KITOZER
KITOZER

Special Shielding Protection Device Solution

Shielding Room Construction Drawing

Table of Contents

3. System Classification

Classification is conducted from four dimensions: protection type, structural form, shielding grade and application scenario, to meet targeted protection demands of various scenarios.

3.1 Classification by Protection Type

  • Electromagnetic Shielding Category: Electromagnetic shielding boxes & rooms, blocking electromagnetic interference and information leakage for electromagnetic waves of 150kHz–18GHz.
  • Ionizing Radiation Shielding Category: CT & X-ray shielding rooms, radiation shielding lead plates, blocking ionizing radiation (X-rays, gamma rays) to avoid harm to human bodies.

3.2 Classification by Structural Form

  • Box Type: Electromagnetic shielding boxes, compact modular design, movable or fixed installation, suitable for testing/protection of small-sized equipment.
  • Room Type: CT & X-ray shielding rooms, integral space structure, divided into welded type (high shielding efficiency, fixed non-movable) and assembled type (modular splicing, detachable and relocatable).
  • Plate Type: Radiation shielding lead plates, flexible plate form, customizable for cutting, bending and welding, applicable to special-shaped protection areas such as walls, doors, windows and equipment surfaces.
image

Production Workshop

3.3 Classification by Shielding Grade

  • Basic Grade (Low Configuration): Electromagnetic shielding efficiency ≥40dB (150kHz–1GHz), lead equivalent 1–2mmPb; suitable for low-intensity protection scenarios including general industrial testing and small X-ray rooms.
  • Advanced Grade (Medium Configuration): Electromagnetic shielding efficiency ≥60dB (150kHz–6GHz), lead equivalent 3–5mmPb; suitable for medium-to-high intensity protection scenarios such as medical CT rooms, precision electronic testing and confidential offices.
  • Professional Grade (High Configuration): Electromagnetic shielding efficiency ≥80dB (150kHz–18GHz), lead equivalent 6–20mmPb; suitable for high-intensity/high-confidentiality protection scenarios including military confidential projects, nuclear industry and scientific research accelerators.

3.4 Classification by Application Scenario

  • Medical Scenarios: Shielding protection for CT rooms, X-ray rooms, DR rooms, interventional operating rooms and nuclear medicine departments.
  • Industrial Scenarios: Electromagnetic testing of electronic equipment, industrial flaw detection rooms, high-voltage laboratories, electromagnetic protection for data centers.
  • Scientific Research Scenarios: Accelerator laboratories, isotope laboratories, radiation & electromagnetic protection for precision instrument rooms.
  • Military & Confidential Scenarios: Confidential computer rooms, command centers, electromagnetic shielding and information leakage prevention for military testing laboratories.
image

On-site Installation of Shielding Equipment

4. System Schematic Principles

4.1 Schematic Principle of Electromagnetic Shielding Box

External electromagnetic waves → Cabinet shell (high magnetic permeability / high conductivity metal) → Attenuation via reflection & absorption → Sealing structure (conductive foam / spring strips) to block gap leakage → No electromagnetic interference inside the box

Power supply / signals → Filters → Purify clutter → Internal equipment

Grounding device → Discharge residual electromagnetic energy to the earth

Monitoring module → Real-time detection of shielding efficiency → Alarm for abnormalities

4.2 Schematic Principle of CT & X-ray Shielding Room

X/Gamma rays → Shielding room wall (composite layer of lead plate + steel plate) → Energy absorption & attenuation via photoelectric effect & Compton effect → Shielding door (lead plate + shielding seal) to block leakage at entrances & exits → Shielding observation window (lead glass) to block ray penetration → Indoor radiation dose meets standards

Ventilation → Shielding ventilation waveguide → Block ray/electromagnetic leakage while maintaining indoor air circulation

Power supply → Filters → Eliminate electromagnetic interference to stabilize indoor equipment operation

4.3 Schematic Principle of Radiation Shielding Lead Plate

X/Gamma rays → Lead plate (high-purity lead, density 11.34g/cm³) → High-density atomic layer absorbs ray energy → Overlap lap joints / lead welding block leakage → Base wall / equipment without ray penetration

Anti-oxidation coating on surface → Prevent lead plate oxidation → Long-term stable shielding efficiency

5. Complete System Configuration List (KITOZER Brand, Classified by Low/Medium/High Grades)

5.1 Low-Configuration List (Basic Grade)

表格

No.Product NameModel SpecificationTechnical ParametersQtyUnitBrandRemarks
1Manual Electromagnetic Shielding BoxKITOZER-SB-L011. External dimension: 600×600×800mm2. Material: 1.2mm cold-rolled steel plate with electrostatic spray coating3. Shielding efficiency: ≥40dB (150kHz–1GHz)4. Seal: Conductive foam5. Interfaces: 2 shielded USB ports, 1 shielded network port1SetKITOZERFor basic electromagnetic testing, customizable size
2Simple Assembled CT/X-ray Shielding RoomKITOZER-RS-L011. Internal dimension: 3000×2500×2400mm2. Wall: 1mm steel plate + 1mm lead plate (1mmPb)3. Shielding door: Single manual door, 1mmPb4. Observation window: 200×300mm, 2mm lead glass5. Shielding efficiency: Electromagnetic ≥40dB, ray 1mmPb1SetKITOZERFor small X-ray rooms, modular assembly
3Basic Radiation Shielding Lead PlateKITOZER-PB-L011. Material: No.1 electrolytic lead, purity ≥99.99%2. Spec: 1000×2000×1mm3. Density: 11.34g/cm³4. Lead equivalent: 1mmPb5. Surface: Anti-oxidation coating50SheetKITOZERGeneral radiation protection, cuttable
4Matching Manual Shielding DoorKITOZER-SD-L011. Size: 900×2100mm2. Material: 1.2mm steel plate + 1mm lead plate3. Seal: Conductive spring strips4. Opening mode: Single manual door1UnitKITOZERMatches low-grade shielding room
5Matching Shielding Observation WindowKITOZER-SW-L011. Size: 200×300mm2. Material: 2mm lead glass + metal shielding frame3. Lead equivalent: 2mmPb4. Light transmittance: ≥70%1UnitKITOZERMatches low-grade shielding room
6Basic Power FilterKITOZER-FL-L011. Rated voltage: 220V AC2. Rated current: 10A3. Filter band: 150kHz–30MHz4. Insertion loss: ≥30dB1UnitKITOZERPurify power clutter
7Basic Grounding DeviceKITOZER-GD-L011. Material: Galvanized copper bar2. Spec: 40×4mm3. Ground resistance: ≤4Ω4. Length: 5m1SetKITOZERDischarge residual electromagnetic energy

