Table of Contents
Toggle1. System Overview
KITOZER network isolation equipment is a professional security device developed to meet core demands of secure data transmission and network boundary protection. Focusing on cross-domain secure data exchange, network boundary isolation, server and terminal protection scenarios, it adopts core technologies including physical isolation, one-way transmission and protocol stripping to build an isolation protection system featuring “physically disconnected links, logically controllable access and fully secure data”. It effectively defends against cyberattacks, data leakage and malicious intrusions, complies with Classified Protection of Cybersecurity Version 2.0 and classified protection standards for confidential information systems, and is widely deployed in critical sectors including government, military industry, finance, electric power and industrial control. It delivers highly reliable and secure isolation guarantee for data interaction between networks of different security levels, serving as an indispensable core device in network security protection systems.

KITOZER Network Isolation Device
2. System Composition
The KITOZER network isolation system consists of seven core modules: core isolation unit, protocol processing unit, data exchange unit, security audit unit, management control unit, power supply protection unit and interface expansion unit. All modules work in coordination to realize full-process controllability of isolation, data exchange, protection and management:
- Core Isolation Unit: The core component of the system, adopting physical isolation chips or optical isolation modules to physically disconnect internal and external network links and block direct network connections. It supports two isolation modes: electronic switch and optical signal transmission, with a maximum isolation voltage of 4000V, ensuring no direct communication at the network layer.
- Protocol Processing Unit: Responsible for parsing, stripping and reconstructing protocols. It supports mainstream protocols such as TCP/IP, Modbus, Profinet and OPC UA, filters malicious protocol fields, only permits legitimate protocol data to pass through, and blocks abnormal protocol attacks.
- Data Exchange Unit: Enables controllable cross-network data transfer, supporting transmission of multiple data types including files, databases, videos and instructions. It integrates data integrity verification via SM3 national cryptographic algorithm, data desensitization and keyword filtering to guarantee secure and compliant exchanged data.
- Security Audit Unit: Records full logs of data exchange, operations and alarms, with log retention period ≥ 180 days. It supports log query, export and audit analysis to meet compliance traceability requirements, and triggers real-time alarms upon abnormal behavior detection.

Schematic Drawing of KITOZER Isolation Equipment
- Management Control Unit: Provides multiple management accesses including WEB, CLI and serial port, supporting device configuration, policy management, permission control and remote upgrade. It implements three-level permission separation for administrators, operators and auditors to secure device management.
- Power Supply Protection Unit: Adopts industrial wide-voltage power supply (DC 9-36V / AC 100-240V) with overvoltage, overcurrent, short-circuit and lightning protection. Dual power redundancy backup is available to adapt to complex power supply environments and ensure 7×24-hour stable device operation.
- Interface Expansion Unit: Equipped with abundant interfaces including RJ45 Ethernet ports, optical ports (single-mode/multi-mode), RS485/232 serial ports, USB ports and Console ports. Customizable interface expansion is supported to adapt to diverse network topologies and equipment connection requirements.
3. System Classification
KITOZER network isolation equipment is categorized from four dimensions: isolation technical principle, application scenario, security level and transmission rate, covering full-range isolation demands. Detailed classifications are as follows:
3.1 Classification by Isolation Technical Principle
- Physical Isolation Gateway (GAP) Adopts a “dual-host + isolation component” architecture, achieving physical disconnection between internal and external networks via electronic switches. Data is transferred through a “cache-inspection-forward” workflow. Security Level: ★★★★★. Applicable to isolation between confidential and non-confidential networks, internal and external networks.
- One-way Data Diode Based on one-way optical signal transmission technology with separated TX/RX optical modules, enabling data to flow only from low-security domains to high-security domains with zero feedback channels. Security Level: ★★★★☆. Applicable to industrial control, meteorological data collection and one-way import of confidential data.
- Terminal Isolation Card Single/dual motherboard architecture controlling hard disk and network card switching via isolation cards to realize dual-network isolation on a single terminal device. Security Level: ★★★☆☆. Applicable to dual-network switching for office and confidential terminals.
- Protocol Isolation Gateway Implements logical isolation through customized protocol stripping and filtering on physically connected networks. Security Level: ★★★☆☆. Applicable to isolation of different business systems within the same security domain and industrial protocol protection.
- Network Isolator Uses optocoupler technology to realize electrical isolation of network interfaces, eliminating ground loop currents and resisting lightning strikes. Security Level: ★★☆☆☆. Applicable to electrical isolation between devices and anti-interference for industrial networks.
3.2 Classification by Application Scenario

KITOZER Production Workshop
- Government/Military-Grade Isolation Equipment: Adapted to confidential information systems and e-government networks, supporting national cryptographic algorithms and classified protection with the highest security level.
- Industrial Control-Grade Isolation Equipment: Adapted to power, chemical and intelligent manufacturing industrial control networks, supporting industrial protocols (Modbus, Profinet) with low latency and high stability.
- Financial-Grade Isolation Equipment: Adapted to banking, securities and insurance systems, supporting transaction data desensitization, SWIFT message filtering and high-concurrency transmission.
- Enterprise/Office-Grade Isolation Equipment: Adapted to isolation between corporate intranets and the Internet, office networks and business networks, featuring cost-effectiveness and convenient deployment.
3.3 Classification by Security Level (Low / Medium / High)
- Entry Level (Low Security): Network isolators and basic terminal isolation cards, isolation voltage ≤2500V, transmission rate ≤100Mbps. For non-confidential scenarios with low security requirements.
- Enterprise Level (Medium Security): Standard physical isolation gateways and industrial protocol isolation gateways, isolation voltage 2500-3500V, transmission rate 100-1000Mbps. For corporate intranet isolation and protection of non-core industrial systems.
- Confidential Level (High Security): One-way data diodes and high-end physical isolation gateways, isolation voltage ≥3500V, transmission rate ≥1000Mbps, supporting national cryptographic algorithms and one-way zero feedback. For confidential networks, military industry and core power systems.
