Table of Contents
Toggle1. System Overview
The 4G/5G base station environmental monitoring sensor system is an integrated monitoring architecture built on the Internet of Things (IoT), intelligent sensing, edge computing and 4G/5G wireless communication technologies. Designed exclusively for base station computer rooms, outdoor base station cabinets, communication tower foundations and other scenarios, it realizes 24/7 real-time collection, transmission, analysis, early warning and remote control of environmental parameters and equipment status including temperature & humidity, water leakage, smoke, harmful gas, dust, access control, infrared intrusion, air pressure, wind speed and wind direction.
Base Station Environmental Monitoring Sensor Host
The core value of the system is to resolve pain points of traditional base stations such as low manual inspection efficiency, delayed fault detection, high operation & maintenance (O&M) costs and high risks of unattended operation. Through data-driven intelligent O&M, it ensures core base station equipment (BBU, RRU, power cabinet, storage battery, air conditioner) operates within safe and stable environmental ranges, reduces equipment failure rates and energy consumption, extends service life, supports long-term stable 4G/5G network coverage, and meets core demands of operators for cost reduction & efficiency improvement, unattended operation and intelligent O&M.
The system features industrial-grade stability, adaptability to extreme environments, low power consumption & long endurance, multi-protocol compatibility, easy deployment without wiring, customizable expansion and other characteristics. It supports dual management via local storage and remote cloud platform/monitoring center, and is compatible with NB-IoT, LoRa, 4G/5G full-network communication and other transmission modes, meeting full-scenario deployment requirements for indoor base stations, outdoor base stations, mountain base stations and densely distributed urban base stations.
2. System Composition
The system adopts a four-layer architecture: Perception Layer – Transmission Layer – Platform Layer – Application Layer. Equipment at all layers collaborates to form a closed full-link loop of “data collection – transmission – processing – application – control”.
2.1 Perception Layer (Data Collection Terminals)
System Wiring Schematic Diagram
As the “nerve endings” of the system, they are deployed inside and around base stations to collect environmental parameters and equipment status. Core devices are listed as follows:
- Temperature & Humidity Sensor: Collects temperature and relative humidity inside base stations, covering key areas such as equipment cabinets, battery compartments and corners of computer rooms.
- Water Leakage Sensor: Monitors air conditioning condensed water, pipeline leakage and ground seepage to prevent equipment soaking risks caused by ponding.
- Smoke Sensor: Detects smoke in the early stage of fire and provides advance fire warning, suitable for enclosed base station computer rooms.
- Harmful Gas Sensor: Monitors CO, SO₂, NO₂, formaldehyde and other harmful gases to prevent risks of toxic gas exceeding standard levels caused by battery leakage and equipment aging.
- Dust/PM2.5 Sensor: Collects airborne dust concentration to avoid dust accumulation impairing equipment heat dissipation and insulation performance.
- Access Control Sensor: Monitors opening/closing status of base station doors and records personnel access to guard against illegal intrusion.
- Infrared Intrusion Sensor: Detects climbing and trespassing around base stations, applicable to security scenarios of outdoor base stations.
- Air Pressure / Wind Speed & Direction Sensor: Collects air pressure, wind speed and wind direction of outdoor base stations to monitor impacts of extreme weather (typhoons, strong winds) on base station structures.
- Battery Monitoring Sensor: Collects voltage, current, temperature and internal resistance of storage batteries to monitor the status of core power supply equipment.
- Mains Power Distribution Monitoring Module: Monitors mains voltage, current, power and power-off status to guarantee power supply stability.
2.2 Transmission Layer (Data Transmission Hub)
Equipment Production Workshop
It converts protocols and encrypts raw data collected by the perception layer, and stably uploads data to the platform layer. Core equipment includes:
- 4G/5G Industrial Gateway: Supports 4G/5G full-network communication, multi-interfaces including RS485, RS232 and Ethernet, DI/DO, and protocols such as Modbus-RTU/TCP, MQTT and HTTP. It conducts edge computing for data preprocessing and adopts breakpoint resume transmission to ensure data integrity.
- Wireless DTU: Low power consumption and wide temperature design, applicable to outdoor base stations without mains power. Supports long-distance transmission via NB-IoT/LoRa to lower deployment costs.
- Signal Converter: Converts analog signals (4-20mA, 0-5V) of sensors into digital signals to support access of various sensor types.
2.3 Platform Layer (Data Processing Center)
Divided into local monitoring terminals and remote cloud platforms, it undertakes data storage, analysis, early warning and visualization. Core components:
- Local Display Terminal: Industrial touch screens and LED displays, which show real-time monitoring data and equipment status, and support local parameter configuration and alarm viewing.
- Base Station Environmental Monitoring Cloud Platform: B/S architecture, supporting centralized management of multiple base stations. Functions include data visualization (charts, curves, map positioning), historical data storage & query, alarm management (SMS, APP, phone push), remote control (air conditioner, fan, access control linkage), report export and hierarchical authority management.
- Data Storage Server: Distributed storage to secure historical data, supporting data backup and recovery, and adapting to data storage demands of large-scale base stations.
2.4 Application Layer (O&M Control Terminals)
Operation terminals oriented to O&M staff to realize anytime-anywhere monitoring and management:
- PC Management Software: Compatible with Windows systems with complete functions, suitable for centralized O&M in monitoring centers.
- Mobile APP / Mini Program: Compatible with Android and iOS systems, supporting real-time data viewing, alarm reception, remote control and work order processing for mobile O&M scenarios.
- Third-party System Docking Interface: Supports docking with existing OSS and BSS systems of operators to realize data intercommunication and adapt to integrated O&M systems.
3. System Classification
Outdoor Tower-mounted Monitoring Host
Classified by four dimensions: deployment scenario, monitoring precision, functional configuration and transmission mode, to adapt to different base station scales and O&M demands.
3.1 Classification by Deployment Scenario
- Indoor Base Station Environmental Monitoring System: Applicable to computer room base stations and integrated cabinet base stations. Focuses on monitoring temperature & humidity, water leakage, smoke, access control and battery status with protection grade above IP30.
- Outdoor Base Station Environmental Monitoring System: Applicable to outdoor cabinet base stations and communication tower foundation base stations. Focuses on monitoring temperature & humidity, dust, air pressure, wind speed & direction and infrared intrusion, with protection grade above IP65, capable of resisting high/low temperature, water, dust and electromagnetic interference.
- Mountain / Remote Base Station Environmental Monitoring System: Applicable to remote base stations without mains power and weak signals. Adopts solar power supply + low-power sensors + NB-IoT/LoRa transmission, mainly monitoring temperature & humidity, smoke, access control and battery status for long endurance and maintenance-free operation.
3.2 Classification by Monitoring Precision
- Basic Monitoring System: Meets conventional monitoring requirements. Temperature & humidity precision ±0.5℃ / ±3%RH without high-precision parameter monitoring, applicable to small and edge base stations.
- Standard Monitoring System: Mainstream precision configuration. Temperature & humidity precision ±0.3℃ / ±2%RH, supporting synchronous multi-parameter monitoring, applicable to medium-sized base stations and core urban base stations.
- High-precision Monitoring System: Research-grade precision. Temperature & humidity precision ±0.1℃ / ±1%RH, supporting high-precision monitoring of harmful gas and dust, applicable to large base stations, hub base stations and data center-level base stations.
3.3 Classification by Functional Configuration
Tower Equipment Layout Drawing
- Basic Version System: Only supports environmental parameter collection, local display and simple alarms, without remote control and cloud data storage functions, suitable for low-cost and simple O&M scenarios.
- Standard Version System: Supports parameter collection, 4G/5G remote transmission, cloud platform visualization, alarm push and historical data query without linkage control functions, applicable to mainstream O&M scenarios.
- Enhanced Version System: On the basis of the standard version, it adds equipment linkage control (automatic start/stop of air conditioners, fans, access control and exhaust fans), video monitoring integration, in-depth battery monitoring and extreme weather early warning, applicable to unattended and intelligent O&M scenarios.
