Table of Contents
Toggle1. System Overview
KITOZER Secure Isolation GAP (Full Name: Secure Isolation and Information Exchange System) is a self-developed high-security network protection device by Guangzhou Lai’an Intelligent System Development Co., Ltd. It addresses the core demand of “physical isolation + controllable data exchange” between networks of different security levels (e.g., internal/external networks, classified/unclassified networks, industrial control/office networks). It completely blocks direct TCP/IP connections, eliminates risks of APT attacks, virus infiltration and data leakage, while supporting compliant secure data transmission of files, databases, video streams, industrial protocols and more. Widely deployed in government, public security & procuratorate & court, energy, healthcare, finance, large enterprises and other sectors, it complies with Classified Protection of Cybersecurity Version 2.0, power security specifications, classified information system grading protection and other compliance standards.

KITOZER GAP Hardware
2. System Composition
KITOZER GAP adopts a mature 2+1 physical isolation architecture (dual hosts + isolation switching module) with fully independent hardware links and modular software design. Its core components are as follows:
- External Network Processing Unit (External Host) An independent hardware host connected to low-security domains (Internet, office networks). It receives data, strips protocols, performs preliminary filtering and security detection, and runs a dedicated secure operating system without generic network protocol stacks to prevent infiltration from external network attacks.
- Internal Network Processing Unit (Internal Host) An independent hardware host connected to high-security domains (classified networks, industrial control networks, core business networks). It receives data, reconstructs protocols, conducts in-depth filtering and security auditing, and adopts localized hardware and national cryptographic algorithms to secure internal network data.
- Isolation Switching Module (Data Transmission Unit) The core hardware isolation component built on dedicated FPGA chips and solid-state storage media. It only connects to either the internal or external network at any given time to realize “protocol-free data transmission”. It physically cuts off network connections to block all TCP/IP-based attack paths, and supports unidirectional/bidirectional data transmission control.
- Management & Control Unit Equipped with local management ports, centralized management platform and security audit modules for device configuration, policy distribution, status monitoring, log auditing and alarm management. It supports SNMP, SSH and Web management with visual operation & maintenance interfaces.
- Security Protection Module Integrates virus scanning, malicious code detection, sensitive content filtering, access control, data encryption, identity authentication, watermark traceability and other functions to build an end-to-end security protection system.

GAP Mechanical Drawing
3. System Classification
3.1 Classification by Data Flow Direction
- Unidirectional GAP: Supports one-way data transmission only (external → internal, industrial control → office network) with no reverse channel to eliminate reverse attack risks. Suitable for power industrial control, classified data import, sensitive data export and other scenarios.
- Bidirectional GAP: Enables controllable bidirectional data exchange between internal and external networks with strict transmission policy management. Ideal for cross-departmental government data sharing, internal-external enterprise file exchange, medical data interconnection and other scenarios.
- Forward Isolation Device: Power industrial control dedicated unidirectional GAP, only allowing data flow from industrial control zones (Zone I/II) to office zones (Zone III/IV). It parses IEC 104, Modbus and other industrial control protocols to meet power security zoning specifications.
- Reverse Isolation Device: Power industrial control dedicated unidirectional GAP, only allowing data flow from office networks to industrial control networks with no TCP session feedback to prevent reverse attacks on industrial control systems.
3.2 Classification by Functional Modules

Production Workshop
- File Exchange GAP: Specialized in secure file transmission, supporting batch file transfer, format filtering, virus scanning, resume transmission and file deduplication. Applicable to office file exchange, data backup & migration scenarios.
- Database Synchronization GAP: Supports cross-network synchronization of mainstream databases including Oracle, MySQL, SQL Server and PostgreSQL, with data desensitization, field filtering, incremental synchronization and real-time synchronization capabilities. Suitable for cross-network sharing of enterprise core databases and data disaster recovery.
- Video Transmission GAP: Parses RTSP, RTMP, H.264/H.265 and other video protocols to realize secure unidirectional/bidirectional transmission of high-definition video. Deployed in public security video surveillance, radio & television video distribution, campus video isolation and other scenarios.
- Industrial Protocol GAP: Deeply parses IEC 60870-5, Modbus, DNP3, S7 and other industrial control protocols, supporting industrial instruction filtering, unidirectional data transmission and protocol whitelist management for power, rail transit, intelligent manufacturing and other industrial control scenarios.
3.3 Classification by Performance Tier
- Entry-level (Basic Configuration): Throughput 100Mbps–1Gbps, concurrent connections ≤1000. For small enterprises, branch offices and small office network isolation.
- Enterprise-level (Mid-range Configuration): Throughput 1Gbps–10Gbps, concurrent connections 1000–5000. For medium-sized enterprises, government departments, medical institutions and energy branches.
- Flagship-level (High-end Configuration): Throughput 10Gbps–40Gbps, concurrent connections ≥5000. Supports dual-machine hot standby and cluster deployment with full localized stack adaptation. For large conglomerates, provincial government agencies, military units, IDC computer rooms and core industrial control systems requiring high security and high concurrency.
