Table of Contents
Toggle1. System Introduction
The KITOZER Industrial On-site Control Integrated System is an all-in-one customized integration platform oriented to Industry 4.0 and intelligent manufacturing. It focuses on industrial on-site data collection, logic control, real-time monitoring, remote operation & maintenance, and equipment linkage, covering full-scenario demands including discrete manufacturing, process industry, intelligent equipment, and energy management. Designed in accordance with the 5-layer architecture of the international standard IEC62264, the system integrates core technologies such as PLC, DCS, SCADA, and Industrial Internet of Things (IIoT). It deeply combines sensors, controllers, actuators, industrial networks, human-machine interfaces, and data platforms to form a full closed-loop chain of “data-control-management-decision” for industrial sites.
As a benchmark for customized industrial integration, the KITOZER system supports non-standard customization, hardware OEM processing, technical confidentiality, and fast spot delivery. It adapts to harsh industrial environments with a wide temperature range of -40℃ ~ +70℃, dust, humidity, and strong electromagnetic interference. Featuring high reliability, strong scalability, and easy maintenance, three tiers of solutions (entry-level for basic control, standard-level for integrated monitoring, high-end for intelligent operation & maintenance) can be deployed on demand. It helps enterprises cut costs, boost efficiency, improve quality, and mitigate risks to build digital and intelligent industrial on-site control systems.
2. System Composition
Adopting a layered distributed architecture, the KITOZER Industrial On-site Control Integrated System consists of 5 major layers and 12 core units. All modules are interconnected via industrial networks to realize functional collaboration and data sharing.
2.1 Field Equipment Layer (L0)
- Sensor Unit: Temperature, pressure, flow, liquid level, vibration, rotational speed, photoelectric, proximity switches, etc., responsible for collecting physical signals on site.
- Actuator Unit: Contactors, relays, solenoid valves, electric regulating valves, frequency converters, servo drives, motors, etc., receiving control commands to execute actions.
- Field Instrument Unit: Smart transmitters, display meters, signal isolators, safety barriers, etc., for signal conversion, isolation, and local display.
2.2 Field Control Layer (L1)
- Core Controller Unit: PLC (Programmable Logic Controller), DCS Controller, RTU (Remote Terminal Unit), executing logical operation, closed-loop control, and sequence control.
- I/O Module Unit: Digital Input/Output (DI/DO), Analog Input/Output (AI/AO), special function modules (high-speed counting, motion control, communication modules).
- Local Operation Unit: On-site button boxes, indicator lights, simple operation panels, supporting local manual control and status indication.
2.3 Process Monitoring Layer (L2)
- HMI (Human-Machine Interface) Unit: Touch screens, industrial tablets, operator stations, realizing visualized on-site data, parameter setting, manual intervention, and alarm display.
- SCADA Data Acquisition & Monitoring Unit: Monitoring servers, data acquisition gateways, configuration software, responsible for full-system data aggregation, real-time monitoring, historical storage, and alarm management.
- Engineer Station Unit: Programming workstations, configuration tools, debugging software, used for system programming, configuration design, fault diagnosis, and program downloading.
2.4 Production Management Layer (L3)
- Data Storage Unit: Industrial servers, databases (SQL/MySQL), historical data archiving modules, realizing mass data storage and traceability.
- Production Scheduling Unit: MES (Manufacturing Execution System) interfaces, production report modules, energy consumption statistics modules, docking with enterprise production management workflows.
- Remote Operation & Maintenance Unit: Remote access gateways, VPN modules, mobile APP/WEB monitoring, supporting off-site remote monitoring, fault troubleshooting, and program updates.
2.5 Enterprise Decision Layer (L4)
- System Integration Unit: ERP interfaces, big data analysis modules, dashboard display systems, connecting industrial on-site data with enterprise management systems to support decision analysis.
2.6 Industrial Network & Auxiliary Units
- Industrial Communication Network: Industrial switches, industrial routers, fiber transceivers, communication cables (Profinet, Modbus, EtherCAT, TCP/IP).
- Power Supply & Distribution Unit: Industrial UPS, switching power supplies, power distribution cabinets, lightning arresters, ensuring stable system power supply and lightning protection.
- Cabinet & Protection Unit: Industrial control cabinets, operation consoles, dustproof and waterproof cabinets, cooling fans, air conditioners, meeting environmental protection requirements of on-site scenarios.
3. System Classification
The KITOZER Industrial On-site Control Integrated System is classified by four dimensions: control scale, application scenario, control mode, and industry attribute, to precisely match customized demands of different enterprises.
3.1 Classification by Control Scale
- Small Control System (10–50 I/O Points): Centered on PLC, matched with HMI and basic I/O modules, suitable for small equipment, single production lines, and independent station control, featuring low cost and fast deployment.
- Medium Control System (50–500 I/O Points): PLC + SCADA architecture, expanded with remote I/O and industrial networks, suitable for workshop-level production lines, multi-equipment linkage, and full-process monitoring of small and medium-sized factories.
- Large Control System (Over 500 I/O Points): DCS + Redundant PLC + IIoT architecture, supporting distributed control, redundant fault tolerance, and big data analysis, suitable for large factories, process industries, and park-level centralized management & control.
3.2 Classification by Application Scenario
- Discrete Manufacturing Control System: Adapted to auto parts, 3C electronics, mechanical processing, packaging & printing, focusing on logic control, motion control, equipment linkage, and beat optimization.
- Process Industry Control System: Adapted to chemical, petroleum, water treatment, food & beverage, energy & power industries, focusing on continuous process control, closed-loop control of temperature/pressure/flow, safety interlock, and explosion-proof protection.
- Intelligent Equipment Control System: Adapted to robots, CNC machine tools, intelligent warehouses, AGVs, automated assembly lines, focusing on motion control, positioning accuracy, collaborative control, and data interaction.
- Energy Management Control System: Adapted to factory energy consumption, photovoltaic energy storage, power distribution monitoring, HVAC, focusing on data collection, energy consumption analysis, energy-saving control, and remote operation & maintenance.
- Public Facility Control System: Adapted to smart parks, building automation, municipal engineering, environmental monitoring, focusing on remote monitoring, centralized management, and multi-site linkage.
3.3 Classification by Control Mode
- PLC Centralized Control System: A core PLC controls all equipment uniformly, with centralized wiring and simple programming, suitable for scenarios with concentrated equipment and simple workflows.
- DCS Distributed Control System: Decentralized control functions and centralized management; each controller operates independently and serves as backup for others, suitable for scenarios with complex processes and high reliability requirements.
- SCADA Remote Monitoring System: Centered on data acquisition and remote monitoring, suitable for geographically scattered multi-site scenarios and unattended operation.
- Hybrid Control System: Integrated PLC + DCS + SCADA, balancing discrete and process control, suitable for comprehensive factories with multi-scenario and complex processes.
