KITOZER
KITOZER

KITOZER Industrial Sound Insulation Enclosure Noise Reduction Solution

Table of Contents

1. System Overview

The KITOZER industrial sound insulation enclosure is a professional noise control equipment designed based on the acoustic mass law and multi-layer composite structure. It delivers all-round noise reduction solutions for industrial high-noise sources. Adopting a five-step sound insulation chain technology of sound insulation – sound absorption – damping – vibration isolation – sealing, the system effectively suppresses equipment noise with a noise reduction range of 20–40 dB(A). It lowers operational noise of equipment from 90–120 dB(A) to below 75 dB(A), complying with GB12348-2008 Emission Standard for Industrial Enterprises Noise at Boundary and GBZ1-2010 Design Hygiene Standard for Industrial Enterprises.

Built on a modular design concept, the system supports rapid installation and flexible expansion, suitable for a full range of industrial scenarios including high-noise power equipment such as fans, air compressors, generators, water pumps, crushers and ball mills, as well as partial noise reduction for production lines. Integrated with ventilation & heat dissipation, maintenance access and monitoring functions, the enclosure ensures efficient noise control while guaranteeing normal equipment operation and convenient operation.

2. System Components

The KITOZER industrial sound insulation enclosure system consists of the following core assemblies to form a complete noise control system:

表格

Assembly CategoryCore ComponentsFunction Description
Main Structure SystemSound insulation enclosure body (steel plate + damping layer + sound absorption material + protective panel)Delivers basic sound insulation performance. The outer steel plate (1.5–3 mm) provides rigid support; the damping layer restrains resonance; sound absorption material (bulk density ≥48 kg/m³) absorbs reverberant noise inside the enclosure
Sealing SystemTriple magnetic sealing strips, elastic putty plugging, sound lock structureBlocks noise leakage paths, with door gap ≤1 mm; elastic plugging for wall-penetrating holes; sound lock structure reduces noise leakage when doors are opened
Ventilation & Heat Dissipation SystemLow-noise fans, noise elimination louvers, intelligent temperature control devicesSatisfies equipment heat dissipation requirements; fan noise ≤60 dB(A); noise elimination louvers provide noise reduction ≥15 dB; temperature control accuracy ±1℃
Vibration Isolation SystemSpring vibration isolators (natural frequency ≤5 Hz), rubber vibration isolation padsCuts solid-borne sound transmission paths; vibration transmission loss ≥20 dB, lowering structural resonance noise
Operation & Maintenance SystemSound insulation maintenance doors, double-layer observation windows (installed at 5° tilt), safety interlock devicesProvides maintenance access for equipment; observation windows deliver sound insulation ≥30 dB; safety interlocks prevent misoperation
Electrical Control SystemLighting system, alarm devices, remote monitoring interfacesEnsures safe operation inside the enclosure; supports docking with factory DCS systems for real-time status monitoring
Auxiliary SystemFire protection interfaces, gas detection devices, emergency ventilation outletsMeets safety requirements for special working conditions; adaptable to explosion-proof, anti-corrosion and harsh environments

3. System Classification

KITOZER industrial sound insulation enclosures are categorized by application scenarios and technical features as follows:

3.1 Classification by Enclosure Closure Degree

表格

TypeStructural FeaturesNoise Reduction PerformanceApplicable Scenarios
Fully Enclosed TypeCompletely wraps noise sources, equipped with powerful ventilation & heat dissipation systemsInsertion loss: 25–40 dB(A)Equipment with stable noise sources requiring infrequent operation (large fans, generators)
Partially Open TypeRetains observation/operation openings with partial wrapping of noise sourcesInsertion loss: 15–25 dB(A)Equipment requiring frequent intervention (production lines, machine tools)
Split Combined TypeMulti-module splicing, fully detachableInsertion loss: 20–35 dB(A)Large complex equipment requiring regular major overhauls (compressors, steam turbines)

3.2 Classification by Structural Form

表格

TypeDesign FeaturesAdvantagesApplicable Scenarios
Fixed StructureIntegrated welding/assembly with stable structureGood sealing and stable sound insulation effectEquipment permanently installed at fixed positions
Movable/Detachable TypeModular assembly connected by boltsEasy disassembly, transportation and reuseEquipment requiring regular maintenance, temporary noise reduction demands
Mobile TypeEquipped with casters/tracks for overall movementHigh flexibility, shared by multiple devicesSmall equipment, mobile operation scenarios

3.3 Classification by Noise Reduction Grade

表格

GradeNoise Reduction IndexStructural ConfigurationApplicable Scenarios
Standard Grade15–25 dB(A) noise reductionBasic composite structure, single-layer sealingGeneral industrial equipment with noise ≤90 dB(A)
Enhanced Grade25–35 dB(A) noise reductionReinforced composite structure, double-layer sealing + damping layerMedium-high noise equipment with noise 90–110 dB(A)
Professional Grade35–45 dB(A) noise reductionMulti-layer composite structure, multi-sealing + full vibration isolation systemHigh-noise equipment with noise ≥110 dB(A) (crushers, ball mills)

3.4 Classification by Special Functions

表格

TypeFunctional FeaturesApplicable Scenarios
Explosion-proof TypeAdopts explosion-proof materials and structures, compliant with GB3836 standardChemical, mining and other flammable & explosive environments
Anti-corrosion TypeOuter shell made of stainless steel/anti-corrosion coating, internal moisture-proof treatmentCoastal, chemical and other corrosive environments
High-temperature TypeHigh-temperature resistant materials, reinforced ventilation system, temperature resistance ≥200℃Boilers, melting furnaces and other high-temperature equipment
Low-temperature TypeThermal insulation layer design, temperature resistance ≤-40℃Cold storage, low-temperature test equipment

