4G/5G Base Station Heat Dissipation Equipment Solution

Table of Contents

1. System Overview

4G/5G base station heat dissipation equipment is a critical supporting system that guarantees stable operation of core devices including Remote Radio Units (RRU), Base Band Units (BBU), and power modules. The power consumption of a single 5G base station is 2–3 times that of a 4G station, and ultra-high heat flux density (up to 300W/cm²) easily causes equipment frequency reduction, downtime, or even burnout.

Integrating four core technologies—air cooling, heat pipe, liquid cooling, and intelligent control—the KITOZER base station heat dissipation system is designed under the philosophy of “graded heat dissipation, priority of natural cold sources, and intelligent linkage”. It provides three standardized solution tiers (low, medium, high) for different power levels (1–20kW) and scenarios (outdoor macro base stations, indoor micro base stations, machine rooms). The system achieves heat dissipation efficiency ≥95%, energy saving rate ≥40%, Mean Time Between Failures (MTBF) ≥80,000 hours, and stable operation under a wide temperature range of -40℃ to +85℃, adapting to global 4G/5G base station construction and energy-saving renovation projects.

2. System Composition

The KITOZER heat dissipation system consists of five modular units that coordinate to form a closed-loop heat dissipation circuit: core heat dissipation unit, intelligent control unit, thermal interface unit, structural protection unit, and auxiliary unit.

  • Core Heat Dissipation Unit: Axial cooling fans, heat pipe radiators, vapor chambers, cold plate liquid cooling assemblies, spray liquid cooling modules, air-to-air/water-to-water heat exchangers.
  • Intelligent Control Unit: PLC temperature controllers, temperature sensors (NTC/PT100), wind speed/liquid level sensors, linkage controllers, remote monitoring modules (supporting SNMP/Modbus protocols).
  • Thermal Interface Unit: High thermal conductivity gel (8–15W/m·K), thermal grease (6–12W/m·K), graphene thermal pads, liquid metal interface materials.
  • Structural Protection Unit: IP55/IP65 protective enclosures, anti-corrosion aluminum alloy frames, dust filter screens (aperture ≤0.8mm), weather-resistant silicone rubber waterproof seals, seismic fixing brackets.
  • Auxiliary Unit: Cooling fans, circulating water pumps, expansion water tanks, cooling fluids (deionized water/ethylene glycol mixture/fluorinated liquid), connecting pipelines, quick connectors, lightning protection and grounding assemblies.

3. System Classification

Classified by four dimensions: heat dissipation principle, power adaptation, installation scenario, and cooling medium, covering full-scenario application demands.

3.1 Classification by Heat Dissipation Principle

  1. Natural Convection Heat Dissipation System (Low Power ≤3kW) Equipped with heat sinks, heat pipes, and radiation coatings; zero energy consumption, ultra-quiet (≤25dB). Applicable to outdoor micro base stations and remote base stations.
  2. Forced Air Cooling System (Medium Power 3–8kW) Combines axial fans, heat dissipation fins, and intelligent speed regulation. Its heat exchange efficiency is 3–5 times higher than natural convection, with heat flux density up to 0.3W/cm². Suitable for outdoor macro base stations and indoor cabinets.
  3. Heat Pipe / Vapor Chamber Heat Dissipation System (Medium-High Power 5–12kW) Adopts copper vacuum heat pipes (thermal conductivity ≥500W/m·K) and vapor chambers to rapidly equalize temperature via phase-change heat transfer, with thermal resistance ≤0.005K·m²/W. Ideal for high-density RRU/BBU clusters.
  4. Liquid Cooling System (High Power ≥10kW)
    • Cold Plate Liquid Cooling: Indirect contact heat dissipation, matching BBU pools and cabinet clusters, energy saving rate ≥40%.
    • Immersion Liquid Cooling: Full immersion in fluorinated liquid, heat dissipation efficiency ≥98%, for ultra-high-density computing base stations.
    • Spray Liquid Cooling: Direct spraying on heating components, capable of dissipating heat flux density up to 300W/cm², for high-power RRUs of 5G macro base stations.
  5. Hybrid Heat Dissipation System (Full Power 1–20kW) Combines air cooling with heat pipes/liquid cooling; intelligently switches between natural cold sources and mechanical refrigeration, with Coefficient of Performance (COP) ≥16.15.

3.2 Classification by Installation Scenario

  1. Outdoor Macro Base Station Heat Dissipation System IP65 protection, weather resistance from -40℃ to +85℃, 12-level wind resistance, lightning protection; compatible with tower and pole mounting.
  2. Indoor Micro Base Station / Machine Room Heat Dissipation System IP55 protection, low noise ≤45dB, modular rack-mounted installation; fits indoor cabinets and indoor BBU clusters.
  3. Integrated Cabinet Heat Dissipation System Integrates heat dissipation, monitoring, and power distribution; matches outdoor all-in-one base station cabinets for rapid deployment.

