Table of Contents
Toggle1. System Overview
KITOZER steel plate welded shield enclosure serves as the core protective carrier of shielded rooms. It is fabricated from high-quality cold-rolled steel plates via CNC bending and full penetration welding with COâ‚‚ gas shielded welding, forming a fully sealed six-sided metal shielding space. Based on electromagnetic shielding principles, the metal enclosure blocks internal and external electromagnetic signal conduction and radiation through electromagnetic wave reflection, absorption and multiple reflection losses, delivering three core functions: electromagnetic isolation, confidential information protection and equipment safeguarding.
The system strictly complies with national and military standards including BMB3-1999 (Class C), GJB5792-2006 and GB12190-2006. It features high shielding effectiveness, robust structural strength, outstanding stability and long service life. Customizable to fit confidential computer rooms, EMC test chambers, data centers, command centers and other scenarios, it effectively resists electromagnetic interference, signal leakage and external electromagnetic attacks to secure classified information and stable operation of electronic equipment.
Steel Plate Welded Shield Enclosure
2. System Composition
The KITOZER steel plate welded shield enclosure system consists of three major parts: core shielding main body, dedicated shielding accessories and auxiliary supporting systems. All components work in synergy to guarantee shielding integrity and system stability.
2.1 Main Shield Enclosure Body
Fully welded six-sided structure, including 3mm cold-rolled steel base plate, 2mm cold-rolled steel top plate and four 2mm cold-rolled steel wall panels. A rectangular tube keel support frame is built inside; a 5mm high-strength insulation board is laid at the bottom for moisture-proof insulation, and the top is reinforced for rigidity.
Welded Shield Enclosure Segment
2.2 Special Shielding Accessories
- Shielded Door: Manual/electric blade-type electromagnetic sealing door with 1.2mm thickened steel plate, double-groove beryllium copper spring strips, contact impedance ≤0.1Ω to ensure electromagnetic continuity of the door body.
- Ventilation Waveguide Window: Fully welded honeycomb structure (300mm×300mm×50mm) with vacuum brazed hexagonal aluminum honeycomb arrays and an aperture ratio of 18, balancing ventilation and shielding performance.
- Power/Signal Filters: Power filters (10A/20A/30A) and signal filters (RJ45/fiber/serial port) with insertion loss ≥100dB to block conducted electromagnetic signals through circuits.
- Waveguide Tubes / Cable Penetration Plates: Special cable routing components for optical fibers, network cables and power cords to prevent shielding leakage at cable penetration points.
2.3 Auxiliary Supporting Systems
- Earthing System: Dedicated shielding earth electrodes, 40×4mm copper busbars and earthing cables, with earthing resistance ≤1Ω to stabilize the potential of the enclosure.
- Anti-Corrosion & Rust Prevention System: Double-sided galvanization of the enclosure (≥12μm) plus anti-corrosion paint coating (RAL7035) to boost corrosion resistance.
- Indoor Decoration System: Anti-static floor, micro-perforated aluminum ceiling and flame-retardant sound-absorbing wall materials to meet computer room environmental requirements.
3. System Classification
Classified by shielding grade, structural specification and application scenario into three types to match different security and performance requirements:
3.1 Basic Type (Low Configuration)
- Shielding Grade: Meets basic Class C standard of BMB3-1999
- Material Specification: 2.5mm base plate, 1.5mm wall/top cold-rolled steel plates, ordinary rectangular tube keel
- Shielding Effectiveness: ≥60dB @14KHz, ≥80dB @200KHz, ≥80dB @1MHz–1GHz
- Applicable Scenarios: General office confidential computer rooms, small data rooms, non-core confidential areas
3.2 Standard Type (Medium Configuration)
Enclosure Structural Drawing
- Shielding Grade: Complies with BMB3-1999 Class C and GJB5792-2006 Class D standards
- Material Specification: 3mm base plate, 2mm wall/top cold-rolled steel plates, thickened rectangular tube keel with local reinforcing ribs
- Shielding Effectiveness: ≥70dB @14KHz, ≥100dB @200KHz, ≥95dB @1MHz–10GHz
- Applicable Scenarios: Government confidential computer rooms, financial data centers, scientific research laboratories, medium-sized command centers
