Table of Contents
Toggle1. System Overview
The KITOZER energy storage container is an integrated and modular core energy storage device. It highly integrates battery units, energy management systems, temperature control systems, fire protection systems and power distribution systems inside a standard container shell. It features four core strengths: strong adaptability to outdoor environments, precise constant temperature & humidity control, plug-and-play rapid deployment, and flexible full-scenario expansion.
As a new-type energy storage carrier, this product line eliminates the bottlenecks of traditional energy storage power stations, including long construction cycles, high site requirements and complicated operation & maintenance. It can be widely applied to grid peak shaving, new energy consumption, industrial & commercial energy storage, off-grid microgrids, emergency backup power supplies and other scenarios, serving as core equipment for the energy transition era.
KITOZER energy storage containers strictly comply with ISO standards and energy storage industry specifications. They adopt anti-corrosion and rust-proof high-strength cabinets, intelligent BMS battery management, high-efficiency liquid cooling / air cooling temperature control, and clean heptafluoropropane fire suppression technology. The equipment adapts to extreme environments ranging from -40°C to 65°C, and supports customized standard sizes of 20ft and 40ft. Differentiated configuration packages can be provided according to low, medium and high power & capacity demands, balancing cost control and performance upgrade to guarantee stable operation throughout the full lifecycle.
2. System Composition
The KITOZER energy storage container consists of eight core subsystems. All subsystems operate collaboratively to form a closed-loop process covering energy storage, conversion, management and safety protection.
2.1 Energy Storage Battery Subsystem
The core energy carrier adopts lithium iron phosphate battery modules with high safety, long cycle life and low attenuation. Battery clusters are formed via series and parallel connections to deliver rated capacity and voltage, acting as the core unit for system energy storage.
2.2 Battery Management System (BMS)
The “intelligent nerve center” of the system. It real-time monitors single-cell voltage, temperature, SOC (State of Charge) and SOH (State of Health), implements overvoltage, undervoltage, overcurrent and overtemperature protection, balances battery consistency to ensure safe and stable battery operation, and supports data upload and remote monitoring.
2.3 Power Conversion System (PCS)
The core of energy conversion. It realizes bidirectional AC-DC conversion: converting alternating current to direct current for battery charging, and converting direct current to alternating current to feed power to the grid or supply loads during discharging. It supports power regulation, grid-connected control and off-grid switching functions.
2.4 Energy Management System (EMS)
The “brain” of the system. It coordinates and schedules the operation of all subsystems, receives grid dispatching instructions or user demands, optimizes charge-discharge strategies to realize peak-valley arbitrage, frequency & voltage regulation and load peak shaving. It also supports remote monitoring, data statistics and fault alarms.
2.5 Temperature Control Subsystem
The core environmental guarantee unit, available in air cooling and liquid cooling two solutions. It precisely controls internal container temperature (25°C±5°C) and humidity (40%-60%), integrating dehumidification, heating and heat dissipation functions to avoid degradation of battery performance and service life caused by extreme temperature and humidity.
2.6 Fire Protection Subsystem
The core safety protection unit equipped with heptafluoropropane gas fire extinguishing devices, paired with smoke, temperature and combustible gas detectors. It enables early fire warning and automatic fire suppression with no residue or pollution, perfectly matching fire suppression requirements of energy storage equipment. Emergency escape devices and fire emergency lighting are also equipped.
2.7 Power Distribution & Monitoring Subsystem
The core for power distribution and data acquisition, including high-voltage cabinets, low-voltage cabinets, combiner boxes, cable trays, lighting systems and earthing & lightning protection devices. It undertakes system power distribution, overcurrent/short-circuit protection and data collection & transmission, supporting local touch screen operation and remote platform monitoring.
2.8 Container Shell Subsystem
The physical protection carrier, made of standard 20ft/40ft high-strength steel structure. The outer wall undergoes anti-corrosion and rust-proof treatment while the inner wall is insulated, delivering rainproof, dustproof, shockproof and salt-spray resistant performance to adapt to complex outdoor environments. Inspection doors, cable interfaces and ventilation openings are reserved for equipment maintenance.
3. System Classification
KITOZER energy storage containers are categorized by four dimensions: application scenario, temperature control precision, power & capacity, and cabinet size. The two core series are outdoor energy storage containers and constant temperature & humidity containers to meet demands of various scenarios.
3.1 Classification by Application Scenario
- Grid-side Energy Storage Container: Designed for grid peak shaving, frequency regulation and voltage regulation. Featuring large capacity and high power, it supports grid-connected operation, responds to grid AGC commands and participates in grid frequency adjustment to stabilize power grid operation.
- User-side Energy Storage Container: Applied to industrial & commercial parks, factories and data centers. It realizes peak-valley electricity price arbitrage, load peak shaving and emergency backup power, reducing power consumption costs and improving power supply reliability.
- New Energy Supporting Energy Storage Container: Matched with wind and photovoltaic power stations to smooth fluctuating new energy output, resolve wind and solar curtailment issues, boost new energy consumption capacity and stabilize power output.
- Off-grid Microgrid Energy Storage Container: Suitable for remote mountainous areas, islands and off-grid regions. It forms an independent microgrid together with photovoltaic, wind power and diesel generators to deliver continuous and stable power supply.
- Emergency Energy Storage Container: Deployed for natural disasters, grid failures and emergency rescue. It supports rapid plug-and-play deployment to supply emergency backup power and guarantee power for critical equipment.
3.2 Classification by Temperature Control Precision
- Outdoor Energy Storage Container (Basic Temperature Control): Adopts air cooling for general outdoor environments, with temperature control range of -20°C to 50°C and humidity range of 40%-80%. It delivers high cost performance for conventional energy storage scenarios.
- Constant Temperature & Humidity Container (Precise Temperature Control): Equipped with integrated liquid cooling, dehumidification and heating systems for high humidity, high temperature, low temperature or precision equipment storage scenarios. Its temperature control range is -25°C to 30°C (precision ±0.5°C), humidity range 10%-90% (precision ±5%), applicable to precision energy storage, medical equipment and electronic component storage.
3.3 Classification by Power & Capacity
- Low Power & Small Capacity (50kW-500kW / 100kWh-1MWh): 20ft cabinet with air cooling temperature control, suitable for small industrial & commercial projects, distributed photovoltaic and off-grid microgrids.
- Medium Power & Medium Capacity (500kW-2MW / 1MWh-4MWh): 20ft/40ft cabinet with optional air cooling or liquid cooling, for medium industrial & commercial projects, new energy supporting and grid-side frequency regulation.