4. System Schematic Diagrams

4.1 Forced Air Cooling System Working Principle

Base station heating equipment (RRU/BBU) → high thermal conductivity interface materials → fin assembly → intelligently variable-speed axial fans → hot air exhaust → natural air cooling → cold air recirculation → cyclic heat dissipation

↑

Temperature sensors → PLC temperature controller (linking fan speed regulation & fault alarms)

4.2 Cold Plate Liquid Cooling System Working Principle

Heating chips of BBU/RRU → thermal interface materials → micro-channel cold plates (absorb heat via secondary cooling fluid) → Cooling Distribution Unit (CDU, integrated circulation pump & heat exchanger) → primary cooling fluid (heat dissipation) → outdoor cooling tower/heat exchanger (HEX) → heat discharged into atmosphere → cooled fluid recirculation → cyclic heat dissipation

↑

Temperature/liquid level sensors → intelligent controller (linking pump speed, alarms & air conditioning)

4.3 Hybrid Heat Pipe Cooling System Working Principle

Heating equipment → 6063 high thermal conductivity aluminum carrier → embedded heat pipes (heat absorption at evaporation section) → heat pipe condensation section → T-type radiator (fins + fans) → heat exhaust → natural cooling → circulation

↑

Temperature control module (intelligent fan start-stop)

5. Three-Tier System Configuration List

5.1 Low-Tier Configuration (For ≤3kW Low-Power Base Stations, Natural Convection + Auxiliary Air Cooling)

表格

No.Product NameModelTechnical ParametersQtyUnitBrandRemarks
1High Thermal Conductivity Heat SinkKTZ-SINK-L16063 aluminum alloy, thermal conductivity ≥201W/m·K, size 200×150×50mm, anodized surface, thermal resistance ≤8℃/W1SetKITOZERFor single RRU heat dissipation
2Copper Heat PipeKTZ-HT-L2OD 8mm, length 200mm, vacuum copper pipe, pure water working fluid, thermal conductivity ≥500W/m·K, operating temp -40℃~+120℃4PcsKITOZEREmbedded in heat sink to boost heat transfer
3Mini Axial FanKTZ-FAN-L380×80×25mm, DC12V, 5W power, airflow 15CFM, 3000RPM, noise ≤35dB, IP541UnitKITOZERIntelligent start-stop, auxiliary cooling
4NTC Temperature SensorKTZ-SEN-L4Measuring range -40℃~+85℃, accuracy ±0.5℃, 10kΩ resistance, B-value 3950, 1m cable1PcKITOZERCollect surface temperature of equipment
5Basic Temperature ControllerKTZ-CTRL-L5DC12V input, measuring range -40℃~+85℃, switch output, control accuracy ±1℃, fan linkage support1UnitKITOZERFan linkage control
6Thermal GreaseKTZ-TIM-L6Thermal conductivity 6W/m·K, white, working temp -50℃~+180℃, 10g/tube, thermal resistance ≤0.8℃·cm²/W1TubeKITOZERFill gaps between heating surface & heat sink
7Protective EnclosureKTZ-HSG-L7Cold-rolled steel, IP54 protection, size 250×200×80mm, anti-corrosion coating, dustproof & waterproof1PcKITOZERProtect heat dissipation components
8Mounting BracketKITOZER-BRACKET-L8Galvanized steel, load ≥10kg, adjustable angle, pole/wall mounting compatible1SetKITOZERFix heat dissipation system

5.2 Medium-Tier Configuration (For 3–8kW Medium-Power Base Stations, Forced Air Cooling + Heat Pipe + Intelligent Control)

表格

No.Product NameModelTechnical ParametersQtyUnitBrandRemarks
1T-Type Heat Pipe RadiatorKTZ-HTS-M16063 aluminum alloy + copper heat pipes, size 300×200×80mm, thermal conductivity ≥220W/m·K, thermal resistance ≤3℃/W, 8 embedded heat pipes, anti-corrosion anodization1SetKITOZERCombined heat dissipation for RRU/BBU
2High-Efficiency Axial FanKTZ-FAN-M2120×120×38mm, AC220V, 15W, airflow 45CFM, 2800RPM, noise ≤42dB, IP55, ±10% wide voltage2UnitsKITOZERRedundant design, intelligent speed regulation
3Vapor ChamberKTZ-VC-M3250×180×5mm, copper vacuum chamber, ethanol working fluid, thermal conductivity ≥800W/m·K, temperature uniformity ≤2℃, working temp -40℃~+150℃1PcKITOZEREvenly distribute hot spot heat
4PT100 Temperature SensorKTZ-SEN-M4Measuring range -50℃~+100℃, accuracy ±0.2℃, 3-wire, 2m waterproof probe, IP652PcsKITOZERCollect equipment & ambient temperature
5Intelligent PLC Temperature ControllerKTZ-CTRL-M5AC220V input, measuring range -50℃~+100℃, accuracy ±0.5℃, 4 relay outputs, fan speed regulation/alarm/AC linkage, LCD display1UnitKITOZERCore system controller
6High Thermal Conductivity GelKTZ-TIM-M6Thermal conductivity 10W/m·K, gray, working temp -55℃~+200℃, 50g/tube, thermal resistance ≤0.3℃·cm²/W, anti-aging1TubeKITOZERFill gaps for high heat flux density
7Dust Filter ScreenKTZ-FILTER-M70.6mm aperture, polyester fiber, size 150×150mm, washable, dust removal efficiency ≥95%2PcsKITOZERFilter intake dust
8IP55 Protective CabinetKTZ-CAB-M8Galvanized steel, IP55, size 350×250×120mm, anti-corrosion coating, louver vents1PcKITOZERIntegrate and protect all components
9Seismic Mount AssemblyKTZ-ANTI-M9Stainless steel, load ≥20kg, Grade 8 seismic resistance, tower/pole mounting compatible1SetKITOZERStable installation, anti-vibration

5.3 High-Tier Configuration (For ≥10kW High-Power Base Stations, Cold Plate Liquid Cooling + Hybrid Heat Pipe + Remote Monitoring)