4. System Schematic Diagrams

4.1 Noise Reduction Principle Diagram

Noise Source → Inner Sound Absorption Material (sound absorption coefficient ≥0.9) → Damping Layer (resonance suppression) → Outer Steel Plate (sound insulation ≥30 dB) → Sealing System (sound bridge blocking) → Vibration Isolation System (solid-borne sound cut-off) → Ambient Environment (noise reduced by 20–40 dB)

4.2 Structural Principle Diagram

External Environment ← Outer Steel Plate (1.5–3 mm galvanized steel) ← Damping Coating (thickness ≥1 mm) ← Sound Absorption Layer (50–100 mm gradient-density sound absorption cotton) ← Perforated Protective Panel (perforation rate ≥20%) ← Internal Noise Source

4.3 Ventilation & Heat Dissipation System Principle Diagram

Hot air inside enclosure → Noise elimination louver (noise reduction ≥15 dB) → Low-noise fan (noise ≤60 dB(A)) → Exhaust silencer → Outdoor air

Cold outdoor air → Air intake silencer → Noise elimination louver → Inside enclosure

4.4 Vibration Isolation System Principle Diagram

Equipment vibration → Spring vibration isolator (natural frequency ≤5 Hz) → Vibration isolation pad → Ground/base

5. Full System Configuration List (KITOZER Brand, Divided into Low/Medium/High Grades)

5.1 Standard Grade Configuration List (Low Configuration)

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1Sound Insulation Enclosure ModuleKZ-GYZ-1000Outer 1.5 mm galvanized steel plate, middle 3 mm damping coating, inner 50 mm glass wool (bulk density 48 kg/m³), protective panel with 20% perforation rate4BlockKITOZERBasic sound insulation structure, 15–20 dB noise reduction
2Sound Insulation Maintenance DoorKZ-JXM-01Size 800×1800 mm, single-layer sealing, sound insulation ≥25 dB1SetKITOZERStandard configuration, no observation window
3Observation WindowKZ-GCC-01Size 400×600 mm, single-layer tempered glass, sound insulation ≥20 dB1PieceKITOZERBasic observation function
4Spring Vibration IsolatorKZ-JZQ-01Load capacity 500 kg, natural frequency ≤5 Hz, damping ratio ≥0.054PieceKITOZERBasic vibration isolation, vibration transmission loss ≥15 dB
5Noise Elimination LouverKZ-XSB-01Size 500×500 mm, noise reduction ≥12 dB, airflow resistance ≤100 Pa2PieceKITOZERBasic ventilation noise elimination
6Low-noise FanKZ-FJ-01Air volume 1000 m³/h, wind pressure 200 Pa, noise ≤65 dB(A)1UnitKITOZERBasic heat dissipation demand
7Sealing SystemKZ-MF-01Single-layer magnetic sealing strips, gap ≤1.5 mm1SetKITOZERBasic sealing to prevent noise leakage
8Lighting SystemKZ-ZM-012×20 W explosion-proof fluorescent lamp, illuminance ≥200 Lux1SetKITOZERBasic lighting demand
9Electrical Control BoxKZ-KZ-01Includes fan control, lighting control1UnitKITOZERBasic electrical control

5.2 Enhanced Grade Configuration List (Medium Configuration)

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1Sound Insulation Enclosure ModuleKZ-GYZ-2000Outer 2.0 mm galvanized steel plate, middle 5 mm damping coating, inner 80 mm gradient-density glass wool (bulk density 64 kg/m³), protective panel with 25% perforation rate4BlockKITOZERReinforced sound insulation structure, 25–30 dB noise reduction
2Sound Insulation Maintenance DoorKZ-JXM-02Size 800×1800 mm, single-door sound lock structure, double-layer sealing, sound insulation ≥30 dB1SetKITOZEREnhanced sealing, reduces noise leakage during door opening
3Observation WindowKZ-GCC-02Size 400×600 mm, double-layer tempered glass installed at 5° tilt, sound insulation ≥30 dB1PieceKITOZEREliminates standing wave resonance, improves sound insulation performance
4Spring Vibration IsolatorKZ-JZQ-02Load capacity 1000 kg, natural frequency ≤4 Hz, damping ratio ≥0.084PieceKITOZEREnhanced vibration isolation, vibration transmission loss ≥20 dB
5Noise Elimination LouverKZ-XSB-02Size 600×600 mm, noise reduction ≥15 dB, airflow resistance ≤80 Pa2PieceKITOZEREnhanced ventilation noise elimination effect
6Low-noise FanKZ-FJ-02Air volume 2000 m³/h, wind pressure 300 Pa, noise ≤60 dB(A)1UnitKITOZEREnhanced heat dissipation, low-noise design
7Intelligent Temperature Control DeviceKZ-WK-01Temperature range -20~80℃, control accuracy ±1℃, interlocks fan start/stop1UnitKITOZERIntelligent heat dissipation control, energy-saving and high-efficiency
8Sealing SystemKZ-MF-02Triple magnetic sealing strips, gap ≤1 mm, elastic putty plugging for wall-penetrating holes1SetKITOZEREnhanced sealing, eliminates sound bridge leakage
9Lighting SystemKZ-ZM-022×36 W explosion-proof fluorescent lamp, illuminance ≥300 Lux, emergency lighting function1SetKITOZEREnhanced lighting with emergency backup
10Electrical Control BoxKZ-KZ-02Fan control, lighting control, temperature interlock, fault alarm1UnitKITOZEREnhanced electrical control with early fault warning
11Safety Interlock DeviceKZ-LS-01Door body interlocks with fan, fan auto-shuts down when door opens1SetKITOZEREnsures operation safety
12Exhaust SilencerKZ-XSQ-01Noise reduction ≥15 dB, compatible with fan interfaces1PieceKITOZERFurther reduces exhaust noise