- High Power & Large Capacity (2MW-5MW / 4MWh-6MWh): 40ft cabinet with liquid cooling temperature control, for large power stations, grid peak shaving and new energy bases.
3.4 Classification by Cabinet Size
- 20ft Standard Container: Dimensions 6058mm×2438mm×2591mm, capacity 50kW-2MW, flexible for transportation and deployment of small and medium-sized energy storage projects.
- 40ft High Cube Container: Dimensions 12192mm×2438mm×2896mm, capacity 2MW-5MW, high capacity density for large-scale energy storage projects.
4. System Schematic Diagram
4.1 Schematic Diagram of Outdoor Energy Storage Container System
PV/Wind Power/Grid → High-Voltage Distribution Cabinet → PCS (Bidirectional Converter) → DC Combiner Box → Battery Cluster (Lithium Iron Phosphate Module) ↓ BMS (Battery Management System) ← Battery Cluster → EMS (Energy Management System) → Remote Monitoring Platform ↓ Temperature Control System (Air Cooling), Fire Protection System, Lighting System, Earthing & Lightning Protection System
4.2 Schematic Diagram of Constant Temperature & Humidity Container System
External Power Supply → Power Distribution System → PCS → DC Busbar → Battery Module / Precision Load ↓ BMS/Load Monitoring → EMS → Temperature Control System (Liquid Cooling + Constant Temp & Humidity) → Environmental Sensors (Temperature, Humidity, Smoke) ↓ Fire Protection System (Heptafluoropropane), Monitoring System, Emergency System
5. Full System Configuration List (Three Tiers: Low, Medium, High | Brand: KITOZER)
5.1 Low-Tier Configuration List (50kW/100kWh, 20ft Outdoor Energy Storage Container)
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Energy Storage Battery Module | KITOZER-LFP-50kWh | Rated Voltage: 51.2V; Rated Capacity: 1000Ah; Cycle Life ≥5000 times; Operating Temp: -20℃~60℃; IP67 Protection | 2 | Set | KITOZER | Lithium iron phosphate, 2 sets connected in series to reach 102.4V |
| 2 | Battery Management System (BMS) | KITOZER-BMS-50kW | Single cell voltage/temp monitoring; Over/under voltage, overcurrent & overtemperature protection; SOC accuracy ±3%; RS485/CAN communication | 1 | Set | KITOZER | Host + acquisition modules included |
| 3 | Power Conversion System (PCS) | KITOZER-PCS-50kW | Rated Power: 50kW; Conversion Efficiency ≥95%; Grid/off-grid switching; DC Voltage: 90-150V; AC Voltage: 380V±10% | 1 | Unit | KITOZER | Bidirectional AC/DC conversion |
| 4 | Energy Management System (EMS) | KITOZER-EMS-50kW | Charge-discharge strategy optimization; Peak-valley arbitrage; Remote monitoring; Data storage; Fault alarm; MODBUS protocol support | 1 | Set | KITOZER | Software + hardware included |
| 5 | Air Cooling Temperature Control System | KITOZER-TC-F-20ft | Temp Range: -20℃~50℃; Humidity 40%-80%; Cooling Capacity: 3kW; Heating Power: 2kW; IP54 | 1 | Set | KITOZER | Fans, condenser, heater & sensors included |
| 6 | Fire Protection System | KITOZER-FP-20ft | Heptafluoropropane fire suppression; Smoke & temperature detection; Auto alarm; 5kg fire extinguishing agent; IP54 | 1 | Set | KITOZER | Detectors, extinguishing device & alarm host included |
| 7 | High-Voltage Distribution Cabinet | KITOZER-HV-50kW | Rated Voltage: 1000V; Rated Current: 630A; Short-circuit, overcurrent & lightning protection; IP54 | 1 | Unit | KITOZER | Circuit breaker, fuse & lightning arrester included |
| 8 | DC Combiner Box | KITOZER-DC-50kW | Rated Voltage: 1000V; Rated Current: 630A; 4 input circuits, 1 output circuit; IP54 | 1 | Unit | KITOZER | Fuse, lightning arrester & monitoring module included |
| 9 | Container Shell | KITOZER-20ft-Outdoor | Size: 6058×2438×2591mm; Q235 high-strength steel; Anti-corrosion outer wall, insulated inner wall; IP56 | 1 | Unit | KITOZER | Standard 20ft outdoor cabinet |
| 10 | Lighting System | KITOZER-LT-20ft | 20W LED explosion-proof lamps (4 pcs); 1 emergency lamp; IP54 | 1 | Set | KITOZER | Lamps, switches & emergency power supply included |
| 11 | Earthing & Lightning Protection System | KITOZER-GND-20ft | Earthing resistance ≤4Ω; Class II lightning protection; Earth electrodes, lightning arresters & connecting wires included | 1 | Set | KITOZER | Ensures lightning protection safety of the whole system |
5.2 Medium-Tier Configuration List (1MW/2MWh, 20ft Constant Temperature & Humidity Container)
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Energy Storage Battery Module | KITOZER-LFP-100kWh | Rated Voltage: 51.2V; Rated Capacity: 2000Ah; Cycle Life ≥6000 times; Operating Temp: -30℃~65℃; IP67 | 20 | Set | KITOZER | Lithium iron phosphate, 20 sets series-parallel connected to reach 1024V |
| 2 | Battery Management System (BMS) | KITOZER-BMS-1MW | Single cell voltage/temp monitoring (±0.5% accuracy); Full protection; SOC ±2% accuracy; SOH monitoring; RS485/CAN/Ethernet | 1 | Set | KITOZER | Host + acquisition + equalization modules |
| 3 | Power Conversion System (PCS) | KITOZER-PCS-1MW | Rated Power: 1MW; Efficiency ≥97%; Seamless grid/off-grid switch; DC 800-1200V; AC 380V±5%; THDi ≤3% | 1 | Unit | KITOZER | Bidirectional AC/DC, liquid cooling heat dissipation |
| 4 | Energy Management System (EMS) | KITOZER-EMS-1MW | AI intelligent charge-discharge strategy; Peak-valley arbitrage, frequency & voltage regulation; 1-year data storage; IEC61850 protocol | 1 | Set | KITOZER | Software, hardware & server included |