3.3 Enhanced Type (High Configuration)
- Shielding Grade: Satisfies BMB3-1999 Class C, GJB5792-2006 Class C and high-grade NSA 65-6 standards
- Material Specification: 4mm base plate, 3mm wall/top premium cold-rolled steel plates, high-strength section steel keel with full cabin reinforcement structure
- Shielding Effectiveness: ≥80dB @14KHz, ≥110dB @200KHz, ≥100dB @1MHz–10GHz, ≥80dB for millimeter waves
- Applicable Scenarios: Military command centers, national-level confidential computer rooms, high-end EMC test chambers, satellite communication rooms
4. System Working Principle
On-site Installation & Wiring
External electromagnetic signals → Steel plate welded six-sided shield enclosure → Loss via reflection, absorption and multiple reflections → No electromagnetic leakage inside the chamber
Internal electromagnetic signals → Steel plate welded six-sided shield enclosure → Loss via reflection, absorption and multiple reflections → No electromagnetic radiation outside the chamber
Interface shielding logic of the enclosure:
- Shielded Door: Sealed by spring strips to maintain electromagnetic continuity
- Ventilation Waveguide Window: Honeycomb arrays realize ventilation while retaining shielding performance
- Power/Signal Filters: Circuit isolation blocks conducted signal transmission
- Waveguide Tubes / Cable Penetration Plates: Cable shielding eliminates leakage at penetration points
Earthing system flow: Shield enclosure → Earthing copper busbar → Earth electrode → Ground (earthing resistance ≤1Ω)
5. Full System Configuration List
5.1 Low Configuration (Basic Type)
è¡¨æ ¼
| No. | Product Name | Model & Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Shield Enclosure Base Plate | KITOZER-PB-2.5 | 2.5mm cold-rolled steel, customized size, galvanized + anti-corrosion paint | 1 | Set | KITOZER | Includes support keel & insulation board |
| 2 | Shield Enclosure Wall Panel | KITOZER-PW-1.5 | 1.5mm cold-rolled steel, customized size, galvanized + anti-corrosion paint | 4 | Set | KITOZER | Includes reinforcing ribs & welding accessories |
| 3 | Shield Enclosure Top Plate | KITOZER-PT-1.5 | 1.5mm cold-rolled steel, customized size, galvanized + anti-corrosion paint | 1 | Set | KITOZER | Includes ceiling connectors & reinforcement treatment |
| 4 | Manual Shielded Door | KITOZER-PD-M-850 | 1900×850mm, 1.2mm steel plate, single-blade spring strip, manual locking | 1 | Leaf | KITOZER | Includes door frame, lock & sealing spring strips |
| 5 | Ventilation Waveguide Window | KITOZER-WW-300-50 | 300×300×50mm, aluminum honeycomb, welded structure | 2 | Pc. | KITOZER | Includes mounting frame & sealing rubber strip |
| 6 | Power Filter | KITOZER-PF-10A | 220V/10A, insertion loss ≥80dB, 50MHz–1GHz | 1 | Unit | KITOZER | Single-phase, wall-mounted |
| 7 | Signal Filter | KITOZER-SF-RJ45 | RJ45 interface, insertion loss ≥80dB, 1MHz–1GHz | 4 | Pc. | KITOZER | Dedicated for network signals |
| 8 | Earthing Copper Busbar | KITOZER-GP-40×4 | 40×4mm tinned pure copper, customized length | 1 | Set | KITOZER | Includes connecting terminals & fasteners |
| 9 | Insulation Board | KITOZER-IB-5mm | 5mm high-strength flame-retardant moisture-proof insulation board | 1 | Set | KITOZER | Special for bottom insulation of enclosure |
5.2 Medium Configuration (Standard Type)
è¡¨æ ¼
| No. | Product Name | Model & Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Shield Enclosure Base Plate | KITOZER-PB-3.0 | 3mm cold-rolled steel, customized size, hot-dip galvanized + anti-corrosion paint | 1 | Set | KITOZER | Includes thickened keel, insulation board & load-bearing reinforcement |
| 2 | Shield Enclosure Wall Panel | KITOZER-PW-2.0 | 2mm cold-rolled steel, customized size, hot-dip galvanized + anti-corrosion paint | 4 | Set | KITOZER | Includes reinforcing ribs, welding accessories, column & beam wrapping |
| 3 | Shield Enclosure Top Plate | KITOZER-PT-2.0 | 2mm cold-rolled steel, customized size, hot-dip galvanized + anti-corrosion paint | 1 | Set | KITOZER | Includes ceiling connectors & rigidity reinforcement |
| 4 | Electric Shielded Door | KITOZER-PD-E-850 | 1900×850mm, 1.5mm steel plate, double-blade spring strips, electric + manual dual mode | 1 | Leaf | KITOZER | Includes frame, electric lock, spring strips & controller |
| 5 | Ventilation Waveguide Window | KITOZER-WW-300-50 | 300×300×50mm vacuum brazed aluminum honeycomb, welded structure | 4 | Pc. | KITOZER | Includes frame, rubber strip & rain shield |