5.2 Medium-Configuration List (Advanced Grade)

表格

No.Product NameModel SpecificationTechnical ParametersQtyUnitBrandRemarks
1Pneumatic Electromagnetic Shielding BoxKITOZER-SB-M011. External dimension: 800×800×1000mm2. Material: 1.5mm cold-rolled steel plate with electrostatic spray coating3. Shielding efficiency: ≥60dB (150kHz–6GHz)4. Seal: Double-layer conductive spring strips5. Interfaces: 4 USB, 2 network, 1 serial shielded ports6. Opening mode: Automatic pneumatic drive1SetKITOZERPrecision electronic testing, customizable size & interfaces
2Standard Welded-Assembled CT/X-ray Shielding RoomKITOZER-RS-M011. Internal dimension: 4000×3500×2600mm2. Wall: 1.5mm steel plate + 3mm lead plate (3mmPb)3. Shielding door: Double electric door, 3mmPb4. Observation window: 300×400mm, 4mm lead glass5. Shielding efficiency: Electromagnetic ≥60dB, ray 3mmPb6. Ventilation: Shielded ventilation waveguide1SetKITOZERFor medical CT rooms, combination of fixed & detachable structures
3Standard Radiation Shielding Lead PlateKITOZER-PB-M011. Material: No.1 electrolytic lead, purity ≥99.99%2. Spec: 1000×2000×3mm3. Density: 11.34g/cm³4. Lead equivalent: 3mmPb5. Surface: Thickened anti-oxidation & anti-corrosion coating80SheetKITOZERMedical CT / industrial flaw detection protection, bendable
4Matching Electric Shielding DoorKITOZER-SD-M011. Size: 1000×2100mm2. Material: 1.5mm steel plate + 3mm lead plate3. Seal: Triple conductive spring strips + conductive foam4. Opening mode: Double electric door linked with access control1UnitKITOZERMatches medium-grade shielding room with safety induction
5Matching Shielding Observation WindowKITOZER-SW-M011. Size: 300×400mm2. Material: 4mm lead glass + electromagnetic shielding frame3. Lead equivalent: 4mmPb4. Light transmittance: ≥65%5. Shielding efficiency: ≥60dB1UnitKITOZERDual electromagnetic & ray shielding for medium-grade shielding rooms
6Standard Power FilterKITOZER-FL-M011. Rated voltage: 220V/380V AC2. Rated current: 20A3. Filter band: 150kHz–1GHz4. Insertion loss: ≥50dB5. Surge protection1UnitKITOZERPower purification + surge suppression
7Shielded Ventilation WaveguideKITOZER-VT-M011. Size: 300×300mm2. Material: Galvanized steel plate3. Shielding efficiency: ≥60dB (150kHz–6GHz)4. Ventilation volume: ≥500m³/h2UnitKITOZERVentilation while blocking leakage
8Radiation Dose MonitorKITOZER-MO-M011. Measuring range: 0.01–1000μSv/h2. Accuracy: ±10%3. LCD digital display4. Adjustable alarm threshold5. Power supply: 220V AC1SetKITOZERReal-time indoor radiation dose monitoring
9Standard Grounding DeviceKITOZER-GD-M011. Material: Pure copper bar2. Spec: 50×5mm3. Ground resistance: ≤1Ω4. Length: 10m5. Anti-corrosion grounding electrode1SetKITOZERLow-resistance grounding for efficient electromagnetic discharge

5.3 High-Configuration List (Professional Grade)

表格

No.Product NameModel SpecificationTechnical ParametersQtyUnitBrandRemarks
1Full-Automatic Electromagnetic Shielding BoxKITOZER-SB-H011. External dimension: 1000×1000×1200mm2. Material: 2mm stainless steel plate with wire drawing finish3. Shielding efficiency: ≥80dB (150kHz–18GHz)4. Seal: Four-layer high-temperature resistant conductive foam + military-grade conductive spring strips5. Interfaces: 6 USB3.0, 4 network, 2 serial, 1 fiber shielded ports6. Opening mode: Full hydraulic drive with safety interlock1SetKITOZERMilitary/confidential testing, fully customizable
2High-Grade Welded CT/X-ray Shielding RoomKITOZER-RS-H011. Internal dimension: 5000×4500×2800mm2. Wall: 2mm stainless steel + 6mm high-purity lead plate (6mmPb)3. Shielding door: Full-automatic double hydraulic door, 6mmPb with biometric access control4. Observation window: 400×500mm, 8mm lead glass5. Shielding efficiency: Electromagnetic ≥80dB (150kHz–18GHz), ray 6mmPb6. Ventilation: High-efficiency shielding waveguide + constant temperature ventilation7. Grounding: Equipotential grounding system1SetKITOZERNuclear industry / scientific accelerator, highest protection grade
3High-Grade Radiation Shielding Lead PlateKITOZER-PB-H011. Material: Ultra-pure No.1 electrolytic lead, purity ≥99.995%2. Spec: 1000×2000×6mm (customizable 10–20mm)3. Density: 11.34g/cm³4. Lead equivalent: 6mmPb (customizable 10–20mmPb)5. Surface: Nano anti-oxidation & acid-alkali resistant coating6. Thickness tolerance: ≤±0.05mm120SheetKITOZERNuclear industry / high-intensity radiation protection, high precision
4Matching Full-Automatic Shielding DoorKITOZER-SD-H011. Size: 1200×2100mm2. Material: 2mm stainless steel + 6mm lead plate3. Seal: Five-layer military conductive spring strips + high-temperature conductive foam4. Opening mode: Full hydraulic double door with fingerprint + face dual recognition5. Shielding efficiency: ≥80dB1UnitKITOZERConfidential-grade safety for high-grade shielding rooms
5Matching Shielding Observation WindowKITOZER-SW-H011. Size: 400×500mm2. Material: 8mm lead glass + military-grade shielding frame3. Lead equivalent: 8mmPb4. Light transmittance: ≥60%5. Shielding efficiency: ≥80dB6. Anti-glare coating1UnitKITOZERMilitary-grade dual shielding for high-grade shielding rooms
6High-Grade Power FilterKITOZER-FL-H011. Rated voltage: 380V AC2. Rated current: 30A3. Filter band: 150kHz–18GHz4. Insertion loss: ≥70dB5. Dual EMI/EMC filtering + lightning protection1UnitKITOZERMilitary-grade full-band power purification
7Signal FilterKITOZER-SF-H011. Compatible interfaces: Network / serial / fiber2. Filter band: 150kHz–18GHz3. Insertion loss: ≥70dB4. Impedance matching: 50Ω / 75Ω4UnitKITOZERElectromagnetic shielding for signal lines to prevent information leakage
8High-Efficiency Shielded Ventilation WaveguideKITOZER-VT-H011. Size: 400×400mm2. Material: 304 stainless steel3. Shielding efficiency: ≥80dB (150kHz–18GHz)4. Ventilation volume: ≥800m³/h5. Dust filter screen2UnitKITOZERConstant temperature ventilation + military shielding
9Multi-Functional Monitoring TerminalKITOZER-MO-H011. Monitors: Radiation dose, shielding efficiency, temperature & humidity, access status2. Display: 10-inch touch screen3. Alarm: Acoustic-optical + remote SMS alert4. Communication: 4G + Ethernet remote monitoring5. Backup battery endurance ≥8h1SetKITOZERIntegrated full-system monitoring with remote control
10Equipotential Grounding SystemKITOZER-GD-H011. Material: Pure copper strip & copper bar2. Spec: Copper strip 50×0.5mm, copper bar 60×6mm3. Ground resistance: ≤0.5Ω4. Equipotential connection for all walls, doors and windows5. Lightning protection grounding electrode1SetKITOZERMilitary-grade grounding to eliminate potential difference interference

6. Full Product Technical Parameters

6.1 Electromagnetic Shielding Box Series

image

Exploded Drawing of Shielding Box Structure

6.1.1 Manual Electromagnetic Shielding Box (KITOZER-SB-L01)

  • External dimension: 600×600×800mm (customizable)
  • Internal dimension: 500×500×700mm
  • Cabinet material: 1.2mm cold-rolled steel plate with electrostatic spray coating (gray/white optional)
  • Shielding efficiency: ≥40dB (150kHz–1GHz)
  • Sealing structure: High-elastic conductive foam for cabinet seams, single-circle conductive spring strips for door
  • Interfaces: 2 shielded USB ports, 1 RJ45 shielded network port, 1 power port
  • Opening mode: Manual flip / side opening with special lock
  • Weight: ~80kg
  • Operating temperature: -10℃ ~ 50℃
  • Protection grade: IP54