| 5 | Liquid Cooling Constant Temp & Humidity System | KITOZER-TC-L-20ft | Temp -25℃~30℃ (±0.5℃); Humidity 10%-90% (±5%); Cooling 15kW; Heating 8kW; IP55 | 1 | Set | KITOZER | Liquid cooling unit, heat exchanger & sensors included |
| 6 | Fire Protection System | KITOZER-FP-20ft-PRO | Heptafluoropropane; Smoke, temp & combustible gas detection; Auto linkage alarm; 15kg agent; IP55 | 1 | Set | KITOZER | Detectors, extinguisher, alarm host & linkage modules |
| 7 | High-Voltage Distribution Cabinet | KITOZER-HV-1MW | Rated Voltage: 1500V; Rated Current: 1250A; Full protection & metering function; IP55 | 1 | Unit | KITOZER | Circuit breaker, fuse, arrester & electric meter included |
| 8 | DC Combiner Box | KITOZER-DC-1MW | Rated Voltage: 1500V; Rated Current: 1250A; 16 input, 2 output circuits; IP55 | 1 | Unit | KITOZER | Fuse, arrester, monitoring & communication modules |
| 9 | Container Shell | KITOZER-20ft-Constant | Size: 6058×2438×2591mm; Q345 high-strength steel; Double insulation, anti-static inner wall; IP56 | 1 | Unit | KITOZER | Standard 20ft constant temp & humidity cabinet |
| 10 | Lighting System | KITOZER-LT-20ft-PRO | 30W LED explosion-proof lamps (6 pcs); 2 emergency lamps; IP55 | 1 | Set | KITOZER | Lamps, switches, emergency power & indicator lights |
| 11 | Earthing & Lightning Protection System | KITOZER-GND-20ft-PRO | Earthing resistance ≤4Ω; Class I lightning protection; Real-time monitoring module; IP55 | 1 | Set | KITOZER | Lightning protection with real-time monitoring |
| 12 | Monitoring System | KITOZER-MON-1MW | 4-channel HD infrared cameras; Video storage; Remote access; IP55 | 1 | Set | KITOZER | Cameras, NVR & display screen included |
5.3 High-Tier Configuration List (5MW/6MWh, 40ft Constant Temperature & Humidity Container)
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Energy Storage Battery Module | KITOZER-LFP-150kWh | Rated Voltage: 51.2V; Rated Capacity: 3000Ah; Cycle Life ≥8000 times; Operating Temp: -40℃~65℃; IP68 | 40 | Set | KITOZER | Lithium iron phosphate, 40 sets series-parallel connected to reach 1024V |
| 2 | Battery Management System (BMS) | KITOZER-BMS-5MW | Ultra-precise monitoring; Full protection including arc fault protection; SOC ±1% accuracy; Active equalization; 5G communication; Redundant backup | 1 | Set | KITOZER | Host, acquisition & redundant active equalization modules |
| 3 | Power Conversion System (PCS) | KITOZER-PCS-5MW | Rated Power: 5MW; Efficiency ≥98%; Seamless switching; DC 800-1200V; AC 380V±3%; THDi ≤2%; Full redundant design | 1 | Unit | KITOZER | Bidirectional AC/DC, liquid cooling, redundant backup |
| 4 | Energy Management System (EMS) | KITOZER-EMS-5MW | AI strategy + virtual synchronous machine; Multi-protocol support; 3-year data storage; Redundant server & software | 1 | Set | KITOZER | Software, redundant hardware & server included |
| 5 | Liquid Cooling Constant Temp & Humidity System | KITOZER-TC-L-40ft | Temp -30℃~40℃ (±0.3℃); Humidity 10%-90% (±3%); Cooling 50kW; Heating 20kW; Redundant unit; IP56 | 1 | Set | KITOZER | Full set of liquid cooling equipment with redundant backup |
| 6 | Fire Protection System | KITOZER-FP-40ft-PRO | Multi-type detectors including arc sensor; Remote APP alarm; 50kg extinguishing agent; Redundant control modules; IP56 | 1 | Set | KITOZER | Complete linkage fire suppression system with redundancy |
| 7 | High-Voltage Distribution Cabinet | KITOZER-HV-5MW | Rated Voltage: 1500V; Rated Current: 2500A; Full protection, metering & redundant design; IP56 | 1 | Unit | KITOZER | Full set of electrical components with redundant backup |
| 8 | DC Combiner Box | KITOZER-DC-5MW | Rated Voltage: 1500V; Rated Current: 2500A; 32 input, 4 output circuits; IP56 | 1 | Unit | KITOZER | Full monitoring & communication modules with redundancy |
| 9 | Container Shell | KITOZER-40ft-Constant | Size: 12192×2438×2896mm; Q345 steel; Double insulation, fireproof anti-static inner wall; IP56 | 1 | Unit | KITOZER | Standard 40ft high cube constant temp & humidity cabinet |
| 10 | Lighting System | KITOZER-LT-40ft-PRO | 40W LED lamps (10 pcs); 4 emergency lamps; Intelligent control; IP56 | 1 | Set | KITOZER | Smart lighting & emergency indication system |
| 11 | Earthing & Lightning Protection System | KITOZER-GND-40ft-PRO | Class I lightning protection; Real-time monitoring & redundant modules; Earthing resistance ≤4Ω; IP56 | 1 | Set | KITOZER | Redundant lightning protection with data monitoring |
| 12 | Monitoring System | KITOZER-MON-5MW | 8-channel HD infrared cameras; 3-year video storage; AI intelligent analysis; Remote control; IP56 | 1 | Set | KITOZER | AI video monitoring system with storage equipment |
| 13 | Auxiliary System | KITOZER-AUX-5MW | 10kVA UPS, industrial air conditioner, dehumidifier & backup power supply; IP56 | 1 | Set | KITOZER | Ensures stable operation of auxiliary equipment |
6. Full Product Technical Parameters
6.1 Energy Storage Battery Module Technical Parameters
表格
| Parameter | Low-Tier (50kWh) | Medium-Tier (100kWh) | High-Tier (150kWh) |
|---|---|---|---|
| Battery Type | Lithium Iron Phosphate (LFP) | Lithium Iron Phosphate (LFP) | Lithium Iron Phosphate (LFP) |
| Rated Voltage | 51.2V | 51.2V | 51.2V |
| Rated Capacity | 1000Ah | 2000Ah | 3000Ah |
| Rated Energy | 50kWh | 100kWh | 150kWh |
| Cycle Life | ≥5000 cycles @80% DOD | ≥6000 cycles @80% DOD | ≥8000 cycles @80% DOD |