| 6 | Power Filter | KITOZER-PF-20A | 220V/20A, insertion loss ≥100dB, 14KHz–10GHz | 2 | Unit | KITOZER | Single-phase rack-mounted, redundant configuration |
| 7 | Signal Filter | KITOZER-SF-RJ45-P | RJ45 interface, insertion loss ≥100dB, 14KHz–10GHz | 8 | Pc. | KITOZER | Matched with shielded network cables |
| 8 | Waveguide Tube | KITOZER-WG-Φ50 | Φ50mm stainless steel, customized length, double-end sealing | 2 | Pc. | KITOZER | For optical fiber & weak current wiring |
| 9 | Earthing Copper Busbar | KITOZER-GP-50×5 | 50×5mm tinned pure copper, customized length | 1 | Set | KITOZER | Includes terminals, fasteners & earthing cables |
| 10 | Insulation Board | KITOZER-IB-8mm | 8mm flame-retardant, moisture-proof & anti-aging high-strength insulation board | 1 | Set | KITOZER | Special for bottom insulation of enclosure |
5.3 High Configuration (Enhanced Type)
è¡¨æ ¼
| No. | Product Name | Model & Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Shield Enclosure Base Plate | KITOZER-PB-4.0 | 4mm premium cold-rolled steel, customized size, hot-dip galvanized + heavy-duty anti-corrosion paint | 1 | Set | KITOZER | Includes high-strength section steel keel, insulation board & load distribution frame |
| 2 | Shield Enclosure Wall Panel | KITOZER-PW-3.0 | 3mm premium cold-rolled steel, customized size, hot-dip galvanized + heavy-duty anti-corrosion paint | 4 | Set | KITOZER | Full-cabin reinforcing ribs, welding accessories & special-shaped customization |
| 3 | Shield Enclosure Top Plate | KITOZER-PT-3.0 | 3mm premium cold-rolled steel, customized size, hot-dip galvanized + heavy-duty anti-corrosion paint | 1 | Set | KITOZER | Ceiling connectors & high-rigidity reinforcement |
| 4 | Electric Shielded Door | KITOZER-PD-E-900 | 1900×900mm, 2.0mm steel plate, triple-blade beryllium copper spring strips, explosion-proof electric/manual dual mode | 1 | Leaf | KITOZER | Frame, electric lock, intelligent controller included |
| 5 | Ventilation Waveguide Window | KITOZER-WW-400-60 | 400×400×60mm vacuum brazed aluminum honeycomb, high-frequency enhanced | 6 | Pc. | KITOZER | Frame, rubber strip, rain shield & insect screen included |
| 6 | Power Filter | KITOZER-PF-30A | 380V/30A, insertion loss ≥110dB, 14KHz–18GHz, lightning protection | 3 | Unit | KITOZER | Three-phase rack-mounted, redundant configuration |
| 7 | Signal Filter | KITOZER-SF-RJ45-H | RJ45 interface, insertion loss ≥110dB, 14KHz–18GHz, military-grade shielding | 16 | Pc. | KITOZER | Dedicated for network transmission |
| 8 | Waveguide Tube | KITOZER-WG-Φ80 | Φ80mm stainless steel, customized length, double-end high-frequency sealing | 4 | Pc. | KITOZER | For optical fiber & weak current wiring |
| 9 | Cable Penetration Plate | KITOZER-CB Custom | Custom size, welded steel plate with multi-size sealed cable holes | 1 | Set | KITOZER | Separate routing for strong & weak currents |
| 10 | Earthing Copper Busbar | KITOZER-GP-60×6 | 60×6mm low-resistance tinned T2 pure copper, customized length | 1 | Set | KITOZER | Terminals, cables & resistance reducing agent included |
| 11 | Insulation Board | KITOZER-IB-10mm | 10mm flame-retardant, moisture-proof, anti-aging & high-voltage resistant insulation board | 1 | Set | KITOZER | Special for bottom insulation of enclosure |
6. Full Product Technical Parameters
6.1 Shield Enclosure (General Parameters for All Configurations)
Enclosure Layout Drawing
- Material: Premium SPCC cold-rolled steel plate, chemical composition complies with GB/T709
- Plate Thickness: Basic (2.5mm base, 1.5mm wall/top); Standard (3mm base, 2mm wall/top); Enhanced (4mm base, 3mm wall/top)
- Welding Process: CO₂ gas shielded full penetration welding, weld width ≥8mm, weld gap ≤0.2mm, free of pores, slag inclusions and cracks
- Surface Treatment: Hot-dip galvanized layer ≥12μm, RAL7035 anti-corrosion paint coating, adhesion Grade 1, salt spray resistance ≥500h
- Shielding Effectiveness: Basic: ≥60dB @14KHz, ≥80dB @200KHz, ≥80dB @1MHz–1GHz Standard: ≥70dB @14KHz, ≥100dB @200KHz, ≥95dB @1MHz–10GHz Enhanced: ≥80dB @14KHz, ≥110dB @200KHz, ≥100dB @1MHz–10GHz, ≥80dB for millimeter waves
- Insulation Resistance: ≥5MΩ between enclosure and ground (tested by 500V megohmmeter)
- Earthing Resistance: ≤1Ω (independent earth electrode)
6.2 Shielded Door
- Material: 1.2/1.5/2.0mm cold-rolled steel door leaf, 2.5/3.0mm steel frame, QBe2.0 beryllium copper spring strips
