KITOZER Low-Voltage Metering Cabinet – Power Distribution System Solution

Table of Contents

1. System Overview

The KITOZER low-voltage metering cabinet is the core metering equipment for power distribution systems (including high-voltage, low-voltage and new energy systems). Designed and manufactured in accordance with GB/T 16934-2013 Electric Energy Metering Cabinets and DL/T 1745-2017 Technical Conditions for Low-Voltage Electric Energy Metering Boxes, it is applicable to 50Hz AC low-voltage power distribution networks with a rated voltage of 400V (690V) and rated current up to 4000A.

It delivers accurate electric energy metering, data monitoring, compliant settlement and anti-electricity theft management, and is widely deployed in residential communities, commercial buildings, industrial plants, data centers and new energy grid-connected scenarios. It provides core data support for electricity cost accounting, energy efficiency analysis and power grid dispatching.

Overall View of Low-Voltage Metering Cabinet

2. System Composition

The KITOZER low-voltage metering cabinet consists of five core modules: cabinet structure, core metering unit, protection & isolation unit, data acquisition & transmission unit, and safety protection unit. Each module adopts an independent design with integrated installation to guarantee precise metering, stable operation and convenient maintenance:

  • Cabinet Structure: Assembled KB profile design, made of hot-dip galvanized steel or stainless steel with an IP30~IP54 protection rating. Dustproof, waterproof and corrosion-resistant, suitable for both indoor and outdoor installation.
  • Core Metering Unit: High-precision current transformers (CT, Class 0.2S), voltage transformers (PT, Class 0.2), smart energy meters (multi-function / charge control / IoT-enabled) and dedicated metering junction boxes. It collects current and voltage signals to realize accurate electric energy measurement.
  • Protection & Isolation Unit: Disconnectors, molded case circuit breakers (MCCB), fuses and surge arresters. It provides short-circuit, overload and overvoltage protection as well as safe isolation to safeguard equipment and personnel.
  • Data Acquisition & Transmission Unit: Remote meter reading modules (HPLC/RS485/Modbus), edge computing units and communication interfaces. It supports real-time collection, storage and remote upload of electric energy, load and harmonic data, meeting the management demands of smart power grids and the Internet of Things.
  • Safety Protection Unit: Special sealing devices, anti-theft locks, live display indicators and earthing protection devices. It prevents unauthorized modification of metering loops and electricity theft while avoiding misoperation, fully complying with power supply supervision requirements.

3. System Classification

KITOZER low-voltage metering cabinets are categorized from four dimensions: application purpose, structural form, metering method and installation scenario, covering all low-voltage metering demands and supporting customized configuration.

3.1 Classification by Application Purpose

Structural Drawing of Metering Cabinet Group

  • Incoming Metering Cabinet: Installed on the incoming side of power distribution systems to measure total incoming power for settlement between power suppliers and consumers.
  • Outgoing Metering Cabinet: Mounted on the outgoing side of power distribution systems to measure power consumption of each branch circuit for internal cost accounting and load management.
  • Grid-Connected Metering Cabinet: Designed for new energy scenarios such as photovoltaic power generation and energy storage. It measures bidirectional electric energy (self-consumption and surplus power feed-in) and supports peak-valley tariff and subsidy settlement.

3.2 Classification by Structural Form

  • Fixed Metering Cabinet: Fixed installation of cabinet and components, compact structure and low cost, suitable for permanent indoor installation.
  • Withdrawable (Handcart-type) Metering Cabinet: Extractable metering units for easy maintenance and high safety, applicable to scenarios requiring ultra-high reliability.
  • Wall-mounted Metering Box: Miniaturized design with flexible installation, ideal for small-capacity scenarios including residential communities and shops.

3.3 Classification by Metering Method

Factory Production Workshop

  • Direct Connection Metering Cabinet: Adopted when load current ≤50A; the energy meter is directly connected to the circuit with simple structure and low cost.
  • Transformer-connected Metering Cabinet: Used when load current >50A. CT/PT converts large current and high voltage into standard signals to fit high-current metering scenarios.

3.4 Classification by Installation Scenario

  • Indoor Metering Cabinet: IP30 protection rating, deployed in power distribution rooms and equipment rooms.
  • Outdoor Metering Cabinet: IP54 protection rating with rainproof, dustproof and sun-proof design, suitable for outdoor substations and box-type transformers.

4. System Schematic Principle

The core working logic of the KITOZER low-voltage metering cabinet follows the flow: Signal Collection → Conversion → Metering → Transmission → Protection. CT/PT acquires current and voltage signals from the primary circuit and converts them into standard secondary signals (5A/1A current, 100V voltage) for smart energy meters to calculate power consumption. Data is uploaded to monitoring platforms via communication modules, while protection and sealing devices ensure safety and compliance.

Core Principle Breakdown:

  1. Primary circuit (400V) → Disconnector → MCCB → Class 0.2S CT → Main circuit
  2. CT secondary side (5A) & PT secondary side (100V) → Dedicated metering junction box → Smart energy meter
  3. Smart energy meter → Remote meter reading module → Local/remote monitoring platform
  4. Protection circuit: Surge arresters, fuses and earthing devices for fault protection and safe isolation
  5. Sealing devices: Cabinets, junction boxes and energy meters are sealed to prevent electricity theft and unauthorized alteration

