KITOZER
KITOZER

KITOZER BMS Building Equipment Management System Solution

Table of Contents

1. System Overview

KITOZER BMS Building Equipment Management System serves as the core hub of intelligent building integration. Built upon the Internet of Things, big data and automatic control technologies, it is designed for full-scenario buildings including commercial office buildings, industrial parks, data centers, hospitals and hotels. It functions as an integrated management platform to realize centralized monitoring, intelligent linkage, energy consumption optimization and efficient operation & maintenance of building electromechanical equipment.

Adopting the design philosophy of “Centralized Management, Decentralized Control”, the system seamlessly integrates HVAC, lighting, water supply & drainage, power supply & distribution, elevators, fire protection, security and other multi-system equipment. It breaks the information barriers of traditional isolated equipment operation and establishes a unified data interaction and control system.

As the “smart brain” of buildings, the KITOZER BMS system collects core data in real time, including temperature, humidity, COâ‚‚ concentration, energy consumption and equipment operating status. Intelligent algorithms automatically adjust equipment operating parameters to maximize energy savings and operation & maintenance costs while guaranteeing indoor environmental comfort and building safety, extend equipment service life, and help buildings achieve green, low-carbon and efficient operation goals.

The system supports dual modes of local monitoring and remote operation & maintenance, and is compatible with mainstream communication protocols such as BACnet, Modbus and KNX. Featuring high compatibility, stability and scalability, it can be flexibly configured according to building scale and demand, covering full-scenario applications from basic monitoring of small buildings to comprehensive management of large building clusters.

2. System Composition

The KITOZER BMS Building Equipment Management System adopts a three-layer distributed architecture: Perception Layer, Automatic Control Layer and Management Application Layer from bottom to top. Each layer operates independently while coordinating linkage to form a complete intelligent control system.

2.1 Perception Layer (Bottom Layer)

As the data collection and execution terminal of the system, it undertakes real-time collection of on-site environmental parameters and equipment operating status as well as execution of control commands, acting as the connecting link between the system and physical equipment.

  • Sensors: Temperature sensors, humidity sensors, COâ‚‚ sensors, air quality sensors, light sensors, human presence sensors, pressure sensors, flow sensors, energy consumption meters (electric meters, water meters, gas meters), etc.
  • Actuators: Electric regulating valves, air damper actuators, contactors, relays, intelligent switches, frequency converters, water pump controllers, fan controllers, etc.
  • I/O Modules: Analog Input (AI), Analog Output (AO), Digital Input (DI), Digital Output (DO) modules, realizing signal conversion and transmission between sensors, actuators and controllers.

2.2 Automatic Control Layer (Middle Layer)

The core control hub of the system, responsible for receiving data from the Perception Layer, conducting logical operation, data analysis and command issuance to realize automatic equipment control and linkage regulation.

  • Core Controllers: DDC Direct Digital Controllers, PLC Programmable Logic Controllers, with independent local control capability, non-loss data after power failure and support for free programming of control logic.
  • Communication Gateways: Protocol conversion gateways (BACnet/IP, Modbus RTU/TCP, KNX to Ethernet), edge computing gateways, realizing data interconnection and edge data processing of equipment with different protocols.
  • Network Devices: Industrial switches, optical fiber transceivers, wireless routers, building a stable on-site communication network and supporting multiple transmission modes including wired and wireless (4G/5G, LoRa, Wi-Fi).

2.3 Management Application Layer (Top Layer)

The human-computer interaction and centralized management platform of the system, responsible for data visualization, remote monitoring, parameter configuration, alarm management, data analysis and report generation, providing convenient management tools for operation & maintenance personnel.

  • Monitoring Hosts: Industrial control computers, servers equipped with system management software for data storage, operation and command issuance.
  • Human-Machine Interface (HMI): Touch screens, local operation panels for on-site monitoring and operation of equipment.
  • Remote Terminals: PC clients, tablet/mobile APPs supporting real-time remote monitoring, parameter adjustment, alarm reception and operation & maintenance management.
  • Data Storage & Analysis Devices: Hard disks, cloud storage, data analysis servers for historical data storage, energy consumption analysis, equipment operation trend analysis and report generation.

3. System Classification

The KITOZER BMS Building Equipment Management System can be classified from four dimensions: control scope, application scenario, functional positioning and deployment mode, meeting differentiated demands of various buildings.

3.1 Classification by Control Scope

  • Single Building BMS System: Suitable for single office buildings, shopping malls, hotels, etc., covering monitoring and management of all electromechanical equipment within the building, featuring simple architecture and convenient deployment.
  • Building Cluster BMS System: Suitable for industrial parks, commercial complexes, university campuses and other multi-building clusters, connecting individual BMS systems via network to realize centralized monitoring, unified management and data sharing.
  • Regional BMS System: Suitable for smart city zones and large industrial parks, integrating equipment data of multiple building clusters to realize cross-building and cross-system collaborative control and energy consumption optimization.

3.2 Classification by Application Scenario

  • Commercial Building BMS System: Adapted to office buildings, shopping centers and hotels, focusing on intelligent HVAC temperature control, energy-saving lighting control, refined energy consumption management and indoor comfort adjustment.
  • Data Center BMS System: Focused on data center computer rooms, core monitoring of precision air conditioners, UPS power supplies, power distribution cabinets and fire-fighting equipment to guarantee stable computer room temperature & humidity, continuous power supply and equipment safety.
  • Industrial Plant BMS System: Adapted to production workshops and industrial parks, focusing on monitoring of production auxiliary equipment, water supply & drainage, waste gas treatment, lighting and power distribution, balancing production safety and energy consumption optimization.
  • Hospital/Medical Building BMS System: Meeting demands of clean operating rooms, wards and inspection departments, strictly controlling temperature, humidity, cleanliness and pressure gradient to ensure safe medical environment and stable equipment operation.
  • Residential/Apartment BMS System: Adapted to high-end residences and apartment buildings, focusing on public area lighting, water supply & drainage, elevators and security monitoring, balancing resident comfort and property management convenience.

3.3 Classification by Functional Positioning

  • Basic Monitoring BMS System: Core functions include equipment status monitoring, parameter display and fault alarm without complex automatic control logic, suitable for small buildings and old building renovation with high cost performance.
  • Intelligent Control BMS System: Equipped with automatic control, logical linkage and energy consumption optimization functions, capable of automatically adjusting equipment operating status based on environmental parameters, suitable for medium and large buildings with remarkable energy-saving effects.
  • Comprehensive Management BMS System: Integrated with equipment monitoring, energy consumption analysis, operation & maintenance management, data analysis, report generation and remote operation & maintenance, supporting AI intelligent optimization and predictive maintenance, suitable for large building clusters and high-end commercial complexes.

3.4 Classification by Deployment Mode

  • Local Deployment BMS System: All hardware equipment, software systems and data storage deployed on-site in the building, featuring high data security and fast response speed, suitable for buildings with high data security requirements (government buildings, confidential sites, etc.).
  • Cloud Deployment BMS System: System software and data storage deployed on cloud servers, with only Perception Layer and Control Layer equipment deployed on-site and connected to the cloud via network, featuring low deployment cost and convenient remote operation & maintenance, suitable for distributed building clusters and small & medium-sized buildings.
  • Hybrid Deployment BMS System: Core control and data storage deployed locally, while non-core functions and remote management rely on the cloud, balancing data security and remote operation & maintenance advantages, suitable for medium and large complex buildings.