4. System Schematic Diagrams
4.1 Physical Isolation Gateway (GAP) Schematic
Low-Security External Network ↔ External Host (Protocol Stripping / Data Receiving) ↔ Isolation Component (Electronic Switch / Physical Disconnection) ↔ Internal Host (Protocol Reconstruction / Data Forwarding) ↔ High-Security Internal Network
↑
Security Audit Unit (Log Recording / Alarm Triggering)
↑
Management Control Unit (Configuration / Policy / Permission Management)
4.2 One-way Data Diode Schematic
Transmitting End (Low-Security Domain) → Optical Transmitting Module (TX) → Optical Splitter → Optical Receiving Module (RX) → Receiving End (High-Security Domain)
↑
Control & Audit Unit (Status Monitoring / Log Storage)
4.3 Terminal Isolation Card Schematic
External Network Hard Disk / Network Card ↔ Isolation Card (Switch Control) ↔ Motherboard ↔ Internal Network Hard Disk / Network Card
↑
Switch Control Module (Manual / Automatic Switching)

Field Installation of KITOZER Equipment
5. System Configuration List (Entry / Enterprise / Confidential Grade, Brand: KITOZER)
5.1 Entry-Grade Configuration List (Low Security Demand)

Entry-Grade KITOZER Devices
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Network Isolator | KITOZER-NI-100 | 1. Interface: 10/100Mbps RJ45 ×2; 2. Isolation Voltage: 2500Vrms; 3. Transmission Rate: 100Mbps; 4. Bit Error Rate: <10⁻⁹; 5. Power Supply: DC 5V/1A; 6. Dimension: 120×80×30mm; 7. Operating Temp: -10℃~55℃ | 1 | Unit | KITOZER | Desktop, plug-and-play with zero configuration |
| 2 | Basic Terminal Isolation Card | KITOZER-IC-100 | 1. Architecture: Single motherboard with dual hard disks; 2. Interfaces: SATA ×2, RJ45 ×2; 3. Switch Mode: Manual button switching; 4. Isolation Voltage: 2500V; 5. Supported OS: Windows 7/10/11; 6. Dimension: 120×60×20mm | 1 | Piece | KITOZER | Compatible with desktops for dual-network switching |
| 3 | Industrial Power Module | KITOZER-PW-100 | 1. Input: AC 100-240V; 2. Output: DC 5V/2A; 3. Protection: Overvoltage, overcurrent, short-circuit protection; 4. Dimension: 80×50×25mm | 1 | Unit | KITOZER | Power supply for isolators & isolation cards |
| 4 | Debug Serial Cable | KITOZER-CAB-001 | 1. Interface: RS232/USB; 2. Length: 1.5m; 3. Baud Rate: 9600-115200bps | 1 | Piece | KITOZER | For equipment debugging & configuration |
5.2 Enterprise-Grade Configuration List (Medium Security Demand)
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Standard Physical Isolation Gateway | KITOZER-GAP-1000 | 1. Architecture: Dual-host with electronic switch isolation component; 2. Interfaces: 10/100/1000Mbps RJ45 ×4, Console ×2; 3. Isolation Voltage: 3000Vrms; 4. Transmission Rate: 1000Mbps; 5. Supported Protocols: TCP/IP, FTP, HTTP, Modbus; 6. Data Verification: SM3 National Cryptographic Algorithm; 7. Log Storage: 128GB; 8. Power Supply: AC 100-240V, dual power redundancy; 9. Dimension: 440×280×44mm (1U rackmount); 10. Operating Temp: -20℃~60℃ | 1 | Unit | KITOZER | Isolation between corporate intranet and internet, supporting controllable data exchange |
| 2 | Industrial Protocol Isolation Gateway | KITOZER-PG-500 | 1. Interfaces: 1000Mbps RJ45 ×2, RS485 ×2; 2. Isolation Voltage: 3000V; 3. Transmission Rate: 500Mbps; 4. Supported Protocols: Modbus RTU/TCP, Profinet, OPC UA; 5. Protocol Filtering: Malicious field stripping & whitelist control; 6. Power Supply: DC 9-36V; 7. Dimension: 200×150×50mm | 1 | Unit | KITOZER | Isolation between industrial control and office networks, industrial protocol protection |
| 3 | Enterprise Terminal Isolation Card | KITOZER-IC-500 | 1. Architecture: Dual motherboard with dual hard disks; 2. Interfaces: SATA ×4, RJ45 ×2, USB ×2; 3. Switch Mode: Manual / remote software switching; 4. Isolation Voltage: 3000V; 5. Supported OS: Windows 7/10/11, Linux; 6. Security Feature: Hard disk encryption; 7. Dimension: 150×80×25mm | 1 | Piece | KITOZER | Dual-network isolation for confidential office terminals, remote switching supported |
| 4 | Redundant Power Module | KITOZER-PW-500 | 1. Input: AC 100-240V; 2. Output: DC 12V/5A; 3. Redundancy: Automatic dual-power switching; 4. Protection: Overvoltage, overcurrent, short-circuit, lightning protection; 5. Dimension: 220×120×50mm | 2 | Unit | KITOZER | Dedicated for gateways to ensure stable power supply |
| 5 | Security Audit Module | KITOZER-AUD-500 | 1. Log Storage: 512GB; 2. Log Retention: ≥180 days; 3. Audit Functions: Data exchange, operation & alarm audit; 4. Interfaces: RJ45 ×1, USB ×2; 5. Form Factor: 1U rackmount | 1 | Unit | KITOZER | Log storage & audit analysis for isolation gateways |
| 6 | Rackmount Installation Kit | KITOZER-ACC-002 | 1. Material: Cold-rolled steel; 2. Compatibility: 19-inch standard rack; 3. Contents: Mounting ears, screws, fixing brackets | 1 | Set | KITOZER | Rack installation for gateways |
5.3 Confidential-Grade Configuration List (High Security Demand)
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Confidential-Grade One-way Data Diode | KITOZER-DD-10G | 1. Transmission Principle: One-way optical signal transmission (separated TX/RX); 2. Interfaces: 10Gbps single-mode optical ports ×2, RJ45 ×2, Console ×1; 3. Isolation Voltage: 4000Vrms; 4. Transmission Rate: 10Gbps; 5. One-way Characteristic: Zero feedback channel, data only transmitted from low to high security domain; 6. Supported Protocols: TCP/IP, database sync, file transfer, industrial protocols; 7. Security Features: SM3/SM4 national cryptography, data desensitization, keyword filtering; 8. Bit Error Rate: <10⁻¹²; 9. Log Storage: 1TB; 10. Power Supply: AC 100-240V, dual power redundancy; 11. Dimension: 2U rackmount; 12. Operating Temp: -25℃~70℃ | 1 | Unit | KITOZER | One-way data import between confidential and non-confidential networks, dedicated for government & military industry |
| 2 | High-End Confidential Physical Isolation Gateway | KITOZER-GAP-10G | 1. Architecture: Dual-host with optical isolation components; 2. Interfaces: 10Gbps single-mode optical ports ×4, RJ45 ×4, Console ×2, USB ×4; 3. Isolation Voltage: 4000V; 4. Transmission Rate: 10Gbps; 5. Protocol Support: Full protocol parsing & stripping, national cryptographic encryption supported; 6. Data Exchange: Controllable bidirectional transfer of files, databases, videos and instructions; 7. Security Features: ≥10Gbps DDoS resistance, intrusion detection, malicious code filtering; 8. Log Storage: 1TB, audit retention ≥365 days; 9. Power Supply: Hot redundant dual power, remote power management; 10. Dimension: 2U rackmount; 11. Certifications: Cybersecurity Class 3, Confidential Information System Certification, National Cryptography Authority Certification | 1 | Unit | KITOZER | Bidirectional secure data exchange for high-security domains, dedicated for core government & financial systems |
| 3 | Military-Grade Terminal Isolation Card | KITOZER-IC-1000 | 1. Architecture: Dual motherboard, dual hard disk & dual network card high-security isolation architecture; 2. Interfaces: SATA ×4, RJ45 ×4, USB ×4, HDMI ×2; 3. Switch Mode: Hardware button / software / centralized remote control; 4. Isolation Voltage: 4000V; 5. Encryption: SM4 national cryptographic hard disk encryption, transmission encryption; 6. Security: Information leakage prevention, illegal switching interception, operation log audit; 7. Supported OS: Windows, Linux, domestic operating systems; 8. Dimension: 200×100×30mm | 1 | Piece | KITOZER | High-security dual-network isolation for military & confidential terminals |
| 4 | National Cryptography Encryption Module | KITOZER-ENC-1000 | 1. Supported Algorithms: SM1/SM2/SM3/SM4 national cryptographic algorithms; 2. Interfaces: PCIe ×1, USB ×2; 3. Encryption Speed: 10Gbps; 4. Functions: Data transmission encryption, storage encryption, identity authentication; 5. Certification: National Cryptography Authority certified | 1 | Unit | KITOZER | Encryption for gateways & data diodes, compliant with confidential standards |
