Table of Contents
Toggle1. System Overview
4G/5G base station RF modules are core supporting equipment for mobile communication base stations. Serving as the “conversion hub” between baseband signals and over-the-air RF signals, they undertake critical functions including signal frequency conversion, amplification, filtering, and transmit-receive switching, directly determining base station coverage range, communication quality and system capacity.
KITOZER base station RF modules are compatible with all 4G LTE and 5G NR standards, covering mainstream Sub-6GHz frequency bands and high-frequency millimeter wave bands. Adopting Gallium Nitride (GaN) semiconductor technology and highly integrated design, they feature high power, high efficiency, low noise and miniaturization. Suitable for deployment scenarios including macro base stations, distributed base stations and small cell base stations, they can meet differentiated demands of operators for wide-area coverage, deep indoor coverage and industrial private networks, support the implementation of key 5G technologies such as Massive MIMO and beamforming, and facilitate efficient, stable and low-cost construction of 4G/5G networks.

4G/5G Base Station RF Module
2. System Composition
The KITOZER base station RF module system consists of nine core components: RF transceiver unit, power amplification unit, low noise amplification unit, filtering unit, duplexer/combiner unit, RF switch unit, power management unit, control & interface unit, and heat dissipation unit. All units work collaboratively to complete the full process of signal transmission, reception and processing.
- RF Transceiver Unit: The core hub, realizing mutual conversion between baseband IQ signals and RF signals. It integrates up/down frequency conversion, Analog-to-Digital/Digital-to-Analog Conversion (ADC/DAC) and Digital Pre-Distortion (DPD), supporting stable communication with BBU via CPRI/OBSAI protocols.
- Power Amplification Unit (PA): The core of the transmit link. Adopting high-power GaN devices, it amplifies intermediate frequency signals to rated transmit power with high linearity and high Power Added Efficiency (PAE), compatible with high-order modulation schemes such as 256-QAM.
- Low Noise Amplification Unit (LNA): The core of the receive link. It amplifies weak RF signals received by antennas with an ultra-low Noise Figure (NF) design to maximally preserve signal purity and improve receiver sensitivity.
- Filtering Unit: Comprises transmit filters, receive filters and cavity filters. The transmit side filters out harmonics and spurious signals, while the receive side suppresses out-of-band interference and image frequencies to guarantee Adjacent Channel Leakage Ratio (ACLR) and signal purity.
- Duplexer/Combiner Unit: Duplexers isolate transmit and receive signals of a single antenna to avoid interference; combiners support multi-band and multi-channel signal combination, adapting to multi-standard co-site deployment.
- RF Switch Unit: Manufactured with SOI technology, it realizes transmit-receive channel switching, frequency band selection and beam scheduling, featuring low insertion loss, high isolation and fast switching speed.
- Power Management Unit: Accepts wide-range DC -48V input, provides multi-stage voltage regulation and overvoltage/overcurrent/overheating protection with low power consumption design to ensure long-term stable operation of modules.
- Control & Interface Unit: Integrated with MCU control chips, it supports local debugging and remote network management monitoring, equipped with optical ports, electrical ports and RS485 interfaces. Compatible with O-RAN architecture, it enables flexible configuration of frequency bands, power and channel quantities.
- Heat Dissipation Unit: Constructed with die-cast aluminum alloy housing and high-efficiency heat dissipation fins. High-end models are equipped with intelligent temperature-controlled fans, adapting to a wide operating temperature range of -40℃ ~ +55℃ to resolve heat dissipation challenges of high-power equipment.

Internal Circuit of RF Module
3. System Classification
KITOZER base station RF modules are classified across five dimensions: communication standard, frequency band, output power, channel quantity and deployment scenario, covering low, medium and high-grade configurations to fit diverse construction requirements.
3.1 Classification by Communication Standard
- 4G LTE RF Modules: Support LTE FDD/TDD standards, covering mainstream bands 1.8GHz, 2.1GHz and 2.6GHz with output power ranging from 20W to 60W, applicable to 4G macro stations and indoor distribution systems.
- 5G NR RF Modules:
- Sub-6GHz Band: Supports bands n1/n3/n5/n7/n8/n20/n34/n38/n41/n78/n79, power 40W~120W, suitable for 5G macro stations and distributed base stations.
- Millimeter Wave Band: Supports bands n257/n258/n260/n261, power 10W~30W, integrated with beamforming antennas for high-density hotspot coverage of 5G.
- 4G/5G Dual-Mode RF Modules: Fully compatible with all 4G/5G standards and support concurrent multi-band operation, power 30W~100W, ideal for 4G/5G co-site upgrade scenarios to reduce construction costs.
3.2 Classification by Output Power

- Low-Power Modules (10W~30W): Compact size and low power consumption, suitable for indoor small cell base stations, enterprise private networks, underground parking lots and elevator coverage.
- Medium-Power Modules (40W~80W): Balanced power and volume, applicable to urban macro base stations, suburban coverage and industrial parks for medium-range coverage demands.
- High-Power Modules (100W~200W): GaN high-power solution with wide coverage and strong penetration, designed for rural, remote and wide-area coverage scenarios.
3.3 Classification by Channel Quantity
- Single Channel (1T1R): Basic configuration with low cost, for narrowband coverage and NB-IoT IoT scenarios.
- Dual Channel (2T2R): Mainstream configuration supporting MIMO technology to boost spectrum efficiency, used for standard 4G/5G coverage.
- Four Channel (4T4R): Enhanced configuration enabling high-order MIMO and increased system capacity, applicable to high-density urban coverage and 5G hotspots.
- Eight Channels & Above (8T8R/16T16R): High-end configuration supporting Massive MIMO and beamforming to meet demands of ultra-wide bandwidth and ultra-high capacity for 5G.
3.4 Classification by Deployment Scenario

Field Installation of RF Module
- Macro Base Station RF Modules (RRU): Outdoor type with IP65 protection grade, designed for tower-mounted installation and outdoor wide-area macro coverage.
- Distributed RF Modules (pRRU): Miniaturized and lightweight, suitable for indoor distribution systems and building coverage with fiber remote deployment support.
- Integrated RF Modules: Integrated with antennas, RF circuits and power supply, plug-and-play for small cell base stations, emergency communication and temporary coverage scenarios.
4. System Schematic Diagram
Signal Flow Explanation
- Downlink: Baseband IQ signals output by BBU are transmitted to the RF transceiver unit via the control & interface unit, completing digital-to-analog conversion and up-conversion to intermediate frequency signals. After amplification to rated power by the power amplification unit, signals are filtered to remove spurious waves by the transmit filtering unit, isolated by the duplexer/combiner unit and finally transmitted through the RF antenna.
- Uplink: Weak RF signals received by the antenna are isolated by the duplexer/combiner unit, filtered by the receive filtering unit and amplified by the low noise amplification unit. The RF transceiver unit then performs down-conversion and analog-to-digital conversion to restore baseband signals, which are transmitted back to the BBU.
- The power management unit supplies stable power to all sub-units, while the control & interface unit realizes parameter configuration, status monitoring and remote network management functions.