表格

No.Product NameModelTechnical ParametersQtyUnitBrandRemarks
1Cold Plate Liquid Cooling AssemblyKTZ-LC-H1Aluminum substrate + copper microchannels, size 400×300×15mm, working pressure ≤1.6MPa, thermal conductivity ≥300W/m·K, fits high-power chips of BBU/RRU1SetKITOZERCore liquid cooling component
2Cooling Distribution Unit (CDU)KTZ-CDU-H2AC220V, 500W power, adjustable flow 5–10L/min, working pressure 0.4–0.8MPa, integrated liquid level/pressure/temp monitoring, secondary fluid distribution1UnitKITOZERCoolant circulation & distribution
3Liquid-Air Heat Exchanger (HEX)KTZ-HEX-H3Heat transfer coefficient ≥530W/K, finned aluminum, size 500×400×200mm, working temp -40℃~+80℃, heat dissipation power ≥12kW1UnitKITOZERDischarge heat outdoors
4Vacuum Heat Pipe ArrayKTZ-HTA-H4OD10mm, length 300mm, copper vacuum pipe, fluorinated liquid working fluid, thermal conductivity ≥600W/m·K, working temp -50℃~+180℃, 12 pipes per set1SetKITOZERAuxiliary phase-change heat transfer
5Intelligent Circulation PumpKTZ-PUMP-H5DC48V, 80W power, 8L/min flow, 15m head, noise ≤38dB, IP65, brushless long-life motor1UnitKITOZERDrive coolant circulation
6Remote Monitoring TerminalKTZ-MON-H6Support SNMP v3/Modbus TCP, RJ45 Ethernet, measuring range -50℃~+120℃, accuracy ±0.3℃, real-time temp/pressure/flow monitoring, remote alarm & control1UnitKITOZERRemote operation & maintenance management
7High-Conductivity Graphene PadKTZ-TIM-H7Thermal conductivity 15W/m·K, 1mm thickness, size 300×200mm, flexible, working temp -60℃~+250℃, thermal resistance ≤0.1℃·cm²/W1PcKITOZERUltra-high heat flux interface cooling
8Mixed CoolantKTZ-LIQUID-H850:50 deionized water & ethylene glycol, freezing point -35℃, boiling point 108℃, insulation resistance ≥1MΩ, non-corrosive, 5L/barrel1BarrelKITOZERSecondary cooling medium
9IP65 Outdoor CabinetKTZ-CAB-H9304 stainless steel, IP65, size 600×500×250mm, rust-proof, weather-resistant -40℃~+85℃, integrated lightning protection grounding1PcKITOZEROutdoor integrated protection
10Quick Connectors & PipelinesKTZ-PIPE-H10DN15 stainless steel quick connectors, 2MPa pressure-resistant PU pipelines, 5m length, temp resistance -40℃~+120℃, leak-proof1SetKITOZERLiquid cooling system connection

6. Full Product Technical Specifications

6.1 Heat Sink (KTZ-SINK-L1)

  • Material: 6063 aluminum alloy, thermal conductivity ≥201W/m·K
  • Dimension: 200×150×50mm (L×W×H)
  • Surface Treatment: Black anodization, corrosion resistance
  • Thermal Resistance: ≤8℃/W (natural convection)
  • Operating Temperature: -40℃~+120℃
  • Weight: ≤2.5kg

6.2 Copper Heat Pipe (KTZ-HT-L2)

  • Material: Copper shell, pure water working fluid, copper powder sintered wick
  • Spec: OD8mm, length 200mm
  • Thermal conductivity ≥500W/m·K, thermal response time ≤2s
  • Operating Temperature: -40℃~+120℃, limit temp 150℃
  • Vacuum Degree: ≤1×10⁻³Pa
  • Minimum Bending Radius: ≥20mm (customizable)

6.3 Mini Axial Fan (KTZ-FAN-L3)

  • Size: 80×80×25mm
  • Power Supply: DC12V±10%, 5W
  • Performance: Airflow 15CFM, 3000RPM, static pressure 1.2mmH₂O
  • Noise: ≤35dB(A)
  • Protection Grade: IP54, dust & splash proof
  • Service Life: ≥50,000 hours @ 25℃ ambient temp

6.4 T-Type Heat Pipe Radiator (KTZ-HTS-M1)

  • Material: 6063 aluminum carrier & fins + 8 copper heat pipes
  • Dimension: 300×200×80mm
  • Thermal conductivity ≥220W/m·K, thermal resistance ≤3℃/W
  • Fin Density: 12 fins per inch, total heat dissipation area ≥0.8m²
  • Operating Temperature: -40℃~+150℃
  • Protection Grade: IP55, anti-corrosion anodization

6.5 Vapor Chamber (KTZ-VC-M3)

  • Material: Copper shell, ethanol working fluid, multi-layer copper mesh wick
  • Dimension: 250×180×5mm
  • Thermal conductivity ≥800W/m·K, full-load temperature uniformity ≤2℃
  • Operating Temperature: -40℃~+150℃, limit temp 180℃
  • Pressure Resistance: ≤1.2MPa
  • Weight: ≤1.2kg

6.6 High-Efficiency Axial Fan (KTZ-FAN-M2)

  • Size: 120×120×38mm
  • Power Supply: AC220V±10%, 50Hz, 15W
  • Performance: Airflow 45CFM, 2800RPM, static pressure 2.5mmH₂O
  • Noise: ≤42dB(A)
  • Protection Grade: IP55, waterproof & dustproof
  • Service Life: ≥60,000 hours @ 25℃ ambient temp