4. System Schematic Principle

The KITOZER BMS Building Equipment Management System follows the core working logic of “Perception & Collection → Transmission & Communication → Control & Operation → Application & Management”. Equipment of all layers are connected in order via communication networks to realize two-way data transmission and closed-loop command control.

4.1 Data Collection Process

Various sensors (temperature, humidity, COâ‚‚, etc.) of the Perception Layer collect real-time building environmental parameters and equipment operating status (water pump speed, fan frequency, valve opening, etc.). Analog or digital signals are converted into recognizable signals for controllers via I/O modules and transmitted to DDC/PLC controllers of the Automatic Control Layer.

4.2 Control & Operation Process

After receiving sensor data, DDC/PLC controllers compare data with preset parameter thresholds (e.g., set temperature 26℃, humidity 50%) and conduct operation analysis through built-in control logic (PID regulation, sequence control, linkage logic) to generate control commands. If data exceeds thresholds (e.g., temperature higher than 28℃), controllers issue commands to actuators (turn on air conditioners, increase fan speed, etc.) to realize automatic equipment adjustment.

4.3 Data Transmission & Storage Process

Controllers upload raw collected data, equipment operating status data and alarm data to monitoring hosts/servers of the Management Application Layer via industrial switches and communication gateways. Servers classify, organize, store and back up data while supporting cloud synchronization to ensure traceable and secure data.

4.4 Monitoring & Operation Process

Operation & maintenance personnel view real-time system data, equipment operating status and environmental parameters through PC clients, touch screens, mobile APPs and other terminals of the Management Application Layer. They can manually issue control commands (remotely turn on lighting, adjust air conditioner temperature, etc.) or set automatic control strategies for autonomous system operation. When equipment fails or parameters are abnormal, the system triggers sound-light alarms and pushes alarm information via SMS/APP to remind operation & maintenance personnel of timely handling.

4.5 System Linkage Principle

The system supports cross-equipment and cross-subsystem linkage control. For example: when the fire protection system triggers a fire alarm, the BMS system automatically shuts down air conditioners, cuts off non-fire-fighting power supplies, turns on emergency lighting and smoke exhaust fans; when human presence sensors detect unoccupied rooms, it automatically turns off lighting and reduces air conditioner wind speed to realize energy-saving linkage.

5. Full System Configuration List (Low/Mid/High-End Versions, KITOZER Brand)

5.1 Low-End Version Configuration List (Small Buildings / Basic Monitoring, ≤5,000 ㎡)

表格

No.Product NameModelTechnical ParametersQty.UnitBrandRemarks
1BMS Monitoring HostKITOZER-BMS-H1Industrial grade, i5 CPU, 8G RAM, 256G SSD, Windows 10, including basic monitoring software1SetKITOZERLocal deployment, supports monitoring within 100 points
2DDC ControllerKITOZER-DDC-1088AI/4AO/8DI/4DO, Modbus protocol, DC24V power supply, built-in LCD display2SetKITOZEROn-site control, 24 I/O points per unit
3Temperature SensorKITOZER-S-T10Measuring range: -30℃~+50℃, accuracy ±0.5℃, 4-20mA output, DC24V power supply15PcsKITOZERIndoor/air duct temperature detection
4Humidity SensorKITOZER-S-H10Measuring range: 0~100%RH, accuracy ±3%RH, 4-20mA output, DC24V power supply10PcsKITOZERIndoor/air duct humidity detection
5Light SensorKITOZER-S-L10Measuring range: 0~10,000lux, accuracy ±5%, 4-20mA output, DC24V power supply8PcsKITOZERPublic area light detection
6Human Presence SensorKITOZER-S-P10Microwave + infrared dual detection, detection distance 8m, 120° sensing angle, dry contact output, DC24V power supply12PcsKITOZEROffice/corridor human detection
7Analog Input ModuleKITOZER-I-O-AI1616-channel AI, supports 4-20mA/0-10V input, Modbus protocol, DC24V power supply1SetKITOZERExpand analog collection points
8Digital Output ModuleKITOZER-I-O-DO1616-channel DO, relay output, contact capacity AC220V/5A, Modbus protocol, DC24V power supply1SetKITOZERExpand switch control points
9Industrial SwitchKITOZER-SW-5P5-port 100M unmanaged switch, 4-port POE, DC24V power supply2SetKITOZEROn-site equipment network connection
10Communication GatewayKITOZER-GW-MBModbus RTU to TCP, supports 10 slave stations, DC24V power supply, metal housing1SetKITOZERProtocol conversion, data upload
11Touch Screen HMIKITOZER-HMI-707-inch, 800×480 resolution, Modbus protocol, DC24V power supply, embedded installation1SetKITOZERLocal monitoring & operation
12Sound-Light AlarmKITOZER-ALM-S10Red LED flashing, alarm volume ≥110dB, DC24V power supply, wall-mounted2SetKITOZEROn-site fault alarm prompt
13System Management Software (Low-End)KITOZER-BMS-SOFT-LSupports 100-point monitoring, real-time data display, fault alarm, historical data query, simple report generation1SetKITOZERIncludes 1-year free upgrade

5.2 Mid-End Version Configuration List (Medium Buildings / Intelligent Control, 5,000-20,000 ㎡)

表格

No.Product NameModelTechnical ParametersQty.UnitBrandRemarks
1BMS Monitoring ServerKITOZER-BMS-S2Enterprise grade, i7 CPU, 16G RAM, 512G SSD + 2T HDD, Windows Server 2019, intelligent control software included1SetKITOZERLocal/cloud deployment, supports monitoring within 500 points
2DDC ControllerKITOZER-DDC-21616AI/8AO/16DI/8DO, BACnet/Modbus dual protocol, DC24V power supply, built-in LCD + operation buttons5SetKITOZEROn-site control, 48 I/O points per unit
3PLC ControllerKITOZER-PLC-30032 I/O channels, supports PID regulation & logical programming, compliant with IEC 61131-3, DC24V power supply2SetKITOZERComplex equipment linkage control
4Temperature SensorKITOZER-S-T20Measuring range: -40℃~+80℃, accuracy ±0.3℃, optional 4-20mA/0-10V output, DC24V power supply, waterproof30PcsKITOZERIndoor/air duct/water pipe temperature detection
5Humidity SensorKITOZER-S-H20Measuring range: 0~100%RH, accuracy ±2%RH, optional 4-20mA/0-10V output, DC24V power supply, dustproof20PcsKITOZERIndoor/air duct/computer room humidity detection
6CO₂ SensorKITOZER-S-C20Measuring range: 0~5,000ppm, accuracy ±50ppm, 4-20mA output, DC24V power supply, NDIR infrared detection15PcsKITOZERIndoor air quality detection
7Air Quality SensorKITOZER-S-A20Detects PM2.5/PM10/VOC, accuracy ±10%, 4-20mA output, DC24V power supply12PcsKITOZERPublic area air quality monitoring
8Pressure SensorKITOZER-S-P20Measuring range: 0~1.6MPa, accuracy ±0.5%FS, 4-20mA output, DC24V power supply, stainless steel material10PcsKITOZERWater pipe/air duct pressure detection
9Flow SensorKITOZER-S-F20Measuring range: 0~100m³/h, accuracy ±1.0%FS, 4-20mA output, DC24V power supply, turbine type8PcsKITOZERWater supply & drainage flow detection
10Energy MeterKITOZER-M-E20Three-phase four-wire, Class 0.5S accuracy, measures voltage/current/power/electric energy, Modbus protocol, AC380V power supply15PcsKITOZERSub-item energy consumption metering
11Electric Regulating ValveKITOZER-V-E20DN25 2-way modulating type, 4-20mA input, AC220V power supply, brass valve body12SetKITOZERAir conditioning water system flow regulation
12Air Damper ActuatorKITOZER-A-D2010Nm torque, modulating type, 4-20mA input, AC220V power supply, IP54 protection grade10SetKITOZERAir conditioning damper opening control
13I/O Expansion ModuleKITOZER-I-O-EX3232 mixed I/O (16AI+16DI), BACnet/Modbus protocol, DC24V power supply4SetKITOZERExpand monitoring points
14Industrial SwitchKITOZER-SW-8P8-port 100M managed switch, 6-port POE, DC24V power supply, supports VLAN division4SetKITOZEROn-site equipment network connection & management
15Edge Computing GatewayKITOZER-GW-EDGE2Supports BACnet/Modbus/KNX protocol conversion, edge data processing, 4G/5G networking, DC24V power supply2SetKITOZERMulti-protocol equipment access, data preprocessing
16Touch Screen HMIKITOZER-HMI-10010-inch, 1280×800 resolution, BACnet/Modbus protocol, DC24V power supply, wall-mounted2SetKITOZERLocal monitoring & operation, multi-screen switching supported
17Remote Operation & Maintenance TabletKITOZER-PAD-1010-inch Android tablet, 4G networking, supports BMS APP remote monitoring1SetKITOZERMobile remote operation & maintenance
18Sound-Light AlarmKITOZER-ALM-S20Red-blue dual-color flashing, alarm volume ≥120dB, DC24V power supply, waterproof & dustproof4SetKITOZEROn-site fault alarm prompt
19UPS Power SupplyKITOZER-UPS-1K1KVA online type, backup time ≥30min, AC220V input/output2SetKITOZERUninterrupted power supply for monitoring equipment
20System Management Software (Mid-End)KITOZER-BMS-SOFT-MSupports 500-point monitoring, real-time data visualization, intelligent control strategy configuration, energy consumption analysis, classified alarm management, 1-year historical data storage, automatic report generation1SetKITOZERIncludes 3-year free upgrade & technical support