On-site Installation of Metering Cabinets

5. Product Configuration List (3 Grades: Basic / Mid-range / High-end, Brand: KITOZER)

5.1 Basic Grade Configuration (Basic Metering Type, for Residential Communities & Small Shops)

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1Low-Voltage Metering CabinetKITOZER-JL-400-FRated voltage: 400V; Rated current: ≤630A; IP30; Hot-dip galvanized steel; Size: 800×600×2200mm1SetKITOZERFixed type, indoor use
2Current Transformer (CT)KITOZER-CT-0.2S-200/5Class 0.2S; Ratio 200/5A; Secondary current 5A; Insulation Class E; Withstand voltage 2kV/1min3PcsKITOZERThree-phase, dedicated for metering
3Smart Energy MeterKITOZER-DTSD-8623-phase 4-wire multi-function meter; Class 0.5S; 3×220/380V; 1.5(6)A; Active/reactive metering, peak-valley time-sharing, pulse output1PcsKITOZERSupport direct/transformer connection
4DisconnectorKITOZER-GL-630/3P630A, 3P, 400V; Mechanical life ≥10,000 times; Short-circuit withstand current 20kA/1s1SetKITOZERManual isolation protection
5MCCBKITOZER-M1-630/3P630A, 3P, 400V; Thermal-magnetic trip; Breaking capacity 35kA; Short-circuit & overload protection1SetKITOZERMain circuit protection
6Metering Junction BoxKITOZER-JXH-88 terminals; 500V, 5A; Flame-retardant ABS; IP201PcsKITOZERSpecial for CT/PT secondary wiring
7Live Display IndicatorKITOZER-DX-400400V; LED indication; Live alarm; Power supply AC220V1SetKITOZERHigh-voltage live monitoring
8Sealing DeviceKITOZER-FY-01Copper lead seal / electronic seal; Anti-theft tamper-proof; 5 seals per set1SetKITOZERSeal cabinet, meter and junction box
9Copper BusbarKITOZER-TP-400-630T2 copper; 40×4mm; Rated current 630A; Heat-shrink insulation; Yellow/Green/Red/Blue1SetKITOZERPrimary circuit connection
10Secondary CableKITOZER-DL-2.52.5mm² copper core; PVC insulation; 450/750V; Multi-color50MKITOZERSecondary circuit wiring

5.2 Mid-range Configuration (Smart Metering Type, for Commercial Buildings & Medium-sized Factories)

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1Low-Voltage Metering CabinetKITOZER-JL-400-Z400V; ≤1600A; IP40; Sprayed cold-rolled steel; 1000×800×2200mm1SetKITOZERFixed type, indoor/outdoor optional
2CTKITOZER-CT-0.2S-600/5Class 0.2S; 600/5A; 5A secondary; Class B insulation; 3kV/1min withstand voltage; Error ≤±0.2%3PcsKITOZERThree-phase high-precision metering
3PTKITOZER-PT-0.2-400/100Class 0.2; 400/100V; 100V secondary; Class B insulation; 3kV/1min withstand voltage; Error ≤±0.2%3PcsKITOZERThree-phase metering dedicated
4Charge Control Smart Energy MeterKITOZER-DTSD-9623-phase 4-wire charge control meter; Class 0.2S; 3×220/380V; 1.5(6)A; Peak-valley, remote recharge, remote switching, harmonic monitoring1PcsKITOZERSupport charge control & remote operation
5Withdrawable DisconnectorKITOZER-GL-1600/3P-C1600A, 3P, 400V; Mechanical life ≥15,000 times; 40kA/1s short-circuit withstand; withdrawable design1SetKITOZEREasy maintenance isolation
6MCCBKITOZER-M2-1600/3P1600A, 3P, 400V; Electronic trip; Breaking capacity 50kA; Short-circuit, overload & leakage protection1SetKITOZERAdvanced main circuit protection
7Remote Meter Reading ModuleKITOZER-CM-HPLCHPLC power line carrier; DL/T 645-2007; Transmission distance ≥500m; AC220V power supply; Upload cycle adjustable1SetKITOZERRemote data transmission
8Dedicated Secondary Surge ArresterKITOZER-LY-400/20400V; Nominal discharge current 20kA; Max discharge current 40kA; Protection level ≤1.5kV; Response time ≤25ns1SetKITOZERSecondary circuit lightning protection
9Multi-function MeterKITOZER-YB-300Measure voltage, current, power, power factor, frequency, harmonic; Class 0.5; LCD display; RS485/Modbus-RTU1PcsKITOZERReal-time electrical parameter monitoring
10Earthing Protection DeviceKITOZER-JD-01Copper material; Earthing resistance ≤4Ω; Rated current 1600A; Comply with GB 501491SetKITOZERSafety earthing for equipment & cabinet
11Sealing DeviceKITOZER-FY-02Electronic seal; Stainless steel; Anti-theft, remote tamper alarm; 6 seals per set1SetKITOZERIntelligent anti-electricity theft
12Copper BusbarKITOZER-TP-400-1600T2 copper; 60×6mm; Rated current 1600A; Heat-shrink insulation1SetKITOZERPrimary circuit connection
13Secondary CableKITOZER-DL-4.04.0mm² copper core; PVC insulation; 450/750V; Multi-color80MKITOZERSecondary circuit wiring