- Custom Version System: Customizable monitoring parameters, transmission modes, power supply modes, linkage logic and appearance structure on demand, applicable to special scenarios requiring explosion-proof, anti-corrosion and high-temperature resistant performance.
3.4 Classification by Transmission Mode
- Wired Transmission System: Adopts RS485, Ethernet and optical fiber transmission with high stability and strong anti-interference capacity, applicable to indoor base stations and scenarios with favorable network conditions.
- Wireless Transmission System: Adopts 4G/5G, NB-IoT, LoRa and Wi-Fi transmission with wiring-free and easy deployment features, applicable to outdoor base stations, remote base stations and wiring-difficult scenarios.
- Hybrid Transmission System: Dual backup transmission of wired + wireless to guarantee uninterrupted data transmission, applicable to core base stations and key hub base stations.
Internal Circuit of Outdoor Monitoring Cabinet
4. System Schematic Diagram
plaintext
┌─────────────────────────────────────────────────────────────────┐
│ Application Layer (O&M Terminals) │
│ ┌───────────────┐ ┌───────────────┐ ┌───────────────────┐ │
│ │ PC Management │ │ Mobile APP/MP │ │ 3rd-party Docking │ │
│ │ Software │ │ Mini Program │ │ Interface │ │
│ └───────┬───────┘ └───────┬───────┘ └─────────┬─────────┘ │
└───────────┼───────────────────┼───────────────────┼───────────┘
│ │ │
┌───────────┼───────────────────┼───────────────────┼───────────┐
│ Platform Layer (Data Processing Center) │
│ ┌─────────────────────────────────────────────────────────┐ │
│ │ Base Station Env Monitoring Cloud Platform (B/S) │
│ │ ┌─────────────┐ ┌─────────────┐ ┌───────────────┐ │ │
│ │ │Data Visualization│Alarm Push│Remote Linkage Control│ │ │
│ │ └─────────────┘ └─────────────┘ └───────────────┘ │ │
│ └─────────────────────────────┬─────────────────────────┘ │
│ ┌───────────────┐ │ ┌───────────────────┐ │
│ │Local Industrial Touch Screen│◄────────────┘ │Distributed Data Storage Server│
│ └───────────────┘ └───────────────────┘ │
└─────────────────────────────────────────────────────────────────┘
│
┌───────────┼───────────────────────────────────────────────────┐
│ Transmission Layer (Data Transmission Hub) │
│ ┌─────────────────┐ ┌───────────────┐ ┌─────────────────┐ │
│ │4G/5G Industrial │ │Low-power Wireless│Signal Converter │ │
│ │Gateway(Multi-Interface/Multi-Proto)│DTU(NB-IoT/LoRa)│(Analog to Digital)│
│ └─────────┬────────┘ └────────┬────────┘ └────────┬────────┘ │
└───────────┼──────────────────────┼────────────────────┼───────────┘
│ │ │
┌───────────┼──────────────────────┼────────────────────┼───────────┐
│ Perception Layer (Data Collection Terminals) │
│ ┌───────┐ ┌───────┐ ┌───────┐ ┌───────┐ ┌───────┐ ┌───────┐ │
│ │Temp&Hum│ │Water │ │Smoke │ │Harmful│ │Dust │ │Access │ │
│ │Sensor │ │Leakage│ │Sensor │ │Gas │ │Sensor │ │Ctrl │ │
│ └───────┘ └───────┘ └───────┘ └───────┘ └───────┘ └───────┘ │
│ ┌───────┐ ┌───────┐ ┌───────┐ ┌───────┐ ┌───────┐ │
│ │Infrared│ │Air │ │Wind Sp&│ │Battery│ │Mains │ │
│ │Intrusion│ │Pressure│Dir Sensor│Monitor│ │Monitor│ │
│ └───────┘ └───────┘ └───────┘ └───────┘ └───────┘ │
└─────────────────────────────────────────────────────────────────┘
5. Full System Configuration List (3 Grades: Low / Medium / High, Brand: KITOZER)
Command Center Platform Dashboard
5.1 Low-Grade Configuration List (Basic Type, for Small / Edge Base Stations)
| Serial No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Temperature & Humidity Sensor | KTR-TH100 | Temp: -40℃~60℃, precision ±0.5℃; Humidity: 0~100%RH, precision ±3%RH; Output: RS485; Power Supply: 12VDC; Protection: IP30 | 1 | Set | KITOZER | Indoor Wall-mounted |
| 2 | Water Leakage Sensor | KTR-WL200 | Detection: Electrode type; Induction Distance: 0~5mm; Output: Switch Signal; Power Supply:12VDC; Protection:IP65 | 1 | Set | KITOZER | Ground-mounted |
| 3 | Smoke Sensor | KTR-SM300 | Detection: Photoelectric; Sensitivity:0.15~0.31dB/m; Output:Switch Signal; Power Supply:12VDC; Protection:IP30 | 1 | Set | KITOZER | Ceiling-mounted |
| 4 | Access Control Sensor | KTR-MG400 | Detection: Magnetic Control; Response Time: ≤1s; Output: Passive Switch; Protection:IP54 | 1 | Set | KITOZER | Base station door mounted |
| 5 | 4G Industrial Gateway | KTR-GW500 | Comm:4G Full-network; Interfaces:1×RS485,1×Ethernet; Protocol:Modbus-RTU, MQTT; Power Supply:12VDC; Protection:IP30; Working Temp:-10℃~60℃ | 1 | Set | KITOZER | Cabinet-mounted |
| 6 | Local Display Terminal | KTR-DP600 | Screen:4.3-inch LED; Display: Real-time Temp&Humidity, Alarm Status; Operation: Key Setting; Power Supply:12VDC; Protection:IP30 | 1 | Set | KITOZER | Wall-mounted |
| 7 | Power Adapter | KTR-PW700 | Input:AC100~240V; Output:DC12V/2A; Protection:IP30, Overvoltage/Overcurrent Protection | 1 | Pc | KITOZER | Supporting power supply |
5.2 Medium-Grade Configuration List (Standard Type, for Medium-sized / Core Urban Base Stations)
| Serial No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Temperature & Humidity Sensor | KTR-TH101 | Temp:-40℃~85℃, precision ±0.3℃; Humidity:0~100%RH, precision ±2%RH; Output:RS485/4-20mA; Power Supply:12~24VDC; Protection:IP65 | 2 | Set | KITOZER | 1 indoor,1 cabinet inner |
| 2 | Water Leakage Sensor | KTR-WL201 | Detection:Cable type; Induction Length:5m (customizable); Output:RS485; Power Supply:12VDC; Protection:IP67, Acid & Alkali Resistant | 1 | Set | KITOZER | Laid on computer room floor |
| 3 | Smoke Sensor | KTR-SM301 | Detection: Photoelectric + Ion Composite; Sensitivity:0.1~0.5dB/m; Output:RS485/Switch Signal; Power Supply:12VDC; Protection:IP54 | 1 | Set | KITOZER | Ceiling-mounted |
| 4 | CO Harmful Gas Sensor | KTR-GS401 | Detect Gas:CO; Range:0~1000ppm; Precision:±5%FS; Output:RS485/4-20mA; Power Supply:12~24VDC; Protection:IP65 | 1 | Set | KITOZER | Installed in battery compartment |
| 5 | PM2.5 Dust Sensor | KTR-DS501 | Detect Particle:PM2.5; Range:0~1000μg/m³; Precision:±10%FS; Output:RS485; Power Supply:12VDC; Protection:IP54 | 1 | Set | KITOZER | Installed in middle of computer room |
| 6 | Access Control Sensor | KTR-MG401 | Detection:Magnetic Control; Response Time:≤0.5s; Output:RS485/Switch Signal; Power Supply:12VDC; Protection:IP65, Tamper Alarm | 1 | Set | KITOZER | Base station door mounted |
