Critical loads: Servers, precision instruments, industrial automated production lines, communication base stations

7.5 High Voltage Vacuum Circuit Breaker (KIT-VCB Series, 10kV)

  • Power substations: 10kV incoming/outgoing lines, bus tie, transformer protection
  • Industrial & mining enterprises: 10kV power distribution rooms of large factories, high voltage motors, transformers (≥1000kVA)
  • New energy power stations: 10kV photovoltaic / wind power stations, booster stations, grid connection interfaces
  • Municipal engineering: Urban power distribution networks, 10kV power distribution for industrial parks, large pump stations

7.6 Microcomputer Protection Device (KIT-PRO Series)

  • Low voltage systems: Protection for power distribution cabinets, motors, transformers and capacitors
  • High voltage systems: Protection for 10kV/35kV switchgears, transformers, lines, capacitors and reactors
  • New energy scenarios: Grid connection of photovoltaic / wind power, energy storage systems, inverter protection
  • Intelligent operation & maintenance: Remote monitoring and fault protection for data centers, industrial plants and power substations

8. Full Product Advantages

8.1 Core Functional Features

  • Safety: Full series equipped with multi-layer protection against overload, short-circuit, earth fault, phase loss, overvoltage and undervoltage. High voltage products comply with five-proof interlock standards to eliminate misoperation; low voltage products feature high insulation grade and IP20–IP40 protection grade to prevent electric shock and electric arcs.
  • Reliability: Adopts high-quality domestic and imported core components; key parts (contacts, trip units) are wear-resistant and high-temperature resistant. Mechanical life ≥5,000 operations, electrical life ≥4,000 operations. Supports wide temperature operation from -10℃ to 50℃, with moisture-proof, dust-proof, anti-aging and salt spray resistant performance for harsh industrial and outdoor environments.
  • Intelligence: High-end models integrate intelligent monitoring, communication and remote control functions, supporting MODBUS-RTU/TCP and Profinet protocols. Real-time collection of power, temperature & humidity and switch status data; automatic fault early warning, tripping and recording, with WEB/APP remote operation & maintenance to realize unattended operation.
  • Compatibility: Full series complies with national and industrial standards, compatible with mainstream brands (Schneider, ABB, Siemens). Supports single/dual mains power, mains + diesel generator and new energy grid-connected multi-source input, adaptable to AC/DC power distribution systems.
  • Easy maintenance: Modular design with simple structure for convenient disassembly and assembly. Draw-out type circuit breakers support hot plugging for maintenance and replacement without power cut. Intelligent products support remote diagnosis and program upgrade to reduce operation & maintenance costs.

8.2 Customization Advantages

  • Specification customization: Customizable rated current, voltage, breaking capacity, pole number and trip characteristics according to customer demands. High voltage products support customized parameters of 10kV/35kV; low voltage products cover full current range of 6A–1600A.
  • Function customization: Customizable intelligent monitoring, communication, remote control, harmonic governance, anti-reflux and lightning protection functions to adapt to special scenarios such as new energy grid connection and precision power distribution in harsh outdoor environments.
  • Structural customization: Customizable indoor/outdoor, wall-mounted/floor-standing/embedded cabinets of various sizes. Materials including stainless steel, cold-rolled steel plate and flame-retardant plastic are optional to match different installation spaces and environments.
  • OEM/ODM service: Supports customer brand OEM production, providing full-process customized services from design, R&D, production and testing to delivery. Customized products can be developed according to customer drawings and requirements to lower R&D and production costs for clients.

8.3 Confidentiality & Spot Supply Advantages

  • Confidentiality guarantee: Strictly implement customer information non-disclosure agreements, keeping customized schemes, drawings, parameters and customer data fully confidential to prevent information leakage. Independent R&D and production team with self-controlled core technologies, no disclosure of core processes.
  • Spot supply: Standard models (MCB, MCCB, ATS, standard power distribution cabinets) are in stock for immediate delivery with lead time ≤3 working days. Fast response for customized products, finished within 7–15 working days to meet urgent project demands.

