Toggle1. System Overview
A container data center is a prefabricated, modular and mobile integrated infrastructure built on standard ISO containers (10ft/20ft/40ft). It integrates complete functional subsystems including IT cabinets, power distribution, cooling, fire suppression, monitoring and cabling. Fully pre-assembled and tested in the factory, it can be rapidly deployed on-site for plug-and-play operation.
As a core solution for edge computing, disaster recovery centers, temporary computing capacity expansion and IT deployment at remote sites, it features a short deployment cycle (2–8 weeks), relocatable flexibility, high integration, low Total Cost of Ownership (TCO) and strong environmental adaptability. It can operate stably under extreme temperatures ranging from -40°C to +55°C, meeting high-density computing demands across telecommunications, energy, finance, military, intelligent manufacturing and other industries.
2. System Composition
The container data center consists of nine core subsystems: container enclosure structure, IT cabinet system, power supply & distribution system, cooling system, fire suppression system, environmental monitoring system, integrated cabling system, security system, and lighting & auxiliary system. Each module operates independently and works in coordination to form a fully enclosed operational environment.
2.1 Container Enclosure Structure
Constructed from high-strength Corten steel modified from standard ISO shipping containers, with five-sided thermal insulation layers composed of fireproof rock wool and metal cladding. It delivers windproof, rainproof, dustproof, anti-corrosion, anti-seismic and impact-resistant performance with an IP54+ protection rating, capable of resisting Category 12 typhoons and Magnitude 8 earthquakes.
2.2 IT Cabinet System
Comes standard with 19-inch standard racks (42U/47U) made of electrostatic-sprayed cold-rolled steel, supporting hot and cold aisle isolation. Each cabinet bears a maximum load of 1,000kg, with power density support ranging from 5kW to 20kW per cabinet, compatible with all types of IT hardware including servers, storage and network equipment.
2.3 Power Supply & Distribution System
Comprises UPS uninterruptible power supply, precision power distribution cabinets, PDU, storage batteries, ATS transfer switches and lightning protection grounding devices. It supports dual mains input with redundant UPS power supply to achieve 0ms load switching and continuous power supply, with backup time configurable from 10 to 60 minutes.
2.4 Cooling System
Three cooling modes are available: air cooling (in-row/ wall-mounted air conditioners), liquid cooling (CDU Cooling Distribution Unit) and hybrid cooling. Adopting enclosed hot/cold aisle design, precision temperature control and redundant backup, it maintains temperature accuracy of ±0.5°C and humidity between 40%–60%, meeting high-density heat dissipation requirements.
2.5 Fire Suppression System
Adopts HFC-227ea or FK-5-1-12 clean agent fire suppression, paired with smoke/heat detectors, audible-visual alarms and discharge indicators. The system automatically cuts power and shuts down air conditioning upon activation, with non-toxic and residue-free extinguishing agents to protect IT equipment.
2.6 Environmental Monitoring System
Powered by DCIM (Data Center Infrastructure Management) platform, it integrates sensors for temperature/humidity, water leakage, smoke, access control, UPS, air conditioning and power consumption. It supports real-time monitoring, remote alerts, intelligent linkage and 3D visualization, and connects to upper-layer management systems via SNMP/Modbus protocols.
2.7 Integrated Cabling System
Separates strong and weak current cabling, using flame-retardant cables, galvanized cable trays and cable managers. It supports 10G/40G fiber cabling with ample expansion space for high-speed data transmission, flexible capacity expansion and easy maintenance.
2.8 Security System
Integrates access control (card swiping/fingerprint/password), video surveillance, infrared intrusion detection and audible-visual alarms. It provides 24/7 real-time monitoring, abnormal alerts and permission management to safeguard physical security of the facility.
2.9 Lighting & Auxiliary System
Equipped with LED explosion-proof lighting, emergency lighting, exhaust fans, maintenance sockets and grounding devices to support daily operation, emergency response and safe grounding.
3. System Classification
3.1 Classification by Container Size
- 10ft Container Data Center: Dimensions 3048×2438×2896mm, IT load 20–30kW, 2–4 racks. Suitable for miniature edge computing, small-scale disaster recovery and remote sites.
- 20ft Container Data Center: Dimensions 6058×2438×2896mm, IT load 40–80kW, 4–8 racks. The mainstream standard model for medium-sized data centers, edge computing clusters and enterprise disaster recovery.
- 40ft Container Data Center: Dimensions 12192×2438×2896mm, IT load 80–200kW, 8–16 racks. High-density large-scale solution for large edge computing nodes, cloud computing hubs and high-density computing clusters.
3.2 Classification by Cooling Mode
- Air-cooled Type: Uses in-row/wall-mounted air conditioners, simple deployment and easy maintenance. Ideal for scenarios with power density ≤8kW per cabinet and mild ambient temperatures (-10°C ~ +45°C).
- Liquid-cooled Type: Equipped with CDU + cold plate liquid cooling, ultra-high heat dissipation efficiency with PUE ≤1.2. Designed for high-density scenarios with power density ≥10kW per cabinet and harsh temperatures (-40°C ~ +55°C).
- Hybrid Cooling Type: Combines direct liquid cooling on heat sources and auxiliary air cooling, balancing efficiency and cost. Fits power density of 8–15kW per cabinet and complex environmental conditions.
3.3 Classification by Power Density
- Low Density (≤5kW/rack): Air cooling solution, UPS capacity 30–60kVA, for standard servers and storage deployment.
- Medium Density (5–10kW/rack): In-row air cooling or entry-level liquid cooling, UPS capacity 60–120kVA, for virtualization clusters and medium-sized databases.
- High Density (≥10kW/rack): Liquid cooling solution, UPS capacity 120–200kVA, for AI computing, high-performance computing and big data analysis.
3.4 Classification by Deployment Scenario
- Standard Outdoor Type: IP54 protection, operating range -40°C ~ +55°C, directly deployed outdoors without civil building construction.
- Indoor Integrated Type: Installed inside factories/warehouses with simplified enclosure protection, optimized for cooling and monitoring performance.
- Explosion-proof & Anti-corrosion Type: IP65 protection rating, explosion-proof materials and anti-corrosion coatings, suitable for hazardous environments such as chemical plants, coal mines and oil & gas facilities.