| 5 | Military-Grade Redundant Power Supply | KITOZER-PW-1000 | 1. Input: AC 85-264V wide voltage; 2. Output: DC 12V/10A; 3. Redundancy: Hot backup dual power, millisecond-level switchover; 4. Protection: Overvoltage, overcurrent, short-circuit, lightning & surge protection; 5. Operating Temp: -40℃~85℃; 6. Certification: Military standard certification | 2 | Unit | KITOZER | Dedicated for high-security equipment, stable power supply under extreme environments |
| 6 | Centralized Management Platform | KITOZER-MGT-1000 | 1. Deployment: Rackmount hardware / server software deployment (optional); 2. Managed Devices: Supports centralized control of ≥100 isolation devices; 3. Functions: Device configuration, policy distribution, permission management, centralized log audit, unified alarm management, remote upgrade; 4. Interfaces: RJ45 ×4, USB ×2, HDMI ×1; 5. OS: Domestic Linux operating system | 1 | Set | KITOZER | Centralized control of multiple isolation devices to simplify operation & maintenance |
| 7 | Military-Grade Installation Kit | KITOZER-ACC-005 | 1. Material: High-strength alloy; 2. Compatibility: 19-inch standard rack; 3. Protection: Corrosion & vibration resistance; 4. Contents: Mounting ears, shockproof brackets, fixing screws | 1 | Set | KITOZER | Rack installation for military-grade equipment, adapting to harsh environments |
6. Full Product Technical Specifications

Rack Installation of KITOZER 1U Gateway
6.1 KITOZER-NI-100 Network Isolator Specifications
- Hardware Interfaces: 2×10/100Mbps adaptive RJ45 Ethernet ports, 1×DC 5V power port
- Isolation Performance: 2500Vrms isolation voltage, complete electrical isolation to eliminate ground loop currents
- Transmission Performance: 100Mbps transmission rate, bit error rate <10⁻⁹, full-duplex/half-duplex supported
- Power Supply: DC 5V/1A, low power consumption ≤5W
- Environmental Parameters: Operating temp -10℃~55℃, storage temp -20℃~70℃, relative humidity 10%-90% (non-condensing)
- Physical Parameters: Dimension 120×80×30mm, weight 0.5kg, desktop installation, anti-static metal enclosure
6.2 KITOZER-IC-100/500/1000 Terminal Isolation Card Specifications
6.2.1 KITOZER-IC-100 (Entry Grade)

Command Center Deployment
- Hardware Architecture: Single motherboard with dual hard disk isolation architecture
- Interfaces: 2×SATA hard disk ports, 2×RJ45 network ports, 1×switch button
- Isolation Performance: 2500V isolation voltage, electrical isolation between internal and external networks
- Switch Mode: Manual button switching, switching time ≤3s
- Supported OS: Windows 7/10/11 (32/64-bit)
- Physical Parameters: Dimension 120×60×20mm, weight 0.3kg, PCIe slot installation
6.2.2 KITOZER-IC-500 (Enterprise Grade)
- Hardware Architecture: Dual motherboard with dual hard disk isolation architecture
- Interfaces: 4×SATA hard disk ports, 2×RJ45 network ports, 2×USB ports, remote switching supported
- Isolation Performance: 3000V isolation voltage, anti-information leakage
- Switch Mode: Manual button / remote software switching, switching time ≤2s
- Supported OS: Windows 7/10/11, Linux (Ubuntu/CentOS)
- Security Features: Hard disk data encryption, operation log recording
- Physical Parameters: Dimension 150×80×25mm, weight 0.5kg, PCIe slot installation
6.2.3 KITOZER-IC-1000 (Confidential Grade)
- Hardware Architecture: Dual motherboard, dual hard disk & dual network card high-security isolation architecture
- Interfaces: 4×SATA hard disk ports, 4×RJ45 network ports, 4×USB ports, 2×HDMI ports
- Isolation Performance: 4000V isolation voltage, military-grade electrical isolation
- Switch Mode: Hardware button / software / centralized remote control, switching time ≤1s
- Supported OS: Windows, Linux, domestic operating systems (Kylin / Tongxin)
- Security Features: SM4 national cryptographic hard disk encryption, transmission encryption, illegal switching interception, operation log audit
- Physical Parameters: Dimension 200×100×30mm, weight 0.8kg, PCIe slot installation
6.3 KITOZER-GAP-1000/10G Physical Isolation Gateway Specifications
6.3.1 KITOZER-GAP-1000 (Enterprise Grade)

Field Deployment of Industrial Gateway
- System Architecture: Dual-host with electronic switch isolation component, fully physically disconnected links
- Hardware Interfaces: 4×10/100/1000Mbps RJ45 Ethernet ports, 2×Console management ports, 2×USB ports
- Isolation Performance: 3000Vrms isolation voltage, no direct network connection between internal and external networks
- Transmission Performance: 1000Mbps transmission rate, data exchange latency 5-10ms, supporting file/database/video transmission
- Supported Protocols: TCP/IP, FTP, HTTP, Modbus RTU/TCP, Profinet
- Security Features: SM3 national cryptographic data verification, malicious protocol filtering, intrusion detection, ≥5Gbps DDoS resistance
- Log Audit: 128GB log storage, log retention ≥180 days, supporting log query & export
- Power Supply: AC 100-240V, 50/60Hz, dual power redundancy, power consumption ≤150W
- Environmental Parameters: Operating temp -20℃~60℃, storage temp -30℃~75℃, relative humidity 5%-95% (non-condensing)
- Physical Parameters: 1U rackmount, dimension 440×280×44mm, weight 5kg, anti-static & anti-electromagnetic metal enclosure
6.3.2 KITOZER-GAP-10G (Confidential Grade)
- System Architecture: Dual-host with optical isolation component, fully physically disconnected links for high-security isolation
- Hardware Interfaces: 4×10Gbps single-mode optical ports, 4×10/100/1000Mbps RJ45 Ethernet ports, 2×Console management ports, 4×USB ports
- Isolation Performance: 4000Vrms isolation voltage, military-grade electrical isolation, zero direct network-layer communication
- Transmission Performance: 10Gbps transmission rate, data exchange latency 2-5ms, supporting high-speed transfer of large files, mass databases and HD videos
- Supported Protocols: Full protocol parsing & stripping, supporting TCP/IP, industrial protocols, database protocols and national cryptographic encryption protocols
- Security Features: SM1/SM2/SM3/SM4 national cryptographic algorithms, data desensitization, keyword filtering, ≥10Gbps DDoS resistance, malicious code filtering, intrusion prevention
- Log Audit: 1TB log storage, log retention ≥365 days, supporting centralized audit & compliance analysis
- Power Supply: AC 100-240V, 50/60Hz, hot redundant dual power, remote power management, power consumption ≤300W
- Environmental Parameters: Operating temp -25℃~70℃, storage temp -40℃~85℃, relative humidity 5%-95% (non-condensing)
- Physical Parameters: 2U rackmount, dimension 440×450×88mm, weight 10kg, military-grade anti-corrosion, anti-vibration & anti-electromagnetic metal enclosure
- Certifications: Cybersecurity Class 3, Confidential Information System Product Certification, National Cryptography Authority Certification
6.4 KITOZER-DD-10G One-way Data Diode Specifications
- Transmission Principle: One-way optical signal transmission (separated TX transmitting / RX receiving modules), zero feedback channel
- Hardware Interfaces: 2×10Gbps single-mode optical ports (separated TX/RX), 2×10/100/1000Mbps RJ45 Ethernet ports, 1×Console management port
- Isolation Performance: 4000Vrms isolation voltage, physical one-way isolation, data only transmitted from low-security to high-security domains
- Transmission Performance: 10Gbps transmission rate, bit error rate <10⁻¹², transmission latency 1-3ms, supporting high-speed one-way transfer of files, databases and instructions
- Supported Protocols: TCP/IP, database synchronization (MySQL/Oracle/SQL Server), file transfer, industrial protocols (Modbus/OPC UA)
- Security Features: SM3/SM4 national cryptographic algorithms, data integrity verification, keyword filtering, data desensitization, reverse penetration prevention
- Log Audit: 1TB log storage, log retention ≥365 days, full audit of one-way transmission activities
- Power Supply: AC 100-240V, 50/60Hz, dual power redundancy, power consumption ≤250W
- Environmental Parameters: Operating temp -25℃~70℃, storage temp -40℃~85℃, relative humidity 5%-95% (non-condensing)
- Physical Parameters: 2U rackmount, dimension 440×450×88mm, weight 9kg, military-grade metal enclosure