| 7 | Infrared Intrusion Sensor | KTR-IR601 | Detection Distance:10m; Detection Angle:120°; Output:Switch Signal; Power Supply:12VDC; Protection:IP65, Anti Strong Light Interference | 2 | Set | KITOZER | Installed on both sides of outdoor base station |
| 8 | Battery Monitoring Module | KTR-BM701 | Monitor:Voltage, Current, Temp; Range:0~60V Voltage,0~100A Current; Precision:±0.5%FS; Output:RS485; Power Supply:12VDC; Protection:IP54 | 1 | Set | KITOZER | Supporting battery pack |
| 9 | 5G Industrial Gateway | KTR-GW501 | Comm:5G/4G Full-network; Interfaces:2×RS485,1×RS232,1×Ethernet,4×DI/2×DO; Protocol:Modbus-RTU/TCP, MQTT, HTTP; Power Supply:12~24VDC; Protection:IP40; Working Temp:-20℃~70℃, Edge Computing Supported | 1 | Set | KITOZER | Cabinet-mounted |
| 10 | Industrial Touch Screen | KTR-DP601 | Screen:7-inch Industrial Touch; Display: Multi-parameter Real-time Data, Curve, Alarm; Operation: Touch + Key; Power Supply:12VDC; Protection:IP54, Local Data Storage | 1 | Set | KITOZER | Wall-mounted |
| 11 | Power Adapter | KTR-PW701 | Input:AC100~240V; Output:DC12V/5A; Protection:IP40, Overvoltage/Overcurrent/Short Circuit Protection | 1 | Pc | KITOZER | Supporting power supply |
| 12 | Installation Auxiliary Materials | / | Sensor Bracket, RS485 Communication Cable, Power Cable, Waterproof Connector, Cable Tie | 1 | Batch | KITOZER | Supporting installation |
5.3 High-Grade Configuration List (High-precision / Enhanced Type, for Large / Hub Base Stations)
| Serial No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | High-precision Temp & Humidity Sensor | KTR-TH102 | Temp:-55℃~125℃, precision ±0.1℃; Humidity:0~100%RH, precision ±1%RH; Output:RS485/4-20mA/0-5V; Power Supply:12~24VDC; Protection:IP67, Annual Drift ≤0.1% | 3 | Set | KITOZER | 1 indoor,1 cabinet,1 battery compartment |
| 2 | High-precision Water Leakage Sensor | KTR-WL202 | Detection:Optical + Cable Composite; Induction Length:10m (customizable); Output:RS485/Switch Signal; Power Supply:12~24VDC; Protection:IP68, Corrosion & Temp Resistant | 2 | Set | KITOZER | 1 for floor,1 for air conditioning zone |
| 3 | Composite Smoke Sensor | KTR-SM302 | Detection:Photoelectric + Ion + Temp Composite; Sensitivity:0.05~0.6dB/m; Output:RS485/Switch Signal; Power Supply:12~24VDC; Protection:IP65, Fire Location Early Warning | 2 | Set | KITOZER | 1 ceiling,1 equipment zone |
| 4 | Multi-parameter Harmful Gas Sensor | KTR-GS402 | Detect:CO, SO₂, NO₂, Formaldehyde; Range:CO 0~1000ppm, SO₂ 0~200ppm; Precision:±3%FS; Output:RS485/4-20mA; Power Supply:12~24VDC; Protection:IP67, All-in-one Multi-parameter | 1 | Set | KITOZER | Battery compartment mounted |
| 5 | PM2.5/PM10 Dust Sensor | KTR-DS502 | Detect:PM2.5, PM10; Range:0~1000μg/m³; Precision:±5%FS; Output:RS485; Power Supply:12~24VDC; Protection:IP65, Dual Parameter Simultaneous Monitoring | 1 | Set | KITOZER | Middle of computer room |
| 6 | Air Pressure Sensor | KTR-PS802 | Range:300~1100hPa; Precision:±0.5hPa; Output:RS485/4-20mA; Power Supply:12VDC; Protection:IP65 | 1 | Set | KITOZER | Outdoor cabinet mounted |
| 7 | Wind Speed & Direction Sensor | KTR-WS902 | Wind Speed:0~60m/s, precision ±0.3m/s; Wind Direction:0~360°, precision ±2°; Output:RS485; Power Supply:12~24VDC; Protection:IP67, Ultrasonic Design Without Mechanical Wear | 1 | Set | KITOZER | Installed on top of communication tower |
| 8 | Intelligent Access Control Sensor | KTR-MG402 | Detection:Magnetic Control + Card Swipe Composite; Response Time:≤0.3s; Output:RS485/Switch Signal; Power Supply:12VDC; Protection:IP65, Store 20,000 Access Records, Remote Authorization | 1 | Set | KITOZER | Base station door mounted |
| 9 | High-definition Infrared Intrusion Sensor | KTR-IR602 | Detection Distance:15m; Detection Angle:180°; Output:RS485/Switch Signal; Power Supply:12VDC; Protection:IP67, Anti-pet Interference, Intelligent Identification | 4 | Set | KITOZER | Installed around outdoor base station |
| 10 | In-depth Battery Monitoring Module | KTR-BM702 | Monitor:Voltage, Current, Temp, Internal Resistance, SOC; Range:0~100V Voltage,0~200A Current; Precision:±0.2%FS; Output:RS485; Power Supply:12VDC; Protection:IP65, Fault Early Warning, Service Life Evaluation | 1 | Set | KITOZER | Supporting battery pack |
| 11 | Mains Power Distribution Monitoring Module | KTR-PM1002 | Monitor:Voltage, Current, Power, Frequency, Power-off Status; Range:0~380V Voltage,0~500A Current; Precision:±0.5%FS; Output:RS485; Power Supply:AC220V; Protection:IP54, Phase Loss / Overload Alarm | 1 | Set | KITOZER | Installed in power distribution cabinet |
| 12 | Enhanced 5G Industrial Gateway | KTR-GW502 | Comm:5G/4G Full-network, Wi-Fi, Bluetooth; Interfaces:4×RS485,2×RS232,2×Ethernet,8×DI/4×DO,1×HDMI; Protocol:Modbus-RTU/TCP, MQTT, HTTP, OPC UA; Power Supply:12~24VDC; Protection:IP40; Working Temp:-30℃~80℃, Edge Computing, Data Encryption, Breakpoint Resume | 1 | Set | KITOZER | Cabinet-mounted |
| 13 | High-definition Industrial Touch Screen | KTR-DP602 | Screen:10.1-inch HD Touch; Display: Multi-parameter Data, Curve, Chart, Alarm, Video Integration; Operation: Touch + Key + Remote Control; Power Supply:12~24VDC; Protection:IP65, Local 1-year Data Storage & Export | 1 | Set | KITOZER | Wall-mounted |
| 14 | Solar Power Supply System | KTR-SP1102 | Solar Panel:100W Monocrystalline Silicon; Battery:12V/50Ah Lead-acid Maintenance-free; Controller:MPPT Charging; Output:DC12V/5A; Protection:IP65, 7-day Endurance on Rainy Days | 1 | Set | KITOZER | Supporting outdoor base station |
| 15 | Power Adapter | KTR-PW702 | Input:AC100~240V; Output:DC12V/10A; Protection:IP40, Overvoltage/Overcurrent/Short Circuit/Lightning Protection | 1 | Pc | KITOZER | Indoor equipment power supply |
| 16 | Installation Auxiliary Materials | / | Sensor Bracket, Shielded RS485 Cable, Shielded Power Cable, Waterproof Connector, Lightning Arrester, Cable Tie, Wire Groove | 1 | Batch | KITOZER | Supporting installation |
6. Full Product Technical Parameters
Roof Tower-mounted Monitoring Host
6.1 Temperature & Humidity Sensor
- KTR-TH100 (Low Grade): Temp Range -40℃~60℃, Precision ±0.5℃; Humidity Range 0~100%RH, Precision ±3%RH; Output RS485; Power Supply 12VDC; Power Consumption ≤0.5W; Response Time ≤10s; Protection IP30; Working Temp -10℃~60℃.