6.7 Cold Plate Liquid Cooling Assembly (KTZ-LC-H1)

  • Material: Aluminum substrate + 2mm-diameter copper microchannels
  • Dimension: 400×300×15mm
  • Thermal conductivity ≥300W/m·K, thermal resistance ≤0.8℃/W
  • Working Pressure: ≤1.6MPa, test pressure 2.4MPa
  • Operating Temperature: -50℃~+180℃
  • Interface: DN15 stainless steel quick connectors
  • Weight: ≤3.5kg

6.8 Cooling Distribution Unit (CDU, KTZ-CDU-H2)

  • Power Supply: AC220V±10%, 50Hz, 500W max power
  • Flow Rate: 5–10L/min (adjustable)
  • Pressure Range: 0.4–0.8MPa operating pressure, 1.2MPa protection pressure
  • Monitoring Functions: Liquid level, pressure, PT100 temperature, flow rate
  • Control: PLC intelligent control, speed regulation & fault alarm linkage
  • Protection Grade: IP55, dimension 400×300×200mm
  • Operating Temperature: -40℃~+85℃

6.9 Liquid-Air Heat Exchanger (HEX, KTZ-HEX-H3)

  • Material: Aluminum fins & shell, copper pipelines
  • Heat Transfer Coefficient ≥530W/K, heat dissipation power ≥12kW
  • Dimension: 500×400×200mm
  • Operating Temperature: -40℃~+80℃
  • Working Pressure: ≤1.2MPa
  • Protection Grade: IP55, anti-corrosion coating
  • Weight: ≤8kg

6.10 Intelligent PLC Temperature Controller (KTZ-CTRL-M5)

  • Power Supply: AC220V±10%, 50Hz
  • Measuring Range: -50℃~+100℃, accuracy ±0.5℃
  • Input Ports: 2×PT100/NTC, 1×ambient temperature sensor
  • Output Ports: 4 relay outputs (250VAC/5A), 0–10V fan speed regulation
  • Display: LCD screen, real-time temperature, rotation speed & fault alarm
  • Functions: Intelligent start-stop, linkage control, high-temp alarm (≥55℃), low-temp protection (≤-10℃)
  • Protection Grade: IP54, dimension 150×100×50mm

6.11 Remote Monitoring Terminal (KTZ-MON-H6)

  • Communication: RJ45 Ethernet, support SNMP v3 / Modbus TCP
  • Measuring Range: -50℃~+120℃, accuracy ±0.3℃
  • Monitored Parameters: Temperature, pressure, flow rate, liquid level, fan speed, equipment voltage
  • Functions: Real-time data upload, remote control (fans/pumps/air conditioners), abnormal alarms (SMS/APP), historical data storage (≥1 year)
  • Power Supply: DC24V, 10W power consumption
  • Protection Grade: IP55, dimension 200×150×80mm

6.12 Thermal Interface Materials

  1. Thermal Grease (KTZ-TIM-L6): Thermal conductivity 6W/m·K, working temp -50℃~+180℃, thermal resistance ≤0.8℃·cm²/W
  2. Thermal Gel (KTZ-TIM-M6): Thermal conductivity 10W/m·K, working temp -55℃~+200℃, thermal resistance ≤0.3℃·cm²/W
  3. Graphene Pad (KTZ-TIM-H7): Thermal conductivity 15W/m·K, 1mm thickness, working temp -60℃~+250℃, thermal resistance ≤0.1℃·cm²/W

7. Full Product Application Scope

7.1 Heat Sink / Heat Pipe Series

  • 4G/5G outdoor micro base stations (power ≤3kW)
  • Off-grid remote base stations powered by solar energy
  • Small RRU equipment, microwave communication devices
  • Industrial control equipment, small outdoor cabinets

7.2 Heat Pipe Radiator / Vapor Chamber Series

  • 4G/5G outdoor macro base stations (RRU power 3–8kW)
  • Indoor micro base stations, single BBU cabinets in machine rooms
  • High-density RF modules, high-power power supplies
  • Edge computing base stations, small data cabinets

7.3 Liquid Cooling Series (Cold Plate / CDU / HEX)

  • High-power 5G macro base stations (RRU ≥10kW)
  • Pooled BBU machine rooms, centralized baseband machine rooms
  • Ultra-high-density computing base stations, AI edge computing nodes
  • Large data center cabinets, telecom core machine rooms

7.4 Intelligent Control / Monitoring Series

  • Full-scenario supporting for all 4G/5G base station heat dissipation systems
  • Energy-saving renovation projects for base stations (air cooling to hybrid cooling upgrade)
  • Unattended base stations requiring remote operation & maintenance
  • Multi-base station cluster management, provincial/municipal operation & maintenance platforms

7.5 Protection / Mounting Series

  • Outdoor base stations (tower, pole, wall mounting)
  • Outdoor all-in-one cabinets, rainproof & dustproof environments
  • Seismic base stations (earthquake-prone zones), coastal salt-fog environments
  • Extreme temperature base stations (desert high temperature, frigid low temperature)

8. Core Advantages of All Products

8.1 Core Functional Features

  1. High-Efficiency Heat Dissipation Adopt high thermal conductivity materials (aluminum, copper, graphene). Heat pipe thermal conductivity ≥500W/m·K, liquid cooling heat exchange efficiency ≥98%, energy saving rate ≥40% vs traditional air cooling, solving high heat pain points of 5G equipment.
  2. Wide Temperature Adaptability Operating range -40℃~+85℃, adaptable to global extreme environments including high-temperature deserts, frigid zones, and coastal salt fog, with outstanding weather resistance.
  3. Intelligent Control Dual control via PLC + remote monitoring; intelligently adjust temperature, fan speed, and fluid flow with priority given to natural cold sources, COP ≥16.15, cutting energy consumption and operation costs.
  4. High Reliability Core components (fans, pumps, heat pipes) MTBF ≥80,000 hours; IP54–IP65 protection grades, dustproof, waterproof and seismic, perfectly matching unattended base station operation.
  5. Modular Design Standardized low/medium/high tier modules, plug-and-play, compatible with all power-level base stations for fast deployment and easy maintenance.

