Table of Contents
Toggle1. System Overview
The KITOZER industrial sound insulation enclosure is a professional noise control equipment designed based on the acoustic mass law and multi-layer composite structure. It delivers all-round noise reduction solutions for industrial high-noise sources. Adopting a five-step sound insulation chain technology of sound insulation – sound absorption – damping – vibration isolation – sealing, the system effectively suppresses equipment noise with a noise reduction range of 20–40 dB(A). It lowers operational noise of equipment from 90–120 dB(A) to below 75 dB(A), complying with GB12348-2008 Emission Standard for Industrial Enterprises Noise at Boundary and GBZ1-2010 Design Hygiene Standard for Industrial Enterprises.
Built on a modular design concept, the system supports rapid installation and flexible expansion, suitable for a full range of industrial scenarios including high-noise power equipment such as fans, air compressors, generators, water pumps, crushers and ball mills, as well as partial noise reduction for production lines. Integrated with ventilation & heat dissipation, maintenance access and monitoring functions, the enclosure ensures efficient noise control while guaranteeing normal equipment operation and convenient operation.
2. System Components
The KITOZER industrial sound insulation enclosure system consists of the following core assemblies to form a complete noise control system:
表格
| Assembly Category | Core Components | Function Description |
|---|---|---|
| Main Structure System | Sound insulation enclosure body (steel plate + damping layer + sound absorption material + protective panel) | Delivers basic sound insulation performance. The outer steel plate (1.5–3 mm) provides rigid support; the damping layer restrains resonance; sound absorption material (bulk density ≥48 kg/m³) absorbs reverberant noise inside the enclosure |
| Sealing System | Triple magnetic sealing strips, elastic putty plugging, sound lock structure | Blocks noise leakage paths, with door gap ≤1 mm; elastic plugging for wall-penetrating holes; sound lock structure reduces noise leakage when doors are opened |
| Ventilation & Heat Dissipation System | Low-noise fans, noise elimination louvers, intelligent temperature control devices | Satisfies equipment heat dissipation requirements; fan noise ≤60 dB(A); noise elimination louvers provide noise reduction ≥15 dB; temperature control accuracy ±1℃ |
| Vibration Isolation System | Spring vibration isolators (natural frequency ≤5 Hz), rubber vibration isolation pads | Cuts solid-borne sound transmission paths; vibration transmission loss ≥20 dB, lowering structural resonance noise |
| Operation & Maintenance System | Sound insulation maintenance doors, double-layer observation windows (installed at 5° tilt), safety interlock devices | Provides maintenance access for equipment; observation windows deliver sound insulation ≥30 dB; safety interlocks prevent misoperation |
| Electrical Control System | Lighting system, alarm devices, remote monitoring interfaces | Ensures safe operation inside the enclosure; supports docking with factory DCS systems for real-time status monitoring |
| Auxiliary System | Fire protection interfaces, gas detection devices, emergency ventilation outlets | Meets safety requirements for special working conditions; adaptable to explosion-proof, anti-corrosion and harsh environments |
3. System Classification
KITOZER industrial sound insulation enclosures are categorized by application scenarios and technical features as follows:
3.1 Classification by Enclosure Closure Degree
表格
| Type | Structural Features | Noise Reduction Performance | Applicable Scenarios |
|---|---|---|---|
| Fully Enclosed Type | Completely wraps noise sources, equipped with powerful ventilation & heat dissipation systems | Insertion loss: 25–40 dB(A) | Equipment with stable noise sources requiring infrequent operation (large fans, generators) |
| Partially Open Type | Retains observation/operation openings with partial wrapping of noise sources | Insertion loss: 15–25 dB(A) | Equipment requiring frequent intervention (production lines, machine tools) |
| Split Combined Type | Multi-module splicing, fully detachable | Insertion loss: 20–35 dB(A) | Large complex equipment requiring regular major overhauls (compressors, steam turbines) |
3.2 Classification by Structural Form
表格
| Type | Design Features | Advantages | Applicable Scenarios |
|---|---|---|---|
| Fixed Structure | Integrated welding/assembly with stable structure | Good sealing and stable sound insulation effect | Equipment permanently installed at fixed positions |
| Movable/Detachable Type | Modular assembly connected by bolts | Easy disassembly, transportation and reuse | Equipment requiring regular maintenance, temporary noise reduction demands |
| Mobile Type | Equipped with casters/tracks for overall movement | High flexibility, shared by multiple devices | Small equipment, mobile operation scenarios |
3.3 Classification by Noise Reduction Grade
表格
| Grade | Noise Reduction Index | Structural Configuration | Applicable Scenarios |
|---|---|---|---|
| Standard Grade | 15–25 dB(A) noise reduction | Basic composite structure, single-layer sealing | General industrial equipment with noise ≤90 dB(A) |
| Enhanced Grade | 25–35 dB(A) noise reduction | Reinforced composite structure, double-layer sealing + damping layer | Medium-high noise equipment with noise 90–110 dB(A) |
| Professional Grade | 35–45 dB(A) noise reduction | Multi-layer composite structure, multi-sealing + full vibration isolation system | High-noise equipment with noise ≥110 dB(A) (crushers, ball mills) |
3.4 Classification by Special Functions
表格
| Type | Functional Features | Applicable Scenarios |