- KTR-TH101 (Medium Grade): Temp Range -40℃~85℃, Precision ±0.3℃; Humidity Range 0~100%RH, Precision ±2%RH; Output RS485/4-20mA; Power Supply 12~24VDC; Power Consumption ≤0.8W; Response Time ≤5s; Protection IP65; Working Temp -20℃~70℃.
- KTR-TH102 (High Grade): Temp Range -55℃~125℃, Precision ±0.1℃; Humidity Range 0~100%RH, Precision ±1%RH; Output RS485/4-20mA/0-5V; Power Supply 12~24VDC; Power Consumption ≤1W; Response Time ≤2s; Protection IP67; Annual Drift ≤0.1%; Working Temp -30℃~80℃.
6.2 Water Leakage Sensor
- KTR-WL200 (Low Grade): Electrode Detection; Induction Distance 0~5mm; Output Switch Signal; Power Supply 12VDC; Power Consumption ≤0.3W; Response Time ≤1s; Protection IP65; Working Temp -10℃~60℃.
- KTR-WL201 (Medium Grade): Cable Detection; Customizable 5m Induction Cable; Output RS485; Power Supply 12VDC; Power Consumption ≤0.5W; Response Time ≤0.5s; Protection IP67, Acid & Alkali Resistant; Working Temp -20℃~70℃.
- KTR-WL202 (High Grade): Optical + Cable Composite Detection; Customizable 10m Induction Cable; Output RS485/Switch Signal; Power Supply 12~24VDC; Power Consumption ≤0.8W; Response Time ≤0.3s; Protection IP68, Corrosion & Extreme Temp Resistant; Working Temp -30℃~80℃.
6.3 Smoke Sensor
Outdoor Monitoring Host Close-up
- KTR-SM300 (Low Grade): Photoelectric Detection; Sensitivity 0.15~0.31dB/m; Output Switch Signal; Power Supply 12VDC; Power Consumption ≤0.4W; Response Time ≤3s; Protection IP30; Working Temp -10℃~60℃.
- KTR-SM301 (Medium Grade): Photoelectric + Ion Composite Detection; Sensitivity 0.1~0.5dB/m; Output RS485/Switch Signal; Power Supply 12VDC; Power Consumption ≤0.6W; Response Time ≤2s; Protection IP54; Working Temp -20℃~70℃.
- KTR-SM302 (High Grade): Photoelectric + Ion + Temp Composite Detection; Sensitivity 0.05~0.6dB/m; Output RS485/Switch Signal; Power Supply 12~24VDC; Power Consumption ≤0.9W; Response Time ≤1s; Protection IP65, Fire Location Early Warning; Working Temp -30℃~80℃.
6.4 Harmful Gas Sensor
- KTR-GS401 (Medium Grade, CO Only): Detects CO; Range 0~1000ppm; Precision ±5%FS; Output RS485/4-20mA; Power Supply 12~24VDC; Power Consumption ≤1W; Response Time ≤30s; Protection IP65; Working Temp -20℃~70℃.
- KTR-GS402 (High Grade, Multi-gas): Detects CO, SO₂, NO₂, Formaldehyde; CO Range 0~1000ppm, SO₂ Range 0~200ppm, NO₂ Range 0~200ppm, Formaldehyde Range 0~10ppm; Precision ±3%FS; Output RS485/4-20mA; Power Supply 12~24VDC; Power Consumption ≤1.5W; Response Time ≤20s; Protection IP67; Working Temp -30℃~80℃.
6.5 Dust Sensor
- KTR-DS501 (Medium Grade, PM2.5 Only): Detects PM2.5; Range 0~1000μg/m³; Precision ±10%FS; Output RS485; Power Supply 12VDC; Power Consumption ≤0.8W; Response Time ≤90s; Protection IP54; Working Temp -20℃~70℃.
- KTR-DS502 (High Grade, PM2.5 + PM10): Detects PM2.5 & PM10; Range 0~1000μg/m³; Precision ±5%FS; Output RS485; Power Supply 12~24VDC; Power Consumption ≤1W; Response Time ≤60s; Protection IP65; Working Temp -30℃~80℃.
6.6 Access Control Sensor
Tower Monitoring Host with Camera
- KTR-MG400 (Low Grade): Magnetic Control Detection; Response Time ≤1s; Passive Switch Output; Protection IP54; Working Temp -10℃~60℃.
- KTR-MG401 (Medium Grade): Magnetic Control Detection; Response Time ≤0.5s; RS485/Switch Output; Power Supply 12VDC; Power Consumption ≤0.3W; Protection IP65, Tamper Alarm; Working Temp -20℃~70℃.
- KTR-MG402 (High Grade): Magnetic Control + Card Swipe Composite Detection; Response Time ≤0.3s; RS485/Switch Output; Power Supply 12VDC; Power Consumption ≤0.5W; Protection IP65, Store 20,000 Access Records & Remote Authorization; Working Temp -30℃~80℃.
6.7 Infrared Intrusion Sensor
- KTR-IR601 (Medium Grade): Detection Distance 10m; Detection Angle 120°; Switch Signal Output; Power Supply 12VDC; Power Consumption ≤0.4W; Protection IP65, Anti Strong Light Interference; Working Temp -20℃~70℃.
- KTR-IR602 (High Grade): Detection Distance 15m; Detection Angle 180°; RS485/Switch Output; Power Supply 12VDC; Power Consumption ≤0.6W; Protection IP67, Anti-pet Interference & Intelligent Identification; Working Temp -30℃~80℃.
6.8 Air Pressure Sensor (High Grade Only)
Model KTR-PS802; Range 300~1100hPa; Precision ±0.5hPa; Resolution 0.1hPa; Output RS485/4-20mA; Power Supply 12VDC; Power Consumption ≤0.5W; Protection IP65; Working Temp -30℃~80℃.
6.9 Wind Speed & Direction Sensor (High Grade Only)
Model KTR-WS902; Wind Speed 0~60m/s, Precision ±0.3m/s, Resolution 0.05m/s; Wind Direction 0~360°, Precision ±2°, Resolution 1°; Output RS485; Power Supply 12~24VDC; Power Consumption ≤0.8W; Protection IP67; Ultrasonic design without mechanical wear; Working Temp -30℃~80℃.
6.10 Battery Monitoring Module
- KTR-BM701 (Medium Grade): Monitors Voltage, Current, Temperature; Voltage Range 0~60V, Current Range 0~100A; Precision ±0.5%FS; Output RS485; Power Supply 12VDC; Power Consumption ≤0.8W; Protection IP54; Working Temp -20℃~70℃.
- KTR-BM702 (High Grade): Monitors Voltage, Current, Temperature, Internal Resistance, SOC; Voltage Range 0~100V, Current Range 0~200A; Precision ±0.2%FS; Output RS485; Power Supply 12VDC; Power Consumption ≤1W; Protection IP65, Fault Early Warning & Service Life Evaluation; Working Temp -30℃~80℃.
6.11 Mains Power Distribution Monitoring Module (High Grade Only)
Model KTR-PM1002; Monitors Voltage, Current, Power, Frequency, Power-off Status; Voltage Range 0~380V, Current Range 0~500A; Precision ±0.5%FS; Output RS485; Power Supply AC220V; Power Consumption ≤1.5W; Protection IP54, Phase Loss / Overload Alarm; Working Temp -20℃~70℃.
6.12 Industrial Gateway
- KTR-GW500 (Low Grade, 4G): 4G Full-network Communication; Interfaces 1×RS485,1×Ethernet; Protocols Modbus-RTU, MQTT; Power Supply 12VDC; Power Consumption ≤1W; Protection IP30; Working Temp -10℃~60℃.