- Certifications: Confidential Information System Product Certification, National Cryptography Authority Certification, Cybersecurity Class 3 Certification

Stacked Rackmount KITOZER Devices
6.5 KITOZER-PG-500 Industrial Protocol Isolation Gateway Specifications
- Hardware Interfaces: 2×1000Mbps RJ45 Ethernet ports, 2×RS485 serial ports, 1×DC power port
- Isolation Performance: 3000Vrms isolation voltage, electrical isolation between industrial and office networks
- Transmission Performance: 500Mbps transmission rate, protocol conversion latency ≤5ms, supporting high-speed forwarding of industrial protocols
- Supported Protocols: Modbus RTU/TCP, Profinet, OPC UA, DNP3, supporting protocol parsing, stripping and reconstruction
- Security Features: Industrial protocol whitelist control, malicious protocol field filtering, instruction legitimacy verification, industrial control attack prevention
- Power Supply: DC 9-36V industrial wide voltage, power consumption ≤80W, redundant power supply supported
- Environmental Parameters: Operating temp -20℃~60℃, storage temp -30℃~75℃, relative humidity 5%-95% (non-condensing), anti-vibration & anti-electromagnetic interference
- Physical Parameters: Dimension 200×150×50mm, weight 1.5kg, metal enclosure, DIN rail / desktop installation
6.6 KITOZER-ENC-1000 National Cryptography Encryption Module Specifications
- Supported Encryption Algorithms: SM1/SM2/SM3/SM4 national cryptographic algorithms, compatible with AES/RSA international algorithms
- Hardware Interfaces: 1×PCIe 3.0 port, 2×USB 3.0 ports
- Encryption Performance: 10Gbps encryption & decryption speed, 256-bit key length
- Functional Features: Data transmission encryption, storage encryption, identity authentication, digital signature, key management
- Security Qualification: National Cryptography Authority certified, compliant with GM/T national cryptographic standards
- Physical Parameters: Dimension 100×80×20mm, weight 0.3kg, PCIe slot installation
6.7 KITOZER-MGT-1000 Centralized Management Platform Specifications
- Deployment Mode: Rackmount hardware / server software deployment (optional)
- Hardware Configuration: 4×1000Mbps RJ45 Ethernet ports, 2×USB ports, 1×HDMI port, 1TB storage, 8-core CPU, 16GB RAM
- Management Capacity: Supports centralized management of ≥100 KITOZER isolation devices, supporting device grouping, batch configuration & batch policy distribution
- Functional Features: Device status monitoring, configuration management, hierarchical permission control, centralized log storage & audit, unified alarm management (SMS/email/platform alert), remote device upgrade, report generation
- Supported OS: Domestic Linux operating system (Kylin / Tongxin), HTTPS encrypted WEB management interface
- Physical Parameters: 1U rackmount, dimension 440×280×44mm, weight 5kg
6.8 Power Module Specifications (PW-100/500/1000)
6.8.1 KITOZER-PW-100 (Entry Grade)
- Input: AC 100-240V, 50/60Hz
- Output: DC 5V/2A
- Protection Functions: Overvoltage, overcurrent, short-circuit protection
- Dimension: 80×50×25mm, weight 0.2kg
6.8.2 KITOZER-PW-500 (Enterprise Grade)
- Input: AC 100-240V, 50/60Hz
- Output: DC 12V/5A
- Protection Functions: Overvoltage, overcurrent, short-circuit, lightning & surge protection
- Redundancy: Automatic dual-power switching
- Dimension: 220×120×50mm, weight 1kg
6.8.3 KITOZER-PW-1000 (Confidential/Military Grade)
- Input: AC 85-264V military wide voltage, 50/60Hz
- Output: DC 12V/10A
- Protection Functions: Overvoltage, overcurrent, short-circuit, lightning, surge & reverse connection protection
- Redundancy: Hot backup dual power, millisecond-level switchover
- Operating Temperature: -40℃~85℃
- Dimension: 250×150×60mm, weight 1.5kg
7. Full Product Application Scope
7.1 Network Isolator (KITOZER-NI-100) Application Scope
- Electrical isolation between industrial network devices to eliminate ground loop interference
- Isolation between office and monitoring networks to prevent monitoring equipment from intruding office networks
- Medical device network isolation to protect patient information, compliant with IEC 60601-1 standards
- Laboratory test equipment network isolation to avoid electromagnetic interference distorting test data
- Anti-interference, lightning protection and electrostatic protection for small businesses & home networks
7.2 Terminal Isolation Card (KITOZER-IC-100/500/1000) Application Scope
- KITOZER-IC-100: Dual-network isolation for office terminals of small enterprises (internal office system + external internet access), dual-network switching for non-confidential ordinary terminals
- KITOZER-IC-500: Office terminals of non-confidential government departments, corporate confidential business terminals, bank branch terminals, preventing information leakage between internal and external networks
- KITOZER-IC-1000: High-security dual-network isolation for military confidential terminals, government confidential network terminals, power core system terminals and financial core business terminals, complying with classified protection standards for confidential information systems
7.3 Physical Isolation Gateway (KITOZER-GAP-1000/10G) Application Scope
KITOZER-GAP-1000 (Enterprise Grade)
- Isolation between corporate intranet and internet with controllable data exchange
- Isolation between industrial control and office networks to secure industrial control systems
- Isolation between campus network and educational administration intranet to prevent student network intrusion into educational systems
- Isolation between hospital external networks and HIS internal systems to protect patient medical data
KITOZER-GAP-10G (Confidential Grade)
- Bidirectional controllable data exchange between government confidential and non-confidential networks, compliant with Cybersecurity Class 3 and confidential certification
- Isolation between R&D and production networks of military enterprises for high-security data interaction
- Isolation between core banking transaction networks and external networks to secure transaction data
- Isolation between power dispatching and information networks, meeting secondary power safety protection requirements
7.4 One-way Data Diode (KITOZER-DD-10G) Application Scope
- One-way export of confidential data from confidential networks to non-confidential networks to block confidential information leakage
- One-way data collection from industrial control systems (e.g. Power Safety Zone II → Safety Zone I)
- One-way backhaul of meteorological & environmental monitoring data to prevent reverse attacks on internal systems
- One-way synchronization of military production data to secure production networks
- One-way synchronization of financial disaster recovery data to prevent reverse intrusion of production systems via disaster recovery platforms
7.5 Industrial Protocol Isolation Gateway (KITOZER-PG-500) Application Scope
- Power Industry: Isolation between substation industrial control and office networks, Modbus/DNP3 protocol protection
- Chemical Industry: Isolation between DCS control systems and corporate networks, secure OPC UA protocol interaction
- Intelligent Manufacturing: Isolation between industrial robot/PLC networks and MES systems, Profinet protocol filtering
- Rail Transit: Isolation between on-board industrial control and ground monitoring networks, secure transmission of industrial instructions
7.6 National Cryptography Encryption Module (KITOZER-ENC-1000) Application Scope
- Encrypted data transmission & storage for confidential information systems
- Government, financial and military scenarios requiring national cryptographic algorithms
- Enhanced data encryption for isolation devices to upgrade security levels
- Domestic substitution projects compliant with national cryptographic standards and domestic operating systems
7.7 Centralized Management Platform (KITOZER-MGT-1000) Application Scope
- Centralized control of isolation equipment across multiple branches of large enterprises
- Unified management of isolation equipment in multi-region government & military institutions
- Operation & maintenance of large-scale isolation equipment for operators and financial industries