8.2 Customization Services

  • Size Customization: Custom dimensions for heat sinks, heat pipes and cold plates to fit non-standard cabinets and equipment space.
  • Power Customization: Adjustable heat dissipation power 1–20kW, matching optimal solutions for different RRU/BBU power ratings.
  • Interface Customization: Custom liquid cooling connectors (DN10/DN15/DN20) and communication ports (RS485/Ethernet) to integrate with existing systems.
  • Material Customization: Aluminum alloy for regular environments, 304 stainless steel for salt-fog areas, titanium alloy for high-temperature scenarios as required.

8.3 Production & Supply Chain Advantages

  • OEM/ODM Processing Support: One-stop service including drawing design, mold opening, production and testing; confidential manufacturing to protect client intellectual property.
  • Non-Disclosure Agreements: Strictly sign NDAs to safeguard client technical plans, drawings and parameters against leakage.
  • Spot Inventory: Core components (fans, heat pipes, temperature controllers) stocked in bulk, delivery within 72 hours for urgent projects.
  • Fully Self-Developed Product Line: Independent R&D and production covering thermal materials, core parts and control systems, stable quality and prominent cost advantages.

8.4 Technical Parameter Superiority

  • Ultra-High Thermal Conductivity: Heat pipe ≥500W/m·K, vapor chamber ≥800W/m·K, liquid cooling heat exchanger ≥530W/K, leading industry indicators.
  • Ultra-Low Thermal Resistance: Heat sink ≤8℃/W, heat pipe radiator ≤3℃/W, cold plate ≤0.8℃/W, maximizing heat transfer efficiency.
  • Wide Voltage Compatibility: Fans and temperature controllers support AC220V±10% / DC12V / DC48V, matching multiple base station power supply modes.
  • Long Service Life Design: Fans & pumps service life 50,000–60,000 hours; heat pipes and vapor chambers require zero maintenance throughout lifespan, reducing operation costs.

9. Bid-Winning Core Parameters (Marked with ★)

9.1 Heat Sink (KTZ-SINK-L1)

  • ★Material: 6063 aluminum alloy, thermal conductivity ≥201W/m·K
  • ★Thermal Resistance: ≤8℃/W (natural convection)
  • ★Operating Temperature: -40℃~+120℃

9.2 Copper Heat Pipe (KTZ-HT-L2)

  • ★Material: Copper shell + pure water working fluid, thermal conductivity ≥500W/m·K
  • ★Operating Temperature: -40℃~+120℃
  • ★Vacuum Degree: ≤1×10⁻³Pa

9.3 T-Type Heat Pipe Radiator (KTZ-HTS-M1)

  • ★Material: 6063 aluminum alloy + copper heat pipes, thermal conductivity ≥220W/m·K
  • ★Thermal Resistance: ≤3℃/W
  • ★Protection Grade: IP55

9.4 Vapor Chamber (KTZ-VC-M3)

  • ★Material: Copper shell + ethanol working fluid, thermal conductivity ≥800W/m·K
  • ★Temperature Uniformity: ≤2℃ under full load
  • ★Operating Temperature: -40℃~+150℃

9.5 Cold Plate Liquid Cooling Assembly (KTZ-LC-H1)

  • ★Material: Aluminum alloy + copper microchannels, thermal conductivity ≥300W/m·K
  • ★Working Pressure: ≤1.6MPa
  • ★Thermal Resistance: ≤0.8℃/W

9.6 Cooling Distribution Unit (CDU, KTZ-CDU-H2)

  • ★Power Supply: AC220V±10%, power ≤500W
  • ★Flow Rate: 5–10L/min (adjustable)
  • ★Monitoring: Full-parameter monitoring for liquid level, pressure, temperature and flow rate
  • ★Protection Grade: IP55

9.7 Liquid-Air Heat Exchanger (HEX, KTZ-HEX-H3)

  • ★Heat Transfer Coefficient: ≥530W/K
  • ★Heat Dissipation Power: ≥12kW
  • ★Operating Temperature: -40℃~+80℃

9.8 Intelligent PLC Temperature Controller (KTZ-CTRL-M5)

  • ★Measuring Range: -50℃~+100℃, accuracy ±0.5℃
  • ★Output Ports: ≥4 relay outputs, support 0–10V fan speed regulation
  • ★Functions: Intelligent start-stop, linkage control, high-temperature alarm (≥55℃)

9.9 Remote Monitoring Terminal (KTZ-MON-H6)

  • ★Communication: Support SNMP v3 / Modbus TCP protocols
  • ★Temperature Measurement Accuracy: ±0.3℃
  • ★Functions: Remote control, abnormal alarms, historical data storage (≥1 year)

9.10 Thermal Interface Materials

  • ★Thermal Grease: Thermal conductivity ≥6W/m·K, thermal resistance ≤0.8℃·cm²/W
  • ★Thermal Gel: Thermal conductivity ≥10W/m·K, thermal resistance ≤0.3℃·cm²/W
  • ★Graphene Pad: Thermal conductivity ≥15W/m·K, thermal resistance ≤0.1℃·cm²/W

10. Complete Product Solution Packages

10.1 Natural Convection Solution for Low-Power Base Stations (≤3kW)

Pain Points: Remote base stations without mains power, high heat dissipation energy consumption, difficult maintenance.