8.4 Technical Parameter Advantages

  • High precision: Power measurement accuracy reaches 0.5S class, protection action accuracy ≤0.1s for accurate fault identification to avoid misoperation and refusal to operate.
  • Strong breaking capacity: Maximum breaking capacity of low voltage products reaches 100kA, and that of high voltage products reaches 31.5kA, capable of withstanding extreme short-circuit current to protect equipment and lines.
  • Excellent insulation performance: Insulation voltage ≥1000V (low voltage), ≥42kV (high voltage), impulse withstand voltage ≥8kV, effectively resisting humidity, dust and electromagnetic interference.
  • Wide temperature operation: Standard products operate at -5℃~40℃; customized outdoor/high temperature products support -40℃~60℃, adapting to severe conditions including frigid northern winters, high-temperature southern summers and outdoor exposure.

9. Bid Winning Control Parameters for All Products (Marked with *)

9.1 Low Voltage Miniature Circuit Breaker (KIT-MCB Series)

*1. Rated voltage AC230V/400V, supports 1P/2P/3P/4P pole types

*2. Rated current 6–63A, breaking capacity ≥6kA (standard) / ≥10kA (high breaking capacity)

*3. Trip curves C and D available, suitable for general loads and motor loads respectively

*4. Protection grade ≥IP20, insulation voltage ≥1000V

*5. Mechanical life ≥10,000 operations, electrical life ≥8,000 operations

9.2 Low Voltage Moulded Case Circuit Breaker (KIT-MCCB Series)

*1. Rated voltage AC400V/690V, rated current 100–630A

*2. Breaking capacity ≥25kA (standard) / ≥35kA (medium-high breaking capacity)

*3. Trip mode: Thermal-magnetic trip (standard) / intelligent trip (optional)

*4. Protection grade ≥IP30, with overload, short-circuit and earth fault protection

*5. Mechanical life ≥8,000 operations, electrical life ≥5,000 operations

9.3 Low Voltage Air Circuit Breaker (KIT-ACB Series)

*1. Rated voltage AC400V/690V, rated current 400–1600A

*2. Breaking capacity ≥50kA (standard) / ≥80kA (high breaking capacity)

*3. Intelligent electronic trip unit with overload, short-circuit, earth fault and phase loss protection, remotely adjustable parameters

*4. Communication functions supporting MODBUS-RTU/TCP protocols for remote monitoring and control

*5. Protection grade ≥IP40, mechanical life ≥10,000 operations

9.4 Automatic Transfer Switch (KIT-ATS Series)

*1. Rated voltage AC400V, rated current 100–1250A

*2. Switching time ≤0.5s (mains to mains), dual auto/manual modes

*3. Overvoltage / undervoltage / phase loss / undervoltage loss protection, automatic switching upon faults

*4. Pole types 3P/4P, protection grade ≥IP30

*5. Mechanical life ≥5,000 operations, equipped with fire linkage interface

9.5 High Voltage Vacuum Circuit Breaker (KIT-VCB Series, 10kV)

*1. Rated voltage 12kV, rated current 630–1600A, rated frequency 50Hz

*2. Short-circuit breaking current ≥20kA, rated short-circuit making current (peak) ≥50kA

*3. Mechanical life ≥10,000 operations, protection grade ≥IP4X

*4. Electric/manual operation modes with five-proof interlock function

*5. Insulation level: Power frequency withstand voltage (1min) ≥42kV, impulse withstand voltage ≥75kV

9.6 Microcomputer Protection Device (KIT-PRO Series)

*1. Applicable voltage AC400V/10kV/35kV, equipped with overcurrent, instantaneous overcurrent, earth fault and overvoltage protection

*2. Measurement accuracy: Current / voltage ≥0.5S class, power ≥0.5 class

*3. Standard RS485 communication interface, optional Ethernet, supports MODBUS protocol

*4. Fault recording ≥100 entries with time stamps, support remote query

*5. Power supply DC220V/AC220V, operating temperature -20℃~60℃

10. Full Product Solutions

10.1 Power Distribution Switching Solution for Civil Buildings

Pain Points

Frequent overload and short-circuit faults of lighting and socket circuits leading to hidden power safety hazards; messy distribution boxes with inconvenient maintenance; limited budget requiring cost-effective solutions.