5.3 High-end Configuration (IoT Smart Type, for Data Centers, New Energy Grid Connection & Large-scale Industry)

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1Low-Voltage Metering CabinetKITOZER-JL-400-G400V (690V optional); ≤4000A; IP54; 304 stainless steel; 1200×1000×2200mm; Rain/dust/corrosion resistant1SetKITOZERWithdrawable, outdoor/humid environment
2High-precision CTKITOZER-CT-0.2S-2000/5Class 0.2S (0.1S optional); 2000/5A; 5A secondary; Class F insulation; 5kV/1min withstand voltage; Error ≤±0.15%; Shielded anti-interference3PcsKITOZERThree-phase ultra-precision metering
3High-precision PTKITOZER-PT-0.2-690/100Class 0.2 (0.1 optional); 690/100V; 100V secondary; Class F insulation; 5kV/1min withstand voltage; Error ≤±0.15%; Shielded anti-interference3PcsKITOZERThree-phase ultra-precision metering
4IoT Smart Energy MeterKITOZER-DTSD-9823-phase 4-wire IoT meter; Class 0.2S; 3×220/380V (690V optional); 1.5(6)A; Bidirectional metering, harmonic analysis, load forecasting, edge computing, 5G/4G, blockchain data storage1PcsKITOZERSpecial for new energy grid connection
5Handcart DisconnectorKITOZER-GL-4000/3P-S4000A, 3P, 690V; Mechanical life ≥20,000 times; 63kA/1s short-circuit withstand; Interlock withdrawable design1SetKITOZERHigh-current isolation with safety interlock
6Intelligent MCCBKITOZER-M3-4000/3P4000A, 3P, 690V; Intelligent electronic trip; Breaking capacity 80kA; Short-circuit, overload, leakage, ground fault & arc fault protection, communication port equipped1SetKITOZERAdvanced fault monitoring & protection
75G/4G Communication ModuleKITOZER-CM-5G5G/4G full network, HPLC, RS485, Modbus-TCP; DL/T 645, MQTT, IEC 62056; Speed ≥100Mbps; AC220V; Edge computing & data encryption1SetKITOZERHigh-speed IoT remote transmission
8Edge Computing UnitKITOZER-EC-1004-core 1.5GHz processor; Computing power ≥4 TOPS; 8GB RAM + 64GB ROM; Linux OS; Data analysis, fault early warning, load identification, local control, AI algorithm support1SetKITOZERIntelligent data processing & prediction
9Secondary Surge ArresterKITOZER-LY-690/40690V; Nominal discharge current 40kA; Max discharge current 80kA; Protection level ≤1.0kV; Response time ≤20ns; Remote alarm contact1SetKITOZERAdvanced secondary lightning protection
10Multi-function Power AnalyzerKITOZER-FX-500Monitor voltage, current, power, power factor, frequency, 2~50th harmonic, three-phase unbalance, flicker; Class 0.2; Color LCD; RS485/Ethernet/Modbus-TCP; Data storage & export1PcsKITOZERComprehensive power quality monitoring
11Intelligent Earthing Protection SystemKITOZER-JD-02Earthing resistance ≤1Ω; Rated current 4000A; Real-time resistance monitoring & fault alarm; Comply with GB 50149 & IEC 610081SetKITOZERPremium safety earthing solution
12Electronic Seal & Anti-theft SystemKITOZER-FY-03Smart electronic seal + monitoring camera; Stainless steel; Tamper alarm, video evidence, blockchain traceability; 8 seals + 1 camera per set1SetKITOZERTraceable intelligent anti-theft solution
13High-strength Copper BusbarKITOZER-TP-690-4000T2 tinned copper; 100×10mm; Rated current 4000A; High-temperature heat-shrink insulation; Anti-oxidation tin plating1SetKITOZERHigh-current primary circuit connection
14High-temperature Secondary CableKITOZER-DL-6.06.0mm² tinned copper core; 105℃ high-temperature PVC insulation; 450/750V; Multi-color; Anti-aging & heat resistant100MKITOZERHigh-temperature environment wiring

6. Full Series Technical Specifications

6.1 Low-Voltage Metering Cabinet (KITOZER-JL Series)

Internal Wiring Drawing of Metering Cabinet

  • Rated Voltage: 400V (Basic/Mid-range), 400V/690V (High-end)
  • Rated Current: ≤630A (Basic), ≤1600A (Mid-range), ≤4000A (High-end)
  • Protection Rating: IP30 (Basic), IP40 (Mid-range), IP54 (High-end)
  • Cabinet Material: Hot-dip galvanized steel (Basic), Sprayed cold-rolled steel (Mid-range), 304 stainless steel (High-end)
  • Dimension (L×D×H): 800×600×2200mm (Basic), 1000×800×2200mm (Mid-range), 1200×1000×2200mm (High-end)
  • Structure: Fixed (Basic/Mid-range), Withdrawable/Handcart (High-end)
  • Operating Environment: -5℃ ~ 40℃, Relative Humidity ≤85% (No condensation), Altitude ≤2000m

6.2 Current Transformer (CT, KITOZER-CT Series)

  • Accuracy Class: 0.2S (Basic/Mid-range), 0.2S/0.1S optional (High-end)
  • Current Ratio: 200/5A (Basic), 600/5A (Mid-range), 2000/5A (High-end)
  • Secondary Rated Current: 5A
  • Insulation Class: Class E (Basic), Class B (Mid-range), Class F (High-end)
  • Withstand Voltage: 2kV/1min (Basic), 3kV/1min (Mid-range), 5kV/1min (High-end)
  • Allowable Error: ≤±0.2% (Basic/Mid-range), ≤±0.15% (High-end)
  • Anti-interference: Standard insulation (Basic/Mid-range), Shielded anti-electromagnetic interference (High-end)

6.3 Voltage Transformer (PT, KITOZER-PT Series)

  • Accuracy Class: 0.2 (Mid-range/High-end)
  • Voltage Ratio: 400/100V (Mid-range), 690/100V (High-end)
  • Secondary Rated Voltage: 100V
  • Insulation Class: Class B (Mid-range), Class F (High-end)
  • Withstand Voltage: 3kV/1min (Mid-range), 5kV/1min (High-end)
  • Allowable Error: ≤±0.2% (Mid-range), ≤±0.15% (High-end)
  • Anti-interference: Standard insulation (Mid-range), Shielded anti-electromagnetic interference (High-end)