- Standard Size: 1900×850mm / 1900×900mm, custom sizes available
- Sealing Structure: Single/double/triple-blade insertion type, double-groove spring strips, contact impedance ≤0.1Ω
- Opening Mode: Manual / Electric (electric power ≤150W, 220V), electric response time ≤3s, manual locking force ≤50N
- Shielding Consistency: Matches enclosure shielding grade; shielding effectiveness attenuation ≤5dB after 100,000 opening/closing cycles
6.3 Ventilation Waveguide Window
- Material: 3003 aluminum honeycomb, cold-rolled steel frame, welded assembly
- Size: 300×300×50mm / 400×400×60mm, honeycomb aperture ≤5mm, hole spacing ≤6mm
- Welding Process: Vacuum brazing, seamless honeycomb array, welding strength ≥20MPa
- Ventilation Volume: ≥300m³/h for 300×300mm window; ≥500m³/h for 400×400mm window
- Shielding Effectiveness: ≥95dB @14KHz–10GHz, consistent with enclosure performance
6.4 Power Filter
Completed Shield Enclosure Chamber
- Rated Voltage: 220V (single-phase) / 380V (three-phase), 50/60Hz
- Rated Current: 10A/20A/30A, customizable
- Insertion Loss: Basic ≥80dB @50MHz–1GHz; Standard ≥100dB @14KHz–10GHz; Enhanced ≥110dB @14KHz–18GHz
- Operating Temperature: -25℃ ~ +70℃, relative humidity ≤85% (no condensation)
- Withstand Voltage: Line-to-line ≥2000VAC, line-to-ground ≥1500VAC, no breakdown within 1 minute
6.5 Signal Filter
- Interface Types: RJ45 (network), DB9 (serial), Fiber (SC/FC/LC), audio, etc.
- Insertion Loss: Consistent with power filter, matched to corresponding frequency bands
- Transmission Rate: RJ45 supports 10/100/1000Mbps; Fiber supports 10Gbps
- Operating Temperature: -25℃ ~ +70℃, relative humidity ≤85% (no condensation)
6.6 Earthing Copper Busbar
Internal Shielded Command Room
7.1 Shield Enclosure
- Confidential Fields: Government confidential computer rooms, military command centers, public security & state security confidential offices, national-level exam centers
- Data Centers: Bank financial data rooms, operator core computer rooms, internet enterprise server rooms
- Scientific Research & Testing: University EMC laboratories, precision instrument rooms of research institutes, enterprise EMC test chambers
- Special Scenarios: Satellite communication rooms, medical MRI rooms, industrial automation control rooms, confidential archives storage rooms
7.2 Shielded Door
For entrances of all shielded rooms, confidential passages, secure rooms and electromagnetic test chambers; maintains shielding integrity during personnel access.
7.3 Ventilation Waveguide Window
Special ventilation & heat dissipation component for shielded rooms, replacing ordinary ventilation windows to resolve the conflict between air exchange and shielding performance; compatible with air conditioning and fresh air outlets of computer rooms.
7.4 Power/Signal Filters
Dedicated for power and signal lines inside shielded rooms. Blocks external electromagnetic signals intruding via cables and prevents internal confidential signals leaking through circuits; applicable to all incoming/outgoing power cords, network cables, optical fibers, fire control wires and access control cables.
7.5 Waveguide Tubes / Cable Penetration Plates
Special cable routing components for shield enclosure penetration, eliminating electromagnetic leakage at cable crossing points; supports multi-specification cables with separated routing for strong and weak currents.
7.6 Earthing System
Special shielding & safety earthing for shielded rooms. Stabilizes enclosure potential, prevents static accumulation and lightning damage, and mitigates electromagnetic interference; adapts to earthing requirements for all geological conditions.
8. Core Product Advantages
Internal Frame Structure of Shield Enclosure
8.1 Advantages of Shield Enclosure
- High-performance Shielding: Full welding process eliminates mechanical gaps, stable shielding effectiveness far superior to assembled structures; attenuation ≤3dB after 10 years of service, avoiding shielding failure caused by loose seams.
- Ultra-high Structural Strength: Premium cold-rolled steel + section steel keel with seismic resistance ≥Grade 8; withstands loads of top-mounted equipment and ceiling systems, supports complex infrastructure including column & beam wrapping and special-shaped spaces.
- Fully Customized Production: Size and shape tailor-made to fit all computer room layouts; non-standard structures designed per site conditions to maximize space utilization.