5. Full System Configuration List (Low/Medium/High Grade)
5.1 Low-Grade Configuration List (Indoor Small Cell / Enterprise Private Network)

Tower Installation Effect of RF Module
è¡¨æ ¼
| No. | Product Name | Model | Technical Specs | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | 4G/5G Dual-Mode RF Module (1T1R/20W) | KITOZER-RF-L20-1T1R | Standard: 4G LTE/5G NR; Bands: n1/n3/n5/n8; Power:20W; Channel:1T1R; NF≤1.5dB; ACLR≤-45dBc; Interface:CPRI; Protection:IP54; Dimension:200×150×50mm; Weight:2.5kg | 1 | Set | KITOZER | Indoor wall/tower mount |
| 2 | RF Power Module (-48V/5A) | KITOZER-PWR-L5 | Input:AC 220V±10%; Output:DC -48V/5A; Efficiency≥90%; Protection:OV/OC/short circuit; Dimension:150×120×40mm; Weight:1.2kg | 1 | Set | KITOZER | Power supply for RF module |
| 3 | Indoor Omni Antenna (2dBi) | KITOZER-ANT-L2 | Bands:1710-2690MHz/3300-3800MHz; Gain:2dBi; Polarization:Vertical; Connector:N-type; Dimension:Φ80×200mm; Weight:0.8kg | 1 | Set | KITOZER | Indoor full coverage |
| 4 | RF Feeder Cable (N-type,5m) | KITOZER-FEED-L5 | Impedance:50Ω; Frequency:DC-6GHz; Attenuation≤0.3dB/m; Connector:N-male; Length:5m; Material:Copper core+shield layer | 1 | Pc | KITOZER | Connect RF module and antenna |
| 5 | Low-Grade Installation Accessory Kit | KITOZER-ACC-L | Wall bracket, expansion bolt, cable tie, waterproof adhesive strip | 1 | Set | KITOZER | Installation & fixing |
5.2 Medium-Grade Configuration List (Urban Macro Base Station / Industrial Park)
è¡¨æ ¼
| No. | Product Name | Model | Technical Specs | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | 5G Sub-6GHz RF Module (4T4R/60W) | KITOZER-RF-M60-4T4R | Standard:5G NR/4G LTE; Bands:n3/n7/n38/n41/n78; Power:60W per channel; Channel:4T4R; NF≤1.2dB; ACLR≤-48dBc; EVM≤2.8% (256QAM); Interface:CPRI/OBSAI; Protection:IP65; Dimension:350×250×80mm; Weight:6.5kg | 1 | Set | KITOZER | Outdoor tower/cabinet mount |
| 2 | RF Power Module (-48V/10A) | KITOZER-PWR-M10 | Input:AC 220V±15% / DC -48V; Output:DC -48V/10A; Efficiency≥93%; Protection:OV/OC/OT/short circuit; Dimension:200×150×50mm; Weight:2.8kg | 1 | Set | KITOZER | Wide-temperature outdoor power supply |
| 3 | 4-Channel RF Combiner | KITOZER-COM-M4 | Bands:1710-3800MHz; Channel:4; Insertion loss≤0.5dB; Isolation≥25dB; Power capacity:100W; Connector:N-type; Dimension:180×120×60mm; Weight:1.5kg | 1 | Set | KITOZER | Multi-band signal combination |
| 4 | Directional Panel Antenna (15dBi) | KITOZER-ANT-M15 | Bands:1710-2690MHz/3300-3800MHz; Gain:15dBi; Polarization:±45° dual-polarized; Horizontal beamwidth:65°; Vertical beamwidth:12°; Connector:4×N-type; Dimension:1200×200×80mm; Weight:8kg | 1 | Set | KITOZER | Urban directional coverage |
| 5 | RF Feeder Cable (DIN-type,10m) | KITOZER-FEED-M10 | Impedance:50Ω; Frequency:DC-8GHz; Attenuation≤0.2dB/m; Connector:DIN-male; Length:10m; Material:Oxygen-free copper+double shield | 4 | Pc | KITOZER | 4-channel RF connection |
| 6 | RF & Power Surge Protector | KITOZER-SPD-M | RF SPD:Response time≤1ns, discharge current≤20kA; Power SPD:Protection voltage≤600V; Connector:N-type/Terminal; Protection:IP65; Dimension:150×100×50mm; Weight:1.8kg | 2 | Set | KITOZER | Outdoor lightning protection |
| 7 | Medium-Grade Installation Accessory Kit | KITOZER-ACC-M | Tower bracket, hoop, waterproof connector, grounding flat iron, cable tie | 1 | Set | KITOZER | Outdoor installation & fixing |
5.3 High-Grade Configuration List (Rural Wide-Area Coverage / 5G Hotspot / Millimeter Wave Scenarios)
è¡¨æ ¼
| No. | Product Name | Model | Technical Specs | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | 5G Sub-6GHz High-Power RF Module (8T8R/120W) | KITOZER-RF-H120-8T8R | Standard:Multi-mode 5G NR/4G LTE; Bands:n1/n3/n7/n38/n41/n78/n79; Power:120W per channel; Channel:8T8R; NF≤1.0dB; ACLR≤-50dBc; EVM≤2.5% (256QAM); DPD supported; Interface:CPRI-7.2a/O-RAN; Protection:IP67; Dimension:450×350×100mm; Weight:12kg | 1 | Set | KITOZER | Rural wide-area coverage |
| 2 | 5G Millimeter Wave RF Module (2T2R/20W) | KITOZER-RF-H20-2T2R-MMW | Standard:5G NR mmWave; Bands:n257/n258; Power:20W per channel; Channel:2T2R; NF≤2.0dB; ACLR≤-40dBc; Beamforming supported; Interface:O-RAN; Protection:IP65; Dimension:300×250×80mm; Weight:5.8kg | 1 | Set | KITOZER | 5G high-frequency hotspot coverage |
| 3 | RF Power Module (-48V/20A) | KITOZER-PWR-H20 | Input:AC 110/220V±20% / DC -48V; Output:DC -48V/20A; Efficiency≥95%; Protection:OV/OC/OT/short circuit/lightning; Dimension:250×200×60mm; Weight:4.5kg | 1 | Set | KITOZER | Stable power supply for high-power equipment |
| 4 | 8-Channel RF Duplexer | KITOZER-DUP-H8 | Bands:1710-3800MHz; Channel:8; Insertion loss≤0.4dB; Isolation≥30dB; Power capacity:150W; Connector:DIN-type; Dimension:250×180×80mm; Weight:3.2kg | 1 | Set | KITOZER | Transmit-receive signal isolation |
| 5 | High-Suppression Cavity Filter | KITOZER-FIL-H | Band:3300-3800MHz; Passband loss≤0.3dB; Out-of-band suppression≥80dB@±10MHz; Power capacity:200W; Connector:DIN-type; Dimension:200×150×100mm; Weight:4.0kg | 1 | Set | KITOZER | Spurious interference suppression |
| 6 | High-Gain Directional Antenna (20dBi) | KITOZER-ANT-H20 | Bands:1710-2690MHz/3300-3800MHz; Gain:20dBi; Polarization:±45° dual-polarized; Horizontal beamwidth:55°; Vertical beamwidth:10°; Connector:8×DIN-type; Dimension:1500×250×100mm; Weight:12kg | 1 | Set | KITOZER | Long-distance wide-area coverage |
| 7 | Millimeter Wave Panel Antenna (25dBi) | KITOZER-ANT-H25-MMW | Band:24.5-27.5GHz; Gain:25dBi; Polarization:Linear; Beamwidth:8°; Connector:2×2.92mm; Dimension:200×200×50mm; Weight:2.5kg | 1 | Set | KITOZER | Millimeter wave hotspot coverage |