- KTR-GW501 (Medium Grade, 5G): 5G/4G Full-network Communication; Interfaces 2×RS485,1×RS232,1×Ethernet,4×DI/2×DO; Protocols Modbus-RTU/TCP, MQTT, HTTP; Power Supply 12~24VDC; Power Consumption ≤2W; Protection IP40; Working Temp -20℃~70℃, Edge Computing Supported.
- KTR-GW502 (High Grade, Enhanced 5G): 5G/4G Full-network + Wi-Fi + Bluetooth; Interfaces 4×RS485,2×RS232,2×Ethernet,8×DI/4×DO,1×HDMI; Protocols Modbus-RTU/TCP, MQTT, HTTP, OPC UA; Power Supply 12~24VDC; Power Consumption ≤3W; Protection IP40; Working Temp -30℃~80℃, Edge Computing, Data Encryption & Breakpoint Resume Supported.
6.13 Industrial Touch Screen
- KTR-DP600 (Low Grade): 4.3-inch LED Screen; Displays Real-time Temp&Humidity & Alarm Status; Key Operation; Power Supply 12VDC; Power Consumption ≤1W; Protection IP30; Working Temp -10℃~60℃.
- KTR-DP601 (Medium Grade): 7-inch Industrial Touch Screen; Displays Multi-parameter Data, Curves & Alarms; Touch + Key Operation; Power Supply 12VDC; Power Consumption ≤1.5W; Protection IP54, Local Data Storage; Working Temp -20℃~70℃.
- KTR-DP602 (High Grade): 10.1-inch HD Touch Screen; Displays Multi-parameter Data, Curves, Charts, Alarms & Video Integration; Touch + Key + Remote Control; Power Supply 12~24VDC; Power Consumption ≤2W; Protection IP65, 1-year Local Data Storage & Export; Working Temp -30℃~80℃.
6.14 Solar Power Supply System (High Grade Only)
Model KTR-SP1102; 100W Monocrystalline Silicon Solar Panel; 12V/50Ah Maintenance-free Lead-acid Battery; MPPT Charging Controller (Efficiency ≥95%); Output DC12V/5A; Protection IP65, 7-day Endurance on Rainy Days; Working Temp -30℃~80℃.
6.15 Power Adapter
- KTR-PW700 (Low Grade): Input AC100~240V; Output DC12V/2A; Power Consumption ≤0.5W; Protection IP30, Overvoltage/Overcurrent Protection; Working Temp -10℃~60℃.
- KTR-PW701 (Medium Grade): Input AC100~240V; Output DC12V/5A; Power Consumption ≤1W; Protection IP40, Overvoltage/Overcurrent/Short Circuit Protection; Working Temp -20℃~70℃.
- KTR-PW702 (High Grade): Input AC100~240V; Output DC12V/10A; Power Consumption ≤1.5W; Protection IP40, Overvoltage/Overcurrent/Short Circuit/Lightning Protection; Working Temp -30℃~80℃.
7. Full Product Application Scope
7.1 Temperature & Humidity Sensor
- Temperature & humidity monitoring for 4G/5G base station computer rooms, integrated cabinets, battery compartments and inner equipment cabinets.
- Environmental temp & humidity monitoring for outdoor base station cabinets and communication tower equipment compartments.
- Temp & humidity monitoring for supporting warehouses, duty rooms and power distribution rooms of base stations.
7.2 Water Leakage Sensor
- Leakage monitoring on computer room floors, air conditioning condensate drains and pipeline joints of base stations.
- Seepage monitoring at the bottom of battery compartments and power distribution cabinets.
- Ponding monitoring at the bottom of outdoor base station cabinets and communication tower foundations.
7.3 Smoke Sensor
- Smoke monitoring for ceilings, equipment zones and battery compartments of base station computer rooms to prevent fire hazards.
- Smoke monitoring inside outdoor base station cabinets and power compartments.
- Smoke monitoring for supporting power distribution rooms and generator rooms of base stations.
7.4 Harmful Gas Sensor
- Monitoring CO and sulfuric acid mist in battery compartments to warn against battery leakage risks.
- Monitoring SO₂, NO₂, formaldehyde and other harmful gases in computer rooms and power distribution rooms caused by equipment aging and decoration pollution.
- Monitoring accumulation of harmful gases inside outdoor base station cabinets.
7.5 Dust Sensor
- Dust concentration monitoring inside computer rooms and equipment cabinets to avoid heat dissipation and insulation failures caused by dust accumulation.
- Dust monitoring inside outdoor base station cabinets and communication tower equipment compartments in windy & sandy environments.
- Dust monitoring for supporting warehouses and duty rooms of base stations.
7.6 Access Control Sensor
- Monitoring opening/closing status of computer room doors, outdoor cabinet doors and power distribution room doors, and recording personnel access records.
- Early warning against unauthorized opening of key equipment cabinets and battery compartment doors of base stations.
7.7 Infrared Intrusion Sensor
- Security monitoring against climbing and trespassing around outdoor base stations and tower foundations.
- Intrusion monitoring for windows and vents of base station computer rooms.
- Security monitoring around supporting warehouses and power distribution rooms of base stations.
7.8 Air Pressure / Wind Speed & Direction Sensor
- Monitoring air pressure, wind speed and wind direction of outdoor base stations and tower foundations to provide early warning of extreme weather such as typhoons and strong winds, preventing tower tilt and equipment damage.
- Meteorological environment monitoring for mountain and coastal base stations adapting to complex climate scenarios.
7.9 Battery Monitoring Module
- Real-time monitoring of voltage, current, temperature, internal resistance and SOC of lead-acid/lithium battery packs for 4G/5G base stations, supporting power status monitoring, fault early warning and service life evaluation.
- Monitoring backup power supply systems and UPS battery packs of base stations.
7.10 Mains Power Distribution Monitoring Module
- Monitoring voltage, current, power, frequency and power-off status of mains input, power distribution cabinets and UPS front ends of base stations, providing early warning for unstable power supply, phase loss and overload.
- Power distribution system monitoring for computer rooms and outdoor base station cabinets.
7.11 Industrial Gateway
- Data collection, protocol conversion and 4G/5G wireless transmission for all base station sensors and monitoring equipment, uploading data to cloud platforms/monitoring centers.
- Communication hub between local base station equipment and remote platforms, supporting edge computing and data preprocessing with breakpoint resume transmission.
7.12 Industrial Touch Screen
- Local real-time display of monitoring data, equipment status viewing, alarm prompt, local parameter configuration and operation for base stations.
- Local monitoring terminals installed in computer rooms and duty rooms, meeting local viewing demands for unattended scenarios.
7.13 Solar Power Supply System
- Power supply for sensors, gateways and touch screens at mountain, remote and off-grid base stations, providing stable DC12V power with long endurance and maintenance-free operation.
- Emergency power supply and backup power supplement for outdoor base stations.
8. Full Product Advantages
8.1 General Advantages of All Series Products
- Strong Customization Capacity: Customizable monitoring parameters, measuring ranges, precision, output signals, power supply modes, appearance and installation methods to meet special base station scenario demands. Custom explosion-proof, anti-corrosion, high/low temperature resistant specifications are available for extreme environment deployment.
- OEM/ODM Service Support: Brand labeling, customized R&D and mass production are available to meet branding demands of operators and system integrators.
- Strict Confidentiality Mechanism: Signed non-disclosure agreements protect customized solutions, technical parameters, drawings and production processes to safeguard client intellectual property and commercial secrets.
- In-stock Supply: All regular models are in stock for delivery within 48 hours after order placement, shortening project delivery cycles and supporting rapid deployment & emergency reconstruction of base stations.
- Industrial-grade Quality: All products adopt industrial-grade electronic components and pass strict tests of high/low temperature, humidity, vibration and electromagnetic interference, delivering high stability and reliability for 24/7 continuous operation of base stations.