5.3 High-End Version Configuration List (Large Buildings / Comprehensive Management, ≥20,000 ㎡ / Building Clusters)

表格

No.Product NameModelTechnical ParametersQty.UnitBrandRemarks
1Redundant BMS Monitoring ServerKITOZER-BMS-S4Dual hot standby, i9 CPU, 32G DDR5 RAM, 1T SSD + 4T HDD, Windows Server 2022, comprehensive management software included2SetKITOZERLocal/cloud deployment, supports monitoring within 2,000 points
2DDC ControllerKITOZER-DDC-43232AI/16AO/32DI/16DO, supports BACnet/IP, Modbus TCP, KNX, DC24V power supply, built-in LCD & Ethernet port10SetKITOZEROn-site control, 96 I/O points per unit
3PLC ControllerKITOZER-PLC-50064 I/O channels, supports PID/fuzzy control & logical programming, compliant with IEC 61131-3, DC24V power supply, dual Ethernet ports (redundant)5SetKITOZERComplex equipment linkage & logic control
4Temperature SensorKITOZER-S-T30Measuring range: -50℃~+100℃, accuracy ±0.1℃, optional 4-20mA/0-10V output, DC24V power supply, high-precision waterproof80PcsKITOZERIndoor/air duct/water pipe/computer room temperature detection
5Humidity SensorKITOZER-S-H30Measuring range: 0~100%RH, accuracy ±1%RH, optional 4-20mA/0-10V output, DC24V power supply, high-precision waterproof & dustproof50PcsKITOZERIndoor/air duct/computer room/clean room humidity detection
6CO₂ SensorKITOZER-S-C30Measuring range: 0~10,000ppm, accuracy ±30ppm, 4-20mA output, DC24V power supply, NDIR infrared + temperature & humidity compensation30PcsKITOZERIndoor/public area air quality detection
7Air Quality SensorKITOZER-S-A30Detects PM2.5/PM10/VOC/formaldehyde, accuracy ±5%, 4-20mA output, DC24V power supply, with AQI display25PcsKITOZERPublic area/computer room air quality monitoring
8Pressure SensorKITOZER-S-P30Measuring range: 0~2.5MPa, accuracy ±0.2%FS, 4-20mA output, DC24V power supply, 316 stainless steel, high temperature resistant20PcsKITOZERWater pipe/air duct/air conditioning system pressure detection
9Flow SensorKITOZER-S-F30Measuring range: 0~200m³/h, accuracy ±0.5%FS, 4-20mA output, DC24V power supply, electromagnetic anti-corrosion type15PcsKITOZERWater supply & drainage/air conditioning water flow detection
10Energy MeterKITOZER-M-E30Three-phase four-wire, Class 0.2S accuracy, measures voltage/current/power/electric energy/harmonics, Modbus TCP, AC380V power supply, remote meter reading30PcsKITOZERRefined sub-item/zonal energy consumption metering
11Water MeterKITOZER-M-W30DN50, pulse/Modbus protocol, accuracy ±0.5%, DC24V power supply, waterproof20PcsKITOZERWater supply & drainage energy consumption metering
12Electric Regulating ValveKITOZER-V-E30DN50 3-way modulating type, 4-20mA input, AC220V power supply, stainless steel valve body with position feedback25SetKITOZERAir conditioning water/hot water system flow regulation
13Air Damper ActuatorKITOZER-A-D3020Nm torque, modulating type, 4-20mA input, AC220V power supply, IP65 protection grade with position feedback20SetKITOZERAir conditioning damper/smoke exhaust damper opening control
14I/O Expansion ModuleKITOZER-I-O-EX6464 mixed I/O (32AI+32DI), BACnet/IP/Modbus TCP protocol, DC24V power supply, hot-swappable8SetKITOZERExpand monitoring points, hot swap supported
15Industrial SwitchKITOZER-SW-16P16-port Gigabit managed switch, 12-port POE, DC24V power supply, supports VLAN/link aggregation/ring network redundancy8SetKITOZEROn-site equipment network connection with redundancy
16Core SwitchKITOZER-SW-C2424-port Gigabit Layer 3 managed switch, supports routing protocol/ACL/port mirroring, AC220V power supply2SetKITOZERSystem core network switching
17Edge Computing GatewayKITOZER-GW-EDGE4Supports BACnet/IP, Modbus TCP, KNX, OPC UA protocol conversion, edge AI computing, 5G/fiber networking, DC24V power supply, redundant design4SetKITOZERMulti-protocol equipment access, AI data preprocessing
18Touch Screen HMIKITOZER-HMI-15015-inch, 1920×1080 resolution, BACnet/IP/Modbus TCP protocol, DC24V power supply, embedded high-definition display4SetKITOZERLocal monitoring & operation, multi-screen linkage supported
19Remote Operation & Maintenance SuiteKITOZER-PRO-SET12-inch dual-system tablet (Android + Windows) + industrial laptop, 5G networking, supports BMS APP/client remote monitoring3SetKITOZERMobile remote operation & maintenance + professional maintenance
20Sound-Light AlarmKITOZER-ALM-S303-color (red/yellow/green) flashing, alarm volume ≥130dB, DC24V power supply, waterproof, dustproof & explosion-proof8SetKITOZEROn-site fault/warning/normal status prompt
21Redundant UPS Power SupplyKITOZER-UPS-3K3KVA online type, dual-machine redundancy, backup time ≥60min, AC220V input/output with battery management4SetKITOZERRedundant uninterrupted power supply for monitoring equipment
22Data Storage SSDKITOZER-SSD-4T4T enterprise solid state drive, read-write speed ≥500MB/s, shockproof & drop-resistant4PcsKITOZERHistorical data storage (over 5 years)
23System Management Software (High-End)KITOZER-BMS-SOFT-HSupports 2,000-point monitoring, real-time 3D data visualization, AI intelligent control strategy, energy consumption analysis & optimization, predictive maintenance, intelligent classified alarm, permanent historical data storage, automatic report generation & push, multi-system integration (fire protection/security/elevator), cloud remote operation & maintenance1SetKITOZERIncludes 5-year free upgrade & 7×24-hour technical support