6.4 Smart Energy Meter (KITOZER-DTSD Series)

Finished Metering Cabinet Workshop

  • Type: 3-phase 4-wire multi-function (Basic), Charge control smart meter (Mid-range), IoT smart meter (High-end)
  • Accuracy Class: 0.5S (Basic), 0.2S (Mid-range/High-end)
  • Rated Voltage: 3×220/380V (Basic/Mid-range), 3×220/380V/690V (High-end)
  • Rated Current: 1.5(6)A (transformer connection), 5(60)A (direct connection)
  • Core Functions
    • Basic: Active/reactive energy metering, peak-valley time-sharing, pulse output
    • Mid-range: Add remote recharge, remote switching, harmonic monitoring
    • High-end: Add bidirectional metering, load forecasting, edge computing, 5G communication, blockchain data storage
  • Communication Port: Pulse output (Basic), RS485/HPLC (Mid-range), 5G/4G/Ethernet/Modbus-TCP (High-end)

6.5 Disconnector (KITOZER-GL Series)

  • Rated Current: 630A (Basic), 1600A (Mid-range), 4000A (High-end)
  • Poles: 3P
  • Rated Voltage: 400V (Basic/Mid-range), 690V (High-end)
  • Mechanical Life: ≥10,000 times (Basic), ≥15,000 times (Mid-range), ≥20,000 times (High-end)
  • Short-circuit Withstand Current: 20kA/1s (Basic), 40kA/1s (Mid-range), 63kA/1s (High-end)
  • Operation Mode: Manual (Basic/Mid-range), Manual + Electric (High-end)

6.6 MCCB (KITOZER-M Series)

Smart Power Monitoring Platform

  • Rated Current: 630A (Basic), 1600A (Mid-range), 4000A (High-end)
  • Poles: 3P
  • Rated Voltage: 400V (Basic/Mid-range), 690V (High-end)
  • Trip Unit: Thermal-magnetic (Basic), Electronic (Mid-range), Intelligent Electronic (High-end)
  • Breaking Capacity: 35kA (Basic), 50kA (Mid-range), 80kA (High-end)
  • Protection Functions
    • Basic: Short-circuit & overload protection
    • Mid-range: Add leakage protection
    • High-end: Add ground fault, arc fault & intelligent monitoring

6.7 Communication Module (KITOZER-CM Series)

  • Communication Mode
    • Basic: No built-in module, only pulse output
    • Mid-range: HPLC power line carrier, RS485
    • High-end: 5G/4G full network, HPLC, RS485, Ethernet, Modbus-TCP
  • Transmission Speed: ≥9600bps (Mid-range), ≥100Mbps (High-end)
  • Communication Protocol: DL/T 645-2007 (Mid-range), DL/T 645 + MQTT + IEC 62056 (High-end)
  • Power Supply: AC220V±10%
  • Data Encryption: None (Mid-range), National Cryptography Algorithm Encryption (High-end)

6.8 Edge Computing Unit (KITOZER-EC-100, High-end Exclusive)

  • Processor: 4-core 1.5GHz
  • Computing Power: ≥4 TOPS
  • Storage: 8GB RAM + 64GB ROM
  • OS: Linux
  • Core Functions: Data collection, analysis, storage, fault early warning, load identification, local control, AI algorithm support

6.9 Surge Arrester (KITOZER-LY Series)

On-site Wiring Maintenance

  • Rated Voltage: 400V (Basic/Mid-range), 690V (High-end)
  • Nominal Discharge Current: 20kA (Mid-range), 40kA (High-end)
  • Max Discharge Current: 40kA (Mid-range), 80kA (High-end)
  • Voltage Protection Level: ≤1.5kV (Mid-range), ≤1.0kV (High-end)
  • Response Time: ≤25ns (Mid-range), ≤20ns (High-end)

6.10 Multi-function Meter / Power Analyzer (KITOZER-YB/FX Series)

  • Measurable Parameters
    • Basic: Not equipped
    • Mid-range: Voltage, current, power, power factor, frequency, 2~21st harmonic
    • High-end: Add three-phase unbalance, flicker, 2~50th harmonic, event recording
  • Accuracy Class: 0.5 (Mid-range), 0.2 (High-end)
  • Display: LCD (Mid-range), Color LCD (High-end)
  • Communication Port: RS485/Modbus-RTU (Mid-range), RS485/Ethernet/Modbus-TCP (High-end)

7. Application Scope of Full Series Products

Outdoor Installed Metering Cabinet

7.1 Low-Voltage Metering Cabinet

  • Basic Grade: Residential communities, small shops, township enterprises, rural power distribution stations with low capacity and budget constraints
  • Mid-range Grade: Commercial complexes, office buildings, medium-sized factories, schools, hospitals and industrial parks requiring medium capacity and intelligent metering
  • High-end Grade: Data centers, new energy power stations (PV/Energy storage/Wind power), large industrial plants, rail transit, airports and ports with high capacity, ultra-high reliability and IoT bidirectional metering demands

7.2 CT & PT

Compatible with all KITOZER low-voltage metering cabinets to collect high-precision current and voltage signals for 400V~690V low-voltage distribution networks. Cover all residential, commercial, industrial and new energy scenarios, especially high-current high-precision metering for data centers and grid-connected new energy stations.

7.3 Smart Energy Meter

  • Multi-function Meter (Basic): Basic electricity settlement for residential communities and small shops
  • Charge Control Smart Meter (Mid-range): Commercial buildings and medium factories requiring remote recharge, load control and energy efficiency management
  • IoT Smart Meter (High-end): PV/energy storage grid connection, data centers and large industrial plants needing bidirectional metering, harmonic analysis, edge computing and remote monitoring, supporting peak-valley tariff and subsidy settlement with blockchain data storage

7.4 Disconnector & MCCB

Core isolation and protection devices for all KITOZER metering cabinets, applicable to 400V~690V distribution networks across all scenarios. Deliver short-circuit, overload, leakage and ground fault protection to protect equipment and personnel safety.