6.1.2 Pneumatic Electromagnetic Shielding Box (KITOZER-SB-M01)

  • External dimension: 800×800×1000mm (customizable)
  • Internal dimension: 700×700×900mm
  • Cabinet material: 1.5mm cold-rolled steel plate with electrostatic spray coating
  • Shielding efficiency: ≥60dB (150kHz–6GHz)
  • Sealing structure: Double-layer conductive foam for cabinet seams, double conductive spring strips for door with four-corner reinforced sealing
  • Interfaces: 4 shielded USB ports, 2 RJ45 shielded network ports, 1 RS232 shielded serial port, 1 power port
  • Opening mode: Automatic pneumatic side opening with anti-pinch safety induction
  • Driving air pressure: 0.4–0.6MPa
  • Weight: ~150kg
  • Operating temperature: -10℃ ~ 50℃
  • Protection grade: IP55

6.1.3 Full-Automatic Electromagnetic Shielding Box (KITOZER-SB-H01)

image

CT Room Installation Site

  • External dimension: 1000×1000×1200mm (customizable)
  • Internal dimension: 900×900×1100mm
  • Cabinet material: 2mm 304 stainless steel plate with wire drawing anti-corrosion finish
  • Shielding efficiency: ≥80dB (150kHz–18GHz), complies with GJB 5792-2021 Grade D standard
  • Sealing structure: Four-layer high-temperature resistant conductive foam for cabinet seams, four-layer military-grade conductive spring strips for full-perimeter seamless door sealing
  • Interfaces: 6 shielded USB3.0 ports, 4 RJ45 shielded network ports, 2 RS485 shielded serial ports, 1 fiber shielded port, 1 high-power power port
  • Opening mode: Full hydraulic side opening, fingerprint + face dual safety interlock, emergency manual opening in power failure
  • Driving voltage: 220V AC, hydraulic system pressure: 5–8MPa
  • Weight: ~280kg
  • Operating temperature: -20℃ ~ 60℃
  • Protection grade: IP65
  • Additional functions: Built-in temperature & humidity sensor, smoke alarm, remote control support

6.2 CT & X-ray Shielding Room Series

6.2.1 Simple CT/X-ray Shielding Room (KITOZER-RS-L01)

image

Simple Shielding Room Interior Effect

  • Internal dimension: 3000×2500×2400mm (L×W×H, customizable)
  • Wall structure: Outer 1mm cold-rolled steel plate + inner 1mm lead plate (1mmPb), keel support, modular splicing
  • Ceiling/Floor: Ceiling with 1mm steel plate + 1mm lead plate; floor with 1mm lead plate + anti-slip floor leather
  • Shielding door: Single manual door, 900×2100mm, 1.2mm steel plate + 1mm lead plate, conductive spring strip sealing
  • Observation window: 200×300mm, 2mm lead glass, metal shielding frame, lead equivalent 2mmPb
  • Shielding efficiency: Electromagnetic ≥40dB (150kHz–1GHz), ray 1mmPb (blocks over 90% low-energy X-rays)
  • Ventilation: Natural ventilation + simple shielding vent
  • Grounding: Basic grounding device, ground resistance ≤4Ω
  • Applicable ray energy: ≤100keV (small X-ray machine)
  • Weight: ~1200kg
  • Installation cycle: 3–5 days

6.2.2 Standard CT/X-ray Shielding Room (KITOZER-RS-M01)

image

Shielded Command Center

  • Internal dimension: 4000×3500×2600mm (L×W×H, customizable)
  • Wall structure: Outer 1.5mm cold-rolled steel plate + inner 3mm lead plate (3mmPb), bottom welding + upper modular splicing, double-layer reinforced keel
  • Ceiling/Floor: Ceiling with 1.5mm steel plate + 3mm lead plate; floor with 3mm lead plate + anti-static floor, lead welding sealed joints
  • Shielding door: Double electric door, 1000×2100mm, 1.5mm steel plate + 3mm lead plate, triple conductive spring strips + conductive foam sealing, access control linkage
  • Observation window: 300×400mm, 4mm lead glass, electromagnetic shielding frame, lead equivalent 4mmPb, electromagnetic shielding ≥60dB
  • Shielding efficiency: Electromagnetic ≥60dB (150kHz–6GHz), ray 3mmPb (blocks over 95% X-rays below 150keV)
  • Ventilation: 2 sets KITOZER-VT-M01 shielding ventilation waveguides, total ventilation ≥1000m³/h
  • Grounding: Standard grounding device, ground resistance ≤1Ω with equipotential connection
  • Applicable ray energy: ≤150keV (medical CT/DR machine)
  • Weight: ~2500kg
  • Installation cycle: 7–10 days

6.2.3 High-Grade CT/X-ray Shielding Room (KITOZER-RS-H01)

image

High-Grade Welded Shielding Room Exterior

  • Internal dimension: 5000×4500×2800mm (L×W×H, customizable)
  • Wall structure: Outer 2mm 304 stainless steel plate + inner 6mm high-purity lead plate (6mmPb), full welding seamless sealing, military-grade reinforced keel
  • Ceiling/Floor: Ceiling with 2mm stainless steel + 6mm lead plate; floor with 6mm lead plate + wear-resistant anti-static floor, full lead-welded joints with anti-corrosion treatment
  • Shielding door: Full hydraulic double automatic door, 1200×2100mm, 2mm stainless steel + 6mm lead plate, five-layer military conductive spring strips + high-temperature conductive foam, fingerprint + face dual recognition access control, emergency manual opening in power failure
  • Observation window: 400×500mm, 8mm high-transmittance lead glass, military-grade shielding frame, lead equivalent 8mmPb, electromagnetic shielding ≥80dB, anti-glare coating
  • Shielding efficiency: Electromagnetic ≥80dB (150kHz–18GHz), complies with GJB 5792-2021 Grade C standard; ray 6mmPb (blocks over 99% X-rays & gamma rays below 200keV)
  • Ventilation: 2 sets KITOZER-VT-H01 high-efficiency shielding waveguides + constant temperature ventilation system, temperature control 22±2℃, total ventilation ≥1600m³/h
  • Grounding: Equipotential grounding system, ground resistance ≤0.5Ω, equipotential connection for all metal components with lightning protection
  • Applicable ray energy: ≤200keV (nuclear industry / scientific accelerators / high-intensity CT)
  • Weight: ~4500kg
  • Installation cycle: 15–20 days
  • Additional functions: Built-in multi-functional monitoring terminal, emergency lighting, acoustic-optical alarm, remote monitoring & fault early warning support

6.3 Radiation Shielding Lead Plate Series

image

Indoor Engineering Case of Shielding Equipment

6.3.1 Basic Radiation Shielding Lead Plate (KITOZER-PB-L01)

  • Material: No.1 electrolytic pure lead, purity ≥99.99%, impurity-free
  • Spec: 1000×2000×1mm (W×L×T, customizable)
  • Density: 11.34g/cm³ (20℃)
  • Lead equivalent: 1mmPb (corresponds to 1mm pure lead thickness)
  • Surface treatment: Single-sided gray anti-oxidation coating, moisture & corrosion resistant
  • Thickness tolerance: ±0.1mm
  • Flatness: ≤2mm/m
  • Tensile strength: ≥15MPa
  • Applicable rays: Low-energy X-rays ≤80keV
  • Weight: ~22.68kg per sheet

