Shielded Cabinet in Command Center
- Full-Band High-Efficiency Shielding: Three tiers (B/C/Military) covering 10kHz~40GHz, blocks 2G/3G/4G/5G/WiFi/Bluetooth signals to prevent information leakage and external interference.
- Precision Sealing Anti-Leakage: Imported beryllium copper spring strips embedded on door frames, full conductive gaskets at all joints to maintain continuous electromagnetic conduction and stable shielding performance without attenuation.
- High-Strength Durable Structure: Welded premium cold-rolled steel sheet, load capacity 800~1500kg, anti-seismic and anti-deformation for long-term stable computer room operation.
- Balanced Heat Dissipation & Shielding: Honeycomb waveguide windows paired with silent fans or liquid cooling solve heat dissipation challenges under sealed conditions to stabilize internal equipment.
- Safe & Reliable Protection: Multi-mode locks (mechanical/electronic/fingerprint), ultra-low resistance grounding (≤0.1Ω) and anti-pry design prevent unauthorized access and electric shock risks.
Table of Contents
Toggle8.2 Customization & Service Advantages

Large-Scale Computer Room Engineering Project
9.1 Shielded Cabinet Main Body
- ★Shielding Efficiency: Class C, ≥100dB from 50MHz to 1GHz, compliant with BMB19-2006 & GB/T 12190-2021
- ★Material Thickness: ≥2.0mm SPCC cold-rolled steel sheet, fully welded forming
- ★Load Capacity: ≥1200kg (mid-range & high-end models)
- ★Door Structure: Front & rear double shielded doors with electronic password lock + mechanical lock (mid-range & high-end)
- Standard Size: 600×800×2000mm (42U), custom dimensions supported
9.2 Ventilation Waveguide Window
- ★Shielding Efficiency: ≥80dB @1GHz (mid-range & high-end)
- Minimum Size: ≥400×400mm (mid-range & high-end)
9.3 Power Filter
- ★Insertion Loss: ≥60dB (10kHz~1GHz, mid-range & high-end)
- Minimum Rated Current: ≥16A (mid-range & high-end)
9.4 Signal Filter
- ★Insertion Loss: ≥50dB (100MHz~1GHz, mid-range & high-end)
- Minimum Interfaces: ≥8 RJ45 ports (mid-range & high-end)
9.5 Heat Dissipation Module
- ★Heat Dissipation Capacity: ≥5kW for high-end liquid cooling; air volume ≥500m³/h for mid-range fan models
- Temperature Control Precision: ±1℃ (liquid cooling high-end models)
9.6 High-End Intelligent Monitoring Unit
- ★Electromagnetic Detection Band: 10kHz~1GHz, field strength precision ±2dBμV/m
- ★Remote Monitoring: TCP/IP protocol support, real-time remote viewing of temperature/humidity/electromagnetic data and access records
9.7 Grounding Kit
- ★Ground Resistance: ≤0.5Ω (mid-range & high-end)
10. Full-Scenario Solution Packages
10.1 Confidential Computer Room Shielding Solution
Pain Points
Prevent electromagnetic leakage of confidential servers & computers, resist external eavesdropping signals and meet national confidentiality standards.
Configuration
KITOZER Class C 42U shielded cabinet + signal filter + power filter + intelligent monitoring unit + confidential-grade grounding kit
Advantages
Full-band shielding ≥100dB to block all leakage paths; real-time intelligent early warning; fully compliant with BMB19-2006 and state confidentiality certification standards.
10.2 Data Center Electromagnetic Protection Solution
Pain Points
Mutual electromagnetic interference between high-density servers, external interference from base stations & radar causes server downtime and data packet loss.
Configuration
KITOZER Class C 42U/48U shielded cabinet + liquid cooling module + full signal filter + remote monitoring system
Advantages
Isolates internal & external interference to stabilize server operation; liquid cooling reduces energy consumption for dense equipment; centralized remote monitoring improves operation & maintenance efficiency.
10.3 Industrial Control Anti-Interference Solution
Pain Points
Strong electromagnetic interference from inverters and motors in workshops leads to PLC crash and production line shutdown.
Configuration
KITOZER Class B/C 32U/42U shielded cabinet + power filter + reinforced grounding kit + dustproof sealing components
Advantages
Suppresses low & high-frequency industrial interference to stabilize control systems; dustproof sealing adapts harsh factory environments; easy installation for existing production line retrofits.
10.4 Scientific Research Pure Electromagnetic Environment Solution
Pain Points
External electromagnetic noise distorts precision instrument test results, requiring interference-free testing space.
Configuration
Custom military-grade KITOZER shielded cabinet + high-shielding waveguide window + electromagnetic monitoring module + independent grounding system
Advantages
≥100dB full-band shielding creates ultra-pure electromagnetic environment; real-time electromagnetic calibration ensures test accuracy; custom sizes fit all precision testing instruments.
11. Engineering Application Cases
11.1 Provincial Government Confidential Computer Room Project
Project Background
New provincial confidential computer room deploying confidential servers and workstations, requiring electromagnetic leakage prevention to meet Class 3 Cybersecurity & national confidentiality standards.