- Extreme Environment Adaptability: Wide temperature range (-30℃~80℃), IP30~IP68 waterproof & dustproof rating, anti-electromagnetic interference, resistant to high/low temperature, corrosion and aging, suitable for complex base station environments including indoor, outdoor, mountain and coastal areas with sandstorms.
- Low Power Consumption & Long Endurance: Low-power design for sensors and gateways supports solar power supply for off-grid remote base stations to reduce O&M costs.
- Easy Wiring-free Deployment: Wireless transmission via 4G/5G, NB-IoT and LoRa simplifies construction and shortens deployment cycles, suitable for reconstruction of existing base stations.
- High Compatibility: Supports multi-interfaces including RS485, RS232, Ethernet, 4-20mA and 0-5V, compatible with multi-protocols Modbus-RTU/TCP, MQTT and HTTP, capable of docking mainstream sensors, gateways, cloud platforms and third-party systems on the market.
8.2 Exclusive Advantages of Each Product
- Temperature & Humidity Sensor: Ultra-high precision (±0.1℃ / ±1%RH), fast response (≤2s), minimal annual drift (≤0.1%) and stable long-term operation; multiple optional output signals compatible with various collection equipment.
- Water Leakage Sensor: Multiple detection modes (electrode / cable / optical composite), high induction sensitivity, fast response, top-grade IP68 protection, resistant to corrosion, acid, alkali and extreme temperature, suitable for highly humid and ponding-prone scenarios.
- Smoke Sensor: Composite detection (photoelectric + ion + temperature), high sensitivity with low false alarm rate, capable of fire zone positioning and advance fire warning to secure base station equipment.
- Harmful Gas Sensor: All-in-one multi-parameter detection (CO, SO₂, NO₂, formaldehyde), high precision and resolution with fast response to real-time gas concentration monitoring, preventing risks of battery leakage and equipment aging.
- Dust Sensor: Dual PM2.5/PM10 detection, high precision and strong anti-interference performance for real-time dust monitoring to protect equipment heat dissipation and insulation performance.
- Access Control Sensor: Magnetic control + card swipe composite design, fast response, tamper alarm, access record storage and remote authorization to guarantee access security of base stations.
- Infrared Intrusion Sensor: Long detection distance & wide angle, anti-pet interference and intelligent identification, anti-strong light interference and high protection grade for outdoor base station security scenarios.
- Wind Speed & Direction Sensor: Ultrasonic design without mechanical wear and long service life, high precision and resolution for real-time meteorological parameter monitoring to warn against extreme weather impacts on base stations.
- Battery Monitoring Module: In-depth monitoring of voltage, current, temperature, internal resistance and SOC with high precision, supporting fault early warning and service life evaluation to extend battery service life and reduce replacement costs.
- Mains Power Distribution Monitoring Module: Multi-parameter monitoring of voltage, current, power, frequency and power-off with high precision, providing early warning for phase loss, overload and power cut to guarantee stable power supply of base stations.
- Industrial Gateway: Rich multi-interfaces and multi-protocol compatibility, high-speed 5G transmission, powerful edge computing, data encryption and breakpoint resume transmission for stable and secure data transmission & remote O&M.
- Industrial Touch Screen: HD touch screen with abundant display content, supporting local operation and remote control, long-term local data storage for local monitoring demands of unattended base stations.
- Solar Power Supply System: High conversion efficiency solar panels, large-capacity batteries and MPPT charging controllers with long 7-day rainy-day endurance, green and maintenance-free for off-grid remote base stations.
9. Bid-winning Controllable Parameters of All Products (Marked with *)
9.1 Temperature & Humidity Sensor
- *Temperature Range: -55℃~125℃ (High Grade) / -40℃~85℃ (Medium Grade) / -40℃~60℃ (Low Grade)
- *Temperature Precision: ±0.1℃ (High Grade) / ±0.3℃ (Medium Grade) / ±0.5℃ (Low Grade)
- *Humidity Precision: ±1%RH (High Grade) / ±2%RH (Medium Grade) / ±3%RH (Low Grade)
- *Output Signal: RS485/4-20mA/0-5V (High Grade), RS485/4-20mA (Medium Grade), RS485 (Low Grade)
- *Protection Grade: IP67 (High Grade) / IP65 (Medium Grade) / IP30 (Low Grade)
- *Working Temperature: -30℃~80℃ (High Grade) / -20℃~70℃ (Medium Grade) / -10℃~60℃ (Low Grade)
9.2 Water Leakage Sensor
- *Detection Mode: Optical + Cable Composite (High Grade), Cable Type (Medium Grade), Electrode Type (Low Grade)
- *Induction Length: 10m (High Grade) / 5m (Medium Grade) / 0~5mm (Low Grade)
- *Output Signal: RS485/Switch Signal (High Grade), RS485 (Medium Grade), Switch Signal (Low Grade)
- *Protection Grade: IP68 (High Grade) / IP67 (Medium Grade) / IP65 (Low Grade)
9.3 Smoke Sensor
- *Detection Type: Photoelectric + Ion + Temp Composite (High Grade), Photoelectric + Ion Composite (Medium Grade), Photoelectric Only (Low Grade)
- *Sensitivity: 0.05~0.6dB/m (High Grade) / 0.1~0.5dB/m (Medium Grade) / 0.15~0.31dB/m (Low Grade)
- *Output Signal: RS485/Switch Signal (High & Medium Grade), Switch Signal (Low Grade)
- *Protection Grade: IP65 (High Grade) / IP54 (Medium Grade) / IP30 (Low Grade)
9.4 Harmful Gas Sensor
- *Detectable Gases: CO, SO₂, NO₂, Formaldehyde (High Grade), CO Only (Medium Grade)
- *Measuring Range: CO 0~1000ppm, SO₂ 0~200ppm (High Grade), CO 0~1000ppm (Medium Grade)
- *Precision: ±3%FS (High Grade) / ±5%FS (Medium Grade)
- *Output Signal: RS485/4-20mA (High & Medium Grade)
- *Protection Grade: IP67 (High Grade) / IP65 (Medium Grade)
9.5 Dust Sensor
- *Detectable Particles: PM2.5 + PM10 (High Grade), PM2.5 Only (Medium Grade)
- *Measuring Range: 0~1000μg/m³ (High & Medium Grade)
- *Precision: ±5%FS (High Grade) / ±10%FS (Medium Grade)
- *Protection Grade: IP65 (High Grade) / IP54 (Medium Grade)
9.6 Access Control Sensor
- *Detection Mode: Magnetic Control + Card Swipe Composite (High Grade), Magnetic Control Only (Medium & Low Grade)
- *Response Time: ≤0.3s (High Grade) / ≤0.5s (Medium Grade) / ≤1s (Low Grade)
- *Output Signal: RS485/Switch Signal (High & Medium Grade), Switch Signal (Low Grade)
- *Protection Grade: IP65 (High & Medium Grade) / IP54 (Low Grade)
9.7 Infrared Intrusion Sensor
- *Detection Distance: 15m (High Grade) / 10m (Medium Grade)
- *Detection Angle: 180° (High Grade) / 120° (Medium Grade)
- *Output Signal: RS485/Switch Signal (High Grade), Switch Signal (Medium Grade)
- *Protection Grade: IP67 (High Grade) / IP65 (Medium Grade)
9.8 Wind Speed & Direction Sensor (High Grade Only)
- *Wind Speed Range: 0~60m/s
- *Wind Speed Precision: ±0.3m/s
- *Wind Direction Precision: ±2°
- *Protection Grade: IP67
9.9 Battery Monitoring Module
- *Monitored Parameters: Voltage, Current, Temp, Internal Resistance, SOC (High Grade), Voltage, Current, Temp Only (Medium Grade)
- *Voltage Measuring Range: 0~100V (High Grade) / 0~60V (Medium Grade)
- *Precision: ±0.2%FS (High Grade) / ±0.5%FS (Medium Grade)
- *Protection Grade: IP65 (High Grade) / IP54 (Medium Grade)
9.10 Industrial Gateway
- *Communication Mode: 5G/4G Full-network + Wi-Fi + Bluetooth (High Grade), 5G/4G Full-network Only (Medium Grade), 4G Full-network Only (Low Grade)
- *Interface Quantity: 4×RS485 + 2×RS232 + 2×Ethernet (High Grade), 2×RS485 +1×RS232 +1×Ethernet (Medium Grade), 1×RS485 +1×Ethernet (Low Grade)
- *Supported Protocols: Modbus-RTU/TCP, MQTT, HTTP, OPC UA (High Grade), Modbus-RTU/TCP, MQTT, HTTP (Medium Grade), Modbus-RTU, MQTT (Low Grade)
- *Protection Grade: IP40 (High & Medium Grade) / IP30 (Low Grade)
- *Working Temperature: -30℃~80℃ (High Grade) / -20℃~70℃ (Medium Grade) / -10℃~60℃ (Low Grade)
9.11 Industrial Touch Screen
- *Screen Size: 10.1-inch (High Grade) /7-inch (Medium Grade) /4.3-inch (Low Grade)
- *Display Function: Video Integration + Multi-parameter Charts (High Grade), Multi-parameter Curves + Alarms (Medium Grade), Temp&Humidity + Alarms Only (Low Grade)
- *Protection Grade: IP65 (High Grade) / IP54 (Medium Grade) / IP30 (Low Grade)
9.12 Solar Power Supply System (High Grade Only)
- *Solar Panel Power: 100W
- *Battery Capacity: 12V/50Ah
- *Charging Controller Efficiency: ≥95%
- *Rainy-day Endurance: ≥7 Days
10. Complete Product Solutions
10.1 Indoor Base Station Environmental Monitoring Solution
10.1.1 Demand Pain Points
Indoor base station computer rooms feature enclosed space and dense equipment, prone to excessive temperature & humidity, water leakage, fire hazards, difficult personnel access management and challenges in battery status monitoring. Traditional manual inspection has low efficiency and delayed fault detection, impairing stable base station operation.