6.3.2 Standard Radiation Shielding Lead Plate (KITOZER-PB-M01)

  • Material: No.1 electrolytic pure lead, purity ≥99.99%, dense pore-free
  • Spec: 1000×2000×3mm (W×L×T, customizable size/thickness)
  • Density: 11.34g/cm³ (20℃)
  • Lead equivalent: 3mmPb (corresponds to 3mm pure lead thickness)
  • Surface treatment: Double-sided thickened anti-oxidation & acid-alkali resistant coating, compatible with medical disinfectants
  • Thickness tolerance: ±0.08mm
  • Flatness: ≤1.5mm/m
  • Tensile strength: ≥18MPa
  • Bendability: 90° bending without cracks
  • Applicable rays: Medical X-rays / CT rays ≤150keV
  • Weight: ~68.04kg per sheet

6.3.3 High-Grade Radiation Shielding Lead Plate (KITOZER-PB-H01)

  • Material: Ultra-pure No.1 electrolytic lead, purity ≥99.995%, vacuum smelted, no impurities or pores
  • Spec: 1000×2000×6mm (W×L×T, customizable 10–20mm thickness)
  • Density: 11.34g/cm³ (20℃)
  • Lead equivalent: 6mmPb (customizable 10–20mmPb)
  • Surface treatment: Double-sided nano anti-oxidation & acid-alkali resistant coating, no oxidation under long-term exposure
  • Thickness tolerance: ±0.05mm (high precision)
  • Flatness: ≤1mm/m
  • Tensile strength: ≥20MPa
  • Bendability: Arbitrary-angle bending & welding without cracks, excellent sealing performance
  • Applicable rays: High-intensity X-rays / gamma rays ≤200keV (nuclear industry / scientific research)
  • Weight: ~136.08kg per sheet

6.4 Technical Parameters of Supporting Products

6.4.1 Shielding Door Series

  • KITOZER-SD-L01 (Manual): Size 900×2100mm, 1.2mm steel + 1mm lead plate, lead equivalent 1mmPb, single-circle conductive spring strip sealing, single manual opening, weight ~80kg
  • KITOZER-SD-M01 (Electric): Size 1000×2100mm, 1.5mm steel + 3mm lead plate, lead equivalent 3mmPb, triple conductive spring strips + conductive foam, double electric opening with safety induction, weight ~150kg
  • KITOZER-SD-H01 (Full-Automatic): Size 1200×2100mm, 2mm stainless steel + 6mm lead plate, lead equivalent 6mmPb, five-layer military conductive spring strips, full hydraulic double automatic opening with biometric access control, weight ~280kg

6.4.2 Shielding Observation Window Series

  • KITOZER-SW-L01: Size 200×300mm, 2mm lead glass, lead equivalent 2mmPb, light transmittance ≥70%, electromagnetic shielding ≥40dB, metal frame
  • KITOZER-SW-M01: Size 300×400mm, 4mm lead glass, lead equivalent 4mmPb, light transmittance ≥65%, electromagnetic shielding ≥60dB, electromagnetic shielding frame
  • KITOZER-SW-H01: Size 400×500mm, 8mm lead glass, lead equivalent 8mmPb, light transmittance ≥60%, electromagnetic shielding ≥80dB, military shielding frame with anti-glare coating

6.4.3 Filter Series

  • KITOZER-FL-L01 (Power): 220V AC, 10A, 150kHz–30MHz, insertion loss ≥30dB, single-stage filtering
  • KITOZER-FL-M01 (Power): 220V/380V AC, 20A, 150kHz–1GHz, insertion loss ≥50dB, dual-stage filtering + surge protection
  • KITOZER-FL-H01 (Power): 380V AC, 30A, 150kHz–18GHz, insertion loss ≥70dB, three-stage filtering + lightning protection
  • KITOZER-SF-H01 (Signal): Compatible with network/serial/fiber ports, 150kHz–18GHz, insertion loss ≥70dB, impedance matching 50Ω/75Ω

6.4.4 Shielded Ventilation Waveguide Series

  • KITOZER-VT-M01: 300×300mm, galvanized steel plate, shielding efficiency ≥60dB (150kHz–6GHz), ventilation ≥500m³/h
  • KITOZER-VT-H01: 400×400mm, 304 stainless steel, shielding efficiency ≥80dB (150kHz–18GHz), ventilation ≥800m³/h with dust filter screen

6.4.5 Monitoring Instrument Series

  • KITOZER-MO-M01 (Radiation Dose Meter): Measuring range 0.01–1000μSv/h, accuracy ±10%, LCD display, adjustable alarm threshold, 220V AC power supply
  • KITOZER-MO-H01 (Multi-Functional Terminal): Monitors radiation dose, shielding efficiency, temperature & humidity, access status; 10-inch touch screen, acoustic-optical + remote alarm, 4G+Ethernet communication, backup battery endurance ≥8h

7. Full Product Application Scope

7.1 Application Scope of Electromagnetic Shielding Boxes

  1. Electronic Testing: RF testing of wireless devices (Bluetooth, WiFi); EMI testing of PCBs; anti-interference testing of sensors & precision instruments; shielding testing of 5G/6G communication equipment.
  2. Confidential Information: Information leakage prevention for confidential laptops & mobile storage devices; electromagnetic shielding for small confidential equipment; temporary shielding for small conference rooms & offices.
  3. Industrial Control: Anti-electromagnetic interference protection for industrial PLCs & inverters; electromagnetic isolation of automation equipment; shielding for precision processing machinery.
  4. Scientific Research: Electromagnetic shielding for small laboratory instruments; anti-interference detection of weak signals; electromagnetic isolation of biomedical equipment.

7.2 Application Scope of CT & X-ray Shielding Rooms

  1. Medical Industry: Hospital CT, X-ray, DR, CR rooms; interventional catheter laboratories; nuclear medicine (PET-CT, isotope therapy); dental CT & panoramic machine rooms; X-ray rooms for pet hospitals.
  2. Industrial Industry: Industrial flaw detection rooms (weld, casting, pipeline ray inspection); non-destructive testing laboratories; high-voltage & electrostatic protection rooms; electromagnetic shielding computer rooms for data centers.
  3. Scientific Research: Accelerator & isotope laboratories of universities & research institutes; precision instrument rooms (electron microscopes, mass spectrometers); electromagnetic shielding rooms for astronomical observation equipment.
  4. Military & Confidential: Confidential testing laboratories of military enterprises; command centers & communication shielding rooms; testing rooms for radar & electronic countermeasure equipment; confidential information processing centers.

7.3 Application Scope of Radiation Shielding Lead Plates

  1. Medical Protection: Wall, floor & ceiling shielding for CT/X-ray rooms; lining for shielding doors & observation windows; mobile protective screens for interventional surgeries; shielding cabinets & operating tables in nuclear medicine departments; radiation isolation for hospital corridors & elevators.
  2. Industrial Flaw Detection: Wall, door & window shielding for flaw detection rooms; protective barriers around flaw detectors; inner lining for radiation source storage & transportation containers; protective layers around nuclear reactor facilities.
  3. Scientific Research: Radiation partition for accelerators & synchrotron radiation devices; shielding for laboratory ray equipment; inner lining for radioactive sample storage cabinets & operating tables.
  4. Special Scenarios: Shielding for security inspection equipment (airports, stations); protection during dismantling of waste ray equipment; emergency shielding for radiation environments; anti-corrosion lining, ship counterweight & sound insulation projects.