4. System Principle Diagrams
4.1 Overall Architecture Logic
Mains Power Input → ATS Transfer Switch → UPS System → Precision PDU Cabinet → Cabinet PDU → IT Racks ↓ Storage Battery Pack ↓ Cooling System (Air Conditioner / CDU) ↓ Fire Suppression System (Clean Agent Fire Extinguishing) ↓ Environmental Monitoring System (DCIM) ↓ Security System (Access Control / Video Surveillance)
4.2 Power Supply & Distribution Logic
Dual Mains Input → ATS → UPS Input Distribution → UPS Main Unit → UPS Output Distribution → Precision Power Cabinet → Cabinet PDU → IT Load ↓ Storage Battery Pack (Backup Power Supply) ↓ Lightning Protection Grounding (Level 1/2/3)
4.3 Air Cooling Logic
Rack Hot Aisle → In-row Air Conditioner Return Air → Refrigeration Cycle → Cold Aisle Supply Air → Rack Air Intake → Equipment Heat Dissipation → Hot Aisle Circulation
4.4 Liquid Cooling Logic
IT Equipment Heat Source → Cold Plate Heat Absorption → CDU Cooling Unit → Closed Cooling Tower Heat Dissipation → Coolant Circulation Loop → Cold Plate
4.5 Fire Suppression Logic
Smoke/Heat Detectors → Alarm Host → Interlock Power Cut-off & Air Conditioner Shutdown → Clean Agent Discharge → Discharge Indicator & Audible-Visual Alarm
5. Full System Configuration List (KITOZER Brand: Low / Medium / High Tiers)
5.1 Low-tier Model (20ft, Low Density ≤5kW/rack, Air-cooled)
表格
| No. | Product Name | Model | Technical Specs | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Container Enclosure | KITOZER-20F-L | 20ft high cube, 6058×2438×2896mm, Corten steel, 5-sided insulation, IP54, Category 12 typhoon & Magnitude 8 earthquake resistance | 1 | Set | KITOZER | Anti-corrosion, thermal insulation & waterproof treatment included |
| 2 | IT Rack | KITOZER-R42-L | 42U, 600×1000×2000mm cold-rolled steel, 800kg load capacity, mesh door, hot/cold aisle compatible | 4 | Set | KITOZER | Includes tray, cable manager & adjustable feet |
| 3 | UPS Uninterruptible Power Supply | KITOZER-U60-L | 60kVA/54kW online double-conversion, 380V±15% input, output ±1% voltage, efficiency ≥94%, IP31 | 1 | Set | KITOZER | N+0 redundant, LCD display |
| 4 | Storage Battery Pack | KITOZER-B12-100-L | 12V 100Ah valve-regulated lead-acid, float voltage 13.5–13.8V, operating temp 0–40°C | 32 | Pcs | KITOZER | 15min backup runtime, with battery cabinet |
| 5 | Precision Power Distribution Cabinet | KITOZER-P80-L | 80A three-phase four-wire, 380V input, 12 output circuits, lightning protection, LCD power meter | 1 | Set | KITOZER | Input/output breakers & surge protector included |
| 6 | Rack PDU | KITOZER-PDU-10-L | 10 16A standard sockets, 220V input, surge & overload protection, aluminum housing | 4 | Pcs | KITOZER | 1 per rack |
| 7 | In-row Air Conditioner | KITOZER-C30-L | 30kW cooling capacity, precision temp control, airflow 8,000m³/h, 18–28°C, 40%–60% RH, IP54 | 2 | Set | KITOZER | N+1 redundant, outdoor unit included |
| 8 | Clean Agent Fire Suppression System | KITOZER-FM-70-L | 70L HFC-227ea, auto/manual activation, 8% extinguishing concentration, non-toxic | 1 | Set | KITOZER | Smoke/heat detectors, alarm host & discharge indicator included |
| 9 | DCIM Monitoring Host | KITOZER-M-L | Entry-level 1U 19-inch, Linux OS, 4 temp/humidity channels, 2 water leakage channels, RS485 support | 1 | Set | KITOZER | Monitoring software & local display included |
| 10 | Temp & Humidity Sensor | KITOZER-TS-01-L | Range -20°C~+60°C, accuracy ±0.5°C, 0–100%RH, NTC probe, 2m cable, IP65 | 4 | Pcs | KITOZER | 2 inside racks, 2 inside enclosure |
| 11 | Water Leakage Sensor | KITOZER-WS-01-L | 5m sensing cable, leak detection alarm output, IP65 | 2 | Pcs | KITOZER | Installed at enclosure bottom & AC area |
| 12 | Access Control Unit | KITOZER-AC-L | Card + password recognition, single door, electromagnetic lock & exit button | 1 | Set | KITOZER | Power supply & management software included |
| 13 | Network Camera | KITOZER-CAM-L | 2MP, infrared night vision, waterproof, 1080P, H.265 encoding | 2 | Pcs | KITOZER | Front & rear of container |
| 14 | Integrated Cabling System | KITOZER-CAB-L | Cat6 UTP, OM3 multimode fiber, galvanized trays, UL94-V0 flame retardant | 1 | Batch | KITOZER | All cables & auxiliary fittings included |
| 15 | Lighting System | KITOZER-LIT-L | 20W IP65 LED explosion-proof lamp, emergency lighting with 90min backup runtime | 4 | Set | KITOZER | Evenly distributed inside enclosure |
5.2 Medium-tier Model (20ft, Medium Density 5–10kW/rack, In-row Air-cooled)
表格
| No. | Product Name | Model | Technical Specs | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Container Enclosure | KITOZER-20F-M | 20ft high cube, 6058×2438×2896mm heavy-duty Corten steel, 50mm thick insulation, IP54, anti-corrosion coating upgrade | 1 | Set | KITOZER | Eaves, maintenance platform & anti-slip floor included |
| 2 | IT Rack | KITOZER-R42-M | 42U, 600×1200×2000mm cold-rolled steel, 1,000kg load, high-density mesh door, hot/cold aisle isolation, EMC shielding | 6 | Set | KITOZER | Blanking panels, cable racks & load-bearing casters included |
| 3 | UPS Uninterruptible Power Supply | KITOZER-U120-M | 120kVA/108kW modular online double-conversion, 380V±15% input, THDi ≤5%, output ±0.5% voltage, efficiency ≥96%, IP31 | 1 | Set | KITOZER | N+1 redundant, touch LCD screen |
| 4 | Storage Battery Pack | KITOZER-B12-150-M | 12V 150Ah VRLA, float voltage 13.5–13.8V, operating temp -10°C~45°C, long service life | 32 | Pcs | KITOZER | 30min backup runtime, intelligent battery management |
| 5 | Precision Power Distribution Cabinet | KITOZER-P120-M | 120A three-phase four-wire, 380V input, 16 output circuits, intelligent power monitoring, touch LCD | 1 | Set | KITOZER | Input breakers, molded case switches & Level 3 surge protection |
| 6 | Rack PDU | KITOZER-PDU-16-M | 16 32A sockets, 220V/380V input, surge protection, real-time current monitoring, remote switch control | 6 | Pcs | KITOZER | 1 per rack, remote power management |
| 7 | In-row Air Conditioner | KITOZER-C50-M | 50kW cooling capacity, EC variable-speed fan, airflow 12,000m³/h, 18–28°C, 40%–60% RH, IP54 | 3 | Set | KITOZER | N+1 redundant, high-efficiency outdoor unit & copper piping |
| 8 | Clean Agent Fire Suppression System | KITOZER-FM-90-M | 90L HFC-227ea, auto/manual/emergency triple activation, 8% extinguishing concentration | 1 | Set | KITOZER | Smoke/heat detectors, audible-visual alarm & emergency stop button |
| 9 | DCIM Monitoring Host | KITOZER-M-M | Standard 2U 19-inch, Linux OS, 8 temp/humidity, 4 water leakage, 2 smoke sensor channels, SNMP/Modbus support | 1 | Set | KITOZER | 10-inch touch screen & remote alert function |
| 10 | Temp & Humidity Sensor | KITOZER-TS-02-M | Range -30°C~+70°C, accuracy ±0.3°C, digital probe, 5m cable, IP65 | 6 | Pcs | KITOZER | 4 inside racks, 2 inside enclosure |
| 11 | Water Leakage Sensor | KITOZER-WS-02-M | 10m sensing cable, relay output alarm, IP65 | 3 | Pcs | KITOZER | Installed at enclosure bottom, AC & cable trench |
| 12 | Access Control Unit | KITOZER-AC-M | Fingerprint + card + password, dual-door controller, remote authorization | 1 | Set | KITOZER | Permission grading & management software included |
| 13 | Network Camera | KITOZER-CAM-M | 4MP, infrared night vision, waterproof, 2K, H.265 encoding, motion detection | 4 | Pcs | KITOZER | Full coverage on 4 sides of container |
| 14 | Integrated Cabling System | KITOZER-CAB-M | Cat7 UTP, OM4 multimode fiber, shielded cabling, UL94-V0 flame retardant | 1 | Batch | KITOZER | Shielded fittings & cable labeling included |