| Operating Temp Range | -20℃~60℃ | -30℃~65℃ | -40℃~65℃ |
| Storage Temp Range | -30℃~50℃ | -40℃~60℃ | -40℃~60℃ |
| Protection Grade | IP67 | IP67 | IP68 |
| Single Cell Voltage Accuracy | ±1% | ±0.5% | ±0.3% |
| SOC Accuracy | ±3% | ±2% | ±1% |
6.2 Battery Management System (BMS) Technical Parameters
表格
| Parameter | Low-Tier (50kW) | Medium-Tier (1MW) | High-Tier (5MW) |
|---|---|---|---|
| Monitoring Objects | Single cell voltage & temperature | Single cell voltage, temperature, SOC, SOH | Single cell voltage, temperature, SOC, SOH, SOP |
| Single Cell Voltage Monitoring Range | 0-5V | 0-5V | 0-5V |
| Single Cell Voltage Accuracy | ±1% | ±0.5% | ±0.3% |
| Temperature Monitoring Range | -40℃~125℃ | -40℃~125℃ | -40℃~125℃ |
| Temperature Monitoring Accuracy | ±1℃ | ±0.5℃ | ±0.3℃ |
| Protection Functions | Overvoltage, undervoltage, overcurrent, overtemperature | Overvoltage, undervoltage, overcurrent, overtemperature, short circuit, leakage | Overvoltage, undervoltage, overcurrent, overtemperature, short circuit, leakage, arc fault |
| Equalization Mode | Passive Equalization | Passive + Active Equalization | Active Equalization |
| Communication Interfaces | RS485/CAN | RS485/CAN/Ethernet | RS485/CAN/Ethernet/5G |
| Redundant Design | None | Host Redundancy | Host + Acquisition Module Redundancy |
6.3 Power Conversion System (PCS) Technical Parameters
表格
| Parameter | Low-Tier (50kW) | Medium-Tier (1MW) | High-Tier (5MW) |
|---|---|---|---|
| Rated Power | 50kW | 1MW | 5MW |
| Conversion Efficiency | ≥95% | ≥97% | ≥98% |
| DC Voltage Range | 90-150V | 800-1200V | 800-1200V |
| AC Voltage Range | 380V±10% | 380V±5% | 380V±3% |
| AC Frequency | 50Hz±0.5Hz | 50Hz±0.2Hz | 50Hz±0.1Hz |
| THDi | ≤5% | ≤3% | ≤2% |
| Grid/Off-Grid Switching | Manual Switching | Seamless Switching | Seamless Switching |
| Heat Dissipation Mode | Air Cooling | Liquid Cooling | Liquid Cooling |
| Protection Grade | IP54 | IP55 | IP56 |
| Redundant Design | None | None | Full Machine Redundancy |
6.4 Energy Management System (EMS) Technical Parameters
表格
| Parameter | Low-Tier (50kW) | Medium-Tier (1MW) | High-Tier (5MW) |
|---|---|---|---|
| Control Strategy | Basic Charge-Discharge | AI Intelligent Charge-Discharge | AI Strategy + Virtual Synchronous Machine |
| Core Functions | Peak-Valley Arbitrage, Remote Monitoring | Arbitrage, Frequency/Voltage Regulation, Remote Monitoring | Arbitrage, Regulation, Virtual Synchronous Machine, Remote Monitoring |
| Supported Communication Protocols | MODBUS | MODBUS/IEC61850 | MODBUS/IEC61850/DNP3 |
| Data Storage Duration | 3 Months | 1 Year | 3 Years |
| Remote Monitoring | Supported | Supported | 5G + Ethernet Dual Channel |
| Fault Alarm | Basic Alarm | Graded Alarm + Remote Push | Graded Alarm, Push + AI Fault Analysis |
| Redundant Design | None | Server Redundancy | Server + Software Redundancy |
6.5 Temperature Control System Technical Parameters
6.5.1 Air Cooling Temperature Control System (Low-Tier)
- Temperature Control Range: -20℃~50℃
- Humidity Control Range: 40%-80%
- Cooling Capacity: 3kW
- Heating Power: 2kW
- Fan Air Volume: 1000m³/h
- Protection Grade: IP54
6.5.2 Liquid Cooling Constant Temp & Humidity System (Medium & High-Tier)
表格
| Parameter | Medium-Tier (20ft) | High-Tier (40ft) |
|---|---|---|
| Temperature Control Range | -25℃~30℃ | -30℃~40℃ |
| Temperature Control Precision | ±0.5℃ | ±0.3℃ |
| Humidity Control Range | 10%-90% | 10%-90% |
| Humidity Control Precision | ±5% | ±3% |
| Cooling Capacity | 15kW | 50kW |
| Heating Power | 8kW | 20kW |
| Liquid Cooling Medium | Ethylene Glycol Aqueous Solution | Ethylene Glycol Aqueous Solution |
| Protection Grade | IP55 | IP56 |
6.6 Fire Protection System Technical Parameters
表格
| Parameter | Low-Tier (20ft) | Medium-Tier (20ft-PRO) | High-Tier (40ft-PRO) |
|---|---|---|---|
| Fire Extinguishing Medium | Heptafluoropropane | Heptafluoropropane | Heptafluoropropane |
| Extinguishing Agent Dosage | 5kg | 15kg | 50kg |
| Detection Types | Smoke + Temperature Sensor | Smoke + Temperature + Combustible Gas Sensor | Smoke + Temperature + Combustible Gas + Arc Sensor |
| Alarm Mode | Local On-Site Alarm | Local + Remote Alarm | Local + Remote + APP Push Notification |
| Response Time | ≤30s | ≤20s | ≤10s |
| Protection Grade | IP54 | IP55 | IP56 |
6.7 Container Shell Technical Parameters
表格
| Parameter | 20ft Outdoor (Low-Tier) | 20ft Constant Temp & Humidity (Medium-Tier) | 40ft Constant Temp & Humidity (High-Tier) |
|---|---|---|---|
| Dimensions (L×W×H) | 6058×2438×2591mm | 6058×2438×2591mm | 12192×2438×2896mm |
| Material | Q235 High-Strength Steel | Q345 High-Strength Steel | Q345 High-Strength Steel |
| Outer Wall Treatment | Anti-Corrosion & Rust-Proof Paint | Anti-Corrosion Paint + Insulation Layer | Anti-Corrosion Paint + Double Insulation Layer |
| Inner Wall Treatment | Ordinary Insulation | Anti-Static + Insulation | Anti-Static, Fireproof Coating + Insulation |
| Protection Grade | IP56 | IP56 | IP56 |
| Seismic Grade | Grade 8 | Grade 8 | Grade 8 |
| Anti-Corrosion Service Life | ≥10 Years | ≥15 Years | ≥20 Years |
7. Full Product Application Scope
7.1 Application Scope of Outdoor Energy Storage Containers
- Grid-Side Scenarios: Grid peak shaving, frequency regulation, voltage regulation and standby capacity to smooth grid load fluctuation and stabilize power grid operation.