6. Full Product Technical Specifications

6.1 Monitoring Host / Server Series

  • KITOZER-BMS-H1 (Low-End Monitoring Host): Industrial chassis; i5-10400 CPU; 8GB DDR4 RAM; 256GB SSD storage; Windows 10 64-bit OS; 4×USB3.0, 1×Ethernet, 2×serial ports; operating temperature 0℃~50℃; AC220V power supply.
  • KITOZER-BMS-S2 (Mid-End Monitoring Server): Enterprise chassis; i7-11700 CPU; 16GB DDR4 RAM; 512GB SSD + 2TB HDD storage; Windows Server 2019 OS; 6×USB3.0, 2×Gigabit Ethernet, 4×serial ports; operating temperature -10℃~55℃; AC220V power supply.
  • KITOZER-BMS-S4 (High-End Monitoring Server): Redundant design; i9-12900 CPU; 32GB DDR5 RAM; 1TB SSD + 4TB HDD storage; Windows Server 2022 OS; 8×USB3.0, 2×10G Ethernet, 4×Gigabit Ethernet, 8×serial ports; operating temperature -20℃~60℃; AC220V dual redundant power supply.

6.2 DDC / PLC Controller Series

  • KITOZER-DDC-108 (Low-End DDC): I/O allocation 8AI/4AO/8DI/4DO; Modbus RTU communication; DC24V±10% power supply; operating temperature -30℃~60℃; IP30 protection grade; built-in 128×64 LCD display, supports local programming.
  • KITOZER-DDC-216 (Mid-End DDC): I/O allocation 16AI/8AO/16DI/8DO; BACnet/Modbus RTU/TCP dual protocol; DC24V±10% power supply; operating temperature -40℃~70℃; IP40 protection grade; built-in LCD + operation buttons, supports PID regulation.
  • KITOZER-DDC-432 (High-End DDC): I/O allocation 32AI/16AO/32DI/16DO; BACnet/IP, Modbus TCP, KNX protocols; DC24V±10% power supply; operating temperature -50℃~80℃; IP50 protection grade; built-in LCD + Ethernet port, supports fuzzy control.
  • KITOZER-PLC-300 (Mid-End PLC): 32 I/O channels (expandable to 128); Modbus RTU/TCP communication; IEC 61131-3 programming standard; DC24V power supply; operating temperature -20℃~60℃; supports PID/logic/sequence control, built-in Ethernet port.
  • KITOZER-PLC-500 (High-End PLC): 64 I/O channels (expandable to 256); BACnet/IP, Modbus TCP, OPC UA communication; IEC 61131-3 programming standard; DC24V dual redundant power supply; operating temperature -30℃~70℃; supports PID/fuzzy/adaptive control, dual redundant Ethernet ports.

6.3 Sensor Series

Temperature Sensors (KITOZER-S-T10/T20/T30)

  • T10: -30℃~+50℃, accuracy ±0.5℃, 4-20mA output, DC24V, IP30.
  • T20: -40℃~+80℃, accuracy ±0.3℃, optional 4-20mA/0-10V output, DC24V, IP54 waterproof.
  • T30: -50℃~+100℃, accuracy ±0.1℃, optional 4-20mA/0-10V output, DC24V, IP65 high-precision waterproof.

Humidity Sensors (KITOZER-S-H10/H20/H30)

  • H10: 0~100%RH, accuracy ±3%RH, 4-20mA output, DC24V, IP30.
  • H20: 0~100%RH, accuracy ±2%RH, optional 4-20mA/0-10V output, DC24V, IP54 dustproof.
  • H30: 0~100%RH, accuracy ±1%RH, optional 4-20mA/0-10V output, DC24V, IP65 high-precision waterproof & dustproof.

COâ‚‚ Sensors (KITOZER-S-C20/C30)

  • C20: 0~5,000ppm, accuracy ±50ppm, 4-20mA output, DC24V, NDIR detection, IP40.
  • C30: 0~10,000ppm, accuracy ±30ppm, 4-20mA output, DC24V, NDIR + temperature & humidity compensation, IP54.

Air Quality Sensors (KITOZER-S-A20/A30)

  • A20: Detects PM2.5/PM10/VOC, accuracy ±10%, 4-20mA output, DC24V, IP40.
  • A30: Detects PM2.5/PM10/VOC/formaldehyde, accuracy ±5%, 4-20mA output, DC24V with display screen, IP54.

Pressure Sensors (KITOZER-S-P20/P30)

  • P20: 0~1.6MPa, accuracy ±0.5%FS, 4-20mA output, DC24V, brass material, IP54.
  • P30: 0~2.5MPa, accuracy ±0.2%FS, 4-20mA output, DC24V, 316 stainless steel, IP65 high temperature resistant.

Flow Sensors (KITOZER-S-F20/F30)

  • F20: 0~100m³/h, accuracy ±1.0%FS, 4-20mA output, DC24V, turbine type, IP54.
  • F30: 0~200m³/h, accuracy ±0.5%FS, 4-20mA output, DC24V, electromagnetic anti-corrosion type, IP65.

Human Presence Sensor (KITOZER-S-P10)

Microwave + infrared dual detection; detection distance 8m; 120° sensing angle; dry contact (NO/NC) output; DC24V power supply; operating temperature -20℃~60℃; IP40.

Light Sensor (KITOZER-S-L10)

0~10,000lux; accuracy ±5%; 4-20mA output; DC24V power supply; operating temperature -30℃~50℃; IP30.

6.4 Actuator & Meter Series

Electric Regulating Valves (KITOZER-V-E20/E30)

  • E20: DN25 2-way modulating type, 4-20mA input, AC220V power supply, brass valve body, IP54.
  • E30: DN50 3-way modulating type, 4-20mA input, AC220V power supply, stainless steel valve body with position feedback, IP65.

Air Damper Actuators (KITOZER-A-D20/D30)

  • D20: 10Nm torque, modulating type, 4-20mA input, AC220V power supply, IP54.
  • D30: 20Nm torque, modulating type, 4-20mA input, AC220V power supply with position feedback, IP65.

Energy Meters (KITOZER-M-E20/E30)

  • E20: Three-phase four-wire, Class 0.5S accuracy, measures voltage/current/power/electric energy, Modbus RTU, AC380V, IP54.
  • E30: Three-phase four-wire, Class 0.2S accuracy, measures voltage/current/power/electric energy/harmonics, Modbus TCP, AC380V, remote meter reading, IP54.

Water Meter (KITOZER-M-W30)

DN50, pulse/Modbus protocol, accuracy ±0.5%, DC24V power supply, waterproof, IP65.

6.5 Communication & Network Equipment Series

Industrial Switches (KITOZER-SW-5P/8P/16P)

  • 5P: 5-port 100M unmanaged switch, 4-port POE (DC24V), IP30.
  • 8P: 8-port 100M managed switch, 6-port POE (DC24V), supports VLAN, IP40.
  • 16P: 16-port Gigabit managed switch, 12-port POE (DC24V), supports VLAN/ring network redundancy, IP50.