4. System Working Principle
The core logic of KITOZER GAP is “Protocol Stripping → Data Transmission → Protocol Reconstruction”, featuring full physical isolation and time division multiplexing without persistent network connections. The workflow is shown below:
Low-security Domain (External Network)
↓
[External Processing Unit] → Protocol stripping (remove TCP/IP headers) → Data filtering & virus scanning
↓
[Isolation Switching Module] → Physically disconnect external network → Write data to cache → Disconnect external network again → Connect internal network → Read cache (protocol-free transmission)
↓
[Internal Processing Unit] → Protocol reconstruction (restore application data) → In-depth filtering & security auditing
↓
High-security Domain (Internal Network)

On-site Installation
5. Full System Configuration List (KITOZER Brand, Entry / Mid / High Tiers)
5.1 Entry-level Configuration (KITOZER-GAP-L100, Small Enterprises / Branches, 100Mbps–1Gbps)
è¡¨æ ¼
| No. | Product Name | Model | Technical Specs | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Secure Isolation GAP Host | KITOZER-GAP-L100 | 2+1 physical isolation architecture; Throughput:100Mbps; 4×GE electrical ports; Dedicated secure OS; Unidirectional/bidirectional transmission; Concurrent connections ≤1000; 1U rack-mount; Single AC220V power supply | 1 | Unit | KITOZER | Basic isolation, file exchange |
| 2 | Management Console Software | KITOZER-MGR-L | Configuration management, policy distribution, log audit, status monitoring; Web/local management supported | 1 | Set | KITOZER | Standard, free license |
| 3 | Virus Scanning Module | KITOZER-AV-L | Detect & remove common viruses, trojans and malicious code; Automatic virus database update | 1 | Set | KITOZER | Optional on demand |
| 4 | Rack Mounting Kit | KITOZER-RACK-1U | 1U rack rails, fixing screws, grounding cable | 1 | Set | KITOZER | Standard with host |
| 5 | Power Cord | KITOZER-PWR-L | 1.5m AC220V national standard power cord | 1 | Piece | KITOZER | Standard |
5.2 Enterprise-level Configuration (KITOZER-GAP-M10G, Medium Enterprises / Government Departments, 1Gbps–10Gbps)
è¡¨æ ¼
| No. | Product Name | Model | Technical Specs | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Secure Isolation GAP Host | KITOZER-GAP-M10G | 2+1 physical isolation; Throughput:10Gbps; 8×GE electrical ports + 2×10G SFP+ optical ports; Localized secure OS; Unidirectional/bidirectional transmission; Concurrent connections 5000; 2U rack-mount; Dual redundant AC220V power supplies; Supports database/file/video modules | 1 | Unit | KITOZER | Full-function isolation, multi-protocol support |
| 2 | Management Console Software | KITOZER-MGR-M | Centralized management, visual O&M, alarm linkage, log export, hierarchical permission control | 1 | Set | KITOZER | Standard, free license |
| 3 | Virus Scanning Module | KITOZER-AV-M | Advanced virus detection, malicious code analysis, file hash verification, real-time virus database update | 1 | Set | KITOZER | Standard |
| 4 | Database Synchronization Module | KITOZER-DB-M | Supports Oracle/MySQL/SQL Server/PostgreSQL; Incremental/real-time synchronization, data desensitization | 1 | Set | KITOZER | Optional on demand |
| 5 | File Exchange Module | KITOZER-FILE-M | Batch file transfer, resume transmission, deduplication, format filtering, permission control | 1 | Set | KITOZER | Standard |
| 6 | Rack Mounting Kit | KITOZER-RACK-2U | 2U rack rails, fixing screws, grounding cable, cable management rack | 1 | Set | KITOZER | Standard |
| 7 | Redundant Power Cords | KITOZER-PWR-M | 2m AC220V national standard power cords, dual power backup | 2 | Piece | KITOZER | Standard |
| 8 | Optical Transceiver (Optional) | KITOZER-SFP+-10G | 10G multi-mode/single-mode optical module compatible with 10G SFP+ ports | 2 | Piece | KITOZER | Optional on demand |
5.3 Flagship Configuration (KITOZER-GAP-H40G, Large Conglomerates / Military / Provincial Agencies, 10Gbps–40Gbps)
è¡¨æ ¼
| No. | Product Name | Model | Technical Specs | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Secure Isolation GAP Host | KITOZER-GAP-H40G | 2+1 physical isolation; Throughput:40Gbps; 16×GE electrical ports + 8×10G SFP+ optical ports + 4×40G QSFP+ optical ports; Localized Kirin secure OS; Unidirectional/bidirectional transmission; Concurrent connections ≥10000; 4U rack-mount; Dual redundant AC220V/DC48V power supplies; Supports cluster & dual-machine hot standby; National cryptographic algorithm compatible | 1 | Unit | KITOZER | High security & high concurrency, full-scenario adaptation |
| 2 | Centralized Management Platform Software | KITOZER-MGR-H | Multi-device cluster management, unified policy distribution, global log audit, big data analysis, alarm linkage | 1 | Set | KITOZER | Standard, free license |
| 3 | Advanced Security Protection Module | KITOZER-SEC-H | Virus scanning, malicious code detection, sensitive content filtering, data encryption, identity authentication, watermark traceability, DLP data leakage prevention | 1 | Set | KITOZER | Standard |