5.3 Professional Grade Configuration List (High Configuration)

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1Sound Insulation Enclosure ModuleKZ-GYZ-3000Outer 3.0 mm galvanized steel plate, middle 8 mm damping coating, inner 100 mm gradient-density rock wool (bulk density 80 kg/m³), protective panel with 30% perforation rate4BlockKITOZERProfessional sound insulation structure, 35–45 dB noise reduction
2Sound Insulation Maintenance DoorKZ-JXM-03Size 1000×2000 mm, double-door sound lock structure, triple-layer sealing, sound insulation ≥35 dB1SetKITOZERProfessional-grade sealing, noise leakage ≤5 dB when door opens
3Observation WindowKZ-GCC-03Size 500×800 mm, triple-layer tempered glass installed at 5° tilt, sound insulation ≥35 dB1PieceKITOZERProfessional observation window, eliminates standing wave resonance
4Air Flotation Vibration Isolation PlatformKZ-JZT-01Load capacity 2000 kg, natural frequency ≤2 Hz, vibration transmission loss ≥25 dB1UnitKITOZERProfessional vibration isolation for precision equipment
5Noise Elimination LouverKZ-XSB-03Size 800×800 mm, noise reduction ≥20 dB, airflow resistance ≤60 Pa2PieceKITOZERProfessional ventilation noise elimination
6Low-noise FanKZ-FJ-03Air volume 3000 m³/h, wind pressure 400 Pa, noise ≤55 dB(A)2UnitKITOZERDual-fan redundant design to guarantee heat dissipation
7Intelligent Temperature Control SystemKZ-WK-02Temperature range -40~120℃, control accuracy ±0.5℃, supports remote monitoring1SetKITOZERProfessional temperature control, compatible with high-temperature equipment
8Sealing SystemKZ-MF-03Quadruple magnetic sealing strips, gap ≤0.5 mm, liquid sealant plugging, sound bridge blocking design1SetKITOZERProfessional sealing, eliminates all noise leakage
9Lighting SystemKZ-ZM-034×36 W explosion-proof LED lamps, illuminance ≥500 Lux, emergency lighting + backup power supply1SetKITOZERProfessional lighting with emergency backup
10Electrical Control CabinetKZ-KZ-03PLC control, touch screen operation, fan frequency conversion control, temperature interlock, fault alarm, remote communication interface1UnitKITOZERProfessional electrical control, supports DCS docking
11Safety Interlock SystemKZ-LS-02Door body interlocks with fans and equipment power supply, auto-shutdown & power cut when door opens1SetKITOZERProfessional safety protection
12Air Intake & Exhaust SilencersKZ-XSQ-02Noise reduction ≥20 dB, compatible with dual fan interfaces2PieceKITOZERProfessional noise elimination to further cut airflow noise
13Gas Detection DeviceKZ-QT-01Detects CO, O₂ and flammable gas with adjustable alarm thresholds1SetKITOZERMeets safety demands of fully enclosed spaces
14Emergency Ventilation SystemKZ-TF-01Independent emergency fan, auto-start upon power failure1SetKITOZERProtects personnel safety
15Remote Monitoring ModuleKZ-JK-01Supports mobile APP/PC remote monitoring of temperature, noise and fan status1SetKITOZERProfessional operation & maintenance management

6. Full Product Technical Parameters

6.1 Sound Insulation Enclosure Module Technical Parameters

表格

ModelOuter Steel ThicknessDamping Layer ThicknessSound Absorption Layer ThicknessSound Absorption MaterialBulk DensityPerforation RateSound Insulation VolumeNoise Reduction EffectApplicable Noise Range
KZ-GYZ-10001.5 mm3 mm50 mmGlass Wool48 kg/m³20%≥25 dB15–20 dB≤90 dB(A)
KZ-GYZ-20002.0 mm5 mm80 mmGradient Glass Wool64 kg/m³25%≥30 dB25–30 dB90–110 dB(A)
KZ-GYZ-30003.0 mm8 mm100 mmGradient Rock Wool80 kg/m³30%≥35 dB35–45 dB≥110 dB(A)

6.2 Sound Insulation Maintenance Door Technical Parameters

表格

ModelSize (mm)Structural FormSealing LayersSound Insulation VolumeApplicable Scenarios
KZ-JXM-01800×1800Single Door1≥25 dBStandard Grade Configuration
KZ-JXM-02800×1800Single Door with Sound Lock2≥30 dBEnhanced Grade Configuration
KZ-JXM-031000×2000Double Door with Sound Lock3≥35 dBProfessional Grade Configuration

6.3 Observation Window Technical Parameters

表格

ModelSize (mm)Glass LayersInstallation AngleSound Insulation VolumeApplicable Scenarios
KZ-GCC-01400×600Single Layer0°≥20 dBStandard Grade Configuration
KZ-GCC-02400×600Double Layer5°≥30 dBEnhanced Grade, eliminates standing waves
KZ-GCC-03500×800Triple Layer5°≥35 dBProfessional Grade, high sound insulation demand

6.4 Vibration Isolation System Technical Parameters

表格

ModelTypeLoad Capacity (kg)Natural Frequency (Hz)Damping RatioVibration Transmission LossApplicable Scenarios
KZ-JZQ-01Spring Vibration Isolator500≤5≥0.05≥15 dBStandard Grade Configuration
KZ-JZQ-02Spring Vibration Isolator1000≤4≥0.08≥20 dBEnhanced Grade Configuration
KZ-JZT-01Air Flotation Vibration Isolation Platform2000≤2≥0.10≥25 dBProfessional Grade, precision equipment

6.5 Ventilation & Heat Dissipation System Technical Parameters

表格

ModelTypeSize (mm)Air Volume (m³/h)Wind Pressure (Pa)Noise Reduction (dB)Noise (dB(A))Applicable Scenarios
KZ-XSB-01Noise Elimination Louver500×500––≥12–Standard Grade Configuration
KZ-XSB-02Noise Elimination Louver600×600––≥15–Enhanced Grade Configuration
KZ-XSB-03Noise Elimination Louver800×800––≥20–Professional Grade Configuration
KZ-FJ-01Low-noise Fan–1000200–≤65Standard Grade Configuration
KZ-FJ-02Low-noise Fan–2000300–≤60Enhanced Grade Configuration
KZ-FJ-03Low-noise Fan–3000400–≤55Professional Grade Configuration
KZ-XSQ-01Silencer–––≥15–Enhanced Grade Configuration
KZ-XSQ-02Silencer–––≥20–Professional Grade Configuration