7.5 Communication Module & Edge Computing Unit

  • HPLC/RS485 Module (Mid-range): Commercial buildings and medium factories for remote meter reading and local monitoring system integration
  • 5G/4G & Edge Computing Unit (High-end): Data centers and new energy stations requiring high-speed data transmission, intelligent analysis, fault prediction and intelligent operation & maintenance

7.6 Surge Arrester & Earthing Protection Device

Suitable for all indoor and outdoor low-voltage distribution scenarios, especially thunderstorm-prone areas, outdoor box transformers and new energy stations. Provide primary/secondary lightning protection and reliable earthing to ensure stable equipment operation under harsh conditions.

7.7 Sealing & Anti-theft System

Applicable to all metering scenarios requiring regulatory anti-theft control, including residential, commercial, industrial and new energy projects. Prevent unauthorized tampering of metering loops and guarantee impartial metering data to fully comply with power grid supervision standards.

8. Product Advantages

8.1 General Core Advantages for All Series

  1. Ultra-precise Metering: Adopt Class 0.2S CT/PT and Class 0.2S smart meters, with metering error ≤±0.2% (≤±0.15% for high-end), far exceeding national standards to eliminate electricity settlement disputes.
  2. Fully Compliant Design: Strictly designed per GB/T 16934-2013, DL/T 1745-2017 and State Grid Q/GDW 11008-2013. Independent, sealable metering loops pass all power supply authority acceptance tests with 100% compliance.
  3. High Reliability: Premium steel cabinets with IP30~IP54 dust/water/corrosion resistance. All core components pass strict factory testing with MTBF ≥80,000 hours.
  4. Full Customization: Customizable dimensions, parameters and functions for unique site requirements; OEM & ODM manufacturing available with non-disclosure agreements to protect client technical data.
  5. Fast Delivery: Standard models in stock for shipment within 72 hours; customized products delivered within 15 days.
  6. Confidentiality Guarantee: Sign formal NDAs to protect client drawings, parameters and project schemes against information leakage.

8.2 Grade-specific Advantages

8.2.1 Basic Grade (Basic Metering)

  • Cost-effective simplified configuration to meet basic metering demands for budget-limited projects
  • Compact size and light weight for flexible installation in narrow spaces such as residential corridors and shop corners
  • Simple manual operation with low professional maintenance requirements and reduced operation costs

8.2.2 Mid-range Grade (Smart Metering)

  • Upgraded intelligent functions including remote meter reading, charge control and harmonic monitoring to cut manual operation costs and support smart grid energy efficiency management
  • IP40 sprayed steel cabinet with enhanced anti-corrosion and anti-rust performance for extended service life
  • Withdrawable disconnector for safe offline maintenance and shorter power outage duration

8.2.3 High-end Grade (IoT Smart Metering)

  1. Bidirectional Energy Measurement: Support PV/energy storage self-consumption and surplus power feed-in to accurately calculate electricity bills and government subsidies.
  2. Full IoT Capability: Integrate 5G/4G communication, edge computing and AI algorithms for high-speed data transmission, intelligent fault early warning and load forecasting, compatible with industrial IoT operation platforms.
  3. Harsh Environment Adaptability: 304 stainless steel cabinet with IP54 rating for rain, dust, UV and corrosion resistance, suitable for outdoor and high-humidity sites; redundant core components support 24/7 continuous operation.
  4. Advanced Safety Protection: Integrated smart electronic seals, video monitoring and blockchain traceability to prevent electricity theft and tampering; intelligent earthing system monitors grounding resistance in real time and triggers automatic fault alarms.

8.3 General Technical Strengths

  • Wide voltage compatibility: Cover 400V~690V to fit all mainstream low-voltage distribution networks
  • Wide operating temperature range: -5℃ ~ 40℃, adapting to hot southern and cold northern climate zones
  • Strong anti-electromagnetic interference: High-end CT/PT with shielding layers and shielded secondary cables to eliminate signal distortion
  • Long service life: Cabinet service life ≥20 years, core components ≥10 years, lowering total lifecycle costs

9. Tender Control Parameters (★ Marked Mandatory Indicators)

9.1 Low-Voltage Metering Cabinet

  • ★ Rated Voltage: 400V (Basic/Mid-range), 400V/690V (High-end)
  • ★ Rated Current: ≤630A (Basic), ≤1600A (Mid-range), ≤4000A (High-end)
  • ★ Protection Rating: IP30 (Basic), IP40 (Mid-range), IP54 (High-end)
  • ★ Cabinet Material: Hot-dip galvanized steel (Basic), Sprayed cold-rolled steel (Mid-range), 304 stainless steel (High-end)
  • ★ Structure: Fixed (Basic/Mid-range), Withdrawable/Handcart (High-end)
  • ★ Operating Temperature: -5℃ ~ 40℃

9.2 Current Transformer (CT)

  • ★ Accuracy Class: 0.2S (Basic/Mid-range), 0.2S/0.1S optional (High-end)
  • ★ Current Ratio: 200/5A (Basic), 600/5A (Mid-range), 2000/5A (High-end)
  • ★ Secondary Rated Current: 5A
  • ★ Withstand Voltage: 2kV/1min (Basic), 3kV/1min (Mid-range), 5kV/1min (High-end)
  • ★ Allowable Error: ≤±0.2% (Basic/Mid-range), ≤±0.15% (High-end)

9.3 Voltage Transformer (PT)

  • ★ Accuracy Class: 0.2 (Mid-range/High-end)
  • ★ Voltage Ratio: 400/100V (Mid-range), 690/100V (High-end)
  • ★ Secondary Rated Voltage: 100V
  • ★ Withstand Voltage: 3kV/1min (Mid-range), 5kV/1min (High-end)
  • ★ Allowable Error: ≤±0.2% (Mid-range), ≤±0.15% (High-end)