3.4 Industry Customized Classification
- Auto Industry On-site Control Integrated System
- 3C Electronics Industry Automation Control System
- Explosion-proof DCS Control System for Chemical Industry
- PLC+SCADA Integrated System for Water Treatment Industry
- Sanitary Control System for Food & Beverage Industry
- Redundant Control System for Energy & Power Industry
- Intelligent Warehouse & Logistics Control System
- Clean-grade Control System for Pharmaceutical Industry
4. System Schematic Diagrams
4.1 Overall System Architecture Schematic
┌─────────────────────────────────────────────────────────────┐
│ Enterprise Decision Layer (L4) │
│ ERP Interface ── Big Data Analysis Platform ── Visual Dashboard │
└───────────────────────────────┬─────────────────────────────┘
│
┌───────────────────────────────▼─────────────────────────────┐
│ Production Management Layer (L3) │
│ Industrial Server/Database ── MES Interface ── Remote O&M Platform (APP/WEB) │
└───────────────────────────────┬─────────────────────────────┘
│
┌───────────────────────────────▼─────────────────────────────┐
│ Process Monitoring Layer (L2) │
│ SCADA Monitoring Server ── Engineer Station ── HMI Touch Screen/Operator Station │
└───────────────────────────────┬─────────────────────────────┘
│
┌───────────────────────────────▼─────────────────────────────┐
│ Field Control Layer (L1) │
│ Core Controller (PLC/DCS/RTU) ── I/O Module ── Industrial Switch │
└───────────────────────────────┬─────────────────────────────┘
│
┌───────────────────────────────▼─────────────────────────────┐
│ Field Equipment Layer (L0) │
│ Sensors (Temp/Pressure/Flow/Liquid Level) ── Actuators (Valves/Pumps/Motors) ── Field Meters │
└─────────────────────────────────────────────────────────────┘
4.2 Core Control Link Schematic
Field Sensors → AI Module → PLC Controller → Program Logical Operation → DO/AO Module → Actuators → Field Equipment Field Equipment Status → DI Module → PLC → SCADA Server → HMI/Remote Terminals → Operators
4.3 Network Communication Schematic
- Bottom Communication: Sensors/Meters ↔ I/O Modules (Modbus-RTU / 4-20mA)
- Control Layer Communication: PLC/DCS ↔ Industrial Switches (Profinet / EtherCAT / Modbus-TCP)
- Monitoring Layer Communication: SCADA Server ↔ HMI/Engineer Station (TCP/IP / OPC UA)
- Remote Communication: SCADA Server ↔ Remote O&M Platform (VPN / 4G / 5G / Ethernet)
5. Full System Configuration List (3 Tiers: Low / Medium / High, Brand: KITOZER)
5.1 Entry-level Configuration List (Small System, 10–50 I/O Points)
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | PLC | KZ-PLC-100 | 14 I/O points (8DI/6DO); Modbus-RTU/TCP; 24VDC operating voltage; -20℃~60℃ wide temp; Relay output 5A/250VAC | 1 | Set | KITOZER | Basic model with built-in Ethernet |
| 2 | Digital Input Module | KZ-DI-08 | 8-channel DI; NPN/PNP compatible; 24VDC input; 1500VAC isolation; Response time ≤1ms | 1 | Piece | KITOZER | Input expansion |
| 3 | Digital Output Module | KZ-DO-08 | 8-channel DO; Relay output; 5A/250VAC contact capacity; 1500VAC isolation; Service life ≥100,000 times | 1 | Piece | KITOZER | Output expansion |
| 4 | Analog Input Module | KZ-AI-04 | 4-channel AI; Supports 4-20mA/0-10V; Accuracy ±0.1%FS; 1500VAC isolation; Sampling frequency 10Hz | 1 | Piece | KITOZER | Collect temperature & pressure signals |
| 5 | HMI Touch Screen | KZ-HMI-700 | 7-inch TFT; 800×480 resolution; Modbus-TCP; 24VDC power supply; IP65 front panel; -20℃~60℃ wide temp | 1 | Set | KITOZER | Basic display & operation |
| 6 | Industrial Switch | KZ-SW-05 | 5-port 100M; Unmanaged; POE optional; IP30; -40℃~75℃ wide temp; Metal housing | 1 | Set | KITOZER | Connect PLC and HMI |
| 7 | Switching Power Supply | KZ-PWR-2405 | 24VDC/5A output; AC85-264V input; Efficiency ≥85%; Overcurrent/overvoltage/short-circuit protection; IP20 | 1 | Set | KITOZER | System power supply |
| 8 | Industrial Control Cabinet | KZ-CAB-400 | 400×300×200mm; Cold-rolled steel; IP54; Lockable door; 1 cooling fan; Black coating | 1 | Set | KITOZER | Install controllers & modules |
| 9 | Temperature Sensor | KZ-SEN-T100 | PT100; Measuring range -50℃~200℃; Accuracy ±0.15℃; 3-wire; IP65 | 2 | Pcs | KITOZER | On-site temperature collection |
| 10 | Proximity Switch | KZ-SEN-P01 | NPN normally open; 10mm detection distance; 24VDC; IP67; Response frequency 1kHz | 3 | Pcs | KITOZER | Equipment position detection |
5.2 Mid-tier Configuration List (Medium System, 50–500 I/O Points)
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | PLC | KZ-PLC-300 | 40 I/O points (24DI/16DO); Supports Profinet/Modbus-TCP; 24VDC; -30℃~70℃; Transistor output 0.5A/24VDC; 16MB program storage | 1 | Set | KITOZER | Standard model with high-speed counting |
| 2 | PLC Expansion Kit | KZ-EXP-300 | Max 10 expandable modules; Supports I/O & communication expansion; Backplane bus rate 10Mbps | 1 | Set | KITOZER | Expand system capacity |
| 3 | Digital Input Module | KZ-DI-16 | 16-channel DI; NPN/PNP compatible; 24VDC; 2500VAC isolation; Response time ≤0.5ms | 2 | Piece | KITOZER | Input expansion |
| 4 | Digital Output Module | KZ-DO-16 | 16-channel DO; Transistor/relay optional; 0.5A/24VDC transistor output; 2500VAC isolation; Service life ≥500,000 times | 2 | Piece | KITOZER | Output expansion |
| 5 | Analog Input Module | KZ-AI-08 | 8-channel AI; Supports 4-20mA/0-10V/PT100; Accuracy ±0.05%FS; 2500VAC isolation; Sampling frequency 50Hz | 2 | Piece | KITOZER | Multi-parameter signal collection |
| 6 | Analog Output Module | KZ-AO-04 | 4-channel AO; Output 4-20mA/0-10V; Accuracy ±0.1%FS; 2500VAC isolation; Load capacity ≤500Ω | 1 | Piece | KITOZER | Control regulating valves & inverters |
| 7 | HMI Touch Screen | KZ-HMI-1000 | 10-inch TFT; 1024×600 resolution; Profinet/OPC UA; 24VDC; IP65 front panel; -30℃~70℃; 1GB built-in storage | 1 | Set | KITOZER | High-definition display & operation |
| 8 | SCADA Monitoring Software | KZ-SCADA-STD | Supports 200 data acquisition points; Real-time monitoring, historical storage, alarm management; Modbus/Profinet compatible; Chinese configuration UI; Windows compatible | 1 | Set | KITOZER | Core system monitoring software |
| 9 | Industrial Switch | KZ-SW-08 | 8-port 100M; Managed; VLAN/POE support; IP30; -40℃~75℃; Metal housing; Redundant power supply | 2 | Set | KITOZER | Core industrial network |
| 10 | Industrial Server | KZ-SRV-200 | Intel i5 CPU; 8GB RAM; 256GB SSD; Dual Ethernet ports; Windows Server; -20℃~60℃ | 1 | Set | KITOZER | Data storage & SCADA operation |