Configuration Scheme

Basic low-end type (KIT-MCB miniature circuit breaker + KIT-IS disconnector + KIT-DB distribution box). 1P MCB for lighting, 2P MCB for sockets, main isolating switch for general power distribution. IP30 protection grade and flame-retardant shell to eliminate electric shock risks. Spot supply with convenient installation and low cost.

Application Effect

Effectively prevent fires caused by overload and short-circuit; simple structure for easy maintenance; suitable for residential buildings, apartments and villas with high cost performance.

10.2 Power Distribution Switching Solution for Industrial Plants

Pain Points

Large motor starting current causes frequent tripping; dust and humid workshop environment easily damage switches; numerous branch circuits leading to low manual inspection efficiency; balance between reliability and cost required.

Configuration Scheme

Medium-end intelligent type (KIT-MCCB moulded case circuit breaker + KIT-PM power meter + KIT-TH temperature & humidity sensor + KIT-GGD power distribution cabinet). MCCB for motor and branch circuits, thermal-magnetic trip adapting to motor startup; intelligent meters monitor power consumption, temperature & humidity sensors monitor cabinet internal environment; IP30 protection grade with dust and moisture resistance for harsh workshop environments.

Application Effect

Stable motor startup without tripping; real-time power and environmental monitoring for early fault warning; reduced manual inspection costs and improved operation & maintenance efficiency; applicable to machinery processing, electronic manufacturing, chemical and other industrial scenarios.

10.3 Power Distribution Switching Solution for Data Centers

Pain Points

Zero power interruption requirement with fast and accurate dual-circuit switching; strict stability demands for voltage and current from precision equipment; requirements for remote monitoring, energy consumption analysis and fault early warning; redundant design to ensure core load safety.

Configuration Scheme

High-end intelligent redundant type (KIT-ACB air circuit breaker + KIT-ATS dual power switch + KIT-LT precision power distribution cabinet + KIT-SC monitoring platform). Dual mains power → ATS (≤0.5s switching) → ACB → precision power distribution cabinet → servers. Intelligent trip unit with communication functions for remote monitoring of switch status, power and temperature & humidity; redundant busbar design to avoid overall power failure from single-point faults.

Application Effect

Zero power interruption to guarantee stable server operation; voltage and current fluctuation ≤±1% to adapt to precision equipment; remote visualized operation & maintenance reducing energy consumption by 15%; suitable for large and medium-sized data centers and cloud computing server rooms.

10.4 Power Distribution Switching Solution for Photovoltaic / Wind Power Stations

Pain Points

Harmonics, overvoltage and reverse current easily occur during new energy grid connection; outdoor high/low temperature and salt spray environment accelerate equipment aging; adaptation to DC/AC conversion and grid connection protection required; remote monitoring for unattended operation.

Configuration Scheme

High-end intelligent redundant type (KIT-VCB high voltage vacuum circuit breaker + KIT-PRO microcomputer protection + KIT-ACB air circuit breaker + KIT-SPD surge protection device). Photovoltaic/wind power → inverter → ACB → step-up transformer → VCB → power grid. Microcomputer protection prevents reverse current, overvoltage and governs harmonics; outdoor IP54 protection grade with salt spray resistance and anti-aging performance; remote monitoring platform for real-time grid-connected data monitoring and fault early warning.

Application Effect

Stable grid connection with harmonic content ≤5% without reverse current and overvoltage faults; stable long-term outdoor operation with service life ≥10 years; remote operation & maintenance cutting labor costs; suitable for 10kV/35kV photovoltaic power stations, wind power stations and energy storage power stations.

10.5 Power Distribution Switching Solution for 10kV Power Substations

Pain Points

Large short-circuit current in high voltage power transmission requiring strong breaking capacity; dense equipment with high safety isolation requirements; accurate protection and rapid fault cut-off required; remote monitoring for unattended operation.

