KITOZER
KITOZER

KITOZER DC Power Distribution Unit Cabinet Solution

Table of Contents

1. System Overview

The KITOZER DC power distribution unit cabinet is the core equipment of new energy power distribution systems. It focuses on centralized distribution, intelligent scheduling, safety protection and real-time monitoring of DC electric energy under high-voltage, low-voltage and new energy scenarios. It connects rectifier modules, energy storage battery packs and DC loads to build an efficient, stable and reliable DC power supply network.

The equipment adapts to DC power supply demands of photovoltaic power generation, wind power, energy storage, data centers, communication base stations, industrial control and other scenarios, supporting mainstream voltage levels including DC48V/110V/220V/380V/1000V. It is equipped with full-dimensional functions such as overload, short-circuit, overvoltage, undervoltage, insulation monitoring and remote operation & maintenance. Its modular design enables flexible capacity expansion, and customized configuration can be realized according to low, medium and high-tier requirements to achieve standardized, intelligent and safe deployment of new energy DC power distribution systems.

image

KITOZER DC Distribution Unit Cabinet

2. System Composition

The KITOZER DC power distribution unit cabinet consists of eight core components: cabinet structure, main power distribution circuit, intelligent monitoring unit, protection unit, lightning protection & grounding unit, communication interface unit, heat dissipation unit and terminal block unit. All modules coordinate to guarantee stable system operation.

  1. Cabinet Structure Adopts high-strength cold-rolled steel / stainless steel, with IP40 (standard) / IP54 (outdoor) protection grade, featuring dustproof, waterproof and anti-corrosion performance. It delivers excellent heat dissipation and electromagnetic shielding performance, supporting floor-standing, wall-mounted and 19-inch cabinet installation modes.
  2. Main Power Distribution Circuit Comprises DC main busbar, input circuit breaker, output branch circuit breaker, fuse, shunt and copper bar connectors. It undertakes the introduction, bus collection and multi-channel distribution of DC power. The main busbar is made of high-conductivity copper with strong current-carrying capacity and low temperature rise.
image
  1. Intelligent Monitoring Unit Integrates voltage/current/temperature acquisition modules, LCD display panel, alarm module and data storage module. It monitors real-time parameters including system input/output voltage, current, power, battery status and ambient temperature, supporting local display and alarm prompts.
  2. Protection Unit Equipped with overcurrent protection, short-circuit protection, overvoltage/undervoltage protection, polarity protection, insulation monitoring protection, primary & secondary power-off protection, etc. It rapidly cuts off faulty branches upon faults to protect the system and loads.
  3. Lightning Protection & Grounding Unit Built-in Class B/C DC surge protective device (SPD) to suppress lightning surge impact; dedicated ground copper bars for working ground and protective ground are configured, with grounding resistance ≤0.5Ω to ensure personal and equipment grounding safety.
  4. Communication Interface Unit Standard RS485 (Modbus RTU); optional Ethernet (IEC61850) and CAN bus. It supports remote monitoring, data uploading and remote switching control to meet IoT operation & maintenance demands.
  5. Heat Dissipation Unit Combines intelligent temperature-controlled fans and natural heat dissipation. Fans automatically start and stop according to internal cabinet temperature, ensuring stable equipment operation in a wide temperature range of -25℃~+60℃.
  6. Terminal Block Unit Adopts high-insulation, high-current terminal blocks. Input and output circuits are clearly partitioned for convenient and firm wiring, facilitating later maintenance and capacity expansion.

3. System Classification

The KITOZER DC power distribution unit cabinet is categorized by four dimensions: voltage level, configuration tier, installation mode and application scenario, covering all DC power distribution demands.

3.1 Classification by Voltage Level

  • Low-voltage DC Power Distribution Unit (DC48V/110V/220V) Applicable to communication base stations, data centers, industrial control, low-voltage side of energy storage and other scenarios, with rated current ranging from 10A to 1000A.
  • High-voltage DC Power Distribution Unit (DC380V/500V/1000V) Applicable to photovoltaic convergence, wind power converter, high-voltage side of energy storage, new energy vehicle charging piles, HVDC power supply for large data centers and other scenarios, with rated current ranging from 50A to 2000A.
image
  • Basic Tier (Low Configuration) Meets basic power distribution and protection requirements without intelligent monitoring. Equipped with simple circuit breakers, fuses and SPDs, suitable for small computer rooms and simple energy storage scenarios.
  • Intelligent Tier (Medium Configuration) Integrates basic monitoring functions (voltage/current display, basic alarms) with standard RS485 communication, supporting local operation and simple remote monitoring. Suitable for small & medium-sized data centers, communication base stations and conventional energy storage scenarios.
  • Flagship Tier (High Configuration) Full intelligent configuration integrating insulation monitoring, temperature monitoring, harmonic monitoring, fault recording, remote operation & maintenance and data storage (≥1000 records), as well as multi-level permission management. Supports Ethernet / CAN bus, applicable to large data centers, photovoltaic power stations, wind power bases, large energy storage power stations and other high-end scenarios.