| 4 | Database Synchronization Module | KITOZER-DB-H | Full database compatibility; Real-time/incremental/full synchronization, data desensitization, field filtering, cross-database synchronization | 1 | Set | KITOZER | Standard |
| 5 | Industrial Protocol Module | KITOZER-IND-H | Deep parsing of IEC 60870-5/Modbus/DNP3/S7; Instruction filtering, whitelist management | 1 | Set | KITOZER | Optional for industrial control scenarios |
| 6 | Video Transmission Module | KITOZER-VID-H | Supports RTSP/RTMP/H.264/H.265; Secure unidirectional/bidirectional HD video transmission, video encryption | 1 | Set | KITOZER | Optional for video surveillance scenarios |
| 7 | Dual-machine Hot Standby Kit | KITOZER-HA-H | Hot standby software, synchronization cable, heartbeat detection module, automatic failover | 1 | Set | KITOZER | Optional for high-availability scenarios |
| 8 | Rack Mounting Kit | KITOZER-RACK-4U | 4U rack rails, fixing screws, grounding cable, cable organizer, cabinet tray | 1 | Set | KITOZER | Standard |
| 9 | Redundant Power Cords | KITOZER-PWR-H | 2.5m AC220V/DC48V power cords, dual power backup | 2 | Piece | KITOZER | Standard |
| 10 | High-speed Optical Transceiver | KITOZER-QSFP+-40G | 40G single/multi-mode optical module compatible with 40G QSFP+ ports | 4 | Piece | KITOZER | Optional on demand |
6. Full Product Technical Specifications

GAP Structure Diagram
6.1 KITOZER-GAP-L100 (Entry-level GAP Host)
- Physical Architecture: 2+1 (external host + internal host + isolation switching module), fully independent hardware links
- Throughput: 100Mbps (unidirectional/bidirectional)
- Interfaces: 4×10/100/1000Mbps adaptive RJ45 electrical ports
- Operating System: Dedicated embedded secure OS without generic network protocol stacks
- Transmission Mode: Unidirectional & bidirectional controllable data transmission
- Concurrent Connections: ≤1000
- Data Latency: ≤1ms
- Supported Protocols: File transfer (FTP/SMB), basic TCP/UDP application protocols
- Security Functions: Basic access control, virus scanning, log audit
- Power Supply: Single power, AC 100-240V, 50/60Hz, power consumption ≤50W
- Dimension: 1U (44.5mm × 480mm × 260mm), rack-mountable
- Operating Environment: 0℃–45℃, humidity 10%–90% (non-condensing)
6.2 KITOZER-GAP-M10G (Enterprise-level GAP Host)
- Physical Architecture: 2+1, internal/external hosts with independent CPU, memory and storage; isolation module built on dedicated FPGA chips
- Throughput: 10Gbps (unidirectional/bidirectional)
- Interfaces: 8×GE electrical ports + 2×10G SFP+ expandable optical ports
- Operating System: Localized secure OS compatible with domestic IT innovation ecosystems
- Transmission Mode: Unidirectional/bidirectional with refined controllable transmission policies
- Concurrent Connections: 5000
- Data Latency: ≤0.5ms
- Supported Protocols: Files, databases, video, HTTP/HTTPS, email and other mainstream protocols
- Security Functions: Advanced virus scanning, sensitive content filtering, data desensitization, identity authentication, SSL encryption
- Power Supply: Dual redundant power, AC 100-240V, 50/60Hz, power consumption ≤150W
- Dimension: 2U (89mm × 480mm × 350mm), rack-mountable
- Operating Environment: -10℃–50℃, humidity 10%–95% (non-condensing)
- Reliability: Supports dual-machine hot standby and automatic failover
6.3 KITOZER-GAP-H40G (Flagship GAP Host)

IDC Cabinet Deployment
- Physical Architecture: 2+1; internal/external hosts equipped with localized CPUs; isolation switching module with high-speed dedicated FPGA chips
- Throughput: 40Gbps (unidirectional/bidirectional)
- Interfaces: 16×GE electrical ports + 8×10G SFP+ optical ports + 4×40G QSFP+ expandable optical ports
- Operating System: Localized Kirin secure OS with full domestic IT innovation stack compatibility
- Transmission Mode: Unidirectional/bidirectional, multi-link load balancing & cluster deployment supported
- Concurrent Connections: ≥10000
- Data Latency: ≤0.3ms
- Supported Protocols: All file types, databases, industrial protocols, video protocols and custom protocols
- Security Functions: National cryptographic algorithm encryption, DLP data leakage prevention, watermark traceability, advanced threat detection, log big data analysis
- Power Supply: Dual redundant power, AC 100-240V/DC -48V, 50/60Hz, power consumption ≤300W
- Dimension: 4U (178mm × 480mm × 550mm), rack-mountable
- Operating Environment: -20℃–60℃, humidity 5%–95% (non-condensing)
- Reliability: Supports cluster, dual-machine hot standby, hardware redundancy and automatic fault switching
6.4 Supporting Module Technical Specifications

Central Control Platform
- Virus Scanning Module: Automatic virus database update, virus detection rate ≥99.9%, detects and removes common viruses, trojans and ransomware
- Database Synchronization Module: Compatible with Oracle 11g+/MySQL 5.7+/SQL Server 2012+/PostgreSQL 9.6+, synchronization latency ≤1s, supports incremental/real-time/full synchronization