Configuration Scheme

High-end intelligent redundant type (KIT-KYN28 high voltage switchgear + KIT-VCB vacuum circuit breaker + KIT-PRO microcomputer protection + KIT-CT/PT transformers). 10kV incoming line → disconnector → VCB → busbar → outgoing cabinet → loads. Five-proof interlock eliminates misoperation; microcomputer protection realizes instantaneous overcurrent/overcurrent/earth fault protection with tripping within 0.1s upon faults; remote monitoring platform for real-time high voltage equipment status tracking.

Application Effect

Stable high voltage system operation with rapid short-circuit fault isolation to protect equipment safety; five-proof interlock eliminates personal safety accidents; unattended operation improves operation & maintenance efficiency by 80%; suitable for 10kV urban substations, industrial park substations and industrial & mining enterprise substations.

11. Full Product Application Cases

11.1 Power Distribution Project of a Commercial Plaza in Guangzhou (Medium-End Intelligent Type)

Project Background

Total construction area 80,000㎡, including shopping mall, office building and hotel, requiring stable power supply for lighting, air conditioning, elevators and fire-fighting equipment.

Deployed Products

32 sets KIT-MCCB-250/3P moulded case circuit breakers, 4 sets KIT-ATS-400/4P automatic transfer switches, 8 sets KIT-GGD power distribution cabinets, 16 sets KIT-PM-96 power meters.

Application Effect

Dual power switching time ≤0.5s to ensure zero interruption of fire-fighting equipment; real-time power consumption monitoring reducing energy consumption by 12%; trouble-free operation for 3 years with convenient maintenance.

11.2 Power Distribution Project of a Cloud Computing Data Center in Shenzhen (High-End Intelligent Redundant Type)

Project Background

1,200 cabinets with core loads of servers and storage devices, requiring zero power interruption, stable voltage and remote operation & maintenance.

Deployed Products

6 sets KIT-ACB-1250/4P air circuit breakers, 3 sets KIT-ATS-630/4P automatic transfer switches, 24 sets KIT-LT-AC-1250 precision power distribution cabinets, 1 set KIT-SC-2000 monitoring platform.

Application Effect

Dual-circuit redundant power supply realizing zero power interruption; row cabinets accurately monitor energy consumption of each cabinet with real-time data upload to management platform; no faults during 2 years of system operation.

11.3 10kV Photovoltaic Power Station Power Distribution Project in Qingdao (High-End Intelligent Redundant Type)

Project Background

Installed capacity 20MW, coastal outdoor environment with high temperature, high humidity and severe salt spray corrosion, requiring stable grid connection and strong weather resistance of equipment.

Deployed Products

8 sets KIT-VCB-12/630 vacuum circuit breakers, 8 sets KIT-PRO-100 microcomputer protection devices, 6 sets KIT-KYN28-12 high voltage switchgears, 12 sets KIT-SPD-40/3P+N surge protection devices.

Application Effect

Self-adaptation of cabinet voltage and frequency to various power grid conditions; IP54 protection grade resisting salt spray corrosion with stable operation.

11.4 Power Distribution Project of an Automobile Manufacturing Plant in Dongguan (Medium-End Intelligent Type)

Project Background

Automated production lines in general assembly workshop with numerous motor loads and large startup current, requiring high power supply reliability and automation.

Deployed Products

28 sets KIT-MCCB-400/3P moulded case circuit breakers, 12 sets KIT-PM-96 power meters, 6 sets KIT-GGD power distribution cabinets, 8 sets KIT-COM-RS485 communication modules.

Application Effect

Draw-out cabinets support hot plug maintenance cutting maintenance time by 80%; automated production line control via PLC and frequency converters; no major faults during 4 years of operation with low maintenance costs.

12. Common Product Faults & Maintenance

12.1 Common Faults & Troubleshooting

12.1.1 Low Voltage Circuit Breakers (MCB/MCCB/ACB)

Fault 1: Frequent tripping
  • Causes: Overload (excessive load power), short-circuit (line/equipment short-circuit), trip unit failure, excessive ambient temperature
  • Solutions: Reduce load power, troubleshoot short-circuit faults of lines/equipment; inspect and replace faulty trip units; improve cabinet ventilation to lower ambient temperature.
Fault 2: Unable to close
  • Causes: Undervoltage / power loss, insufficient energy storage, mechanical jamming, interlock fault, unreset protection action
  • Solutions: Check power supply voltage and restore normal power supply; manually store energy and inspect energy storage mechanism; clear mechanical debris and lubricate transmission parts; inspect interlock devices to eliminate faults; reset protection devices.
Fault 3: Overheating / ablation of contacts
  • Causes: Poor contact of contacts, insufficient spring pressure, long-term overload, poor heat dissipation
  • Solutions: Polish contact surfaces to remove oxide layers; replace springs with insufficient pressure; reduce loads to avoid long-term overload; clear heat dissipation channels and improve ventilation.