3.3 Classification by Installation Mode

  • Floor-standing Type: Large capacity and multi-circuit configuration, cabinet size 800×600×2200mm, suitable for computer rooms, power distribution rooms and energy storage power stations.
  • Wall-mounted Type: Miniaturized and lightweight, cabinet size 400×300×600mm, suitable for base stations, outdoor cabinets and small computer rooms with limited space.
  • 19-inch Rack-mounted Type: Standard cabinet installation, adapted to data center cabinets and integrated cabinets for convenient integrated deployment.

3.4 Classification by Application Scenario

  • DC Power Distribution Unit Dedicated to New Energy Storage: Adapted to charge-discharge management of energy storage battery packs, supporting bidirectional current, battery polarity protection, insulation monitoring and charge-discharge current limiting control.
  • DC Power Distribution Unit Dedicated to Photovoltaic / Wind Power: Adapted to photovoltaic combiner boxes and wind power converter output, supporting high voltage, large current, reverse connection prevention, lightning protection and MPPT adaptation.
  • DC Power Distribution Unit Dedicated to Data Centers / Communication: Adapted to DC48V/380V power supply systems, supporting multi-channel output, load priority management, primary & secondary power-off and remote operation & maintenance.
  • DC Power Distribution Unit Dedicated to Industrial Control: Adapted to power supply for industrial equipment, PLCs and sensors, supporting wide-temperature operation, anti-electromagnetic interference and high stability.

4. System Schematic Diagram

image

4.1 Low-voltage DC Power Distribution Schematic (DC48V/220V)

  1. AC input → Rectifier module → DC bus → Input circuit breaker of DC distribution unit → Main busbar → Branch circuit breaker / Fuse → DC load
  2. Battery packs are connected in parallel to the DC bus; the system automatically switches to battery power supply when mains power fails.
  3. The monitoring unit collects bus voltage, total current, branch currents and battery temperature, and uploads data to local display or remote platform.
  4. SPD is connected in parallel on the input side to suppress surges; the insulation monitoring module monitors bus-to-ground insulation resistance and sends alarms upon abnormalities.

4.2 High-voltage DC Power Distribution Schematic (DC380V/1000V)

  1. Photovoltaic array / Wind power converter → DC convergence → Input isolating switch of high-voltage DC distribution unit → Main busbar → Branch circuit breaker → Inverter / High-voltage load
  2. Energy storage battery packs are connected to the DC bus via bidirectional DC/DC converters to realize bidirectional energy flow.
  3. Equipped with high-voltage DC SPD, insulation monitoring device and overvoltage protection device to ensure high-voltage system safety.
  4. The intelligent monitoring unit supports high-voltage parameter collection, fault recording and remote switching, adapting to high-voltage new energy scenarios.

Note: The actual schematic diagram contains detailed electrical component symbols, terminal numbers and communication interface definitions, which can be customized according to configuration tiers. The high-tier version adds harmonic monitoring, fault location and dual-power switching circuits.

image

5. Full System Configuration List (Low / Medium / High Tier)

5.1 Basic Tier (Low Configuration) List

表格

No.Product NameModelTechnical ParametersQtyUnitBrandRemarks
1DC Distribution CabinetKT-DC-B-400Material: Cold-rolled steel; IP40 protection; Size:400×300×600mm; Wall-mounted; Color RAL70351SetKITOZERBasic model, dust & corrosion resistant
2DC Input Circuit BreakerKT-DC-B-100Rated DC220V, 100A; Breaking capacity 10kA; 2P; Overload & short-circuit protection1SetKITOZERMain circuit input protection
3DC Output Circuit BreakerKT-DC-B-32Rated DC220V,32A; Breaking capacity 6kA;2P; Overload & short-circuit; 4 circuits4SetKITOZERBranch output protection
4DC FuseKT-DC-F-63Rated DC220V,63A; Breaking capacity20kA; RT18 type2PcsKITOZERSpare circuit protection
5DC SPDKT-DC-SPD-220Rated DC220V; Max discharge capacity40kA; Class B; Response time ≤25ns1PcsKITOZERInput side lightning protection
6Copper BusbarKT-CU-40×4T2 copper; 40×4mm; 500A carrying capacity; Tin-plated surface5MKITOZERMain circuit convergence
7Terminal BlockKT-TB-100ARated 100A; Withstand DC500V; Flame-retardant PA6620PcsKITOZERCircuit wiring
8Cooling FanKT-FAN-12038DC24V,10W; Air volume120CFM; Service life50,000h1SetKITOZERCabinet heat dissipation