6.6 Electrical Control System Technical Parameters

表格

ModelControl FunctionsTemperature RangeControl AccuracyCommunication InterfaceApplicable Scenarios
KZ-KZ-01Fan + Lighting Control–––Standard Grade Configuration
KZ-KZ-02Fan + Lighting + Temperature Control + Alarm-20~80℃±1℃–Enhanced Grade Configuration
KZ-KZ-03PLC + Touch Screen + Frequency Conversion + Temperature Control + Alarm + Remote Communication-40~120℃±0.5℃RS485/EthernetProfessional Grade, DCS docking support

7. Full Product Application Scope

KITOZER industrial sound insulation enclosure systems are widely used across the following industries and equipment:

7.1 Power Equipment Sector

  • Fans: Centrifugal fans, axial fans, Roots blowers, air blowers, noise reduction 20–35 dB, compatible with all airflow and pressure grades
  • Compressors: Air compressors, screw compressors, piston compressors, noise reduction 25–35 dB, solves mechanical and airflow noise
  • Generators: Diesel, gasoline and gas generators, noise reduction 30–40 dB, suitable for indoor and outdoor installation
  • Pumps: Water pumps, oil pumps, mud pumps, noise reduction 20–30 dB, eliminates mechanical and fluid noise

7.2 Manufacturing & Processing Sector

  • Machine Tools: Punch presses, milling machines, grinders, lathes, noise reduction 20–30 dB, fits production line layout
  • Crushing Equipment: Crushers, ball mills, vibrating screens, noise reduction 30–45 dB, addresses high-noise crushing processes
  • Forging & Press Equipment: Forging presses, stamping machines, bending machines, noise reduction 25–35 dB, adapts to workshop environments
  • Welding Equipment: Welders, plasma cutting machines, noise reduction 15–25 dB, improves operating environments

7.3 Power & Energy Sector

  • Transformers: Power transformers, dry-type transformers, noise reduction 20–30 dB, meets factory boundary noise standards
  • Switchgear: High/low voltage switch cabinets, noise reduction 15–25 dB, improves power distribution room environments
  • Cooling Towers: Industrial cooling towers, central air conditioning cooling towers, noise reduction 20–30 dB, eliminates fan and water flow noise

7.4 Other Special Sectors

  • Chemical Equipment: Reaction kettles, agitators, valves & pumps; explosion-proof and anti-corrosion enclosures available, noise reduction 20–35 dB
  • Mining Equipment: Tunneling machines, coal miners, ventilation fans; mobile and explosion-proof enclosures available, noise reduction 25–40 dB
  • Medical Equipment: Medical centrifuges, hyperbaric oxygen chambers; clean enclosures available, noise reduction 15–25 dB
  • Scientific Research Equipment: High-noise lab equipment, test platforms; precision enclosures available, noise reduction 30–45 dB

8. Full Product Advantages

8.1 Functional Features of Full Product Series

  1. High-efficiency Noise Reduction Performance: Adopts five-step sound insulation chain technology of sound insulation – sound absorption – damping – vibration isolation – sealing, delivering 20–45 dB(A) noise reduction, exceeding industry standards.
  2. Multi-layer Composite Structure: Outer 1.5–3 mm galvanized steel for rigid support; middle damping layer suppresses low-frequency resonance; inner gradient-density sound absorption material with sound absorption coefficient ≥0.9 to cover full-frequency noise (low, medium and high).
  3. Professional Sealing Design: Multi-layer magnetic sealing strips and elastic putty plugging; minimum gap ≤0.5 mm to eliminate sound bridge leakage and guarantee sound insulation performance.
  4. Intelligent Ventilation & Heat Dissipation: Integrated low-noise fans (≤55 dB) and noise elimination louvers (noise reduction ≥20 dB); intelligent temperature control delivers precise temperature regulation to ensure safe equipment operation.
  5. Safe & Reliable Design: Equipped with safety interlocks, emergency ventilation systems and gas detection devices to protect operators, compliant with GB/T 19889 series standards.

8.2 Customization Service Capacity

  1. Full-size Customization: Custom sizes ranging from 0.5 m to 20 m based on equipment dimensions, shape and installation space, adapting to irregular equipment and complex workshop layouts.
  2. Special Working Condition Customization: Explosion-proof (GB3836 compliant), anti-corrosion, high-temperature (≥200℃ resistance), low-temperature (≤-40℃ resistance) and other special functional customization to meet diverse industrial demands.
  3. Modular Function Customization: Customizable ventilation volume, sound insulation volume, observation window quantity and maintenance door positions to fit equipment operation and maintenance needs.
  4. Color & Appearance Customization: Multiple coating color options to match factory corporate image and enhance workshop aesthetics.

8.3 OEM & Confidentiality Services

  1. OEM/ODM Processing: Supports customer brand customization, full-process OEM service from design to production for bulk procurement demands.
  2. Strict Confidentiality Agreements: Strict confidentiality of customer technical parameters, design drawings and production processes via formal non-disclosure agreements to protect intellectual property rights.
  3. Dedicated Project Teams: Dedicated engineering teams assigned to customized projects with one-on-one technical support to guarantee smooth project delivery.

8.4 Spot Supply & Delivery Capacity

  1. Standard Model Spot Inventory: Standard KZ-GYZ-1000/2000/3000 models available in stock with shipment within 72 hours for urgent noise reduction demands.
  2. Fast Custom Delivery: Modular production for customized projects; design, production and delivery completed within 15 days, far faster than industry average lead times.
  3. Nationwide Installation Service: Service outlets across major cities nationwide; on-site survey within 48 hours, installation and commissioning completed within 7 days.