9.4 Smart Energy Meter

  • ★ Accuracy Class: 0.5S (Basic), 0.2S (Mid-range/High-end)
  • ★ Rated Voltage: 3×220/380V (Basic/Mid-range), 3×220/380V/690V (High-end)
  • ★ Communication Port: Pulse output (Basic), RS485/HPLC (Mid-range), 5G/4G/Ethernet (High-end)
  • ★ Bidirectional Metering Function: Exclusive for high-end new energy grid connection
  • ★ Harmonic Monitoring: Mid-range supports 2~21st harmonic; High-end supports 2~50th harmonic

9.5 Disconnector

  • ★ Rated Current: 630A (Basic), 1600A (Mid-range), 4000A (High-end)
  • ★ Rated Voltage: 400V (Basic/Mid-range), 690V (High-end)
  • ★ Short-circuit Withstand Current: 20kA/1s (Basic), 40kA/1s (Mid-range), 63kA/1s (High-end)
  • ★ Mechanical Life: ≥10,000 times (Basic), ≥15,000 times (Mid-range), ≥20,000 times (High-end)

9.6 MCCB

  • ★ Rated Current: 630A (Basic), 1600A (Mid-range), 4000A (High-end)
  • ★ Rated Voltage: 400V (Basic/Mid-range), 690V (High-end)
  • ★ Breaking Capacity: 35kA (Basic), 50kA (Mid-range), 80kA (High-end)
  • ★ Protection Functions: Short-circuit + Overload (Basic); Short-circuit + Overload + Leakage (Mid-range); Short-circuit + Overload + Leakage + Ground Fault + Arc Fault (High-end)

9.7 Communication Module

  • ★ Communication Mode: HPLC/RS485 (Mid-range), 5G/4G/Ethernet (High-end)
  • ★ Communication Protocol: DL/T 645-2007 (Mid-range), DL/T 645 + MQTT + IEC 62056 (High-end)
  • ★ Data Encryption: National Cryptography Algorithm (High-end exclusive)

9.8 Surge Arrester

  • ★ Rated Voltage: 400V (Mid-range), 690V (High-end)
  • ★ Nominal Discharge Current: 20kA (Mid-range), 40kA (High-end)
  • ★ Protection Level: ≤1.5kV (Mid-range), ≤1.0kV (High-end)

9.9 Edge Computing Unit (High-end Exclusive)

  • ★ Computing Power: ≥4 TOPS
  • ★ Storage Capacity: 8GB RAM + 64GB ROM
  • ★ AI Algorithm Support: Fault early warning & load identification

10. Full Scenario System Solutions

10.1 Low-Voltage Metering Solution for Residential Communities (Basic Grade)

Pain Points: Large household quantity, scattered load, limited budget, anti-theft demand and regulatory settlement compliance

Configuration: KITOZER-JL-400-F metering cabinet + Class 0.2S CT + Class 0.5S multi-function energy meter + disconnector + MCCB + sealing device

Solution Strengths: Low cost, flexible installation and simple maintenance; High-precision metering fully meeting power grid standards; Sealing system eliminates electricity theft and billing disputes

Operation Effect: Realize accurate household energy measurement and automatic billing; Manual meter reading cost reduced by 60%; 90% drop in electricity theft incidents with 100% regulatory compliance

10.2 Low-Voltage Metering Solution for Commercial Buildings (Mid-range Grade)

Pain Points: Fluctuating load, peak-valley tariff requirement, remote meter reading, energy efficiency management and anti-theft control

Configuration: KITOZER-JL-400-Z metering cabinet + Class 0.2S CT/PT + Class 0.2S charge control meter + withdrawable disconnector + intelligent MCCB + HPLC remote module + multi-function meter + electronic seal

Solution Strengths: High intelligence for remote recharge, peak-valley billing and harmonic monitoring to optimize power quality; Withdrawable design cuts maintenance downtime; Traceable electronic seals prevent theft

Operation Effect: 100% remote meter reading coverage with 80% lower manual operation cost; Billing efficiency improved 5 times; Harmonic pollution reduced by 30% for stable electrical equipment operation

10.3 Low-Voltage Metering Solution for Data Centers (High-end Grade)

Pain Points: Ultra-large load, extreme stability demand, bidirectional metering for energy storage backup, full power quality monitoring, remote intelligent operation & maintenance, high environmental protection rating

Configuration: KITOZER-JL-400-G metering cabinet + high-precision Class 0.2S CT/PT + IoT bidirectional energy meter + handcart disconnector + intelligent MCCB + 5G communication module + edge computing unit + power quality analyzer + intelligent earthing & anti-theft system

Solution Strengths: IP54 high protection rating for high-dust/humid data center environments; Ultra-precise bidirectional metering for energy storage power settlement; 5G IoT and edge computing deliver 72-hour advance fault warning; Full power quality monitoring safeguards critical IT equipment; Blockchain traceable anti-theft system

Operation Effect: Accurate bidirectional measurement without billing disputes; Equipment failure rate reduced by 50% via early warning; On-site inspection frequency cut by 54% and operation cost down 70%; Data center PUE optimized below 1.5 with 25% energy efficiency improvement

10.4 New Energy Grid-connected Metering Solution (High-end Grade)

Pain Points: Bidirectional power flow (PV/energy storage self-consumption & surplus feed-in), peak-valley subsidy settlement, remote monitoring, anti-theft and harsh outdoor environment

Configuration: Same high-end data center solution, optimized for bidirectional metering, 5G transmission, edge computing and intelligent anti-theft functions

Solution Strengths: Accurate bidirectional measurement to maximize user revenue under peak-valley tariff policies; Real-time remote generation & consumption monitoring; Edge computing for power generation prediction; Blockchain data storage eliminates subsidy settlement disputes

Operation Effect: 15%~20% increase in user annual revenue via optimized tariff settlement; 100% remote monitoring coverage with 70% lower maintenance cost; 95% reduction in subsidy disputes and full regulatory compliance