- User-Side Scenarios: Industrial & commercial parks, factories, data centers and office buildings. Realize peak-valley arbitrage, load peak shaving and emergency backup power to cut electricity costs.
- New Energy Supporting Scenarios: Wind and photovoltaic power stations to smooth volatile renewable output, eliminate wind/solar curtailment and boost new energy consumption rate.
- Off-Grid Microgrid Scenarios: Remote mountainous areas, islands and grid-free zones. Form independent microgrids with PV, wind power and diesel generators for continuous stable power supply.
- Emergency Scenarios: Natural disasters, grid faults and emergency rescue. Rapid plug-and-play deployment to supply emergency power for critical equipment and medical facilities.
- EV Charging Pile Supporting Scenarios: Electric vehicle charging stations. Energy storage peak shaving reduces grid impact caused by charging loads and ensures stable charging performance.
7.2 Application Scope of Constant Temperature & Humidity Containers
- Precision Energy Storage Scenarios: Temperature & humidity sensitive energy storage equipment, high-end battery packs and precision power electronic devices to maintain stable operating environment.
- Medical Scenarios: Storage & transportation of vaccines, pharmaceuticals and biological reagents with strict temperature control (2-8℃) to preserve biological activity and safety.
- Electronics Industry Scenarios: Precision electronic components, semiconductor chips and circuit board storage & transportation, delivering moisture-proof, anti-corrosion and anti-static performance to guarantee product quality.
- Scientific Research Scenarios: Storage & transportation of lab equipment, precision instruments and research samples with accurate temperature & humidity control to ensure reliable experimental data.
- Archive & Cultural Relic Scenarios: Storage of important archives, cultural relics and artworks, with constant temperature & humidity to prevent mildew and corrosion and extend preservation lifespan.
- Industrial Scenarios: Storage & transportation of precision machinery, instruments and optical equipment, resisting vibration, moisture and corrosion to maintain equipment precision.
8. Full Product Advantages
8.1 Advantages of Outdoor Energy Storage Containers
- High Safety Performance: Adopts lithium iron phosphate batteries free from thermal runaway risks. Real-time multi-layer protection via BMS; clean heptafluoropropane fire suppression with zero pollution.
- Long Cycle Life: Battery cycle life ≥5000 times. Advanced BMS equalization improves battery consistency and extends system service life.
- Rapid Deployment: Prefabricated and fully integrated in factory. Only cable connection required on-site for plug-and-play use, cutting deployment cycle to 1-2 weeks, far shorter than traditional energy storage power stations.
- Strong Outdoor Adaptability: High-strength anti-corrosion cabinet with IP56 protection grade, adapting to extreme environments from -40℃ to 65℃, resistant to rain, dust, shock and salt spray.
- Flexible Expansion: Modular design supporting parallel connection of multiple units for flexible adjustment of power and capacity to match projects of different scales.
- Intelligent Operation & Maintenance: EMS remote monitoring for real-time operational data viewing, automatic fault alarms and remote diagnosis & maintenance to reduce O&M costs.
- Cost Advantage: Standardized mass production lowers equipment costs. Functions including peak-valley arbitrage and frequency regulation enable fast investment payback.
- Customization Service: Customizable cabinet size, power capacity, temperature control scheme and communication protocols to meet personalized project demands.
8.2 Advantages of Constant Temperature & Humidity Containers
- Precise Temperature & Humidity Control: Integrated liquid cooling constant temperature & humidity design with temperature precision ±0.3℃ and humidity precision ±3%, matching high-precision scenarios.
- High Protection Grade: IP56 protection with anti-static, fireproof, anti-corrosion and anti-mildew performance to secure precision equipment and materials.
- Wide Temperature Adaptation: Operating temperature range -30℃ to 40℃ covering low, normal and high temperature environments for cross-industry applications.
- Low Energy Consumption Operation: High-efficiency liquid cooling technology reduces energy consumption by 30% compared with traditional air cooling, saving operational costs.
- High Reliability: Redundant design of core components supports 24/7 uninterrupted operation for continuous stable performance in precision scenarios.
- High Integration of Multiple Functions: Integrated temperature control, fire protection, monitoring and power distribution systems with compact footprint and flexible deployment.
- Confidential Customization: Customizable cabinet appearance, internal layout and data interfaces with confidential project information protection.
- OEM/ODM Processing Service: Brand customization available with short delivery cycles for mass orders.
- Spot Inventory Supply: Regular models stocked in warehouse for fast delivery to meet urgent project demands.
8.3 Common Advantages of Full Product Line
- Self-Developed Full Industrial Chain: KITOZER independently develops and produces core components (batteries, BMS, PCS, EMS), ensuring controllable quality and high cost performance.
- Strict Quality Control: Each unit undergoes over 20 tests including high/low temperature, vibration and aging before delivery, complying with ISO, CE, UL and national standard certifications with product pass rate ≥99.9%.
- Full Lifecycle Service: One-stop service covering scheme design, manufacturing, installation, commissioning and maintenance with full-process technical support.
- Eco-Friendly & Low Carbon: Adopts environment-friendly materials, residue-free heptafluoropropane fire suppression and low-energy design, aligning with dual-carbon policy requirements.
9. Product Tender Control Parameters (* marks core tender control parameters)
9.1 Energy Storage Battery Module Tender Control Parameters
- Battery Type: Lithium iron phosphate battery with zero thermal runaway risk.
- Rated Energy: Low-tier ≥50kWh, Medium-tier ≥100kWh, High-tier ≥150kWh.
- Cycle Life: Low-tier ≥5000 cycles, Medium-tier ≥6000 cycles, High-tier ≥8000 cycles (@80% DOD).
- Operating Temperature Range: Low-tier -20℃~60℃, Medium-tier -30℃~65℃, High-tier -40℃~65℃.
- Protection Grade: Low-tier IP67, Medium-tier IP67, High-tier IP68.
9.2 BMS Tender Control Parameters
- SOC Accuracy: Low-tier ≤±3%, Medium-tier ≤±2%, High-tier ≤±1%.
- Single Cell Voltage Monitoring Accuracy: Low-tier ≤±1%, Medium-tier ≤±0.5%, High-tier ≤±0.3%.
- Protection Functions: Overvoltage, undervoltage, overcurrent, overtemperature, short circuit and leakage protection (arc fault protection included for high-tier).
- Communication Interfaces: RS485/CAN/Ethernet supported (5G added for high-tier).
- Equalization Mode: Medium and high tiers equipped with active equalization function.
9.3 PCS Tender Control Parameters
- Rated Power: Low-tier ≥50kW, Medium-tier ≥1MW, High-tier ≥5MW.