8.5 Full Series Technical Parameter Advantages

表格

Technical ParameterKITOZER Product AdvantageIndustry StandardAdvantage Explanation
Sound Insulation Volume25–35 dB (Standard Grade), 35–45 dB (Professional Grade)≥20 dBMulti-layer composite structure boosts sound insulation by over 25%
Sound Absorption Coefficient≥0.9 (medium & high frequency)≥0.8Gradient-density sound absorption material delivers superior full-frequency sound absorption
Vibration Transmission Loss≥20 dB (Enhanced Grade), ≥25 dB (Professional Grade)≥15 dBPremium vibration isolation materials cut solid-borne sound transmission paths effectively
Sealing PerformanceGap ≤0.5 mm (Professional Grade)≤1.5 mmMulti-layer sealing technology eliminates noise leakage
Fan Noise≤55 dB(A) (Professional Grade)≤70 dB(A)Low-noise fan design reduces secondary noise pollution

9. Product Tender Control Parameters (Marked with Asterisks)

9.1 Core Technical Parameters (Mandatory Compliance)

表格

Tender Control ParameterStandard GradeEnhanced GradeProfessional GradeRemarks
Sound Insulation Enclosure Structure3-layer composite: 1.5 mm steel + 3 mm damping layer + 50 mm sound absorption cotton3-layer composite: 2.0 mm steel + 5 mm damping layer + 80 mm sound absorption cotton3-layer composite: 3.0 mm steel + 8 mm damping layer + 100 mm sound absorption cottonThird-party test report required for verification
Sound Insulation Volume≥25 dB(A)≥30 dB(A)≥35 dB(A)Tested per GB/T 19889.3 standard
Noise Reduction Effect≥15 dB(A)≥25 dB(A)≥35 dB(A)Measured 1 m outside enclosure, excluding background noise interference
Bulk Density of Sound Absorption Material≥48 kg/m³≥64 kg/m³≥80 kg/m³Glass wool/rock wool with fire resistance Grade B1 or above
Sealing PerformanceGap ≤1.5 mmGap ≤1 mmGap ≤0.5 mmMagnetic sealing strips adopted, sealing test report required
Natural Frequency of Vibration Isolation System≤5 Hz≤4 Hz≤2 HzSpring vibration isolators/air flotation platforms, vibration test report required

9.2 Functional Configuration Parameters (Mandatory Compliance)

表格

Tender Control ParameterStandard GradeEnhanced GradeProfessional GradeRemarks
Ventilation & Heat Dissipation SystemBasic fan + noise elimination louverIntelligent temperature-controlled fan + noise elimination louver + silencerDual redundant fans + intelligent temperature control + air intake/exhaust silencersSatisfies equipment heat dissipation; fan noise ≤65 dB(A)
Safety Interlock DeviceOptionalMandatory (door & fan interlock)Mandatory (door interlocks with fan & equipment power supply)Prevents misoperation and protects personnel safety
Observation WindowSingle-layer glassDouble-layer glass installed at 5° tiltTriple-layer glass installed at 5° tiltSound insulation ≥20 dB/30 dB/35 dB, eliminates standing wave resonance
Maintenance DoorSingle door with single-layer sealingSingle door sound lock with double-layer sealingDouble door sound lock with triple-layer sealingSound insulation ≥25 dB/30 dB/35 dB, convenient for equipment maintenance
Electrical Control SystemBasic controlEnhanced control + fault alarmPLC control + touch screen + remote communicationSupports fan, lighting and temperature interlock control

9.3 Quality & Safety Parameters (Mandatory Compliance)

表格

Control ParameterRequirementRemarks
Material Fire Resistance GradeAll materials Grade B1 or aboveFire protection test report required
Outer Shell Protection GradeIP54 or higherResists dust and water for industrial environments
Anti-corrosion PerformanceOuter coating passes ≥480-hour salt spray testSalt spray test report required
Service Life≥10 yearsNo structural deformation or cracking under normal operating conditions
Environmental CertificationCompliant with RoHS and REACH standardsEnvironmental test report required

10. Full Product Noise Reduction Solutions

10.1 Fan Noise Reduction Solution

Applicable Scenarios: Centrifugal fans, axial fans, Roots blowers and other high-noise fan equipment with noise levels of 85–110 dB(A)

Solution Design:

  1. Adopt KZ-GYZ-2000/KZ-GYZ-3000 sound insulation enclosure modules to form fully or partially enclosed structures
  2. Equip KZ-FJ-02/KZ-FJ-03 low-noise fans and KZ-XSB-02/KZ-XSB-03 noise elimination louvers to guarantee airflow ≥1.2 times equipment demand
  3. Install KZ-JZQ-02/KZ-JZT-01 vibration isolation systems to cut vibration transmission paths
  4. Deploy KZ-JXM-02/KZ-JXM-03 sound insulation maintenance doors and KZ-GCC-02/KZ-GCC-03 observation windows for easy operation and maintenance
  5. Integrate KZ-WK-01/KZ-WK-02 intelligent temperature control systems to monitor internal enclosure temperature and adjust fan speed automatically Expected Outcome: 25–40 dB(A) noise reduction, noise ≤75 dB(A) 1 m outside enclosure, compliant with Class II standard of GB12348-2008

10.2 Air Compressor Noise Reduction Solution

Applicable Scenarios: Screw air compressors, piston air compressors with noise levels of 90–115 dB(A); main noise sources: mechanical noise and airflow noise

Solution Design:

  1. Adopt KZ-GYZ-3000 professional-grade enclosure body: 3 mm outer steel plate + 8 mm damping layer + 100 mm gradient-density rock wool to fully block noise
  2. Equip dual KZ-FJ-03 low-noise fans (3000 m³/h airflow) and KZ-XSQ-02 silencers (≥20 dB noise reduction) to eliminate airflow noise
  3. Install KZ-JZT-01 air flotation vibration isolation platforms with vibration transmission loss ≥25 dB to reduce mechanical vibration noise
  4. Deploy KZ-JXM-03 double-door sound lock maintenance doors with triple-layer sealing and sound insulation ≥35 dB to minimize noise leakage during door opening
  5. Integrate KZ-QT-01 gas detection devices to monitor compressed air leakage inside the enclosure and ensure safety Expected Outcome: 30–45 dB(A) noise reduction, noise ≤70 dB(A) 1 m outside enclosure, greatly improving workshop working environments

10.3 Generator Noise Reduction Solution

Applicable Scenarios: Diesel/gasoline/gas generators with noise levels of 95–120 dB(A); main noise sources: engine noise, exhaust noise and cooling fan noise

Solution Design:

  1. Adopt KZ-GYZ-3000 professional fully enclosed enclosure with sound insulation ≥35 dB
  2. Equip dual redundant KZ-FJ-03 low-noise fans and KZ-XSB-03 noise elimination louvers to meet cooling demand, fan noise ≤55 dB(A)
  3. Install KZ-JZQ-02 spring vibration isolators (1000 kg load capacity) to block vibration transmission paths
  4. Deploy KZ-JXM-03 double-door sound lock maintenance doors and KZ-GCC-03 triple-layer observation windows for convenient operation and monitoring
  5. Integrate KZ-WK-02 intelligent temperature control systems (-40~120℃ range) and KZ-JK-01 remote monitoring modules for remote operation & maintenance
  6. Independent exhaust noise elimination system with ≥30 dB noise reduction to resolve exhaust noise Expected Outcome: 35–45 dB(A) noise reduction, noise ≤70 dB(A) 1 m outside enclosure, meets noise standards for indoor machine rooms and outdoor installation

10.4 Punch Press / Crusher Noise Reduction Solution

Applicable Scenarios: Punch presses, crushers, ball mills and other high-impact equipment with noise levels of 100–130 dB(A); main noise sources: impact noise and mechanical noise

Solution Design:

  1. Adopt KZ-GYZ-3000 professional enclosure body with 3 mm thick outer steel plate to enhance structural rigidity and prevent deformation
  2. Equip thickened 8 mm damping layers to suppress low-frequency resonance and eliminate impact noise
  3. Install KZ-JZT-01 air flotation vibration isolation platforms with natural frequency ≤2 Hz and vibration transmission loss ≥25 dB to reduce environmental vibration impact
  4. Deploy KZ-MF-03 professional sealing systems with quadruple magnetic sealing strips and gap ≤0.5 mm to eliminate noise leakage
  5. Integrate KZ-LS-02 safety interlock systems: door body interlocks with equipment power supply, auto power cut when door opens to protect operators Expected Outcome: 35–45 dB(A) noise reduction, noise ≤75 dB(A) 1 m outside enclosure, improves workshop environments and protects employees’ hearing health

11. Full Product Application Cases

11.1 Automobile Manufacturing Industry Case

Project Name: Engine Test Bench Noise Reduction Project for an Automobile Manufacturer

Project Background: Engine testing generates noise up to 98 dB(A), disturbing adjacent workshops and office areas

Solution Adopted: KZ-GYZ-2000 enhanced-grade split sound insulation enclosure, customized split body design matching test bench operating space

Implementation Result: 26 dB(A) noise reduction, noise lowered to 72 dB(A) 1 m outside enclosure, fully compliant with GBZ1-2010 Design Hygiene Standard for Industrial Enterprises

Customer Feedback: Modular design facilitates equipment maintenance; intelligent temperature control guarantees test precision with outstanding noise reduction performance

11.2 Power Industry Case

Project Name: Transformer Noise Reduction Project for a Substation

Project Background: Transformer operating noise reaches 68 dB(A), exceeding factory boundary noise limits and triggering complaints from nearby residents

Solution Adopted: KZ-GYZ-2000 enhanced-grade sound insulation enclosure customized to transformer dimensions with intelligent ventilation systems

Implementation Result: 16 dB(A) noise reduction, factory boundary noise reduced to 52 dB(A), compliant with Class II standard of GB12348-2008

Customer Feedback: Quick installation with no impact on equipment operation; completely resolves noise nuisance issues for residents

11.3 Chemical Industry Case

Project Name: Reactor Noise Reduction Project for a Chemical Plant

Project Background: Agitation noise of reaction kettles hits 95 dB(A); flammable & explosive environment requires explosion-proof noise reduction equipment

Solution Adopted: KZ-GYZ-3000 professional explosion-proof sound insulation enclosure compliant with GB3836 standard, equipped with gas detection devices

Implementation Result: 30 dB(A) noise reduction, noise lowered to 65 dB(A) 1 m outside enclosure, satisfies both explosion-proof and noise reduction requirements

Customer Feedback: Reliable explosion-proof performance and excellent noise reduction, ensures employee safety and comfortable working environments

11.4 Mining Industry Case

Project Name: Ball Mill Noise Reduction Project for a Mine

Project Background: Ball mill operating noise reaches 120 dB(A), severely damaging operators’ hearing health

Solution Adopted: KZ-GYZ-3000 professional fully enclosed sound insulation enclosure equipped with air flotation vibration isolation platforms and dual redundant fan systems

Implementation Result: 40 dB(A) noise reduction, noise lowered to 80 dB(A) 1 m outside enclosure, greatly improving working conditions

Customer Feedback: Robust structure adapts to harsh mining environments; noise reduction effect far exceeds expectations

11.5 Textile Industry Case

Project Name: Air Compressor Station Noise Reduction Project for a Textile Mill

Project Background: Four air compressors operating simultaneously generate noise up to 105 dB(A), disrupting production and harming employee health

Solution Adopted: Four sets of KZ-GYZ-2000 enhanced-grade sound insulation enclosures to wrap each compressor independently, matched with centralized ventilation systems