12.1.2 Automatic Transfer Switch (ATS)

Fault 1: Failure of automatic switching
  • Causes: Voltage sampling fault, damaged control circuit, jammed actuator, abnormal linkage signal
  • Solutions: Inspect voltage sampling lines and sensors, replace faulty components; troubleshoot control circuits and repair damaged lines; clear debris of actuators and lubricate transmission parts; inspect fire linkage signals to restore normal state.
Fault 2: Excessively long switching time
  • Causes: Worn actuators, aging springs, improperly set control parameters
  • Solutions: Replace worn components and aging springs; reset control parameters and optimize switching logic.

12.1.3 High Voltage Vacuum Circuit Breaker (VCB)

Fault 1: Unable to close or open
  • Causes: Faulty energy storage motor, broken control circuit wire, air leakage of vacuum interrupter, mechanical interlock fault
  • Solutions: Inspect energy storage motor and power supply, replace faulty motors; troubleshoot control circuits and repair broken wires; test vacuum degree of vacuum interrupters and replace leaky ones; inspect interlock devices to eliminate faults.
Fault 2: Abnormal noise during closing/opening
  • Causes: Loose mechanical parts, insufficient lubrication, worn contacts, abnormal vacuum interrupter
  • Solutions: Fasten loose parts and add special lubricating oil; polish or replace worn contacts; test vacuum interrupters to eliminate abnormalities.

12.1.4 Microcomputer Protection Device

Fault 1: No display / failure to power on
  • Causes: Power supply fault, damaged power module, motherboard failure
  • Solutions: Inspect power supply and restore normal power supply; replace damaged power modules; repair or replace motherboards.
Fault 2: Misoperation / refusal to operate
  • Causes: Excessive sampling error, improperly set protection fixed values, faulty transformers, communication interference
  • Solutions: Calibrate sampling accuracy and replace faulty transformers; reset protection fixed values to match load demands; troubleshoot communication lines and shield interference signals.

12.2 Routine Maintenance

12.2.1 Low Voltage Switchgear (MCB/MCCB/ACB/ATS)

  • Daily inspection: Check switch status (closed/open) and normal indicator lights; observe abnormal noise, odor and overheating inside cabinets; inspect loose and overheated terminal blocks.
  • Monthly maintenance: Clean dust and debris inside cabinets to maintain good ventilation; inspect contacts for oxidation and ablation, polish mild oxidation with sandpaper; fasten terminal blocks to avoid overheating from looseness; test closing and opening functions to ensure flexible operation.
  • Quarterly maintenance: Inspect trip units, springs and transmission parts, add special lubricating oil; calibrate protection fixed values to guarantee accurate overload and short-circuit protection; test communication functions for normal remote monitoring.
  • Annual maintenance: Full disassembly and inspection, replace worn and aging components; measure insulation resistance (≥1MΩ for low voltage switches); calibrate meter accuracy to ensure precise measurement; derust and anti-corrosion treatment of cabinets to extend service life.

12.2.2 High Voltage Switchgear (VCB / Switchgears)

  • Daily inspection: Check normal indicator lights and meter display of switchgears; observe abnormal noise, odor and discharge traces; inspect SF6 gas pressure (for SF6 cabinets) and vacuum interrupter status.
  • Monthly maintenance: Clean dust and debris inside cabinets, inspect damaged and flashover traces of insulators; fasten terminal blocks to ensure good contact of contacts; test closing and opening actions with reliable mechanical interlock.
  • Quarterly maintenance: Inspect energy storage mechanisms and transmission parts for lubrication maintenance; calibrate microcomputer protection fixed values and sampling accuracy; test communication and remote control functions; inspect earthing system with earthing resistance ≤4Ω.
  • Annual maintenance: Vacuum degree test of vacuum circuit breakers, replace unqualified vacuum interrupters; detect contact wear and replace beyond tolerance; insulation withstand voltage test (power frequency withstand voltage ≥42kV for 10kV switchgears); anti-corrosion and sealing treatment of cabinets; inspect waterproof and salt spray resistance performance of outdoor cabinets.