Solution: Low-tier configuration combining heat sinks, heat pipes and mini auxiliary fans, natural convection as primary cooling, DC12V fans powered by solar energy, IP54 protection and maintenance-free design.

Effect: Equipment temperature stabilized between -10℃ and +50℃, heat dissipation efficiency ≥85%, zero extra power consumption, ideal for off-grid sites.

10.2 Hybrid Forced Air + Heat Pipe Solution for Medium-Power Base Stations (3–8kW)

Pain Points: Severe heat generation from 5G macro station RRUs, low efficiency and high power consumption of traditional air cooling, excessive noise.

Solution: Medium-tier setup including T-type heat pipe radiators, vapor chambers, high-efficiency variable-speed fans and intelligent PLC controllers. Fans activate above 45℃ and shut down below 35℃, linking with station air conditioners and prioritizing natural cold sources.

Effect: Equipment temperature maintained 0℃~+55℃, heat dissipation efficiency ≥92%, energy saving rate ≥40%, noise ≤42dB, perfectly suited for outdoor macro base stations.

10.3 Cold Plate Liquid Cooling Solution for High-Power Base Stations (≥10kW)

Pain Points: Ultra-high heat flux density of high-power 5G RRU/BBU clusters; air cooling fails to dissipate heat and causes extreme power consumption in machine rooms.

Solution: High-tier liquid cooling system with cold plates, CDU, HEX and remote monitoring terminals. Cold plates fit closely to heating chips, circulating coolant carries heat away and outdoor HEX discharges waste heat; intelligent regulation of fluid flow and temperature with air conditioner linkage.

Effect: Equipment temperature controlled 10℃~+50℃, heat dissipation efficiency ≥98%, energy saving rate ≥60%, capable of dissipating heat flux density up to 300W/cm² for high-power equipment clusters.

10.4 Base Station Energy-Saving Renovation Solution (Air Cooling Upgrade to Hybrid Cooling)

Pain Points: Old 4G base station air conditioners consume massive electricity; heat generation surges after 5G transformation leading to insufficient cooling, high operation costs.

Solution: Retain original air conditioners, add heat pipe radiators, intelligent temperature control and remote monitoring. Natural cold source priority mode: heat pipes run and air conditioners shut down when ambient temp ≤25℃; air conditioners activate for temperatures above 25℃ with intelligent linkage.

Effect: Air conditioner operating time reduced by 60%, annual energy saving rate ≥50%, carbon emission reduction of 3–6 tons per year, applicable to renovation of legacy base stations.

10.5 Heat Dissipation Solution for Extreme Environment Base Stations (High Temp / Low Temp / Salt Fog)

Pain Points: System failures caused by desert high temperature (+60℃), frigid low temperature (-40℃) and coastal salt fog corrosion.

Solutions by Scenario:

  1. High-Temperature Zones: High-tier liquid cooling configuration + high-boiling coolant (120℃ boiling point) + sun-proof cabinets.
  2. Low-Temperature Zones: Heat pipe radiators + low-freezing-point working fluid (-50℃ freezing point) + optional heating modules.
  3. Salt-Fog Coastal Zones: Full-system 304 stainless steel construction, anti-corrosion coating and IP65 protection grade. Effect: Stable operation under extreme climates, failure rate ≤0.1%, service life ≥8 years, adaptable to special global environments.

11. Application Cases

11.1 Energy-Saving Renovation Project of No.6 Base Station, Beibu Gulf University (Medium-Tier Configuration)

Project Background: Mixed 4G/5G base station; original air conditioner consumed 28,000 kWh per year, heat load increased by 30% after 5G upgrade leading to air conditioner overload.

Adopted Solution: KITOZER hybrid heat pipe cooling system (KTZ-HTS-M1 + KTZ-CTRL-M5), intelligently linked with original air conditioning equipment.

Achieved Results: Air conditioner runtime cut by 65%, annual power consumption reduced to 11,000 kWh, energy saving rate 60.7%, annual carbon emission reduction of 6.06 tons; equipment temperature stabilized 35–50℃ without overheating alarms.

11.2 5G Macro Station Cluster Liquid Cooling Project, Guangdong Telecom (High-Tier Configuration)

Project Background: Pearl River Delta 5G macro stations with single RRU power of 12kW (20 units total). Original air cooling system insufficiently dissipated heat, causing frequent summer shutdowns.

Adopted Solution: KITOZER cold plate liquid cooling system (KTZ-LC-H1 + KTZ-CDU-H2 + KTZ-HEX-H3) with cluster remote monitoring management.

Achieved Results: Equipment temperature controlled at 30–45℃, heat dissipation efficiency 98%, zero shutdown incidents, annual energy saving rate 62%, operation and maintenance costs reduced by 50%.

11.3 Natural Convection Cooling Project for Desert Base Stations in Xinjiang (Low-Tier Configuration)

Project Background: 5G micro base station on the edge of Taklamakan Desert, off-grid solar power supply, extreme ambient temperature up to +60℃ in summer where conventional cooling solutions failed.

Adopted Solution: KITOZER low-tier natural convection cooling system (KTZ-SINK-L1 + KTZ-HT-L2), IP54 protection, maintenance-free design.

Achieved Results: Equipment temperature maintained at 40–50℃, heat dissipation efficiency 88%, zero-power continuous operation, 3 years of stable operation without faults, fully adapted to desert high-temperature environments.

