KITOZER
KITOZER

KITOZER Drawer-Type Power Distribution Cabinet System Introduction & Solution

Table of Contents

1. System Overview

KITOZER high and low voltage drawer-type power distribution cabinets are modular draw-out special power distribution equipment designed for power distribution systems (including high voltage, low voltage and new energy). Integrating traditional power distribution technology with intelligent monitoring functions, they meet the demands of power distribution, control, protection, metering and remote operation & maintenance.

The high-voltage range covers 10kV–40.5kV, while the low-voltage range covers 0.4kV. Adaptable to new energy scenarios including photovoltaic, wind power and energy storage, the products feature five-prevention interlock, hot plugging, high short-circuit withstand capacity and intelligent monitoring. Compliant with standards GB 3906, GB 7251, IEC 62271-200, they are widely deployed in industrial plants, data centers, commercial complexes, new energy power stations and substations to guarantee safe, reliable and efficient operation of power distribution systems.

KITOZER High & Low Voltage Drawer Cabinet

2. System Composition

The system consists of nine core components: high-voltage drawer distribution cabinet, low-voltage drawer distribution cabinet, special new energy power distribution unit, intelligent monitoring system, busbar system, protection devices, metering devices, operating mechanisms and cabinet structural parts. All parts adopt modular design, enabling quick plug-and-play replacement of independent functional units for easy maintenance.

  • High-voltage drawer distribution cabinet: Comprises circuit breaker trolley compartment, busbar compartment, cable compartment and secondary control compartment. Core components include vacuum circuit breaker, disconnector, earthing switch, current transformer, voltage transformer and relay protection device.
  • Low-voltage drawer distribution cabinet: Built with C-section steel combined frame, divided into horizontal busbar compartment, drawer cell and cable compartment. Core components include drawer-type circuit breaker, molded case circuit breaker, miniature circuit breaker, contactor, thermal relay and multi-function meter.
  • Special new energy power distribution unit: Includes photovoltaic grid-connected cabinet, wind power grid-connected cabinet, PCS cabinet and DC power distribution cabinet, supporting AC-DC conversion, grid-connected control and anti-islanding protection for new energy power generation.
  • Intelligent monitoring system: Composed of intelligent power meters, temperature sensors, humidity sensors, smoke detectors, communication modules (Modbus-RTU/TCP, 4G/5G) and remote monitoring platform, realizing real-time monitoring, fault early warning, remote control and data traceability.
  • Busbar system: High-voltage side adopts enclosed copper busbars; low-voltage side adopts copper busbars with high current-carrying capacity, low temperature rise and strong dynamic & thermal stability.
  • Protection devices: High-voltage side equipped with overcurrent, instantaneous overcurrent, earth fault, overvoltage and undervoltage protection plus gas protection; low-voltage side equipped with overload, short-circuit, leakage, undervoltage and phase loss protection; new energy units fitted with anti-islanding, overvoltage, undervoltage, overfrequency and underfrequency as well as DC overvoltage protection.
  • Metering devices: Consists of high-voltage metering cabinets, low-voltage multi-function energy meters and power quality monitors to realize energy metering, harmonic monitoring and power factor monitoring.
  • Operating mechanisms: High-voltage cabinets fitted with electric/manual operating mechanisms; low-voltage cabinets equipped with integrated manual-electric drawer operating mechanisms with anti-misoperation interlock functions.
  • Cabinet structural parts: Made of hot-dip galvanized steel plate / cold-rolled steel plate with electrostatic spraying, protection class IP30–IP54, featuring dustproof, moisture-proof, anti-corrosion and anti-deformation performance.

3. System Classification

Drawer Unit Operating Panel

3.1 Classification by Voltage Level

High-voltage drawer distribution cabinet (3.6kV–40.5kV)

  • KYN28-12: 10kV metal-clad withdrawable cabinet with five-prevention interlock, suitable for power distribution rooms, switching stations and industrial plants.
  • KYN61-40.5: 35kV modular cabinet with strong insulation and current-carrying capacity, matching large buildings, new energy power stations and substations.
  • XGN15-12: 10kV SF6 ring main unit with compact size and maintenance-free design, ideal for residential communities, commercial buildings and small photovoltaic power stations.

Low-voltage drawer distribution cabinet (0.4kV)

  • GCK: Draw-out type for motor control scenarios requiring frequent operation and rapid component replacement.
  • GCS: Draw-out type with modular design, excellent interchangeability and easy maintenance, applicable to industrial production lines and data centers.
  • MNS: Draw-out type with rear-mounted horizontal busbars, high space utilization and IP54 protection class, suitable for large commercial centers, data centers and energy storage power stations.

Special new energy drawer distribution cabinet

  • Photovoltaic grid-connected drawer cabinet: 0.4kV–35kV, for AC grid connection of photovoltaic power stations, equipped with anti-islanding protection and grid-connected switches.
  • Wind power grid-connected drawer cabinet: 35kV–110kV, for step-up grid connection of wind farms, featuring low voltage ride-through and fault ride-through protection.
  • Energy storage drawer cabinet: 0.4kV–35kV, for charge-discharge control of energy storage systems, with bidirectional converter and BMS interface.
  • DC drawer cabinet: DC 1000V–1500V, for photovoltaic DC convergence and energy storage DC power distribution, fitted with DC circuit breakers and fuses.