| 8 | RF Feeder Cable (DIN-type,20m) | KITOZER-FEED-H20 | Impedance:50Ω; Frequency:DC-12GHz; Attenuation≤0.15dB/m; Connector:DIN-male; Length:20m; Material:Oxygen-free copper+triple shield+armored | 8 | Pc | KITOZER | 8-channel RF connection |
| 9 | Intelligent Temperature Control Heat Dissipation Unit | KITOZER-COOL-H | Voltage:DC -48V; Power:50W; Adjustable wind speed; Temp trigger:Start@40℃ / Stop@30℃; Protection:IP65; Dimension:200×150×60mm; Weight:3.0kg | 1 | Set | KITOZER | Heat dissipation for high-power modules |
| 10 | High-Grade Lightning Protection & Grounding Kit | KITOZER-SPD-H | Includes 8-channel RF SPD, power SPD, grounding copper bar, lightning cable, equipotential connector; Discharge current≤40kA; Protection voltage≤500V; Protection:IP67 | 1 | Set | KITOZER | Comprehensive lightning protection |
| 11 | High-Grade Installation Accessory Kit | KITOZER-ACC-H | High-strength tower bracket, stainless steel hoop, waterproof sealed connector, heavy-duty cable tie, grounding terminal, hoisting fitting | 1 | Set | KITOZER | Heavy-duty outdoor installation & fixing |
6. Full Product Technical Parameters
6.1 4G/5G Dual-Mode RF Module (KITOZER-RF-L20-1T1R)

Base Station Monitoring Command Center
- Communication Standard: 4G LTE FDD/TDD, 5G NR Sub-6GHz
- Operating Bands: n1 (1920-1980MHz), n3 (1710-1785MHz), n5 (889-909MHz), n8 (904-915MHz)
- Transmit Power: 20W (43dBm) ±1dB
- Transmit-Receive Channel: 1T1R
- Transmit Indicators: Gain ≥40dB; Linearity ≤0.5dB; ACLR ≤-45dBc@5MHz; Spurious Emission ≤-36dBm@9kHz-1GHz
- Receive Indicators: Noise Figure ≤1.5dB; Gain ≥30dB; Sensitivity ≤-95dBm/200kHz; Input IP3 ≥+20dBm
- Interfaces: CPRI v6.0, SMA RF port, RS485 debug port
- Power Supply: DC -48V±10%, Current ≤2A
- Environment: Operating temp -30℃~+50℃, Storage temp -40℃~+70℃, Humidity 5%~95% (non-condensing)
- Protection Grade: IP54
- Dimension: 200×150×50mm; Weight:2.5kg

Roof Base Station Project Site
6.2 5G Sub-6GHz RF Module (KITOZER-RF-M60-4T4R)
- Communication Standard: Multi-mode 5G NR & 4G LTE
- Operating Bands: n3, n7, n38, n41, n78
- Transmit Power: 60W (47.8dBm) ±1dB per channel
- Channel:4T4R
- Transmit Indicators: Gain ≥45dB; Linearity ≤0.3dB; ACLR ≤-48dBc@10MHz; EVM ≤2.8% (256QAM); Spurious Emission ≤-40dBm@1-12.75GHz
- Receive Indicators: NF ≤1.2dB; Gain ≥35dB; Sensitivity ≤-98dBm/100MHz; Input IP3 ≥+23dBm
- Interfaces: CPRI v7.0, OBSAI, DIN RF port, Gigabit Ethernet
- Power Supply: DC -48V±15%, Current ≤5A
- Environment: Operating temp -40℃~+55℃, Storage temp -45℃~+75℃, Humidity 5%~95% (non-condensing)
- Protection Grade: IP65
- Dimension:350×250×80mm; Weight:6.5kg

Tower Installation Construction
6.3 5G Sub-6GHz High-Power RF Module (KITOZER-RF-H120-8T8R)
- Standard: Multi-mode 5G NR & 4G LTE, fully compatible with O-RAN architecture
- Bands: n1/n3/n7/n38/n41/n78/n79 (3300-3900MHz)
- Power:120W (50.8dBm) ±1dB per channel; Channel:8T8R
- Transmit Specs: Gain≥50dB, Linearity≤0.2dB, ACLR≤-50dBc@20MHz, EVM≤2.5% (256QAM), DPD enabled (linearity improvement ≥15dB), Spurious≤-45dBm@1-18GHz
- Receive Specs: NF≤1.0dB, Gain≥40dB, Sensitivity≤-100dBm/200MHz, Input IP3≥+25dBm
- Interfaces: CPRI v7.2a, O-RAN 7.2, DIN RF port, 10G Ethernet, RS232 debug port
- Power: DC -48V±20%, Current ≤10A
- Environment: -40℃~+55℃ operating, -50℃~+85℃ storage
- Protection: IP67; Dimension:450×350×100mm; Weight:12kg
6.4 5G Millimeter Wave RF Module (KITOZER-RF-H20-2T2R-MMW)
- Standard:5G NR Millimeter Wave
- Bands:n257 (26500-29500MHz), n258 (24250-27500MHz)
- Power:20W (43dBm) ±1dB per channel; Channel:2T2R
- Transmit Specs: Gain≥35dB, ACLR≤-40dBc@100MHz, EVM≤3.0% (64QAM); Beamforming with ±60° scanning angle via 16-element array
- Receive Specs: NF≤2.0dB, Gain≥25dB, Sensitivity≤-90dBm/1GHz
- Interfaces:O-RAN, 2.92mm RF port, Gigabit Ethernet
- Power:DC -48V±10%, Current≤3A
- Environment: -35℃~+55℃ operating, -40℃~+70℃ storage
- Protection:IP65; Dimension:300×250×80mm; Weight:5.8kg
6.5 RF Power Module Series (KITOZER-PWR-L5/M10/H20)
è¡¨æ ¼
| Model | Input Voltage | Output Voltage/Current | Efficiency | Protection | Dimension(mm) | Weight(kg) |
|---|---|---|---|---|---|---|
| KITOZER-PWR-L5 | AC 220V±10% | DC -48V/5A | ≥90% | OV, OC, Short Circuit | 150×120×40 | 1.2 |
| KITOZER-PWR-M10 | AC 220V±15% / DC -48V | DC -48V/10A | ≥93% | OV, OC, OT, Short Circuit | 200×150×50 | 2.8 |
| KITOZER-PWR-H20 | AC 110/220V±20% / DC -48V | DC -48V/20A | ≥95% | OV, OC, OT, Short Circuit, Lightning | 250×200×60 | 4.5 |
6.6 RF Antenna Series
- Indoor Omni Antenna (KITOZER-ANT-L2): Bands 1710-2690MHz/3300-3800MHz, Gain 2dBi, Vertical polarization, N-type connector
- Directional Panel Antenna (KITOZER-ANT-M15): Gain15dBi, ±45° dual-polarized, 65° horizontal /12° vertical beamwidth, 4×N ports
- High-Gain Directional Antenna (KITOZER-ANT-H20): Gain20dBi, ±45° dual-polarized, 55° horizontal /10° vertical beamwidth, 8×DIN ports
- Millimeter Wave Panel Antenna (KITOZER-ANT-H25-MMW): 24.5-27.5GHz, Gain25dBi, linear polarization, 8° beamwidth, 2×2.92mm ports
6.7 RF Passive Devices (Combiner/Duplexer/Feeder)
- RF Combiner (KITOZER-COM-M4): 4-channel, Insertion loss ≤0.5dB, Isolation≥25dB, Power capacity 100W
- RF Duplexer (KITOZER-DUP-H8):8-channel, Insertion loss≤0.4dB, Isolation≥30dB, Power capacity150W
- Cavity Filter (KITOZER-FIL-H): Passband loss≤0.3dB, Out-of-band suppression≥80dB@±10MHz, Power capacity200W
- RF Feeder Cable (L5/M10/H20): 50Ω impedance, low attenuation, multi-layer shielded armored cable for long-distance transmission
7. Product Application Scope
7.1 RF Module Application Scenarios
- 4G/5G Macro Base Stations: Urban, suburban and rural wide-area coverage, 4G/5G co-site upgrade for operator network construction