Core Switch (KITOZER-SW-C24)

24-port Gigabit Layer 3 managed switch, supports static routing/OSPF/ACL/port mirroring, AC220V, IP40.

Communication Gateway (KITOZER-GW-MB)

Modbus RTU to TCP, supports 10 slave stations, DC24V power supply, metal housing, IP40.

Edge Computing Gateways (KITOZER-GW-EDGE2/EDGE4)

  • EDGE2: BACnet/Modbus/KNX protocol conversion, edge data processing, 4G/5G networking, DC24V, IP50.
  • EDGE4: BACnet/IP/Modbus TCP/KNX/OPC UA protocol conversion, edge AI computing, 5G/fiber networking, redundant design, DC24V, IP65.

6.6 HMI & Auxiliary Equipment Series

Touch Screens (KITOZER-HMI-70/100/150)

  • 70: 7-inch, 800×480 resolution, Modbus, DC24V, IP54.
  • 100: 10-inch, 1280×800 resolution, BACnet/Modbus, DC24V, IP54.
  • 150: 15-inch, 1920×1080 resolution, BACnet/IP/Modbus TCP, DC24V, IP65 embedded high-definition display.

Sound-Light Alarms (KITOZER-ALM-S10/S20/S30)

  • S10: Red flashing, 110dB volume, DC24V, IP30.
  • S20: Red-blue flashing, 120dB volume, DC24V, waterproof & dustproof, IP54.
  • S30: 3-color flashing, 130dB volume, DC24V, waterproof, dustproof & explosion-proof, IP65.

UPS Power Supplies (KITOZER-UPS-1K/3K)

  • 1K: 1KVA online type, 30min backup time, AC220V input/output, IP40.
  • 3K: 3KVA online type, dual-machine redundancy, 60min backup time, AC220V input/output with battery management, IP50.

I/O Expansion Modules (KITOZER-I-O-EX32/EX64)

  • EX32: 32 mixed I/O (16AI+16DI), BACnet/Modbus, DC24V, IP40.
  • EX64: 64 mixed I/O (32AI+32DI), BACnet/IP/Modbus TCP, hot-swappable, DC24V, IP50.

6.7 System Management Software Series

  • KITOZER-BMS-SOFT-L (Low-End): Supports 100-point monitoring; real-time data display; sound-light & pop-up fault alarm; 6-month historical data query; simple daily/monthly report generation; local deployment, Windows compatible.
  • KITOZER-BMS-SOFT-M (Mid-End): Supports 500-point monitoring; chart/curve real-time data visualization; intelligent control strategy configuration (sequence/linkage/PID); sub-item/zonal energy consumption analysis; classified alarm management (warning/general/severe); 1-year historical data storage; automatic report generation & export; local/cloud deployment, Windows compatible.
  • KITOZER-BMS-SOFT-H (High-End): Supports 2,000-point monitoring; 2D/3D real-time visualization; AI intelligent control algorithm; energy consumption analysis & optimization (energy-saving reports); predictive equipment maintenance & health assessment; intelligent classified alarm + APP push; permanent historical data storage; automatic report generation & push; multi-system integration (fire protection/security/elevator); cloud remote operation & maintenance; Windows/Linux compatible.

7. Full Product Application Scope

7.1 Monitoring Host / Server Series

  • KITOZER-BMS-H1: Small office buildings, apartments, shops, small factories (≤5,000 ㎡), basic monitoring scenarios.
  • KITOZER-BMS-S2: Medium commercial buildings, hotels, hospitals, industrial parks (5,000-20,000 ㎡), intelligent control scenarios.
  • KITOZER-BMS-S4: Large commercial complexes, data centers, university campuses, large hospitals (≥20,000 ㎡), comprehensive management & building cluster control scenarios.

7.2 DDC / PLC Controller Series

  • KITOZER-DDC-108: Basic control of HVAC, lighting and water supply & drainage for small buildings.
  • KITOZER-DDC-216: Linkage control of HVAC, lighting, water supply & drainage and elevators for medium buildings.
  • KITOZER-DDC-432: Precise control of HVAC, chilled water, ventilation and smoke exhaust systems for large buildings/clusters.
  • KITOZER-PLC-300: Linkage control of production auxiliary equipment and complex electromechanical equipment for medium factories.
  • KITOZER-PLC-500: High-precision & high-reliability equipment control for large factories, data centers and medical buildings.

7.3 Sensor Series

  • Temperature/Humidity Sensors: Indoor environment, air ducts, water pipes, computer rooms, clean rooms and warehouse temperature & humidity monitoring.
  • COâ‚‚/Air Quality Sensors: Air quality monitoring for offices, meeting rooms, shopping mall lobbies, underground parking lots and computer rooms.
  • Pressure/Flow Sensors: Pressure & flow monitoring of air conditioning water, water supply & drainage, gas pipelines and ventilation ducts.
  • Human Presence/Light Sensors: Intelligent lighting control for office areas, corridors, stairwells and public restrooms.

7.4 Actuator & Meter Series

  • Electric Regulating Valves / Air Damper Actuators: Flow regulation of air conditioning water systems, air damper opening control and smoke exhaust valve linkage control.
  • Energy Meters / Water Meters: Sub-item & zonal energy consumption metering, energy-saving analysis and energy billing for buildings.

7.5 Communication & Network Equipment Series

  • Industrial Switches / Core Switches: On-site equipment networking, core data exchange and network redundant backup for BMS systems.
  • Communication Gateways / Edge Computing Gateways: Access of multi-protocol equipment, data conversion, edge data processing and cloud data upload.

7.6 HMI & Auxiliary Equipment Series

  • Touch Screens: Local monitoring & operation in computer rooms and equipment rooms.
  • Sound-Light Alarms: Prompting equipment faults and abnormal parameters.
  • UPS Power Supplies: Uninterrupted power supply for core equipment including monitoring hosts, servers, controllers and gateways.
  • I/O Expansion Modules: Expand monitoring points and access newly added equipment.

7.7 System Management Software Series

  • KITOZER-BMS-SOFT-L: Basic monitoring, data query and alarm management for small buildings.
  • KITOZER-BMS-SOFT-M: Intelligent control, energy consumption analysis and report management for medium buildings.
  • KITOZER-BMS-SOFT-H: Comprehensive management, AI optimization, predictive maintenance and multi-system integration for large buildings/clusters.

8. Full Product Advantages

8.1 Core Brand Advantages

As a professional brand in the intelligent building industry, KITOZER has over ten years of R&D and production experience in BMS systems. It owns an independent R&D team, modern production plant, complete quality control system and professional technical service team. The full range of building equipment monitoring products support customized development, OEM/ODM processing and confidential technical services with sufficient spot inventory and short delivery cycles to rapidly respond to customer demands.

8.2 Monitoring Host / Server Advantages

  • KITOZER-BMS-H1: Industrial design with strong stability; compact size for easy installation; high cost performance to meet basic demands of small buildings.
  • KITOZER-BMS-S2: Enterprise-grade configuration with fast computing speed; large storage capacity supporting long-term data storage; rich interfaces and strong scalability.
  • KITOZER-BMS-S4: Dual redundant design eliminating single-point failure; high-performance hardware supporting 3D visualization and AI computing; 7×24-hour uninterrupted operation with ultra-high reliability.