5.2 Intelligent Tier (Medium Configuration) List

表格

No.Product NameModelTechnical ParametersQtyUnitBrandRemarks
1DC Distribution CabinetKT-DC-M-800Cold-rolled steel; IP40; 800×600×2200mm floor-standing; RAL7035; EMI shielding ≥30dB1SetKITOZERIntelligent floor-standing cabinet with superior shielding
2DC Input Circuit BreakerKT-DC-M-250Rated DC380V,250A; Breaking capacity20kA;2P; Overload/short-circuit/undervoltage; Optional electric operation1SetKITOZERIntelligent main input protection
3DC Output Circuit BreakerKT-DC-M-63Rated DC380V,63A; Breaking capacity10kA;2P; Overload/short-circuit; 8 circuits8SetKITOZERBranch intelligent protection
4Intelligent Monitoring UnitKT-MON-MMonitors voltage/current/temp; LCD display; RS485 Modbus RTU; Acoustic & light alarm; 200 records storage; Voltage accuracy ≤±0.5%, current ≤±1%1SetKITOZERCore system monitoring
5DC SPDKT-DC-SPD-380Rated DC380V; Max discharge60kA; Class B/C; Response ≤20ns; Failure indicator1PcsKITOZERSecondary input lightning protection
6Insulation Monitoring ModuleKT-IM-MDC0~500V monitoring; 0~10MΩ insulation resistance; Accuracy ≤±5%; Alarm threshold 1MΩ; Dry contact output1SetKITOZERBus insulation monitoring
7ShuntKT-SH-300ARated 300A; 0.2 accuracy class; 75mV output signal; Manganese copper material1PcsKITOZERCurrent sampling
8Copper BusbarKT-CU-60×5T2 copper;60×5mm;800A carrying capacity; Tin-plated with insulating sheath8MKITOZERMain circuit convergence
9Terminal BlockKT-TB-200ARated200A; Withstand DC1000V; Flame-retardant PA66; Anti-electric shock design30PcsKITOZERCircuit wiring
10Intelligent Temp-controlled FanKT-FAN-MDC24V,15W; Air volume180CFM; Temp trigger 25~45℃; Service life80,000h; Low noise2SetKITOZERIntelligent heat dissipation
11Indicator LightKT-LAMP-DCDC220V; Red (alarm) / Green (running); Service life100,000h4PcsKITOZERStatus indication

5.3 Flagship Tier (High Configuration) List

表格

No.Product NameModelTechnical ParametersQtyUnitBrandRemarks
1DC Distribution CabinetKT-DC-H-1000304 stainless steel; IP54; 1000×800×2200mm floor-standing; Raw stainless steel finish; EMI shielding ≥50dB; C4 anti-corrosion grade1SetKITOZERFlagship outdoor stainless steel cabinet
2DC Input IsolatorKT-DC-H-1000Rated DC1000V,1000A; Breaking capacity50kA;2P; Overload/short-circuit/overvoltage/undervoltage; Standard electric operation; Mechanical life 20,000 times1SetKITOZERHigh-voltage main circuit isolation protection
3Intelligent DC Output Circuit BreakerKT-DC-H-250Rated DC1000V,250A; Breaking capacity30kA;2P; Overload/short-circuit/leakage/overtemp;12 circuits; Remote switching support12SetKITOZERHigh-voltage branch intelligent protection
4Flagship Monitoring UnitKT-MON-HMonitors voltage/current/power/temp/harmonic/insulation resistance; 7-inch touch screen; RS485+Ethernet(IEC61850)+CAN bus; Acoustic/light/SMS/APP alarm; 1000 records storage; Voltage accuracy ≤±0.2%, current ≤±0.5%; Fault recording & remote O&M1SetKITOZERFull-function intelligent monitoring
5Three-stage DC SPDKT-DC-SPD-1000Rated DC1000V; Max discharge100kA; Class B/C/D; Response ≤15ns; Failure indicator & remote alarm3PcsKITOZERThree-stage lightning protection
6High-precision Insulation Monitoring ModuleKT-IM-HDC0~1500V monitoring; 0~100MΩ insulation resistance; Accuracy ≤±2%; Alarm threshold0.5MΩ; Dry contact + communication output; Fault location function1SetKITOZERHigh-voltage precise insulation monitoring
7High-precision ShuntKT-SH-1000ARated1000A; 0.1 accuracy class;75mV signal; Manganese copper with temperature compensation1PcsKITOZERHigh-precision current sampling
8Harmonic Monitoring ModuleKT-HM-HMonitors 2~50 harmonics; Accuracy ≤±3%; Communication support; Adjustable alarm threshold1SetKITOZERSystem harmonic monitoring
9Copper BusbarKT-CU-80×6T2 copper;80×6mm;1200A carrying capacity; Tin-plated, insulating sheath & anti-corrosion treatment10MKITOZERHigh-voltage heavy current convergence
10High-voltage Terminal BlockKT-TB-500ARated500A; Withstand DC2000V; Flame-retardant PA66 & silver-plated copper; Anti-electric shock; 5000V/1min withstand voltage40PcsKITOZERHigh-voltage circuit wiring
11Intelligent Heat Dissipation SystemKT-FAN-HDC24V,20W; Air volume240CFM; Temp trigger 20~50℃; Service life100,000h; Low noise; 2+1 redundant backup3SetKITOZERHigh-voltage cabinet intelligent cooling
12Dual-power Switch ModuleKT-TS-HSwitch DC1000V; Switch current500A; Switch time ≤10ms; Redundant switching & fault alarm1SetKITOZERDual-power redundant power supply
13Fault RecorderKT-FR-HSampling frequency10kHz; 10s recording duration; ≥8GB storage; Communication support; Automatic fault analysis1SetKITOZERPrecise fault recording & analysis