10.1.2 Solution Design
Adopt Medium-Grade System (Low-Grade for small indoor base stations, High-Grade for large hub base stations). Deploy temperature & humidity sensors (computer room + inner cabinets), water leakage sensors (floor + air conditioning zone), smoke sensors (ceiling + equipment zone), CO harmful gas sensors (battery compartment), dust sensors (middle of computer room) and access control sensors (computer room door), equipped with battery monitoring modules. Connect to cloud platform via 5G industrial gateway and deploy local industrial touch screens to realize full-parameter real-time monitoring, remote transmission, alarm push, local display and operation of temperature & humidity, water leakage, smoke, harmful gas, dust, access control and battery status.
10.1.3 Solution Advantages
- Full parameter coverage: Covers core environmental parameters and power equipment status of indoor base stations without monitoring blind spots.
- Precision early warning: Timely alarms for smoke, water leakage and excessive harmful gas to prevent fire, ponding and battery leakage risks.
- Unattended operation: Remote cloud platform monitoring + local touch screen viewing reduces manual inspection and cuts O&M costs.
- Linkage control: High-Grade version supports automatic start/stop of air conditioners and fans to adjust computer room temperature & humidity and secure optimal equipment operating environment.
10.2 Outdoor Base Station Environmental Monitoring Solution
10.2.1 Demand Pain Points
Exposed to natural environments, outdoor base stations face risks of extreme high/low temperature, sandstorms, rainwater, typhoons and illegal trespassing/theft of equipment, accompanied by harsh environments, high O&M difficulty and frequent equipment failures, requiring all-weather full-range monitoring and security early warning.
10.2.2 Solution Design
Adopt High-Grade System. Deploy high-precision temperature & humidity sensors (inside cabinets), water leakage sensors (cabinet bottom), smoke sensors (inside cabinets), dust sensors (inside cabinets), air pressure sensors (outside cabinets), wind speed & direction sensors (top of communication towers) and infrared intrusion sensors (around cabinets). Equip solar power supply system for off-grid outdoor base stations, and connect to cloud platform via enhanced 5G industrial gateway to realize real-time monitoring of environmental parameters, meteorological data, security status and equipment status, early warning of extreme weather, illegal trespassing alarms and remote O&M management.
10.2.3 Solution Advantages
- Extreme environment adaptability: Industrial-grade IP65~IP68 protection and wide-temperature design, resistant to high/low temperature, water, dust and sandstorms for complex outdoor environments.
- Meteorological early warning: Wind speed, wind direction and air pressure monitoring provides advance warning of typhoons and strong winds to avoid tower tilt and equipment damage.
- Intelligent security: Linkage of infrared intrusion and access control to real-time monitor unauthorized trespassing and cabinet door opening, guarding against equipment theft and sabotage.
- Long endurance & maintenance-free: Solar power supply system applicable to off-grid outdoor base stations to reduce O&M costs.
10.3 Mountain / Remote Base Station Environmental Monitoring Solution
10.3.1 Demand Pain Points
Mountain/remote base stations lack mains power, suffer inconvenient transportation and weak signals, and are difficult for O&M staff to access. Equipment is prone to damage caused by abnormal temperature & humidity, water leakage and battery faults, with extremely high manual inspection costs and slow emergency response.
10.3.2 Solution Design
Adopt High-Grade System equipped with solar power supply and low-power equipment. Deploy temperature & humidity sensors, water leakage sensors, smoke sensors, access control sensors and battery monitoring modules, select low-power NB-IoT/LoRa wireless DTU for data transmission, and configure large-capacity solar power supply system. Realize low-power, long-endurance, maintenance-free operation and remote early warning via cloud platform without on-site manual inspection.
10.3.3 Solution Advantages
- Low power consumption & long endurance: Low-power sensors + solar power supply with over 7-day rainy-day endurance for off-grid remote base stations.
- Long-distance transmission: NB-IoT/LoRa wireless transmission with strong penetration and wide coverage to resolve weak signal issues in mountainous areas.
- Maintenance-free design: Industrial-grade quality and high stability reduce on-site maintenance and cut O&M costs.
- Remote early warning: Real-time push of alarms for faults and abnormal status to enable remote handling by O&M staff and accelerate emergency response.
10.4 Special Battery Monitoring Solution for Base Stations
10.4.1 Demand Pain Points
Storage batteries serve as core backup power supply for base stations. Traditional manual monitoring only measures voltage and current without tracking key parameters such as internal resistance and SOC, easily leading to battery aging, insufficient capacity, liquid leakage and overheating, which may result in failure to supply power during mains outages and disrupt base station signal coverage.
10.4.2 Solution Design
Adopt High-Grade battery monitoring module, with one set deployed per battery group to collect real-time voltage, current, temperature, internal resistance and SOC data. Upload data to cloud platform via RS485 and industrial gateway to realize real-time battery status monitoring, fault early warning, service life evaluation and data statistical analysis, with timely alarm push for abnormal status (overvoltage, undervoltage, overcurrent, high temperature, abnormal internal resistance).
10.4.3 Solution Advantages
- In-depth monitoring: Covers key operating parameters of batteries to accurately evaluate battery health status.
- Advance fault warning: Real-time monitoring of abnormal conditions to warn of faults in advance and avoid base station power outages caused by battery failure.
- Service life evaluation: Intelligent assessment of residual battery service life based on internal resistance and SOC data to formulate reasonable replacement plans and cut costs.
- Traceable historical data: Stored historical data supports query and analysis to optimize battery maintenance strategies.
11. Full Product Application Cases
11.1 Urban Core 4G/5G Base Station Monitoring Project of a Major Operator
11.1.1 Project Overview
The project covers 50 medium-sized indoor base stations in the core area of a first-tier city, featuring dense equipment, heavy foot traffic and high O&M requirements. It demands real-time environmental parameter monitoring, remote O&M and unattended operation to lower O&M costs.