- Distributed Base Stations (pRRU): Indoor building coverage, shopping malls, office buildings with fiber remote deployment
- Small Cell Base Stations: Enterprise private networks, campuses, underground parking lots, elevators and tunnel blind zones
- 5G Millimeter Wave Hotspots: High-speed railway stations, airports, stadiums and exhibition centers requiring Gbps ultra-high speed
- Industrial Internet: Smart factories, mines, ports and power grids for low-latency, high-reliability industrial automation and remote monitoring
- Emergency Communication: Rapid temporary coverage for disaster relief and emergency command
- Industry Private Networks: Custom frequency & power communication networks for government, public security, fire protection and water conservancy
7.2 Supporting Product Application Scope
- RF Power Modules: Stable power supply for all KITOZER RF modules under wide temperature indoor & outdoor environments
- RF Antennas: Omni antennas for indoor blind-free coverage; directional high-gain antennas for long-distance rural coverage; mmWave panels for high-traffic hotspots
- RF Passive Devices: Combiners reduce antenna quantity for multi-band coexistence; duplexers isolate transmit/receive signals; filters eliminate out-of-band interference; feeders transmit RF signals with low loss
- Lightning/Heat Dissipation/Mounting Kits: Outdoor lightning surge protection, active cooling for high-power equipment, multi-scenario wall/tower mounting accessories
8. Product Advantages
8.1 Core Functional Features
- Full-Standard Compatibility: Supports all 4G LTE & 5G NR Sub-6GHz/mmWave global operator bands, smooth network upgrade without hardware replacement
- High-Performance Metrics: Adopts GaN high-power semiconductor technology with high efficiency and linearity; ultra-low noise figure improves receiver sensitivity; ACLR & EVM exceed industry standards for superior communication quality
- High Integration: Integrates transceiver, amplification, filtering and control circuits, reducing peripheral components, deployment difficulty and overall cost
- Flexible Configurability: Remote adjustable frequency band, transmit power and channel quantity; O-RAN open architecture compatible with third-party equipment
- Wide-Temperature Industrial Design: Operating temperature range -40℃~+55℃, IP54~IP67 protection grade against wind, rain, dust and humidity for harsh outdoor environments
- Low Power Consumption & Energy Saving: GaN + high-efficiency power design cuts power consumption by over 30% vs traditional silicon-based devices, lowering long-term operator OPEX
8.2 Customization & OEM/ODM Capacity
- Customization Service: Customizable frequency band, output power, channel quantity, interface and appearance for special industry private network demands with one-on-one dedicated technical solution design
- OEM/ODM Manufacturing: Full-chain service including scheme design, hardware & software R&D, testing and mass production for brand OEM and differentiated customized development
- Fast Custom Delivery: Mature product platform with professional R&D team; standard custom orders delivered within 2~4 weeks, supporting small trial batches and mass volume production
8.3 Confidentiality & Spot Inventory Advantages
- Strict Confidentiality Mechanism: NDA signed with all clients; full-process internal confidentiality management covering R&D, production and sales to prevent technical data leakage
- Sufficient Spot Inventory: Standard low/medium-grade RF modules, power supplies, antennas and passive devices stocked for 1~3 day delivery upon order; high-power & mmWave products produced on demand with inventory early warning system to guarantee stable supply
8.4 Technical Advantages of Full Product Line
- RF Modules: GaN efficiency ≥40%, NF ≤1.0dB, DPD improves linearity by ≥15dB, Massive MIMO & beamforming boost system capacity by 3~5 times
- RF Power Supplies: Global wide input voltage, peak efficiency ≥95%, multi-layer safety protection, MTBF ≥100,000 hours with industrial-grade components
- RF Antennas: Gain ranging from 2~25dBi, ultra-wide frequency coverage, VSWR ≤1.5 for minimal signal loss, waterproof outdoor design for long-term stable operation
- RF Passive Devices: Insertion loss ≤0.3dB, isolation ≥25dB, power capacity up to 200W, stable performance from -40℃ to +55℃, all-metal shielding housing with strong anti-interference capability
9. Bid-Winning Control Parameters (Marked with *)
9.1 4G/5G Dual-Mode RF Module (KITOZER-RF-L20-1T1R)
- *Communication Standard: Dual-mode compatible with 4G LTE FDD/TDD & 5G NR Sub-6GHz
- *Operating Bands: Support n1/n3/n5/n8, expandable via customization
- *Transmit Power: 20W (43dBm) ±1dB, adjustable range 30~43dBm
- *Transmit-Receive Channel: 1T1R, MIMO technology supported
- *Noise Figure: ≤1.5dB (@25℃)
- *ACLR: ≤-45dBc@5MHz bandwidth
- *Interfaces: CPRI v6.0, SMA RF port, RS485 debug port
- *Protection Grade: IP54
- *Operating Temperature: -30℃~+50℃
9.2 5G Sub-6GHz RF Module (KITOZER-RF-M60-4T4R)
- *Standard: Multi-mode 5G NR & 4G LTE, O-RAN architecture compatible
- *Bands: n3/n7/n38/n41/n78, expandable custom bands available
- *Power:60W (47.8dBm) ±1dB per channel, adjustable range 35~48dBm
- *Channel:4T4R, high-order MIMO supported
- *NF:≤1.2dB (@25℃)
- *ACLR:≤-48dBc@10MHz bandwidth
- *EVM:≤2.8% under 256QAM modulation
- *Interfaces: CPRI v7.0, OBSAI, DIN RF port, Gigabit Ethernet
- *Protection Grade:IP65
- *Operating Temperature:-40℃~+55℃
9.3 5G Sub-6GHz High-Power RF Module (KITOZER-RF-H120-8T8R)
- *Standard: Multi-mode 4G/5G, fully compliant with O-RAN 7.2 standard
- *Bands: Full bands n1/n3/n7/n38/n41/n78/n79, custom special bands supported