| 11 | Switching Power Supply | KZ-PWR-2410 | 24VDC/10A output; AC85-264V input; Efficiency ≥90%; Overcurrent/overvoltage/short-circuit protection; IP20; Redundant design | 2 | Set | KITOZER | System redundant power supply |
| 12 | Industrial Control Cabinet | KZ-CAB-600 | 600×500×250mm; Cold-rolled steel; IP55; Lockable door; 2 cooling fans; Dust screen; Black coating | 1 | Set | KITOZER | Install controllers & modules |
| 13 | Temperature Sensor | KZ-SEN-T200 | PT1000; Measuring range -80℃~300℃; Accuracy ±0.1℃; 3-wire; IP65; High-temperature cable | 4 | Pcs | KITOZER | On-site temperature collection |
| 14 | Pressure Sensor | KZ-SEN-P200 | Measuring range 0–10MPa; 4-20mA output; Accuracy ±0.25%FS; IP67; Stainless steel; -40℃~80℃ wide temp | 2 | Pcs | KITOZER | Pipeline pressure collection |
| 15 | Flow Sensor | KZ-SEN-F200 | Turbine type; Measuring range 0.5–10m³/h; 4-20mA output; Accuracy ±0.5%FS; IP65; Fits DN25 pipelines | 1 | Pcs | KITOZER | Medium flow collection |
5.3 High-end Configuration List (Large System, Over 500 I/O Points)
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | DCS Distributed Control System | KZ-DCS-500 | Redundant controller; Supports Profinet/EtherCAT/OPC UA; 24VDC redundant power; -40℃~75℃; 64MB program storage; Redundant network; Fault switching ≤100ms | 2 | Set | KITOZER | Redundant core controller |
| 2 | Remote I/O Module | KZ-RIO-500 | Distributed I/O; Max 100 expandable nodes; Profinet/EtherCAT; IP65; -40℃~75℃; Redundant communication | 10 | Set | KITOZER | Distributed on-site collection |
| 3 | Digital Input Module | KZ-DI-32 | 32-channel DI; NPN/PNP compatible; 24VDC; 3000VAC isolation; Response time ≤0.1ms; Redundant input | 8 | Piece | KITOZER | Input expansion |
| 4 | Digital Output Module | KZ-DO-32 | 32-channel DO; Relay output; 8A/250VAC contact capacity; 3000VAC isolation; Service life ≥1,000,000 times; Redundant output | 8 | Piece | KITOZER | Output expansion |
| 5 | Analog Input Module | KZ-AI-16 | 16-channel AI; Supports 4-20mA/0-10V/PT100/Thermocouple; Accuracy ±0.02%FS; 3000VAC isolation; Sampling frequency 100Hz; Redundant input | 6 | Piece | KITOZER | Multi-parameter signal collection |
| 6 | Analog Output Module | KZ-AO-08 | 8-channel AO; Output 4-20mA/0-10V; Accuracy ±0.05%FS; 3000VAC isolation; Load capacity ≤1000Ω; Redundant output | 4 | Piece | KITOZER | Control regulating valves & inverters |
| 7 | Industrial HMI Touch Screen | KZ-HMI-1500 | 15-inch TFT; 1366×768 resolution; EtherCAT/OPC UA; 24VDC; IP65 front panel; -40℃~75℃; 8GB built-in storage; Explosion-proof optional | 2 | Set | KITOZER | High-definition display & operation |
| 8 | SCADA Monitoring Software | KZ-SCADA-PRO | Supports 10,000 data acquisition points; Real-time monitoring, historical archiving, alarm management, report analysis; EtherCAT/Profinet/OPC UA compatible; Redundant server; Chinese UI; Windows/Linux compatible | 1 | Set | KITOZER | Core system monitoring software |
| 9 | Core Industrial Switch | KZ-SW-24G | 24-port Gigabit; Managed; VLAN/POE/redundancy protocol support; IP30; -40℃~75℃; Metal housing; Dual redundant power supply | 4 | Set | KITOZER | Core industrial network |
| 10 | Redundant Industrial Server | KZ-SRV-500 | Intel i7 CPU; 32GB RAM; 1TB SSD; Quad Ethernet ports; Windows Server; -20℃~60℃; Redundant backup | 2 | Set | KITOZER | Data storage & SCADA operation |
| 11 | Engineer Workstation | KZ-ENG-500 | Intel i9 CPU; 64GB RAM; 2TB SSD; Dual monitors; Windows 10; Full programming/configuration/debug software suite | 1 | Set | KITOZER | System programming & debugging |
| 12 | UPS Uninterruptible Power Supply | KZ-UPS-3000 | 3KVA capacity; Online type; AC220V input; AC220V output; Backup duration ≥1 hour; Overvoltage/undervoltage/short-circuit protection; -20℃~60℃ | 2 | Set | KITOZER | Emergency system power supply |
| 13 | Explosion-proof Industrial Control Cabinet | KZ-CAB-800 | 800×600×300mm; Stainless steel; IP66; Explosion-proof grade Exd II BT4; Lockable door; Cooling air conditioner; Dust & waterproof; Gray coating | 2 | Set | KITOZER | For explosion-prone environments |
| 14 | Explosion-proof Temperature Sensor | KZ-SEN-T300 | PT100; Measuring range -100℃~500℃; Accuracy ±0.05℃; 3-wire; IP67; Exd II BT4 explosion-proof; High-temperature cable | 10 | Pcs | KITOZER | Temperature collection in explosion-prone areas |
| 15 | Explosion-proof Pressure Sensor | KZ-SEN-P300 | Measuring range 0–25MPa; 4-20mA output; Accuracy ±0.1%FS; IP68; Stainless steel; Exd II BT4; -40℃~120℃ wide temp | 6 | Pcs | KITOZER | Pressure collection in explosion-prone areas |
| 16 | Explosion-proof Flow Sensor | KZ-SEN-F300 | Vortex type; Measuring range 1–50m³/h; 4-20mA output; Accuracy ±0.2%FS; IP67; Exd II BT4; Fits DN50 pipelines | 4 | Pcs | KITOZER | Flow collection in explosion-prone areas |
| 17 | Remote O&M Gateway | KZ-GW-500 | 4G/5G/Ethernet compatible; VPN encryption; Protocol conversion (Modbus → OPC UA); Edge computing; IP30; -40℃~75℃ | 2 | Set | KITOZER | Remote monitoring & maintenance |
6. Full Product Technical Parameters
6.1 Core Controller (PLC/DCS) Technical Parameters
KZ-PLC-100 (Entry-level)
- Input Voltage: 24VDC ±10%
- I/O Points: 14 points (8DI/6DO)
- Processing Speed: 0.5μs per logic instruction
- Program Storage: 4MB
- Communication Interfaces: Ethernet (Modbus-TCP), RS485 (Modbus-RTU)
- Operating Temperature: -20℃ ~ 60℃
- Protection Grade: IP20
- Output Type: Relay (5A/250VAC)
KZ-PLC-300 (Mid-tier)
- Input Voltage: 24VDC ±10%
- I/O Points: 40 points (24DI/16DO), max 10 expandable modules
- Processing Speed: 0.2μs per logic instruction
- Program Storage: 16MB
- Communication Interfaces: Ethernet (Profinet/Modbus-TCP), RS485, High-speed Counter (100kHz)
- Operating Temperature: -30℃ ~ 70℃
- Protection Grade: IP20
- Output Type: Transistor (0.5A/24VDC) / Relay optional
KZ-DCS-500 (High-end)
- Input Voltage: 24VDC ±10% (Redundant)
- I/O Points: Redundant architecture, max expandable to 1000 points
- Processing Speed: 0.1μs per logic instruction
- Program Storage: 64MB
- Communication Interfaces: Ethernet (EtherCAT/Profinet/OPC UA), Redundant Network, High-speed Counter (1MHz)
- Operating Temperature: -40℃ ~ 75℃
- Protection Grade: IP30
- Redundant Switchover: ≤100ms, automatic fault switching
6.2 I/O Module Technical Parameters
Digital Input Module (KZ-DI-08/16/32)