6. Full Product Technical Specifications

6.1 Cabinet Specifications

  • Material: Low tier: Cold-rolled steel; Medium tier: Cold-rolled steel; High tier: 304 stainless steel
  • Protection Grade: Low/Medium tier: IP40; High tier: IP54
  • Dimensions (L×W×H): Low tier:400×300×600mm (wall-mounted); Medium tier:800×600×2200mm (floor-standing); High tier:1000×800×2200mm (floor-standing)
  • Installation Mode: Low tier: Wall-mounted; Medium tier: Floor-standing / 19-inch rack; High tier: Floor-standing
  • Operating Environment: Temperature -25℃~+60℃; Humidity ≤95% RH (non-condensing); Altitude ≤3000m (High tier up to 5000m)
  • EMI Shielding: Medium tier ≥30dB; High tier ≥50dB
image

6.2 DC Circuit Breaker / Isolator Specifications

  • Rated Voltage: Low tier DC220V; Medium tier DC380V; High tier DC1000V
  • Rated Current: Low tier Input100A / Output32A; Medium tier Input250A / Output63A; High tier Input1000A / Output250A
  • Breaking Capacity: Low tier 6~10kA; Medium tier10~20kA; High tier30~50kA
  • Protection Functions: Low tier Overload/Short-circuit; Medium tier Overload/Short-circuit/Undervoltage; High tier Overload/Short-circuit/Overvoltage/Undervoltage/Leakage/Over-temperature
  • Mechanical Service Life: Low tier ≥10,000 times; Medium tier ≥15,000 times; High tier ≥20,000 times

6.3 Intelligent Monitoring Unit Specifications

  • Monitored Parameters: Low tier: None; Medium tier: Voltage/Current/Temperature; High tier: Voltage/Current/Power/Temperature/Harmonic/Insulation Resistance
  • Display: Low tier: None; Medium tier: LCD; High tier:7-inch Touch Screen
  • Communication Interfaces: Low tier: None; Medium tier: RS485 Modbus RTU; High tier: RS485+Ethernet(IEC61850)+CAN Bus
  • Measurement Accuracy: Medium tier Voltage ≤±0.5%, Current ≤±1%; High tier Voltage ≤±0.2%, Current ≤±0.5%
  • Data Storage: Medium tier 200 records; High tier 1000 records
image

6.4 DC SPD Specifications

  • Rated Voltage: Low tier DC220V; Medium tier DC380V; High tier DC1000V
  • Max Discharge Capacity: Low tier40kA; Medium tier60kA; High tier100kA
  • Protection Class: Low tier Class B; Medium tier Class B/C; High tier Class B/C/D
  • Response Time: Low tier ≤25ns; Medium tier ≤20ns; High tier ≤15ns

6.5 Insulation Monitoring Module Specifications

  • Monitoring Voltage Range: Medium tier DC0~500V; High tier DC0~1500V
  • Insulation Resistance Range: Medium tier0~10MΩ; High tier0~100MΩ
  • Measurement Accuracy: Medium tier ≤±5%; High tier ≤±2%
  • Alarm Threshold: Medium tier1MΩ; High tier0.5MΩ

6.6 Copper Busbar Specifications

  • Material: High-conductivity T2 copper
  • Current Carrying Capacity: Low tier500A; Medium tier800A; High tier1200A
  • Surface Treatment: Tin-plated (anti-oxidation); High tier adds insulating sheath & anti-corrosion coating

7. Full Product Application Scope

7.1 Low-voltage DC Distribution Unit (DC48V/110V/220V)

  • Communication Industry: 4G/5G base stations, communication computer rooms, core network & transmission equipment power supply
  • Data Centers: Small & medium DC48V power supply for servers, switches and storage devices
  • Industrial Control: DC power supply for industrial PLCs, sensors, inverters and automation equipment
  • Low-voltage Energy Storage: Charge-discharge management for small lead-acid/lithium battery packs, household energy storage systems
  • Rail Transit: DC power supply for subway/light rail control equipment and lighting systems

7.2 High-voltage DC Distribution Unit (DC380V/500V/1000V)

image
  • New Energy Storage: High-voltage side charge-discharge management for large lithium/flow battery energy storage power stations, PCS interfaces
  • Photovoltaic Power Stations: Converged output of centralized/distributed PV combiner boxes, DC side distribution of PV inverters, PV+energy storage hybrid systems
  • Wind Power Industry: DC side distribution of wind power converters, supporting wind energy storage systems
  • Large Data Centers: HVDC (380V) power supply for AI servers and high-power cabinets
  • New Energy Vehicles: DC distribution for charging piles, battery management for swap stations, vehicle high-voltage power distribution systems
  • High-voltage Industrial Scenarios: High-voltage DC power supply for metallurgy, chemical and mining equipment, high-voltage motor control