|---|---|---|
| Explosion-proof Type | Adopts explosion-proof materials and structures, compliant with GB3836 standard | Chemical, mining and other flammable & explosive environments |
| Anti-corrosion Type | Outer shell made of stainless steel/anti-corrosion coating, internal moisture-proof treatment | Coastal, chemical and other corrosive environments |
| High-temperature Type | High-temperature resistant materials, reinforced ventilation system, temperature resistance ≥200℃ | Boilers, melting furnaces and other high-temperature equipment |
| Low-temperature Type | Thermal insulation layer design, temperature resistance ≤-40℃ | Cold storage, low-temperature test equipment |
4. System Schematic Diagrams
4.1 Noise Reduction Principle Diagram
Noise Source → Inner Sound Absorption Material (sound absorption coefficient ≥0.9) → Damping Layer (resonance suppression) → Outer Steel Plate (sound insulation ≥30 dB) → Sealing System (sound bridge blocking) → Vibration Isolation System (solid-borne sound cut-off) → Ambient Environment (noise reduced by 20–40 dB)
4.2 Structural Principle Diagram
External Environment ← Outer Steel Plate (1.5–3 mm galvanized steel) ← Damping Coating (thickness ≥1 mm) ← Sound Absorption Layer (50–100 mm gradient-density sound absorption cotton) ← Perforated Protective Panel (perforation rate ≥20%) ← Internal Noise Source
4.3 Ventilation & Heat Dissipation System Principle Diagram
Hot air inside enclosure → Noise elimination louver (noise reduction ≥15 dB) → Low-noise fan (noise ≤60 dB(A)) → Exhaust silencer → Outdoor air
Cold outdoor air → Air intake silencer → Noise elimination louver → Inside enclosure
4.4 Vibration Isolation System Principle Diagram
Equipment vibration → Spring vibration isolator (natural frequency ≤5 Hz) → Vibration isolation pad → Ground/base
5. Full System Configuration List (KITOZER Brand, Divided into Low/Medium/High Grades)
5.1 Standard Grade Configuration List (Low Configuration)
表格
| No. | Product Name | Model & Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Sound Insulation Enclosure Module | KZ-GYZ-1000 | Outer 1.5 mm galvanized steel plate, middle 3 mm damping coating, inner 50 mm glass wool (bulk density 48 kg/m³), protective panel with 20% perforation rate | 4 | Block | KITOZER | Basic sound insulation structure, 15–20 dB noise reduction |
| 2 | Sound Insulation Maintenance Door | KZ-JXM-01 | Size 800×1800 mm, single-layer sealing, sound insulation ≥25 dB | 1 | Set | KITOZER | Standard configuration, no observation window |
| 3 | Observation Window | KZ-GCC-01 | Size 400×600 mm, single-layer tempered glass, sound insulation ≥20 dB | 1 | Piece | KITOZER | Basic observation function |
| 4 | Spring Vibration Isolator | KZ-JZQ-01 | Load capacity 500 kg, natural frequency ≤5 Hz, damping ratio ≥0.05 | 4 | Piece | KITOZER | Basic vibration isolation, vibration transmission loss ≥15 dB |
| 5 | Noise Elimination Louver | KZ-XSB-01 | Size 500×500 mm, noise reduction ≥12 dB, airflow resistance ≤100 Pa | 2 | Piece | KITOZER | Basic ventilation noise elimination |
| 6 | Low-noise Fan | KZ-FJ-01 | Air volume 1000 m³/h, wind pressure 200 Pa, noise ≤65 dB(A) | 1 | Unit | KITOZER | Basic heat dissipation demand |
| 7 | Sealing System | KZ-MF-01 | Single-layer magnetic sealing strips, gap ≤1.5 mm | 1 | Set | KITOZER | Basic sealing to prevent noise leakage |
| 8 | Lighting System | KZ-ZM-01 | 2×20 W explosion-proof fluorescent lamp, illuminance ≥200 Lux | 1 | Set | KITOZER | Basic lighting demand |
| 9 | Electrical Control Box | KZ-KZ-01 | Includes fan control, lighting control | 1 | Unit | KITOZER | Basic electrical control |
5.2 Enhanced Grade Configuration List (Medium Configuration)
表格
| No. | Product Name | Model & Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Sound Insulation Enclosure Module | KZ-GYZ-2000 | Outer 2.0 mm galvanized steel plate, middle 5 mm damping coating, inner 80 mm gradient-density glass wool (bulk density 64 kg/m³), protective panel with 25% perforation rate | 4 | Block | KITOZER | Reinforced sound insulation structure, 25–30 dB noise reduction |
| 2 | Sound Insulation Maintenance Door | KZ-JXM-02 | Size 800×1800 mm, single-door sound lock structure, double-layer sealing, sound insulation ≥30 dB | 1 | Set | KITOZER | Enhanced sealing, reduces noise leakage during door opening |
| 3 | Observation Window | KZ-GCC-02 | Size 400×600 mm, double-layer tempered glass installed at 5° tilt, sound insulation ≥30 dB | 1 | Piece | KITOZER | Eliminates standing wave resonance, improves sound insulation performance |
| 4 | Spring Vibration Isolator | KZ-JZQ-02 | Load capacity 1000 kg, natural frequency ≤4 Hz, damping ratio ≥0.08 | 4 | Piece | KITOZER | Enhanced vibration isolation, vibration transmission loss ≥20 dB |
| 5 | Noise Elimination Louver | KZ-XSB-02 | Size 600×600 mm, noise reduction ≥15 dB, airflow resistance ≤80 Pa | 2 | Piece | KITOZER | Enhanced ventilation noise elimination effect |
| 6 | Low-noise Fan | KZ-FJ-02 | Air volume 2000 m³/h, wind pressure 300 Pa, noise ≤60 dB(A) | 1 | Unit | KITOZER | Enhanced heat dissipation, low-noise design |
| 7 | Intelligent Temperature Control Device | KZ-WK-01 | Temperature range -20~80℃, control accuracy ±1℃, interlocks fan start/stop | 1 | Unit | KITOZER | Intelligent heat dissipation control, energy-saving and high-efficiency |
| 8 | Sealing System | KZ-MF-02 | Triple magnetic sealing strips, gap ≤1 mm, elastic putty plugging for wall-penetrating holes | 1 | Set | KITOZER | Enhanced sealing, eliminates sound bridge leakage |
| 9 | Lighting System | KZ-ZM-02 | 2×36 W explosion-proof fluorescent lamp, illuminance ≥300 Lux, emergency lighting function | 1 | Set | KITOZER | Enhanced lighting with emergency backup |