- *Power:120W (50.8dBm) ±1dB per channel, adjustable range 40~51dBm
- *Channel:8T8R, Massive MIMO & beamforming supported
- *NF:≤1.0dB (@25℃)
- *ACLR:≤-50dBc@20MHz bandwidth
- *EVM:≤2.5% under 256QAM modulation
- *DPD: Digital Pre-Distortion function improves linearity by ≥15dB
- *Interfaces: CPRI v7.2a, O-RAN 7.2, DIN RF port, 10G Ethernet, RS232 debug port
- *Protection Grade:IP67
- *Operating Temperature:-40℃~+55℃
9.4 5G Millimeter Wave RF Module (KITOZER-RF-H20-2T2R-MMW)
- *Standard:5G NR millimeter wave standard supported
- *Bands:n257/n258 mainstream millimeter wave bands
- *Power:20W (43dBm) ±1dB per channel, adjustable range 33~43dBm
- *Channel:2T2R, beamforming scanning function supported
- *NF:≤2.0dB (@25℃)
- *ACLR:≤-40dBc@100MHz bandwidth
- *Beam Scanning Angle: ±60°
- *Interfaces:O-RAN, 2.92mm RF port, Gigabit Ethernet
- *Protection Grade:IP65
- *Operating Temperature:-35℃~+55℃
9.5 Full Series RF Power Modules
- *Input Voltage: AC 110/220V±20% or DC -48V±20% (model dependent)
- *Output Voltage: DC -48V±5%
- *Output Current:5A/10A/20A (model dependent)
- *Conversion Efficiency: ≥90% (L5) / ≥93% (M10) / ≥95% (H20)
- *Protection Functions: Automatic OV/OC/OT/short circuit protection
- *Operating Temperature:-40℃~+55℃
- *Protection Grade:IP54 (L5) / IP65 (M10/H20)
9.6 RF Antenna Series
- *Operating Band:1710-3900MHz (Sub-6GHz) or 24.5-27.5GHz (mmWave)
- *Gain:2dBi (indoor) /15dBi (directional) /20dBi (high-gain) /25dBi (mmWave)
- *Polarization: Vertical (indoor) / ±45° dual-polarized (directional) / linear (mmWave)
- *VSWR: ≤1.5 across full frequency band
- *Connector Type:N-type (indoor/directional) / DIN (high-gain) /2.92mm (mmWave)
- *Protection Grade:IP65 (outdoor) /IP54 (indoor)
- *Operating Temperature:-40℃~+55℃
9.7 RF Passive Devices (Combiner/Duplexer/Filter)
- *Operating Band:1710-3800MHz (combiner/duplexer) /3300-3800MHz (filter)
- *Insertion Loss: ≤0.5dB (combiner) / ≤0.4dB (duplexer) / ≤0.3dB (filter)
- *Isolation: ≥25dB (combiner) / ≥30dB (duplexer)
- *Out-of-Band Suppression: ≥80dB@±10MHz (filter)
- *Power Capacity:100W (combiner) /150W (duplexer) /200W (filter)
- *Connector:N-type (combiner) / DIN (duplexer/filter)
- *Protection Grade:IP65
- *Operating Temperature:-40℃~+55℃
10. Complete Product Solutions
10.1 Indoor Small Cell Base Station Solution (Low-Grade)
10.1.1 Solution Overview
Targeting enterprise private networks, office buildings, shopping malls, underground parking lots and elevator blind zones, this lightweight low-grade configuration adopts 1T1R/20W dual-mode RF modules, indoor omni antennas and simplified power supplies. Plug-and-play with rapid low-cost deployment, it eliminates indoor signal blind and weak coverage areas to deliver stable 4G/5G voice and data communication services.
10.1.2 Architecture
BBU (Local/Remote) → Optical Fiber → KITOZER-RF-L20-1T1R RF Module → N-type RF Feeder → KITOZER-ANT-L2 Indoor Omni Antenna → Coverage Area
10.1.3 Advantages
- Easy Deployment: Wall/tower mount design; single technician completes installation within one day without complex construction
- Low Capital Cost: Entry-level configuration cuts equipment investment for small-scale indoor coverage projects
- Uniform Coverage: 360° omni radiation eliminates signal dead spots across multi-room & multi-floor indoor spaces
- Convenient Maintenance: Compact lightweight equipment with simple fault diagnosis and remote network management monitoring support
10.1.4 Applicable Scenarios
SME offices, shopping malls, hotel guest rooms, underground parking lots, campus dormitories and community underground corridors
10.2 Urban Macro Base Station Solution (Medium-Grade)
10.2.1 Overview
Designed for urban, suburban and industrial park medium-range coverage, this standardized medium-grade scheme uses 4T4R/60W Sub-6GHz RF modules, directional panel antennas, combiners and lightning protection kits. Balanced performance and reliability support high-density user access and medium-traffic demand while enabling 4G/5G co-site deployment to boost spectrum efficiency and system capacity.
10.2.2 Architecture
BBU (Equipment Room) → Optical Fiber → KITOZER-RF-M60-4T4R RF Module → DIN Feeder → KITOZER-COM-M4 Combiner → KITOZER-ANT-M15 Directional Panel Antenna → Urban Coverage Zone; Supporting accessories: KITOZER-PWR-M10 Power Supply, KITOZER-SPD-M Surge Protector
10.2.3 Advantages
- Balanced Performance: 60W transmit power +4T4R channels deliver 1~3km coverage radius matching urban medium-range coverage requirements
- Capacity Upgrade: 4-channel MIMO quadruples system capacity to support massive concurrent user connections in dense urban areas
- Strong Anti-Interference: Integrated combiners & filters suppress spurious interference to guarantee cross-cell signal quality
- Outdoor Durability: IP65 protection + lightning surge protection withstands harsh outdoor wind, rain and extreme temperature conditions
10.2.4 Applicable Scenarios
Urban residential districts, commercial streets, county suburbs, industrial parks and highway/railway traffic corridor coverage
10.3 Rural Wide-Area Coverage & 5G Hotspot Solution (High-Grade)
10.3.1 Overview
For rural remote wide-area coverage and high-traffic 5G hotspot scenarios, this premium configuration combines 8T8R/120W Sub-6GHz high-power RF modules, 2T2R/20W millimeter wave modules, high-gain directional antennas, duplexers, cavity filters, active cooling and full lightning protection. High transmit power enables ultra-long coverage range and strong penetration for rural mountainous terrain, while millimeter wave equipment delivers Gbps ultra-high throughput for crowded hotspots.