Implementation Result: 25 dB(A) noise reduction per compressor, overall workshop noise controlled below 75 dB(A), compliant with GBZ1-2010 standard

Customer Feedback: Modular design simplifies maintenance; centralized ventilation guarantees heat dissipation with remarkable noise reduction performance

12. Product Faults & Maintenance Guidelines

12.1 Common Faults & Troubleshooting

表格

Fault TypeFault PhenomenonPossible CausesSolutionsPreventive Measures
Structural DamageEnclosure deformation/cracking, degraded noise reduction effectEquipment collision, material fatigue, foundation settlement1. Repair deformed areas2. Replace damaged modules3. Reinforce foundation1. Install anti-collision devices2. Regular structural inspections3. Optimize foundation design
Sealing System FailureIncreased noise leakage, reduced sound insulationAging/falling sealing strips, widened gaps1. Replace sealing strips2. Re-seal gaps3. Adjust door alignment1. Adopt anti-aging sealing strips2. Regular sealing condition inspections3. Keep door surfaces clean
Ventilation System MalfunctionExcessively high internal enclosure temperature, equipment alarmsFan failure, filter blockage, damaged noise elimination louvers1. Repair/replace fans2. Clean/replace filters3. Repair noise elimination louvers1. Scheduled fan maintenance2. Regular filter cleaning3. Install protective screens
Vibration Isolation System FailureIncreased vibration and noise transmissionDamaged vibration isolators, aging isolation pads1. Replace vibration isolators/pads2. Re-adjust installation positions1. Adopt premium vibration isolation materials2. Regular vibration isolation system inspections3. Control equipment vibration amplitude
Electrical System MalfunctionFan/lighting outage, temperature control failureCircuit faults, damaged controllers, faulty sensors1. Inspect circuit connections2. Repair/replace controllers3. Calibrate/replace sensors1. Adopt premium electrical components2. Regular electrical system inspections3. Complete lightning protection setup

12.2 Daily Maintenance Regulations

12.2.1 Daily Inspection Items

表格

Inspection ItemInspection ContentStandard RequirementHandling Method
Sound Insulation Enclosure AppearanceDeformation, cracking, rust on enclosure bodyNo deformation, cracking or obvious rustRecord abnormalities and arrange timely repair
Sealing SystemAging/falling sealing strips, gap sizeIntact sealing strips, gap ≤1 mmClean sealing strips, adjust door alignment
Ventilation SystemFan operation status, abnormal noiseNormal fan operation with no unusual soundsRecord abnormalities and arrange timely repair
Electrical SystemIndicator light, controller operating statusNormal indicator lights, no controller alarmsRecord abnormalities and arrange timely repair
Temperature MonitoringInternal enclosure temperature, within normal rangeTemperature ≤ maximum allowable equipment temperature +5℃Adjust fan speed to enhance ventilation & heat dissipation

12.2.2 Weekly Inspection Items

表格

Inspection ItemInspection ContentStandard RequirementHandling Method
Sound Absorption MaterialFalling, dampness, contaminationIntact sound absorption material with no dampness or heavy contaminationClean sound absorption material, repair fallen sections
Observation WindowBroken glass, surface stainsUndamaged glass with clear visibilityClean glass, replace broken panels
Maintenance DoorOpening/closing flexibility, sealing performanceSmooth opening/closing with good sealingAdjust door hinges, replace sealing strips
Vibration Isolation SystemDamaged/aged vibration isolators & padsIntact vibration isolation components with no obvious agingRecord abnormalities and schedule replacement
Filter CleaningClogged ventilation filtersNo severe filter blockageClean filters to maintain unobstructed airflow

12.2.3 Monthly Inspection Items

表格

Inspection ItemInspection ContentStandard RequirementHandling Method
Sound Insulation Performance TestNoise value measured 1 m outside enclosureNoise ≤ design value +3 dBInspect sealing system and repair sound bridge leakage
Vibration TestEnclosure vibration amplitudeVibration amplitude ≤ design valueInspect vibration isolation system, adjust installation positions
Full Electrical System InspectionCircuits, controllers, sensorsNo aging circuits, functional controllers, calibrated sensorsOverhaul electrical systems, replace aging components
Safety Interlock DeviceNormal interlock functionAuto shutdown/power cut when door opensAdjust interlock device to ensure full functionality
Anti-corrosion CoatingPeeling/rust on outer coatingIntact coating with no obvious rustRepair coating and reinforce anti-corrosion treatment

12.2.4 Annual Maintenance Items

  1. Full structural inspection of sound insulation enclosures, repair deformed and cracked sections
  2. Replace aging sealing strips, vibration isolation pads and other wearing parts
  3. Clean sound absorption materials, replace heavily contaminated sound absorption layers
  4. Complete overhaul of ventilation systems, replace fan bearings, filters and other components
  5. Calibrate temperature control systems, gas detection devices and other instruments
  6. Conduct sound insulation and vibration tests to confirm compliance with design requirements
  7. Full enclosure cleaning and anti-corrosion treatment

13. Factory Strength & After-sales Service

13.1 Factory Strength

13.1.1 Technical Strength

  • R&D Team: 25-person professional technical team including 6 acoustic engineers, 8 mechanical engineers and 5 electrical engineers, capable of independent acoustic simulation and solution design
  • Technical Certifications: ISO9001 Quality Management System Certification, ISO14001 Environmental Management System Certification, Class II Environmental Engineering Professional Contracting Qualification; multiple products certified by third-party acoustic testing institutions
  • R&D Capacity: Independent R&D of four core noise reduction product categories (sound absorption, insulation, silencing, vibration isolation); over 10 patented technologies for continuous innovation in enclosure design and material application