- Industrial Protocol Module: Supports IEC 60870-5-104, Modbus RTU/TCP, DNP3, S7; protocol parsing accuracy ≥99.9%
- Video Transmission Module: Supports RTSP/RTMP/H.264/H.265, max 4K resolution, transmission latency ≤200ms
7. Full Product Application Scope
KITOZER GAP covers nine core industries including government, public security & procuratorate & court, energy, healthcare, finance, large enterprises, military, rail transit and intelligent manufacturing, adapting to over 100 segmented scenarios:
- Government & Public Security & Procuratorate & Court: Isolation between classified and unclassified networks, government internal network and Internet, cross-departmental data sharing, isolation between public security internal network and video private network, secure exchange of classified court & procuratorate data; complies with Classified Protection of Cybersecurity Version 2.0 and grading protection standards.
- Energy Industry (Power / Petroleum / Chemical): Isolation between power production control zones (Zone I/II) and management information zones (Zone III/IV), separation of petrochemical production networks and office networks, one-way transmission of oil & gas pipeline monitoring data, secure upward reporting of power dispatching data; complies with Regulations on Security Protection of Power Monitoring Systems.

On-site Cabinet Deployment
- Healthcare Industry: Isolation between hospital HIS/LIS/PACS systems and the Internet, secure cross-hospital medical data sharing, protection of patient privacy data, separation of medical equipment monitoring networks and office networks; meets healthcare data compliance requirements.
- Finance Industry: Isolation between bank core business networks and the Internet, separation of securities trading networks and office networks, cross-network transmission of financial disaster recovery data, protection of sensitive customer information; complies with financial industry cybersecurity grading standards.
- Large Enterprises & Conglomerates: Isolation between headquarters internal network and branch external networks, separation of production and office networks, isolation of R&D classified networks and test networks, cross-regional data synchronization of enterprise data centers, secure exchange of supply chain data.
- Military & Scientific Research Institutes: Isolation between classified research networks and unclassified networks, separation of military production networks and office networks, one-way export of research data, secure transmission of classified documents; meets military confidentiality requirements.
- Rail Transit & Transportation Hubs: Isolation between metro/high-speed rail industrial control systems and office networks, separation of traffic surveillance video private networks and the Internet, secure transmission of ticketing system data, one-way upward reporting of traffic dispatching data.
- Intelligent Manufacturing & Industrial Internet: Isolation between industrial control networks (PLC/SCADA) and industrial Internet, one-way upload of production equipment data, secure access of industrial APPs, prevention of intelligent manufacturing data leakage.
- Education, Radio & Television & IDC: Isolation between university campus networks and classified research networks, separation of radio & television video production networks and broadcast networks, isolation of different security domains in IDC computer rooms, secure cross-tenant data exchange in cloud data centers.
8. Full Product Advantages
8.1 Core Functional Features
- True Physical Isolation for Ultimate Security: Adopts 2+1 architecture with no persistent connection between internal and external networks at any time. Raw data is transmitted after protocol stripping, completely blocking TCP/IP attack paths and eliminating infiltration risks from APT, viruses and trojans. Higher security level than logical isolation devices such as firewalls and IPS.
- Controllable Data Exchange – Isolation Without Business Interruption: Supports unidirectional/bidirectional data transmission with refined policy control (file type, size, transmission time, IP/port filtering). Compatible with files, databases, video and industrial protocols to balance security and operational efficiency.
- End-to-end Multi-layer Security Protection: Integrates virus scanning, malicious code detection, sensitive content filtering, data encryption, identity authentication, watermark traceability, DLP data leakage prevention and other functions to protect data from entry, transmission to output, preventing data leakage and malicious attacks.
- Full Localized Stack Compatibility for Domestic IT Innovation Compliance: Flagship models adopt localized CPUs and Kirin OS, compatible with national cryptographic algorithms, supporting deployment in domestic IT innovation environments to meet transformation requirements of government, military and state-owned enterprises.