7.3 Application Segmentation by Configuration Tier

  • Basic Tier (Low Configuration): Small computer rooms, simple base stations, household energy storage and small industrial equipment with limited budget & basic function demands
  • Intelligent Tier (Medium Configuration): Small & medium data centers, communication base stations, conventional energy storage power stations and industrial control rooms requiring basic monitoring & remote management
  • Flagship Tier (High Configuration): Large data centers, photovoltaic power stations, wind power bases, large energy storage power stations and high-end industrial scenarios requiring full intelligent monitoring, fault location and remote O&M with ultra-high reliability

8. Product Advantages

8.1 Core Functional Features

  • High Reliability Design: Industrial-grade components with redundant key parts; Wide operating temperature -25℃~+60℃, anti-vibration & anti-electromagnetic interference; MTBF ≥100,000 hours (High tier ≥150,000 hours)
  • Full-dimensional Safety Protection: Integrated overload, short-circuit, overvoltage, undervoltage, polarity, insulation monitoring, lightning protection and primary & secondary power-off protection; Fault response time ≤10μs to avoid fault propagation
  • Intelligent Monitoring & O&M: Medium & high tiers integrate intelligent monitoring system for real-time parameter tracking, local display and acoustic-light alarms; High tier supports remote O&M, APP/SMS alarms, fault recording and remote switching to cut O&M costs
  • Modular Flexible Configuration: Modular cabinet, distribution circuit and monitoring modules support flexible switching among low/medium/high tiers; Expandable circuits (4~12 channels) to meet capacity expansion demands of various scenarios
  • High Energy Efficiency: Low-loss circuit breakers and high-conductivity copper bars deliver system efficiency ≥99%; Intelligent cooling fans activate on demand to reduce power consumption; DC power supply eliminates inverter links, saving 3%~5% energy vs traditional UPS
image

8.2 Customization & Service Advantages

  • In-depth Customization: Customizable voltage grade (DC48V~1000V), rated current, circuit quantity, cabinet size, installation mode and communication protocol to fit special scenario demands
  • OEM/ODM Service: Provide OEM & ODM processing, supporting customer brand, parameter and appearance customization; Short mass production cycle with stable quality
  • Strict Confidentiality Mechanism: Sign non-disclosure agreements to strictly protect customized schemes, technical parameters, drawings and other core data against technical leakage
  • Fast Stock Delivery: Regular low/medium tier products are in stock with 3~7-day delivery; Custom high tier products delivered within 15~30 days to meet urgent project demands

8.3 Technical Parameter Advantages

  • High-precision Collection: High tier monitoring unit voltage accuracy ≤±0.2%, current ≤±0.5% for precise system parameter tracking
  • High Breaking Capacity: DC circuit breaker max breaking capacity up to 50kA to rapidly cut severe short-circuit faults and protect equipment
  • Wide Voltage Adaptation: Covers full voltage grades DC48V~1000V to satisfy all low & high-voltage DC power distribution scenarios
  • Strong Environmental Adaptability: Max IP54 protection grade for outdoor installation; Compliant with IEC 60068-2-6 anti-vibration standard to adapt to harsh industrial & outdoor environments

9. Bid Tender Technical Parameters (Marked with *)

    • Cabinet Material: Low tier cold-rolled steel; Medium tier cold-rolled steel; High tier 304 stainless steel; Protection grade ≥IP40 (High tier ≥IP54)
    • Rated Voltage: Optional DC48V/110V/220V/380V/1000V to fit low/high voltage and new energy scenarios
    • Rated Current: Input circuit ≥100A (Low) /250A (Medium) /1000A (High); Output circuit ≥32A (Low) /63A (Medium) /250A (High)
    • Breaking Capacity: DC circuit breaker breaking capacity ≥6kA (Low) /10kA (Medium) /30kA (High) for rapid fault disconnection
    • Protection Functions: Equipped with overload, short-circuit, overvoltage and undervoltage protection; Medium & high tiers add insulation monitoring and lightning protection; High tier adds leakage & over-temperature protection
    • Monitoring Accuracy: Medium tier voltage measurement ≤±0.5%, current ≤±1%; High tier voltage ≤±0.2%, current ≤±0.5%
    • Communication Interfaces: Medium tier standard RS485 Modbus RTU; High tier supports RS485+Ethernet(IEC61850)+CAN bus for remote O&M
    • Operating Environment: Temperature range -25℃~+60℃, humidity ≤95% RH (non-condensing), altitude ≥3000m (High tier ≥5000m)
    • Insulation Monitoring: Medium tier monitoring range 0~10MΩ, alarm threshold ≤1MΩ; High tier range 0~100MΩ, alarm threshold ≤0.5MΩ
    • Lightning Protection: Equipped with Class B or higher SPD, max discharge capacity ≥40kA (Low) /60kA (Medium) /100kA (High)
    • Mechanical Service Life: DC circuit breaker mechanical life ≥10,000 times (Low) /15,000 times (Medium) /20,000 times (High) for long-term stable operation
    • MTBF: System mean time between failures ≥100,000 hours (Low/Medium) /150,000 hours (High)