| 15 | Lighting System | KITOZER-LIT-M | 30W IP65 LED explosion-proof lamp, emergency lighting with 180min backup runtime, audible-visual interlock | 6 | Set | KITOZER | Distributed inside enclosure & aisles |
5.3 High-tier Model (40ft, High Density ≥10kW/rack, Liquid-cooled)
表格
| No. | Product Name | Model | Technical Specs | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Container Enclosure | KITOZER-40F-H | 40ft high cube, 12192×2438×2896mm special Corten steel, 80mm thick insulation, IP55, Magnitude 9 earthquake & salt spray anti-corrosion coating | 1 | Set | KITOZER | Eaves, maintenance platform, anti-slip floor & ventilation louvers |
| 2 | IT Rack | KITOZER-R47-H | 47U, 600×1200×2200mm heavy-duty cold-rolled steel, 1,500kg load, full hot/cold aisle isolation, Class A EMC shielding | 12 | Set | KITOZER | Blanking panels, cable racks, casters & ground busbar |
| 3 | UPS Uninterruptible Power Supply | KITOZER-U200-H | 200kVA/180kW modular online double-conversion, 380V±20% input, THDi ≤3%, output ±0.5% voltage, efficiency ≥97%, IP31 | 2 | Set | KITOZER | 2N redundant, parallel operation, touch LCD screen |
| 4 | Storage Battery Pack | KITOZER-B12-200-H | 12V 200Ah VRLA, float voltage 13.5–13.8V, operating temp -20°C~50°C, ultra-long service life | 64 | Pcs | KITOZER | 60min backup runtime, intelligent battery monitoring system |
| 5 | Precision Power Distribution Cabinet | KITOZER-P200-H | 200A three-phase four-wire, 380V input, 24 output circuits, harmonic suppression, touch LCD | 2 | Set | KITOZER | Input breakers, molded case switches & Level 4 surge protection |
| 6 | Rack PDU | KITOZER-PDU-32-H | 32 63A sockets, 220V/380V input, voltage/current monitoring, remote switch & energy statistics | 12 | Pcs | KITOZER | 1 per rack, overload & surge dual protection |
| 7 | Liquid Cooling CDU Unit | KITOZER-CDU-100-H | 100kW cooling capacity, dual redundant pumps, temperature difference control ±0.5°C, flow rate 10m³/h, 1.6MPa pressure, IP54 | 4 | Set | KITOZER | N+1 redundant, cold plates, pipelines & valves included |
| 8 | Closed Cooling Tower | KITOZER-CT-100-H | 100kW heat dissipation capacity, variable-frequency fans, temp range 20–30°C, IP55 | 2 | Set | KITOZER | N+1 redundant, matched with CDU liquid cooling system |
| 9 | Clean Agent Fire Suppression System | KITOZER-FM-120-H | 120L FK-5-1-12 clean agent, auto/manual/emergency triple activation, 6% extinguishing concentration | 2 | Set | KITOZER | Smoke/heat detectors, audible-visual alarm & emergency stop button |
| 10 | DCIM Monitoring Host | KITOZER-M-H | Premium 4U 19-inch, Linux OS, 16 temp/humidity, 8 water leakage, 4 smoke sensor channels, SNMP/Modbus/HTTP, 3D visualization | 2 | Set | KITOZER | 15-inch touch screen, mobile APP alert push |
| 11 | Temp & Humidity Sensor | KITOZER-TS-03-H | Range -40°C~+80°C, accuracy ±0.2°C, digital probe, 10m cable, IP67 | 12 | Pcs | KITOZER | 8 inside racks, 4 inside enclosure |
| 12 | Water Leakage Sensor | KITOZER-WS-03-H | 20m sensing cable, relay & audible-visual linkage alarm, IP67 | 6 | Pcs | KITOZER | Installed at enclosure bottom, AC, cable trench & CDU zone |
| 13 | Access Control Unit | KITOZER-AC-H | Face + fingerprint + card + password, 4-door controller, video linkage & audit log | 2 | Set | KITOZER | Permission grading & remote authorization software |
| 14 | Network Camera | KITOZER-CAM-H | 8MP, infrared night vision, waterproof, 4K, H.265 encoding, human shape detection | 8 | Pcs | KITOZER | 2 cameras on each side for full coverage |
| 15 | Integrated Cabling System | KITOZER-CAB-H | Cat8 shielded twisted pair, OM5 multimode fiber, full shielded cabling, UL94-V0 flame retardant | 1 | Batch | KITOZER | Shielded fittings, cable labels & management system |
| 16 | Lighting System | KITOZER-LIT-H | 50W IP65 LED explosion-proof lamp, emergency lighting with 240min backup runtime, intelligent dimming & audible-visual linkage | 12 | Set | KITOZER | Distributed inside enclosure, aisles & equipment zones |
6. Full Product Technical Specifications
6.1 Container Enclosure (KITOZER Series)
- Material: High-strength Corten steel / special Corten steel, five-sided thermal insulation (fireproof rock wool + metal cladding)
- Sizes: 10ft (3048×2438×2896mm), 20ft (6058×2438×2896mm), 40ft (12192×2438×2896mm)
- Protection Rating: IP54 (Low/Medium Tier), IP55 (High Tier)
- Disaster Resistance: Category 12 typhoon, Magnitude 8 earthquake (Low/Medium Tier), Magnitude 9 earthquake (High Tier)
- Operating Temperature: -40°C ~ +55°C for all models
- Floor Load Capacity: 500kg/㎡ (Low), 800kg/㎡ (Medium), 1,000kg/㎡ (High)
6.2 IT Rack (KITOZER-R Series)
- Sizes: 42U (Low/Medium), 47U (High); 600×1000×2000mm (Low), 600×1200×2000mm (Medium), 600×1200×2200mm (High)
- Material: Cold-rolled steel (Low/Medium), heavy-duty cold-rolled steel (High), electrostatic anti-corrosion coating
- Load Capacity: 800kg (Low), 1,000kg (Medium), 1,500kg (High)
- Door Panel: Mesh door with 75% ventilation rate (Low/Medium), high-density mesh door with 80% ventilation rate (High)
- Shielding: EMC shielding (Medium), Class A EMC shielding (High)
6.3 UPS Uninterruptible Power Supply (KITOZER-U Series)
- Topology: Online double-conversion, modular design
- Rated Capacity: 60kVA/54kW (Low), 120kVA/108kW (Medium), 200kVA/180kW (High)
- Input Parameters: 380V±15% (Low/Medium), 380V±20% (High), 50/60Hz±3%, power factor ≥0.99
- Output Parameters: 380V±1% (Low), ±0.5% (Medium/High), 50/60Hz±0.01%, sine wave, THDv ≤3% (Low), ≤1% (Medium/High)
- Efficiency: ≥94% online mode (Low), ≥96% (Medium), ≥97% (High); ≥99% ECO mode
- Protection Rating: IP31
- Operating Temperature: 0–45°C (Low), 0–50°C (Medium/High)
6.4 Storage Battery Pack (KITOZER-B Series)
- Type: Valve-regulated lead-acid maintenance-free battery
- Specifications: 12V100Ah (Low), 12V150Ah (Medium), 12V200Ah (High)
- Float Voltage: 13.5–13.8V
- Operating Temperature: 0–40°C (Low), -10°C~45°C (Medium), -20°C~50°C (High)
- Design Service Life: 5 years (Low), 8 years (Medium), 10 years (High)
6.5 Precision Power Distribution Cabinet (KITOZER-P Series)
- Rated Current: 80A (Low), 120A (Medium), 200A (High)
- Input Voltage: Three-phase four-wire 380V±15%
- Output Circuits: 12 circuits (Low), 16 circuits (Medium), 24 circuits (High)
- Protection: Overload, short circuit, leakage, lightning surge protection
- Display: LCD power meter (Low), touch LCD screen (Medium/High)
6.6 Rack PDU (KITOZER-PDU Series)
- Specifications: 10/16/32 standard sockets, 16A/32A/63A
- Input Voltage: 220V/380V
- Protection: Surge, overload, transient overvoltage protection; real-time current monitoring (Medium/High)
- Housing: Aluminum alloy, UL94-V0 flame retardant
- Control Function: Remote power switch (Medium), remote switch + alarm + energy statistics (High)
6.7 Cooling System (Air-cooled KITOZER-C / Liquid-cooled KITOZER-CDU Series)
6.7.1 In-row Air Conditioner (Air Cooling)
- Cooling Capacity: 30kW (Low), 50kW (Medium)
- Airflow: 8,000m³/h (Low), 12,000m³/h (Medium)
- Temperature & Humidity Range: 18–28°C, 40%–60% RH
- Protection Rating: IP54
- Fan Type: Fixed-speed (Low), EC variable-speed (Medium)
6.7.2 Liquid Cooling CDU Unit
- Cooling Capacity: 100kW
- Pump: Dual redundant automatic switching pumps
- Temperature Difference Control: ±0.5°C
- Flow Rate: 10m³/h
- Working Pressure: 1.6MPa
- Protection Rating: IP54
6.7.3 Closed Cooling Tower
- Heat Dissipation Capacity: 100kW
- Fan: Variable frequency, low noise & energy-saving
- Control Temperature Range: 20–30°C
- Protection Rating: IP55