10.3.2 Architecture
- Rural Wide-Area Link: BBU → Optical Fiber → KITOZER-RF-H120-8T8R Module → DIN Feeder → Duplexer → Cavity Filter → High-Gain Antenna → Rural Coverage Zone
- Millimeter Wave Hotspot Link: BBU → Optical Fiber → KITOZER-RF-H20-2T2R-MMW Module → 2.92mm Feeder → Millimeter Wave Panel Antenna → High-Traffic Hotspot Supporting accessories: KITOZER-PWR-H20 Power Supply, Intelligent Cooling Unit, Full Lightning Protection Kit
10.3.3 Advantages
- Ultra-Long Coverage: 120W high power +20dBi high-gain antenna delivers 5~10km coverage radius ideal for mountainous rural terrain
- Massive Capacity: 8-channel Massive MIMO + beamforming doubles capacity vs 4-channel modules to support dense village concurrent access
- Ultra-High Throughput: Millimeter wave hardware provides Gbps-level transmission speed for high-density hotspot big-traffic services
- Extreme Environment Adaptability: IP67 protection + intelligent temperature control + full lightning protection stable under -40℃~+55℃, resisting strong wind, heavy rain and lightning strikes
10.3.4 Applicable Scenarios
Mountain villages, remote pastoral areas, high-speed rail stations, airports, stadiums, industrial mining ports and emergency wide-area private communication
10.4 Industrial Internet Private Network Solution
10.4.1 Overview
Custom medium/high-grade RF module configuration with industrial-grade antennas, explosion-proof and dust-proof accessories for smart factories, mines, ports and power plants. Low-latency, high-reliability, strong anti-electromagnetic interference industrial design supports automated production, remote equipment control and HD video backhaul for Industry 4.0 applications.
10.4.2 Architecture
Industrial Private Network Core BBU → Optical Fiber → KITOZER RF Module (4T4R/60W or 8T8R/120W) → Industrial Low-Loss Feeder → Industrial Directional/Omni Antenna → Industrial Terminal Equipment (Sensors, PLC, Robots, HD Cameras); Supporting industrial power supplies, surge protectors, explosion-proof cabinets and dust shields
10.4.3 Advantages
- Low Latency & High Reliability: 5G NR air interface latency ≤10ms, connection reliability ≥99.99% to meet real-time industrial control standards
- Strong Anti-Interference: Industrial shielding & filtering design resists mechanical vibration, dust, oil fume and factory electromagnetic noise
- Industrial-Grade Protection: IP65~IP67 rating with customizable explosion-proof, high-temperature and anti-corrosion treatment for harsh factory environments
- Customized Adaptation: Specialized modification for explosion-proof, high-temperature and anti-corrosion requirements across different industrial verticals
10.4.4 Applicable Scenarios
Smart manufacturing robotic production lines, open-pit & underground mine personnel positioning, port container dispatching, power substation monitoring and petrochemical plant explosion-proof communication
11. Product Application Cases
11.1 Indoor Small Cell Case: Indoor Coverage Project for a Grade-A Office Building in Guangzhou
11.1.1 Project Background
A 30-floor Grade-A office tower in Tianhe District, Guangzhou suffered severe 4G/5G blind and weak signal zones in underground parking lots, elevator shafts and low-rise offices, triggering massive user complaints. A full indoor deep coverage upgrade was required to improve mobile communication experience.
11.1.2 Project Scheme
Adopted KITOZER low-grade solution, deploying one set of KITOZER-RF-L20-1T1R module + one indoor omni antenna per floor, with extra equipment added for parking lots and elevators. Total 35 sets connected via fiber remote to the equipment room BBU to achieve 100% blind-free building coverage.
11.1.3 Project Outcomes
- Full building signal strength ≥-75dBm with zero blind/weak signal zones, 100% coverage rate
- Stable throughput: Downlink ≥50Mbps, Uplink ≥10Mbps; clear voice calls without disconnection or stuttering
- User complaints reduced by 95%, greatly improving office staff communication satisfaction
11.2 Urban Macro Station Case: 4G/5G Co-Site Project for a Large Industrial Park in Shenzhen
11.2.1 Background
A 5km² industrial park in Bao’an District, Shenzhen hosts over 200 enterprises and 50,000 employees. Original 4G base stations faced capacity bottlenecks and insufficient 5G coverage, unable to support enterprise high-speed data and industrial internet services. New co-site macro stations were required to boost coverage and capacity.
11.2.2 Scheme
Deployed 3 sets of KITOZER medium-grade solution at park high points: KITOZER-RF-M60-4T4R RF modules + directional panel antennas, matched with medium-grade power supplies, 4-channel combiners and outdoor surge protectors to fully cover the entire industrial zone with 4G/5G co-site capability.
11.2.3 Outcomes
- Coverage radius 2~3km, full park signal strength ≥-80dBm, 100% coverage
- 4T4R MIMO quadruples system capacity to support 50,000 concurrent users without network congestion
- Stable service throughput: 4G downlink ≥100Mbps, 5G downlink ≥500Mbps, fully supporting enterprise high-speed internet, industrial IoT and HD video conferencing
11.3 Rural Wide-Area Case: 5G Coverage Project for Remote Mountain Villages in Eastern Guangdong
11.3.1 Background
Twelve mountain villages spanning 20km² in Eastern Guangdong suffered insufficient cellular coverage: most zones lacked 5G signals and weak 4G service, severely limiting villagers’ daily communication. A high-power long-distance 5G macro station was required for full rural wide-area coverage.
11.3.2 Scheme
Installed two sets of KITOZER high-grade solution at mountain peaks: KITOZER-RF-H120-8T8R high-power modules + high-gain directional antennas, equipped with high-current power supplies, 8-channel duplexers, high-suppression cavity filters, intelligent cooling and full lightning protection kits to cover all 12 mountain villages.
11.3.3 Outcomes
- 8~10km ultra-long coverage radius, all village signal strength ≥-85dBm, 100% coverage
- 5G stable throughput: Downlink ≥300Mbps, Uplink ≥50Mbps, supporting HD video calls and rural live streaming
- Resolved rural communication barriers, facilitating rural e-commerce, distance education and telemedicine to advance rural revitalization
11.4 Millimeter Wave Hotspot Case: High-Speed 5G Coverage Project for a Shanghai High-Speed Railway Station
11.4.1 Background
A major Shanghai high-speed railway station with daily passenger volume of 100,000 faced severe network congestion in waiting halls and platforms during peak hours. Existing Sub-6GHz base stations lacked sufficient capacity, leading to low data rates and poor user experience. Millimeter wave hotspot equipment was deployed to boost throughput and capacity for crowded passenger zones.
11.4.2 Scheme
Installed five sets of KITOZER millimeter wave high-grade solution across waiting halls and platforms: KITOZER-RF-H20-2T2R-MMW millimeter wave RF modules + 25dBi mmWave panel antennas, matched with medium-grade power supplies and outdoor surge protectors to deliver Gbps-level high-speed coverage for core passenger zones.
11.4.3 Outcomes
- 100% coverage of waiting halls and platforms with signal strength ≥-70dBm
- Millimeter wave throughput: Downlink ≥1Gbps, Uplink ≥200Mbps; no network congestion during passenger peak hours, enabling instant HD video and large file downloads
- Greatly improved passenger internet experience and overall station service quality
11.5 Industrial Internet Case: 5G Private Network Project for a Smart Home Appliance Factory in Foshan
11.5.1 Background
A smart appliance manufacturing plant in Foshan deployed industrial robots, PLC controllers, sensors and HD monitoring cameras across production lines. Traditional wired networks suffered complex wiring and high maintenance costs, while legacy wireless networks delivered excessive latency and low reliability incompatible with real-time automated production control. A dedicated low-latency 5G industrial private network was required for full wireless interconnection of workshop equipment.
11.5.2 Scheme
Four sets of KITOZER medium-grade industrial solution were mounted on workshop ceilings: KITOZER-RF-M60-4T4R RF modules + industrial directional antennas, equipped with industrial power supplies, surge protectors and dust shields to build a full 5G industrial private network connecting all production terminal devices.