| 10 | Electrical Control Box | KZ-KZ-02 | Fan control, lighting control, temperature interlock, fault alarm | 1 | Unit | KITOZER | Enhanced electrical control with early fault warning |
| 11 | Safety Interlock Device | KZ-LS-01 | Door body interlocks with fan, fan auto-shuts down when door opens | 1 | Set | KITOZER | Ensures operation safety |
| 12 | Exhaust Silencer | KZ-XSQ-01 | Noise reduction ≥15 dB, compatible with fan interfaces | 1 | Piece | KITOZER | Further reduces exhaust noise |
5.3 Professional Grade Configuration List (High Configuration)
表格
| No. | Product Name | Model & Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Sound Insulation Enclosure Module | KZ-GYZ-3000 | Outer 3.0 mm galvanized steel plate, middle 8 mm damping coating, inner 100 mm gradient-density rock wool (bulk density 80 kg/m³), protective panel with 30% perforation rate | 4 | Block | KITOZER | Professional sound insulation structure, 35–45 dB noise reduction |
| 2 | Sound Insulation Maintenance Door | KZ-JXM-03 | Size 1000×2000 mm, double-door sound lock structure, triple-layer sealing, sound insulation ≥35 dB | 1 | Set | KITOZER | Professional-grade sealing, noise leakage ≤5 dB when door opens |
| 3 | Observation Window | KZ-GCC-03 | Size 500×800 mm, triple-layer tempered glass installed at 5° tilt, sound insulation ≥35 dB | 1 | Piece | KITOZER | Professional observation window, eliminates standing wave resonance |
| 4 | Air Flotation Vibration Isolation Platform | KZ-JZT-01 | Load capacity 2000 kg, natural frequency ≤2 Hz, vibration transmission loss ≥25 dB | 1 | Unit | KITOZER | Professional vibration isolation for precision equipment |
| 5 | Noise Elimination Louver | KZ-XSB-03 | Size 800×800 mm, noise reduction ≥20 dB, airflow resistance ≤60 Pa | 2 | Piece | KITOZER | Professional ventilation noise elimination |
| 6 | Low-noise Fan | KZ-FJ-03 | Air volume 3000 m³/h, wind pressure 400 Pa, noise ≤55 dB(A) | 2 | Unit | KITOZER | Dual-fan redundant design to guarantee heat dissipation |
| 7 | Intelligent Temperature Control System | KZ-WK-02 | Temperature range -40~120℃, control accuracy ±0.5℃, supports remote monitoring | 1 | Set | KITOZER | Professional temperature control, compatible with high-temperature equipment |
| 8 | Sealing System | KZ-MF-03 | Quadruple magnetic sealing strips, gap ≤0.5 mm, liquid sealant plugging, sound bridge blocking design | 1 | Set | KITOZER | Professional sealing, eliminates all noise leakage |
| 9 | Lighting System | KZ-ZM-03 | 4×36 W explosion-proof LED lamps, illuminance ≥500 Lux, emergency lighting + backup power supply | 1 | Set | KITOZER | Professional lighting with emergency backup |
| 10 | Electrical Control Cabinet | KZ-KZ-03 | PLC control, touch screen operation, fan frequency conversion control, temperature interlock, fault alarm, remote communication interface | 1 | Unit | KITOZER | Professional electrical control, supports DCS docking |
| 11 | Safety Interlock System | KZ-LS-02 | Door body interlocks with fans and equipment power supply, auto-shutdown & power cut when door opens | 1 | Set | KITOZER | Professional safety protection |
| 12 | Air Intake & Exhaust Silencers | KZ-XSQ-02 | Noise reduction ≥20 dB, compatible with dual fan interfaces | 2 | Piece | KITOZER | Professional noise elimination to further cut airflow noise |
| 13 | Gas Detection Device | KZ-QT-01 | Detects CO, O₂ and flammable gas with adjustable alarm thresholds | 1 | Set | KITOZER | Meets safety demands of fully enclosed spaces |
| 14 | Emergency Ventilation System | KZ-TF-01 | Independent emergency fan, auto-start upon power failure | 1 | Set | KITOZER | Protects personnel safety |
| 15 | Remote Monitoring Module | KZ-JK-01 | Supports mobile APP/PC remote monitoring of temperature, noise and fan status | 1 | Set | KITOZER | Professional operation & maintenance management |
6. Full Product Technical Parameters
6.1 Sound Insulation Enclosure Module Technical Parameters
表格
| Model | Outer Steel Thickness | Damping Layer Thickness | Sound Absorption Layer Thickness | Sound Absorption Material | Bulk Density | Perforation Rate | Sound Insulation Volume | Noise Reduction Effect | Applicable Noise Range |
|---|---|---|---|---|---|---|---|---|---|
| KZ-GYZ-1000 | 1.5 mm | 3 mm | 50 mm | Glass Wool | 48 kg/m³ | 20% | ≥25 dB | 15–20 dB | ≤90 dB(A) |
| KZ-GYZ-2000 | 2.0 mm | 5 mm | 80 mm | Gradient Glass Wool | 64 kg/m³ | 25% | ≥30 dB | 25–30 dB | 90–110 dB(A) |
| KZ-GYZ-3000 | 3.0 mm | 8 mm | 100 mm | Gradient Rock Wool | 80 kg/m³ | 30% | ≥35 dB | 35–45 dB | ≥110 dB(A) |
6.2 Sound Insulation Maintenance Door Technical Parameters
表格
| Model | Size (mm) | Structural Form | Sealing Layers | Sound Insulation Volume | Applicable Scenarios |
|---|---|---|---|---|---|
| KZ-JXM-01 | 800×1800 | Single Door | 1 | ≥25 dB | Standard Grade Configuration |
| KZ-JXM-02 | 800×1800 | Single Door with Sound Lock | 2 | ≥30 dB | Enhanced Grade Configuration |
| KZ-JXM-03 | 1000×2000 | Double Door with Sound Lock | 3 | ≥35 dB | Professional Grade Configuration |
6.3 Observation Window Technical Parameters
表格
| Model | Size (mm) | Glass Layers | Installation Angle | Sound Insulation Volume | Applicable Scenarios |
|---|---|---|---|---|---|
| KZ-GCC-01 | 400×600 | Single Layer | 0° | ≥20 dB | Standard Grade Configuration |
| KZ-GCC-02 | 400×600 | Double Layer | 5° | ≥30 dB | Enhanced Grade, eliminates standing waves |
| KZ-GCC-03 | 500×800 | Triple Layer | 5° | ≥35 dB | Professional Grade, high sound insulation demand |
6.4 Vibration Isolation System Technical Parameters
表格
| Model | Type | Load Capacity (kg) | Natural Frequency (Hz) | Damping Ratio | Vibration Transmission Loss | Applicable Scenarios |
|---|---|---|---|---|---|---|
| KZ-JZQ-01 | Spring Vibration Isolator | 500 | ≤5 | ≥0.05 | ≥15 dB | Standard Grade Configuration |
| KZ-JZQ-02 | Spring Vibration Isolator | 1000 | ≤4 | ≥0.08 | ≥20 dB | Enhanced Grade Configuration |