- Outstanding Corrosion Resistance: Dual protection of hot-dip galvanization + heavy anti-corrosion paint, salt spray resistance ≥500h, moisture/rust/aging resistance, service life ≥20 years, suitable for humid and dusty harsh environments.
- Confidential-Grade Craftsmanship: Fully sealed welding with zero assembly gaps, extremely low risk of electromagnetic leakage, fully compliant with national confidentiality standards to secure classified information.
- Spot Goods & OEM/ODM: Standard specifications in stock for delivery within 72 hours; supports OEM/ODM customized production per customer drawings and parameters with flexible demand adaptation.
8.2 Advantages of Shielded Door
- Military-Grade Sealing: Beryllium copper spring strips with excellent elasticity and conductivity, no fatigue deformation after 100,000 opening cycles, stable contact impedance ≤0.1Ω with zero shielding leakage.
- Dual Opening Modes: Electric + manual backup; manual operation available during power outages for emergency access; intelligent electric control supports access control linkage and remote door operation.
- High Security: Explosion-proof design with thickened door leaf against violent damage; dual-locking mechanism prevents unauthorized entry, meeting high security requirements of confidential zones.
8.3 Advantages of Ventilation Waveguide Window
- High Ventilation Efficiency: Honeycomb array design delivers large air volume and low wind resistance to meet computer room heat dissipation demands and reduce air conditioning energy consumption.
- Stable High-Frequency Shielding: Vacuum brazing eliminates honeycomb gaps, stable shielding effectiveness ≥95dB above 1GHz for high-frequency electromagnetic environments.
- Easy Installation & Maintenance: Modular design for convenient mounting and independent disassembly/replacement, low maintenance cost.
8.4 Advantages of Power & Signal Filters
- Wideband High Attenuation: Full coverage of 14KHz–18GHz frequency band, insertion loss ≥80dB for basic models and ≥110dB for military-grade products to block full-spectrum electromagnetic signals.
- High Operational Stability: Industrial-grade components with operating temperature range -25℃~+70℃, long-term failure-free operation, MTBF ≥100,000 hours.
- Plug-and-Play: Standard interfaces for simple installation without complex debugging; separated strong/weak current filters to avoid mutual interference.
8.5 Overall Service Advantages
- Full-Cycle Customization: One-stop service covering scheme design, drawing deepening, manufacturing, on-site installation, testing & commissioning and after-sales maintenance with dedicated follow-up throughout the project.
- Confidentiality Qualifications: Possesses classified information system integration and shielded room testing qualifications; products certified by State Secrets Bureau with official test reports available.
- Fast Delivery: Standard products in stock; production cycle ≤15 days for non-standard products, on-site installation ≤7 days to shorten project timeline.
- Lifelong Maintenance: 1-year free warranty for all products, lifelong maintenance service, 24-hour technical support with fault response within 2 hours to guarantee long-term stable system operation.
9. Bid Evaluation Control Parameters (*Marked Mandatory Indicators)
9.1 Shield Enclosure
- *Material: Premium SPCC cold-rolled steel plate; base plate ≥2.5mm (Basic) / ≥3mm (Standard) / ≥4mm (Enhanced); wall & top plate ≥1.5mm (Basic) / ≥2mm (Standard) / ≥3mm (Enhanced)
- *Welding Process: CO₂ gas shielded full penetration welding, weld gap ≤0.2mm, free of pores and slag inclusions
- *Shielding Effectiveness: ≥60dB @14KHz (Basic) / ≥70dB (Standard) / ≥80dB (Enhanced); ≥80dB @200KHz (Basic) / ≥100dB (Standard) / ≥110dB (Enhanced); ≥80dB @1MHz–10GHz (Basic) / ≥95dB (Standard) / ≥100dB (Enhanced)
- *Surface Treatment: Hot-dip galvanized layer ≥12μm, anti-corrosion paint coating, salt spray resistance ≥500h
- *Insulation Resistance: ≥5MΩ between enclosure and ground (500V megohmmeter test)
9.2 Shielded Door
- *Size: Standard 1900×850mm (customizable); door leaf thickness ≥1.2mm (Basic) / ≥1.5mm (Standard) / ≥2.0mm (Enhanced)
- *Sealing Structure: Single/double/triple-blade insertion type with beryllium copper spring strips, contact impedance ≤0.1Ω
- *Shielding Consistency: Matches enclosure shielding grade; attenuation ≤5dB after 100,000 opening/closing cycles
9.3 Ventilation Waveguide Window
Welding Production Workshop
- *Size: 300×300×50mm (Standard) / 400×400×60mm (Enhanced), vacuum brazed aluminum honeycomb
- *Shielding Effectiveness: ≥95dB @14KHz–10GHz
- *Ventilation Volume: ≥300m³/h for 300×300mm window
9.4 Power Filter
- *Rated Current: Optional 10A/20A/30A; rated voltage 220V/380V
- *Insertion Loss: ≥80dB @50MHz–1GHz (Basic) / ≥100dB @14KHz–10GHz (Standard) / ≥110dB @14KHz–18GHz (Enhanced)
- *Operating Temperature: -25℃ ~ +70℃
9.5 Signal Filter
- *Interfaces: Optional RJ45/DB9/Fiber; insertion loss consistent with power filter
- *Transmission Rate: RJ45 supports 1000Mbps; Fiber supports 10Gbps
9.6 Earthing Copper Busbar
- *Material: T2 pure copper with tin plating, minimum specification 40×4mm; earthing resistance ≤1Ω
10. All-in-One Product Solutions
10.1 Confidential Computer Room Shielding Solution