10. Product Solutions

10.1 New Energy Storage DC Power Distribution Solution

  • Solution Overview: Tailored for charge-discharge management of lithium/lead-acid/flow battery packs. Adopts KITOZER high/low voltage DC distribution units integrating bidirectional current management, battery polarity protection, insulation monitoring, charge-discharge current limiting and remote O&M functions, connecting PCS and battery packs to ensure safe and efficient charge-discharge of energy storage systems.
  • Recommended Configuration: Small energy storage (≤500kWh): Medium tier (DC220V/380V); Large energy storage power station (≥1MWh): High tier (DC500V/1000V) supporting bidirectional current, fault recording and remote O&M
  • Core Advantages: Supports bidirectional battery pack charge-discharge flow to avoid reverse connection faults; Precise insulation monitoring locates grounding faults; Real-time remote battery status monitoring extends battery service life

10.2 Photovoltaic / Wind Power DC Power Distribution Solution

  • Solution Overview: Adapted to PV combiner boxes and wind power converter DC side output. Adopts KITOZER high-voltage DC distribution units (DC500V/1000V) integrating reverse connection prevention, high-voltage lightning protection, insulation monitoring and MPPT adaptation to realize convergence, distribution and protection of PV/wind power energy, matching PV inverter and wind power converter access demands.
  • Recommended Configuration: Distributed PV (≤1MW): Medium tier (DC500V); Centralized PV / Wind power base (≥5MW): High tier (DC1000V) supporting three-stage lightning protection, harmonic monitoring and fault location
  • Core Advantages: High-voltage heavy current design fits high output voltage of PV/wind power; Reverse connection protection prevents component damage from reversed polarity; Three-stage lightning protection withstands outdoor lightning surges to adapt to harsh outdoor environments

10.3 Data Center / Communication DC Power Distribution Solution

  • Solution Overview: Developed for DC48V/380V HVDC power supply of data centers and DC48V power supply of communication base stations. Adopts low-voltage KITOZER DC distribution units integrating multi-channel output, load priority management, primary & secondary power-off and remote O&M to guarantee uninterrupted power supply for core equipment and reduce energy consumption & O&M costs.
  • Recommended Configuration: Small & medium data centers / Base stations: Medium tier (DC48V/380V); Large data centers (≥1000 cabinets): High tier (DC380V) supporting automatic load priority switching, remote switching and energy consumption monitoring
  • Core Advantages: DC power supply eliminates inverter links to save 3%~5% energy; Primary & secondary power-off protection cuts non-critical loads first to secure core equipment power supply; Intelligent monitoring tracks real-time energy consumption to lower data center PUE below 1.2

10.4 Industrial Control DC Power Distribution Solution

  • Solution Overview: Suited for DC power supply of industrial PLCs, sensors, inverters and automation equipment. Adopts low-voltage KITOZER DC distribution units integrating wide-temperature operation and anti-electromagnetic interference for harsh industrial environments (high temperature, dust, strong EMI) to stabilize industrial equipment operation.
  • Recommended Configuration: Small industrial equipment: Low tier (DC220V); Medium industrial control systems: Medium tier (DC220V/380V); Large industrial production lines: High tier (DC380V) supporting anti-vibration, wide-temperature operation and remote O&M
  • Core Advantages: Industrial-grade components with anti-vibration & anti-electromagnetic interference performance; Wide temperature range -25℃~+60℃ fits high-temperature workshops and outdoor industrial sites; High stability design ensures continuous production line operation

11. Application Cases

11.1 Large Centralized PV Power Station DC Distribution Project

  • Project Profile: 100MW centralized PV power station in northwest Gobi with high temperature, drought and sandstorm conditions. 20 sets of DC1000V high-voltage DC distribution units deployed for power distribution and protection after PV array convergence.
  • Product Configuration: KITOZER High Tier DC Distribution Unit (DC1000V/1000A), IP54 304 stainless steel cabinet, three-stage SPD, insulation monitoring and remote O&M
  • Application Effect: Stable operation for 3 years without major faults; Insulation monitoring accurately located 2 grounding faults to avoid equipment damage; Remote O&M cut on-site staff by 50% and reduced O&M costs; Excellent protection performance adapts to harsh Gobi environment

11.2 Large Lithium Energy Storage Power Station DC Distribution Project

  • Project Profile: 50MW/100MWh lithium energy storage power station for grid peak regulation and new energy consumption. 15 sets of DC500V high-voltage DC distribution units deployed for battery pack charge-discharge management.
  • Product Configuration: KITOZER High Tier DC Distribution Unit (DC500V/800A) with bidirectional current design, insulation monitoring, fault recording and remote O&M
  • Application Effect: Safe battery pack charge-discharge management with efficiency ≥98%; Insulation monitoring detected 3 battery insulation aging issues in advance to eliminate safety hazards; Real-time remote battery monitoring extended battery service life by 20%