- Input Channels: 8/16/32 channels
- Input Signal: 24VDC NPN/PNP
- Isolation Voltage: 1500VAC / 2500VAC / 3000VAC
- Response Time: ≤1ms / ≤0.5ms / ≤0.1ms
- Operating Temperature: -20℃~60℃ / -30℃~70℃ / -40℃~75℃
- Protection Grade: IP20
Digital Output Module (KZ-DO-08/16/32)
- Output Channels: 8/16/32 channels
- Output Type: Relay / Transistor
- Contact Capacity: 5A/250VAC (Relay), 0.5A/24VDC (Transistor)
- Isolation Voltage: 1500VAC / 2500VAC / 3000VAC
- Mechanical Service Life: ≥100,000 / ≥500,000 / ≥1,000,000 times
- Operating Temperature: -20℃~60℃ / -30℃~70℃ / -40℃~75℃
- Protection Grade: IP20
Analog Input Module (KZ-AI-04/08/16)
- Input Channels: 4/8/16 channels
- Input Signal: 4-20mA / 0-10V / PT100 / Thermocouple
- Accuracy: ±0.1%FS / ±0.05%FS / ±0.02%FS
- Isolation Voltage: 1500VAC / 2500VAC / 3000VAC
- Sampling Frequency: 10Hz / 50Hz / 100Hz
- Operating Temperature: -20℃~60℃ / -30℃~70℃ / -40℃~75℃
- Protection Grade: IP20
Analog Output Module (KZ-AO-04/08)
- Output Channels: 4/8 channels
- Output Signal: 4-20mA / 0-10V
- Accuracy: ±0.1%FS / ±0.05%FS
- Isolation Voltage: 1500VAC / 2500VAC
- Load Capacity: ≤500Ω / ≤1000Ω
- Operating Temperature: -20℃~60℃ / -30℃~70℃
- Protection Grade: IP20
6.3 HMI Technical Parameters
KZ-HMI-700 (Entry-level)
- Screen Size: 7-inch TFT
- Resolution: 800×480
- Communication Interface: Ethernet (Modbus-TCP)
- Power Supply: 24VDC ±10%
- Operating Temperature: -20℃ ~ 60℃
- Protection Grade: IP65 (Front Panel)
- Storage Capacity: 256MB
KZ-HMI-1000 (Mid-tier)
- Screen Size: 10-inch TFT
- Resolution: 1024×600
- Communication Interface: Ethernet (Profinet/OPC UA)
- Power Supply: 24VDC ±10%
- Operating Temperature: -30℃ ~ 70℃
- Protection Grade: IP65 (Front Panel)
- Storage Capacity: 1GB
KZ-HMI-1500 (High-end)
- Screen Size: 15-inch TFT
- Resolution: 1366×768
- Communication Interface: Ethernet (EtherCAT/OPC UA)
- Power Supply: 24VDC ±10%
- Operating Temperature: -40℃ ~ 75℃
- Protection Grade: IP65 (Front Panel), Explosion-proof optional
- Storage Capacity: 8GB
6.4 Industrial Network Equipment Technical Parameters
Industrial Switch (KZ-SW-05/08/24G)
- Port Quantity: 5-port 100M / 8-port 100M / 24-port Gigabit
- Management Type: Unmanaged / Managed / Managed
- Supported Protocols: VLAN / POE / Redundancy Protocol (High-end model)
- Power Supply: 24VDC ±10% (Redundant optional)
- Operating Temperature: -40℃ ~ 75℃
- Protection Grade: IP30
- Housing Material: Metal
Remote O&M Gateway (KZ-GW-500)
- Communication Modes: 4G / 5G / Ethernet
- Encryption Protocols: VPN / SSL
- Protocol Conversion: Modbus → OPC UA
- Edge Computing: Supports data preprocessing & protocol parsing
- Power Supply: 24VDC ±10%
- Operating Temperature: -40℃ ~ 75℃
- Protection Grade: IP30
6.5 Sensor Technical Parameters
Temperature Sensor (KZ-SEN-T100/T200/T300)
- Sensing Element: PT100 / PT1000 / PT100
- Measuring Range: -50℃~200℃ / -80℃~300℃ / -100℃~500℃
- Accuracy: ±0.15℃ / ±0.1℃ / ±0.05℃
- Wiring Mode: 3-wire
- Protection Grade: IP65 / IP65 / IP67
- Explosion-proof Grade: None / None / Exd II BT4 (High-end)
- Operating Temperature: -40℃ ~ 80℃
Pressure Sensor (KZ-SEN-P200/P300)
- Measuring Range: 0–10MPa / 0–25MPa
- Output Signal: 4-20mA
- Accuracy: ±0.25%FS / ±0.1%FS
- Protection Grade: IP67 / IP68
- Material: Stainless Steel
- Explosion-proof Grade: None / Exd II BT4 (High-end)
- Operating Temperature: -40℃~80℃ / -40℃~120℃
Flow Sensor (KZ-SEN-F200/F300)
- Measuring Principle: Turbine / Vortex
- Measuring Range: 0.5–10m³/h / 1–50m³/h
- Output Signal: 4-20mA
- Accuracy: ±0.5%FS / ±0.2%FS
- Protection Grade: IP65 / IP67
- Matching Pipe Diameter: DN25 / DN50
- Explosion-proof Grade: None / Exd II BT4 (High-end)
- Operating Temperature: -40℃ ~ 80℃
6.6 Power Supply & Cabinet Technical Parameters
Switching Power Supply (KZ-PWR-2405/2410)
- Output Voltage: 24VDC
- Output Current: 5A / 10A
- Input Voltage: AC85-264V
- Efficiency: ≥85% / ≥90%
- Protection Functions: Overcurrent / Overvoltage / Short-circuit protection
- Operating Temperature: -20℃ ~ 60℃
- Protection Grade: IP20
UPS Uninterruptible Power Supply (KZ-UPS-3000)
- Capacity: 3KVA
- Input Voltage: AC220V ±10%
- Output Voltage: AC220V ±5%
- Backup Duration: ≥1 hour
- Protection Functions: Overvoltage / Undervoltage / Short-circuit protection
- Operating Temperature: -20℃ ~ 60℃
Industrial Control Cabinet (KZ-CAB-400/600/800)
- Dimensions: 400×300×200mm / 600×500×250mm / 800×600×300mm
- Material: Cold-rolled steel / Stainless steel (High-end)
- Protection Grade: IP54 / IP55 / IP66 (High-end explosion-proof)
- Explosion-proof Grade: None / None / Exd II BT4 (High-end)
- Heat Dissipation: 1 fan / 2 fans / Cooling air conditioner (High-end)
- Operating Temperature: -20℃ ~ 60℃
7. Full Product Application Scope
7.1 Core Controller (PLC/DCS) Application Scope
- KZ-PLC-100: Small equipment control, single-station automation, standalone assembly line control, small fan/pump control, auxiliary equipment for factory automation.
- KZ-PLC-300: Small & medium production line control, multi-equipment linkage, workshop automation, packaging machinery, textile machinery, food processing equipment, HVAC control.
- KZ-DCS-500: Large process industries (chemical, petroleum, water treatment), energy & power (power plants, substations), large manufacturing (automotive assembly, iron & steel metallurgy), park-level centralized management, explosion-prone environment control.
7.2 I/O Module Application Scope
- Digital I/O Modules: Collection of equipment switch status, control of buttons/indicator lights, drive of relays/contactors, motor start-stop control, limit switch detection, solenoid valve control.
- Analog I/O Modules: Collection of continuous parameters including temperature, pressure, flow, liquid level; control of regulating valves/inverters; signal conversion for servo systems; sensor signal conditioning.
7.3 HMI Application Scope
- KZ-HMI-700: Local operation of small equipment, parameter setting, status display, simple fault alarm prompt, standalone equipment monitoring.
- KZ-HMI-1000: Workshop-level monitoring, production line parameter adjustment, real-time data display, historical trend query, alarm management, centralized multi-equipment operation.
- KZ-HMI-1500: Central control room of large factories, monitoring in explosion-prone areas, full-system data visualization, advanced alarm analysis, production report display, remote monitoring terminals.