12.2.3 Intelligent Monitoring & Communication Equipment

  • Monthly maintenance: Inspect firm wiring of sensors and communication modules without looseness or falling off; clean dust on sensor surfaces to ensure accurate monitoring; test communication signals for stable data transmission.
  • Quarterly maintenance: Calibrate sensor accuracy (temperature & humidity, power); inspect monitoring platform data with complete fault records; upgrade software programs to repair vulnerabilities.

13. Factory Strength & After-Sales Service

13.1 Factory Strength

KITOZER (Guangzhou LAIN Intelligent System Development Co., Ltd.) is a high-tech enterprise integrating R&D, production, sales and service of high & low voltage power distribution switches and intelligent power distribution equipment. The factory is located in Panyu, Guangzhou, with a 20,000㎡ modern production base, 10 automated production lines and a 5,000㎡ R&D center, employing over 300 staff, 25% of whom are R&D personnel. The core technical team has more than 15 years of deep experience in the power distribution industry with abundant R&D and production experience.

Production Capacity

Annual output of high & low voltage switchgears reaches 10,000 sets, circuit breakers 500,000 units and distribution boxes 200,000 units. Standard models are fully stocked for spot delivery, with customized products delivered rapidly at industry-leading lead times.

R&D Strength

Independent R&D of core technologies for intelligent monitoring, communication and protection, holding more than 50 patents (invention patents, utility model patents, software copyrights). The company participates in the formulation of multiple national and industrial standards with industry-leading product technical levels.

Quality Control

Strictly implement ISO9001 quality management system, ISO14001 environmental management system and ISO45001 occupational health & safety management system certifications. All raw materials adopt high-quality domestic and imported first-tier brands. Every product undergoes 100% full inspection before delivery (insulation, withstand voltage, switching operation, protection and communication tests) to guarantee stable and reliable product quality.

Qualifications & Certifications

All products pass 3C certification, type test reports and CQC certification, energy-saving certification, complying with national and industrial standards to meet bidding and project acceptance requirements across domestic industries.

13.2 After-Sales Service

Adhering to the service philosophy of “Customer First, Service Priority, Rapid Response and Full-Cycle Support”, KITOZER establishes a 7×24-hour all-weather service system to provide full-lifecycle services for customers.

Service Commitments

  1. Response time: Respond to service demands within 0.1 hours, provide remote technical support within 1 hour, on-site service for emergency projects within 6 hours (domestic), emergency supply within 12 hours.
  2. Warranty period: Full series products carry a 3-year warranty (core components 5-year warranty). Free repair and replacement of faulty parts during the warranty period, free technical support and training.
  3. Lifelong service: Provide lifelong maintenance, repair and upgrade services after warranty expiration, only charging cost fees; free technical consultation, scheme design and installation guidance permanently.

Service Content

  1. Pre-sales service: Free site survey, scheme design, product selection, technical exchange and budget quotation; provide product samples, test reports and qualification documents.
  2. In-sales service: Free installation guidance, commissioning and technical training (operation, maintenance, fault troubleshooting); assist customers with project acceptance and document filing.
  3. After-sales service: 7×24-hour technical support, remote diagnosis and fault troubleshooting; on-site maintenance, component replacement and renovation & upgrading; regular return visits, inspections and maintenance to eliminate hidden risks in advance.

Service Network

More than 20 service outlets nationwide (Guangzhou, Shenzhen, Shanghai, Beijing, Chengdu, Wuhan, Xi’an, Qingdao, etc.) covering all provinces and municipalities across China for nearby rapid service.