11. Project Application Cases

11.1 Residential Community Project in Guangzhou (Basic Grade)

Project Overview: 5 buildings with 300 households, 400V low-voltage distribution, requiring household accurate metering and anti-theft control

Configuration: 12 sets KITOZER-JL-400-F cabinets, 36 pcs Class 0.2S CT, 300 pcs multi-function energy meters, 12 disconnectors, 12 MCCBs, 12 sealing kits

Project Outcome: Put into operation in June 2023 with zero operational faults; Metering error ≤±0.2% with zero billing disputes; No electricity theft incidents; 60% reduction in manual meter reading cost, highly recognized by property management and residents

11.2 Commercial Complex Project in Shenzhen (Mid-range Grade)

Project Overview: 8-floor shopping mall covering 50,000 ㎡, 400V distribution, requiring split metering for each floor and tenant, peak-valley billing and energy efficiency monitoring

Configuration: 8 sets KITOZER-JL-400-Z cabinets, 24 pcs Class 0.2S CT/PT, 200 pcs charge control meters, 8 withdrawable disconnectors, 8 intelligent MCCBs, 8 HPLC remote modules, 8 multi-function meters, 8 electronic seal kits

Project Outcome: Launched in January 2024 with stable operation; 100% remote meter reading coverage and 80% lower labor cost; Peak-valley billing cuts tenant electricity expense by 12%; Harmonic governance reduces equipment failure rate by 30%, well-received by mall management and merchants

11.3 Data Center Project in Dongguan (High-end Grade)

Project Overview: 20,000 ㎡ data center with 2,000 server racks, 400V/690V distribution with energy storage backup, demanding bidirectional metering, power quality monitoring and high environmental protection

Configuration: 12 sets KITOZER-JL-400-G cabinets, 36 pcs high-precision CT/PT, 12 IoT energy meters, 12 handcart disconnectors, 12 intelligent MCCBs, 12 sets 5G communication modules, edge computing units, power analyzers, intelligent earthing and anti-theft systems

Project Outcome: Commissioned in August 2024 with stable zero-fault operation; Bidirectional metering error ≤±0.15% with no energy storage billing disputes; 72-hour advance fault warning reduces equipment failure rate by 50%; 54% fewer on-site inspections and 70% lower operation cost; PUE optimized to 1.48 with 28% energy efficiency improvement, reaching leading domestic standards

11.4 5MW PV Grid-connected Station in Foshan (High-end Grade)

Project Overview: 5MW photovoltaic power station with 400V low-voltage grid connection, requiring bidirectional metering, peak-valley subsidy settlement, remote monitoring and anti-theft control

Configuration: 2 sets KITOZER-JL-400-G high-end cabinets with full suite high-precision CT/PT, IoT energy meters, 5G communication modules, edge computing units and intelligent anti-theft systems

Project Outcome: Put into service in May 2024 with stable operation; Zero measurement error for self-consumption and surplus feed-in power; 18% higher annual user revenue via peak-valley tariff; 100% remote monitoring coverage cutting maintenance cost by 70%; Blockchain data storage eliminates all subsidy disputes, approved by power grid companies and end users

12. Product Fault Troubleshooting & Maintenance Guidelines

12.1 Common Faults & Solutions

12.1.1 Excessive Metering Error

  • Causes: Low-precision CT/PT, loose secondary wiring, faulty energy meter, strong electromagnetic interference
  • Solutions: Replace Class 0.2S high-precision transformers; Tighten all secondary terminals; Calibrate or replace faulty meters; Deploy shielded secondary cables and isolate from high-power electromagnetic equipment

12.1.2 Remote Meter Reading Failure

  • Causes: Damaged communication module, weak signal, mismatched communication protocol, power supply failure
  • Solutions: Inspect module indicator lights and replace faulty units; Adjust antenna position to boost signal strength; Verify protocol matching with central monitoring platform; Check power wiring and restore power supply

12.1.3 MCCB Tripping

  • Causes: Circuit short-circuit, overload, leakage, ground fault, arc fault
  • Solutions: Inspect cables and equipment to eliminate short-circuit risks; Reduce total load to avoid overload; Troubleshoot leakage protection circuits; Check earthing system for ground faults; Inspect arc fault points and replace damaged components

12.1.4 Cabinet Condensation & Corrosion

  • Causes: Excess ambient humidity, insufficient protection rating, poor internal ventilation
  • Solutions: Improve site ventilation and lower humidity; Upgrade to IP54 high-protection cabinets; Derust and repaint corroded cabinet surfaces

12.1.5 Damaged Seals & Suspected Electricity Theft

  • Causes: Deliberate human tampering and unauthorized modification of metering circuits
  • Solutions: Immediately report to local power supply authorities; Replace and reseal with new security seals; Restore original metering circuit wiring; Collect evidence for legal liability pursuit of electricity theft perpetrators

12.2 Standard Maintenance Procedures

12.2.1 Daily Inspection

  • Check cabinet exterior for deformation, corrosion and condensation
  • Verify meter display with normal voltage, current and power readings, no fault alarms
  • Inspect all security seals for intact condition without prying damage
  • Confirm communication module indicator lights and stable network connection

12.2.2 Monthly Maintenance (Once per Month)

  • Tighten all primary and secondary circuit terminals to prevent loose connections
  • Clean internal cabinet dust and maintain unobstructed ventilation
  • Calibrate energy meters, CT and PT to guarantee metering error ≤±0.2%
  • Test disconnector and MCCB operating mechanisms for flexible movement
  • Inspect surge arresters and earthing systems, ensure earthing resistance ≤4Ω