13.1.2 Production Strength

  • Production Base: 8,000 m² modern manufacturing plant equipped with CNC machining centers, fully automatic sound insulation panel production lines and laser cutting machines
  • Production Capacity: Monthly output of 40 sets of modular sound insulation rooms and 500 m² of sound insulation enclosure panels to meet bulk order demands
  • Quality Control: Strict full-process quality control system covering raw material procurement to finished product delivery, with professional testing at every production stage to guarantee product quality

13.1.3 Project Experience

  • Industry Coverage: Serves 12 industrial sectors including machinery manufacturing, power & energy, auto parts, chemical and mining, with over 2,000 completed projects
  • Project Scale: Delivered multiple large-scale projects including a 100-unit air compressor noise reduction project for an automobile manufacturer and a 50-unit ball mill noise reduction project for a mine
  • International Cooperation: Partners with world-renowned acoustic companies from Germany, the US and other countries to introduce advanced technologies and upgrade product performance

13.2 After-sales Service

13.2.1 Pre-sales Service

  1. Free On-site Survey: Professional engineers arrive on-site within 48 hours to measure noise levels, equipment dimensions and installation space parameters
  2. Customized Solution Design: Custom noise reduction solutions output within 72 hours including noise reduction targets, system configurations and installation plans
  3. Acoustic Simulation Analysis: Professional acoustic software simulation to predict noise reduction performance and optimize solution design
  4. 24-hour Technical Consultation: Round-the-clock technical support to answer all noise control related inquiries

13.2.2 In-sales Service

  1. Fast Delivery: Shipment within 72 hours for standard models; design, production and delivery completed within 15 days for customized projects
  2. Professional Installation: Service outlets across major cities nationwide, installation and commissioning finished within 7 days to ensure normal system operation
  3. Operator Training: Professional operation and maintenance training provided for customers to ensure proper equipment use and maintenance
  4. Acceptance Testing: Sound insulation performance testing conducted post-installation with third-party test reports provided to verify compliance with design standards

13.2.3 After-sales Service

  1. Warranty Period: 1–3 years free warranty; free replacement of all defective components during warranty coverage
  2. Fault Response: Dedicated staff responds within 24 hours upon fault notification; on-site troubleshooting completed within 48 hours
  3. Scheduled Inspection: Two free annual inspections during warranty period to identify and resolve potential hidden faults in advance
  4. Lifetime Maintenance: Cost-based lifelong maintenance service; timely resolution of any post-warranty failures to eliminate long-term operational worries
  5. Spare Parts Supply: Long-term stable supply of all spare parts to guarantee timely replacement of damaged components and continuous equipment operation

14. Conclusion

As a professional noise reduction solution, the KITOZER industrial sound insulation enclosure delivers comprehensive noise protection for industrial high-noise equipment via advanced acoustic design, premium material selection and precision manufacturing technology. The system not only effectively cuts equipment operating noise, improves working environments and protects employees’ hearing health, but also helps enterprises meet industrial noise emission standards and avoid environmental fines and rectification orders.

Adhering to the philosophy of Technological Innovation, Quality First, Customer Oriented, we provide full-process solutions including on-site survey, solution design, manufacturing, installation & commissioning and after-sales service. Whether you face noise issues from power equipment such as fans, air compressors and generators, or high-impact equipment including punch presses and crushers, KITOZER can provide optimal noise reduction solutions to enable quiet, safe and efficient factory operation.

Choosing KITOZER industrial sound insulation enclosures means choosing professionalism, quality and reliability. We look forward to cooperating with you to build quiet industrial environments and support sustainable enterprise development.

15. Search Keywords, SEO & Tags

15.1 Core Keywords

Industrial Sound Insulation Enclosure, Industrial Noise Reduction Equipment, KITOZER Sound Insulation Enclosure, Fan Sound Insulation Enclosure, Air Compressor Sound Insulation Enclosure, Generator Sound Insulation Enclosure, Punch Press Sound Insulation Enclosure, Crusher Sound Insulation Enclosure, Industrial Noise Control, Custom Sound Insulation Enclosure

15.2 Long-tail Keywords

Industrial Sound Insulation Enclosure Manufacturer, Industrial Sound Insulation Enclosure Price, Custom Industrial Sound Insulation Enclosure, Industrial Sound Insulation Enclosure Installation, Noise Reduction Effect of Industrial Sound Insulation Enclosure, Explosion-proof Industrial Sound Insulation Enclosure, Anti-corrosion Industrial Sound Insulation Enclosure, High-temperature Industrial Sound Insulation Enclosure, Modular Industrial Sound Insulation Enclosure, Detachable Industrial Sound Insulation Enclosure

15.3 SEO Tags

  • Title Tag: KITOZER Industrial Sound Insulation Enclosure | Industrial Noise Reduction Equipment | Professional Noise Control Solutions
  • Description Tag: KITOZER industrial sound insulation enclosures deliver professional noise reduction solutions for fans, air compressors, generators and other equipment with 20–45 dB(A) noise reduction. Custom design and installation available to meet industrial noise emission standards.
  • Keyword Tag: Industrial Sound Insulation Enclosure, Industrial Noise Reduction Equipment, KITOZER Sound Insulation Enclosure, Fan Sound Insulation Enclosure, Air Compressor Sound Insulation Enclosure, Generator Sound Insulation Enclosure, Industrial Noise Control

15.4 Classification Tags

  • Product Category: Industrial Sound Insulation Enclosure, Noise Control Equipment, Environmental Protection Equipment
  • Industry Category: Machinery Manufacturing, Power & Energy, Auto Parts, Chemical Industry, Mining, Textile Industry
  • Application Category: Fan Noise Reduction, Air Compressor Noise Reduction, Generator Noise Reduction, Punch Press Noise Reduction, Crusher Noise Reduction, Transformer Noise Reduction
  • Functional Category: Fully Enclosed Sound Insulation Enclosure, Partial Sound Insulation Enclosure, Movable Sound Insulation Enclosure, Explosion-proof Sound Insulation Enclosure, Anti-corrosion Sound Insulation Enclosure
Shopping Cart