Deployment
20 sets of KITOZER Class C 42U shielded cabinets, each equipped with signal filters, power filters, intelligent monitoring units and confidential grounding kits.
Outcome
Actual shielding efficiency ≥100dB (50MHz~1GHz) with zero electromagnetic leakage; stable operation for 1 full year with real-time monitoring; passed State Secrets Administration acceptance and fully meets confidential information security requirements.
11.2 State-Owned Bank Core Data Center Retrofit Project
Project Background
Dense server deployment caused electromagnetic interference, triggering occasional transaction system lag and data loss, requiring electromagnetic protection upgrade.
Deployment
50 sets of KITOZER Class C 48U shielded cabinets with liquid cooling modules, full signal filters and centralized remote monitoring system.
Outcome
Complete elimination of electromagnetic interference with stable transaction systems; liquid cooling cuts energy consumption by 30%; centralized remote monitoring boosts O&M efficiency by 60%.
11.3 Automobile Manufacturing Workshop Industrial Control Project
Project Background
Dense welding inverters and motors generated severe electromagnetic interference, frequent PLC crashes and unplanned production line downtime with heavy economic losses.
Deployment
15 sets of KITOZER Class B 32U shielded cabinets with power filters, reinforced grounding kits and dustproof sealing assemblies.
Outcome
≥90% electromagnetic interference suppression rate, zero production line shutdown events; dustproof design extends service life of control equipment by 50%.
11.4 University EMC Laboratory Construction Project
Project Background
New EMC testing laboratory requires interference-free space for precision electronic device anti-interference performance testing.
Deployment
5 customized military-grade KITOZER shielded cabinets (800×1000×2200mm) with high-shielding waveguide windows, electromagnetic monitoring modules and independent dedicated grounding systems.
Outcome
≥100dB full-band shielding delivers ultra-clean electromagnetic environment; test accuracy improved to ±0.5dB with real-time electromagnetic calibration for all precision instrument testing demands.
12. Common Faults & Maintenance Specifications
12.1 Typical Fault Troubleshooting
- Fault 1: Degraded Shielding Efficiency / Excessive Electromagnetic Leakage
- Root Causes: Deformed/fallen door spring strips, aged conductive gaskets, poor grounding, clogged/damaged waveguide windows
- Troubleshooting: Inspect spring strip integrity and tight door fit; replace aged conductive gaskets; test ground resistance (≤0.5Ω); clean or replace broken waveguide windows.
- Fault 2: Excessive Internal Cabinet Temperature & Equipment Overheat Shutdown
- Root Causes: Broken cooling fans, clogged waveguide windows, faulty heat dissipation modules, overloaded equipment layout
- Troubleshooting: Test fan operation and replace damaged units; clear dust from waveguide windows; overhaul liquid cooling modules (high-end); rearrange internal equipment to limit rack utilization ≤60%.
- Fault 3: No Data / Abnormal Alerts on Intelligent Monitoring Unit
- Root Causes: Power supply failure, damaged sensors, network disconnection, incorrect configuration
- Troubleshooting: Inspect monitoring unit power supply; replace faulty temperature/humidity/electromagnetic sensors; test network cable connectivity; reconfigure system parameters and restart equipment.
- Fault 4: Lock Failure / Unintended Opening
- Root Causes: Dead electronic lock battery, incorrect password, fingerprint recognition failure (high-end), jammed mechanical lock
- Troubleshooting: Replace electronic lock batteries; reset access passwords; clean fingerprint sensor and re-register fingerprints; lubricate mechanical lock cylinder and clear foreign debris.
12.2 Standard Maintenance Procedures
Weekly Routine Inspection
- Appearance: Wipe cabinet dust; inspect door/panel deformation and rust.
- Sealing System: Check spring strips and conductive gaskets for intactness and tight fit, no loosening or detachment.
- Heat Dissipation: Clean dust from waveguide windows and fans to guarantee unobstructed airflow; test fan rotation status.
- Grounding: Verify tight ground wire connections with no rust or looseness; confirm ground resistance meets standards.
- Locks: Test smooth opening/closing without jamming or accidental release.
Monthly Maintenance
- Shielding Performance: Test shielding efficiency with professional instruments to ensure Class C ≥100dB @1GHz.
- Intelligent Monitoring: Calibrate temperature/humidity/electromagnetic sensors; test remote monitoring and alarm functions.
- Cabling: Inspect power & signal cables for tight connections, no aging or damage, normal filter performance.
Annual Overhaul
- Full Disassembly Inspection: Remove doors and panels to inspect internal shielding structure and welding seams for cracks or rust.
- Consumable Replacement: Swap aged conductive gaskets, spring strips, fans and filters.
- Full Performance Calibration: Complete full-band shielding test, intelligent monitoring calibration and ground resistance retest; issue formal maintenance report.
Long-Term Storage Maintenance
Store cabinets in dry, ventilated space away from humidity and direct sunlight; power on and ventilate monthly to prevent internal moisture and rust; apply anti-rust oil to lock mechanisms for smooth operation.