- Centralized monitoring and policy distribution of isolation equipment across multiple factories of industrial groups
8. Full Product Advantages
8.1 General Core Advantages (All Product Series)
- Strong Customization Capacity: Customizable hardware interfaces, software functions, protocols and appearance to meet personalized industry demands, with one-on-one technical solution customization service
- OEM/ODM Processing Service: Supports brand OEM labeling, customized R&D and mass production to match partners’ brand systems
- High Confidentiality: Hardware-level isolation & encryption for all products with no backdoors, compliant with confidential security standards and supporting national cryptographic algorithms to prevent information leakage & unauthorized data theft
- In-Stock Supply: Mainstream models held in inventory for delivery within 72 hours, priority production for urgent orders to shorten delivery cycles
- Leading Full-Range Technical Parameters: Maximum isolation voltage up to 4000V, maximum transmission rate up to 10Gbps, bit error rate as low as <10⁻¹², operating temperature range covering -40℃~85℃ to adapt to extreme harsh environments
- Domestic Compatibility: All products compatible with domestic operating systems (Kylin / Tongxin) and domestic chips, supporting domestic substitution in IT innovation projects
- Easy Deployment & Maintenance: Multiple management accesses including WEB/CLI/serial port, user-friendly graphical interface, remote configuration & upgrade to lower operation & maintenance thresholds
8.2 Exclusive Advantages of Each Product Series
8.2.1 Network Isolator (KITOZER-NI-100)
- Plug-and-play: Zero configuration & zero driver installation, ready for use after cable connection without professional technical support
- Low Power & High Stability: Power consumption ≤5W, anti-static metal enclosure, long-term trouble-free operation
- High Cost Performance: Affordable price for small-scale isolation demands to reduce procurement costs
8.2.2 Terminal Isolation Card (KITOZER-IC Series)
- Secure Switching: Hardware-level switching free of software vulnerabilities, fast switching without impacting office efficiency
- Wide Compatibility: Compatible with Windows/Linux/domestic operating systems and mainstream motherboards & hard disks
- Compact Size: PCIe slot installation without occupying extra space, suitable for desktops & workstations
8.2.3 Physical Isolation Gateway (KITOZER-GAP Series)
- Highest Physical Isolation Security: Dual-host + isolation component architecture with fully physically disconnected internal & external networks, blocking all attack paths
- Multi-Protocol Support: Compatible with general and industrial protocols to adapt to diverse data exchange scenarios
- High Reliability Redundancy: Dual power & dual host redundancy to eliminate single points of failure and ensure 7×24-hour operation
- Complete Compliance Certifications: Cybersecurity Class 3, Confidential Information System and National Cryptography Authority certifications to meet industry compliance requirements
8.2.4 One-way Data Diode (KITOZER-DD-10G)
- Absolute One-way Transmission: Physically separated one-way optical signal transmission with zero feedback channels, completely blocking reverse attacks for top-tier confidential security
- High Speed & Low Latency: 10Gbps transmission rate with latency ≤3ms, supporting high-speed one-way import of large files and mass data
- Military-Grade Protection: Adapts to extreme temperatures and harsh environments, anti-vibration & anti-electromagnetic interference with ultra-high reliability
8.2.5 Industrial Protocol Isolation Gateway (KITOZER-PG-500)
- In-depth Industrial Protocol Adaptation: Specialized in parsing & protecting industrial protocols including Modbus/Profinet/OPC UA
- Low Latency & High Stability: Protocol conversion latency ≤5ms without compromising real-time performance of industrial control systems to guarantee continuous production
- Industrial-Grade Environmental Adaptation: Wide-voltage power supply (DC 9-36V), anti-vibration & anti-electromagnetic interference for harsh factory environments
8.2.6 National Cryptography Encryption Module (KITOZER-ENC-1000)
- National Cryptography Authority Certified: Compliant with GM/T national cryptographic standards for guaranteed encryption security
- High-Speed Encryption: 10Gbps encryption speed without sacrificing data transmission efficiency
- Multi-Algorithm Compatibility: Supports both national cryptographic and international algorithms to meet diverse encryption demands
8.2.7 Centralized Management Platform (KITOZER-MGT-1000)
- Efficient Centralized Operation & Maintenance: Single platform managing hundreds of devices with batch configuration & upgrade to drastically cut maintenance costs
- Full-Dimensional Monitoring: Real-time tracking of device status, operating parameters and alarms for timely fault detection & resolution
- Domestic Security: Developed based on domestic operating systems with HTTPS encrypted WEB interface to prevent unauthorized access to management permissions
9. Tender-Specification Parameters for All Products (Marked with *)
9.1 Network Isolator (KITOZER-NI-100) Tender Parameters
- *Interfaces: ≥2 10/100Mbps adaptive RJ45 Ethernet ports
- *Isolation Voltage: ≥2500Vrms
- *Transmission Rate: ≥100Mbps
- *Power Supply: DC 5V/1A, low power consumption ≤5W
- *Operating Temperature: -10℃~55℃
- *Installation Mode: Desktop, metal enclosure
9.2 Terminal Isolation Card (KITOZER-IC Series) Tender Parameters
9.2.1 KITOZER-IC-100
- *Architecture: Single motherboard with dual hard disk isolation architecture
- *Interfaces: ≥2 SATA ports, ≥2 RJ45 ports
- *Isolation Voltage: ≥2500V
- *Switch Mode: Manual button switching, switching time ≤3s
- *Supported OS: Windows 7/10/11
9.2.2 KITOZER-IC-500
- *Architecture: Dual motherboard with dual hard disk isolation architecture
- *Interfaces: ≥4 SATA ports, ≥2 RJ45 ports, ≥2 USB ports
- *Isolation Voltage: ≥3000V
- *Switch Mode: Manual / remote software switching, switching time ≤2s
- *Security Features: Hard disk data encryption, operation log recording supported
- *Supported OS: Windows, Linux
9.2.3 KITOZER-IC-1000
- *Architecture: Dual motherboard, dual hard disk & dual network card high-security isolation architecture
- *Interfaces: ≥4 SATA ports, ≥4 RJ45 ports, ≥4 USB ports
- *Isolation Voltage: ≥4000V
- *Switch Mode: Hardware button / software / centralized remote control, switching time ≤1s
- *Security Features: SM4 national cryptographic hard disk encryption, transmission encryption, illegal switching interception
- *Supported OS: Windows, Linux, domestic operating systems
9.3 Physical Isolation Gateway (KITOZER-GAP Series) Tender Parameters
9.3.1 KITOZER-GAP-1000
- *Architecture: Dual-host with electronic switch isolation component, fully physically disconnected links
- *Interfaces: ≥4 10/100/1000Mbps RJ45 ports, ≥2 Console ports
- *Isolation Voltage: ≥3000Vrms
- *Transmission Rate: ≥1000Mbps, data exchange latency ≤10ms
- *Supported Protocols: TCP/IP, FTP, HTTP, Modbus
- *Security Features: SM3 national cryptographic data verification, ≥5Gbps DDoS resistance
- *Log Storage: ≥128GB, log retention ≥180 days
- *Power Supply: AC 100-240V, dual power redundancy
- *Form Factor: 1U rackmount
9.3.2 KITOZER-GAP-10G
- *Architecture: Dual-host with optical isolation component, fully physically disconnected links
- *Interfaces: ≥4 10Gbps single-mode optical ports, ≥4 10/100/1000Mbps RJ45 ports
- *Isolation Voltage: ≥4000Vrms
- *Transmission Rate: ≥10Gbps, data exchange latency ≤5ms
- *Supported Protocols: Full protocol parsing & stripping, national cryptographic encryption protocols supported
- *Security Features: SM1/SM2/SM3/SM4 national cryptographic algorithms, ≥10Gbps DDoS resistance, malicious code filtering
- *Log Storage: ≥1TB, log retention ≥365 days
- *Power Supply: AC 100-240V, hot redundant dual power, remote power management
- *Form Factor: 2U rackmount
- *Certifications: Cybersecurity Class 3, Confidential Information System Product Certification, National Cryptography Authority Certification