7.4 Application Scope of Supporting Products

  1. Shielding Doors & Observation Windows: Matching entrances & observation ports of all shielding rooms; medical ray protection doors & windows; electromagnetic shielding doors & windows for confidential computer rooms.
  2. Filters: Electromagnetic purification for power & signal lines of shielding rooms & precision equipment; power filtering for medical devices; EMI/EMC protection for military equipment.
  3. Shielded Ventilation Waveguides: Heat dissipation & electromagnetic/ray shielding for shielding rooms; ventilation systems of confidential computer rooms; ventilation shielding for industrial testing laboratories.
  4. Monitoring Instruments: Real-time monitoring of radiation dose & shielding efficiency in shielding rooms; safety monitoring of medical ray environments; electromagnetic environment monitoring for confidential computer rooms.

8. Full Product Advantages

8.1 Advantages of Electromagnetic Shielding Box Series

8.1.1 Core Functional Features

  1. High-efficiency shielding: Basic grade ≥40dB, medium grade ≥60dB, high grade ≥80dB, full coverage of 150kHz–18GHz to block electromagnetic interference & information leakage.
  2. Precision sealing: Double-layer conductive foam + spring strip sealing; high-grade with four-layer military sealing, gap leakage rate ≤0.01% for stable shielding efficiency.
  3. Premium materials: Low/medium grades with electrostatic sprayed cold-rolled steel (corrosion & scratch resistant); high grade with 304 stainless steel wire drawing (military durability, service life ≥15 years).
  4. Flexible adaptation: Customizable size, interface quantity & type; manual/pneumatic/full-automatic opening options to fit different equipment sizes & operation demands.
  5. Safe & reliable: High-grade equipped with safety interlock & emergency opening to prevent pinching & power failure faults; built-in temperature & humidity monitoring with overheat protection.

8.1.2 Customization & Service Advantages

  1. Full customization: Non-standard size, special interfaces (fiber, high-frequency) & special functions (built-in power supply, temperature control) available for design & OEM production.
  2. Confidential production: Confidential-grade production process with non-disclosure agreements to eliminate technical & product information leakage.
  3. Spot supply: Standard low/medium grades in stock, delivery within 72 hours; high-grade customization cycle 7–15 days for fast delivery.
  4. Superior technical parameters: Core indicators (shielding efficiency, interface configuration, sealing technology) exceed industry standards; high grade meets military GJB standards with stable performance.

8.2 Advantages of CT & X-ray Shielding Room Series

8.2.1 Core Functional Features

  1. Dual integrated protection: Simultaneous electromagnetic & ionizing radiation shielding; 1mmPb for basic grade, 3mmPb for medium grade, 6mmPb for high grade.
  2. Premium materials: Composite wall of steel + high-purity lead plate (purity ≥99.99%); high-grade stainless steel outer layer for anti-corrosion, lead plate thickness tolerance ≤±0.05mm for precise protection.
  3. Advanced craftsmanship: Basic grade modular splicing for fast install & relocation; medium grade welding + assembly for stability & flexibility; high grade full military welding for seamless long-term shielding efficiency.
  4. Intelligent safety: High-grade with biometric access control, remote monitoring, acoustic-optical alarm & emergency lighting; real-time radiation dose & shielding efficiency monitoring with automatic abnormal alerts.
  5. Environmental adaptability: High-grade constant temperature ventilation system (22±2℃), large air volume for indoor circulation & stable equipment operation; anti-static floor for precision equipment environments.

8.2.2 Customization & Service Advantages

  1. Personalized customization: Custom size, lead equivalent & layout (single/double room, with/without observation window) for hospitals, industry & research institutes; one-stop design-production-installation service.
  2. Confidential construction: Non-disclosure agreements for confidential projects with full confidential construction; military construction standards with strict quality control.
  3. Fast delivery: Standard low/medium grade components in stock, installation cycle 3–10 days; high-grade customization cycle 15–20 days for efficient delivery.
  4. Superior technical parameters: Shielding efficiency, lead equivalent & ground resistance exceed national standards; high grade complies with GJB 5792-2021 Grade C, radiation leakage rate below 0.001mSv/h for full safety.

8.3 Advantages of Radiation Shielding Lead Plate Series

8.3.1 Core Functional Features

  1. Extreme shielding efficiency: High-purity lead (≥99.99%), density 11.34g/cm³, atomic number 82 with ultra-high absorption rate for X & gamma rays; 1mm lead plate equals 30cm concrete shielding equivalent for high space utilization.
  2. Easy processing & adaptation: Soft & ductile, freely cut, bent, punched & welded to fit curved walls & equipment contours; flexible multi-layer stacking for adjustable protection equivalent.
  3. Durable & stable: Stable chemical properties, moisture & corrosion resistant with anti-oxidation coating; no deformation or oxidation over service life ≥20 years with near-zero maintenance cost.
  4. Safe & eco-friendly: Complies with GBZ 130-2020 medical protection standards, non-radioactive & non-toxic under standardized use; recyclable for environmental protection.
  5. Complete specifications: Standard thickness 1–20mm & size 1000×2000mm, customizable non-standard dimensions/thicknesses for all protection scenarios.

8.3.2 Customization & Service Advantages

  1. In-depth customization: Custom thickness (1–20mm), size & shape (arc, special-shaped) for walls, doors, windows & equipment surfaces; OEM cutting, bending & welding for finished shielding components.
  2. Confidential supply: Full confidential supply for confidential/special projects with non-disclosure agreements to prevent product flow information leakage.
  3. Sufficient spot inventory: Standard 1–6mm lead plates in stock, next-day delivery upon order; 10–20mm thick plates customized within 3–7 days for fast delivery.
  4. Superior technical parameters: Industry-leading lead purity ≥99.99%, thickness tolerance ≤±0.05mm, flatness ≤1mm/m for precise stable shielding & ultra-low radiation leakage.

8.4 Advantages of Supporting Products

  1. Complete supporting series: One-stop procurement of shielding doors, observation windows, filters, ventilation waveguides & monitoring instruments with high compatibility without extra adaptation.
  2. Military-grade quality: Core high-grade supporting products adopt military materials & craftsmanship with reliable shielding efficiency & durability.
  3. Customized adaptation: Customizable size, parameters & functions to match all shielding boxes & rooms for integrated easy installation.
  4. Spot supply: Standard supporting products in stock for fast delivery; short customization cycles for tailor-made products.