- Conversion Efficiency: Low-tier ≥95%, Medium-tier ≥97%, High-tier ≥98%.
- DC Voltage Range: 800-1200V (Medium & High Tiers).
- THDi: Low-tier ≤5%, Medium-tier ≤3%, High-tier ≤2%.
- Heat Dissipation Mode: Liquid cooling adopted for medium and high tiers.
9.4 EMS Tender Control Parameters
- Control Strategy: Medium and high tiers equipped with AI intelligent charge-discharge strategy.
- Communication Protocol: IEC61850 protocol supported (Medium & High Tiers).
- Data Storage Duration: Medium-tier ≥1 year, High-tier ≥3 years.
- Remote Monitoring: 5G + Ethernet dual-channel remote monitoring supported (High Tier).
9.5 Temperature Control System Tender Control Parameters
- Temperature Control Precision: Constant temp & humidity model ≤±0.5℃ (Medium Tier), ≤±0.3℃ (High Tier).
- Humidity Control Precision: Constant temp & humidity model ≤±5% (Medium Tier), ≤±3% (High Tier).
- Cooling Capacity: Medium-tier ≥15kW, High-tier ≥50kW.
9.6 Container Shell Tender Control Parameters
- Material: Q345 high-strength steel adopted for medium and high tiers.
- Protection Grade: IP56.
- Anti-Corrosion Service Life: Medium-tier ≥15 years, High-tier ≥20 years.
10. Full Product Solutions
10.1 Grid-Side Energy Storage Solution
For grid peak shaving, frequency regulation and voltage regulation demands, high-tier 40ft constant temperature & humidity energy storage containers (5MW/6MWh) are adopted. Multiple units are connected in parallel to form large-scale energy storage power stations. The EMS performs intelligent scheduling to charge during off-peak hours and discharge during peak hours for peak shaving, and rapidly responds to grid AGC commands for frequency regulation to stabilize grid operation. A matched remote monitoring platform tracks real-time equipment status, triggers automatic fault alarms and supports remote maintenance to reduce grid O&M costs.
10.2 Industrial & Commercial User-Side Energy Storage Solution
Designed for industrial & commercial peak-valley arbitrage and peak shaving, medium-tier 20ft constant temperature & humidity energy storage containers (1MW/2MWh) are deployed in single or parallel sets. The EMS optimizes charge-discharge strategies to charge during low-price valley periods and discharge during high-price peak periods to cut power costs, smooth load spikes and avoid transformer expansion investment. The system automatically switches to emergency power supply during grid outages to guarantee power for critical equipment. Remote monitoring and data statistics deliver accurate energy-saving benefit calculation.
10.3 New Energy Supporting Energy Storage Solution
Matching wind and photovoltaic power stations to mitigate volatile renewable output, medium or high-tier energy storage containers are deployed alongside power plants. The system smooths power fluctuation, eliminates wind/solar curtailment and improves grid-connected stability. The EMS links with new energy monitoring systems to coordinate power generation and energy storage strategies, maximizing renewable energy utilization efficiency.
10.4 Off-Grid Microgrid Energy Storage Solution
For power supply demands in remote mountainous areas and islands without grid access, low-tier 20ft outdoor energy storage containers (50kW/100kWh) form independent microgrids together with PV, wind power and diesel generators. PV/wind power supplies loads during daytime with surplus energy stored in containers; energy storage discharges power during night or low renewable output periods, while diesel generators serve as emergency backup. The EMS intelligently coordinates all power sources to optimize energy allocation, reduce diesel consumption and realize green low-carbon power supply.
10.5 Constant Temperature & Humidity Precision Storage Solution
For precision storage demands in medical, electronics, scientific research and cultural relic industries, medium or high-tier constant temperature & humidity containers are adopted. The system precisely controls internal temperature (±0.3℃) and humidity (±3%), delivering moisture-proof, anti-corrosion, anti-static and anti-mildew performance. Heptafluoropropane clean fire suppression ensures storage safety, while integrated monitoring tracks real-time temperature, humidity and fire sensor data with traceable remotely accessible records. Custom internal racks, partitions and lighting are supported to match diverse storage demands.
11. Product Application Cases
11.1 Grid-Side Case: Provincial Grid Peak Shaving Energy Storage Project
- Project Scale: 20 sets of KITOZER high-tier 40ft constant temperature & humidity energy storage containers, total capacity 100MW/120MWh
- Project Demand: Grid peak shaving, frequency regulation, voltage regulation, smooth load fluctuation and boost grid stability
- Project Outcome: Daily peak shaving energy volume 800,000 kWh, annual grid peak-valley difference reduced by 30%; grid frequency regulation response time ≤100ms with regulation accuracy ≥99%; annual grid operation cost saving of 20 million RMB
11.2 User-Side Case: Large Industrial Park Energy Storage Project
- Project Scale: 5 sets of KITOZER medium-tier 20ft constant temperature & humidity energy storage containers, total capacity 5MW/10MWh
- Project Demand: Peak-valley arbitrage, load peak shaving, emergency backup power
- Project Outcome: Annual arbitrage revenue of 8 million RMB; smooth load spikes cutting transformer expansion investment by 5 million RMB; emergency power supply during grid outages reducing annual power outage loss by 3 million RMB
11.3 New Energy Supporting Case: 100MW PV Power Station Energy Storage Project
- Project Scale: 10 sets of KITOZER medium-tier 20ft constant temperature & humidity energy storage containers, total capacity 10MW/20MWh
- Project Demand: Smooth PV output fluctuation, eliminate solar curtailment, improve grid-connected stability
- Project Outcome: PV output fluctuation reduced by 60%, solar curtailment rate down from 25% to 5%; annual additional PV power generation revenue of 12 million RMB; grid frequency regulation participation boosting power station grid rating with annual regulation subsidy of 3 million RMB
11.4 Off-Grid Microgrid Case: Island Microgrid Project
- Project Scale: 2 sets of KITOZER low-tier 20ft outdoor energy storage containers, total capacity 100kW/200kWh, matched with 500kW PV + 200kW diesel generator
- Project Demand: 24/7 power supply for island residents and industrial facilities with off-grid independent operation
- Project Outcome: 99.9% power supply reliability; self-consumption rate of PV power ≥80%, diesel fuel consumption reduced by 60%; annual diesel cost saving of 2 million RMB, improved living standards and industrial development on the island
11.5 Constant Temperature & Humidity Case: Biopharmaceutical Vaccine Storage Project
- Project Scale: 3 sets of KITOZER medium-tier 20ft constant temperature & humidity containers
- Project Demand: Constant temperature vaccine storage (2-8℃) to preserve vaccine activity and safety
- Project Outcome: Internal temperature stabilized at 5℃±0.5℃, humidity 50%±5%; vaccine shelf life extended by 20% with zero mildew or failure incidents; real-time traceable temperature & humidity data complying with GMP certification standards
12. Product Faults & Maintenance Specifications
12.1 Common Faults & Troubleshooting Methods
12.1.1 Energy Storage Battery Faults
- Abnormal Single Cell Voltage Fault Phenomenon: BMS triggers overvoltage/undervoltage alarm Solution: Stop charge-discharge operation, inspect loose battery connections and faulty BMS acquisition modules; replace single cells if necessary.