| KZ-JZT-01 | Air Flotation Vibration Isolation Platform | 2000 | ≤2 | ≥0.10 | ≥25 dB | Professional Grade, precision equipment |
6.5 Ventilation & Heat Dissipation System Technical Parameters
表格
| Model | Type | Size (mm) | Air Volume (m³/h) | Wind Pressure (Pa) | Noise Reduction (dB) | Noise (dB(A)) | Applicable Scenarios |
|---|---|---|---|---|---|---|---|
| KZ-XSB-01 | Noise Elimination Louver | 500×500 | – | – | ≥12 | – | Standard Grade Configuration |
| KZ-XSB-02 | Noise Elimination Louver | 600×600 | – | – | ≥15 | – | Enhanced Grade Configuration |
| KZ-XSB-03 | Noise Elimination Louver | 800×800 | – | – | ≥20 | – | Professional Grade Configuration |
| KZ-FJ-01 | Low-noise Fan | – | 1000 | 200 | – | ≤65 | Standard Grade Configuration |
| KZ-FJ-02 | Low-noise Fan | – | 2000 | 300 | – | ≤60 | Enhanced Grade Configuration |
| KZ-FJ-03 | Low-noise Fan | – | 3000 | 400 | – | ≤55 | Professional Grade Configuration |
| KZ-XSQ-01 | Silencer | – | – | – | ≥15 | – | Enhanced Grade Configuration |
| KZ-XSQ-02 | Silencer | – | – | – | ≥20 | – | Professional Grade Configuration |
6.6 Electrical Control System Technical Parameters
表格
| Model | Control Functions | Temperature Range | Control Accuracy | Communication Interface | Applicable Scenarios |
|---|---|---|---|---|---|
| KZ-KZ-01 | Fan + Lighting Control | – | – | – | Standard Grade Configuration |
| KZ-KZ-02 | Fan + Lighting + Temperature Control + Alarm | -20~80℃ | ±1℃ | – | Enhanced Grade Configuration |
| KZ-KZ-03 | PLC + Touch Screen + Frequency Conversion + Temperature Control + Alarm + Remote Communication | -40~120℃ | ±0.5℃ | RS485/Ethernet | Professional Grade, DCS docking support |
7. Full Product Application Scope
KITOZER industrial sound insulation enclosure systems are widely used across the following industries and equipment:
7.1 Power Equipment Sector
- Fans: Centrifugal fans, axial fans, Roots blowers, air blowers, noise reduction 20–35 dB, compatible with all airflow and pressure grades
- Compressors: Air compressors, screw compressors, piston compressors, noise reduction 25–35 dB, solves mechanical and airflow noise
- Generators: Diesel, gasoline and gas generators, noise reduction 30–40 dB, suitable for indoor and outdoor installation
- Pumps: Water pumps, oil pumps, mud pumps, noise reduction 20–30 dB, eliminates mechanical and fluid noise
7.2 Manufacturing & Processing Sector
- Machine Tools: Punch presses, milling machines, grinders, lathes, noise reduction 20–30 dB, fits production line layout
- Crushing Equipment: Crushers, ball mills, vibrating screens, noise reduction 30–45 dB, addresses high-noise crushing processes
- Forging & Press Equipment: Forging presses, stamping machines, bending machines, noise reduction 25–35 dB, adapts to workshop environments
- Welding Equipment: Welders, plasma cutting machines, noise reduction 15–25 dB, improves operating environments
7.3 Power & Energy Sector
- Transformers: Power transformers, dry-type transformers, noise reduction 20–30 dB, meets factory boundary noise standards
- Switchgear: High/low voltage switch cabinets, noise reduction 15–25 dB, improves power distribution room environments
- Cooling Towers: Industrial cooling towers, central air conditioning cooling towers, noise reduction 20–30 dB, eliminates fan and water flow noise
7.4 Other Special Sectors
- Chemical Equipment: Reaction kettles, agitators, valves & pumps; explosion-proof and anti-corrosion enclosures available, noise reduction 20–35 dB
- Mining Equipment: Tunneling machines, coal miners, ventilation fans; mobile and explosion-proof enclosures available, noise reduction 25–40 dB
- Medical Equipment: Medical centrifuges, hyperbaric oxygen chambers; clean enclosures available, noise reduction 15–25 dB
- Scientific Research Equipment: High-noise lab equipment, test platforms; precision enclosures available, noise reduction 30–45 dB
8. Full Product Advantages
8.1 Functional Features of Full Product Series
- High-efficiency Noise Reduction Performance: Adopts five-step sound insulation chain technology of sound insulation – sound absorption – damping – vibration isolation – sealing, delivering 20–45 dB(A) noise reduction, exceeding industry standards.
- Multi-layer Composite Structure: Outer 1.5–3 mm galvanized steel for rigid support; middle damping layer suppresses low-frequency resonance; inner gradient-density sound absorption material with sound absorption coefficient ≥0.9 to cover full-frequency noise (low, medium and high).
- Professional Sealing Design: Multi-layer magnetic sealing strips and elastic putty plugging; minimum gap ≤0.5 mm to eliminate sound bridge leakage and guarantee sound insulation performance.
- Intelligent Ventilation & Heat Dissipation: Integrated low-noise fans (≤55 dB) and noise elimination louvers (noise reduction ≥20 dB); intelligent temperature control delivers precise temperature regulation to ensure safe equipment operation.
- Safe & Reliable Design: Equipped with safety interlocks, emergency ventilation systems and gas detection devices to protect operators, compliant with GB/T 19889 series standards.
8.2 Customization Service Capacity
- Full-size Customization: Custom sizes ranging from 0.5 m to 20 m based on equipment dimensions, shape and installation space, adapting to irregular equipment and complex workshop layouts.
- Special Working Condition Customization: Explosion-proof (GB3836 compliant), anti-corrosion, high-temperature (≥200℃ resistance), low-temperature (≤-40℃ resistance) and other special functional customization to meet diverse industrial demands.
- Modular Function Customization: Customizable ventilation volume, sound insulation volume, observation window quantity and maintenance door positions to fit equipment operation and maintenance needs.