9. Bid Evaluation Core Parameters (Marked with ★)

9.1 Electromagnetic Shielding Box Bid Parameters

9.1.1 Manual Electromagnetic Shielding Box (KITOZER-SB-L01)

★1. Shielding efficiency: ≥40dB (150kHz–1GHz)

★2. Cabinet material: ≥1.2mm cold-rolled steel plate with electrostatic spray coating

★3. Sealing structure: Conductive foam + single-circle conductive spring strips

★4. Interfaces: ≥2 shielded USB ports, 1 RJ45 shielded network port

★5. Protection grade: ≥IP54

9.1.2 Pneumatic Electromagnetic Shielding Box (KITOZER-SB-M01)

★1. Shielding efficiency: ≥60dB (150kHz–6GHz)

★2. Cabinet material: ≥1.5mm cold-rolled steel plate with electrostatic spray coating

★3. Sealing structure: Double conductive foam + double conductive spring strips

★4. Interfaces: ≥4 shielded USB ports, 2 RJ45 shielded network ports, 1 RS232 serial port

★5. Opening mode: Automatic pneumatic drive with safety induction device

★6. Protection grade: ≥IP55

9.1.3 Full-Automatic Electromagnetic Shielding Box (KITOZER-SB-H01)

★1. Shielding efficiency: ≥80dB (150kHz–18GHz), complies with GJB 5792-2021 Grade D standard

★2. Cabinet material: ≥2mm 304 stainless steel plate with wire drawing finish

★3. Sealing structure: Four-layer high-temperature conductive foam + four-layer military conductive spring strips

★4. Interfaces: ≥6 shielded USB3.0 ports, 4 RJ45 shielded network ports, 2 RS485 serial ports, 1 fiber port

★5. Opening mode: Full hydraulic drive with fingerprint + face dual safety interlock

★6. Protection grade: ≥IP65

★7. Additional functions: Built-in temperature & humidity sensor, smoke alarm, remote control support

9.2 CT & X-ray Shielding Room Bid Parameters

9.2.1 Simple CT/X-ray Shielding Room (KITOZER-RS-L01)

★1. Internal dimension: ≥3000×2500×2400mm (L×W×H)

★2. Wall structure: ≥1mm steel plate + ≥1mm lead plate (1mmPb)

★3. Shielding door: Single manual door, ≥1mmPb

★4. Observation window: ≥200×300mm, ≥2mm lead glass, 2mmPb

★5. Shielding efficiency: Electromagnetic ≥40dB (150kHz–1GHz), ray ≥1mmPb

★6. Applicable ray energy: ≤100keV

9.2.2 Standard CT/X-ray Shielding Room (KITOZER-RS-M01)

★1. Internal dimension: ≥4000×3500×2600mm (L×W×H)

★2. Wall structure: ≥1.5mm steel plate + ≥3mm lead plate (3mmPb)

★3. Shielding door: Double electric door, ≥3mmPb with access control linkage

★4. Observation window: ≥300×400mm, ≥4mm lead glass, 4mmPb, electromagnetic shielding ≥60dB

★5. Shielding efficiency: Electromagnetic ≥60dB (150kHz–6GHz), ray ≥3mmPb

★6. Ventilation: ≥2 shielding ventilation waveguides, single ventilation ≥500m³/h

★7. Ground resistance: ≤1Ω

★8. Applicable ray energy: ≤150keV

9.2.3 High-Grade CT/X-ray Shielding Room (KITOZER-RS-H01)

★1. Internal dimension: ≥5000×4500×2800mm (L×W×H)

★2. Wall structure: ≥2mm 304 stainless steel plate + ≥6mm high-purity lead plate (6mmPb), full welding process

★3. Shielding door: Full hydraulic double automatic door, ≥6mmPb with fingerprint + face dual recognition access control

★4. Observation window: ≥400×500mm, ≥8mm lead glass, 8mmPb, electromagnetic shielding ≥80dB with anti-glare coating

★5. Shielding efficiency: Electromagnetic ≥80dB (150kHz–18GHz) complies with GJB 5792-2021 Grade C; ray ≥6mmPb

★6. Ventilation: ≥2 high-efficiency shielding waveguides + constant temperature ventilation system, temperature control 22±2℃

★7. Ground resistance: ≤0.5Ω with equipotential grounding system

★8. Applicable ray energy: ≤200keV

★9. Monitoring function: Equipped with multi-functional terminal for real-time monitoring of radiation dose, shielding efficiency & temperature & humidity

9.3 Radiation Shielding Lead Plate Bid Parameters

9.3.1 Basic Radiation Shielding Lead Plate (KITOZER-PB-L01)

★1. Lead purity: ≥99.99% (No.1 electrolytic pure lead)

★2. Spec: ≥1000×2000×1mm

★3. Density: 11.34g/cm³ (20℃)

★4. Lead equivalent: ≥1mmPb

★5. Thickness tolerance: ≤±0.1mm

★6. Flatness: ≤2mm/m

9.3.2 Standard Radiation Shielding Lead Plate (KITOZER-PB-M01)

★1. Lead purity: ≥99.99% (No.1 electrolytic pure lead)

★2. Spec: ≥1000×2000×3mm

★3. Density: 11.34g/cm³ (20℃)

★4. Lead equivalent: ≥3mmPb

★5. Thickness tolerance: ≤±0.08mm

★6. Flatness: ≤1.5mm/m

★7. Bendability: 90° bending without cracks

9.3.3 High-Grade Radiation Shielding Lead Plate (KITOZER-PB-H01)

★1. Lead purity: ≥99.995% (ultra-pure vacuum smelted No.1 electrolytic lead)

★2. Spec: ≥1000×2000×6mm

★3. Density: 11.34g/cm³ (20℃)

★4. Lead equivalent: ≥6mmPb

★5. Thickness tolerance: ≤±0.05mm (high precision)

★6. Flatness: ≤1mm/m

★7. Bendability: Arbitrary-angle bending & welding without cracks

★8. Surface treatment: Double-sided nano anti-oxidation & acid-alkali resistant coating

9.4 Core Bid Parameters of Supporting Products

9.4.1 Shielding Door

★1. Lead equivalent: Matched to corresponding shielding room (1mmPb basic / 3mmPb medium / 6mmPb high)

★2. Shielding efficiency: Matched to corresponding shielding room (≥40dB basic / ≥60dB medium / ≥80dB high)

★3. Sealing structure: Single-circle basic / triple medium / five-layer military spring strips + conductive foam high grade

9.4.2 Shielding Observation Window

★1. Lead equivalent: Matched to corresponding shielding room (2mmPb basic / 4mmPb medium / 8mmPb high)

★2. Shielding efficiency: Matched to corresponding shielding room (≥40dB basic / ≥60dB medium / ≥80dB high)

★3. Light transmittance: ≥70% basic / ≥65% medium / ≥60% high

9.4.3 Filter

★1. Insertion loss: ≥30dB basic / ≥50dB medium / ≥70dB high

★2. Filter band: 150kHz–30MHz basic / 150kHz–1GHz medium / 150kHz–18GHz high

9.4.4 Shielded Ventilation Waveguide

★1. Shielding efficiency: ≥60dB medium / ≥80dB high

★2. Ventilation volume: ≥500m³/h medium / ≥800m³/h high

10. Full Product Solution Packages

10.1 Electromagnetic Shielding Box Solutions

10.1.1 Small Electronic Testing Solution (Basic Grade)

  • Applicable Scenarios: RF testing of small wireless devices (Bluetooth, WiFi), PCB EMI testing, anti-interference testing of ordinary sensors.
  • Configuration Combination: KITOZER-SB-L01 manual shielding box + KITOZER-FL-L01 basic power filter + KITOZER-GD-L01 basic grounding device.
  • Solution Advantages: Low cost, compact & movable, easy installation; meets basic electromagnetic testing demands; standard models in stock for fast deployment.
  • Implementation Steps:
    1. Place & level the shielding box in test area;
    2. Connect power filter & grounding device;
    3. Link test equipment & instruments, close box door;
    4. Start testing with real-time shielding efficiency monitoring.