7.4 Industrial Network Equipment Application Scope
- Industrial Switches: Construction of industrial local area networks, communication between PLC/DCS and HMI, multi-equipment networking, data transmission, redundant network construction.
- Remote O&M Gateway: Off-site remote monitoring, remote equipment fault troubleshooting, remote program updates, edge computing data preprocessing, 4G/5G wireless communication, VPN encrypted transmission.
7.5 Sensor Application Scope
- Temperature Sensors: Industrial furnace temperature, pipeline medium temperature, equipment surface temperature, ambient temperature, food processing temperature, clean area temperature collection for pharmaceutical industry.
- Pressure Sensors: Pipeline pressure, vessel pressure, hydraulic system pressure, pneumatic system pressure, water treatment pressure, chemical reactor pressure monitoring.
- Flow Sensors: Liquid/gas flow metering, pipeline flow monitoring, energy consumption statistics, water treatment flow control, chemical medium flow proportioning.
7.6 Power Supply & Cabinet Application Scope
- Switching Power Supply: Power supply for industrial equipment, PLC/HMI/I/O modules, sensors, control loops, wide-voltage input scenarios.
- UPS Power Supply: Power supply for central control room servers, emergency power supply for SCADA systems, power failure protection for key equipment, data loss prevention, power supply for precision instruments.
- Industrial Control Cabinets: Installation of control equipment, dustproof & waterproof protection, electromagnetic shielding, protection for equipment in explosion-prone environments, centralized management of on-site devices.
7.7 Overall Industry Application of the System
- Discrete Manufacturing: Auto parts, 3C electronics, mechanical processing, packaging & printing, furniture manufacturing.
- Process Industry: Chemical, petroleum & natural gas, water treatment, food & beverage, pharmaceutical, paper making.
- Energy & Power: Thermal power, hydropower, photovoltaic energy storage, substations, power distribution rooms.
- Intelligent Equipment: Industrial robots, CNC machine tools, intelligent warehouses, AGVs, automated assembly lines.
- Public Facilities: Smart parks, building automation, municipal engineering, environmental monitoring, sewage treatment plants.
- Other Industries: Metallurgy, mining, building materials, tobacco, logistics warehousing, HVAC.
8. Full Product Advantages
8.1 Core Brand Advantages
- Customized Industrial Integration: Over 10 years of experience in industrial on-site control, providing one-stop services including non-standard customization, hardware OEM, technical confidentiality, and fast spot delivery to meet personalized demands of various industries and scenarios.
- Full-series Product Line: Covers all categories of industrial control products including PLC, DCS, I/O modules, HMI, sensors, industrial networks, power supplies, and cabinets, enabling one-stop procurement with strong compatibility and unified after-sales service.
- Strict Quality Control: Products certified with ISO9001, CE, RoHS, and explosion-proof certification (high-end models). Designed for wide temperature range -40℃~+75℃ with IP65/IP66 high protection grade, stable operation under strong electromagnetic interference.
- High Cost Performance: Self-developed & self-produced with no intermediate links, more cost-effective than imported brands while matching performance of top international brands, suitable for budget-limited small & medium enterprises.
- Technical Confidentiality & OEM/ODM: Supports OEM/ODM processing, confidential technical scheme development, customized R&D, and fast response to customer demands.
8.2 Core Controller (PLC/DCS) Advantages
- KZ-PLC-100: Compact size, easy installation, simple programming, low cost for fast deployment of small projects; Modbus communication for strong compatibility; wide-temperature design for harsh environments.
- KZ-PLC-300: Modular design with strong expandability, fast processing speed and rich functions; Supports Profinet high-speed communication for small & medium production lines; Built-in high-speed counter for motion control; Stable operation from -30℃~70℃.
- KZ-DCS-500: Redundant architecture with high reliability and automatic fault switching, distributed control for large process industries; Supports EtherCAT real-time communication with high control precision; Explosion-proof design for hazardous environments; Powerful data processing capacity for big data analysis.
8.3 I/O Module Advantages
- Full-series Compatibility: Fully compatible with all KITOZER PLC/DCS models, plug-and-play without extra configuration.
- High Isolation Protection: 1500VAC~3000VAC high-voltage isolation to eliminate electromagnetic interference and protect controllers.
- High Precision & Stability: Analog modules with accuracy ±0.02%FS~±0.1%FS and low long-term drift; Digital modules with fast response and long service life.
- Wide-temperature Design: Operating range -40℃~75℃ to adapt to harsh industrial environments with high/low temperature and humidity.
8.4 HMI Advantages
- High-definition Display & Easy Operation: 7–15-inch high-definition touch screens with Chinese UI, easy to operate without professional training.
- Multi-protocol Compatibility: Supports mainstream industrial protocols including Modbus, Profinet, EtherCAT, OPC UA, compatible with controllers of all brands.
- High Protection Grade: IP65 front panel for dustproof & waterproof performance in harsh industrial sites.
- Wide Temperature & Explosion-proof Option: Operates from -40℃~75℃; high-end models support explosion-proof grade for hazardous environments.
8.5 Industrial Network Equipment Advantages
- Industrial-grade Stability: Metal housing, IP30 protection, -40℃~75℃ wide temperature resistance, anti-electromagnetic interference for long-term stable operation.
- High-speed Communication & Redundancy: Gigabit bandwidth with VLAN, POE and redundancy protocol support for stable data transmission and automatic fault switching.
- Convenient Remote O&M: Supports 4G/5G wireless communication, VPN encryption and edge computing to realize off-site remote monitoring & maintenance.
8.6 Sensor Advantages
- High Precision & Stability: Temperature accuracy ±0.05℃~±0.15℃, pressure accuracy ±0.1%FS~±0.25%FS with low long-term drift.
- High Protection & Explosion-proof: IP65~IP68 protection grade; high-end models with Exd II BT4 explosion-proof grade for humid, dusty and hazardous environments.
- Premium Material: Stainless steel construction with corrosion and wear resistance for extended service life.
8.7 Power Supply & Cabinet Advantages
- Wide Input Voltage & High Stability: AC85-264V wide input range with overcurrent/overvoltage/short-circuit protection for stable long-term power supply.
- High Protection & Explosion-proof: IP54~IP66 protection grade; high-end explosion-proof models for harsh environments.
- Optimized Heat Dissipation: Fan/air conditioner cooling design to prevent equipment damage from high temperature and extend service life.
8.8 System Solution Advantages
- Layered Design & Flexible Expansion: Three tiers (low/medium/high) for selection on demand, supporting later expansion to protect investment.
- Full Closed-loop Chain: Full closed-loop of data collection-control-monitoring-management-decision to boost production efficiency and cut operation & maintenance costs.
- Fast Deployment & Easy Maintenance: Modular design for simple installation; Chinese configuration UI for easy maintenance; remote O&M to reduce after-sales costs.