12.2.3 Annual Comprehensive Maintenance (Once per Year)

  • Full structural inspection of cabinet frames for welding cracks and corrosion
  • Replace aging cables, terminals and sealing rubber parts
  • Conduct mechanical life testing for disconnectors and MCCBs to validate performance
  • Upgrade firmware of communication modules and edge computing units for optimized functions
  • Complete insulation withstand voltage test: Primary circuit ≥2kV/1min, secondary circuit ≥1kV/1min
  • Sort maintenance records and establish complete equipment operation archives

12.2.4 Long-term Shutdown Maintenance

  • Disconnect all circuit breakers and cut off power supply
  • Fully clean cabinet interior and maintain dry, ventilated storage
  • Seal cabinet doors to prevent unauthorized access
  • Conduct monthly inspection to avoid condensation and corrosion
  • Complete full inspection and performance testing before re-commissioning to pass acceptance

13. Factory Strength & After-sales Service

13.1 Manufacturing Capacity

  • Production Scale: KITOZER operates a modern manufacturing base covering 20,000 ㎡ with 15,000 ㎡ production workshops, over 200 employees including 50 dedicated R&D engineers. Annual output exceeds 10,000 sets of low-voltage metering cabinets and power distribution equipment with stable delivery capacity.
  • R&D Capability: Professional R&D team focusing on low-voltage power distribution, energy metering and IoT technology. Annual R&D investment accounts for 15% of total revenue, with multiple invention patents, utility model patents and software copyrights, maintaining domestically leading technology aligned with international standards.
  • Advanced Production Equipment: Imported German CNC punching machines, laser cutters, bending machines, automatic spraying lines and assembly lines deliver high processing precision and consistent product quality.
  • Strict Quality Control: Certified ISO9001 Quality Management, ISO14001 Environmental Management and ISO45001 Occupational Health & Safety Management Systems. Every production stage undergoes strict inspection; all finished products pass 100% insulation withstand voltage testing, precision calibration and full function testing before delivery with 100% quality pass rate.
  • Stable Supply Chain: Long-term strategic cooperation with top domestic component suppliers for CT/PT, energy meters, circuit breakers and communication modules to guarantee stable component quality. Bulk raw material procurement delivers significant cost advantages and competitive product pricing.

13.2 After-sales Service Commitment

  1. Warranty Policy: All KITOZER low-voltage metering cabinets enjoy a 3-year free warranty; core components (CT/PT, energy meters, communication modules) carry a 5-year warranty. Free repair, component replacement or whole-unit exchange within warranty period with zero labor and travel fees; lifelong paid technical maintenance support available.
  2. 7×24 Technical Support: Round-the-clock remote technical guidance via phone, WeChat and email for fast fault resolution. Professional engineering team provides one-stop services including scheme design, technical disclosure, installation guidance and operation training; regular technical workshops to improve client on-site maintenance capabilities.
  3. On-site Installation & Commissioning: Professional installation teams deliver door-to-door assembly and debugging to guarantee standardized installation and stable operation. On-site hands-on training for client operation staff covering product functions, operation workflows and safety precautions.
  4. Nationwide Fast Response Network: Service outlets established across South China, East China, North China and Southwest China. Customer service requests responded within 24 hours; on-site technicians arrive within 48 hours (72 hours for remote rural areas) to minimize equipment downtime and economic losses.
  5. Customized Full-lifecycle Service: Custom non-standard design, OEM & ODM manufacturing available with confidential NDAs to protect client technical data. Full lifecycle asset management including periodic customer return visits, regular equipment inspection and professional maintenance recommendations to sustain long-term stable equipment performance.

14. Conclusion

As core metering equipment for high-voltage, low-voltage and new energy power distribution systems, KITOZER low-voltage metering cabinets fully comply with national and industrial standards, integrating high-precision metering, intelligent IoT monitoring, high-grade environmental protection and anti-electricity theft technology. The full series of basic, mid-range and high-end products cover all low-voltage metering scenarios including residential communities, commercial buildings, industrial plants, data centers and new energy grid connection.

With core strengths including ultra-precise measurement, regulatory compliance, high reliability, flexible customization, fast stock delivery and comprehensive after-sales support, our products have been successfully deployed in numerous key national projects with stable performance and consistent positive feedback from clients and the industry.

Moving forward, KITOZER will continuously increase R&D investment to optimize product performance and upgrade intelligent functions. We commit to delivering more accurate, smarter, reliable and cost-effective low-voltage metering solutions to advance smart grid construction, accelerate new energy development and support national carbon peaking & carbon neutrality goals, establishing long-term win-win partnerships with all clients.

15. SEO Search Keywords & Tags

15.1 Search Keywords

  • Core Keywords: KITOZER low-voltage metering cabinet, low-voltage metering cabinet, electric energy metering cabinet, 400V metering cabinet, new energy grid-connected metering cabinet, smart metering cabinet, charge control metering cabinet, data center metering cabinet
  • Long-tail Keywords: Low-voltage metering cabinet solution, low-voltage metering cabinet configuration list, Class 0.2S metering cabinet, IoT smart metering cabinet, PV grid-connected metering cabinet, energy storage metering cabinet, anti-electricity theft metering cabinet, remote meter reading metering cabinet
  • Regional Keywords: Guangdong low-voltage metering cabinet, Guangzhou low-voltage metering cabinet, Shenzhen low-voltage metering cabinet, Dongguan low-voltage metering cabinet, Foshan low-voltage metering cabinet

15.2 Tags

  • Product Tags: #KITOZER #LowVoltageMeteringCabinet #EnergyMeteringCabinet #SmartMeteringCabinet #HighPrecisionMetering #AntiTheftMeteringCabinet
  • Application Scenario Tags: #ResidentialMetering #CommercialBuildingMetering #IndustrialMetering #DataCenterMetering #NewEnergyGridConnection #PVAndEnergyStorageMetering
  • Technical Tags: #Class0.2SCT #IoT #5GCommunication #EdgeComputing #BlockchainDataStorage #PowerQualityMonitoring
Shopping Cart