- High Performance & Reliability for Stable Operation: Throughput ranges from 100Mbps (entry) to 40Gbps (flagship) to match diverse bandwidth demands. Dual redundant power, dual-machine hot standby and cluster deployment enable 7×24-hour uninterrupted operation with low failure rates for core business scenarios.
8.2 Customization & OEM/ODM Capabilities

Outdoor Cabinet Project Case
- In-depth Custom Development: Supports hardware interface customization (additional optical/electrical/industrial interfaces), software function customization (custom protocol parsing, exclusive security policies, industry-specific modules) and appearance customization (chassis size, color, LOGO) to meet personalized demands of various industries and scenarios.
- OEM/ODM Contract Manufacturing: Supports brand OEM labeling and customized ODM R&D, providing one-stop services including complete technical solutions, production manufacturing and testing & acceptance. Short bulk delivery cycles with controlled quality, suitable for channel vendors, system integrators and industrial clients with customized procurement demands.
- Industry-exclusive Customization: Develops dedicated customized modules for power, healthcare, finance, military and other sectors (e.g., power forward/reverse isolation devices, medical data desensitization modules, financial encryption modules) to deeply adapt to industry specifications and business workflows.
8.3 Confidentiality & Spot Inventory Advantages
- Military-grade Confidentiality Capability: Complies with Class II/III military confidentiality standards, supporting one-way transmission of classified data, encrypted transmission of classified documents and full audit of operational behaviors to prevent leakage of classified data for military, scientific research and government classified scenarios.
- Ample Spot Inventory: Full KITOZER GAP series (entry/mid/high tiers) maintain sufficient stock. Standard models ship within 3–7 days upon order, with 24-hour expedited delivery for urgent orders to enable rapid deployment without long lead times.
- Transparent Full-series Technical Specifications: All product technical parameters are fully disclosed and verifiable by third-party testing institutions without ambiguous descriptions, meeting requirements of government procurement, project bidding and engineering tendering.
9. Full Product Tender Control Specifications (Marked with *)
9.1 Universal Tender Specifications (Applicable to All Series)
-
- Product Type: Secure Isolation and Information Exchange System (GAP) adopting 2+1 physical isolation architecture
-
- Core Principle: Protocol Stripping – Data Transmission – Protocol Reconstruction, no persistent network connection between internal and external networks at any time
-
- Security Level: Compliant with Classified Protection of Cybersecurity Version 2.0 Level 3, classified information system grading protection and power security specifications
-
- Operating System: Dedicated secure OS / localized secure OS without generic network protocol stacks
-
- Transmission Mode: Supports unidirectional and bidirectional controllable data transmission with refined transmission policy management
-
- Security Functions: Integrated virus scanning, malicious code detection, sensitive content filtering and log audit functions
-
- Management Methods: Supports Web management, local management and centralized management platform with hierarchical permission control
-
- Power Supply: Supports AC 100-240V, 50/60Hz; flagship models support dual redundant power supplies
-
- Installation Method: Standard rack-mount (1U/2U/4U) compatible with standard cabinets
9.2 Entry-level Model (KITOZER-GAP-L100) Tender Specifications
-
- Throughput: ≥100Mbps (unidirectional/bidirectional)
-
- Interfaces: ≥4×10/100/1000Mbps adaptive electrical ports
-
- Concurrent Connections: ≥500
-
- Data Latency: ≤1ms
-
- Dimension: 1U rack-mount compatible with standard 19-inch cabinets
9.3 Enterprise-level Model (KITOZER-GAP-M10G) Tender Specifications
-
- Throughput: ≥10Gbps (unidirectional/bidirectional)
-
- Interfaces: ≥8×GE electrical ports + 2×10G SFP+ optical ports
-
- Concurrent Connections: ≥5000
-
- Data Latency: ≤0.5ms
-
- Reliability: Supports dual-machine hot standby and automatic failover
-
- Localization Compatibility: Compatible with localized secure OS and domestic IT innovation ecosystems
9.4 Flagship Model (KITOZER-GAP-H40G) Tender Specifications
-
- Throughput: ≥40Gbps (unidirectional/bidirectional)
-
- Interfaces: ≥16×GE electrical ports + 8×10G SFP+ optical ports + 4×40G QSFP+ optical ports
-
- Concurrent Connections: ≥10000
-
- Data Latency: ≤0.3ms
-
- Reliability: Supports cluster, dual-machine hot standby, hardware redundancy and automatic fault switching
-
- Localization Compatibility: Equipped with localized CPU + Kirin OS, compatible with national cryptographic algorithms, full domestic IT innovation stack adaptation
-
- Security Functions: Supports national cryptographic algorithm encryption, DLP data leakage prevention, watermark traceability and advanced threat detection
10. Full Product Solutions
10.1 Government Classified Network Isolation Solution
- Pain Points: Physical isolation is required between classified and unclassified networks while enabling compliant data exchange to prevent classified data leakage, complying with grading protection and Classified Protection of Cybersecurity Version 2.0 standards.