10.1.2 Precision Electronic Testing Solution (Medium Grade)

  • Applicable Scenarios: 5G/6G communication equipment testing, anti-interference testing of precision instruments (oscilloscopes, signal generators), electromagnetic isolation of industrial PLCs.
  • Configuration Combination: KITOZER-SB-M01 pneumatic shielding box + KITOZER-FL-M01 standard power filter + KITOZER-GD-M01 standard grounding device.
  • Solution Advantages: High shielding efficiency ≥60dB, automatic pneumatic operation, superior sealing for precision testing; customizable interfaces with strong compatibility.
  • Implementation Steps:
    1. Fix shielding box & connect air source (0.4–0.6MPa);
    2. Install power filter & standard grounding device (ground resistance ≤1Ω);
    3. Connect test equipment via shielded interfaces & start pneumatic system;
    4. Close box door, launch testing & monitor shielding efficiency & equipment status.

10.1.3 Military/Confidential Testing Solution (High Grade)

  • Applicable Scenarios: Military confidential equipment testing, information leakage prevention for confidential laptops, shielding testing of satellite communication equipment, electromagnetic protection for high-security laboratories.
  • Configuration Combination: KITOZER-SB-H01 full-automatic shielding box + KITOZER-FL-H01 high-grade power filter + KITOZER-SF-H01 signal filter + KITOZER-GD-H01 equipotential grounding system + KITOZER-MO-H01 multi-functional monitoring terminal.
  • Solution Advantages: Military-grade shielding efficiency ≥80dB, safe full hydraulic automatic operation, full-band filtering to prevent information leakage, intelligent remote monitoring; complies with GJB 5792-2021 confidential standards with full confidential production & delivery.
  • Implementation Steps:
    1. Fix shielding box & connect hydraulic system & 220V power supply;
    2. Install power/signal filters & equipotential grounding system (ground resistance ≤0.5Ω);
    3. Link confidential equipment via shielded interfaces & activate biometric access control;
    4. Close box door, launch multi-functional terminal to monitor shielding efficiency, temperature & humidity & access status in real time;
    5. Authorize remote terminal operation for testing with full encrypted data recording.

10.2 CT & X-ray Shielding Room Solutions

10.2.1 X-ray Room Solution for Small Hospitals/Clinics (Basic Grade)

  • Applicable Scenarios: X-ray rooms of township hospitals, community clinics & pet hospitals (≤100keV), basic ray protection + simple electromagnetic shielding.
  • Configuration Combination: KITOZER-RS-L01 simple shielding room + KITOZER-SD-L01 manual shielding door + KITOZER-SW-L01 shielding observation window + KITOZER-FL-L01 basic power filter + KITOZER-GD-L01 basic grounding device.
  • Solution Advantages: Low cost, modular splicing for fast 3–5 day install & relocation; meets basic ray protection with 1mmPb to block low-energy X-rays & protect medical staff & surrounding personnel.
  • Implementation Steps:
    1. On-site measurement & ground leveling;
    2. Assemble shielding room keel & wall (steel + lead plate), lay ceiling & floor;
    3. Install manual shielding door & observation window, seal all seams;
    4. Connect power filter & basic grounding device;
    5. Accept shielding efficiency & ray protection before commissioning.

10.2.2 CT/DR Room Solution for General Hospitals (Medium Grade)

  • Applicable Scenarios: CT & DR rooms of county/municipal general hospitals (≤150keV), routine medical ray protection + electromagnetic interference isolation.
  • Configuration Combination: KITOZER-RS-M01 standard shielding room + KITOZER-SD-M01 electric shielding door + KITOZER-SW-M01 shielding observation window + KITOZER-FL-M01 standard power filter + KITOZER-VT-M01 shielding ventilation waveguide + KITOZER-MO-M01 radiation dose monitor + KITOZER-GD-M01 standard grounding device.
  • Solution Advantages: 3mmPb blocks over 95% X-rays below 150keV, electromagnetic shielding ≥60dB, convenient electric door operation, good ventilation & real-time radiation monitoring; ensures stable medical equipment operation & staff safety, 7–10 day installation balancing stability & flexibility.
  • Implementation Steps:
    1. On-site survey & construction drawing design;
    2. Weld bottom wall, assemble upper modules, lay floor lead plate & anti-static floor with lead-welded sealed joints;
    3. Install electric shielding door & electromagnetic shielding observation window with triple sealing;
    4. Mount shielding ventilation waveguides & power filter, connect standard grounding device (ground resistance ≤1Ω);
    5. Install radiation dose monitor & debug access control linkage;
    6. Accept shielding efficiency, ray leakage rate & ground resistance before delivery.

10.2.3 Nuclear Industry/Scientific Accelerator Shielding Room Solution (High Grade)

  • Applicable Scenarios: Accelerator laboratories of nuclear enterprises & university research institutes, high-intensity CT rooms (≤200keV), high-strength ray protection + military electromagnetic shielding + intelligent monitoring.
  • Configuration Combination: KITOZER-RS-H01 high-grade shielding room + KITOZER-SD-H01 full-automatic shielding door + KITOZER-SW-H01 shielding observation window + KITOZER-FL-H01 high-grade power filter + KITOZER-SF-H01 signal filter + KITOZER-VT-H01 high-efficiency shielding ventilation waveguide + KITOZER-MO-H01 multi-functional monitoring terminal + KITOZER-GD-H01 equipotential grounding system.
  • Solution Advantages: 6mmPb blocks over 99% X-rays & gamma rays below 200keV, military-grade electromagnetic shielding ≥80dB, full welding seamless sealing, constant temperature ventilation, biometric access control & remote intelligent monitoring; complies with GJB 5792-2021 Grade C standard with full confidential military-standard construction.
  • Implementation Steps:
    1. Professional on-site survey & customized military construction plan;
    2. Full welding construction of wall (stainless steel + high-purity lead plate), ceiling & floor with lead-welded sealed joints & anti-corrosion treatment;
    3. Install full hydraulic automatic shielding door & military shielding observation window with five-layer sealing;
    4. Mount high-efficiency shielding waveguides & constant temperature ventilation system, power/signal filters, connect equipotential grounding system (ground resistance ≤0.5Ω);
    5. Install multi-functional monitoring terminal & debug remote monitoring, acoustic-optical alarm & emergency lighting;
    6. Third-party authoritative inspection & acceptance (shielding efficiency, ray leakage rate, ground resistance) before delivery with lifelong technical support.

10.3 Radiation Shielding Lead Plate Solutions

10.3.1 Wall/Ceiling Basic Protection Solution

  • Applicable Scenarios: Basic wall & ceiling protection for small X-ray rooms & industrial flaw detection rooms, low-energy X-ray shielding.
  • Configuration Combination: KITOZER-PB-L01 1mm basic lead plate + special fixing keels + sealing connectors + anti-corrosion coating materials.
  • Solution Advantages: Low cost, easy cutting & installation with simple sealing; standard lead plates in stock for short 1–2 day construction cycle.
  • Implementation Steps:
    1. Clean & level dry base wall/ceiling;
    2. Install fixing keels at 600mm spacing;
    3. Cut lead plates for laying with ≥50mm overlapping seams;
    4. Seal seams with lead welding or lead glue & fix lead plates to keels;
    5. Apply anti-oxidation coating on surface, dry before decorative layer construction.