8.3 DDC / PLC Controller Advantages

  • Full-series controllers support mainstream protocols including BACnet/IP, Modbus TCP, KNX and OPC UA with strong compatibility to connect third-party equipment.
  • High stability: Wide operating temperature range (-50℃~80℃), dustproof & waterproof design adapting to harsh industrial environments; no data loss after power failure for stable operation.
  • Flexible programming: Supports free programming, PID regulation, fuzzy control and logical linkage to customize control strategies per customer demands.
  • Strong scalability: Supports I/O module expansion to flexibly increase monitoring points for buildings of all scales.

8.4 Sensor Advantages

  • High precision: Temperature accuracy up to ±0.1℃, humidity ±1%RH, COâ‚‚ ±30ppm, meeting precise monitoring demands of all building types.
  • High stability: Imported sensing chips with strong anti-interference capability, low long-term drift and service life ≥5 years.
  • High protection grade: Maximum IP65 waterproof & dustproof rating adapting to humid, dusty and high-temperature harsh environments.
  • Easy installation: Multiple mounting methods (wall-mounted, air duct, water pipe) with simple wiring and convenient debugging.

8.5 Actuator & Meter Advantages

  • Electric Regulating Valves: Corrosion-resistant stainless steel/brass valve bodies, high regulation accuracy and fast response with position feedback for precise control.
  • Air Damper Actuators: High torque design with stable operation, IP65 protection grade adapting to harsh environments, supporting proportional regulation and accurate linkage.
  • Energy Meters: High-precision Class 0.2S metering with accurate data; supports remote meter reading eliminating manual inspection; waterproof & dustproof with long service life.

8.6 Communication & Network Equipment Advantages

  • Industrial Switches: Wide temperature design adapting to harsh environments; POE power supply simplifying wiring; supports VLAN division and ring network redundancy for stable networks.
  • Edge Computing Gateways: Multi-protocol conversion with strong compatibility; edge AI computing reducing server load; supports 4G/5G/fiber networking for convenient remote operation & maintenance.

8.7 HMI & Auxiliary Equipment Advantages

  • Touch Screens: High-definition display with intuitive simple operation interface; multi-language support for diverse scenarios; high protection grade adapting to harsh environments.
  • UPS Power Supplies: Online design with stable voltage regulation; long backup time guaranteeing uninterrupted equipment operation; redundant design for high reliability.
  • I/O Expansion Modules: Hot-swappable design enabling expansion without power cut; high compatibility matching full-series controllers with easy installation and debugging.

8.8 System Management Software Advantages

  • Visual Interface: Supports 2D/3D visualization to intuitively display equipment status and environmental parameters.
  • Intelligent Control: Built-in AI intelligent algorithms automatically optimize equipment operating parameters with energy-saving rate of 15%-30%.
  • Energy Consumption Analysis: Refined energy consumption statistics & analysis generating energy-saving reports to support green low-carbon building operation.
  • Predictive Maintenance: Real-time equipment operation monitoring for early fault warning, reducing operation & maintenance costs and extending equipment service life.
  • Remote Operation & Maintenance: Supports PC/tablet/mobile APP remote monitoring & operation for all-time building equipment management.
  • Multi-System Integration: Seamlessly connects fire protection, security, elevator, power supply & distribution systems to realize comprehensive intelligent building management.

8.9 Customization & Service Advantages

  • Customized Development: Custom hardware and software systems based on building characteristics and functional demands to meet personalized requirements.
  • OEM/ODM Processing: Supports OEM/ODM production with confidential technical services to protect customer intellectual property rights.
  • Spot Supply: Full-series products stocked in large quantities with short delivery cycles (3-7 days) for rapid project response.
  • Technical Support: 7×24-hour technical support, free installation & commissioning, operation training and software upgrade to guarantee stable system operation throughout the lifecycle.

9. Product Bid Specification Parameters (Marked with ★)

9.1 Monitoring Host / Server

KITOZER-BMS-H1

  • ★CPU: i5-10400 or higher
  • ★RAM: ≥8GB DDR4
  • ★Storage: ≥256GB SSD
  • ★Interfaces: ≥4×USB3.0, ≥1×Gigabit Ethernet port
  • ★Operating Temperature: 0℃~50℃

KITOZER-BMS-S2

  • ★CPU: i7-11700 or higher
  • ★RAM: ≥16GB DDR4
  • ★Storage: ≥512GB SSD + 2TB HDD
  • ★Interfaces: ≥6×USB3.0, ≥2×Gigabit Ethernet, ≥4×serial ports
  • ★Operating Temperature: -10℃~55℃

KITOZER-BMS-S4

  • ★Architecture: Dual hot standby redundant design
  • ★CPU: i9-12900 or higher
  • ★RAM: ≥32GB DDR5
  • ★Storage: ≥1TB SSD + 4TB HDD
  • ★Interfaces: ≥2×10G Ethernet, ≥4×Gigabit Ethernet
  • ★Operating Temperature: -20℃~60℃

9.2 DDC Controller

KITOZER-DDC-108

  • ★I/O Allocation: ≥8AI/4AO/8DI/4DO
  • ★Communication Protocol: Supports Modbus RTU
  • ★Power Supply: DC24V±10%
  • ★Operating Temperature: -30℃~60℃

KITOZER-DDC-216

  • ★I/O Allocation: ≥16AI/8AO/16DI/8DO
  • ★Communication Protocol: Supports BACnet/Modbus RTU/TCP
  • ★Power Supply: DC24V±10%
  • ★Operating Temperature: -40℃~70℃

KITOZER-DDC-432

  • ★I/O Allocation: ≥32AI/16AO/32DI/16DO
  • ★Communication Protocol: Supports BACnet/IP, Modbus TCP, KNX
  • ★Power Supply: DC24V±10%
  • ★Operating Temperature: -50℃~80℃

9.3 PLC Controller

KITOZER-PLC-300

  • ★I/O Allocation: ≥32 channels (expandable to 128)
  • ★Communication Protocol: Supports Modbus RTU/TCP
  • ★Programming Standard: IEC 61131-3
  • ★Power Supply: DC24V

KITOZER-PLC-500

  • ★I/O Allocation: ≥64 channels (expandable to 256)
  • ★Communication Protocol: Supports BACnet/IP, Modbus TCP, OPC UA
  • ★Programming Standard: IEC 61131-3
  • ★Power Supply: DC24V dual redundant power supply

9.4 Sensors

High-Precision Temperature Sensor (KITOZER-S-T30)

  • ★Measuring Range: -50℃~+100℃
  • ★Accuracy: ±0.1℃
  • ★Output Signal: Optional 4-20mA/0-10V
  • ★Protection Grade: IP65

High-Precision Humidity Sensor (KITOZER-S-H30)

  • ★Measuring Range: 0~100%RH
  • ★Accuracy: ±1%RH
  • ★Output Signal: Optional 4-20mA/0-10V
  • ★Protection Grade: IP65

COâ‚‚ Sensor (KITOZER-S-C30)

  • ★Measuring Range: 0~10,000ppm
  • ★Accuracy: ±30ppm
  • ★Detection Principle: NDIR infrared + temperature & humidity compensation
  • ★Protection Grade: IP54

9.5 Actuator & Meter

Electric Regulating Valve (KITOZER-V-E30)

  • ★Specification: DN50 3-way modulating type
  • ★Input Signal: 4-20mA
  • ★Valve Body Material: Stainless steel
  • ★Function: Equipped with position feedback
  • ★Protection Grade: IP65

Energy Meter (KITOZER-M-E30)