9.4 One-way Data Diode (KITOZER-DD-10G) Tender Parameters
- *Transmission Principle: One-way optical signal transmission (separated TX/RX), zero feedback channel
- *Interfaces: ≥2 10Gbps single-mode optical ports, ≥2 10/100/1000Mbps RJ45 ports
- *Isolation Voltage: ≥4000Vrms
- *Transmission Rate: ≥10Gbps, bit error rate <10⁻¹², transmission latency ≤3ms
- *Supported Protocols: TCP/IP, database synchronization, file transfer, industrial protocols
- *Security Features: SM3/SM4 national cryptographic algorithms, data desensitization, keyword filtering
- *Log Storage: ≥1TB, log retention ≥365 days
- *Power Supply: AC 100-240V, dual power redundancy
- *Form Factor: 2U rackmount
- *Certifications: Confidential Information System Product Certification, National Cryptography Authority Certification, Cybersecurity Class 3 Certification
9.5 Industrial Protocol Isolation Gateway (KITOZER-PG-500) Tender Parameters
- *Interfaces: ≥2 1000Mbps RJ45 ports, ≥2 RS485 serial ports
- *Isolation Voltage: ≥3000Vrms
- *Transmission Rate: ≥500Mbps, protocol conversion latency ≤5ms
- *Supported Protocols: Modbus RTU/TCP, Profinet, OPC UA
- *Security Features: Industrial protocol whitelist control, malicious protocol field filtering
- *Power Supply: DC 9-36V industrial wide voltage
- *Operating Temperature: -20℃~60℃
- *Installation Mode: DIN rail / desktop installation
9.6 National Cryptography Encryption Module (KITOZER-ENC-1000) Tender Parameters
- *Supported Encryption Algorithms: SM1/SM2/SM3/SM4 national cryptographic algorithms
- *Interfaces: ≥1 PCIe 3.0 port, ≥2 USB 3.0 ports
- *Encryption Speed: ≥10Gbps
- *Key Length: 256-bit
- *Certification: National Cryptography Authority certified, compliant with GM/T national cryptographic standards
9.7 Centralized Management Platform (KITOZER-MGT-1000) Tender Parameters
- *Hardware Configuration: ≥4 1000Mbps RJ45 ports, ≥1TB storage, ≥8-core CPU, ≥16GB RAM
- *Management Capacity: Supports centralized control of ≥100 isolation devices
- *Functional Features: Device status monitoring, batch configuration, centralized log audit, unified alarm management, remote upgrade
- *Supported OS: Domestic Linux operating system
- *Management Interface: HTTPS encrypted WEB interface
9.8 Power Module Tender Parameters
9.8.1 KITOZER-PW-100
- *Input: AC 100-240V
- *Output: DC 5V/2A
- *Protection Functions: Overvoltage, overcurrent, short-circuit protection
9.8.2 KITOZER-PW-500
- *Input: AC 100-240V
- *Output: DC 12V/5A
- *Protection Functions: Overvoltage, overcurrent, short-circuit, lightning & surge protection
- *Redundancy: Automatic dual-power switching
9.8.3 KITOZER-PW-1000
- *Input: AC 85-264V military wide voltage
- *Output: DC 12V/10A
- *Protection Functions: Overvoltage, overcurrent, short-circuit, lightning, surge & reverse connection protection
- *Redundancy: Hot backup dual power, millisecond-level switchover
- *Operating Temperature: -40℃~85℃
10. Full Product Solutions
10.1 Small Enterprise / Office Network Isolation Solution
10.1.1 Demand Scenario
Office terminals of small enterprises require simultaneous connection to internal networks (office systems, file servers) and external networks (Internet, email). The solution blocks external network viruses and hacker intrusions into internal networks, with limited budget and simple deployment requirements.
10.1.2 Solution Configuration (Entry Grade)
- Terminal Isolation Card: KITOZER-IC-100 (1 piece per office terminal)
- Network Isolator: KITOZER-NI-100 (1 unit between internal switch and external router)
- Power Module: KITOZER-PW-100 (1 unit)
10.1.3 Solution Advantages
- Low Cost: Entry-grade device combination with high cost performance matching small enterprise budgets
- Easy Deployment: Plug-and-play with zero complex configuration, operable by ordinary staff
- Dual-Layer Isolation: Terminal dual-network isolation + network electrical isolation to block external attack paths
- Low Maintenance: Stable & reliable equipment with low failure rate to reduce operation & maintenance workload
10.2 Industrial Control Network Isolation Solution
10.2.1 Demand Scenario
Industries including power, chemical and intelligent manufacturing require isolation between industrial control networks (PLC, DCS, SCADA) and office/Internet networks to prevent industrial control viruses and malicious attacks, guarantee continuous production, and support secure interaction of industrial protocols.
10.2.2 Solution Configuration (Enterprise Grade)
- Industrial Protocol Isolation Gateway: KITOZER-PG-500 (1 unit between industrial control and office networks)
- Standard Physical Isolation Gateway: KITOZER-GAP-1000 (1 unit between office network and Internet)
- Enterprise Terminal Isolation Card: KITOZER-IC-500 (1 piece for industrial control operation terminals)
- Redundant Power Module: KITOZER-PW-500 (2 units)
- Security Audit Module: KITOZER-AUD-500 (1 unit)
10.2.3 Solution Advantages
- In-depth Industrial Protocol Adaptation: Full support for Modbus/Profinet/OPC UA with protocol filtering & whitelist control to secure industrial control instructions
- Low Latency & High Stability: Protocol conversion latency ≤5ms without compromising real-time performance of industrial control systems; dual power redundancy eliminates single points of failure
- Multi-Layer Defense: Three-tier isolation (industrial control network-office network-Internet) to build in-depth defense and block attack paths
- Traceable Audit: Full log recording compliant with industrial security standards for fault investigation and liability tracing
10.3 Government / Military Confidential Network Isolation Solution
10.3.1 Demand Scenario
Confidential government departments and military enterprises require isolation between confidential networks (secret & top-secret data) and non-confidential/Internet networks, supporting one-way export of confidential data and controllable import of non-confidential data, compliant with classified protection standards for confidential information systems and Cybersecurity Class 3, with ultra-high security and confidentiality to prevent information leakage.
10.3.2 Solution Configuration (Confidential Grade)
- One-way Data Diode: KITOZER-DD-10G (1 unit for one-way data transmission from confidential to non-confidential networks)
- High-End Physical Isolation Gateway: KITOZER-GAP-10G (1 unit for controllable bidirectional data exchange between non-confidential and confidential networks)
- Military-Grade Terminal Isolation Card: KITOZER-IC-1000 (1 piece for confidential office terminals)
- National Cryptography Encryption Module: KITOZER-ENC-1000 (1 unit for each gateway & data diode)
- Military-Grade Redundant Power Supply: KITOZER-PW-1000 (4 units)
- Centralized Management Platform: KITOZER-MGT-1000 (1 set)
10.3.3 Solution Advantages
- Top-Tier Security: Triple high-security protection combining absolute one-way transmission of data diodes, physical disconnection of isolation gateways and national cryptographic encryption, fully compliant with confidential certification standards
- Controllable Data Interaction: One-way export of confidential data with zero feedback channels, controllable bidirectional exchange of non-confidential data with protocol filtering & audit to balance security and business efficiency
- Centralized Control: Unified management of multiple devices with centralized policy distribution to reduce operation & maintenance risks
- Extreme Environment Adaptation: Military-grade equipment adapting to extreme temperatures, vibration and electromagnetic interference to guarantee stable operation of confidential systems
10.4 Financial Industry Network Isolation Solution
10.4.1 Demand Scenario
Banks, securities firms and insurance companies require isolation between core transaction networks and external networks (UnionPay, third-party payment platforms) and office networks to secure transaction data, prevent data tampering & leakage, support high-concurrency high-speed data transmission, and comply with financial industry Cybersecurity Class 3 standards.