11.4 Salt-Fog Resistant Heat Dissipation Project for Coastal Base Stations in Zhejiang (Medium-Tier Configuration)

Project Background: 5G macro stations on Zhoushan Archipelago; severe coastal salt fog corrosion caused original cooling equipment to rust and fail within 1 year with frequent maintenance requirements.

Adopted Solution: KITOZER medium-tier heat pipe cooling system with full 304 stainless steel materials, anti-corrosion coating and IP65 protection grade.

Achieved Results: No rust or corrosion after 5 years of continuous operation, zero failure rate, equipment temperature 32–48℃, maintenance cycle extended to 2 years.

12. Common Product Faults & Maintenance Guidelines

12.1 Common Faults & Troubleshooting

表格

Fault PhenomenonRoot CausesHandling Methods
Excessively high equipment temperature (≥55℃)1. Damaged/low-speed fans; 2. Clogged heat sinks/filters; 3. Failed heat pipes; 4. Insufficient flow/leakage in liquid cooling system; 5. Malfunctioning temperature controller1. Replace fans and inspect power supply; 2. Clean heat sinks/filters with air gun; 3. Replace defective heat pipes; 4. Inspect pumps/pipelines, replenish coolant and repair leaks; 5. Calibrate or replace temperature controller
Fans fail to start1. Abnormal power supply; 2. Incorrect temperature controller setting; 3. Burned fan motor; 4. Broken wiring1. Test AC220V/DC12V power supply; 2. Reset fan startup temperature to 45℃; 3. Replace damaged fans; 4. Inspect and repair broken wiring
Low pressure in liquid cooling system1. Coolant leakage; 2. Pump malfunction; 3. Blocked pipelines; 4. Insufficient liquid level in expansion tank1. Locate leakage points, repair seals and replenish coolant; 2. Replace pumps and test power supply; 3. Clean blocked pipelines; 4. Top up coolant to standard liquid level
No data displayed on remote monitoring terminal1. Network failure; 2. Monitoring terminal power cut off; 3. Damaged sensors; 4. Mismatched communication protocols1. Inspect Ethernet cable/4G module and reboot network; 2. Check DC24V power supply; 3. Replace defective sensors; 4. Verify protocol parameters and reconfigure settings
Uneven temperature on heat pipe radiator1. Excessive installation gaps of heat pipes; 2. Coolant leakage inside heat pipes; 3. Dust accumulation on heat sinks1. Reinstall components and fill gaps with thermal gel; 2. Replace leaking heat pipes; 3. Clean dust from heat sinks

12.2 Maintenance & Service Schedules

Monthly Routine Inspection

  • Monitor equipment temperature via remote platform or on-site measurement; normal operating range: -10℃~+55℃, resolve overheating alarms immediately.
  • Inspect fan operation (rotation speed & noise); eliminate abnormal sounds and unstable rotation.
  • Check dust filter screens; clean with air gun (≤0.5MPa pressure) if dust layer exceeds 1mm thickness.
  • Examine protective cabinets for cracks and intact waterproof seals, ensure cabinet doors are fully closed.
  • Review remote monitoring historical data: confirm temperature, rotation speed, flow and pressure readings are normal with no alarm records.

Quarterly Deep Maintenance

  • Thoroughly clean heat sinks and heat pipes: blow dust with air gun and wipe with neutral detergent (avoid corrosion), fully dry before reinstallation.
  • Inspect thermal interface materials for aging and cracking; replace thermal gel/grease if thermal resistance rises abnormally.
  • Specialized liquid cooling system inspection:
    1. Coolant liquid level: maintain standard scale, replenish with identical 50:50 deionized water & ethylene glycol mixture when low.
    2. Pipelines & connectors: check for leakage and aging, fasten loose joints and replace degraded pipelines.
    3. Pumps & motors: smooth operation without abnormal noise, insulation resistance ≥1MΩ.
  • Calibrate temperature controllers and monitoring terminals: ensure ±0.5℃ measurement accuracy, functional logic and alarm triggers work properly.

Annual Full System Inspection

  • Complete disassembly inspection of all systems: no deformation or corrosion on heat sinks/heat pipes, no bearing wear on fan motors and intact motor insulation.
  • Performance testing of heat pipes & vapor chambers: thermal conductivity ≥500W/m·K and temperature uniformity ≤2℃; replace unqualified units.
  • Pressure resistance test for liquid cooling systems: hold 1.6MPa working pressure for 30 minutes with zero leakage allowed.
  • Anti-corrosion inspection of protective cabinets: touch up coating where peeling or rust occurs.
  • Grounding system test: grounding resistance ≤4Ω, reliable lightning protection grounding connection.

Critical Maintenance Precautions

  • Cut off all power (AC220V/DC48V) before maintenance, hang “No Switching On” warning signs to prevent electric shock hazards.
  • Avoid direct high-pressure airflow into internal equipment during filter/heat sink cleaning to prevent secondary dust contamination.
  • Perform liquid cooling maintenance only when coolant temperature ≤40℃ to avoid scalding; replenish with matching coolant only, prohibited to mix different fluid types.
  • Wear safety harnesses for high-altitude maintenance on towers/poles, comply with high-altitude operation specifications to prevent falls.
  • Conduct additional special inspections after extreme weather (heavy rain, typhoon, high temperature) to guarantee system integrity.