  • ★Accuracy Class: Class 0.2S
  • ★Measurable Parameters: Voltage/current/power/electric energy/harmonics
  • ★Communication Protocol: Modbus TCP
  • ★Function: Supports remote meter reading

9.6 Network Equipment

Industrial Switch (KITOZER-SW-16P)

  • ★Ports: 16-port Gigabit, 12-port POE power supply
  • ★Management Functions: Supports VLAN division & ring network redundancy
  • ★Protection Grade: IP50

Edge Computing Gateway (KITOZER-GW-EDGE4)

  • ★Protocol Conversion: Supports BACnet/IP, Modbus TCP, KNX, OPC UA
  • ★Computing Function: Edge AI computing
  • ★Network Access: 5G/fiber
  • ★Architecture: Redundant design

9.7 System Management Software

KITOZER-BMS-SOFT-H

  • ★Monitoring Points: ≥2,000 points
  • ★Visualization: Supports 2D/3D visualization
  • ★Control Algorithm: Built-in AI intelligent control algorithm
  • ★Integration Capability: Supports multi-system integration of fire protection/security/elevator
  • ★Operation & Maintenance Functions: Supports cloud remote operation & maintenance and predictive maintenance

10. Full Product Solutions

10.1 Small Building BMS Solution (Low-End Version)

10.1.1 Project Background

Small office buildings, apartments, shops (≤5,000 ㎡) requiring basic monitoring of HVAC, lighting and water supply & drainage equipment to reduce operation & maintenance costs and improve management efficiency.

10.1.2 Solution Design

Adopt KITOZER BMS low-end system: deploy temperature, humidity, light and human presence sensors on the Perception Layer to collect environmental parameters; apply KITOZER-DDC-108 controllers on the Automatic Control Layer for basic equipment control; equip KITOZER-BMS-H1 monitoring host + touch screen on the Management Application Layer for local monitoring & operation. The system adopts Modbus protocol communication with simple architecture and convenient deployment.

10.1.3 Core Functions

  1. Real-time monitoring of indoor temperature, humidity, light intensity and human presence status
  2. Automatic lighting control (lights off when unoccupied, lights on under low light)
  3. HVAC equipment start-stop control & manual temperature adjustment
  4. Water supply & drainage water pump operation status monitoring & fault alarm
  5. Historical data query & simple report generation

10.1.4 Solution Advantages

High cost performance with low deployment cost; simple installation & commissioning with short cycle; stable and reliable to meet basic management demands of small buildings.

10.2 Medium Building BMS Solution (Mid-End Version)

10.2.1 Project Background

Medium commercial buildings, hotels, hospitals (5,000-20,000 ㎡) requiring intelligent control of HVAC, lighting, water supply & drainage, elevators and power supply & distribution systems, refined energy consumption management, improved environmental comfort and reduced energy costs.

10.2.2 Solution Design

Adopt KITOZER BMS mid-end system: deploy high-precision temperature/humidity, COâ‚‚, air quality, pressure and flow sensors on the Perception Layer to fully collect environmental and equipment parameters; apply KITOZER-DDC-216 + KITOZER-PLC-300 controllers on the Automatic Control Layer for intelligent HVAC, chilled water and ventilation control & equipment linkage; equip KITOZER-BMS-S2 monitoring server + touch screen + remote tablet on the Management Application Layer for local & remote monitoring. The system adopts dual BACnet/Modbus protocols supporting multi-equipment access with intelligent control and energy consumption analysis functions.

10.2.3 Core Functions

  1. Real-time monitoring & automatic adjustment of indoor temperature, humidity, COâ‚‚ and air quality
  2. Intelligent HVAC control (PID regulation, sequence control, linkage control)
  3. Zoned intelligent lighting control (light + human induction linkage)
  4. Water supply & drainage flow/pressure monitoring & automatic water pump start-stop control
  5. Sub-item power consumption metering, energy consumption analysis & statistics of power supply & distribution systems
  6. Elevator operation status monitoring & fault alarm
  7. 1-year historical data storage, automatic report generation & energy-saving optimization reports
  8. Classified alarm management with SMS/APP alarm push

10.2.4 Solution Advantages

Intelligent control delivering remarkable energy-saving effects (15%-20% energy saving rate); refined energy consumption management cutting operating costs; stable and expandable system; convenient local + remote operation & maintenance.

10.3 Large Building / Building Cluster BMS Solution (High-End Version)

10.3.1 Project Background

Large commercial complexes, data centers, university campuses (≥20,000 ㎡) requiring comprehensive control of all building electromechanical equipment, AI intelligent optimization, predictive maintenance and multi-system integration to build green, efficient and intelligent buildings.

10.3.2 Solution Design

Adopt KITOZER BMS high-end system: deploy full-series high-precision sensors on the Perception Layer to fully collect building environmental and equipment parameters; apply KITOZER-DDC-432 + KITOZER-PLC-500 controllers on the Automatic Control Layer for high-precision control and complex linkage of HVAC, chilled water, ventilation, smoke exhaust, water supply & drainage and power supply & distribution systems; equip KITOZER-BMS-S4 dual redundant servers + high-definition touch screens + remote operation & maintenance terminals on the Management Application Layer for 2D/3D visual monitoring, AI intelligent optimization and predictive maintenance. The system supports multi-protocols including BACnet/IP, Modbus TCP, KNX and OPC UA, seamlessly connecting fire protection, security and elevator systems, supporting cloud remote operation & maintenance and centralized building cluster management.

10.3.3 Core Functions

  1. High-precision real-time monitoring & AI automatic adjustment of building environmental parameters (temperature, humidity, COâ‚‚, air quality)
  2. Full-process intelligent HVAC control (adaptive adjustment, load optimization, energy-saving operation)
  3. Precise control of chilled water flow, pressure and temperature with variable frequency energy-saving operation of water pumps
  4. Zoned, time-sharing and scene-based intelligent lighting control with refined energy consumption management
  5. Intelligent water supply & drainage monitoring, water leakage detection and automatic valve shutoff control
  6. Refined sub-item/zonal energy consumption metering, harmonic monitoring and energy optimization analysis of power supply & distribution systems
  7. Fire protection, security and elevator system linkage control with automatic emergency response
  8. Real-time equipment operation monitoring, health assessment and predictive maintenance for early fault warning
  9. 2D/3D visual monitoring intuitively displaying equipment layout and operating status of buildings
  10. Permanent historical data storage, intelligent report generation, energy-saving optimization reports and carbon emission statistics
  11. Cloud remote operation & maintenance, multi-terminal monitoring and 7×24-hour system guarantee
  12. Centralized building cluster management with cross-building data sharing and collaborative control

10.3.4 Solution Advantages

AI intelligent optimization achieving 25%-30% energy saving rate; predictive maintenance cutting operation & maintenance costs by over 30%; multi-system integration realizing comprehensive intelligent building management; dual redundant design delivering ultra-high system reliability; convenient cloud remote operation & maintenance with high management efficiency; adapting to complex demands of large buildings/clusters to support green low-carbon building operation.

10.4 Specialized Data Center BMS Solution

10.4.1 Project Background

Data centers require stable computer room temperature & humidity (22-26℃, 40%-60%RH), continuous power supply and safe equipment operation, realizing centralized monitoring and intelligent linkage of precision air conditioners, UPS, power distribution cabinets, fire-fighting equipment and water leakage detection systems.