- Excessively High Battery Temperature Fault Phenomenon: BMS overtemperature alarm + temperature control system alert Solution: Shut down equipment immediately, inspect faulty air cooling/liquid cooling units, clear blocked heat dissipation channels, and restart after temperature returns to normal range.
- Sudden SOC Fluctuation Fault Phenomenon: Sharp jumps of SOC readings Solution: Calibrate BMS SOC parameters, optimize battery consistency via equalization maintenance, replace BMS acquisition modules if needed.
12.1.2 PCS Faults
- PCS Grid Connection Failure Fault Phenomenon: PCS fails to connect to grid and triggers grid fault alarm Solution: Inspect grid voltage/frequency, verify correct PCS grid parameter settings and unobstructed communication lines; restart PCS if necessary.
- Low PCS Conversion Efficiency Fault Phenomenon: Charge-discharge efficiency below 95% Solution: Inspect poor PCS heat dissipation and aging power modules, clean accumulated dust, replace power modules when aging occurs.
- PCS Protection Alarm Triggered Fault Phenomenon: Overcurrent/short-circuit/leakage protection alarm Solution: Shut down equipment immediately, inspect external short-circuit lines and abnormal loads, restart after fault elimination.
12.1.3 Temperature Control System Faults
- Abnormal Temperature Regulation Fault Phenomenon: Internal temperature exceeds set upper/lower limits Solution: Inspect faulty temperature sensors, non-operating fans/liquid cooling units and refrigerant leakage; clear heat dissipation channels, replace sensors or cooling units as required.
- Abnormal Humidity Regulation Fault Phenomenon: Excessively high or low internal humidity Solution: Inspect faulty dehumidification/heating modules and uncalibrated humidity sensors, clean dehumidifier filters, replace modules or sensors if needed.
12.1.4 Fire Protection System Faults
- False Smoke/Temperature Detector Alarm Fault Phenomenon: Fire alarm triggered without actual fire hazards Solution: Clean dust/moisture on detectors, calibrate sensitivity, replace detectors if damaged.
- Unresponsive Fire Extinguishing Device During Fire Hazards Fault Phenomenon: Extinguishing equipment fails to activate upon fire detection Solution: Inspect power supply of fire control devices, unobstructed control lines and normal cylinder pressure; replace control modules or gas cylinders if defective.
12.1.5 EMS Monitoring Faults
- Failed Data Upload Fault Phenomenon: EMS data stops updating, remote access unavailable Solution: Inspect network communication, loose communication lines and incorrect IP settings; restart EMS server.
- Unsent Fault Alerts Fault Phenomenon: No alert push upon equipment failure Solution: Verify correct alarm configuration and functional push modules, reconfigure alarm parameters with stable network connection.
12.2 Daily Maintenance Specifications
12.2.1 Daily Maintenance
- Log into EMS monitoring platform to check battery voltage, temperature, SOC, PCS operating parameters, internal temperature/humidity and fire protection status, confirm no abnormal alarms.
- Inspect container exterior for deformation, damage, water leakage and rust; verify intact door locks.
- Check temperature control fans and liquid cooling units for normal operation without abnormal noise.
- Confirm normal indicator light status of fire detectors and alarm equipment.
12.2.2 Weekly Maintenance
- Clean internal dust and debris of the container to keep heat dissipation channels unobstructed.
- Inspect battery module terminals for looseness, overheating and oxidation traces.
- Check wiring terminals of PCS, BMS and EMS for looseness and overheating.
- Calibrate temperature & humidity sensors to ensure data accuracy.
- Check fire cylinder pressure to maintain normal range.
12.2.3 Monthly Maintenance
- Conduct battery module equalization maintenance to improve battery consistency.
- Inspect refrigerant liquid level of temperature control systems, replenish refrigerant when insufficient; clean cooling filters.
- Test earthing & lightning protection systems to ensure earthing resistance ≤4Ω and intact lightning arresters.
- Perform functional tests of fire alarm and linkage systems to guarantee normal operation.
- Back up EMS operating data and export logs for archiving.
12.2.4 Annual Maintenance
- Conduct capacity testing for battery modules; replace modules with capacity attenuation exceeding 20%.
- Full inspection of PCS power modules, capacitors and inductors; replace aging components promptly.
- Derust and repaint container outer walls to extend anti-corrosion service life.
- Full calibration of all BMS and EMS parameters for precise monitoring and control.
- Complete system linkage test, simulate fault scenarios to verify protection and emergency response functions.
12.2.5 Long-Term Shutdown Maintenance
- Maintain battery SOC at 50%-60%; perform supplementary charging monthly to avoid over-discharge damage.
- Cut off external power supply, disconnect all switches and implement dust & moisture prevention measures.
- Inspect internal container temperature & humidity monthly to maintain dry ventilation.
- Start temperature control systems for 1 hour monthly to prevent component damage from moisture.
13. Factory Strength & After-Sales Service
13.1 Factory Strength
KITOZER owns a 100,000 ㎡ modern production base focusing on R&D, manufacturing, sales and service of energy storage containers and energy storage equipment with full independent industrial chain production capacity.
- R&D Strength: 200+ professional R&D team with 30% doctors and senior engineers, 15 years of deep cultivation in energy storage industry, holding over 320 intellectual property rights including more than 100 invention patents, participating in drafting multiple energy storage industry standards.
- Production Capacity: Imported German automated production lines, laser cutting machines, CNC bending machines and welding robots realize full-process automatic manufacturing with annual capacity of 5,000 energy storage containers. Regular models are stocked in warehouse, delivery cycle ≤30 days for bulk orders.
- Quality Control: Strict quality management system implemented. Every unit passes over 20 tests including high/low temperature, vibration, aging and salt spray before delivery, complying with ISO9001, ISO14001, CE, UL and national standards with product pass rate ≥99.9%.
- Supply Chain Advantage: Long-term strategic cooperation with top domestic battery and power electronic component suppliers to guarantee stable product quality and high cost performance.