3.2 Classification by Function

Factory Production Workshop

  • Incoming cabinet: System power intake, equipped with main circuit breaker, metering device and protection device.
  • Outgoing cabinet: Distributes electric energy to various loads, fitted with drawer-type circuit breakers, contactors and protection devices.
  • Bus tie cabinet: Dual-power interconnection to improve power supply reliability, equipped with tie circuit breaker and interlock device.
  • Reactive power compensation cabinet: Reactive power compensation to boost power factor, fitted with capacitors, reactors and switching switches.
  • Metering cabinet: Dedicated energy metering, equipped with metering transformers, energy meters and sealing devices.
  • Control cabinet: Start-stop control of motors/equipment, fitted with drawer-type contactors, thermal relays, PLCs, push buttons and indicator lights.
  • Grid-connected cabinet: New energy power generation grid connection, equipped with grid-connected circuit breaker, anti-islanding protection and synchronization device.

3.3 Classification by Protection Class

  • IP30: Indoor ordinary environment, dustproof, blocking solid particles larger than 2.5mm.
  • IP40: Indoor dusty environment, dustproof, blocking solid particles larger than 1mm.
  • IP54: Indoor/outdoor harsh environment, dustproof and splash-proof, suitable for coastal, chemical and new energy power station scenarios.

4. System Schematic Diagram

Internal Wiring of Low-Voltage Drawer Cabinet

4.1 Primary Schematic of KYN28-12 High-Voltage Drawer Cabinet

  • Power intake: 10kV busbar → disconnector → vacuum circuit breaker → current transformer → cable → transformer.
  • Protection: Current transformer → relay protection device → trip coil of vacuum circuit breaker, realizing overcurrent, instantaneous overcurrent and earth fault protection.
  • Metering: Voltage transformer + current transformer → energy meter for energy measurement.

4.2 Primary Schematic of MNS Low-Voltage Drawer Cabinet

  • Power intake: Transformer low-voltage side (0.4kV) → draw-out frame circuit breaker → horizontal busbar → drawer unit → outgoing cable → load.
  • Drawer unit: Busbar → drawer-type circuit breaker → contactor → thermal relay → load, with overload, short-circuit and phase loss protection.

4.3 Schematic of Photovoltaic Grid-Connected Drawer Cabinet

  • Photovoltaic array → DC combiner box → DC distribution cabinet → inverter → grid-connected drawer cabinet (circuit breaker + anti-islanding protection) → 0.4kV busbar → load/grid.

4.4 Secondary Control Schematic of the System

  • Control power supply: AC220V/DC220V → control switch → push button → indicator light → closing/tripping coil of circuit breaker → auxiliary contact → protection device.
  • Communication: Intelligent meter → RS485 → communication module → 4G/5G → remote monitoring platform for data transmission and remote control.

5. Complete System Configuration List (Economical / Standard / Intelligent Grade)

Drawer Cabinet Assembly & Inspection

5.1 Low-Voltage Drawer Distribution Cabinet (MNS/GCS/GCK) Configuration List

Economical Grade

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1Low-Voltage Drawer CabinetMNS-0.4-1000Rated voltage AC380/400V; rated current 1000A; IP30; dimension 2200×800×1000mm; cold-rolled steel with electrostatic spraying1SetKITOZERIncludes basic frame, partition, door and lock
2Main Incoming Drawer Circuit BreakerDW45-1000/3P1000A, breaking capacity 50kA, thermal-magnetic trip, manual operation1UnitKITOZERFrame type, drawer mounted
3Outgoing Drawer Circuit BreakerCM1-250/3P250A, breaking capacity 35kA, thermal-magnetic trip, manual operation6UnitKITOZERMolded case, drawer mounted
4Busbar SystemTMY-100×10Pure copper, rated current 1250A, insulation class B1SetKITOZERHorizontal + vertical busbars
5Multi-Function MeterPD194E-9S4Measures voltage, current, power, energy; accuracy 0.5S; no communication1UnitKITOZERInstalled in incoming cabinet
6Indicator Light & Push ButtonLA39-11D/AD16-22DAC220V; red (trip), green (close), yellow (fault)10PcsKITOZERClosing/tripping indication & fault alarm
7Current TransformerLMK-0.66-300/5Ratio 300/5A, 0.5 class, rated voltage 0.66kV6UnitKITOZEROutgoing loop measurement

Standard Grade

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1Low-Voltage Drawer CabinetMNS-0.4-1600AC380/400V, 1600A, IP40; 2200×1000×1000mm; hot-dip galvanized steel spraying1SetKITOZERReinforced frame, flame retardant partition, waterproof lock
2Main Incoming Drawer Circuit BreakerDW45-1600/3P1600A, breaking capacity 65kA, electronic trip, electric+manual operation with communication port1UnitKITOZERFrame type, drawer mounted
3Outgoing Drawer Circuit BreakerNSX-400/3P400A, breaking capacity 50kA, electronic trip, electric+manual operation with communication port8UnitKITOZERMolded case, drawer mounted
4Busbar SystemTMY-120×10Tin-plated pure copper, 2000A, insulation class F, flame retardant support1SetKITOZERHorizontal & vertical busbars + insulation parts
5Intelligent Multi-Function MeterPD194E-9SYMeasures voltage, current, power, energy, harmonic; 0.2S class, Modbus-RTU, temperature monitoring1UnitKITOZERLCD display, incoming cabinet installation
6Intelligent Monitoring ModuleKTZ-M01Monitors cabinet temp, humidity, breaker status; Modbus-TCP, fault early warning1UnitKITOZERMounted on cabinet top
7Current TransformerLMK-0.66-500/5Ratio 500/5A, 0.2S class, 0.66kV, wide frequency characteristic8UnitKITOZEROutgoing loop measurement & protection
8Reactive Power Compensation CapacitorBZMJ-0.45-30-3AC450V, 30kvar, three-phase self-healing low-voltage parallel capacitor4UnitKITOZERConfigured for compensation cabinet