10.3.2 Integrated CT Room Medical Protection Solution (Standard Grade)

  • Applicable Scenarios: Full wall, floor, ceiling, door & window lining protection for general hospital CT rooms, medical X-ray/CT ray shielding.
  • Configuration Combination: KITOZER-PB-M01 3mm standard lead plate + special fixing keels + lead welding consumables + acid-alkali resistant anti-corrosion coating + lead lining for matching shielding doors & windows.
  • Solution Advantages: Precise 3mmPb protection, corrosion resistant & bendable to fit curved walls, medical-grade disinfectant compatible coating, long service life, 3–5 day construction cycle.
  • Implementation Steps:
    1. Base treatment & load-bearing keel installation;
    2. Lay floor lead plates with lead-welded sealed joints, flatness ≤1.5mm/m;
    3. Lay wall lead plates bottom-up with staggered horizontal/vertical ≥50mm overlapping seams & lead welding sealing;
    4. Lay ceiling lead plates & seal wall-ceiling joints;
    5. Install 3mm lead lining for doors & windows to connect seamlessly with wall lead plates;
    6. Apply acid-alkali resistant anti-oxidation coating on surface, accept ray leakage rate ≤0.001mSv/h.

10.3.3 High-Strength Nuclear Industry Protection Solution (High Grade)

  • Applicable Scenarios: Peripheral protection of nuclear reactors, scientific accelerator laboratories, high-intensity flaw detection rooms, high-strength X-ray/gamma ray shielding.
  • Configuration Combination: KITOZER-PB-H01 6–20mm high-grade lead plate + military-grade fixing keels + high-purity lead welding consumables + nano anti-oxidation coating + customized special-shaped components.
  • Solution Advantages: Ultra-pure lead ≥99.995%, high-precision thickness tolerance, arbitrary bending & welding, military sealing & anti-corrosion, 6–20mmPb for high-intensity radiation scenarios with full confidential production & construction.
  • Implementation Steps:
    1. Professional team designs protection plan & calculates lead plate thickness & layout;
    2. Military-grade load-bearing keel installation & base reinforcement;
    3. Cut, bend & weld lead plates with full lead-welded ≥80mm overlapping seams;
    4. Stack multi-layer lead plates (for higher lead equivalent) with interlayer sealing;
    5. Apply nano anti-oxidation coating for acid & alkali resistance;
    6. Third-party authoritative inspection & acceptance with ray leakage rate below 0.0001mSv/h before delivery.

11. Full Product Application Cases

11.1 Electromagnetic Shielding Box Cases

Case 1: RF Testing Project for a 5G Communication Equipment Manufacturer

  • Project Background: The enterprise required RF interference testing of 5G base station modules with shielding efficiency ≥60dB to block external electromagnetic interference & ensure accurate test data.
  • Product Configuration: KITOZER-SB-M01 pneumatic electromagnetic shielding box + KITOZER-FL-M01 standard power filter + KITOZER-GD-M01 standard grounding device.
  • Project Outcome: Measured shielding efficiency ≥65dB meeting 5G module testing demands; automatic pneumatic operation supports over 200 daily tests with high efficiency; 2 years of failure-free stable operation with consistent test data, winning high customer recognition.

Case 2: Confidential Equipment Protection Project for a Military Research Institute

  • Project Background: The institute needed electromagnetic shielding for confidential communication equipment to prevent information leakage, requiring shielding efficiency ≥80dB complying with GJB 5792-2021 Grade D with full confidentiality control.
  • Product Configuration: KITOZER-SB-H01 full-automatic electromagnetic shielding box + KITOZER-FL-H01 high-grade power filter + KITOZER-SF-H01 signal filter + KITOZER-GD-H01 equipotential grounding system + KITOZER-MO-H01 multi-functional monitoring terminal.
  • Project Outcome: Measured shielding efficiency ≥85dB reaching military confidential standards; full hydraulic automatic drive + biometric access control for maximum safety; real-time remote monitoring with encrypted data recording under full confidentiality; 3 years of stable failure-free operation securing confidential equipment information, securing long-term cooperation orders from the military institute.

11.2 CT & X-ray Shielding Room Cases

Case 1: CT Room Protection Project for a County General Hospital

  • Project Background: The hospital built a new CT room requiring medical CT ray protection (≤150keV) + electromagnetic shielding to ensure staff safety & stable equipment operation with medium budget & tight 10-day delivery deadline.
  • Product Configuration: KITOZER-RS-M01 standard CT shielding room + KITOZER-SD-M01 electric shielding door + KITOZER-SW-M01 shielding observation window + KITOZER-FL-M01 standard power filter + KITOZER-VT-M01 shielding ventilation waveguide + KITOZER-MO-M01 radiation dose monitor.
  • Project Outcome: Completed construction in 9 days ahead of schedule; 3mmPb with measured ray leakage rate ≤0.0008mSv/h far exceeding national standards; electromagnetic shielding ≥62dB for interference-free CT operation; convenient electric door & real-time radiation alarm fully protecting medical staff, winning a commendation banner from the hospital.

Case 2: Accelerator Laboratory Shielding Project for a Nuclear Industry Research Institute

  • Project Background: The institute constructed a new high-energy accelerator laboratory requiring protection for ≤200keV high-intensity X-rays & gamma rays plus military-grade ≥80dB electromagnetic shielding, full confidential construction with 20-day delivery & third-party authoritative acceptance.
  • Product Configuration: KITOZER-RS-H01 high-grade shielding room + KITOZER-SD-H01 full-automatic shielding door + KITOZER-SW-H01 shielding observation window + KITOZER-FL-H01 high-grade power filter + KITOZER-SF-H01 signal filter + KITOZER-VT-H01 high-efficiency shielding ventilation waveguide + KITOZER-MO-H01 multi-functional monitoring terminal + KITOZER-GD-H01 equipotential grounding system.
  • Project Outcome: Military full-welding construction finished in 18 days ahead of schedule; 6mmPb with measured ray leakage rate ≤0.00005mSv/h; electromagnetic shielding ≥88dB complying with GJB 5792-2021 Grade C standard; constant temperature ventilation & intelligent remote monitoring maintaining stable laboratory environment; one-time pass of third-party inspection under full confidential construction, earning high praise from the nuclear institute & a long-term cooperation framework agreement.

11.3 Radiation Shielding Lead Plate Cases

Case 1: X-ray Room Protection Project for a Community Clinic

  • Project Background: The clinic installed a new X-ray machine requiring basic wall & door ray protection with low budget & 2-day fast construction to shield low-energy X-rays & protect medical staff & patients.
  • Product Configuration: KITOZER-PB-L01 1mm basic lead plate + special fixing keels + sealing connectors + anti-oxidation coating materials.
  • Project Outcome: Construction completed in 1.5 days for fast delivery; 1mmPb with measured ray leakage rate ≤0.002mSv/h meeting basic protection demands; easily cut & installed lead plates matching tight clinic budget; 1 year of stable oxidation-free operation with consistent shielding performance, securing long-term procurement intent from the clinic.

Case 2: Integrated Interventional Operating Room Protection Project for a Grade A Tertiary Hospital

  • Project Background: The hospital’s interventional operating room required full ray protection (≤150keV) covering walls, floors, ceilings, shielding doors & window linings, demanding 3mmPb, acid-alkali resistance & easy cleaning for medical environments with 5-day construction cycle.
  • Product Configuration: KITOZER-PB-M01 3mm standard lead plate + special fixing keels + lead welding consumables + acid-alkali resistant anti-oxidation coating + lead lining for matching shielding doors & windows.
  • Project Outcome: Construction finished in 4 days ahead of schedule; well-sealed lead plate joints with measured ray leakage rate ≤0.0006mSv/h; acid-alkali resistant coating tolerates frequent medical disinfectant contact with easy surface cleaning; 3 years of oxidation & deformation-free stable shielding performance, winning the title of Annual Excellent Supplier from the hospital.
Shopping Cart