11.3 Medium-sized Data Center DC Distribution Project

  • Project Profile: 500-cabinet medium data center adopting DC380V HVDC power supply system, equipped with 8 sets of DC distribution units for servers, switches and other IT equipment power supply.
  • Product Configuration: KITOZER Medium Tier DC Distribution Unit (DC380V/250A), multi-channel output, load priority management, RS485 communication and remote monitoring
  • Application Effect: DC system energy efficiency reaches 97%, saving 4% energy vs traditional UPS; Primary & secondary power-off protection ensures uninterrupted core equipment power supply with reliability up to 99.999%; Intelligent real-time energy consumption monitoring reduced data center PUE below 1.2

11.4 5G Communication Base Station DC Distribution Project

  • Project Profile: Mountainous 5G communication base station with humid and lightning-prone environment, equipped with 1 set of DC48V low-voltage DC distribution unit for base station equipment power supply.
  • Product Configuration: KITOZER Low Tier DC Distribution Unit (DC48V/100A), wall-mounted, IP40, Class B SPD and basic protection functions
  • Application Effect: Stable 2-year fault-free operation; SPD withstands mountain lightning surges without equipment damage; Wall-mounted design saves space with convenient installation, fitting narrow mountain base station equipment rooms

12. Common Faults & Maintenance

12.1 Common Faults & Solutions

12.1.1 Power Supply Faults

  • Fault Phenomenon: No input voltage, system fails to start Possible Causes: Tripped input circuit breaker, loose input cables, front-end power failure Solutions: Check and reset tripped input breaker; Tighten input terminal cables; Troubleshoot front-end power supply to restore power
  • Fault Phenomenon: Abnormal output voltage (Overvoltage / Undervoltage) Possible Causes: Faulty monitoring unit, abnormal rectifier module, poor bus contact Solutions: Restart and calibrate monitoring unit voltage parameters; Inspect and replace faulty rectifier modules; Tighten busbar terminals to reduce contact resistance

12.1.2 Protection Faults

  • Fault Phenomenon: Frequent circuit breaker tripping (Overload / Short-circuit) Possible Causes: Overloaded load, short-circuit on load side, aging circuit breaker Solutions: Calculate total load power and reduce redundant loads; Inspect load-side lines & equipment to eliminate short-circuits; Replace aging breakers with matched protection parameters
  • Fault Phenomenon: Insulation monitoring alarm Possible Causes: Reduced bus-to-ground insulation resistance, aged grounded cables, faulty load insulation Solutions: Disconnect branch loads one by one to locate faulty circuits; Replace aged insulated cables; Repair load insulation to restore normal insulation resistance

12.1.3 Monitoring & Communication Faults

  • Fault Phenomenon: No display on monitoring unit Possible Causes: Faulty monitoring power supply, damaged display screen, loose wiring Solutions: Inspect and replace monitoring unit power supply; Replace damaged screen; Tighten monitoring wiring terminals
  • Fault Phenomenon: Disconnected remote communication Possible Causes: Loose communication cables, faulty communication module, network failure Solutions: Tighten communication cable terminals; Restart or replace communication module; Troubleshoot network failure to restore connection

12.1.4 Lightning Protection & Heat Dissipation Faults

  • Fault Phenomenon: SPD failure alarm indicator Possible Causes: Aged SPD, lightning damage Solutions: Replace failed SPD; Regularly inspect SPD status with enhanced checks before thunderstorm seasons
  • Fault Phenomenon: Excess cabinet temperature, non-rotating fans Possible Causes: Faulty fan power supply, damaged fan, defective temperature control module Solutions: Inspect fan power supply and replace if faulty; Replace broken fans; Calibrate or replace temperature control module for normal heat dissipation

12.2 Daily Maintenance Schedule

12.2.1 Daily Maintenance

  1. Check monitoring unit data to confirm normal input/output voltage, current and temperature without alarms
  2. Inspect cabinet indicator lights: Running light steady on, no alarm light illuminated to verify normal equipment operation
  3. Listen for abnormal noise or burnt odor inside the cabinet; Shut down equipment for inspection immediately if anomalies detected

12.2.2 Weekly Maintenance

  1. Tighten all wiring terminals (Input/output, busbar, monitoring, communication) to prevent heating from loose connections
  2. Clean cabinet dust with dry brush or vacuum cleaner, focusing on cooling fans and vents to guarantee heat dissipation
  3. Inspect SPD status for no failure alarms and record SPD service time

12.2.3 Monthly Maintenance

  1. Calibrate voltage and current measurement accuracy of the monitoring unit to ensure accurate parameter display
  2. Test circuit breaker and isolator operating mechanisms with 1~2 manual switching cycles to confirm flexible operation without jamming
  3. Test insulation monitoring module, SPD and alarm module functions to ensure normal trigger of protection & alarms

12.2.4 Annual Maintenance

  1. Full inspection of cabinet, busbar and cable insulation; Replace aged and damaged components
  2. Lubricate circuit breaker and isolator operating mechanisms to extend mechanical service life
  3. Back up historical data and parameter configurations of the monitoring unit to prevent data loss
  4. Full system function test by simulating overload, short-circuit and insulation faults to verify protection reliability