6.8 Clean Agent Fire Suppression System (KITOZER-FM Series)
- Extinguishing Agent: HFC-227ea (Low/Medium), FK-5-1-12 (High)
- Tank Capacity: 70L (Low), 90L (Medium), 120L (High)
- Activation Mode: Auto/manual (Low), auto/manual/emergency stop (Medium/High)
- Extinguishing Concentration: 8% (HFC-227ea), 6% (FK-5-1-12)
- Toxicity: Non-toxic, residue-free, no equipment corrosion
6.9 DCIM Monitoring Host (KITOZER-M Series)
- Hardware: 1U 19-inch (Low), 2U (Medium), 4U (High), Linux operating system
- Monitoring Channels: 4 temp/humidity + 2 water leakage + 1 smoke sensor (Low); 8 temp/humidity + 4 water leakage + 2 smoke sensor + 1 access control (Medium); 16 temp/humidity + 8 water leakage + 4 smoke sensor + 2 access control (High)
- Communication Protocols: RS485 (Low), SNMP/Modbus (Medium), SNMP/Modbus/HTTP (High)
- Display: Local basic display (Low), 10-inch touch screen (Medium), 15-inch touch screen + 3D visualization (High)
- Alarm Function: Local on-site alarm (Low), remote alert push (Medium), remote alert + mobile APP notification (High)
6.10 Sensor Series (Temp/Humidity & Water Leakage)
6.10.1 Temperature & Humidity Sensor
- Measuring Range: -20°C~+60°C (Low), -30°C~+70°C (Medium), -40°C~+80°C (High)
- Accuracy: ±0.5°C (Low), ±0.3°C (Medium), ±0.2°C (High)
- Humidity Range: 0–100%RH
- Probe Type: NTC thermistor (Low), digital signal (Medium/High)
- Protection Rating: IP65 (Low/Medium), IP67 (High)
6.10.2 Water Leakage Sensor
- Sensing Cable Length: 5m (Low), 10m (Medium), 20m (High)
- Detection Precision: High-sensitivity leak detection
- Output Signal: Alarm signal only (Low), alarm + relay output (Medium), alarm + relay + audible-visual linkage (High)
- Protection Rating: IP65 (Low/Medium), IP67 (High)
6.11 Security System (Access Control & Cameras)
6.11.1 Access Control Terminal
- Identification Methods: Card + password (Low), fingerprint + card + password (Medium), face + fingerprint + card + password (High)
- Supported Doors: 1 door (Low), 2 doors (Medium), 4 doors (High)
- Extended Functions: Remote authorization (Medium), remote authorization + video linkage + permission grading + operation audit (High)
6.11.2 Network Camera
- Pixel Resolution: 2MP (Low), 4MP (Medium), 8MP (High)
- Video Resolution: 1080P (Low), 2K (Medium), 4K (High)
- Encoding Standard: H.265
- Functional Features: Infrared night vision, waterproof, motion detection (Medium/High), human shape recognition (High)
6.12 Integrated Cabling System (KITOZER-CAB Series)
- Twisted Pair Cable: Cat6 UTP (Low), Cat7 UTP (Medium), Cat8 shielded (High)
- Optical Fiber: OM3 multimode (Low), OM4 multimode (Medium), OM5 multimode (High)
- Cable Tray: Galvanized steel tray with cable managers
- Flame Retardant Grade: UL94-V0
- Cabling Mode: Unshielded (Low/Medium), full shielding + dedicated grounding (High)
6.13 Lighting System (KITOZER-LIT Series)
- Light Source: LED explosion-proof lamp
- Power Rating: 20W (Low), 30W (Medium), 50W (High)
- Operating Voltage: 220V
- Protection Rating: IP65
- Emergency Backup Runtime: 90min (Low), 180min (Medium), 240min (High)
- Intelligent Functions: Audible-visual linkage (Medium/High), stepless dimming (High)
7. Product Application Scope
7.1 Container Enclosure
- Edge Computing: 5G base station edge nodes, industrial internet edge computing deployment
- Disaster Recovery Centers: Enterprise off-site backup, data replication, emergency computing recovery
- Temporary Capacity Expansion: Short-term computing upgrade for data centers, project temporary deployment, exhibition demonstration
- Remote Sites: Mines, oil & gas, wind power, photovoltaic, water conservancy locations without dedicated civil computer rooms
- Special Environments: Chemical plants, coal mines, military facilities, explosion-proof & anti-corrosion hazardous sites
7.2 IT Rack
- Server Deployment: Rack servers, blade servers, high-density computing nodes
- Storage Equipment: Disk arrays, NAS, distributed storage nodes
- Network Hardware: Switches, routers, firewalls, load balancers
- High-density Computing: AI servers, GPU clusters, High Performance Computing (HPC) equipment
7.3 UPS Uninterruptible Power Supply
- IT Load Power Supply: Continuous power for servers, storage and network core equipment
- Precision Instruments: Medical devices, laboratory testing equipment, industrial automation voltage stabilization
- Emergency Power Backup: Prevent data loss and business interruption during mains power failure
- Harmonic Suppression: Improve power quality and protect precision hardware from grid fluctuations
7.4 Storage Battery Pack
- UPS Backup Power: Sustain power supply during mains outage to guarantee business continuity
- Off-grid Energy Storage: Power supply for remote sites without mains, backup for emergency lighting & monitoring
- Peak-Valley Power Regulation: Industrial & commercial energy storage to cut electricity costs under time-of-use pricing
7.5 Precision Power Distribution Cabinet
- Data Center Power Distribution: Centralized power supply, real-time monitoring and circuit protection for container data centers
- Industrial Power Distribution: Automated production lines, precision testing equipment, laboratory power distribution
- Building Weak Current Distribution: Office buildings, shopping malls, hotel IT equipment power supply
7.6 Rack PDU
- Intra-rack Power Supply: Power distribution for rack-mounted servers, switches and storage devices
- Remote O&M: Remote power switching, voltage/current monitoring and energy consumption statistics to reduce on-site maintenance
- Overload Protection: Avoid equipment damage caused by short circuit and overloading
7.7 Cooling System (Air / Liquid Cooling)
- Air Cooling: Low-density computer rooms, mild climate environments, medium & low power density rack heat dissipation
- Liquid Cooling: High-density computing rooms, AI GPU clusters, high-temperature outdoor sites with power density ≥10kW per rack
- Hybrid Cooling: Medium-high density scenarios balancing heat dissipation efficiency and project cost
7.8 Clean Agent Fire Suppression System
- Computer Room Fire Protection: Data centers, containerized computer rooms, server rooms and power distribution rooms
- Precision Equipment Rooms: Laboratories, instrument rooms with zero-residue fire suppression for delicate hardware
- Archives & Storage: Fire protection for confidential documents and high-value inventory
7.9 DCIM Monitoring Host
- Centralized Computer Room Monitoring: Real-time tracking of environmental parameters and equipment status for container data centers
- Unattended Remote O&M: Off-site monitoring, alarm notification and equipment control to cut labor costs
- Energy Management: Statistics and analysis of power consumption to optimize PUE indicators
7.10 Sensor Series
- Temperature & Humidity Monitoring: Computer rooms, equipment racks, warehouses and laboratory environmental tracking
- Water Leak Detection: Early warning for flooding risks in computer rooms, power distribution rooms and basements
- Industrial Environmental Monitoring: Real-time data collection for factory workshops, warehouses and greenhouses
7.11 Security System
- Computer Room Physical Security: Access control, video surveillance and intrusion detection for container data centers
- Factory & Campus Security: Entrance management and full-area monitoring for industrial parks and warehouses
- Commercial Building Security: Public area surveillance for offices, shopping malls and hotels
7.12 Integrated Cabling System