11.5.3 Outcomes
- Air interface latency ≤8ms, connection reliability ≥99.995%, fully meeting industrial real-time control standards
- Full wireless interconnection of robots, PLCs, sensors and monitoring cameras reduces wiring costs by 80% and simplifies daily equipment maintenance
- Supports real-time automated production line control, HD monitoring and remote equipment maintenance; overall factory production efficiency improved by 30% and equipment fault diagnosis time cut by 50%
12. Product Troubleshooting & Maintenance Guide
12.1 Common Faults & Troubleshooting Procedures
12.1.1 No RF Output from Module
- Symptom: Module powers on normally, no transmit RF power detected at antenna port
- Root Causes: Faulty power supply, damaged internal RF circuit, incorrect parameter configuration, short-circuited antenna/feeder cable
- Troubleshooting Steps:
- Verify input power voltage within rated range; replace power supply for testing
- Check module band, power and channel configuration; restore factory default settings and reconfigure parameters
- Disconnect antenna & feeder cable and test standalone module RF output; zero output indicates damaged internal RF circuit requiring factory repair
- Inspect feeder cable and antenna for breakage/short circuit; replace accessories for verification
12.1.2 Weak Signal & Small Coverage Radius
- Symptom: RF signal exists but signal strength is low, coverage range shrinks and user experience degrades
- Root Causes: Low transmit power setting, insufficient antenna gain, excessive feeder attenuation, module aging, severe external RF interference
- Troubleshooting Steps:
- Adjust module transmit power to rated maximum level
- Check antenna mounting integrity and physical damage; upgrade to higher-gain antenna
- Inspect feeder length, loose/oxidized connectors; shorten cable length or adopt low-loss feeder, re-tighten all RF joints
- Test module gain & noise figure; degraded performance indicates component aging requiring replacement or factory calibration
- Locate external interference sources (nearby base stations, high-power industrial equipment); reassign operating frequency or install extra suppression filters
12.1.3 Signal Interference, Call Stuttering & Connection Dropouts
- Symptom: Signal strength normal but voice calls stutter, data packet loss and disconnections frequently occur
- Root Causes: Adjacent channel interference, excessive spurious emission, poor module linearity, insufficient antenna isolation, damaged feeder shielding layer
- Troubleshooting Steps:
- Cross-check frequency allocation of neighboring base stations; adjust local operating frequency offset to avoid adjacent band overlap
- Test module ACLR & EVM indicators; over-limit metrics require DPD function activation or factory linearity repair
- Adjust antenna mounting spacing to improve isolation; install isolation baffles to eliminate mutual antenna interference
- Inspect feeder shielding integrity and outdoor joint waterproof sealing; replace triple-shielded armored feeder and re-seal all RF connectors
- Install high-suppression cavity filters to eliminate out-of-band spurious interference
12.1.2 Power-On Failure & Repeated Rebooting
- Symptom: Module fails to boot after power input, indicator lights flash abnormally or equipment restarts cyclically
- Root Causes: Abnormal power voltage, insufficient power supply capacity, internal short circuit, blocked heat dissipation, corrupted firmware
- Troubleshooting Steps:
- Measure power input voltage and output current to match module rated specifications; upgrade to higher-capacity power supply
- Inspect cooling system for blocked heat sinks or non-functional cooling fans; clean accumulated dust or replace damaged fans
- Disconnect all external accessories (antenna, feeder, Ethernet cable) and power module standalone; persistent failure indicates internal short circuit or firmware corruption requiring factory repair
- Reconnect peripherals one by one to identify short-circuited external equipment triggering reboot cycles
12.1.5 Remote Network Management Connection Failure
- Symptom: Local debugging accessible but remote monitoring system cannot connect for parameter configuration and status tracking
- Root Causes: Incorrect network IP configuration, damaged Ethernet cable, blocked firewall ports, faulty monitoring server, damaged module Ethernet port
- Troubleshooting Steps:
- Verify module IP, subnet mask and gateway match monitoring server network segment; reconfigure network parameters
- Inspect Ethernet cable and crystal head for breakage or loose contact; replace cable for testing
- Confirm management ports (8080, 22) are unblocked by network firewalls; open required communication ports
- Check monitoring server operation and end-to-end network connectivity; restart server service
- If all above steps pass, module Ethernet port hardware is damaged requiring factory repair
12.2 Routine Maintenance Specifications
12.2.1 Maintenance Cycle
- Daily Inspection: Once per day, check equipment status indicators, power supply, heat dissipation and antenna/feeder appearance
- Monthly Maintenance: Once per month, full equipment performance inspection, surface cleaning, connector fastening and key RF indicator testing
- Quarterly Maintenance: Once per quarter, deep dust cleaning, RF performance calibration, firmware upgrade and lightning protection grounding inspection
- Annual Overhaul: Once per year, full equipment indicator testing, aging component replacement, lightning protection system full inspection and hidden hazard elimination
12.2.2 Daily Inspection Checklist
- Equipment Status: Module & power supply indicators normal without abnormal flashing/alarm; no abnormal odor, noise or overheating
- Power Supply: Input/output voltage/current stable without fluctuation or overload; wiring terminals free of looseness, oxidation and overheating
- Heat Dissipation: Cooling fans operate smoothly without abnormal noise or stall; heat sinks unblocked by dust for unobstructed ventilation
- Antenna & Feeder: Antennas firmly mounted without tilt, breakage or rust; feeder cables intact without extrusion/aging; RF connectors tightly sealed against water ingress and oxidation
- Lightning & Grounding: Surge protector indicators normal without failure alarms; grounding flat iron and cables firmly connected without rust or fracture; total grounding resistance ≤4Ω
- Environment: Equipment surroundings free of obstructions blocking ventilation; ambient temperature & humidity within rated range without water accumulation or corrosive substances
12.2.3 Monthly Maintenance Checklist
- Cleaning: Wipe equipment surface dust and oil stains with dry cloth; brush accumulated dust on heat sinks and cooling fans; remove dirt, bird droppings and rust from antenna surfaces
- Connector Fastening: Re-tighten all RF feeder joints, power terminals and Ethernet crystal heads to eliminate loose contact-induced oxidation
- Performance Testing: Measure module transmit power, gain, noise figure, ACLR and EVM; record data for comparison against factory standard metrics to identify abnormal degradation
- Functional Verification: Log into remote network management platform to verify parameter configuration, real-time status monitoring and fault alarm reporting; test field signal coverage, voice quality and data throughput to guarantee normal service operation
12.2.4 Quarterly Maintenance Checklist
- Deep Cleaning: Disassemble cooling fans and dust shields for thorough decontamination; lubricate fan bearings or replace aging fans
- RF Calibration: Calibrate full RF indicators using spectrum analyzers and power meters to restore equipment to factory standard performance
- Firmware Upgrade: Check official latest firmware version, back up existing configuration and complete upgrade to resolve known software bugs and optimize performance
- Lightning Grounding Inspection: Test surge protector performance and replace failed units; re-measure grounding resistance to ensure ≤4Ω; derust and re-fasten all grounding connection points with anti-rust treatment
12.2.5 Annual Overhaul Checklist