- Color & Appearance Customization: Multiple coating color options to match factory corporate image and enhance workshop aesthetics.
8.3 OEM & Confidentiality Services
- OEM/ODM Processing: Supports customer brand customization, full-process OEM service from design to production for bulk procurement demands.
- Strict Confidentiality Agreements: Strict confidentiality of customer technical parameters, design drawings and production processes via formal non-disclosure agreements to protect intellectual property rights.
- Dedicated Project Teams: Dedicated engineering teams assigned to customized projects with one-on-one technical support to guarantee smooth project delivery.
8.4 Spot Supply & Delivery Capacity
- Standard Model Spot Inventory: Standard KZ-GYZ-1000/2000/3000 models available in stock with shipment within 72 hours for urgent noise reduction demands.
- Fast Custom Delivery: Modular production for customized projects; design, production and delivery completed within 15 days, far faster than industry average lead times.
- Nationwide Installation Service: Service outlets across major cities nationwide; on-site survey within 48 hours, installation and commissioning completed within 7 days.
8.5 Full Series Technical Parameter Advantages
表格
| Technical Parameter | KITOZER Product Advantage | Industry Standard | Advantage Explanation |
|---|---|---|---|
| Sound Insulation Volume | 25–35 dB (Standard Grade), 35–45 dB (Professional Grade) | ≥20 dB | Multi-layer composite structure boosts sound insulation by over 25% |
| Sound Absorption Coefficient | ≥0.9 (medium & high frequency) | ≥0.8 | Gradient-density sound absorption material delivers superior full-frequency sound absorption |
| Vibration Transmission Loss | ≥20 dB (Enhanced Grade), ≥25 dB (Professional Grade) | ≥15 dB | Premium vibration isolation materials cut solid-borne sound transmission paths effectively |
| Sealing Performance | Gap ≤0.5 mm (Professional Grade) | ≤1.5 mm | Multi-layer sealing technology eliminates noise leakage |
| Fan Noise | ≤55 dB(A) (Professional Grade) | ≤70 dB(A) | Low-noise fan design reduces secondary noise pollution |
9. Product Tender Control Parameters (Marked with Asterisks)
9.1 Core Technical Parameters (Mandatory Compliance)
表格
| Tender Control Parameter | Standard Grade | Enhanced Grade | Professional Grade | Remarks |
|---|---|---|---|---|
| Sound Insulation Enclosure Structure | 3-layer composite: 1.5 mm steel + 3 mm damping layer + 50 mm sound absorption cotton | 3-layer composite: 2.0 mm steel + 5 mm damping layer + 80 mm sound absorption cotton | 3-layer composite: 3.0 mm steel + 8 mm damping layer + 100 mm sound absorption cotton | Third-party test report required for verification |
| Sound Insulation Volume | ≥25 dB(A) | ≥30 dB(A) | ≥35 dB(A) | Tested per GB/T 19889.3 standard |
| Noise Reduction Effect | ≥15 dB(A) | ≥25 dB(A) | ≥35 dB(A) | Measured 1 m outside enclosure, excluding background noise interference |
| Bulk Density of Sound Absorption Material | ≥48 kg/m³ | ≥64 kg/m³ | ≥80 kg/m³ | Glass wool/rock wool with fire resistance Grade B1 or above |
| Sealing Performance | Gap ≤1.5 mm | Gap ≤1 mm | Gap ≤0.5 mm | Magnetic sealing strips adopted, sealing test report required |
| Natural Frequency of Vibration Isolation System | ≤5 Hz | ≤4 Hz | ≤2 Hz | Spring vibration isolators/air flotation platforms, vibration test report required |
9.2 Functional Configuration Parameters (Mandatory Compliance)
表格
| Tender Control Parameter | Standard Grade | Enhanced Grade | Professional Grade | Remarks |
|---|---|---|---|---|
| Ventilation & Heat Dissipation System | Basic fan + noise elimination louver | Intelligent temperature-controlled fan + noise elimination louver + silencer | Dual redundant fans + intelligent temperature control + air intake/exhaust silencers | Satisfies equipment heat dissipation; fan noise ≤65 dB(A) |
| Safety Interlock Device | Optional | Mandatory (door & fan interlock) | Mandatory (door interlocks with fan & equipment power supply) | Prevents misoperation and protects personnel safety |
| Observation Window | Single-layer glass | Double-layer glass installed at 5° tilt | Triple-layer glass installed at 5° tilt | Sound insulation ≥20 dB/30 dB/35 dB, eliminates standing wave resonance |
| Maintenance Door | Single door with single-layer sealing | Single door sound lock with double-layer sealing | Double door sound lock with triple-layer sealing | Sound insulation ≥25 dB/30 dB/35 dB, convenient for equipment maintenance |
| Electrical Control System | Basic control | Enhanced control + fault alarm | PLC control + touch screen + remote communication | Supports fan, lighting and temperature interlock control |
9.3 Quality & Safety Parameters (Mandatory Compliance)
表格
| Control Parameter | Requirement | Remarks |
|---|---|---|
| Material Fire Resistance Grade | All materials Grade B1 or above | Fire protection test report required |
| Outer Shell Protection Grade | IP54 or higher | Resists dust and water for industrial environments |
| Anti-corrosion Performance | Outer coating passes ≥480-hour salt spray test | Salt spray test report required |
| Service Life | ≥10 years | No structural deformation or cracking under normal operating conditions |
| Environmental Certification | Compliant with RoHS and REACH standards | Environmental test report required |
10. Full Product Noise Reduction Solutions
10.1 Fan Noise Reduction Solution
Applicable Scenarios: Centrifugal fans, axial fans, Roots blowers and other high-noise fan equipment with noise levels of 85–110 dB(A)
Solution Design:
- Adopt KZ-GYZ-2000/KZ-GYZ-3000 sound insulation enclosure modules to form fully or partially enclosed structures
- Equip KZ-FJ-02/KZ-FJ-03 low-noise fans and KZ-XSB-02/KZ-XSB-03 noise elimination louvers to guarantee airflow ≥1.2 times equipment demand
- Install KZ-JZQ-02/KZ-JZT-01 vibration isolation systems to cut vibration transmission paths
- Deploy KZ-JXM-02/KZ-JXM-03 sound insulation maintenance doors and KZ-GCC-02/KZ-GCC-03 observation windows for easy operation and maintenance
- Integrate KZ-WK-01/KZ-WK-02 intelligent temperature control systems to monitor internal enclosure temperature and adjust fan speed automatically Expected Outcome: 25–40 dB(A) noise reduction, noise ≤75 dB(A) 1 m outside enclosure, compliant with Class II standard of GB12348-2008
10.2 Air Compressor Noise Reduction Solution
Applicable Scenarios: Screw air compressors, piston air compressors with noise levels of 90–115 dB(A); main noise sources: mechanical noise and airflow noise