Intelligent Grade

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1Low-Voltage Drawer CabinetMNS-0.4-2500AC380/400V, 2500A, IP54; 2200×1200×1000mm; 304 stainless steel / galvanized steel spraying1SetKITOZERStainless steel frame, flame retardant partition, waterproof & dustproof lock, cabinet light
2Intelligent Main Incoming Drawer BreakerDW45-2500/3P2500A, breaking capacity 80kA, intelligent electronic trip, electric+manual operation, communication, fault recording & remote control1UnitKITOZERFrame type, drawer mounted with intelligent monitoring
3Intelligent Outgoing Drawer BreakerNSX-630/3P630A, breaking capacity 70kA, intelligent electronic trip, electric+manual operation, communication, leakage protection & remote control10UnitKITOZERMolded case, drawer mounted with intelligent monitoring
4Busbar SystemTMY-150×12Silver-plated pure copper, 3150A, insulation class H, flame retardant support & insulating sheath1SetKITOZERHorizontal & vertical busbars + insulation & sheath
5Intelligent Multi-Function Power MeterPD194E-9S9Monitors voltage, current, power, energy, harmonic, power factor, frequency; 0.1S class, Modbus-TCP+4G, temp/humidity/smoke detection1UnitKITOZERColor LCD, incoming cabinet installation
6Intelligent Monitoring TerminalKTZ-M02Monitors cabinet temp, humidity, smoke, water leakage, breaker & contact temperature; Modbus-TCP+5G, fault warning, remote diagnosis & data storage, touch operation1UnitKITOZERCabinet top mounting, touch screen
7Current TransformerLMK-0.66-800/5Ratio 800/5A, 0.2S class, 0.66kV, wide frequency, anti-electromagnetic interference10UnitKITOZERMeasurement, protection & metering for outgoing loops
8Active Power FilterAPF-0.4-100AAC400V, compensation current 100A, filters 2–50 harmonics, compensates reactive power & three-phase unbalance, response ≤10ms1UnitKITOZERHarmonic governance & intelligent compensation

5.2 KYN28-12 High-Voltage Drawer Distribution Cabinet Configuration List

Economical Grade

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1High-Voltage Drawer CabinetKYN28-12-125012kV, 1250A, IP30; 2300×800×1500mm; cold-rolled steel spraying, five-prevention interlock1SetKITOZERFrame, partition, door, lock & interlock included
2Vacuum Circuit Breaker TrolleyVS1-12/1250-2512kV, 1250A, short-circuit breaking capacity 25kA, mechanical life ≥10,000 times, manual operation1UnitKITOZERDraw-out trolley with vacuum interrupter
3DisconnectorGN22-12/125012kV, 1250A, dynamic & thermal stability 25kA/4s, manual operation1UnitKITOZERBusbar side isolation
4Earthing SwitchJN15-12/31.512kV, short-circuit withstand 31.5kA/2s, manual operation1UnitKITOZERCable side earthing
5Current TransformerLZZBJ9-12-600/512kV, ratio 600/5A, 0.5 class, dynamic & thermal stability 25kA/4s2UnitKITOZERMeasurement & protection
6Voltage TransformerJDZJ-1212/√3 / 0.1/√3 / 0.1/3kV, 0.5 class, three-winding three-phase1UnitKITOZERMeasurement & protection
7Relay Protection DeviceKTZ-P100Overcurrent, instantaneous overcurrent, earth fault, overvoltage, undervoltage protection; 5P10 accuracy, no communication1UnitKITOZERLocal microcomputer protection installation

Standard Grade

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1High-Voltage Drawer CabinetKYN28-12-160012kV, 1600A, IP40; 2300×1000×1500mm; hot-dip galvanized steel spraying, cabinet light, five-prevention interlock1SetKITOZERReinforced frame, flame retardant partition, waterproof lock
2Vacuum Circuit Breaker TrolleyVS1-12/1600-31.512kV, 1600A, breaking capacity 31.5kA, mechanical life ≥20,000 times, electric+manual operation with communication, solid-sealed pole, low partial discharge1UnitKITOZERDraw-out trolley
3DisconnectorGN22-12/160012kV, 1600A, dynamic & thermal stability 31.5kA/4s, electric+manual operation1UnitKITOZERBusbar side isolation
4Earthing SwitchJN15-12-4012kV, short-circuit withstand 40kA/2s, electric+manual operation1UnitKITOZERCable side earthing
5Current TransformerLZZBJ9-12-1000/512kV, ratio 1000/5A, 0.2S class, dynamic & thermal stability 31.5kA/4s, wide frequency2UnitKITOZERMeasurement, protection & metering
6Voltage TransformerJDZJ-12G12/√3 / 0.1/√3 / 0.1/3kV, 0.2S class, three-winding, ferroresonance suppression1UnitKITOZERMeasurement, protection & metering
7Microcomputer Relay Protection DeviceKTZ-P200Overcurrent, instantaneous overcurrent, earth fault, overvoltage, undervoltage, gas, differential protection; 5P20, Modbus-RTU, fault recording, LCD display1UnitKITOZERRemote communication support