- Data Center Cabling: Strong & weak current wiring, high-speed network cabling for modular container facilities
- Building Integrated Wiring: Network coverage and structured cabling for office buildings and commercial complexes
- Industrial Cabling: Automation equipment wiring and industrial network construction for production workshops
7.13 Lighting System
- Computer Room Lighting: Daily operation and emergency evacuation lighting for modular data centers
- Industrial Explosion-proof Lighting: Production workshop and warehouse waterproof & explosion-proof lamps
- Outdoor Site Lighting: Waterproof lighting for industrial parks, roads and open yards
8. Product Competitive Advantages
8.1 Core Brand Advantages of KITOZER
- Customization Capability: Full-series personalized customization of enclosure size, technical parameters and functional modules according to site environment and power density requirements
- OEM & ODM Support: White-label manufacturing service for partners to build independent brands and lower procurement costs
- Confidentiality Agreement: Strict non-disclosure policy for customized schemes, technical data and client project information
- Fast Stock Delivery: Standard models in mass inventory; 20ft standard container data centers deliverable within 7 days for urgent projects
- One-stop Full Line Supply: Independent R&D and manufacturing covering enclosures, racks, UPS, cooling, fire suppression, monitoring and cabling; unified after-sales service with perfect cross-module compatibility
8.2 Container Enclosure Advantages
- Prefabricated Deployment: Factory pre-assembly and full testing, on-site deployment completed within 2–8 weeks without civil construction to shorten project cycle drastically
- Movable Flexibility: Standard ISO container dimensions support highway, railway and sea transportation for relocation between disaster recovery sites and temporary computing hubs
- Ultra-wide Environmental Adaptability: Stable operation at -40°C ~ +55°C, IP54+ protection against wind, rain, dust and corrosion for harsh outdoor industrial sites
- Low Full-lifecycle TCO: Eliminate investment in permanent computer room construction; liquid cooling design reduces PUE ≤1.2 to cut long-term energy consumption and maintenance costs
8.3 IT Rack Advantages
- High Load-bearing Capacity: 800–1,500kg maximum load to support stacked high-density GPU servers and storage arrays
- Hot & Cold Aisle Isolation: Mesh door + blanking panel design optimizes cold air circulation and improves cooling efficiency to reduce power consumption
- EMC Electromagnetic Shielding: Medium & high tiers provide Class A shielding to eliminate electromagnetic interference and stabilize hardware operation
- Universal Compatibility: Standard 19-inch mounting rails compatible with all mainstream server, storage and network equipment brands
8.4 UPS Uninterruptible Power Supply Advantages
- Ultra-high Reliability: Online double-conversion topology with 0ms switching; N+1/2N redundant architecture avoids single-point power failure
- Energy-saving High Efficiency: Online operation efficiency ≥94%–97%, ECO mode up to 99% to lower electricity expenses
- Wide Input Voltage Tolerance: ±15%~±20% mains input range to adapt to unstable power grids at remote industrial sites
- Intelligent Operation: Touch LCD panel supporting remote monitoring, parameter configuration and real-time fault alerts for easy unattended management
8.5 Storage Battery Pack Advantages
- Extended Service Life: Valve-regulated maintenance-free design with 5–10 year design life to reduce replacement frequency
- Wide Temperature Operation: Stable charge & discharge at -20°C ~ 50°C for extreme temperature outdoor container units
- Zero Daily Maintenance: Sealed construction eliminates regular water replenishment and reduces manual maintenance workload
- Stable Discharge Performance: Low internal resistance ensures consistent voltage output during UPS backup operation
8.6 Precision Power Distribution Cabinet Advantages
- Intelligent Energy Visualization: Real-time monitoring of voltage, current, power and harmonic distortion via touch LCD screen
- Multi-layer Safety Protection: Overload, short circuit, leakage and four-level lightning surge protection to guarantee power distribution safety
- Flexible Expansion: 12–24 output circuits to support incremental capacity expansion for computing clusters
- Human Safety Design: Insulated internal structure and anti-electric shock protection for maintenance personnel
8.7 Rack PDU Advantages
- Remote Intelligent Management: Medium & high tiers support remote power switching, real-time current monitoring and energy consumption statistics for unmanned computer rooms
- Multi-layer Surge Protection: Integrated lightning, overload and transient overvoltage protection to prevent sudden hardware damage
- Universal Compatibility: Standard Chinese national sockets compatible with mainstream IT equipment power cords worldwide
- Durable Construction: Aluminum alloy housing with high temperature and corrosion resistance for long service life
8.8 Cooling System Advantages
8.8.1 Air Cooling
- Simple Installation: No complex liquid piping required, low on-site construction and maintenance cost
- Energy-saving Variable Speed: Medium-tier EC variable-speed fans adjust airflow dynamically based on rack load to cut idle power draw
- Redundant Reliability: N+1 backup air conditioners ensure normal heat dissipation even if one unit fails
8.8.2 Liquid Cooling
- Superior Heat Dissipation Efficiency: Direct cold plate contact with GPU heat sources achieves PUE ≤1.2, ideal for ≥10kW per rack AI clusters
- Low Noise Operation: Closed liquid circulation reduces operating noise below 60dB for comfortable on-site maintenance
- High Temperature Resistance: Full-load stable operation at ambient temperatures up to 50°C for desert, mine and oilfield sites
8.9 Clean Agent Fire Suppression System Advantages
- Environmentally Friendly & Non-toxic: HFC-227ea/FK-5-1-12 agents leave no residue and do not corrode circuit boards or server hardware
- Rapid Fire Extinguishing: Automatic smoke/heat detection triggers instant discharge to suppress fires before hardware damage occurs
- Multi-mode Safety Activation: Auto/manual/emergency stop triple operation prevents accidental false discharge
8.10 DCIM Monitoring Host Advantages
- All-in-one Centralized Monitoring: Unified platform integrating temperature/humidity, water leakage, smoke, access control, UPS and air conditioner data
- Remote Unattended O&M: Off-site equipment status viewing and fault alert push to eliminate 24-hour on-site staffing
- 3D Visualization (High Tier): Intuitive panoramic display of container layout, rack load and equipment running status
- Multi-protocol Compatibility: RS485/SNMP/Modbus/HTTP support for seamless connection with upper-layer enterprise management platforms
8.11 Sensor Series Advantages
- Ultra-high Measurement Precision: Temperature accuracy ranging ±0.2°C~±0.5°C for reliable environmental data collection
- Wide Operating Temperature Range: Stable operation from -40°C ~ +80°C to fit all extreme deployment scenarios
- High Waterproof & Dustproof Grade: IP65/IP67 enclosure for long-term outdoor and corrosive industrial environment deployment
8.12 Security System Advantages
- Multi-dimensional Identity Authentication: Face/fingerprint/card/password multi-mode access control to upgrade physical security level
- Ultra-high Definition Surveillance: 4K cameras with infrared night vision and human shape detection for 24-hour all-weather monitoring