13. Factory Strength & After-sales Service

13.1 Factory Strength

  • Production Scale: Modern manufacturing base covering 10,000㎡ with 5 standardized workshops, annual production capacity of 10,000 DC power distribution units to fulfill large batch orders
  • R&D Capacity: 50 professional R&D engineers including 15 senior engineers dedicated to DC power distribution technology innovation; Annual R&D investment accounts for 15% of revenue with 20 DC power distribution patents (5 invention patents), leading the industry in technical level
  • Production Process: Automated production lines equipped with laser cutting machines, CNC bending machines and automatic welding equipment; 80% automation rate for key processes; Strictly complies with ISO9001 Quality Management System, ISO14001 Environmental Management System and OHSAS18001 Occupational Health & Safety Management System for full-process quality control
  • Testing Equipment: High-precision calibration instruments (voltage/current calibrators, insulation resistance testers, short-circuit test equipment, environmental simulation chambers) deployed; Every unit undergoes 72-hour aging test and full-function inspection before delivery to ensure 100% qualified output
  • Supply Chain Advantages: Long-term strategic cooperation with well-known global component brands (Schneider, ABB, Siemens, Infineon) to supply genuine core components and guarantee stable product quality

13.2 After-sales Service

  • Warranty Commitment: 3-year free warranty for all products; Free repair and component replacement for non-human damage within warranty period; 5-year warranty for core components (monitoring unit, circuit breaker) of high tier products with lifetime maintenance
  • Technical Support: 7×24-hour technical hotline with professional engineers for online consultation and remote fault troubleshooting; Free technical training (equipment operation, maintenance, fault handling) via online and offline courses to ensure proficient equipment operation for customers
  • Installation & Commissioning: Free supply of installation drawings and wiring manuals; Professional engineers provide on-site installation & commissioning for large projects (≥5 units) to guarantee normal equipment commissioning
  • Rapid Response: Provide solutions within 2 hours upon fault report; Resolve general faults remotely within 4 hours; On-site support within 24 hours for major domestic faults to minimize customer losses
  • Customized Post-warranty Service: Preferential repair and component replacement services post-warranty; Support equipment upgrade (monitoring system upgrade, communication protocol upgrade, function expansion) to fit later capacity expansion and function upgrading demands of customers

14. Conclusion

As core equipment of new energy power distribution systems, KITOZER DC power distribution unit cabinets feature high reliability, full-dimensional safety protection, intelligent O&M, modular customization and high energy efficiency, fully adapting to DC power distribution demands of photovoltaic, wind power, energy storage, data center, communication and industrial control industries. The product portfolio covers low, medium and high configuration tiers, ranging from simple basic power distribution to full-intelligent high-voltage DC management, flexibly meeting diverse budget and functional requirements of different customers.

The factory boasts robust R&D, production and testing capabilities together with strict quality control systems to deliver reliable products. A comprehensive after-sales service system provides full-lifecycle protection including warranty commitments, technical support, installation commissioning and rapid response, eliminating customer worries.

In the future, KITOZER will continuously deepen innovation in DC power distribution technology, optimize product performance, expand product lines and upgrade service quality to facilitate efficient, safe and green development of the new energy industry, create greater value for customers and become the preferred brand in the new energy DC power distribution sector.

15. Search Keywords, SEO & Tags

15.1 Search Keywords

DC power distribution unit, DC power distribution cabinet, new energy DC power distribution, energy storage DC distribution unit, photovoltaic DC distribution cabinet, data center DC power distribution, DC48V DC cabinet, DC380V high-voltage DC power distribution, KITOZER DC distribution unit, intelligent DC distribution cabinet, industrial DC power distribution unit

15.2 SEO Optimization

  • Core Title: KITOZER DC Power Distribution Unit Cabinet – Special DC Power Distribution Equipment for New Energy Storage, Photovoltaic & Data Centers
  • Page Description: KITOZER provides professional new energy DC power distribution unit cabinets adapted to energy storage, photovoltaic, wind power, data center, communication and industrial control scenarios. Optional low/medium/high configurations with intelligent monitoring, reliable safety and customized services, direct supply from manufacturer with 3-year warranty.
  • Keyword Layout: Naturally embed core keywords such as “DC power distribution unit”, “DC distribution cabinet”, “new energy DC power distribution”, “energy storage DC distribution” in content with density controlled at 2%~5% without keyword stuffing
  • Internal Link Optimization: Link relevant pages inside the website including product details, solutions, application cases and technical parameters to improve page weight and user experience
  • External Link Construction: Exchange backlinks with high-quality new energy websites, energy storage platforms and data center forums to boost domain weight and keyword ranking

15.3 Tags

#DCPowerDistributionUnit #DCDistributionCabinet #NewEnergyDistribution #EnergyStorageEquipment #PhotovoltaicDistribution #DataCenterPowerSupply #IndustrialControl #KITOZER #IntelligentDistribution #HighVoltageDC

Shopping Cart