- Pain Points: Prevent electromagnetic leakage of classified information, resist external electromagnetic interference, comply with BMB3-1999 Class C national confidentiality standard
- Configuration Scheme: Standard shield enclosure (3mm base + 2mm wall/top plates) + electric shielded door + 4 ventilation waveguide windows + 2×20A power filters + 8×RJ45 signal filters + complete earthing system
- Implementation Key Points: Full welding of enclosure, bottom insulation treatment, shield sealing of all interfaces (doors, windows, cables), independent earth electrode with earthing resistance ≤1Ω, post-completion inspection & certification by State Secrets Bureau
- Outcome: Shielding effectiveness ≥95dB @14KHz–10GHz, zero electromagnetic leakage, fully meets classified information security requirements
10.2 Financial Data Center Shielding Solution
- Pain Points: Secure financial data, prevent data theft via electromagnetic signals, resist external electromagnetic interference for stable server 24/7 operation
- Configuration Scheme: Enhanced shield enclosure (4mm base + 3mm wall/top plates) + electric explosion-proof shielded door + 6 high-frequency ventilation waveguide windows + 3×30A three-phase power filters + 16×RJ45 signal filters + waveguide tubes + integrated earthing & lightning protection system
- Implementation Key Points: High-strength section steel keel with load distribution frame, reinforced high-frequency shielding, separated routing for strong/weak currents, integrated lightning & shielding earthing design for 7×24-hour uninterrupted operation
- Outcome: Shielding effectiveness ≥100dB @14KHz–18GHz, blocks 5G and millimeter-wave electromagnetic attacks, zero data leakage, server operational stability improved to 99.99%
10.3 Scientific Research EMC Test Chamber Solution
- Pain Points: Provide pure electromagnetic environment, avoid external interference distorting test results, contain test signal radiation, comply with GJB5792-2006 military standard
- Configuration Scheme: Custom-sized enhanced shield enclosure + electric shielded door + customized high-frequency ventilation waveguide windows + wideband power filters + multi-type signal filters + matching wave-absorbing materials
- Implementation Key Points: Custom design for irregular spaces, full-cabin reinforcement, enhanced millimeter-wave shielding, internal wave-absorbing material laying to meet full-band EMC testing requirements
- Outcome: Shielding effectiveness ≥90dB @14KHz–40GHz, indoor electromagnetic noise ≤-100dBμV/m for accurate and reliable test data
10.4 Small Office Confidential Computer Room Solution
- Pain Points: Low-cost basic electromagnetic shielding for small-space daily classified information protection
- Configuration Scheme: Basic shield enclosure (2.5mm base + 1.5mm wall/top plates) + manual shielded door + 2 ventilation waveguide windows + 1×10A power filter + 4×RJ45 signal filters + simplified earthing system
- Implementation Key Points: Pre-fabricated standard modules for fast on-site welding installation, simplified interface configuration to cut costs while meeting basic confidentiality standards
- Outcome: Shielding effectiveness ≥80dB @14KHz–1GHz, blocks daily electromagnetic leakage for small office confidential scenarios
11. Product Application Cases
Case 1: Provincial Government Core Confidential Computer Room Project
- Project Overview: 80㎡, 3m height core confidential room for provincial government, compliant with BMB3-1999 Class C, shielding effectiveness ≥95dB @14KHz–10GHz
- Product Configuration: KITOZER standard shield enclosure, 1 electric shielded door, 4 ventilation waveguide windows, 2×20A power filters, 8×RJ45 signal filters, 1 full earthing system
- Implementation Process: Site survey → drawing deepening → prefabrication → 7-day on-site welding → interface installation → earthing construction → testing & commissioning → acceptance & delivery
- Operation Effect: Passed State Secrets Bureau inspection with full shielding compliance; 3 years of failure-free operation with zero electromagnetic leakage to secure provincial classified information
Case 2: Head Office Bank Data Center Shielding Renovation Project
- Project Overview: 200㎡, 4m height core financial data room requiring shielding upgrade to prevent financial data leakage and resist high-frequency electromagnetic attacks
- Product Configuration: KITOZER enhanced shield enclosure, 1 electric explosion-proof shielded door, 6 high-frequency ventilation waveguide windows, 3×30A three-phase power filters, 16×RJ45 signal filters, 4 waveguide tubes, integrated earthing system
- Implementation Process: Old room renovation → load-bearing reinforcement → enclosure welding → high-frequency shielding optimization → separated cable routing → integrated lightning & shielding earthing construction → 72-hour continuous testing → acceptance
- Operation Effect: Shielding effectiveness ≥100dB @14KHz–18GHz, blocks 5G and millimeter-wave interference, zero data leakage, server stability upgraded to 99.99%
Case 3: University EMC Laboratory Construction Project
- Project Overview: 50㎡, 3.5m height laboratory for electronic device EMC testing, requiring pure electromagnetic environment with shielding effectiveness ≥90dB @14KHz–40GHz
- Product Configuration: Custom KITOZER enhanced shield enclosure, 1 electric shielded door, 3 customized high-frequency ventilation waveguide windows, 2 wideband power filters, 10 multi-type signal filters, matching wave-absorbing materials