- Equipment Linkage Alarm: Interconnection between access control, cameras and alarm host to trigger instant notifications for abnormal intrusions
8.13 Integrated Cabling System Advantages
- High-speed Transmission Support: Cat8 shielded cable and OM5 fiber support 40G/100G data transmission to reserve bandwidth for future capacity expansion
- Fire-resistant Safety: UL94-V0 flame retardant standard to reduce fire spread risks inside the container
- Anti-interference Shielded Wiring (High Tier): Full shielding design eliminates electromagnetic crosstalk and stabilizes high-speed data signals
8.14 Lighting System Advantages
- Explosion-proof & Waterproof: IP65 rated LED lamps suitable for damp, dusty industrial and computer room environments
- Low Energy Consumption & Long Lifespan: LED light source with 50,000-hour service life to cut lamp replacement frequency
- Reliable Emergency Backup: 90–240 minutes of continuous lighting after power cut to support emergency inspection and equipment shutdown
9. Bid Tender Control Parameters (Marked with *)
9.1 Container Enclosure
- Material: High-strength Corten steel with five-sided fireproof rock wool insulation, protection rating *≥IP54
- Standard Size: 20ft (6058×2438×2896mm), customizable 10ft/40ft options available
- Disaster Resistance: Resists Category 12 typhoons, Magnitude 8 earthquake minimum *4. Operating Temperature Range: Stable long-term operation at -40°C ~ +55°C *5. Floor Load Capacity: ≥800kg/㎡ (Medium & High Tiers)
9.2 IT Rack
- Standard Size: 42U/47U 19-inch rack, medium tier dimension 600×1200×2000mm
- Load Capacity: ≥1,000kg (Medium & High Tiers)
- Door Panel: High-density mesh door with ventilation rate ≥75%
- Shielding Performance: Class A EMC shielding (High Tier only)
9.3 UPS Uninterruptible Power Supply
- Topology: Online double-conversion modular design
- Rated Capacity: ≥120kVA/108kW (Medium & High Tiers)
- Input Voltage: Three-phase 380V±15%, frequency 50/60Hz±3%
- Output Voltage: Three-phase 380V±0.5%, THDv ≤1% (Medium & High Tiers)
- Operating Efficiency: Online mode efficiency *≥96% (Medium & High Tiers) *6. Redundant Architecture: N+1 / 2N redundant design with automatic switching upon single unit failure
9.4 Storage Battery Pack
- Type: Maintenance-free lead-acid, capacity specification *≥150Ah@12V (Medium & High Tiers) *2. Operating Temperature: -10°C~45°C (Medium), -20°C~50°C (High) *3. Design Service Life: ≥8 years (Medium & High Tiers)
9.5 Precision Power Distribution Cabinet
*1. Rated Current: ≥120A (Medium & High Tiers) *2. Output Circuits: ≥16 independent output branches (Medium & High Tiers) *3. Protection Functions: Four-layer protection including overload, short circuit, leakage and lightning surge *4. Display Interface: Touch LCD screen for real-time power parameter visualization
9.6 Rack PDU
*1. Specification: ≥16 outlets, 32A rated current, 220V/380V dual input support *2. Protection Mechanism: Triple protection of lightning surge, overload and transient overvoltage *3. Remote Management: Support remote power switching, real-time current monitoring and energy consumption statistics (Medium & High Tiers)
9.7 Cooling System
9.7.1 In-row Air Conditioner
- Single-unit Cooling Capacity: ≥50kW (Medium Tier)
- Temperature & Humidity Control: 18–28°C, 40%–60% RH, precision ±0.5°C *3. Protection Rating: ≥IP54 *4. Redundant Design: N+1 backup with EC variable-speed fans
9.7.2 Liquid Cooling CDU Unit
*1. Total Cooling Capacity: ≥100kW *2. Pump System: Dual redundant pumps with automatic failure switching *3. Temperature Difference Control Accuracy: ±0.5°C *4. Protection Rating: ≥IP54
9.8 Clean Agent Fire Suppression System
*1. Extinguishing Agent: HFC-227ea or FK-5-1-12 clean agent, non-toxic and residue-free *2. Tank Volume: ≥90L (Medium & High Tiers) *3. Activation Mode: Triple control of automatic, manual and emergency stop
9.9 DCIM Monitoring Host
- Hardware Form Factor: 19-inch rack-mounted unit *≥2U height (Medium & High Tiers) *2. Monitoring Channel Quantity: ≥8 temp/humidity + 4 water leakage + 2 smoke sensor channels (Medium & High Tiers) *3. Communication Protocols: Support SNMP & Modbus industrial protocols (Medium & High Tiers) *4. Display Terminal: ≥10-inch touch screen, 3D panoramic visualization supported (High Tier)
9.10 Sensor Series
*1. Temperature Measurement Accuracy: ±0.3°C (Medium), ±0.2°C (High) *2. Operating Temperature Range: -30°C~+70°C (Medium), -40°C~+80°C (High) *3. Protection Rating: ≥IP65 (Medium), ≥IP67 (High)
9.11 Security System
*1. Access Control Recognition: Face + fingerprint + card + password four-in-one identification (High Tier) *2. Camera Pixel Resolution: ≥4MP (Medium), ≥8MP (High) *3. Core Camera Functions: Infrared night vision, motion detection and human shape recognition
9.12 Integrated Cabling System
*1. Twisted Pair Standard: Cat7 UTP (Medium), Cat8 shielded (High) *2. Optical Fiber Standard: OM4 multimode (Medium), OM5 multimode (High) *3. Flame Retardant Standard: UL94-V0
9.13 Lighting System
- Light Source: LED explosion-proof lamp, rated power *≥30W (Medium & High Tiers) *2. Protection Rating: ≥IP65 *3. Emergency Backup Runtime: ≥180 minutes (Medium & High Tiers)
10. Customized Solution Packages
10.1 Edge Computing Container Data Center Solution
- Core Demand: Low-latency computing deployment for 5G edge nodes and industrial internet without permanent civil computer rooms
- Recommended Configuration: 20ft medium-tier container, 4–6 medium-density racks, 120kVA UPS, 50kW in-row air conditioners, DCIM centralized monitoring, HFC-227ea fire suppression
- Solution Strengths: 7-day rapid delivery, relocatable design, ultra-wide environmental adaptability, low network latency for outdoor edge sites
- Typical Scenarios: 5G communication base stations, smart factories, intelligent manufacturing, IoT cloud platforms
10.2 AI High-density Computing Container Data Center Solution
- Core Demand: AI model training, GPU cluster operation, high-performance computing with power density ≥10kW per rack and high-temperature outdoor environments
- Recommended Configuration: 40ft high-tier container, 12 high-density racks, dual 200kVA UPS, four 100kW liquid cooling CDU units, closed cooling towers, 3D visualized DCIM, FK-5-1-12 fire suppression
- Solution Strengths: High-efficiency liquid cooling with PUE ≤1.2, 2N full power redundancy, stable full-load operation at 50°C ambient temperature, 30% energy consumption reduction for GPU clusters
- Typical Scenarios: AI training bases, autonomous driving computing, big data analysis, HPC high-performance computing
10.3 Off-site Disaster Recovery Container Data Center Solution
- Core Demand: Enterprise cross-region data backup, emergency business recovery, rapid service switching and data security guarantee
- Recommended Configuration: 20ft medium-tier container, 4 medium-density racks, 120kVA UPS, 50kW in-row air conditioners, DCIM remote monitoring, HFC-227ea fire suppression, dual mains + generator redundant power supply
- Solution Strengths: Ultra-short deployment cycle, movable for disaster site switching, full data security protection, business recovery within 1 hour after primary site failure
- Typical Scenarios: Financial institutions, government agencies, medical groups, enterprise headquarters off-site backup
10.4 Remote Industrial Site Container Data Center Solution
- Core Demand: Unattended operation for mines, oil & gas fields, wind farms and hydropower stations without stable mains power supply