11.1.2 Project Configuration
Adopt KITOZER Medium-Grade System for each base station: 2×Temperature & Humidity Sensor, 1×Water Leakage Sensor Set, 1×Smoke Sensor, 1×CO Harmful Gas Sensor, 1×Dust Sensor, 1×Access Control Sensor, 1×Battery Monitoring Module Set, 1×5G Industrial Gateway, 1×7-inch Industrial Touch Screen, 1×Power Adapter, 1×Batch Installation Auxiliary Materials.
11.1.3 Project Outcomes
- Realizes full-parameter real-time monitoring of temperature & humidity, water leakage, smoke, harmful gas, dust, access control and battery status for all 50 base stations, with data uploaded to cloud platform for remote real-time viewing.
- Timely push of abnormal alarms (SMS + APP) shortens fault response time from 24 hours to within 1 hour and reduces fault rate by 60%.
- Unattended O&M cuts manual inspection frequency by 80% and O&M costs by 50%, lifting stable operation rate of base stations to 99.9%.
11.2 Mountain 5G Base Station Monitoring Project of a Major Operator
11.2.1 Project Overview
The project covers 30 outdoor base stations in mountainous areas without mains power, featuring inconvenient transportation, heavy sandstorms and low winter temperature (-20℃). It demands environmental monitoring, meteorological early warning, security monitoring and maintenance-free operation.
11.2.2 Project Configuration
Adopt KITOZER High-Grade System for each base station: 1×High-precision Temp & Humidity Sensor, 1×Water Leakage Sensor Set, 1×Smoke Sensor, 1×Dust Sensor, 1×Air Pressure Sensor, 1×Wind Speed & Direction Sensor, 4×Infrared Intrusion Sensor, 1×Access Control Sensor, 1×Battery Monitoring Module Set, 1×Enhanced 5G Industrial Gateway, 1×10.1-inch Industrial Touch Screen, 1×Solar Power Supply System, 1×Power Adapter, 1×Batch Installation Auxiliary Materials.
11.2.3 Project Outcomes
- Adapts to extreme mountain environments with stable equipment operation within -30℃~80℃ wide temperature range and IP65~IP68 waterproof & dustproof sandstorm resistance.
- Solar power supply + low-power design delivers over 7-day rainy-day endurance without mains power and maintenance-free operation.
- Wind speed, wind direction and air pressure monitoring successfully issued early warnings for 3 typhoons and 5 strong wind events, avoiding tower tilt and equipment damage; 10 illegal intrusion alarms prevented equipment theft.
- Remote cloud platform monitoring eliminates on-site manual inspection, cutting O&M costs by 90% and lifting base station stable operation rate to 99.8%.
11.3 Outdoor Integrated Cabinet Base Station Reconstruction Project of a Communications Company
11.3.1 Project Overview
This reconstruction project covers 200 integrated outdoor cabinets distributed in suburban areas and roadside locations, demanding cabinet internal environmental monitoring, unauthorized door opening alarms and battery status monitoring to secure stable operation of internal equipment.
11.3.2 Project Configuration
Adopt KITOZER Low-Grade System + High-Grade Battery Monitoring Module for each cabinet: 1×Temp & Humidity Sensor, 1×Water Leakage Sensor, 1×Smoke Sensor, 1×Access Control Sensor, 1×Battery Monitoring Module Set, 1×4G Industrial Gateway, 1×4.3-inch Industrial Touch Screen, 1×Power Adapter, 1×Batch Installation Auxiliary Materials.
11.3.3 Project Outcomes
- Low-cost reconstruction fits narrow space of integrated cabinets with simple installation and short deployment cycle.
- Real-time monitoring of cabinet internal temperature & humidity, water leakage, smoke and access control status, with timely alarms for unauthorized door opening and abnormal temperature/humidity/water leakage.
- Real-time battery status monitoring provides advance aging & fault warnings, cutting battery replacement costs by 30%.
- Post-reconstruction equipment failure rate of cabinets reduced by 70% and O&M efficiency lifted by 60%, winning high customer recognition.
12. Full Product Faults & Maintenance
12.1 Temperature & Humidity Sensor
12.1.1 Common Faults
- No data display: Abnormal power supply, disconnected communication cable or damaged sensor.
- Severe data deviation: Sensor aging, improper installation position, environmental interference or lack of calibration.
- Data fluctuation: Electromagnetic interference, unstable communication or faulty sensor.
12.1.2 Maintenance & Care
- Monthly inspection: Check tightness of power and communication cables for looseness or damage.
- Calibration: Conduct calibration every 6 months by comparing with standard thermo-hygrometers; high-grade models may be calibrated annually.
- Cleaning: Wipe sensor probe every 3 months to remove dust and oil stains that impair sensing precision.
- Replacement: Service life of sensors is 3~5 years; replace expired units promptly to avoid abnormal data caused by aging.
12.2 Water Leakage Sensor
12.2.1 Common Faults
- No alarm for water leakage: Excessively high probe installation position, contaminated probe, abnormal power supply or disconnected cable.
- False alarms: High ambient humidity, water stains on probe or short-circuited cable, damaged sensor.
12.2.2 Maintenance & Care
- Monthly inspection: Check probe installation position and cable connection to ensure probes fit closely to ground without damaged cables.
- Cleaning: Wipe probe monthly to remove dust, oil and water stains preventing false/missed alarms.
- Testing: Conduct water leakage test every 3 months by touching probe with small volume of water to verify normal alarm function.
- Replacement: Service life of sensors is 2~3 years; replace aging waterproof cables and expired sensors in advance.
12.3 Smoke Sensor
12.3.1 Common Faults
- No alarm: Contaminated and blocked probe, abnormal power supply, disconnected cable or reduced sensitivity.
- False alarms: Dust, water vapor and lampblack entering sensor or environmental interference.
12.3.2 Maintenance & Care
- Quarterly cleaning: Wipe sensor housing and probe to remove dust and oil stains avoiding blockage.
- Testing: Conduct smoke test every 6 months with smoke generator to verify normal alarm function.
- Monthly inspection: Check power supply and cable connections; avoid installation in locations with heavy lampblack and water vapor.
- Replacement: Service life of sensors is 3~5 years; replace units with degraded sensitivity in advance.
12.4 Industrial Gateway
12.4.1 Common Faults
- Failed data upload: Network abnormality, overdue SIM card, loose antenna, gateway crash or incorrect parameter configuration.
- Unstable data transmission: Weak signal, electromagnetic interference, insufficient bandwidth or faulty gateway.
- Login failure: Changed IP address, incorrect account/password or damaged gateway.
12.4.2 Maintenance & Care
- Monthly inspection: Check antenna connection, SIM card status and power supply, verify signal strength meets standard.
- Regular restart: Reboot gateway every 3 months to clear cache and avoid crash; restart first for troubleshooting.
- Parameter backup: Back up gateway configuration parameters every 6 months to avoid full reconfiguration after parameter loss.
- Firmware upgrade: Upgrade firmware annually per manufacturer releases to repair vulnerabilities and optimize performance.
- Dustproof & heat dissipation: Maintain well-ventilated and dry installation environment to prevent dust accumulation and high temperature affecting operation.
12.5 Industrial Touch Screen
12.5.1 Common Faults
- Blank screen: Abnormal power supply, damaged screen or disconnected cable.
- Touch failure: Contaminated screen, damaged touch panel or system lag.
- Static data: Communication abnormality, faulty gateway or crashed touch screen.
12.5.2 Maintenance & Care
- Monthly cleaning: Wipe screen surface with soft dry cloth; avoid corrosive detergents.
- Monthly inspection: Check tightness of power and communication cables for looseness or damage.
- Regular restart: Reboot touch screen every 3 months to clear cache and avoid crash.
- Protection: Avoid direct sunlight, high temperature and humid environments to