- Implementation Process: Irregular space design → customized enclosure production → on-site welding assembly → high-frequency shielding optimization → wave-absorbing material laying → full-band calibration testing → delivery
- Operation Effect: Indoor electromagnetic noise ≤-100dBμV/m, supports full-category EMC testing for mobile phones, routers and electronic equipment with precise test data, highly recognized by the university
Case 4: State-Owned Enterprise Small Confidential Computer Room Project
- Project Overview: 20㎡, 2.8m height department-level confidential room with limited budget for basic electromagnetic shielding
- Product Configuration: KITOZER basic shield enclosure, 1 manual shielded door, 2 ventilation waveguide windows, 1×10A power filter, 4×RJ45 signal filters, simplified earthing system
- Implementation Process: Standard prefabricated modules → 3-day fast on-site welding → simple interface installation → earthing construction → basic performance testing → delivery
- Operation Effect: Shielding effectiveness ≥80dB @14KHz–1GHz, meets daily classified information protection demands with high cost performance for small office scenarios
12. Common Product Failures & Maintenance Guidelines
12.1 Common Faults & Troubleshooting
- Degraded Shielding Effectiveness
- Causes: Cracked enclosure welds, aged/deformed shield door spring strips, enlarged honeycomb gaps of waveguide windows, damaged filters, poor earthing
- Solutions: Reweld cracked seams; replace deformed spring strips and adjust door gaps; re-braze or replace defective waveguide windows; test and replace failed filters; tighten earthing connections to ensure resistance ≤1Ω
- Sticky Shielded Door / Poor Sealing
- Causes: Loose lock mechanism, deformed spring strips, sagging door leaf, dust accumulation on guide rails
- Solutions: Tighten lock bolts and adjust locking force; replace deformed spring strips; adjust door hinges to correct sagging; clean guide rails and apply special lubricant
- Failed Power/Signal Filters
- Causes: Overvoltage burnout, component aging, circuit short-circuit, water ingress & dampness
- Solutions: Power off for inspection, replace burnt components or whole filters; troubleshoot short-circuits; dry damp equipment and reinforce waterproof & moisture-proof protection
- Excessive Earthing Resistance
- Causes: Corroded earth electrodes, broken earthing cables, oxidized connecting terminals, dry soil
- Solutions: Replace corroded earth electrodes; repair or replace broken cables; polish oxidized terminals and re-connect; add resistance reducing agent and water soil to lower resistance
12.2 Maintenance Schedules
- Monthly Routine Maintenance
- Visual Inspection: Check enclosure welds and coating for cracks, peeling and rust; repair anti-corrosion paint promptly
- Shielded Door Maintenance: Inspect spring strips for deformation and looseness, wipe dust and apply conductive grease; test opening flexibility and adjust lock tightness
- Interface Inspection: Check sealing integrity of waveguide windows, filters and penetration plates for looseness and leakage traces
- Earthing Inspection: Tighten copper busbar and terminal connections, measure earthing resistance to ensure ≤1Ω
- Quarterly Maintenance (Every 3 Months)
- Full Cleaning: Remove internal & external enclosure dust, clear honeycomb clogging on waveguide windows to avoid ventilation obstruction
- Performance Testing: Test shielding effectiveness at key frequency bands with dedicated tester, record data and resolve abnormalities timely
- Component Fastening: Retighten all enclosure keel, welding node and equipment fixing bolts to prevent deformation from loosening
- Annual Deep Maintenance (Once Per Year)
- Full-Band Shielding Test: Complete 14KHz–18GHz full-spectrum shielding effectiveness test, compare with initial data to assess attenuation
- Aging Component Replacement: Inspect spring strips, filters and other vulnerable parts over 5 years old, replace aging components as needed
- Anti-Corrosion Reinforcement: Re-spray anti-corrosion paint on enclosure surfaces, focus on repairing rusted and worn areas to extend service life
- System Calibration: Recalibrate filters and earthing systems to guarantee performance compliance
- Long-Term Shutdown Maintenance
- Power Cut & Disconnection: Switch off all power supplies, disconnect filters and equipment to avoid overvoltage damage
- Moisture & Dust Prevention: Close shielded doors and waveguide windows, place desiccants inside and cover dust-proof covers to block moisture and dust ingress
- Quarterly Inspection: Check sealing and dryness every 3 months to prevent component aging and rust
13. Factory Strength & After-Sales Service
13.1 Factory Strength
Founded in 2002, KITOZER (Guangzhou Lai’an Intelligent System Development Co., Ltd.) is a leading domestic integrated enterprise specializing in R&D, production and installation of shielded room equipment. Our 10,000㎡ factory is located in Panyu District, Guangzhou, equipped with CNC laser cutters, CNC bending machines, automatic welding robots, electrostatic spraying production lines and an in-house shielding effectiveness testing laboratory. Annual output exceeds 100,000 square meters of shield enclosures and 50,000 sets of shielded doors, filters and other accessories.