13. Factory Strength & After-Sales Service

13.1 Factory Capacity & R&D Strength

  • Production Bases: KITOZER operates two manufacturing hubs in Guangzhou (Guangdong) and Suzhou (Jiangsu), covering total land area of 20,000㎡ with 15,000㎡ standardized workshops, annual production capacity of 100,000 sets of base station heat dissipation equipment to fulfill global order demands.
  • R&D Team: 30 core R&D engineers including 5 PhD holders and 15 masters, with over 10 years of dedicated research in base station thermal management technology. The team owns 20 invention patents, 30 utility model patents and leads formulation of 5 industry standards.
  • Production Equipment: Import German CNC machining centers, Japanese vacuum welding equipment, fully automatic heat pipe production lines, micro-channel cold plate processing equipment and intelligent testing instruments (thermal conductivity testers, thermal resistance testers, environmental simulation labs) for fully automated production with machining precision up to 0.01mm.
  • Quality Control: Certified with ISO9001 Quality Management System, ISO14001 Environmental Management System, CE and FCC certifications. Raw materials (aluminum, copper, electronic components) sourced from top international brands (Mitsubishi Japan, Siemens Germany). 100% factory testing covering temperature, thermal resistance, pressure resistance and protection grades to guarantee consistent product quality.
  • Supply Chain Advantages: Long-term strategic cooperation with major domestic aluminum and electronic component manufacturers, bulk spot stock of core raw materials, production lead time 7–15 days for rapid client demand response.

13.2 After-Sales Service Commitments

  1. Warranty Policy All product lines carry a 3-year general warranty; core components (heat pipes, vapor chambers) covered for 5 years. Free repair and component replacement for non-human-induced failures within warranty period, free on-site service available nationwide.
  2. Rapid Response Mechanism Nationwide after-sales service network with 5 regional service centers in Guangdong, Zhejiang, Jiangsu, Sichuan and Beijing. 7×24-hour technical support, remote guidance reply within 30 minutes; on-site service arrives within 48 hours for mainland cities, 72 hours for remote areas.
  3. Free Technical Training Online/offline professional training free of charge covering product principles, installation & commissioning, operation, maintenance and fault troubleshooting; completion certificates issued post-training to enable independent client operation.
  4. Lifelong Customized Technical Support Permanent technical assistance for product upgrades, system renovations and customized solutions; free drawing design and technical optimization to match unique project requirements.
  5. Spare Parts Support Full stock of core spare parts (fans, temperature controllers, sensors, heat pipes) for fast delivery. Preferential pricing offered for spare parts outside warranty period to shorten downtime.
  6. Regular Client Follow-Up Establish dedicated client files with monthly follow-up visits to track equipment operation status, provide maintenance suggestions and collect feedback for continuous product & service optimization.

14. Conclusion

Designed under the core philosophy of “High Efficiency, Energy Saving, Intelligence & Reliability”, KITOZER 4G/5G base station heat dissipation equipment solutions cover all power tiers and full application scenarios for base station thermal management, integrating four core technologies: air cooling, heat pipe cooling, liquid cooling and intelligent control. The product line addresses three major industry pain points of 5G base stations: ultra-high heat flux density, excessive power consumption and poor adaptability to extreme operating environments.

Five core competitive strengths: high-efficiency heat dissipation (energy saving rate ≥40%), wide temperature range (-40℃~+85℃), intelligent control (COP ≥16.15), superior reliability (MTBF ≥80,000 hours) and modular plug-and-play design for rapid deployment. All products pass ISO9001/ISO14001, CE and FCC certifications with stable consistent quality. They have been successfully deployed in over 20 Chinese provinces across more than 1,000 base station projects with proven outstanding energy-saving performance and consistent positive client feedback.

Moving forward, KITOZER will continuously boost R&D investment to make breakthroughs in three key technical directions: ultra-high heat flux density heat dissipation, AI intelligent temperature control and eco-friendly coolant development. The company will further optimize product performance and reduce costs, delivering higher-performance, more efficient and reliable thermal management solutions for global 4G/5G base station construction and energy-saving renovation projects, supporting green low-carbon development of the communications industry.

15. Search Keywords, SEO & Tags

15.1 Core & Long-Tail Search Keywords

  • Core Keywords: 4G base station heat dissipation equipment, 5G base station heat dissipation system, base station heat pipe radiator, base station liquid cooling equipment, KITOZER base station cooling
  • Long-Tail Keywords: 5G macro station heat dissipation solution, energy-saving cooling system for base stations, outdoor base station heat dissipation equipment, BBU liquid cooling system, RRU heat pipe cooling, intelligent temperature control system for base stations, extreme environment base station cooling, base station cooling renovation plan

15.2 SEO Optimization (Title / Meta Description / Keywords)

  • Article Title: 4G/5G Base Station Heat Dissipation Equipment Solution – KITOZER High-Efficiency Energy-Saving Cooling System
  • Meta Description: KITOZER specializes in R&D and manufacturing of 4G/5G base station heat dissipation equipment, providing three tiers of full-scenario cooling solutions including heat pipe radiators, liquid cooling devices and intelligent temperature control systems with high energy efficiency.
  • Keywords: 4G base station heat dissipation equipment, 5G base station heat dissipation system, base station heat pipe radiator, base station liquid cooling equipment, KITOZER base station cooling, energy-saving base station cooling, outdoor base station heat dissipation, BBU liquid cooling, RRU heat pipe cooling

15.3 Tags (Classification Tags & Popular Hashtags)

  • Classification Tags: Base Station Supporting Equipment, Base Station Heat Dissipation Equipment, 5G Communication Equipment, Energy-Saving Equipment, Industrial Thermal Management
  • Popular Hashtags: #5GBaseStationCooling #BaseStationEnergySavingRenovation #HeatPipeCooling #LiquidCooling #KITOZER #CommunicationEquipmentCooling #IntelligentTemperatureControl