- Deployment Scheme: Deploy KITOZER flagship bidirectional GAP in series between classified and unclassified networks, configure unidirectional data transmission policies (classified data only allowed to flow out, not in), integrate identity authentication, watermark traceability and operation audit functions with full localized stack adaptation and unified management via centralized management platform.
- Solution Value: Realizes physical isolation of classified networks to eliminate data leakage risks; supports compliant bidirectional data exchange to guarantee operational efficiency; meets domestic IT innovation transformation and compliance requirements for government classified scenarios.
10.2 Power Industrial Control System Isolation Solution
- Pain Points: Physical isolation between power production control zones (Zone I/II) and management information zones (Zone III/IV) is required to prevent infiltration of industrial control systems from office network attacks and ensure stable power grid operation.
- Deployment Scheme: Deploy KITOZER enterprise-level forward isolation device + reverse isolation device (industrial control dedicated GAP) in series. The forward device allows data flow from industrial control zones to office zones, while the reverse device has no reverse channel. It deeply parses IEC 104, Modbus and other industrial control protocols with protocol whitelist configuration and industrial protocol in-depth filtering.
- Solution Value: Complies with power security zoning specifications to physically isolate industrial control and office networks; deeply filters industrial control protocols to block malicious instruction attacks; ensures secure real-time upward reporting of power grid dispatching data.
10.3 Enterprise Production & Office Network Isolation Solution
- Pain Points: Enterprise production networks (PLC/SCADA/ERP) must be protected from infiltration by office network viruses and trojans, while supporting synchronization of production data to office networks for operational collaboration.
- Deployment Scheme: Small and medium enterprises deploy KITOZER entry-level bidirectional GAP; large and medium enterprises deploy enterprise-level bidirectional GAP in series between production and office networks. Configure file & database synchronization policies with integrated virus scanning and data desensitization, supporting dual-machine hot standby for high availability.
- Solution Value: Physically isolates production and office networks to eliminate virus infiltration risks; enables secure synchronization of production data to support business collaboration with cost-effective options for enterprises of all sizes.
10.4 Healthcare Secure Data Exchange Solution
- Pain Points: Hospital HIS/LIS/PACS systems require isolation from the Internet to prevent leakage of patient privacy data, while enabling secure cross-hospital sharing of medical data to meet healthcare compliance standards.
- Deployment Scheme: Deploy KITOZER enterprise-level bidirectional GAP in series between hospital internal networks and the Internet/cross-hospital networks. Configure medical data desensitization policies (mask patient names, mobile numbers, ID numbers), integrate sensitive content filtering and data encryption to support secure transmission of medical files and imaging data.
- Solution Value: Protects patient privacy data from leakage; enables cross-hospital sharing of medical data to improve medical efficiency; complies with healthcare industry data compliance standards.
11. Full Product Application Cases
11.1 Provincial Government Classified Network Isolation Project
- Project Background: A provincial government needed physical isolation between classified office networks and unclassified government networks with support for compliant cross-departmental data exchange, complying with grading protection and domestic IT innovation transformation requirements.
- Deployed Products: 2 sets of KITOZER-GAP-H40G flagship GAP (dual-machine hot standby) + centralized management platform
- Implementation Results: Achieved physical isolation between classified and unclassified networks to eliminate classified data leakage risks; supported secure exchange of cross-departmental files and databases with data transmission speed up to 20Gbps; full localized stack adaptation, passed Classified Protection of Cybersecurity Version 2.0 Level 3 and grading protection assessment, stable operation for 3 years without faults.
11.2 Provincial State Grid Power Dispatching Isolation Project
- Project Background: A provincial State Grid dispatching center required physical isolation between production control zones (Zone I/II) and management information zones (Zone III/IV) to ensure secure operation of power grid dispatching systems.
- Deployed Products: 1 set of KITOZER-GAP-M10G enterprise-level forward isolation device + 1 set reverse isolation device
- Implementation Results: Strictly followed power security zoning specifications to physically isolate industrial control and office networks; deeply parsed IEC 104 industrial control protocols to filter malicious instructions and block reverse attacks; realized secure real-time upward reporting of power grid dispatching data, stable operation for 5 years without security incidents, passed power industry security assessment.
11.3 Large Manufacturing Enterprise Production Network Isolation Project
- Project Background: An automobile manufacturing enterprise required physical isolation between workshop industrial control networks (PLC/SCADA) and headquarters office networks to prevent infiltration by office network viruses, while supporting synchronization of production data to headquarters.
- Deployed Products: 1 set of KITOZER-GAP-M10G enterprise-level GAP + database synchronization module
- Implementation Results: Physically isolated production and office networks to eliminate virus & trojan infiltration risks; real-time synchronization of production data to headquarters databases with synchronization latency ≤1s; dual-machine hot standby support ensures 24/7 uninterrupted operation of production systems, stable operation for 2 years without faults.
11.4 Grade A Tertiary Hospital Medical Data Isolation Project
- Project Background: A grade A tertiary hospital needed isolation between internal HIS/LIS/PACS systems and the Internet to protect patient privacy data, while enabling secure cross-hospital sharing of medical imaging data.