9. Product Tender Evaluation Parameters (Marked with *)
9.1 Core Controller (PLC/DCS) Tender Parameters
KZ-PLC-100
*14 I/O points (8DI/6DO) *Supports Modbus-RTU/TCP communication protocols *Operating voltage 24VDC ±10% *Wide operating temperature range -20℃~60℃ *Relay output contact capacity 5A/250VAC *Program storage capacity ≥4MB
KZ-PLC-300
*≥40 I/O points (24DI/16DO) *Max expandable modules ≥10 pieces *Supports Profinet/Modbus-TCP communication protocols *Operating voltage 24VDC ±10% *Wide operating temperature range -30℃~70℃ *Program storage capacity ≥16MB *Processing speed ≤0.2μs per logic instruction
KZ-DCS-500
*Redundant controller architecture, fault switching time ≤100ms *Supports EtherCAT/Profinet/OPC UA communication protocols *24VDC redundant operating power supply *Wide operating temperature range -40℃~75℃ *Program storage capacity ≥64MB *Max supported I/O points ≥1000 *Optional explosion-proof grade Exd II BT4
9.2 I/O Module Tender Parameters
Digital Input Module
*Input channels ≥8/16/32 *Supports NPN/PNP compatible input *Isolation voltage ≥1500VAC/2500VAC/3000VAC *Response time ≤1ms/≤0.5ms/≤0.1ms *Wide operating temperature range -20℃~60℃/-30℃~70℃/-40℃~75℃
Digital Output Module
*Output channels ≥8/16/32 *Relay output contact capacity ≥5A/250VAC *Isolation voltage ≥1500VAC/2500VAC/3000VAC *Mechanical service life ≥100,000/≥500,000/≥1,000,000 times *Wide operating temperature range -20℃~60℃/-30℃~70℃/-40℃~75℃
Analog Input Module
*Input channels ≥4/8/16 *Supports 4-20mA/0-10V/PT100 input *Accuracy ≤±0.1%FS/≤±0.05%FS/≤±0.02%FS *Isolation voltage ≥1500VAC/2500VAC/3000VAC *Sampling frequency ≥10Hz/≥50Hz/≥100Hz *Wide operating temperature range -20℃~60℃/-30℃~70℃/-40℃~75℃
Analog Output Module
*Output channels ≥4/8 *Output signal 4-20mA/0-10V *Accuracy ≤±0.1%FS/≤±0.05%FS *Isolation voltage ≥1500VAC/2500VAC *Load capacity ≤500Ω/≤1000Ω *Wide operating temperature range -20℃~60℃/-30℃~70℃
9.3 HMI Tender Parameters
KZ-HMI-700
*Screen size ≥7-inch TFT *Resolution ≥800×480 *Supports Modbus-TCP communication protocol *Power supply voltage 24VDC ±10% *Front panel protection grade IP65 *Wide operating temperature range -20℃~60℃
KZ-HMI-1000
*Screen size ≥10-inch TFT *Resolution ≥1024×600 *Supports Profinet/OPC UA communication protocols *Power supply voltage 24VDC ±10% *Front panel protection grade IP65 *Wide operating temperature range -30℃~70℃ *Storage capacity ≥1GB
KZ-HMI-1500
*Screen size ≥15-inch TFT *Resolution ≥1366×768 *Supports EtherCAT/OPC UA communication protocols *Power supply voltage 24VDC ±10% *Front panel protection grade IP65 *Wide operating temperature range -40℃~75℃ *Storage capacity ≥8GB *Optional explosion-proof grade Exd II BT4
9.4 Industrial Network Equipment Tender Parameters
Industrial Switch
*Port quantity ≥5-port 100M / 8-port 100M / 24-port Gigabit *Supports VLAN/POE/redundancy protocols (High-end model) *24VDC ±10% power supply (Redundant optional) *Wide operating temperature range -40℃~75℃ *Protection grade IP30 *Metal housing material
Remote O&M Gateway
*Supports 4G/5G/Ethernet communication modes *Supports VPN/SSL encryption protocols *Supports Modbus→OPC UA protocol conversion *24VDC ±10% power supply *Wide operating temperature range -40℃~75℃ *Protection grade IP30
9.5 Sensor Tender Parameters
Temperature Sensor
*Sensing element PT100/PT1000 *Measuring range -50℃~200℃/-80℃~300℃/-100℃~500℃ *Accuracy ≤±0.15℃/≤±0.1℃/≤±0.05℃ *Protection grade IP65/IP65/IP67 *Optional explosion-proof grade Exd II BT4 (High-end)
Pressure Sensor
*Measuring range 0–10MPa / 0–25MPa *4-20mA output signal *Accuracy ≤±0.25%FS / ≤±0.1%FS *Protection grade IP67 / IP68 *Stainless steel material *Optional explosion-proof grade Exd II BT4 (High-end)
Flow Sensor
*Measuring range 0.5–10m³/h / 1–50m³/h *4-20mA output signal *Accuracy ≤±0.5%FS / ≤±0.2%FS *Protection grade IP65 / IP67 *Matching pipe diameter DN25 / DN50 *Optional explosion-proof grade Exd II BT4 (High-end)
9.6 Power Supply & Cabinet Tender Parameters
Switching Power Supply
*Output voltage 24VDC *Output current ≥5A / ≥10A *Input voltage AC85-264V *Efficiency ≥85% / ≥90% *Overcurrent/overvoltage/short-circuit protection function *Wide operating temperature range -20℃~60℃
UPS Uninterruptible Power Supply
*Capacity ≥3KVA *Input voltage AC220V ±10% *Output voltage AC220V ±5% *Backup duration ≥1 hour *Overvoltage/undervoltage/short-circuit protection function *Wide operating temperature range -20℃~60℃
Industrial Control Cabinet
*Dimensions ≥400×300×200mm / 600×500×250mm / 800×600×300mm *Material: Cold-rolled steel / Stainless steel (High-end) *Protection grade IP54 / IP55 / IP66 (High-end) *Optional explosion-proof grade Exd II BT4 (High-end) *Heat dissipation configuration: Fan / Air conditioner (High-end)
10. Full Product Solutions
10.1 Small Equipment Automation Solution (Entry-level Configuration)
Solution Overview
Designed for small equipment, single stations and standalone assembly line control. Adopts KZ-PLC-100 + basic I/O modules + 7-inch HMI + sensors to realize equipment start-stop, parameter collection, local operation and simple alarm functions, featuring low cost, fast deployment and easy maintenance.
Core Functions
- Collection & control of equipment switch status
- Real-time monitoring of temperature/pressure/flow parameters
- Local parameter setting & status display
- Alarm prompts for over-temperature/over-pressure/faults
- Automatic logic control for standalone equipment
Application Scenarios
Small fan/pump control, standalone packaging machinery, food processing equipment, small assembly lines, standalone HVAC control.
10.2 Medium Production Line Integrated Solution (Mid-tier Configuration)
Solution Overview
For small & medium production lines, multi-equipment linkage and workshop automation. Adopts KZ-PLC-300 + expandable I/O modules + 10-inch HMI + SCADA software + industrial switches + sensors to realize centralized production line control, real-time monitoring, data storage, alarm management and optional remote operation, with modular expansion, stable performance and high cost performance.
Core Functions
- Linked logic control of multiple devices
- Real-time collection & monitoring of full production line parameters
- Historical data storage & trend query
- Hierarchical alarm management & fault traceability
- Workshop-level production report generation
- Optional remote monitoring & operation
Application Scenarios
Auto parts assembly lines, 3C electronics assembly lines, mechanical processing workshops, packaging & printing production lines, small & medium food & beverage production lines, textile machinery cluster control.
10.3 Large Process Industry Intelligent Solution (High-end Configuration)
Solution Overview
For large process industries, energy & power, explosion-prone environments and park-level centralized management. Adopts KZ-DCS-500 redundant controllers + remote I/O modules + 15-inch explosion-proof HMI + KZ-SCADA-PRO software + Gigabit industrial switches + redundant servers + explosion-proof sensors + UPS + explosion-proof cabinets to realize distributed redundant control, fault automatic switching, full-system intelligent monitoring, big data analysis and remote O&M, featuring high reliability, safety, intelligent maintenance and explosion-proof adaptability.
Core Functions
- Distributed redundant control with automatic fault switching
- High-precision collection & closed-loop control of full-process parameters
- Real-time monitoring, historical data archiving, advanced alarm analysis
- Production optimization & energy consumption analysis
- Safety interlock control for explosion-prone environments
- Remote O&M & edge computing
- Seamless docking with MES/ERP systems
Application Scenarios
Chemical reactor control, petroleum pipeline monitoring, large water treatment plants, thermal power plants, substations, complete automobile production lines, iron & steel metallurgy workshops, explosion-prone hazardous environments, park-level centralized management.