10.4.2 Solution Configuration (Confidential Grade)
- High-End Physical Isolation Gateway: KITOZER-GAP-10G (1 unit between core transaction network and external network)
- One-way Data Diode: KITOZER-DD-10G (1 unit for one-way synchronization of core transaction data to disaster recovery networks)
- National Cryptography Encryption Module: KITOZER-ENC-1000 (2 units)
- Military-Grade Redundant Power Supply: KITOZER-PW-1000 (4 units)
- Centralized Management Platform: KITOZER-MGT-1000 (1 set)
10.4.3 Solution Advantages
- High-Speed High-Concurrency Processing: 10Gbps transmission rate supporting high-concurrency financial transaction processing with low latency without impacting transaction efficiency
- Transaction Security: National cryptographic encryption + data desensitization + keyword filtering to prevent leakage & tampering of transaction data
- Disaster Recovery Security: One-way data diodes realize disaster recovery data synchronization with zero risk of reverse intrusion into core transaction networks
- Compliance Certification: Cybersecurity Class 3 and national cryptographic certifications meeting financial regulatory requirements
10.5 Medical Industry Network Isolation Solution
10.5.1 Demand Scenario
Hospital HIS systems storing massive patient privacy data require isolation from external and monitoring networks to prevent leakage & tampering of medical data, while supporting external online appointment services and access to monitoring data to balance security and public convenience services.
10.5.2 Solution Configuration (Enterprise Grade)
- Standard Physical Isolation Gateway: KITOZER-GAP-1000 (1 unit between HIS internal network and external network)
- Network Isolator: KITOZER-NI-100 (1 unit between HIS internal network and monitoring network)
- Enterprise Terminal Isolation Card: KITOZER-IC-500 (1 piece for doctor office terminals)
- Redundant Power Module: KITOZER-PW-500 (2 units)
10.5.3 Solution Advantages
- Privacy Protection: Physical isolation + data encryption to block leakage of patient medical data
- Business Compatibility: Supports external online appointments and real-time monitoring data access without disrupting hospital public services
- Stable & Reliable Operation: Dual power redundancy to guarantee 7×24-hour operation of HIS systems and avoid interruption of medical services
- Compliance Adaptation: Compliant with medical industry data security compliance standards
11. Full Product Application Cases
11.1 Confidential Network Isolation Project of Provincial Government
11.1.1 Project Background
Confidential departments of a provincial government required construction of an isolation system between confidential and non-confidential networks to realize one-way export of confidential documents and controllable import of non-confidential documents, complying with classified protection standards for confidential information systems and Cybersecurity Class 3 to secure government confidential information.
11.1.2 Project Configuration
- One-way Data Diode: KITOZER-DD-10G ×2 units
- High-End Physical Isolation Gateway: KITOZER-GAP-10G ×2 units
- Military-Grade Terminal Isolation Card: KITOZER-IC-1000 ×50 pieces
- National Cryptography Encryption Module: KITOZER-ENC-1000 ×4 units
- Centralized Management Platform: KITOZER-MGT-1000 ×1 set
11.1.3 Project Outcomes
- Compliance Achievement: Passed classified protection certification for confidential information systems and Cybersecurity Class 3 assessment to meet government confidential security standards
- Data Security: One-way export of confidential files with zero feedback channels completely eliminates risks of confidential information leakage
- Efficient Office Work: Controllable bidirectional exchange of non-confidential files supports data interconnection of government office systems without compromising work efficiency
- Stable Operation: The system has run stably for 2 years post-launch without security failures or data leakage incidents
11.2 Industrial Control Network Isolation Project of Large Power Group
11.2.1 Project Background
A large power group with 10 subordinate substations required isolation between industrial control networks (SCADA systems, PLC equipment) and office/Internet networks to prevent industrial control virus intrusions, guarantee stable power production, and support secure interaction of industrial protocols.
11.2.2 Project Configuration
- Industrial Protocol Isolation Gateway: KITOZER-PG-500 ×10 units (1 unit per substation)
- Standard Physical Isolation Gateway: KITOZER-GAP-1000 ×2 units (isolation between group headquarters office network and Internet)
- Enterprise Terminal Isolation Card: KITOZER-IC-500 ×30 pieces (operation & maintenance terminals)
- Security Audit Module: KITOZER-AUD-500 ×10 units
11.2.3 Project Outcomes
- Industrial Control Security: Multiple industrial control virus attacks were successfully blocked without industrial control system intrusions, guaranteeing continuous power production
- Protocol Adaptation: Perfect compatibility with power industrial protocols including Modbus and DNP3, protocol conversion latency ≤5ms without impacting real-time monitoring of industrial control systems
- Efficient Operation & Maintenance: Dual-network isolation for operation & maintenance terminals enables secure access to both industrial control and office networks to boost maintenance efficiency
- Compliance Acceptance: Passed secondary power safety protection inspection to meet power industrial control safety specifications
11.3 Core Transaction Network Isolation Project of National Commercial Bank
11.3.1 Project Background
A national commercial bank required isolation between core transaction networks and UnionPay external networks/Internet to secure bank card transaction data, prevent data tampering, leakage and hacker attacks, support high-concurrency transaction processing, and comply with financial industry Cybersecurity Class 3 standards.
11.3.2 Project Configuration
- High-End Physical Isolation Gateway: KITOZER-GAP-10G ×3 units
- One-way Data Diode: KITOZER-DD-10G ×2 units
- National Cryptography Encryption Module: KITOZER-ENC-1000 ×6 units
- Centralized Management Platform: KITOZER-MGT-1000 ×1 set
11.3.3 Project Outcomes
- Transaction Security: No incidents of transaction data leakage or tampering post-launch; multiple DDoS attacks were successfully resisted to guarantee stable operation of transaction systems
- High-Concurrency Processing: 10Gbps transmission rate supports processing of 100,000 transactions per second with zero latency or stuttering
- Reliable Disaster Recovery: One-way data diodes realize disaster recovery data synchronization with zero risk of disaster recovery system reverse intrusion into core transaction networks
- Compliance Approval: Smoothly passed financial industry Cybersecurity Class 3 assessment to meet banking and insurance regulatory commission supervision requirements
11.4 Office Network Isolation Project of Small E-Commerce Enterprise
11.4.1 Project Background
A small e-commerce enterprise with 20 office terminals required simultaneous connection to internal networks (order systems, financial systems) and external networks (Internet, e-commerce platforms) to block external virus intrusions into internal networks, with limited budget and requirements for simple deployment & low maintenance workload.
11.4.2 Project Configuration
- Terminal Isolation Card: KITOZER-IC-100 ×20 pieces
- Network Isolator: KITOZER-NI-100 ×2 units
- Power Module: KITOZER-PW-100 ×2 units
11.4.3 Project Outcomes
- Internal Network Security: Effectively blocks external viruses and Trojans from intruding internal networks; no security failures occurred in order and financial systems
- Convenient Office Work: One-click switching between internal and external networks for terminals without impacting employee efficiency, no additional staff training required
- Controllable Costs: Entry-grade device combination delivers low procurement costs matching small enterprise budgets
- Low Maintenance Burden: Stable & reliable equipment with nearly zero operation & maintenance workload to save labor costs
11.5 HIS System Isolation Project of Grade A Tertiary Hospital
11.5.1 Project Background
The HIS system of a Grade A tertiary hospital stores massive patient privacy data and required isolation from external and monitoring networks to prevent patient information leakage, while supporting external online appointment services and access to monitoring data to balance security and public convenience services.