10.4.2 Solution Design

Adopt KITOZER BMS high-end system customized for data center computer room environment and equipment characteristics: deploy high-precision temperature/humidity, differential pressure and water leakage detection sensors to monitor computer room environment in real time; apply KITOZER-DDC-432 controllers on the Automatic Control Layer for precise control and linkage of precision air conditioners, UPS, power distribution cabinets, fire-fighting equipment and water leakage detection systems; equip KITOZER-BMS-S4 servers on the Management Application Layer for 24-hour uninterrupted monitoring, alarm and data recording & analysis of computer room environment and equipment. The system supports remote operation & maintenance with real-time alarm push to guarantee safe and stable data center operation.

10.4.3 Core Functions

  1. Real-time monitoring of computer room temperature, humidity, differential pressure and air quality with automatic precision air conditioner adjustment
  2. Real-time water leakage detection, alarm and positioning
  3. UPS and power distribution cabinet operation status monitoring, real-time voltage/current/power display and fault alarm
  4. Fire protection system linkage control: automatically shut down air conditioners and cut off non-fire-fighting power supply upon fire alarm
  5. Real-time recording of equipment operation data, historical data query and report generation
  6. Remote monitoring & alarm push for all-time computer room status awareness

10.5 Hospital / Medical Building Specialized BMS Solution

10.5.1 Project Background

Hospital clean operating rooms, wards and inspection departments have strict requirements for temperature, humidity, cleanliness and pressure gradient to guarantee safe medical environments and stable equipment operation, realizing precise control of HVAC, clean air conditioning, lighting, water supply & drainage and medical equipment auxiliary systems.

10.5.2 Solution Design

Adopt KITOZER BMS mid/high-end system customized for hospital zone demands: deploy high-precision temperature/humidity, cleanliness, pressure and COâ‚‚ sensors to monitor environmental parameters in real time; apply KITOZER-DDC-432 controllers on the Automatic Control Layer for precise clean air conditioning & HVAC control, pressure gradient adjustment and air purification linkage; equip KITOZER-BMS-S2/S4 servers on the Management Application Layer for centralized monitoring, data recording and alarm management of environmental and equipment status in all zones. The system supports linkage of medical equipment auxiliary systems to guarantee safe medical environments and stable equipment operation.

10.5.3 Core Functions

  1. Precise monitoring & automatic adjustment of temperature, humidity, cleanliness and pressure gradient in clean operating rooms/wards
  2. Intelligent control of clean air conditioning & HVAC systems to guarantee comfortable and safe medical environments
  3. Zoned lighting control adapting to operation, diagnosis and nursing scenarios
  4. Water supply & drainage water quality and flow monitoring to guarantee safe medical water supply
  5. Linkage control of medical equipment auxiliary systems with fault alarm and emergency handling

11. Full Product Application Cases

11.1 Small Building Case: Apartment Building in Baiyun District, Guangzhou (4,500 ㎡)

11.1.1 Project Overview

A 12-story apartment building in Baiyun District, Guangzhou with total construction area of 4,500 ㎡, requiring basic monitoring of public area lighting, corridor air conditioning and water supply & drainage equipment to reduce operation & maintenance costs.

11.1.2 Applied Products

KITOZER BMS low-end system including KITOZER-BMS-H1 BMS monitoring host, KITOZER-DDC-108 DDC controllers, temperature sensors, light sensors, human presence sensors, industrial switches, touch screens, etc.

11.1.3 Application Effect

After system deployment, automatic public lighting control (lights off when unoccupied), remote corridor air conditioner temperature adjustment and real-time water pump operation monitoring were realized. Operation & maintenance personnel eliminated on-site patrols and managed equipment via touch screens, boosting operation & maintenance efficiency by 60% and cutting lighting energy consumption by 35%, winning high recognition from the property owner.

11.2 Medium Building Case: Business Hotel in Nanshan District, Shenzhen (18,000 ㎡)

11.2.1 Project Overview

A 25-story business hotel in Nanshan District, Shenzhen with total construction area of 18,000 ㎡ covering guest rooms, restaurants, meeting rooms and lobbies, requiring intelligent control and energy consumption management of HVAC, lighting, water supply & drainage, elevators and power supply & distribution systems.

11.2.2 Applied Products

KITOZER BMS mid-end system including KITOZER-BMS-S2 BMS monitoring server, KITOZER-DDC-216 DDC controllers, KITOZER-PLC-300 PLC controllers, high-precision temperature/humidity sensors, COâ‚‚ sensors, air quality sensors, energy meters, electric regulating valves, air damper actuators, edge computing gateways, touch screens, remote tablets, etc.

11.2.3 Application Effect

After system launch, automatic temperature & humidity adjustment of guest rooms, lobbies and meeting rooms, real-time air quality monitoring and fresh air linkage were realized alongside zoned intelligent lighting control and refined energy consumption metering. Annual comprehensive energy consumption decreased by 22%, operation & maintenance costs reduced by 28%, indoor comfort and customer satisfaction improved significantly, delivering remarkable operational benefits for the hotel.

11.3 Large Building Case: Commercial Complex in Tianhe District, Guangzhou (80,000 ㎡)

11.3.1 Project Overview

A 35-story commercial complex in Tianhe District, Guangzhou with total construction area of 80,000 ㎡ including shopping malls, office buildings, hotels and parking lots, requiring comprehensive electromechanical equipment control, AI intelligent optimization, multi-system integration and centralized building cluster management.

11.3.2 Applied Products

KITOZER BMS high-end system including dual redundant KITOZER-BMS-S4 BMS monitoring servers, KITOZER-DDC-432 DDC controllers, KITOZER-PLC-500 PLC controllers, full-series high-precision sensors, electric regulating valves, air damper actuators, energy meters, core switches, edge computing gateways, high-definition touch screens, remote operation & maintenance terminals, etc.

11.3.3 Application Effect

After system launch, 2D/3D visual monitoring, AI intelligent optimization control and predictive maintenance of all building equipment were realized. HVAC energy saving rate reached 28%, lighting energy saving rate hit 32%, and annual comprehensive energy consumption reduced by 26%. Fault early warning accuracy reached 90%, cutting operation & maintenance costs by 35%. The system seamlessly connected fire protection, security and elevator systems to realize comprehensive intelligent building management, becoming a benchmark intelligent project for commercial complexes in Guangzhou.

12. Search Keywords, SEO & Tag System

12.1 Keyword System

1. Core Primary Keywords

BMS Building Equipment Management System, Building Equipment Management System, Building Automation System, Intelligent Building Control System, Intelligent Building Integration System

2. High-Conversion Long-Tail Keywords

KITOZER BMS Building Equipment Management System Solution, BMS System Manufacturer, Custom Building Automation System, DDC Controller Manufacturer, Building Energy Consumption Monitoring & Management System, Intelligent Building Control Solution, BMS System Installation & Commissioning, Centralized Building Equipment Monitoring System

3. Industry Traffic Keywords

Intelligent Building, Building Intelligence, Smart Building, Electromechanical Equipment Monitoring, Building Automation, Smart Building, Green Building, Building Energy Saving, IoT for Buildings, Industrial Building Control

4. Brand Exclusive Keywords

Lai’an Intelligence, KITOZER, Lai’an BMS System, KITOZER Building Automation, Guangzhou Lai’an Intelligence, Lai’an Building Equipment Management

5. Drop-Down / Related Search Keywords

What is BMS System, BMS System Composition, BMS System Schematic Diagram, Building Automation System Brands, BMS System Configuration List, Building Equipment Management System Price, BMS System Technical Parameters, BMS System Application Cases

12.2 SEO Optimization Tag System

1. Core Page Optimization Tags

  • Title Tag: KITOZ