Intelligent Grade

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1High-Voltage Drawer CabinetKYN28-12-250012kV, 2500A, IP54; 2300×1200×1500mm; 304 stainless steel / galvanized steel spraying, dehumidifier, intelligent access control, five-prevention interlock1SetKITOZERStainless steel frame, flame retardant partition, waterproof dustproof lock, cabinet light & dehumidifier
2Intelligent Vacuum Circuit Breaker TrolleyVS1-12/2500-4012kV, 2500A, breaking capacity 40kA, mechanical life ≥30,000 times, electric+manual operation, communication, contact temperature monitoring, fault warning & remote control, solid-sealed pole, ultra-low partial discharge ≤5pC1UnitKITOZERDraw-out trolley with intelligent monitoring
3Intelligent DisconnectorGN22-12/250012kV, 2500A, dynamic & thermal stability 40kA/4s, electric+manual operation, position monitoring & communication1UnitKITOZERBusbar side isolation with intelligent monitoring
4Intelligent Earthing SwitchJN15-12-5012kV, short-circuit withstand 50kA/2s, electric+manual operation, position monitoring & communication1UnitKITOZERCable side earthing with intelligent monitoring
5High-Precision Current TransformerLZZBJ9-12-1500/512kV, ratio 1500/5A, 0.2S class, dynamic & thermal stability 40kA/4s, wide frequency, anti-electromagnetic interference, low error2UnitKITOZERMeasurement, protection, metering & power quality monitoring
6High-Precision Voltage TransformerJDZJ-12H12/√3 / 0.1/√3 / 0.1/3kV, 0.1S class, three-winding, ferroresonance suppression, low error1UnitKITOZERMeasurement, protection, metering & power quality monitoring
7Intelligent Microcomputer Relay Protection DeviceKTZ-P300Overcurrent, instantaneous overcurrent, earth fault, overvoltage, undervoltage, gas, differential, frequency, reclosing protection; 5P20, Modbus-TCP+4G, fault recording, remote diagnosis, data storage, touch color LCD1UnitKITOZERIntelligent protection with remote operation & maintenance

6. Full Product Technical Parameters

Cabinet Wiring & Assembly Workshop

6.1 Low-Voltage Drawer Cabinet (MNS/GCS/GCK) Technical Parameters

  • Rated voltage: Main circuit AC380/400V; auxiliary circuit AC220V/DC220V
  • Rated frequency: 50Hz
  • Rated current: Horizontal busbar ≤2500A; vertical busbar ≤1000A; single drawer unit ≤630A
  • Rated short-time withstand current: 30kA/1s, 50kA/1s, 65kA/1s, 80kA/1s
  • Rated peak withstand current: 63kA, 100kA, 130kA, 176kA
  • Protection class: IP30, IP40, IP54
  • Insulation class: Class B, F, H
  • Mechanical life: Drawer unit ≥5,000 times; circuit breaker ≥10,000 times
  • Ambient temperature: -10℃~+40℃ (Economical); -20℃~+50℃ (Standard); -40℃~+70℃ (Intelligent)
  • Relative humidity: ≤90% (no condensation)

6.2 High-Voltage Drawer Cabinet (KYN28-12/KYN61-40.5) Technical Parameters

Central Control Monitoring Console

  • Rated voltage: 12kV, 24kV, 40.5kV
  • Rated frequency: 50Hz
  • Rated current: 630A, 1250A, 1600A, 2000A, 2500A, 3150A
  • Rated 4s short-time withstand current: 20kA, 25kA, 31.5kA, 40kA, 50kA
  • Rated peak withstand current: 50kA, 63kA, 80kA, 100kA, 125kA
  • Rated short-circuit breaking current: 20kA, 25kA, 31.5kA, 40kA
  • 1min power frequency withstand voltage: 42kV (12kV), 65kV (24kV), 95kV (40.5kV)
  • Lightning impulse withstand voltage (peak): 75kV (12kV), 125kV (24kV), 185kV (40.5kV)
  • Protection class: IP30, IP40, IP54
  • Mechanical life: Circuit breaker ≥10,000 times; trolley ≥5,000 times
  • Partial discharge: ≤5pC (solid-sealed pole)

6.3 Special New Energy Drawer Cabinet Technical Parameters

  • Photovoltaic grid-connected cabinet: Rated voltage 0.4kV–35kV, rated current 250A–2500A, anti-islanding response time ≤0.5s, grid synchronization accuracy ≤0.5°
  • Energy storage drawer cabinet: Rated voltage 0.4kV–35kV, rated current 500A–3150A, bidirectional converter efficiency ≥98%, charge-discharge response time ≤20ms
  • DC drawer cabinet: DC 1000V–1500V, rated current 500A–2000A, breaking capacity ≥50kA, insulation withstand voltage ≥2000V/1min