11.5.2 Project Configuration
- Standard Physical Isolation Gateway: KITOZER-GAP-1000 ×2 units
- Network Isolator: KITOZER-NI-100 ×3 units
- Enterprise Terminal Isolation Card: KITOZER-IC-500 ×40 pieces
11.5.3 Project Outcomes
- Privacy Protection: No incidents of patient medical data leakage to protect patient privacy security
- Convenient Public Services: Supports external online appointment registration and real-time monitoring data viewing without disrupting hospital public services
- Stable Operation: Year-round stable operation of HIS systems without service interruptions to guarantee normal medical diagnosis order
- Compliance Achievement: Passed medical industry data security compliance inspection to meet medical privacy protection requirements
12. Full Product Troubleshooting & Maintenance Specifications
12.1 Common Faults & Troubleshooting Methods
12.1.1 Network Isolator (KITOZER-NI-100)
- Fault Phenomenon: Network disconnection, indicator lights off
- Troubleshooting Steps: Check normal power connection & stable DC 5V supply; replace Ethernet cables to rule out cable faults; inspect loose or damaged device interfaces
- Resolution: Reconnect power supply, replace qualified Ethernet cables, fasten loose interfaces; return equipment to factory for repair if interfaces are damaged
- Fault Phenomenon: Severe packet loss & unstable transmission
- Troubleshooting Steps: Check whether isolation voltage meets standards and ground loop interference exists; verify operating temperature does not exceed 55℃; confirm cable length ≤100 meters
- Resolution: Optimize wiring layout to eliminate ground loop currents; improve heat dissipation to lower device temperature; replace short-distance high-quality Ethernet cables
12.1.2 Terminal Isolation Card (KITOZER-IC Series)
- Fault Phenomenon: Unable to switch networks, switch button unresponsive
- Troubleshooting Steps: Check secure installation of isolation card and PCIe slot contact integrity; inspect loose hard disk/network card interfaces; verify correct installation of switching drivers (software-switch models)
- Resolution: Reinsert isolation card and fasten interfaces; reinstall switching drivers and restart PC; return to factory for repair if hardware damage occurs
- Fault Phenomenon: No network connection after switching
- Troubleshooting Steps: Check normal cable connection of corresponding network; verify normal network card drivers; inspect damaged network interfaces of isolation card
- Resolution: Replace Ethernet cables, update network card drivers; return to factory for repair if interfaces are damaged
12.1.3 Physical Isolation Gateway (KITOZER-GAP Series)
- Fault Phenomenon: Device fails to power on, power indicator off
- Troubleshooting Steps: Check normal AC power input; inspect damaged dual power modules; verify loose power interfaces
- Resolution: Replace power sockets and check supply voltage; swap spare power modules; fasten power interfaces; return to factory for repair if hardware damage occurs
- Fault Phenomenon: Failed data exchange between internal and external networks
- Troubleshooting Steps: Check normal cable connection of internal/external gateway interfaces; verify correct network configuration (IP, gateway, subnet mask); confirm properly configured isolation policies and no blocked required protocols
- Resolution: Reconnect Ethernet cables and verify network configuration; inspect & adjust isolation policies to release required protocols; restart gateway services; restore factory settings and reconfigure if system failure occurs
- Fault Phenomenon: Excessively high data exchange latency & slow transmission speed
- Troubleshooting Steps: Check sufficient network bandwidth; verify overheating of gateway; confirm massive malicious data filtering; check full log storage
- Resolution: Expand network bandwidth; improve heat dissipation and clean dust from ventilation openings; optimize filtering policies to release legitimate data; clear expired logs to free storage space
12.1.4 One-way Data Diode (KITOZER-DD-10G)
- Fault Phenomenon: Failed one-way data transmission
- Troubleshooting Steps: Check secure optical port connection and fully inserted optical modules; verify correct TX/RX connection order (transmit / receive ends not reversed); inspect damaged optical modules
- Resolution: Reinsert optical modules and connect TX/RX correctly; replace qualified optical modules; inspect broken optical fibers and replace fiber cables
- Fault Phenomenon: High bit error rate during data transmission
- Troubleshooting Steps: Check qualified optical fiber quality; confirm transmission distance does not exceed single-mode fiber limit (≤10km); inspect dust contamination on optical ports
- Resolution: Replace high-quality single-mode optical fibers; shorten transmission distance; clean dust from optical ports and protect with dust caps after use
12.1.5 Industrial Protocol Isolation Gateway (KITOZER-PG-500)
- Fault Phenomenon: Failed forwarding of industrial control protocols
- Troubleshooting Steps: Check secure serial/RJ45 interface connection; verify correct industrial protocol configuration (Modbus address, baud rate); confirm required protocols are released in whitelist policies
- Resolution: Fasten interfaces and verify protocol configuration; adjust whitelist policies to release required industrial control protocols; restart gateway services
- Fault Phenomenon: Communication interruption of industrial control equipment
- Troubleshooting Steps: Check stable gateway power supply (DC 9-36V); verify overheating operating temperature; confirm legitimate industrial control instructions are not filtered due to industrial control protocol attack interception
- Resolution: Stabilize power supply and improve heat dissipation; optimize filtering policies to release legitimate industrial control instructions; troubleshoot self-faults of industrial control equipment
12.1.6 Centralized Management Platform (KITOZER-MGT-1000)
- Fault Phenomenon: Unable to manage devices, all devices displayed offline
- Troubleshooting Steps: Check network connectivity between platform and devices; verify correct configured management IP of devices; confirm sufficient platform administrator permissions
- Resolution: Troubleshoot network connectivity and verify management IP; log in with administrator account to obtain full management permissions; restart platform services
- Fault Phenomenon: Failed log storage or query
- Troubleshooting Steps: Check full platform storage space; verify normal operation of log storage services
- Resolution: Clear expired logs and expand storage capacity; restart log storage services; repair corrupted system files
12.2 Daily Maintenance & Inspection Specifications
12.2.1 Environmental Maintenance
- Temperature Control: Strictly maintain device operating temperature within product parameter ranges; equip computer rooms/equipment cabinets with air conditioners and cooling fans to avoid overheating or ultra-low temperature environments
- Humidity Control: Maintain relative humidity between 5%-95% (non-condensing); deploy dehumidifiers in humid environments to prevent short-circuit and corrosion of equipment
- Dust Cleaning: Clean dust on device surfaces, ventilation openings and interfaces monthly with dry soft cloth; dust accumulation impairs heat dissipation and causes poor interface contact
- Anti-Vibration & Anti-Corrosion: Securely install equipment to avoid severe vibration; keep away from acid/alkali corrosive gas to prevent corrosion of equipment enclosures and internal components
12.2.2 Hardware Maintenance
- Power Supply Inspection: Inspect power modules, power cables and interfaces quarterly to ensure tight connections without aging or damage; periodically test redundant power switchover to guarantee normal backup power function
- Interface Inspection: Inspect Ethernet cables, optical fibers, serial cables and interfaces monthly to ensure tight connection without looseness or damage; cover optical ports with dust caps after use to prevent dust contamination
- Equipment Fastening: Inspect mounting screws of rackmount devices and fixing components of desktop equipment semi-annually to guarantee secure installation without falling risks
12.2.3 Software Maintenance
- Configuration Backup: Back up device configuration files immediately after setup and store securely; update backup files monthly to avoid configuration loss
- Firmware Upgrade: Track official firmware releases and upgrade device firmware quarterly to fix vulnerabilities and optimize performance; back up configurations prior to upgrade to prevent configuration loss from failed upgrades
- Log Management: Clear expired logs monthly to free storage space; archive critical logs for fault troubleshooting and compliance audit
- Permission Management: Update device management passwords quarterly with high complexity standards; clean redundant administrator accounts and implement hierarchical permission control to prevent permission leakage
12.2.4 Regular Inspection Schedule
- Daily Inspection: Check indicator light status, equipment operation and alarm information to confirm normal operation without abnormal alerts
- Weekly Inspection: Inspect device temperature, humidity and power supply status; monitor data transmission rate & latency to verify normal data exchange
- Monthly Inspection: Clean equipment dust, inspect interface connection status, back up device configuration files and check logs for abnormalities
- Quarterly Inspection: Upgrade device firmware, test redundant power switchover function, verify equipment fault alarm triggers and optimize isolation/filter policies
- Semi-Annual Inspection: Full hardware inspection (power supply, interfaces, mainboard); test all device performance indicators and verify configuration policies to ensure compliance with operating standards