13.2 After-Sales Service
Adhering to the philosophy of “Customer First, Service Oriented”, KITOZER delivers one-stop full lifecycle after-sales service to guarantee stable equipment operation for customers.
- Warranty Service
- Energy storage battery modules: 5-year warranty; free repair or replacement for non-man-made damage within cycle life.
- BMS, PCS, EMS: 3-year warranty; free repair or replacement for non-man-made damage.
- Container shell, temperature control, fire protection and power distribution systems: 2-year warranty; free repair or replacement for non-man-made damage.
- Lifetime maintenance: Cost-price repair service and lifelong technical support beyond warranty period.
- Technical Support Service
- 7×24-hour remote technical support: Professional engineering team online in real time, resolving faults and technical issues via phone, video and remote assistance within 1-hour response time.
- On-site technical service: Engineers arrive on-site within 24-48 hours for major faults or complex problems to provide on-site repair, commissioning and training services.
- Free technical training: Online and offline training on equipment operation, maintenance and fault troubleshooting to help customers cultivate professional O&M personnel.
- Spare Parts Supply Service
- National spare parts warehouses with core spare parts in stock for fast delivery to accelerate equipment repair.
- Free spare parts supply for non-man-made damage within warranty period; cost-price spare parts and bulk purchase discounts after warranty expiration.
- Regular Follow-Up Service
- Customer file establishment, monthly telephone follow-up and quarterly on-site visits to track equipment operation status, answer questions and deliver optimization suggestions.
- Regular push of equipment maintenance knowledge, latest industry technologies and policies to help customers improve O&M capabilities.
- Customization Service
- Customizable schemes, products, functions and appearance to meet personalized project demands.
- OEM/ODM processing service with customer brand customization and full confidentiality to protect customer rights and interests.
14. Conclusion
Against the backdrop of global energy transition and dual-carbon policies, energy storage, as the core support of new power systems, is embracing rapid development opportunities. KITOZER energy storage containers feature high safety, long service life, rapid deployment, strong environmental adaptability and intelligent operation & maintenance, covering full scenarios including grid-side, user-side, new energy supporting, off-grid microgrid and precision storage. We deliver efficient, reliable and economical energy storage solutions for global customers.
With years of deep cultivation in the energy storage industry, KITOZER takes technological innovation as the core, quality control as the foundation and customer service as the guarantee to continuously upgrade products and optimize solutions, supporting the green low-carbon transformation of the energy industry. Moving forward, KITOZER will uphold the core values of “Innovation, Quality, Service, Win-Win”, cooperate with global partners to drive high-quality development of the energy storage industry and contribute to sustainable global energy development.
15. SEO Optimization (Keywords & Tag System)
15.1 Search Keywords
15.1.1 Core Primary Keywords
Energy Storage Container, Energy Storage Container, Outdoor Energy Storage Container, Constant Temperature & Humidity Energy Storage Container, KITOZER Energy Storage Container
15.1.2 High Conversion Long-Tail Keywords
Grid Peak Shaving Energy Storage Container, Industrial & Commercial Energy Storage Container, New Energy Supporting Energy Storage Container, Off-Grid Microgrid Energy Storage Container, Precision Equipment Constant Temperature & Humidity Container, Lithium Iron Phosphate Energy Storage Container, 5MW Energy Storage Container, 1MW Energy Storage Container, Energy Storage Container Solution, Energy Storage Container Manufacturer
15.1.3 Industry Traffic Keywords
Energy Storage Equipment, Battery Energy Storage System, Container Energy Storage, Energy Management System, Power Conversion System, BMS Battery Management, Liquid Cooling Energy Storage Container, Air Cooling Energy Storage Container, Emergency Energy Storage Power Supply, Microgrid Energy Storage
15.1.4 Brand Exclusive Keywords
KITOZER Energy Storage Container, KITOZER Outdoor Energy Storage Container, KITOZER Constant Temperature & Humidity Container, KITOZER Energy Storage Equipment, KITOZER Energy Storage Solution
15.1.5 Drop-Down & Related Search Keywords
Energy Storage Container Price, Energy Storage Container Configuration, Energy Storage Container Technical Parameters, Energy Storage Container Application Scenarios, Energy Storage Container Maintenance, Energy Storage Container Manufacturer Ranking, 20ft Energy Storage Container, 40ft Energy Storage Container, Energy Storage Container Fire Protection System, Energy Storage Container Temperature Control System
15.2 SEO Optimization Tag System
15.2.1 Core Page Optimization Tag
Energy Storage Container Solution | KITOZER Outdoor / Constant Temperature & Humidity Energy Storage Container Manufacturer
15.2.2 Title Tag
KITOZER Energy Storage Container Solution | Outdoor Energy Storage Container | Constant Temperature & Humidity Energy Storage Container Manufacturer
15.2.3 Meta Keywords Tag
Energy Storage Container, Energy Storage Container, Outdoor Energy Storage Container, Constant Temperature & Humidity Energy Storage Container, KITOZER Energy Storage Container, Energy Storage Solution, Grid Peak Shaving Energy Storage, Industrial & Commercial Energy Storage, New Energy Supporting Energy Storage
15.2.4 Meta Description Tag
KITOZER specializes in R&D and production of energy storage containers, providing full-scenario solutions for outdoor energy storage containers and constant temperature & humidity energy storage containers. Our products feature high safety, long service life and rapid deployment, suitable for grid peak shaving, industrial & commercial energy storage and new energy supporting scenarios. Direct supply from manufacturer with worry-free after-sales service.
15.2.5 H1 Tag
KITOZER Energy Storage Container Solution
15.2.6 H2 Tags
System Overview, System Composition, System Classification, System Schematic Diagram, System Configuration List, Product Technical Parameters, Product Application Scope, Product Advantages, Tender Control Parameters, Product Solutions, Application Cases, Faults & Maintenance Specifications, Factory Strength & After-Sales Service, Conclusion
15.2.7 Internal Link Optimization Tags (Naturally Embedded Anchor Texts)
- Core Anchor Texts: Energy Storage Container, Outdoor Energy Storage Container, Constant Temperature & Humidity Energy Storage Container
- Long-Tail Anchor Texts: Grid Peak Shaving Energy Storage Container, Industrial & Commercial Energy Storage Container, New Energy Supporting Energy Storage Container, Energy Storage Container Solution
- Related Anchor Texts: Energy Storage Equipment, Battery Energy Storage System, Energy Management System, Power Conversion System
把文章中提到的KITOZER energy storage container的核心优势翻译成英文
用更简单的英文解释一下什么是能量存储容器。
推荐一些常见的能源存储容器的英文术语。