Solution Design:
- Adopt KZ-GYZ-3000 professional-grade enclosure body: 3 mm outer steel plate + 8 mm damping layer + 100 mm gradient-density rock wool to fully block noise
- Equip dual KZ-FJ-03 low-noise fans (3000 m³/h airflow) and KZ-XSQ-02 silencers (≥20 dB noise reduction) to eliminate airflow noise
- Install KZ-JZT-01 air flotation vibration isolation platforms with vibration transmission loss ≥25 dB to reduce mechanical vibration noise
- Deploy KZ-JXM-03 double-door sound lock maintenance doors with triple-layer sealing and sound insulation ≥35 dB to minimize noise leakage during door opening
- Integrate KZ-QT-01 gas detection devices to monitor compressed air leakage inside the enclosure and ensure safety Expected Outcome: 30–45 dB(A) noise reduction, noise ≤70 dB(A) 1 m outside enclosure, greatly improving workshop working environments
10.3 Generator Noise Reduction Solution
Applicable Scenarios: Diesel/gasoline/gas generators with noise levels of 95–120 dB(A); main noise sources: engine noise, exhaust noise and cooling fan noise
Solution Design:
- Adopt KZ-GYZ-3000 professional fully enclosed enclosure with sound insulation ≥35 dB
- Equip dual redundant KZ-FJ-03 low-noise fans and KZ-XSB-03 noise elimination louvers to meet cooling demand, fan noise ≤55 dB(A)
- Install KZ-JZQ-02 spring vibration isolators (1000 kg load capacity) to block vibration transmission paths
- Deploy KZ-JXM-03 double-door sound lock maintenance doors and KZ-GCC-03 triple-layer observation windows for convenient operation and monitoring
- Integrate KZ-WK-02 intelligent temperature control systems (-40~120℃ range) and KZ-JK-01 remote monitoring modules for remote operation & maintenance
- Independent exhaust noise elimination system with ≥30 dB noise reduction to resolve exhaust noise Expected Outcome: 35–45 dB(A) noise reduction, noise ≤70 dB(A) 1 m outside enclosure, meets noise standards for indoor machine rooms and outdoor installation
10.4 Punch Press / Crusher Noise Reduction Solution
Applicable Scenarios: Punch presses, crushers, ball mills and other high-impact equipment with noise levels of 100–130 dB(A); main noise sources: impact noise and mechanical noise
Solution Design:
- Adopt KZ-GYZ-3000 professional enclosure body with 3 mm thick outer steel plate to enhance structural rigidity and prevent deformation
- Equip thickened 8 mm damping layers to suppress low-frequency resonance and eliminate impact noise
- Install KZ-JZT-01 air flotation vibration isolation platforms with natural frequency ≤2 Hz and vibration transmission loss ≥25 dB to reduce environmental vibration impact
- Deploy KZ-MF-03 professional sealing systems with quadruple magnetic sealing strips and gap ≤0.5 mm to eliminate noise leakage
- Integrate KZ-LS-02 safety interlock systems: door body interlocks with equipment power supply, auto power cut when door opens to protect operators Expected Outcome: 35–45 dB(A) noise reduction, noise ≤75 dB(A) 1 m outside enclosure, improves workshop environments and protects employees’ hearing health
11. Full Product Application Cases
11.1 Automobile Manufacturing Industry Case
Project Name: Engine Test Bench Noise Reduction Project for an Automobile Manufacturer
Project Background: Engine testing generates noise up to 98 dB(A), disturbing adjacent workshops and office areas
Solution Adopted: KZ-GYZ-2000 enhanced-grade split sound insulation enclosure, customized split body design matching test bench operating space
Implementation Result: 26 dB(A) noise reduction, noise lowered to 72 dB(A) 1 m outside enclosure, fully compliant with GBZ1-2010 Design Hygiene Standard for Industrial Enterprises
Customer Feedback: Modular design facilitates equipment maintenance; intelligent temperature control guarantees test precision with outstanding noise reduction performance
11.2 Power Industry Case
Project Name: Transformer Noise Reduction Project for a Substation
Project Background: Transformer operating noise reaches 68 dB(A), exceeding factory boundary noise limits and triggering complaints from nearby residents
Solution Adopted: KZ-GYZ-2000 enhanced-grade sound insulation enclosure customized to transformer dimensions with intelligent ventilation systems
Implementation Result: 16 dB(A) noise reduction, factory boundary noise reduced to 52 dB(A), compliant with Class II standard of GB12348-2008
Customer Feedback: Quick installation with no impact on equipment operation; completely resolves noise nuisance issues for residents
11.3 Chemical Industry Case
Project Name: Reactor Noise Reduction Project for a Chemical Plant
Project Background: Agitation noise of reaction kettles hits 95 dB(A); flammable & explosive environment requires explosion-proof noise reduction equipment
Solution Adopted: KZ-GYZ-3000 professional explosion-proof sound insulation enclosure compliant with GB3836 standard, equipped with gas detection devices
Implementation Result: 30 dB(A) noise reduction, noise lowered to 65 dB(A) 1 m outside enclosure, satisfies both explosion-proof and noise reduction requirements
Customer Feedback: Reliable explosion-proof performance and excellent noise reduction, ensures employee safety and comfortable working environments
11.4 Mining Industry Case
Project Name: Ball Mill Noise Reduction Project for a Mine
Project Background: Ball mill operating noise reaches 120 dB(A), severely damaging operators’ hearing health
Solution Adopted: KZ-GYZ-3000 professional fully enclosed sound insulation enclosure equipped with air flotation vibration isolation platforms and dual redundant fan systems
Implementation Result: 40 dB(A) noise reduction, noise lowered to 80 dB(A) 1 m outside enclosure, greatly improving working conditions
Customer Feedback: Robust structure adapts to harsh mining environments; noise reduction effect far exceeds expectations
11.5 Textile Industry Case
Project Name: Air Compressor Station Noise Reduction Project for a Textile Mill
Project Background: Four air compressors operating simultaneously generate noise up to 105 dB(A), disrupting production and harming employee health
Solution Adopted: Four sets of KZ-GYZ-2000 enhanced-grade sound insulation enclosures to wrap each compressor independently, matched with centralized ventilation systems
Implementation Result: 25 dB(A) noise reduction per compressor, overall workshop noise controlled below 75 dB(A), compliant with GBZ1-2010 standard