7. Product Application Scope

Data Center Power Distribution Room

7.1 Low-Voltage Drawer Cabinet Application

  • Industrial sector: Power distribution, motor & lighting control for auto manufacturing, electronics, machinery, chemical, metallurgy, textile and food processing workshops
  • Construction sector: Power distribution, fire control and emergency power supply for commercial complexes, office buildings, hotels, hospitals, schools and residential communities
  • Data center: Power supply for server rooms, cloud computing centers and communication base stations; UPS and precision air conditioner control
  • New energy sector: Low-voltage power distribution, grid-connected control and auxiliary power supply for photovoltaic stations, wind farms and energy storage stations
  • Municipal sector: Power distribution and control for municipal roads, bridges, tunnels, sewage treatment plants and water supply plants

7.2 High-Voltage Drawer Cabinet Application

  • Power system: Power distribution, control and protection for 10kV–35kV substations, switching stations and power distribution rooms
  • Industrial sector: High-voltage power distribution, motor control and transformer protection for large factories, mines, metallurgy and chemical enterprises below 35kV
  • New energy sector: Step-up station, grid-connected control and power transmission for 10kV–35kV photovoltaic stations, wind farms and energy storage stations
  • Construction sector: 10kV high-voltage power distribution and transformer power supply for large commercial complexes and super high-rise buildings

7.3 Special New Energy Drawer Cabinet Application

Outdoor New Energy Grid Cabinets

  • Photovoltaic power stations: AC grid connection, DC convergence and power distribution for centralized & distributed photovoltaic plants
  • Wind farms: Step-up grid connection, power transmission and fault protection for onshore & offshore wind farms
  • Energy storage stations: Charge-discharge control, bidirectional conversion and battery protection for grid-side, user-side and new energy matching energy storage
  • Microgrid: Power coordination, energy management and stability control for grid-connected & off-grid microgrids

8. Product Advantages

KITOZER Complete Low-Voltage Drawer Cabinet

8.1 Low-Voltage Drawer Cabinet Advantages

  1. Modular design with strong interchangeability: Standardized drawer units of the same specification can be swapped arbitrarily. Fault replacement takes less than 15 minutes, boosting maintenance efficiency by 60%.
  2. High reliability & superior dynamic/thermal stability: Adopts premium copper busbars and high-strength cabinets, with short-time withstand current up to 80kA to resist extreme short-circuit impact and ensure stable long-term operation.
  3. Safe operation with anti-misoperation interlock: Equipped with five-prevention interlock to prevent mis-closing/tripping of breakers, load disconnector switching, live earthing wire hanging, earthing wire closing and entry into live compartments.
  4. Intelligent monitoring & remote O&M: Intelligent grade integrates monitoring modules to track cabinet temperature, humidity, breaker and contact temperature in real time, supporting remote communication, fault early warning and remote control to cut O&M costs.
  5. Customized & highly adaptable: Customizable voltage grade, rated current, loop quantity, functions, cabinet size and protection class to match diverse scenarios.
  6. OEM/ODM service for cost control: Accept customized production based on customer drawings or requirements to guarantee quality and lower procurement costs.
  7. Confidential production: Sign non-disclosure agreements to protect customer technical drawings and process data from leakage.
  8. Fast delivery with stock supply: Standard models in stock for shipment within 1–3 days; customized products delivered in 15–20 working days for urgent demand.

8.2 High-Voltage Drawer Cabinet Advantages

  1. Metal-clad structure with high safety protection: Independent partition compartments block fault spread, IP54 protection class available for harsh environments.
  2. Vacuum arc extinguishing with stable performance: Core breakers use vacuum interrupters with strong arc extinguishing capacity, long service life, low noise and zero pollution; mechanical life up to 30,000 times with long-term maintenance-free operation.
  3. Solid-sealed pole with ultra-low partial discharge (Intelligent & Standard Grade): Integrated casting of vacuum interrupter and insulator, partial discharge ≤5pC, excellent insulation and safe operation.
  4. Intelligent protection with accurate fault location: Integrated microcomputer protection supports overcurrent, instantaneous overcurrent, earth fault and differential protection; rapid tripping and precise fault positioning to reduce power outage scope.
  5. Modular & flexible expansion: Cabinets can be combined freely with incoming, outgoing, tie and metering cabinets as required for easy expansion.
  6. Customized for multi-scenario use: Customizable 10kV–40.5kV voltage grades and 630A–3150A rated currents for substations, new energy stations and large industrial plants.
  7. OEM/ODM & confidentiality service: Same as low-voltage cabinets, full custom production with strict data protection.
  8. Stable stock & high on-time delivery rate: Regular models in stock; customized orders achieve over 90% on-time delivery.

8.3 Special New Energy Drawer Cabinet Advantages

  1. Strong compatibility for new energy characteristics: Specially designed for photovoltaic, wind and energy storage systems, adapting to AC-DC hybrid systems, bidirectional energy flow and intermittent power sources; equipped with anti-islanding, low voltage ride-through and fault ride-through protection.
  2. High efficiency & low loss: Adopts high-efficiency breakers, low-loss transformers and energy-saving components; system loss minimized with converter efficiency ≥98% to improve new energy utilization rate.
  3. Intelligent energy management for optimized operation: Integrated monitoring & energy management system tracks generation output, energy storage status and load demand in real time, automatically optimizing energy allocation to enhance system stability and economy.
  4. High protection for harsh environments: Anti-corrosion cabinet materials with IP54 protection class, resistant to salt spray, corrosion and aging for desert, coastal, high-temperature and high-humidity sites.