- Technical Team: 30+ professional technicians including 5 senior engineers with over 10 years of dedicated shielding technology research, holding more than 20 patents (5 invention patents) and participating in drafting shielded room industry standards
- Production Craftsmanship: Dual production mode of fully automatic assembly lines + manual precision finishing; steel cutting accuracy ±0.1mm, 100% qualified welding, uniform surface treatment, ISO9001 quality management system & ISO14001 environmental management system certified
- Independent Testing Capacity: Self-built national-grade shielding effectiveness laboratory with professional shielding testers and electromagnetic environment analyzers, supporting full-band testing from 14KHz to 40GHz and issuing authoritative test reports; 100% factory pass rate for all products
- Supply Chain Advantages: Long-term strategic cooperation with major domestic steel manufacturers and electronic component suppliers for stable premium raw materials, low procurement cost and high product cost performance
13.2 After-Sales Service
- Warranty Commitment: 1-year free warranty for all products; free repair and replacement of non-artificial damaged components within warranty period; lifelong structural warranty for shield enclosures and permanent free technical support
- Fast Response: 8 national after-sales service centers (Guangzhou, Beijing, Shanghai, Chengdu, Wuhan, Xi’an, Shenyang, Jinan), 24-hour service hotline, fault response within 2 hours, on-site service within 4 hours for first-tier cities and 24 hours for second & third-tier cities
- Installation & Commissioning: Certified professional installation teams provide free on-site installation, commissioning and testing; supply detailed installation drawings, operation manuals and maintenance handbooks, free operator training for independent equipment operation
- Permanent Technical Support: Lifetime free technical consultation, remote debugging and technical document updates; regular release of maintenance guides and industry updates to resolve all operational issues
- Spare Parts Reserve: National spare parts warehouse with stock of vulnerable parts including spring strips, filters, door locks and sealing strips; free replacement within warranty, preferential supply post-warranty to shorten equipment downtime
14. Conclusion
As the core protective product of shielded rooms, KITOZER steel plate welded shield enclosures deliver reliable electromagnetic shielding protection for classified information and electronic equipment across government confidential, financial data, scientific research testing and military command sectors, relying on core strengths including high-performance full-welding shielding, robust structure, fully customized design, superior corrosion resistance and comprehensive after-sales service.
Adhering to the corporate philosophy of “Technological Innovation, Quality First, Customer Centric”, KITOZER continuously invests in electromagnetic shielding R&D, optimizes production processes and upgrades product performance to meet personalized shielding demands of diverse customers with professional technology, premium products and full-cycle services.
In the future, KITOZER will deepen layout in the electromagnetic shielding industry, keep pace with emerging technologies including 5G, millimeter waves and artificial intelligence, develop higher-performance and intelligent shielding products, contribute to national information security and EMC industrial development, and help customers build safe, stable and efficient electromagnetic protection systems.
15. Search Keywords & SEO Tags
Search Keywords
- Core Keywords: Steel Plate Welded Shield Enclosure, Shielded Room, Electromagnetic Shielding Chamber, Confidential Computer Room Shielding, KITOZER Shield Enclosure
- Long-Tail Keywords: Class C Shielded Room, Military Shielding Chamber, Financial Data Center Shielding, EMC Test Chamber Shielding, Steel Plate Welded Shield Room Manufacturer, Shielded Room Solution, Electromagnetic Shield Enclosure Technical Parameters, Custom Shield Enclosure
- Regional Keywords: Guangzhou Shielded Room Manufacturer, Guangdong Steel Plate Welded Shield Enclosure, South China Confidential Computer Room Construction