14. Conclusion

As core supporting equipment in the field of power distribution, the KITOZER power distribution switching system covers full scenarios including high/low voltage, civil/industrial/new energy sectors and general/critical loads, relying on core strengths such as high safety, high reliability, intelligence, easy maintenance, customizable design, spot supply and confidentiality guarantee. It delivers solid support for safe, stable and efficient operation of power systems.

Supported by strong R&D capacity, modern production base, strict quality control system and comprehensive after-sales service network, KITOZER is committed to providing customers with high-quality, cost-effective and customized power distribution switching solutions, assisting all industries in realizing intelligent, digital and safe upgrading of power distribution systems, and building a green, efficient and sustainable energy future together.

15. SEO Keywords & Tag System

15.1 Classification of Core Keywords

  • Core Main Keywords: Power Distribution Switch, KITOZER Power Distribution Switch, High & Low Voltage Power Distribution Switch, Intelligent Power Distribution Switch, Industrial Power Distribution Switch
  • High-Conversion Long-Tail Keywords: Data Center Power Distribution Switch, Photovoltaic Power Station Power Distribution Switch, 10kV High Voltage Power Distribution Switch, Low Voltage Intelligent Power Distribution Switch, ATS Automatic Transfer Switch, Precision Power Distribution Cabinet, KITOZER Circuit Breaker, Custom Power Distribution Switch
  • Industry Traffic Keywords: Power Distribution Switch Solution, Power Distribution Switch System, Power Distribution Switch Configuration List, Power Distribution Switch Technical Parameters, Power Distribution Switch Application Cases, Industrial Power Distribution Solution, Intelligent Power Distribution System
  • Brand Exclusive Keywords: KITOZER, LAIN Intelligent, KITOZER Circuit Breaker, KITOZER Power Distribution Cabinet, KITOZER High Voltage Switch, KITOZER Low Voltage Switch
  • Drop-Down & Related Search Keywords: Power Distribution Switch Brand, Power Distribution Switch Selection, Power Distribution Switch Fault Maintenance, Power Distribution Switch Manufacturer, Guangdong Power Distribution Switch, Guangzhou Power Distribution Switch, Power Distribution Switch OEM Processing, Spot Power Distribution Switch

15.2 SEO Optimization Tag System

  • Core Page Optimization Tag: Power Distribution Switch Solution _ KITOZER High & Low Voltage Intelligent Power Distribution Switch System
  • Title Tag: KITOZER Power Distribution Switch Solution_Manufacturer of High & Low Voltage Intelligent Power Distribution Switch System
  • Meta Keywords: Power Distribution Switch, KITOZER Power Distribution Switch, High & Low Voltage Power Distribution Switch, Intelligent Power Distribution Switch, Industrial Power Distribution Switch, Power Distribution Switch Solution
  • Meta Description: KITOZER (LAIN Intelligent) provides full-series high & low voltage power distribution switches and customized solutions, including low voltage miniature/moulded case/air circuit breakers, ATS automatic transfer switches, 10kV high voltage vacuum circuit breakers and intelligent power distribution cabinets. Suitable for data centers, photovoltaic power stations, industrial plants and civil buildings. Spot supply, 3-year warranty, 7×24-hour after-sales service.
  • H1 Tag: KITOZER Power Distribution Switch Solution_ High & Low Voltage Intelligent Power Distribution Switch System
  • H2 Tags: System Overview, System Composition, System Classification, System Schematic Diagrams, System Configuration List, Product Technical Parameters, Product Application Scope, Product Advantages, Bid Winning Control Parameters, Product Solutions, Application Cases, Common Product Faults & Maintenance, Factory Strength & After-Sales Service, Conclusion
  • Internal Link Optimization Tags (Anchor Text)
    1. Core Anchor Text: Power Distribution Switch, KITOZER Power Distribution Switch, High & Low Voltage Power Distribution Switch
    2. Long-Tail Anchor Text: Data Center Power Distribution Switch, Photovoltaic Power Station Power Distribution Switch, 10kV High Voltage Power Distribution Switch, Low Voltage Intelligent Power Distribution Switch
    3. Associated Anchor Text: Power Distribution Switch Solution, Intelligent Power Distribution System, Industrial Power Distribution Solution, Precision Power Distribution Cabinet
Shopping Cart