9. Bid Tender Technical Parameters (Marked with *)

9.1 Low-Voltage Drawer Cabinet Bid Parameters

    • Rated voltage: AC380/400V (main circuit), AC220V/DC220V (auxiliary circuit)
    • Rated frequency: 50Hz
    • Rated current: Horizontal busbar ≥2500A; single drawer unit ≥630A
    • Rated short-time withstand current: ≥50kA/1s (Standard Grade); ≥80kA/1s (Intelligent Grade)
    • Protection class: ≥IP40 (Standard Grade); ≥IP54 (Intelligent Grade)
    • Insulation class: ≥Class F (Standard Grade); ≥Class H (Intelligent Grade)
    • Mechanical life: Drawer unit ≥5,000 times; circuit breaker ≥10,000 times
    • Communication interface: Modbus-RTU/TCP (Standard Grade); Modbus-TCP+4G/5G (Intelligent Grade)
    • Intelligent monitoring function: Cabinet temperature, humidity, breaker & contact temperature monitoring (Intelligent Grade only)

9.2 High-Voltage Drawer Cabinet Bid Parameters

    • Rated voltage: 12kV/24kV/40.5kV
    • Rated frequency: 50Hz
    • Rated current: ≥1250A (Economical); ≥1600A (Standard); ≥2500A (Intelligent)
    • Rated 4s short-time withstand current: ≥25kA (Economical); ≥31.5kA (Standard); ≥40kA (Intelligent)
    • Rated short-circuit breaking current: ≥25kA (Economical); ≥31.5kA (Standard); ≥40kA (Intelligent)
    • 1min power frequency withstand voltage: 42kV (12kV), 65kV (24kV), 95kV (40.5kV)
    • Protection class: ≥IP40 (Standard); ≥IP54 (Intelligent)
    • Partial discharge: ≤5pC (Solid-sealed pole, Standard & Intelligent Grade)
    • Communication interface: Modbus-RTU (Standard); Modbus-TCP+4G/5G (Intelligent)
    • Intelligent protection functions: Fault recording, remote diagnosis, data storage (Intelligent Grade only)

9.3 Special New Energy Drawer Cabinet Bid Parameters

    • Rated voltage: Photovoltaic grid cabinet 0.4kV–35kV; energy storage cabinet 0.4kV–35kV; DC cabinet DC1000V–1500V
    • Anti-islanding protection response time: ≤0.5s
    • Converter efficiency: ≥98% (Energy storage cabinet)
    • Protection class: ≥IP54
    • Communication interface: Modbus-TCP+4G/5G

10. Complete Product Solutions

10.1 Power Distribution Solution for Industrial Plants

  • Demand: Multiple workshop power equipment, fluctuating loads, frequent start-stop, high power supply reliability and easy maintenance.
  • Configuration: Intelligent-grade MNS low-voltage drawer cabinet + Standard-grade KYN28-12 high-voltage drawer cabinet + reactive power compensation cabinet + active power filter
  • Solution Highlights: 10kV high-voltage incoming → transformer → low-voltage drawer cabinet for workshop power distribution; quick drawer replacement to cut power outage duration; intelligent monitoring for real-time equipment status tracking and fault early warning; reactive power compensation & harmonic governance to improve power quality and reduce energy consumption.

10.2 Power Distribution Solution for Photovoltaic Power Stations

  • Demand: Scattered photovoltaic arrays, DC convergence & inverter grid connection, anti-islanding protection, power quality governance and remote monitoring.
  • Configuration: DC drawer cabinet + Intelligent-grade photovoltaic grid-connected drawer cabinet + Intelligent-grade KYN28-12 high-voltage drawer cabinet + intelligent monitoring platform
  • Solution Highlights: PV array → DC combiner box → DC drawer cabinet → inverter → PV grid cabinet → 10kV high-voltage cabinet → public grid; grid cabinet equipped with anti-islanding protection to prevent reverse power transmission during grid blackout; monitoring platform tracks PV output, grid status and equipment temperature for remote operation & maintenance.

10.3 Power Distribution Solution for Data Centers

  • Demand: Dense loads, ultra-high power supply continuity, dual-power redundancy, precision power supply, remote monitoring and rapid fault isolation.
  • Configuration: Intelligent-grade MNS low-voltage drawer cabinet + dual-power tie cabinet + UPS distribution cabinet + intelligent monitoring terminal
  • Solution Highlights: Dual municipal power supply → high-voltage cabinet → transformer → low-voltage drawer cabinet (dual-power tie) → UPS → server loads; redundant drawer cabinet design to avoid cross-loop impact from single-circuit faults; intelligent monitoring for real-time power parameter tracking and fault early warning to guarantee 7×24h uninterrupted operation.

10.4 Power Distribution Solution for Energy Storage Power Stations

  • Demand: Battery charge-discharge control, bidirectional energy flow, overvoltage/undervoltage/overcurrent protection, BMS docking and optimized energy management.
  • Configuration: Intelligent-grade energy storage drawer cabinet + bidirectional PCS + high-voltage drawer cabinet + energy management system (EMS)
  • Solution Highlights: Battery pack → energy storage drawer cabinet → PCS → high-voltage cabinet → grid/loads; energy storage cabinet fitted with bidirectional circuit breakers and BMS interface for battery charge-discharge control & protection; EMS tracks battery status and grid demand to auto-optimize charge-discharge strategy and stabilize grid fluctuation.