13. Factory Strength & After-Sales Service
13.1 Manufacturer Profile: Guangzhou Lai’an Intelligent System Development Co., Ltd.
- Enterprise Qualifications: Founded in 2002, National High-Tech Enterprise, ISO9001 Quality Management System, ISO14001 Environmental Management System, GJB9001C Military Quality System certified. Owns brand KITOZER and over 20 patents for electromagnetic shielding equipment.
- Production Base: 10,000㎡ modern manufacturing plant in Panyu, Guangzhou with 5 standardized workshops; equipped with CNC bending machines, laser cutters, automatic welding lines, electrostatic spraying workshops and dedicated shielding efficiency testing labs; annual output exceeds 5,000 shielded cabinets.
- Technical R&D Team: 30+ professional engineers including 10 senior electromagnetic shielding specialists with over 10 years industry experience; industry-university-research cooperation with universities and research institutes for continuous technical iteration, domestic leading and internationally advanced product performance.
- Full-Process Quality Control: Raw material incoming inspection, in-process sampling testing, 100% finished product shielding efficiency testing and aging test before delivery; third-party certification by CEPREI and National Secret Science & Technology Evaluation Center to guarantee stable product quality.
13.2 After-Sales Service System
- Warranty Commitment: 3-year free full-unit warranty starting from project acceptance; free repair and replacement of non-artificial damaged parts within warranty period; core shielding structures and filters carry 5-year extended warranty.
- Rapid Response Support: National 7×24-hour technical hotline, 1-hour initial response for fault inquiries, complete solution within 4 hours; on-site service within 24~48 hours for core cities, coordinated local service outlets for remote regions.
- Free Installation & Commissioning: Professional on-site cabinet positioning, grounding, cable routing and system configuration guidance; on-site shielding efficiency testing post-installation to verify compliance with standards.
- Technical Training: Free on-site or online training covering product principles, operation, routine maintenance and fault troubleshooting; issue operation certificates after training to enable independent user maintenance.
- Lifelong Customized Support: Permanent free technical consultation and scheme optimization; product upgrade and transformation support; quarterly regular follow-up visits to assess equipment operation and provide maintenance recommendations.
- Spare Parts Inventory: Regional spare parts warehouses in major cities with full stock of common consumables (spring strips, gaskets, fans, filters) to minimize equipment downtime.
14. Conclusion
As core electromagnetic shielding equipment for information security protection, KITOZER shielded cabinets draw on 20 years of electromagnetic shielding technology accumulation, military-grade manufacturing standards and full-scenario customization capabilities to deliver efficient, stable and reliable electromagnetic protection solutions for confidential computer rooms, data centers, industrial control and scientific testing industries.
All products strictly comply with national confidentiality standards and industry specifications, with domestic leading core indicators including shielding efficiency, structural strength and heat dissipation performance, certified by the National Administration for State Secrets Protection and authoritative third-party testing institutions. KITOZER is the preferred brand for information security protection projects.
Guangzhou Lai’an Intelligent System Development Co., Ltd. will continue to deepen electromagnetic shielding R&D and innovation, optimize product performance and service systems, adhering to the corporate philosophy of “Technological Innovation, Quality Priority, Service-Oriented”. We provide safer, more efficient and intelligent electromagnetic shielding products and solutions for all industries, supporting national information security and enterprise data security construction.
15. Search Keywords & SEO Tags
15.1 Core & Long-Tail Search Keywords
Core Keywords
Shielded Cabinet, Electromagnetic Shielded Cabinet, Confidential Shielded Cabinet, KITOZER Shielded Cabinet, Pioneer Shielded Cabinet
Long-Tail Keywords
Class C Shielded Cabinet, Class B Shielded Cabinet, Military-Grade Shielded Cabinet, Server Shielded Cabinet, Computer Room Shielded Cabinet, Anti-Electromagnetic Interference Cabinet, Confidential Computer Room Shielding Equipment, Data Center Shielded Cabinet, Industrial Control Shielded Cabinet, Shielded Cabinet Manufacturer, Custom Shielded Cabinet, Shielded Cabinet Solution
15.2 SEO Optimization Tags
- Title Tag: KITOZER Shielded Cabinet | Electromagnetic Shielded Cabinet | Confidential Computer Room Shielding Equipment | Guangzhou Lai’an Intelligent
- Meta Description Tag: KITOZER provides professional electromagnetic shielded cabinets, confidential Class C and military-grade shielded cabinets for confidential computer rooms, data centers and industrial control scenarios. Direct from manufacturer with customized solutions and state confidentiality certification.
- Meta Keywords Tag: Shielded Cabinet, Electromagnetic Shielded Cabinet, Confidential Shielded Cabinet, Class C Shielded Cabinet, Military-Grade Shielded Cabinet, KITOZER, Guangzhou Lai’an Intelligent
15.3 Website Classification & Scenario Tags
Classification Tags
Electromagnetic Shielding Security Equipment, Information Security Equipment, Computer Room Equipment, Electromagnetic Protection Equipment
Scenario Tags
Confidential Computer Room, Data Center, Industrial Control, Scientific Research Testing, Financial Computer Room, Military Equipment