Customer Feedback: Modular design simplifies maintenance; centralized ventilation guarantees heat dissipation with remarkable noise reduction performance
12. Product Faults & Maintenance Guidelines
12.1 Common Faults & Troubleshooting
表格
| Fault Type | Fault Phenomenon | Possible Causes | Solutions | Preventive Measures |
|---|---|---|---|---|
| Structural Damage | Enclosure deformation/cracking, degraded noise reduction effect | Equipment collision, material fatigue, foundation settlement | 1. Repair deformed areas2. Replace damaged modules3. Reinforce foundation | 1. Install anti-collision devices2. Regular structural inspections3. Optimize foundation design |
| Sealing System Failure | Increased noise leakage, reduced sound insulation | Aging/falling sealing strips, widened gaps | 1. Replace sealing strips2. Re-seal gaps3. Adjust door alignment | 1. Adopt anti-aging sealing strips2. Regular sealing condition inspections3. Keep door surfaces clean |
| Ventilation System Malfunction | Excessively high internal enclosure temperature, equipment alarms | Fan failure, filter blockage, damaged noise elimination louvers | 1. Repair/replace fans2. Clean/replace filters3. Repair noise elimination louvers | 1. Scheduled fan maintenance2. Regular filter cleaning3. Install protective screens |
| Vibration Isolation System Failure | Increased vibration and noise transmission | Damaged vibration isolators, aging isolation pads | 1. Replace vibration isolators/pads2. Re-adjust installation positions | 1. Adopt premium vibration isolation materials2. Regular vibration isolation system inspections3. Control equipment vibration amplitude |
| Electrical System Malfunction | Fan/lighting outage, temperature control failure | Circuit faults, damaged controllers, faulty sensors | 1. Inspect circuit connections2. Repair/replace controllers3. Calibrate/replace sensors | 1. Adopt premium electrical components2. Regular electrical system inspections3. Complete lightning protection setup |
12.2 Daily Maintenance Regulations
12.2.1 Daily Inspection Items
表格
| Inspection Item | Inspection Content | Standard Requirement | Handling Method |
|---|---|---|---|
| Sound Insulation Enclosure Appearance | Deformation, cracking, rust on enclosure body | No deformation, cracking or obvious rust | Record abnormalities and arrange timely repair |
| Sealing System | Aging/falling sealing strips, gap size | Intact sealing strips, gap ≤1 mm | Clean sealing strips, adjust door alignment |
| Ventilation System | Fan operation status, abnormal noise | Normal fan operation with no unusual sounds | Record abnormalities and arrange timely repair |
| Electrical System | Indicator light, controller operating status | Normal indicator lights, no controller alarms | Record abnormalities and arrange timely repair |
| Temperature Monitoring | Internal enclosure temperature, within normal range | Temperature ≤ maximum allowable equipment temperature +5℃ | Adjust fan speed to enhance ventilation & heat dissipation |
12.2.2 Weekly Inspection Items
表格
| Inspection Item | Inspection Content | Standard Requirement | Handling Method |
|---|---|---|---|
| Sound Absorption Material | Falling, dampness, contamination | Intact sound absorption material with no dampness or heavy contamination | Clean sound absorption material, repair fallen sections |
| Observation Window | Broken glass, surface stains | Undamaged glass with clear visibility | Clean glass, replace broken panels |
| Maintenance Door | Opening/closing flexibility, sealing performance | Smooth opening/closing with good sealing | Adjust door hinges, replace sealing strips |
| Vibration Isolation System | Damaged/aged vibration isolators & pads | Intact vibration isolation components with no obvious aging | Record abnormalities and schedule replacement |
| Filter Cleaning | Clogged ventilation filters | No severe filter blockage | Clean filters to maintain unobstructed airflow |
12.2.3 Monthly Inspection Items
表格
| Inspection Item | Inspection Content | Standard Requirement | Handling Method |
|---|---|---|---|
| Sound Insulation Performance Test | Noise value measured 1 m outside enclosure | Noise ≤ design value +3 dB | Inspect sealing system and repair sound bridge leakage |
| Vibration Test | Enclosure vibration amplitude | Vibration amplitude ≤ design value | Inspect vibration isolation system, adjust installation positions |
| Full Electrical System Inspection | Circuits, controllers, sensors | No aging circuits, functional controllers, calibrated sensors | Overhaul electrical systems, replace aging components |
| Safety Interlock Device | Normal interlock function | Auto shutdown/power cut when door opens | Adjust interlock device to ensure full functionality |
| Anti-corrosion Coating | Peeling/rust on outer coating | Intact coating with no obvious rust | Repair coating and reinforce anti-corrosion treatment |
12.2.4 Annual Maintenance Items
- Full structural inspection of sound insulation enclosures, repair deformed and cracked sections
- Replace aging sealing strips, vibration isolation pads and other wearing parts
- Clean sound absorption materials, replace heavily contaminated sound absorption layers
- Complete overhaul of ventilation systems, replace fan bearings, filters and other components
- Calibrate temperature control systems, gas detection devices and other instruments
- Conduct sound insulation and vibration tests to confirm compliance with design requirements
- Full enclosure cleaning and anti-corrosion treatment
13. Factory Strength & After-sales Service
13.1 Factory Strength
13.1.1 Technical Strength
- R&D Team: 25-person professional technical team including 6 acoustic engineers, 8 mechanical engineers and 5 electrical engineers, capable of independent acoustic simulation and solution design
- Technical Certifications: ISO9001 Quality Management System Certification, ISO14001 Environmental Management System Certification, Class II Environmental Engineering Professional Contracting Qualification; multiple products certified by third-party acoustic testing institutions
- R&D Capacity: Independent R&D of four core noise reduction product categories (sound absorption, insulation, silencing, vibration isolation); over 10 patented technologies for continuous innovation in enclosure design and material application
13.1.2 Production Strength
- Production Base: 8,000 m² modern manufacturing plant equipped with CNC machining centers, fully automatic sound insulation panel production lines and laser cutting machines