11. Product Application Cases

11.1 Power Distribution Project of an Automobile Manufacturing Plant

  • Project Overview: Total investment 500 million RMB, building area 100,000㎡, including stamping, welding, coating and final assembly workshops, total load 8,000kVA.
  • Product Configuration: 6 sets KITOZER KYN28-12 high-voltage drawer cabinets, 12 sets MNS low-voltage drawer cabinets, 4 sets reactive power compensation cabinets, 2 sets active power filters.
  • Operation Effect: Stable equipment operation with rapid fault isolation cutting power outage time by 80%; interchangeable drawers lift maintenance efficiency by 60%; intelligent monitoring predicts faults in advance to reduce annual O&M cost by 30%; optimized power quality maintains power factor above 0.95 and cuts energy consumption by 15%.

11.2 10MW Distributed Photovoltaic Power Station Project

  • Project Overview: 25,000 PV modules installed over 300,000㎡ land, annual power generation 12 million kWh, connected to 10kV grid.
  • Product Configuration: 4 sets DC drawer cabinets, 8 sets photovoltaic grid-connected drawer cabinets, 3 sets KYN28-12 high-voltage drawer cabinets, 1 set intelligent monitoring platform.
  • Operation Effect: Stable grid connection with reliable anti-islanding protection (response ≤0.3s); remote monitoring platform tracks generation data to cut O&M cost by 50%; cabinets adapt to outdoor harsh environments with salt spray & corrosion resistance, annual failure rate below 0.5%.

11.3 Large-Scale Data Center Power Distribution Project

  • Project Overview: Building area 50,000㎡, 3,000 server racks, total load 12,000kVA, power supply reliability requirement 99.999%.
  • Product Configuration: 20 sets KITOZER MNS low-voltage drawer cabinets, 4 sets dual-power tie cabinets, 8 sets UPS distribution cabinets, 1 set intelligent monitoring terminal.
  • Operation Effect: Dual-power redundant supply eliminates single-point failure for 7×24h continuous operation; drawer cabinets isolate faults rapidly without overall power interruption; intelligent monitoring gives early fault alerts to eliminate hidden risks and ensure stable data center operation.

12. Common Product Faults & Maintenance Regulations

12.1 Common Faults & Troubleshooting

12.1.1 Low-Voltage Drawer Cabinet Faults

  1. Drawer fails to push/pull: Causes – jammed interlock, deformed guide rail, oxidized contact; Solutions – clean interlock, straighten rail, polish oxidized contact surface.
  2. Circuit breaker tripping: Causes – overload, short-circuit, leakage, undervoltage, faulty trip unit; Solutions – inspect loads, eliminate short-circuit points, test leakage loops, restore voltage, repair trip unit.
  3. Excess cabinet internal temperature: Causes – poor heat dissipation, overloaded busbar, poor contact at terminals; Solutions – clean heat dissipation channels, reduce load, fasten terminals, polish oxide layers.
  4. No display / communication failure of intelligent meter: Causes – power supply fault, loose communication wire, damaged meter; Solutions – check power supply, tighten communication cables, replace meter.

12.1.2 High-Voltage Drawer Cabinet Faults

  1. Circuit breaker trolley cannot rack in/out: Causes – faulty interlock, jammed track, burnt contacts; Solutions – repair interlock, clean track, polish/replace contacts.
  2. Circuit breaker fails to close/trip: Causes – faulty operating mechanism, damaged closing/tripping coil, defective control loop; Solutions – repair operating mechanism, replace coil, troubleshoot control circuit.
  3. Discharge / abnormal noise inside cabinet: Causes – aging insulation, dampness, dirt accumulation, concentrated electric field; Solutions – replace insulation parts, dehumidify, clean dirt, optimize electric field distribution.
  4. Protection device false trip / failure to trip: Causes – incorrect protection setting, faulty transformer, damaged device, wrong wiring; Solutions – verify setting value, repair transformer, replace device, troubleshoot wiring.

12.1.3 Special New Energy Drawer Cabinet Faults

  1. Grid connection failure: Causes – anti-islanding protection trigger, abnormal voltage/frequency, synchronization failure; Solutions – check grid status, adjust protection setting, repair synchronization device.
  2. Abnormal energy storage charge-discharge: Causes – faulty BMS, defective PCS, tripped circuit breaker, damaged battery pack; Solutions – re-dock BMS, repair PCS, troubleshoot breakers, test battery packs.

12.2 Maintenance Regulations

Daily Maintenance (Every Day)

  • Inspect cabinet appearance: No deformation, rust or damage; intact door locks.
  • Check indicator lights & meters: Normal display without alarm signals.
  • Monitor cabinet internal environment: Normal temperature & humidity, no abnormal odor, noise or condensation.
  • Verify communication status: Stable data upload from intelligent equipment.

Monthly Maintenance

  • Clean cabinet and internal components to remove dust and dirt.
  • Inspect drawer/trolley guide rails: No deformation or jamming, well lubricated.
  • Check contacts: No oxidation or burning, tight contact with standard pressure.
  • Inspect busbars: No deformation or overheating; fastened connecting bolts without looseness.
  • Check secondary circuits: Firm wiring without damage, good insulation.
  • Test protection devices: Reliable action and accurate setting values, normal communication.