- Full Performance Testing: Complete indicator measurement for all modules, power supplies, antennas and passive devices to evaluate equipment aging degree and generate official test reports
- Aging Component Replacement: Swap out degraded hardware including cooling fans, feeder cables, RF connectors and surge protectors to prevent sudden service outages
- Full Lightning Protection Inspection: Comprehensive performance test of surge protectors, grounding grids and lightning cables; repair damaged components to guarantee reliable lightning strike resistance
- Hidden Hazard Rectification: Full risk audit of mounting, power supply, heat dissipation and grounding systems; immediately resolve identified safety hazards to eliminate equipment failure risks
12.3 Maintenance Safety Precautions
- Safety Priority: All maintenance operations must be performed by certified professional technicians complying with industry safety operating standards; outdoor tower maintenance requires fall protection, electric shock prevention and lightning protection gear; insulated gloves mandatory for live circuit operation to avoid short circuit and electric shock
- Power Cut Operation: Cut off equipment power supply and wait for full capacitor discharge before disassembly, cleaning or connector tightening to prevent electric shock and hardware burnout
- Waterproof & Moisture-Proof: Avoid water or moisture ingress into equipment and RF connectors during maintenance; reapply waterproof sealing treatment for all outdoor joints post-maintenance to block rainwater intrusion
- Gentle Handling: Lift and transport equipment with care to avoid impact and vibration damaging internal precision RF components
- Record Archiving: Log all maintenance, troubleshooting and repair records including date, technician, operation content, test results and replaced spare parts to build full lifecycle equipment archives for later traceability and failure analysis
- Spare Parts Reserve: Stock common replacement components (power supplies, feeder cables, RF connectors, surge protectors, cooling fans) to enable fast equipment swap and minimize service downtime during faults
13. Factory Strength & After-Sales Service
13.1 Factory Production Capacity & Technical Strength
13.1.1 Production Scale & Output Capacity
KITOZER operates a 20,000 m² modern manufacturing base in Guangzhou dedicated to R&D, production and sales of 4G/5G base station RF modules and supporting equipment. The factory is equipped with 10 automated production lines featuring SMT placement machines, reflow ovens, wave soldering equipment, ATE automatic test stations, spectrum analyzers and RF power meters. Annual production capacity reaches 500,000 RF modules and 1,000,000 sets of supporting accessories to fulfill mass global customer orders. Standard orders are delivered within 7~15 days, customized orders within 2~4 weeks.
13.1.2 R&D Technical Competency
The company’s 50-person professional R&D team includes 5 PhD holders and 20 master’s engineers with over 10 years of average RF communication industry experience. Long-term industry-university-research cooperation is established with University of Electronic Science and Technology of China and South China University of Technology to conduct forward-looking research on GaN RF technology, 5G Massive MIMO and millimeter wave communication. Over 50 patents have been filed (20 invention patents, 30 utility model patents) with fully independent intellectual property rights, core technology reaching international advanced standards. Annual R&D investment accounts for over 15% of total revenue to continuously launch upgraded new products and maintain technological leadership.
13.1.3 Quality Control System
Full compliance with ISO9001 Quality Management System, ISO14001 Environmental Management System and ISO45001 Occupational Health & Safety Management System standards, implementing full-process quality control covering raw material procurement, production processing, finished product testing, factory inspection and after-sales maintenance.
- Raw Material Inspection: Rigorous supplier screening; core components sourced from top international brands (Qorvo/ADI GaN chips, Murata/Yageo passive components) with 100% incoming testing to reject defective raw materials
- In-Line Production Control: Fully automated assembly with 100% real-time online testing at key processes to detect production defects instantly
- Finished Product Aging Test: Every equipment unit undergoes 72-hour continuous aging, high-low temperature cycling, vibration and full RF indicator testing before factory release to guarantee stable reliability
- Quality Targets: Factory pass rate ≥99.9%, customer complaint rate ≤0.1%, equipment MTBF ≥100,000 hours
13.1.4 Supply Chain & Global Delivery Capacity
Globalized stable supply chain with long-term strategic cooperation agreements with core component vendors to avoid raw material shortage risks. Complete warehousing and logistics system stocks standard product lines for 1~3 day spot delivery upon order confirmation. Long-term partnerships with SF Express, Deppon Logistics and COSCO Shipping deliver nationwide domestic shipments within 3~7 days and global international shipments within 7~15 days. Flexible production scheduling prioritizes urgent mass orders to guarantee on-time delivery.
13.2 After-Sales Service System
13.2.1 Service Philosophy
Adhering to the service tenet of “Customer First, Quality Oriented, Rapid Response, Professional Support”, we provide full-lifecycle after-sales service for global clients covering product design, manufacturing, delivery, installation commissioning, routine maintenance, fault repair and technical upgrades, ensuring stable equipment operation and supporting customer business success.
15. Search Keywords & SEO Tag System
15.1 Core High-Weight Primary Keywords
Base Station RF Module, 4G Base Station RF Module, 5G Base Station RF Module, KITOZER Base Station RF Module, Radio Remote Unit (RRU)
15.2 High-Conversion Long-Tail Procurement Keywords
4G/5G Base Station RF Module Solution, Custom Base Station RF Module Manufacturer, 5G Macro Base Station RF Module Factory, Indoor Distribution RF Module, High-Power Base Station RF Module, Industrial Private Network RF Module, OEM/ODM Base Station RF Module, Base Station RF Module Maintenance Guide, Base Station RF Module Configuration List, Lai’an Intelligent RF Module
15.3 Broad Industry Traffic Keywords
5G Base Station Supporting Equipment, Communication Base Station RF Unit, Base Station RF Front-End Module, Massive MIMO RF Module, Sub-6GHz RF Module, Millimeter Wave RF Module, Base Station Power Amplifier, Base Station Low Noise Amplifier, Communication RF Components, 5G Small Cell RF Unit
15.4 Brand Exclusive Keywords
KITOZER, Lai’an Intelligent, Guangzhou Lai’an Intelligence, KITOZER RF Module, Lai’an Intelligent 5G Solutions
15.5 Search Suggestion & Related Search Keywords
What is a base station RF module, working principle of base station RF module, base station RF module technical parameters, top base station RF module manufacturers, base station RF module price, base station RF module installation guide, base station RF module selection guide, 5G base station RF module industry standards, difference between RRU and RF module
15.6 SEO Optimization Tag Architecture
- Core Page Meta Tags
- H1 Tag (Unique): KITOZER 4G/5G Base Station RF Module Complete Solution
- H2 Tags: System Overview | System Composition | System Classification | Configuration List | Technical Parameters | Application Scope | Product Advantages | Bid-Winning Control Parameters | Industry Solutions | Application Cases | Fault Troubleshooting & Maintenance | Factory Strength & After-Sales Service
- H3 Tags: Subdivided by Low/Medium/High Grade, Frequency Band/Power/Channel, Deployment Scenarios
- Internal Link Anchor Text Tags Anchor Texts: Base Station RF Module, 5G Base Station Supporting Equipment, KITOZER RF Module, Base Station RF Module Manufacturer, Complete Solutions, Application Cases, Technical Specifications Internal Link Target Pages: Homepage, Product Center, Solution Center, Case Library, Technical Support, About Us, Contact Us