- Deployed Products: 1 set of KITOZER-GAP-M10G enterprise-level GAP + file exchange module + video transmission module
- Implementation Results: Physical isolation between internal networks and the Internet achieves zero leakage of patient privacy data; secure cross-hospital transmission of medical imaging data supporting 4K high-definition images with transmission latency ≤200ms; passed healthcare industry data compliance assessment, stable operation for 1 year without faults.
12. Product Faults & Maintenance Specifications
12.1 Common Faults & Troubleshooting Methods
- Fault Phenomenon: GAP fails to boot, power indicator off
- Root Causes: Loose power cord, faulty power adapter, damaged power module, abnormal mains power
- Solutions: Reconnect power cord, check mains supply; replace power cord/adapter; contact manufacturer for power module repair
- Fault Phenomenon: Port indicators off, unable to connect to network
- Root Causes: Damaged network cable, loose interface, faulty network port, incorrect network configuration
- Solutions: Replace and re-plug network cable; verify network configuration (IP, subnet mask, gateway); contact manufacturer for network port repair
- Fault Phenomenon: Data transmission interrupted, unable to transfer files
- Root Causes: Incorrect transmission policy, unsupported file format, interception by virus scanning, insufficient bandwidth, faulty functional module
- Solutions: Check and correct transmission policies; confirm file formats are whitelisted; review virus scanning logs to release compliant files; upgrade bandwidth or optimize transmission configuration; contact manufacturer for module repair
- Fault Phenomenon: Unable to log into management platform
- Root Causes: Incorrect management IP, network disconnection, wrong account password, faulty management module
- Solutions: Confirm correct management IP and network connectivity; reset account password; contact manufacturer for management module repair
- Fault Phenomenon: Dual-machine hot standby failover failed
- Root Causes: Damaged heartbeat cable, incorrect synchronization configuration, inconsistent firmware versions of two devices, faulty hot standby module
- Solutions: Replace heartbeat cable; check and correct synchronization configuration; upgrade both devices to identical firmware versions; contact manufacturer for hot standby module repair
12.2 Routine Maintenance Standards
- Environmental Maintenance: Maintain operating temperature ranges: 0℃–45℃ (entry-level), -10℃–50℃ (enterprise-level), -20℃–60℃ (flagship); humidity 10%–90% (non-condensing). Regularly clean cabinet dust to ensure equipment ventilation, avoid direct sunlight, humid and high-temperature environments.
- Hardware Maintenance: Periodically inspect tightness and damage of power cords, network cables and optical transceivers; monitor device indicator status and troubleshoot abnormalities promptly; check dual redundant power supplies and hard disk status for flagship models regularly.
- Software Maintenance: Regularly upgrade device OS, functional module firmware and virus databases (weekly automatic update recommended); back up device configuration files monthly to prevent configuration loss; review system and security logs regularly to analyze abnormal behaviors.
- Security Maintenance: Update security policies (file filtering, access control, sensitive content filtering) periodically; audit operation logs to identify unauthorized operations; conduct regular security vulnerability scans and patch vulnerabilities promptly.
- Maintenance Cycles:
- Daily Inspection (1x/day): Check device status, indicator lights and logs
- Monthly Maintenance (1x/month): Dust cleaning, hardware connection inspection, configuration backup, virus database upgrade
- Quarterly Maintenance (1x/quarter): Full hardware inspection, software firmware upgrade, security policy optimization
- Annual Maintenance (1x/year): On-site manufacturer inspection, equipment performance calibration, hidden fault troubleshooting
13. Factory Strength & After-sales Service
13.1 Factory Strength
- Enterprise Background: KITOZER is a brand owned by Guangzhou Lai’an Intelligent System Development Co., Ltd., a national high-tech enterprise specializing in R&D, production, sales and service of network security protection equipment and computer room infrastructure. With 15 years of experience in network security, it operates an independent R&D center, production base and testing laboratory covering 10,000 ㎡ with annual production capacity of 100,000 sets.
- R&D Strength: A team of over 50 professional R&D engineers with core technical staff holding more than 10 years of industry experience, focusing on R&D of GAP, firewalls, IPS, IDS, bastion hosts and other security devices. It holds over 50 invention patents and software copyrights with domestically leading technical capabilities.
- Production Strength: Fully automated production lines equipped with high-precision SMT mounters, wave soldering machines, aging test equipment and performance testing equipment. Manufacturing complies with ISO9001 quality management system and ISO14001 environmental management system certifications. Every unit undergoes 72-hour aging testing, performance testing and security testing before delivery with a product pass rate of 99.9%.
- Qualifications & Certifications: Products hold Ministry of Public Security network security product certification, Classified Protection of Cybersecurity Version 2.0 certification, classified information system product testing certification, power industry certification, healthcare industry certification, CE and FCC certifications, meeting requirements of government procurement, project bidding and industry compliance.