- Recommended Configuration: 10ft low-tier / 20ft medium-tier container, 2–4 racks, 60–120kVA UPS, battery pack + photovoltaic complementary power supply, 30–50kW air conditioners, DCIM remote cloud monitoring
- Solution Strengths: Off-grid power support, 24/7 unattended operation, strong resistance to extreme low/high temperatures, suitable for infrastructure-free remote industrial zones
- Typical Scenarios: Open-pit mines, offshore oil platforms, wind power plants, photovoltaic power stations, water conservancy hubs
10.5 Explosion-proof & Anti-corrosion Container Data Center Solution
- Core Demand: Safe IT deployment in flammable, explosive and corrosive chemical, coal and military environments
- Recommended Configuration: 20ft medium-tier / 40ft high-tier container, explosion-proof enclosure with heavy anti-corrosion coating, explosion-proof racks, explosion-proof UPS & air conditioners, explosion-proof fire suppression and monitoring systems
- Solution Strengths: IP65 explosion-proof & anti-corrosion rating, intrinsic safety design to eliminate ignition risks in hazardous atmospheres
- Typical Scenarios: Chemical industrial parks, underground coal mines, military bases, offshore oil & gas platforms
11. Project Application Cases
11.1 Edge Computing Project for National 5G Operator
- Project Scale: 10 sets of 20ft medium-tier container data centers deployed across 5 provincial edge node zones
- Core Configuration: 6 medium-density racks per unit, 120kVA UPS, 50kW in-row air conditioners, DCIM monitoring, HFC-227ea fire suppression
- Project Outcome: Single unit deployed within 7 days, supports 5G edge computing and industrial IoT services with end-to-end latency controlled under 10ms; zero failure during 2 years of continuous operation
11.2 High-density AI Computing Project for Artificial Intelligence Enterprise
- Project Scale: 5 sets of 40ft high-tier liquid-cooled container data centers for AI training base
- Core Configuration: 12 high-density racks per unit, dual 200kVA UPS, four 100kW CDU liquid cooling units, closed cooling towers, 3D DCIM monitoring, FK-5-1-12 fire suppression
- Project Outcome: Single rack power density reaches 15kW, PUE controlled below 1.18; stable full-load operation under 50°C ambient temperature, overall computing cluster energy consumption reduced by 30%
11.3 Off-site Disaster Recovery Project for Financial Enterprise
- Project Scale: 2 sets of 20ft medium-tier container data centers deployed at remote backup site
- Core Configuration: 4 medium-density racks per unit, 120kVA UPS, 50kW in-row air conditioners, DCIM monitoring, HFC-227ea fire suppression, dual mains + standby generator
- Project Outcome: Full project delivered within 15 days, real-time core business data replication and emergency switching realized; service recovery time ≤1 hour to guarantee 7×24-hour uninterrupted financial transactions
11.4 Remote Wind Farm Industrial Site Project for Energy Group
- Project Scale: 8 sets of 10ft low-tier container data centers distributed across remote wind farm sites
- Core Configuration: 2 racks per unit, 60kVA UPS, lead-acid battery pack + photovoltaic complementary power supply, 30kW air conditioners, cloud-based DCIM remote monitoring
- Project Outcome: Stable off-grid unattended operation to support wind farm data collection and equipment monitoring; continuous trouble-free operation for 3 years under -30°C ~ +45°C fluctuating temperatures
11.5 Explosion-proof Anti-corrosion Project for Chemical Manufacturer
- Project Scale: 3 sets of 20ft medium-tier explosion-proof container data centers deployed inside chemical industrial park
- Core Configuration: 4 explosion-proof racks per unit, 120kVA explosion-proof UPS, 50kW explosion-proof air conditioners, explosion-proof fire suppression and monitoring systems
- Project Outcome: IP65 explosion & corrosion resistance adapts to chemical volatile corrosive and flammable environments; stable data processing and production monitoring for 2 years without safety incidents
12. Common Faults & Maintenance Guidelines
12.1 Container Enclosure
Common Faults
- Water leakage: Aging sealant, damaged waterproof eaves, cracked welding seams
- Anti-corrosion coating peeling: Long-term corrosive environment, coating aging, collision damage
- Door frame deformation: Overweight stacking, typhoon impact, loose hinge fasteners
Maintenance Schedule
- Daily Inspection (Weekly): Check sealant, waterproof eaves, welding seams and anti-corrosion coating; clear dust and debris on enclosure surface
- Quarterly Maintenance: Inspect anti-corrosion coating, touch up peeled areas with anti-rust paint; tighten door hinge screws and add lubricating oil
- Annual Overhaul: Full structural inspection of frame and welding seams; reinforce loose components and fully repair anti-corrosion coating
12.2 IT Rack
Common Faults
- Rack frame deformation: Overweight load, transportation collision, uneven installation ground
- Mesh door damage: Impact collision, rust corrosion, broken hinge
- Cable manager looseness: Cable pulling force, loose mounting screws
Maintenance Schedule
- Daily Inspection (Weekly): Check rack appearance, door operation and cable managers; remove accumulated dust inside rack
- Quarterly Maintenance: Verify rack horizontal level and load balance, tighten all mounting screws; lubricate door locks and hinges
- Annual Overhaul: Full inspection of rack welding points and EMC shielding layers; reinforce loose brackets and touch up anti-rust coating
12.3 UPS Uninterruptible Power Supply
Common Faults
- Instant shutdown after mains failure: Degraded battery capacity, loose wiring terminals, faulty charging circuit
- Unstable output voltage: Abnormal mains input, overloaded load, damaged inverter module
- Excessive fan noise / fan stall: Dust blockage, bearing wear, faulty fan motor
Maintenance Schedule
- Daily Inspection: Check UPS running status, voltage, current, internal temperature and fan operation; review fault alarm logs
- Quarterly Maintenance: Clean internal dust, inspect and tighten power wiring terminals; test battery voltage and internal resistance, verify backup runtime
- Annual Overhaul: Full performance test of rectifier, inverter, capacitors and fans; replace aging spare parts and calibrate operational parameters
12.4 Storage Battery Pack
Common Faults
- Severe capacity attenuation: Long-term aging, frequent overcharge/over-discharge, extreme operating temperature
- Electrolyte leakage: Shell aging, loose sealing, transportation collision
- Battery swelling: Overcharging, internal short circuit, high ambient temperature
Maintenance Schedule
- Daily Inspection: Check battery surface appearance, terminal voltage and temperature; monitor for leakage or swelling
- Quarterly Maintenance: Measure single cell voltage and internal resistance, wipe surface dust; conduct full charge-discharge test every six months to calibrate actual capacity
- Annual Overhaul: Inspect battery connecting wires and terminals, tighten loose fasteners; replace severely degraded batteries
12.5 Precision Power Distribution Cabinet
Common Faults
- Frequent circuit breaker tripping: Overload, short circuit, leakage current, failed surge protector
- Abnormal power meter readings: Damaged current/voltage sensor, poor wiring contact, broken display screen
- Overheating terminals: Loose screws, oxidized cable terminals, long-term overload
Maintenance Schedule