- Production Capacity: Monthly output of 40 sets of modular sound insulation rooms and 500 m² of sound insulation enclosure panels to meet bulk order demands
- Quality Control: Strict full-process quality control system covering raw material procurement to finished product delivery, with professional testing at every production stage to guarantee product quality
13.1.3 Project Experience
- Industry Coverage: Serves 12 industrial sectors including machinery manufacturing, power & energy, auto parts, chemical and mining, with over 2,000 completed projects
- Project Scale: Delivered multiple large-scale projects including a 100-unit air compressor noise reduction project for an automobile manufacturer and a 50-unit ball mill noise reduction project for a mine
- International Cooperation: Partners with world-renowned acoustic companies from Germany, the US and other countries to introduce advanced technologies and upgrade product performance
13.2 After-sales Service
13.2.1 Pre-sales Service
- Free On-site Survey: Professional engineers arrive on-site within 48 hours to measure noise levels, equipment dimensions and installation space parameters
- Customized Solution Design: Custom noise reduction solutions output within 72 hours including noise reduction targets, system configurations and installation plans
- Acoustic Simulation Analysis: Professional acoustic software simulation to predict noise reduction performance and optimize solution design
- 24-hour Technical Consultation: Round-the-clock technical support to answer all noise control related inquiries
13.2.2 In-sales Service
- Fast Delivery: Shipment within 72 hours for standard models; design, production and delivery completed within 15 days for customized projects
- Professional Installation: Service outlets across major cities nationwide, installation and commissioning finished within 7 days to ensure normal system operation
- Operator Training: Professional operation and maintenance training provided for customers to ensure proper equipment use and maintenance
- Acceptance Testing: Sound insulation performance testing conducted post-installation with third-party test reports provided to verify compliance with design standards
13.2.3 After-sales Service
- Warranty Period: 1–3 years free warranty; free replacement of all defective components during warranty coverage
- Fault Response: Dedicated staff responds within 24 hours upon fault notification; on-site troubleshooting completed within 48 hours
- Scheduled Inspection: Two free annual inspections during warranty period to identify and resolve potential hidden faults in advance
- Lifetime Maintenance: Cost-based lifelong maintenance service; timely resolution of any post-warranty failures to eliminate long-term operational worries
- Spare Parts Supply: Long-term stable supply of all spare parts to guarantee timely replacement of damaged components and continuous equipment operation
14. Conclusion
As a professional noise reduction solution, the KITOZER industrial sound insulation enclosure delivers comprehensive noise protection for industrial high-noise equipment via advanced acoustic design, premium material selection and precision manufacturing technology. The system not only effectively cuts equipment operating noise, improves working environments and protects employees’ hearing health, but also helps enterprises meet industrial noise emission standards and avoid environmental fines and rectification orders.
Adhering to the philosophy of Technological Innovation, Quality First, Customer Oriented, we provide full-process solutions including on-site survey, solution design, manufacturing, installation & commissioning and after-sales service. Whether you face noise issues from power equipment such as fans, air compressors and generators, or high-impact equipment including punch presses and crushers, KITOZER can provide optimal noise reduction solutions to enable quiet, safe and efficient factory operation.
Choosing KITOZER industrial sound insulation enclosures means choosing professionalism, quality and reliability. We look forward to cooperating with you to build quiet industrial environments and support sustainable enterprise development.
15. Search Keywords, SEO & Tags
15.1 Core Keywords
Industrial Sound Insulation Enclosure, Industrial Noise Reduction Equipment, KITOZER Sound Insulation Enclosure, Fan Sound Insulation Enclosure, Air Compressor Sound Insulation Enclosure, Generator Sound Insulation Enclosure, Punch Press Sound Insulation Enclosure, Crusher Sound Insulation Enclosure, Industrial Noise Control, Custom Sound Insulation Enclosure
15.2 Long-tail Keywords
Industrial Sound Insulation Enclosure Manufacturer, Industrial Sound Insulation Enclosure Price, Custom Industrial Sound Insulation Enclosure, Industrial Sound Insulation Enclosure Installation, Noise Reduction Effect of Industrial Sound Insulation Enclosure, Explosion-proof Industrial Sound Insulation Enclosure, Anti-corrosion Industrial Sound Insulation Enclosure, High-temperature Industrial Sound Insulation Enclosure, Modular Industrial Sound Insulation Enclosure, Detachable Industrial Sound Insulation Enclosure
15.3 SEO Tags
- Title Tag: KITOZER Industrial Sound Insulation Enclosure | Industrial Noise Reduction Equipment | Professional Noise Control Solutions
- Description Tag: KITOZER industrial sound insulation enclosures deliver professional noise reduction solutions for fans, air compressors, generators and other equipment with 20–45 dB(A) noise reduction. Custom design and installation available to meet industrial noise emission standards.
- Keyword Tag: Industrial Sound Insulation Enclosure, Industrial Noise Reduction Equipment, KITOZER Sound Insulation Enclosure, Fan Sound Insulation Enclosure, Air Compressor Sound Insulation Enclosure, Generator Sound Insulation Enclosure, Industrial Noise Control
15.4 Classification Tags
- Product Category: Industrial Sound Insulation Enclosure, Noise Control Equipment, Environmental Protection Equipment
- Industry Category: Machinery Manufacturing, Power & Energy, Auto Parts, Chemical Industry, Mining, Textile Industry
- Application Category: Fan Noise Reduction, Air Compressor Noise Reduction, Generator Noise Reduction, Punch Press Noise Reduction, Crusher Noise Reduction, Transformer Noise Reduction
- Functional Category: Fully Enclosed Sound Insulation Enclosure, Partial Sound Insulation Enclosure, Movable Sound Insulation Enclosure, Explosion-proof Sound Insulation Enclosure, Anti-corrosion Sound Insulation Enclosure