13.2 After-sales Service
- Service Commitment: Full KITOZER GAP series come with 3-year original manufacturer free warranty + lifetime technical support + 7×24-hour emergency response service. Free repair and component replacement for non-human damage within the warranty period; lifetime technical consultation, fault troubleshooting and firmware upgrade services.
- Service Network: 31 provincial/municipal offices and over 100 service outlets nationwide with professional technical engineers providing localized on-site services. 2-hour response time, 4-hour on-site arrival for provincial capitals, 8-hour on-site arrival for prefecture-level cities.
- Service Scope:
- Pre-sales Service: Free technical consultation, solution design, product selection and testing verification; customized exclusive solutions based on client demands
- Sales Service: Free equipment installation, commissioning, deployment and training to guide clients through online deployment, policy configuration and operation & maintenance
- After-sales Service: 7×24-hour technical hotline, online customer service, remote assistance, on-site repair, fault troubleshooting, firmware upgrade and component replacement services; regular client follow-ups to review equipment operation and provide O&M optimization suggestions
- Spare Parts Support: 5 national spare parts centers with sufficient stock of mainboards, power supplies, interface modules, hard disks and other components. Faulty devices within warranty enjoy priority spare parts replacement service to shorten downtime and ensure business continuity.
14. Conclusion
As the core network security protection product of Guangzhou Lai’an Intelligent System Development Co., Ltd., KITOZER Secure Isolation GAP (GAP) addresses the core pain point of “security isolation and data exchange” between networks of different security levels with five core strengths: true physical isolation, controllable data exchange, end-to-end security protection, full localized stack compatibility and high performance & reliability. Widely deployed in government, energy, healthcare, finance, large enterprises and other sectors, it complies with Classified Protection of Cybersecurity Version 2.0, grading protection, power security specifications and other compliance standards.
With 15 years of industry experience, strong R&D capabilities, advanced production processes, strict quality control systems and efficient after-sales service networks, the company delivers one-stop full-process services covering solution design, product selection, customized development, manufacturing, installation & commissioning and operation & maintenance. It helps clients build high-security, high-reliability and high-efficiency network security protection systems to safeguard core data and support stable business development.
Moving forward, KITOZER will continue to increase R&D investment, optimize product performance, expand functional coverage and enhance security protection capabilities. It will deepen domestic IT innovation adaptation and industry customized scenarios to deliver higher-quality, professional and reliable network security protection solutions for more industrial clients, supporting the safe and sound development of the digital economy.
15. SEO Keywords & Tag System
15.1 Core Keywords
GAP, Secure Isolation GAP, Network Security Isolation Device, Physical Isolation GAP
15.2 High-conversion Long-tail Keywords
KITOZER GAP, GAP Solution, Power GAP, Government GAP, Healthcare GAP, Industrial GAP, Bidirectional GAP, Unidirectional GAP, Localized GAP, GAP Configuration List
15.3 Industry Traffic Keywords
Network Security Protection Equipment, Secure Isolation and Information Exchange System, Industrial Control Network Isolation Device, Classified Network Isolation Device, Enterprise GAP Deployment Solution
15.4 Brand-exclusive Keywords
KITOZER Secure Isolation GAP, Guangzhou Lai’an GAP, KITOZER GAP, Lai’an Intelligent GAP
15.5 Drop-down & Related Search Keywords (Traffic Supplement Based on User Search Intent)
GAP Working Principle, Difference Between GAP and Firewall, GAP Application Scenarios, GAP Technical Specifications, Recommended GAP Brands
15.6 SEO Optimization Tag System
- Core Page Optimization Tag: GAP_Secure Isolation GAP_KITOZER GAP_GAP Solution
- Title Tag: KITOZER GAP Solution – Secure Isolation and Information Exchange System – Physical Isolation GAP Equipment
- Meta Keywords: GAP, Secure Isolation GAP, GAP, KITOZER GAP, GAP Solution, Physical Isolation GAP
- Meta Description: KITOZER Secure Isolation GAP (GAP) is a self-developed physical isolation protection device by Guangzhou Lai’an Intelligent. Adopting 2+1 architecture, it supports unidirectional/bidirectional data transmission, suitable for government, power, healthcare, enterprise and other scenarios, providing customized GAP solutions and 3-year warranty service.
- H1 Tag: KITOZER Secure Isolation GAP (GAP) Full Solution
- H2 Tags: System Overview, System Composition, System Classification, System Working Principle, System Configuration List, Product Technical Specifications, Application Scope, Product Advantages, Tender Control Specifications, Solutions, Application Cases, Faults & Maintenance Specifications, Factory Strength & After-sales Service, Conclusion
- Internal Link Anchor Text Tags
- Core Anchor Text: GAP, Secure Isolation GAP, KITOZER GAP
- Long-tail Anchor Text: GAP Solution, Power GAP, Localized GAP, Physical Isolation GAP
- Related Anchor Text: Network Security Protection Equipment, Secure Isolation and Information Exchange System, Industrial Control Network Isolation