- Daily Inspection: Check cabinet operating status, voltage/current readings and internal temperature; review fault alarms
- Quarterly Maintenance: Clean internal dust, tighten all cable terminals; test circuit breakers and surge protection performance every six months
- Annual Overhaul: Calibrate power sensors and touch screens; replace aging breakers and surge protectors
12.6 Rack PDU
Common Faults
- No power output: Mains input cut-off, blown fuse, internal circuit breakage
- Failed remote control function: Network disconnection, damaged communication module, incorrect parameter settings
- Severe overheating: Overloaded load, loose socket terminals, oxidized wiring
Maintenance Schedule
- Weekly Inspection: Check PDU appearance, indicator lights and surface temperature; inspect plug connection tightness
- Quarterly Maintenance: Clean surface dust, tighten socket terminals; test remote power switch and overload protection functions every six months
- Annual Overhaul: Inspect internal circuits, communication modules and fuses; replace aging PDUs with degraded performance
12.7 Cooling System (Air / Liquid Cooling)
Common Faults
- Insufficient cooling capacity: Blocked air filter, fouled condenser, refrigerant leakage, failed fan
- Excessive operating noise: Worn fan bearings, loose pipeline fixing brackets, damaged compressor
- Internal water leakage: Blocked drain pipe, cracked condensate tray, loose pipeline joints
Maintenance Schedule
- Daily Inspection: Monitor air conditioner/CDU operating status, temperature, pressure and pipeline tightness; check for water leakage and fault alarms
- Monthly Maintenance: Clean air filter and condenser heat exchanger; inspect refrigerant pressure and pipeline joints quarterly, replenish refrigerant as required; lubricate fan bearings every six months
- Annual Overhaul: Full inspection of compressors, fans, pipelines and valves; replace aging components and calibrate temperature control parameters
12.8 Clean Agent Fire Suppression System
Common Faults
- Failure to discharge upon fire alarm: Power failure, broken signal wiring, insufficient pressure in starter cylinder
- False fire alarm: Malfunctioning smoke/heat detectors, dust interference, short-circuited signal cables
- Low cylinder pressure: Agent leakage, loose valve seal, damaged pressure gauge
Maintenance Schedule
- Weekly Inspection: Check fire suppression unit appearance, cylinder pressure, power supply and signal wiring; review alarm logs
- Quarterly Maintenance: Test smoke/heat detector sensitivity and alarm host function, clean detector dust; inspect starter cylinder pressure and agent weight every six months, replenish agent as required
- Annual Overhaul: Full functional test of activation mechanism, pipelines and discharge nozzles; verify full equipment linkage performance and replace aging accessories
12.9 DCIM Monitoring Host
Common Faults
- Interrupted monitoring signal: Network failure, host crash, damaged sensor
- Abnormal collected data: Drifted sensor calibration, electromagnetic signal interference, software bug
- Failed alarm notification: Damaged alarm module, incorrect threshold settings, network delay
Maintenance Schedule
- Daily Inspection: Check host running status, network connection and real-time sensor data; review historical alarm records
- Quarterly Maintenance: Clean internal dust, tighten signal wiring terminals; calibrate sensor parameters and back up monitoring database every six months
- Annual Overhaul: Full hardware and software inspection of host and sensors; replace aging hardware and upgrade monitoring software version
12.10 Security System
Common Faults
- Access control door unlock failure: Power cut, damaged card/fingerprint reader, faulty electromagnetic lock, incorrect access permissions
- No camera video output: Power failure, network disconnection, dirty lens, broken camera module
- No alarm trigger: Malfunctioning intrusion detector, broken signal cable, wrong alarm threshold settings
Maintenance Schedule
- Weekly Inspection: Check access control terminals, cameras and detectors for physical damage, power supply and wiring; clean camera lens dust
- Quarterly Maintenance: Test access recognition accuracy, camera imaging quality and detector sensitivity; lubricate door locks and tighten mounting brackets every six months
- Annual Overhaul: Full functional test of all security equipment; replace aging cameras, readers and detectors
13. Search Keywords & SEO Tag System
13.1 Keyword Hierarchy
- Core Primary Keywords Container data center, modular container data center, prefabricated data center, outdoor integrated computer room, edge computing container data center
- High-conversion Long-tail Keywords KITOZER container data center manufacturer, 20ft container data center, 40ft high-density container data center, liquid cooling container data center, explosion-proof anti-corrosion container data center, UPS integrated container data center, AI computing container data center
- Industry Traffic Keywords Prefabricated modular data center, mobile data center, temporary capacity expansion data center, outdoor integrated rack, edge data center, closed hot/cold aisle container data center
- Brand Exclusive Keywords Laian Intelligent container data center, KITOZER data center, Laian prefabricated computer room, KITOZER integrated computer room, Guangzhou Laian container data center
- Drop-down & Related Search Keywords Container data center price, standard dimensions of container data center, container data center installation specifications, top container data center manufacturers, PUE value of container data center, difference between container and traditional data center
13.2 SEO Optimization Tag System
- Core Page Tags Page Theme: KITOZER Container Data Center Solution Core Keywords: Container data center, modular data center, prefabricated computer room Page Type: Product Solution Detail Page Official Website: gdlain.com
- Title Tag KITOZER Container Data Center | Modular Prefabricated Integrated Computer Room Solution – Guangzhou Laian Intelligent
- Meta Keywords Container data center, modular data center, prefabricated data center, outdoor integrated computer room, edge computing container data center, KITOZER container data center, Guangzhou Laian Intelligent
- Meta Description Guangzhou Laian Intelligent Systems Development Co., Ltd. provides KITOZER container data center solutions, including 20ft/40ft prefabricated units, air/liquid cooling, high-density and explosion-proof outdoor integrated computer rooms. Custom OEM & ODM services, rapid on-site deployment nationwide. Hotline: +86 +86 13509238849.
- H1 Tag KITOZER Container Data Center Solution
- H2 Tag List
- Overview of Container Data Center System
- Composition & Classification of Container Data Center Systems
- System Principle Diagrams
- Low/Medium/High Tier Full Configuration List (KITOZER)
- Product Technical Specifications & Application Scope
- Product Advantages & Bid Control Parameters
- Targeted Solutions & Real Project Cases
- Common Faults & Maintenance Guidelines
- Factory Capacity & After-sales Service
- Internal Link Anchor Text
- Core Anchors: Container data center, modular data center, prefabricated computer room
- Long-tail Anchors: KITOZER container data center manufacturer, outdoor integrated container data center, liquid cooling container data center
- Related Anchors: UPS uninterruptible power supply, precision power distribution cabinet, in-row air conditioner, DCIM monitoring system, clean agent fire suppression system