10.4 Intelligent Equipment Motion Control Solution
Solution Overview
For industrial robots, CNC machine tools, intelligent warehouses, AGVs and automated assembly lines. Adopts KZ-PLC-300 + motion control modules + servo drives + HMI + industrial switches to realize high-precision motion control, positioning control, synchronous control and equipment linkage, with fast response, high precision and stable performance.
Core Functions
- High-speed pulse output supporting servo/stepper control
- Multi-axis synchronous motion control
- Precise positioning control (accuracy ±0.1mm)
- Linked logic control of equipment
- Real-time monitoring & adjustment of motion parameters
Application Scenarios
Industrial robot control, CNC automation, intelligent warehouse stackers, AGV scheduling, synchronous control of automated assembly lines, precision processing equipment.
10.5 Energy Management & Energy-saving Solution
Solution Overview
For factory energy consumption, photovoltaic energy storage, power distribution monitoring and HVAC energy management. Adopts KZ-PLC-300 + AI modules + energy consumption sensors + SCADA software + remote gateways to realize energy data collection, energy consumption analysis, energy-saving control and remote monitoring, featuring precise metering, intelligent analysis and energy consumption reduction.
Core Functions
- Real-time collection of water, electricity, gas and heating energy consumption data
- Energy consumption statistics & analysis reports
- Abnormal energy consumption alarm for equipment
- Intelligent energy-saving control for HVAC
- Remote monitoring & upload of energy consumption data
Application Scenarios
Workshop energy management, photovoltaic energy storage system monitoring, intelligent power distribution room monitoring, HVAC energy saving for large buildings, park energy management.
10.6 Explosion-proof Industrial Control Solution
Solution Overview
For explosion-prone hazardous environments including chemical, petroleum, natural gas and pharmaceutical industries. Adopts KZ-DCS-500 explosion-proof controllers + explosion-proof I/O modules + explosion-proof HMI + explosion-proof sensors + explosion-proof cabinets to realize stable control, safety interlock and real-time monitoring in explosion-prone areas, featuring explosion-proof safety and high reliability for hazardous environments.
Core Functions
- Exd II BT4 explosion-proof grade suitable for hazardous areas
- Parameter collection & control in explosion-prone environments
- Safety interlock protection to prevent safety accidents
- Real-time monitoring of explosion-proof equipment status
- Fault alarm & emergency response
Application Scenarios
Chemical explosion-proof workshops, petroleum drilling platforms, natural gas pipelines, pharmaceutical clean explosion-proof areas, monitoring of flammable & explosive goods warehouses.
11. Product Application Cases
11.1 Auto Parts Production Line Control Case (Mid-tier Configuration)
Project Background
An auto parts manufacturer built 10 parts assembly lines to realize equipment linkage, parameter monitoring, production traceability and alarm management, improving production efficiency and product quality.
Solution Configuration
- Core Controller: 10 sets KZ-PLC-300
- I/O Modules: 20 pieces each of KZ-DI-16, KZ-DO-16, KZ-AI-08
- HMI: 10 sets KZ-HMI-1000
- SCADA Software: 1 set KZ-SCADA-STD
- Industrial Switches: 20 sets KZ-SW-08
- Sensors: Temperature, pressure and proximity switches (custom quantity)
Project Outcomes
- Production line automation rate increased to 95%, labor reduced by 60%
- Production efficiency up 30%, daily output increased by 2,000 pieces
- Product defect rate reduced below 0.5%, quality greatly improved
- Real-time monitoring & traceability, fault troubleshooting time cut by 70%
11.2 Chemical Reactor Explosion-proof Control Case (High-end Configuration)
Project Background
A chemical enterprise with 50 explosion-proof reactors required real-time monitoring of temperature, pressure, liquid level and flow, safety interlock, explosion-proof control and remote O&M to avoid safety accidents.
Solution Configuration
- Core Controller: 4 sets redundant KZ-DCS-500
- Remote I/O Modules: 20 sets KZ-RIO-500
- HMI: 4 explosion-proof sets KZ-HMI-1500
- SCADA Software: 1 set KZ-SCADA-PRO
- Industrial Switches: 4 sets KZ-SW-24G
- Industrial Servers: 2 redundant sets KZ-SRV-500
- Sensors: Explosion-proof temperature, pressure, liquid level and flow sensors (custom quantity)
- Explosion-proof Cabinets: 4 sets KZ-CAB-800
Project Outcomes
- Stable operation in explosion-prone environments with zero safety accidents
- Reactor parameter control accuracy ±0.1%FS, product qualification rate up to 99.8%
- Remote O&M eliminates on-site duty, operation & maintenance cost cut by 50%
- Fast response safety interlock, fault processing time ≤100ms
11.3 Small & Medium Food & Beverage Production Line Case (Mid-tier Configuration)
Project Background
A food & beverage company operated 3 bottled beverage production lines, requiring full-process automatic control of filling, capping, labeling and conveying, parameter monitoring and production reports to boost output.
Solution Configuration
- Core Controller: 3 sets KZ-PLC-300
- I/O Modules: 10 pieces each of KZ-DI-16, KZ-DO-16, KZ-AI-08
- HMI: 3 sets KZ-HMI-1000
- SCADA Software: 1 set KZ-SCADA-STD
- Industrial Switches: 6 sets KZ-SW-08
- Sensors: Flow, liquid level and proximity switches (custom quantity)
Project Outcomes
- 100% production line automation, labor reduced by 80%
- Production efficiency up 40%, daily output increased from 50,000 to 70,000 bottles
- Filling accuracy ±0.5% for stable product quality
- Real-time monitoring & reports for refined production management
11.4 Intelligent Warehouse AGV Scheduling Control Case (Mid-tier Configuration)
Project Background
An e-commerce intelligent warehouse with 20 AGVs required AGV scheduling, path planning, cargo handling and equipment linkage to improve warehouse efficiency.
Solution Configuration
- Core Controller: 2 sets KZ-PLC-300
- Motion Control Modules: 2 sets KZ-EXP-300
- HMI: 2 sets KZ-HMI-1000
- Industrial Switches: 4 sets KZ-SW-08
- AGV Drivers: 20 sets matching servo drives
Project Outcomes
- AGV scheduling response time ≤1s with optimal path planning
- Warehouse handling efficiency up 50%, labor reduced by 70%
- 100% cargo handling accuracy without misdelivery or omission
- 24-hour uninterrupted operation for higher warehouse throughput
11.5 Large Water Treatment Plant DCS Control Case (High-end Configuration)
Project Background
A municipal large-scale water treatment plant with 100,000 tons daily processing capacity required full-process monitoring of water inflow, sedimentation, filtration, disinfection and outflow, real-time water quality parameter monitoring, equipment control and remote O&M.
Solution Configuration
- Core Controller: 4 redundant sets KZ-DCS-500
- Remote I/O Modules: 30 sets KZ-RIO-500
- HMI: 4 sets KZ-HMI-1500
- SCADA Software: 1 set KZ-SCADA-PRO
- Industrial Switches: 4 sets KZ-SW-24G
- Industrial Servers: 2 redundant sets KZ-SRV-500
- Sensors: Water quality, flow, liquid level and pressure sensors (custom quantity)
Project Outcomes
- Full-process automatic control of water treatment without manual intervention
- Real-time monitoring of water quality parameters, 100% compliance rate of outflow water
- Equipment fault early warning, maintenance cost cut by 40%
- Remote O&M boosts management efficiency by 60%
12. Product Faults & Maintenance Guidelines
12.1 Core Controller (PLC/DCS) Common Faults & Maintenance
Common Faults
- Power Supply Fault: Failure to power on, indicator light off, frequent restart. Causes: Unstable supply voltage, damaged power module, loose wiring terminals.