Annual Maintenance (Full Power Cut Inspection)

  • Complete power cut maintenance with warning signs to ensure safety.
  • Disassemble drawers/trolleys to inspect internal components and replace aged/damaged parts.
  • Insulation resistance test: Low-voltage circuit ≥0.5MΩ; high-voltage circuit ≥1000MΩ, rework unqualified circuits.
  • Power frequency withstand voltage test per standards, no breakdown or flashover allowed.
  • Mechanical characteristic test: Circuit breaker closing/tripping time, speed and stroke meet specifications.
  • Earthing system inspection: Earthing resistance ≤4Ω, reliable connection without rust.

13. Factory Strength & After-Sales Service

13.1 Factory Strength

  1. Production Scale: 25,000㎡ modern production plant with sheet metal workshop, assembly workshop, testing workshop and warehouse; annual output of 10,000 high & low voltage drawer cabinets and 5,000 new energy special distribution cabinets.
  2. Equipment Capacity: Introduced German TRUMPF CNC punching machines, laser cutters, bending machines, automatic spraying lines, vacuum circuit breaker testing equipment and intelligent meter calibration devices for high automation and precision production.
  3. Technical Team: Over 50 professional technicians including 10 senior engineers, 20 electrical engineers, 10 structural engineers and 10 software engineers, with rich experience in R&D, design and manufacturing of high & low voltage power distribution equipment for customized solutions.
  4. R&D Innovation: Annual R&D investment accounts for over 5% of revenue; holds more than 20 patents (5 invention patents, 15 utility model patents) with industry-leading technology and continuous launch of intelligent, energy-saving new products.
  5. Quality Control: Strictly implements ISO9001 Quality Management System, ISO14001 Environmental Management System and ISO45001 Occupational Health & Safety Management System. Full-process quality control covers raw material procurement, production and finished product inspection, with product pass rate 99.8% and certifications including CCC, CE and type test certificates.
  6. Supply Chain Advantage: Long-term strategic cooperation with well-known component brands (Schneider, ABB, Siemens, Chint, Delixi) to guarantee component quality and controllable procurement costs.

13.2 After-Sales Service

  1. Warranty Commitment: 12-month free warranty from equipment commissioning or 18-month from factory delivery (whichever comes first). Free repair & component replacement plus full technical support within warranty period.
  2. Rapid Response: Nationwide after-sales service network with 7×24 service hotline; engineers arrive on site within 4–8 hours for urban areas and 24–48 hours for remote regions to minimize customer loss.
  3. One-Stop Full-Lifecycle Service: Pre-sales (site survey, solution design, technical consultation); In-sales (production, installation & commissioning, operation training); After-sales (maintenance, fault repair, technical upgrade).
  4. Free Technical Training: Free on-site & online training on equipment operation, maintenance and upkeep with complete technical manuals to enable independent operation by customer staff.
  5. Lifetime Maintenance: Lifetime service after warranty expires; only component cost charged, free remote diagnosis, technical support and software upgrade.
  6. Spare Parts Guarantee: Core components kept in stock for fast supply and short maintenance cycles; spare parts list provided for customers to build self-owned spare parts warehouse as required.

14. Conclusion

As core dedicated equipment for high-voltage, low-voltage and new energy power distribution systems, KITOZER high & low voltage drawer distribution cabinets feature modular design, high reliability, intelligent monitoring, superior safety protection and strong customized adaptability, fully meeting power distribution demands across industrial, construction, data center and new energy scenarios. All products comply with national and international standards and pass rigorous quality control for stable, safe, reliable and energy-efficient operation.

Our factory boasts robust R&D, production and testing capacity plus a comprehensive after-sales system to deliver one-stop power distribution solutions and full-lifecycle service support for customers. Moving forward, we will deepen layout in the power distribution sector, increase R&D investment, continuously optimize product performance and upgrade intelligence levels to help customers realize safe, reliable, efficient and intelligent power distribution system operation and contribute to high-quality development of the power industry.

15. Search Keywords, SEO & Tags

15.1 Search Keywords

High and low voltage drawer distribution cabinet, KITOZER drawer cabinet, high voltage drawer cabinet, low voltage drawer cabinet, new energy special distribution cabinet, MNS drawer cabinet, GCS drawer cabinet, GCK drawer cabinet, KYN28-12 drawer cabinet, photovoltaic grid-connected drawer cabinet, energy storage drawer cabinet, industrial power distribution solution, data center power distribution, new energy power station power distribution, intelligent drawer distribution cabinet, drawer cabinet manufacturer, customized drawer cabinet

15.2 SEO Optimization

Title optimization: Place core keywords at the front, e.g. KITOZER High & Low Voltage Drawer Distribution Cabinet – Special Power Distribution Equipment Solution for High Voltage, Low Voltage & New Energy

15.3 Tags

#HighLowVoltageDrawerCabinet #KITOZER #HighVoltageCabinet #LowVoltageCabinet #NewEnergyDistributionCabinet #MNSCabinet #GCSCabinet #KYN28-12 #PhotovoltaicGridCabinet #EnergyStorageCabinet #IndustrialPowerDistribution #DataCenterPowerDistribution #IntelligentPowerEquipment #PowerDistributionSolution

Shopping Cart