- Communication Fault: Disconnection with HMI/I/O modules, interrupted data transmission. Causes: Damaged network cable, faulty communication module, incorrect protocol configuration, electromagnetic interference.
- I/O Fault: No input signal, no output action. Causes: Damaged I/O module, incorrect wiring, faulty sensors/actuators.
- Program Fault: Logic error, program loss, system crash. Causes: Wrong programming, damaged storage module, electromagnetic interference.
- Over-temperature Fault: Overheat alarm, high-temperature shutdown. Causes: Poor heat dissipation, excessive ambient temperature, damaged cooling fan.
Maintenance Schedule
- Daily Inspection: Check power indicators, communication status and operating temperature daily; wipe dust off controller surface and ensure ventilation.
- Monthly Maintenance: Check loose wiring terminals and damaged cables; test communication stability and I/O module sensitivity; back up programs and configuration parameters.
- Quarterly Maintenance: Clean cooling fans and replace dust screens; test power module output voltage; verify redundant switching function (High-end models).
- Annual Maintenance: Full hardware inspection of controllers; program version upgrade; calibrate I/O module accuracy; test grounding integrity.
12.2 I/O Module Common Faults & Maintenance
Common Faults
- Input Fault: No DI signal, abnormal AI readings. Causes: Damaged sensors, loose wiring, faulty module channels, electromagnetic interference.
- Output Fault: No DO action, abnormal AO output. Causes: Damaged actuators, incorrect wiring, broken module relays/transistors, overload.
- Communication Fault: Unresponsive modules, data transmission errors. Causes: Damaged backplane bus, poor module contact, incorrect protocol configuration.
- Over-temperature Fault: Excess module temperature, alarm shutdown. Causes: Poor heat dissipation, excessive ambient temperature, short-circuited load.
Maintenance Schedule
- Daily Inspection: Check module indicator lights daily; wipe surface dust.
- Monthly Maintenance: Check loose wiring terminals and damaged cables; test normal input/output signals; tighten module fixing screws.
- Quarterly Maintenance: Clean module heat dissipation channels; test module isolation voltage; replace aged cables.
- Annual Maintenance: Calibrate analog module accuracy; detect module insulation resistance; replace damaged modules.
12.3 HMI Common Faults & Maintenance
Common Faults
- Display Fault: Black screen, screen distortion, flickering. Causes: Power supply fault, broken screen, damaged backlight, faulty driver board.
- Touch Fault: Unresponsive touch, touch offset. Causes: Damaged touch panel, faulty touch driver, incorrect calibration, surface stains.
- Communication Fault: Failed connection with controller, static data display. Causes: Damaged network cable, faulty communication port, incorrect protocol configuration.
- System Fault: Crash, lag, lost configuration program. Causes: Corrupted system, damaged storage module, electromagnetic interference.
Maintenance Schedule
- Daily Inspection: Check display and touch functions daily; wipe screen stains with soft cloth (avoid liquid contact).
- Monthly Maintenance: Check loose wiring and damaged cables; calibrate touch accuracy; back up configuration programs.
- Quarterly Maintenance: Inspect cooling fan operation; wipe cabinet dust; test communication stability.
- Annual Maintenance: Upgrade system version; test screen backlight brightness; replace aged components.
12.4 Industrial Network Equipment Common Faults & Maintenance
Common Faults
- Port Fault: Unlit port indicator, connection failure. Causes: Damaged network cable, broken port, POE power supply fault.
- Communication Fault: Packet loss, network disconnection, high latency. Causes: Electromagnetic interference, overloaded switches, incorrect configuration, failed redundancy.
- Power Supply Fault: Failure to power on, indicator light off. Causes: Unstable power supply, damaged power module, loose wiring.
- Over-temperature Fault: Excess temperature, automatic restart. Causes: Poor heat dissipation, excessive ambient temperature, damaged cooling fan.
Maintenance Schedule
- Daily Inspection: Check port indicators and operating temperature daily; wipe equipment surface dust.
- Monthly Maintenance: Inspect wiring terminals and network cables; test network connectivity and packet loss rate; tighten fixing screws.
- Quarterly Maintenance: Clean cooling fans and dust screens; test power supply output voltage; verify redundant switching function.
- Annual Maintenance: Upgrade firmware version; test port performance; replace aged network cables and power modules.
12.5 Sensor Common Faults & Maintenance
Common Faults
- Temperature Sensor: Abnormal readings, heavy fluctuation, no signal. Causes: Damaged probe, loose wiring, poor contact, environmental interference.
- Pressure Sensor: Inaccurate readings, drift, no output. Causes: Damaged diaphragm, pipeline blockage, incorrect wiring, overload damage.
- Flow Sensor: Inaccurate metering, no signal, alarm trigger. Causes: Broken impeller/vortex piece, pipeline blockage, incorrect installation, damaged cables.
Maintenance Schedule
- Daily Inspection: Check stable sensor readings daily; wipe dirt and debris off probes.
- Monthly Maintenance: Check loose wiring and damaged cables; tighten sensor mounting screws; calibrate sensor accuracy.
- Quarterly Maintenance: Clean sensor probes; verify correct installation position; replace aged sealing parts.
- Annual Maintenance: Full sensor calibration; detect insulation resistance; replace damaged sensors.
13. Search Keywords & SEO Tag System
13.1 Core Keyword System
- Main Core Keywords Industrial on-site control integration, industrial control system, PLC control system, DCS distributed control, industrial automation integration
- High-conversion Long-tail Keywords Industrial on-site control integrated system solution, KITOZER industrial on-site control integration, customized PLC/DCS on-site control, industrial on-site control integration installation & commissioning, explosion-proof industrial on-site control system, industrial on-site control integration manufacturer
- Industry Traffic Keywords Intelligent manufacturing control system, industrial automation solution, IIoT control integration, factory on-site control renovation, industrial SCADA monitoring system, industrial network control integration
- Brand Exclusive Keywords LAIAN Intelligent industrial on-site control, KITOZER control integrated system, Guangzhou Laian Industrial Control, Laian Intelligent PLC control cabinet, KITOZER industrial control solution
- Drop-down & Related Search Keywords Best industrial on-site control integration supplier, industrial on-site control integration configuration list, industrial on-site control integration technical parameters, industrial on-site control integration application cases, industrial on-site control integration fault maintenance, industrial on-site control integration quotation
13.2 SEO Optimization Tag System
- Core Page Tags Page Theme: Industrial On-site Control Integrated System Solution Page Type: Product Solution Detail Page Core Tags: Industrial on-site control integration, PLC control, DCS control, industrial automation, KITOZER
- Title Tag Industrial On-site Control Integrated System Solution | PLC & DCS Custom Industrial Automation | Guangzhou Laian Intelligent
- Meta Keywords Industrial on-site control integration, industrial control system, PLC control system, DCS distributed control, industrial automation integration, KITOZER, Laian Intelligent
- Meta Description Guangzhou Laian Intelligent provides industrial on-site control integrated system solutions, full-series control equipment including PLC/DCS/SCADA, supporting customized integration, installation & commissioning, after-sales maintenance. Widely applied in intelligent manufacturing, chemical, water treatment, auto production lines and other scenarios, spot supply of KITOZER brand products.
- H1 Tag Industrial On-site Control Integrated System Solution
- H2 Tags (Segmented Use) Introduction to Industrial On-site Control Integrated System Composition & Classification of Industrial On-site Control Integrated System Industrial On-site Control Integration Configuration List (Entry / Medium / High-end) Technical Parameters of Industrial On-site Control Integration Products Industrial On-site Control Integration Application Cases & After-sales Service
- Internal Link Anchor Text Tags